Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Magn Reson Med ; 91(5): 1936-1950, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38174593

RESUMEN

PURPOSE: Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS: Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION: The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.


Asunto(s)
Corazón , Miocardio , Humanos , Animales , Porcinos , Corazón/diagnóstico por imagen , Respiración , Contencion de la Respiración , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética , Imagenología Tridimensional/métodos
2.
Nanotechnology ; 28(18): 185403, 2017 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-28397707

RESUMEN

Ocean waves are one of the cleanest and most abundant energy sources on earth, and wave energy has the potential for future power generation. Triboelectric nanogenerator (TENG) technology has recently been proposed as a promising technology to harvest wave energy. In this paper, a theoretical study is performed on a duck-shaped TENG wave harvester recently introduced in our work. To enhance the design of the duck-shaped TENG wave harvester, the mechanical and electrical characteristics of the harvester's overall structure, as well as its inner configuration, are analyzed, respectively, under different wave conditions, to optimize parameters such as duck radius and mass. Furthermore, a comprehensive hybrid 3D model is introduced to quantify the performance of the TENG wave harvester. Finally, the influence of different TENG parameters is validated by comparing the performance of several existing TENG wave harvesters. This study can be applied as a guideline for enhancing the performance of TENG wave energy harvesters.

3.
ArXiv ; 2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-37664410

RESUMEN

Dynamic contrast-enhanced (DCE) cardiac magnetic resonance imaging (CMRI) is a widely used modality for diagnosing myocardial blood flow (perfusion) abnormalities. During a typical free-breathing DCE-CMRI scan, close to 300 time-resolved images of myocardial perfusion are acquired at various contrast "wash in/out" phases. Manual segmentation of myocardial contours in each time-frame of a DCE image series can be tedious and time-consuming, particularly when non-rigid motion correction has failed or is unavailable. While deep neural networks (DNNs) have shown promise for analyzing DCE-CMRI datasets, a "dynamic quality control" (dQC) technique for reliably detecting failed segmentations is lacking. Here we propose a new space-time uncertainty metric as a dQC tool for DNN-based segmentation of free-breathing DCE-CMRI datasets by validating the proposed metric on an external dataset and establishing a human-in-the-loop framework to improve the segmentation results. In the proposed approach, we referred the top 10% most uncertain segmentations as detected by our dQC tool to the human expert for refinement. This approach resulted in a significant increase in the Dice score (p<0.001) and a notable decrease in the number of images with failed segmentation (16.2% to 11.3%) whereas the alternative approach of randomly selecting the same number of segmentations for human referral did not achieve any significant improvement. Our results suggest that the proposed dQC framework has the potential to accurately identify poor-quality segmentations and may enable efficient DNN-based analysis of DCE-CMRI in a human-in-the-loop pipeline for clinical interpretation and reporting of dynamic CMRI datasets.

4.
Med Image Comput Comput Assist Interv ; 14222: 453-462, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38204763

RESUMEN

Dynamic contrast-enhanced (DCE) cardiac magnetic resonance imaging (CMRI) is a widely used modality for diagnosing myocardial blood flow (perfusion) abnormalities. During a typical free-breathing DCE-CMRI scan, close to 300 time-resolved images of myocardial perfusion are acquired at various contrast "wash in/out" phases. Manual segmentation of myocardial contours in each time-frame of a DCE image series can be tedious and time-consuming, particularly when non-rigid motion correction has failed or is unavailable. While deep neural networks (DNNs) have shown promise for analyzing DCE-CMRI datasets, a "dynamic quality control" (dQC) technique for reliably detecting failed segmentations is lacking. Here we propose a new space-time uncertainty metric as a dQC tool for DNN-based segmentation of free-breathing DCE-CMRI datasets by validating the proposed metric on an external dataset and establishing a human-in-the-loop framework to improve the segmentation results. In the proposed approach, we referred the top 10% most uncertain segmentations as detected by our dQC tool to the human expert for refinement. This approach resulted in a significant increase in the Dice score (p < 0.001) and a notable decrease in the number of images with failed segmentation (16.2% to 11.3%) whereas the alternative approach of randomly selecting the same number of segmentations for human referral did not achieve any significant improvement. Our results suggest that the proposed dQC framework has the potential to accurately identify poor-quality segmentations and may enable efficient DNN-based analysis of DCE-CMRI in a human-in-the-loop pipeline for clinical interpretation and reporting of dynamic CMRI datasets.

5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4045-4051, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892118

RESUMEN

Quantitative analysis of dynamic contrast-enhanced cardiovascular MRI (cMRI) datasets enables the assessment of myocardial blood flow (MBF) for objective evaluation of ischemic heart disease in patients with suspected coronary artery disease. State-of-the-art MBF quantification techniques use constrained deconvolution and are highly sensitive to noise and motion-induced errors, which can lead to unreliable outcomes in the setting of high-resolution MBF mapping. To overcome these limitations, recent iterative approaches incorporate spatial-smoothness constraints to tackle pixel-wise MBF mapping. However, such iterative methods require a computational time of up to 30 minutes per acquired myocardial slice, which is a major practical limitation. Furthermore, they cannot enforce robustness to residual nonrigid motion which can occur in clinical stress/rest studies of patients with arrhythmia. We present a non-iterative patch-wise deep learning approach for pixel-wise MBF quantification wherein local spatio-temporal features are learned from a large dataset of myocardial patches acquired in clinical stress/rest cMRI studies. Our approach is scanner-independent, computationally efficient, robust to noise, and has the unique feature of robustness to motion-induced errors. Numerical and experimental results obtained using real patient data demonstrate the effectiveness of our approach.Clinical Relevance- The proposed patch-wise deep learning approach significantly improves the reliability of high-resolution myocardial blood flow quantification in cMRI by improving its robustness to noise and nonrigid myocardial motion and is up to 300-fold faster than state-of-the-art iterative approaches.


Asunto(s)
Enfermedad de la Arteria Coronaria , Aprendizaje Profundo , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4072-4078, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892124

RESUMEN

In this work, we develop a patch-level training approach and a task-driven intensity-based augmentation method for deep-learning-based segmentation of motion-corrected perfusion cardiac magnetic resonance imaging (MRI) datasets. Further, the proposed method generates an image-based uncertainty map thanks to a novel spatial sliding-window approach used during patch-level training, hence allowing for uncertainty quantification. Using the quantified uncertainty, we detect the out-of-distribution test data instances so that the end-user can be alerted that the test data is not suitable for the trained network. This feature has the potential to enable a more reliable integration of the proposed deep learning-based framework into clinical practice. We test our approach on external MRI data acquired using a different acquisition protocol to demonstrate the robustness of our performance to variations in pulse-sequence parameters. The presented results further demonstrate that our deep-learning image segmentation approach trained with the proposed data-augmentation technique incorporating spatiotemporal (2D+time) patches is superior to the state-of-the-art 2D approach in terms of generalization performance.


Asunto(s)
Aprendizaje Profundo , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Perfusión , Incertidumbre
7.
IEEE Trans Biomed Eng ; 68(10): 2940-2947, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33531296

RESUMEN

OBJECTIVE: In biomanufacturing there is a need for quantitative methods to map cell viability and density inside 3D bioreactors to assess health and proliferation over time. Recently, noninvasive MRI readouts of cell density have been achieved. However, the ratio of live to dead cells was not varied. Herein we present an approach for measuring the viability of cells embedded in a hydrogel independently from cell density to map cell number and health. METHODS: Independent quantification of cell viability and density was achieved by calibrating the 1H magnetization transfer- (MT) and diffusion-weighted NMR signals to samples of known cell density and viability using a multivariate approach. Maps of cell viability and density were generated by weighting NMR images by these parameters post-calibration. RESULTS: Using this method, the limits of detection (LODs) of total cell density and viable cell density were found to be 3.88 ×108 cells · mL -1· Hz -1/2 and 2.36 ×109 viable cells · mL -1· Hz -1/2 respectively. CONCLUSION: This mapping technique provides a noninvasive means of visualizing cell viability and number density within optically opaque bioreactors. SIGNIFICANCE: We anticipate that such nondestructive readouts will provide valuable feedback for monitoring and controlling cell populations in bioreactors.


Asunto(s)
Hidrogeles , Imagen por Resonancia Magnética , Recuento de Células , Supervivencia Celular , Espectroscopía de Resonancia Magnética
8.
IEEE Trans Biomed Eng ; 66(3): 821-830, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30028689

RESUMEN

OBJECTIVE: For tissue engineering, there is a need for quantitative methods to map cell density inside three-dimensional (3-D) bioreactors to assess tissue growth over time. The current cell mapping methods in 2-D cultures are based on optical microscopy. However, optical methods fail in 3-D due to increased opacity of the tissue. We present an approach for measuring the density of cells embedded in a hydrogel to generate quantitative maps of cell density in a living, 3-D tissue culture sample. METHODS: Quantification of cell density was obtained by calibrating the 1H T2, magnetization transfer (MT) and diffusion-weighted nuclear magnetic resonance (NMR) signals to samples of known cell density. Maps of cell density were generated by weighting NMR images by these parameters post-calibration. RESULTS: The highest sensitivity weighting arose from MT experiments, which yielded a limit of detection (LOD) of [Formula: see text] cells/mL/ √{Hz} in a 400 MHz (9.4 T) magnet. CONCLUSION: This mapping technique provides a noninvasive means of visualizing cell growth within optically opaque bioreactors. SIGNIFICANCE: We anticipate that such readouts of tissue culture growth will provide valuable feedback for controlled cell growth in bioreactors.


Asunto(s)
Recuento de Células/métodos , Hidrogeles/química , Imagenología Tridimensional/métodos , Espectroscopía de Resonancia Magnética/métodos , Reactores Biológicos , Células Cultivadas , Células HEK293 , Humanos , Saccharomyces cerevisiae/citología , Procesamiento de Señales Asistido por Computador , Ingeniería de Tejidos
9.
IEEE Trans Biomed Eng ; 64(1): 61-69, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-26955013

RESUMEN

Tissue engineering (TE) approaches that involve seeding cells into predetermined tissue scaffolds ignore the complex environment where the material properties are spatially inhomogeneous and evolve over time. We present a new approach for controlling mechanical forces inside bioreactors, which enables spatiotemporal control of flow fields in real time. Our adaptive approach offers the flexibility of dialing-in arbitrary shear stress distributions and adjusting flow field patterns in a scaffold over time in response to cell growth without needing to alter scaffold structure. This is achieved with a multi-inlet bioreactor and a control algorithm with learning capabilities to dynamically solve the inverse problem of computing the inlet pressure distribution required over the multiple inlets to obtain a target flow field. The new method constitutes a new platform for studies of cellular responses to mechanical forces in complex environments and opens potentially transformative possibilities for TE.


Asunto(s)
Técnicas de Cultivo Celular por Lotes/instrumentación , Reactores Biológicos , Microfluídica/instrumentación , Ingeniería de Tejidos/instrumentación , Andamios del Tejido , Técnicas de Cultivo Celular por Lotes/métodos , Proliferación Celular/fisiología , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Mecanotransducción Celular/fisiología , Microfluídica/métodos , Porosidad , Resistencia al Corte/fisiología , Estrés Mecánico , Ingeniería de Tejidos/métodos
10.
IEEE Trans Med Imaging ; 34(9): 1822-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25769149

RESUMEN

Conventional image restoration algorithms use transform-domain filters, which separate the noise from the sparse signal among the transform components or apply spatial smoothing filters in real space whose design relies on prior assumptions about the noise statistics. These filters also reduce the information content of the image by suppressing spatial frequencies or by recognizing only a limited set of shapes. Here we show that denoising can be efficiently done using a nonlinear filter, which operates along patch neighborhoods and multiple copies of the original image. The use of patches enables the algorithm to account for spatial correlations in the random field whereas the multiple copies are used to recognize the noise statistics. The nonlinear filter, which is implemented by a hierarchical multistage system of multilayer perceptrons, outperforms state-of-the-art denoising algorithms such as those based on collaborative filtering and total variation. Compared to conventional denoising algorithms, our filter can restore images without blurring them, making it attractive for use in medical imaging where the preservation of anatomical details is critical.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación , Cabeza/anatomía & histología , Humanos , Fantasmas de Imagen , Relación Señal-Ruido
11.
Biomaterials ; 34(8): 1980-6, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23245922

RESUMEN

Mechanical forces such as fluid shear have been shown to enhance cell growth and differentiation, but knowledge of their mechanistic effect on cells is limited because the local flow patterns and associated metrics are not precisely known. Here we present real-time, non-invasive measures of local hydrodynamics in 3D biomaterials based on nuclear magnetic resonance. Microflow maps were further used to derive pressure, shear and fluid permeability fields. Finally, remodeling of collagen gels in response to precise fluid flow parameters was correlated with structural changes. It is anticipated that accurate flow maps within 3D matrices will be a critical step towards understanding cell behavior in response to controlled flow dynamics.


Asunto(s)
Materiales Biocompatibles/química , Sistemas de Computación , Reología , Biopolímeros/química , Líquido Extracelular/fisiología , Hidrodinámica , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Espectroscopía de Resonancia Magnética , Poliésteres/química , Porosidad , Andamios del Tejido/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA