Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 20(1): 284-292, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30421496

RESUMEN

PURPOSE: To compare single-shot echo-planar (SS-EPI)-based and turbo spin-echo (SS-TSE)-based diffusion-weighted imaging (DWI) in Non-Small Cell Lung Cancer (NSCLC) patients and to characterize the distributions of apparent diffusion coefficient (ADC) values generated by the two techniques. METHODS: Ten NSCLC patients were enrolled in a prospective IRB-approved study to compare and optimize DWI using EPI and TSE-based techniques for radiotherapy planning. The imaging protocol included axial T2w, EPI-based DWI and TSE-based DWI on a 3 T Philips scanner. Both EPI-based and TSE-based DWI sequences used three b values (0, 400, and 800 s/mm2 ). The acquisition times for EPI-based and TSE-based DWI were 5 and 8 min, respectively. DW-MR images were manually coregistered with axial T2w images, and tumor volume contoured on T2w images were mapped onto the DWI scans. A pixel-by-pixel fit of tumor ADC was calculated based on monoexponential signal behavior. Tumor ADC mean, standard deviation, kurtosis, and skewness were calculated and compared between EPI and TSE-based DWI. Image distortion and ADC values between the two techniques were also quantified using fieldmap analysis and a NIST traceable ice-water diffusion phantom, respectively. RESULTS: The mean ADC for EPI and TSE-based DWI were 1.282 ± 0.42 × 10-3 and 1.211 ± 0.31 × 10-3  mm2 /s. The average skewness and kurtosis were 0.14 ± 0.4 and 2.43 ± 0.40 for DWI-EPI and -0.06 ± 0.69 and 2.89 ± 0.62 for DWI-TSE. Fieldmap analysis showed a mean distortion of 13.72 ± 8.12 mm for GTV for DWI-EPI and 0.61 ± 0.4 mm for DWI-TSE. ADC values obtained using the diffusion phantom for the two techniques were within 0.03 × 10-3  mm2 /s with respect to each other as well as the established values. CONCLUSIONS: Diffusion-weighted turbo spin-echo shows better geometrical accuracy compared to DWI-EPI. Mean ADC values were similar with both acquisitions but the shape of the histograms was different based on the skewness and kurtosis values. The impact of differences in respiratory technique on ADC values requires further investigation.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Adenocarcinoma/radioterapia , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/radioterapia , Femenino , Humanos , Imagenología Tridimensional , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/radioterapia , Masculino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Carga Tumoral
2.
Eur Radiol ; 27(4): 1605-1612, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27436029

RESUMEN

OBJECTIVES: To examine whether post-chemoradiotherapy (CRT) DCE-MRI can identify rectal cancer patients with pathologic complete response (pCR). METHODS: From a rectal cancer surgery database 2007-2014, 61 consecutive patients that met the following inclusion criteria were selected for analysis: (1) stage II/III primary rectal adenocarcinoma; (2) received CRT; (3) underwent surgery (4); underwent rectal DCE-MRI on a 1.5-T MRI scanner. Two experienced radiologists, in consensus, drew regions of interest (ROI) on the sagittal DCE-MRI image in the tumour bed. These were exported from ImageJ to in-house Matlab code for modelling using the Tofts model. K trans, K ep and v e values were compared to pathological response. RESULTS: Of the 61 initial patients, 37 had data considered adequate for fitting to obtain perfusion parameters. Among the 13 men and 24 women, median age 53 years, there were 8 pCR (22 %). K trans could not distinguish patients with pCR. For patients with 90 % or greater response, mean K trans and K ep values were statistically significant (p = 0.032 and 0.027, respectively). Using a cutoff value of K trans = 0.25 min-1, the AUC was 0.71. CONCLUSION: K trans could be used to identify patients with 90 % or more response to chemoradiotherapy for rectal cancer with an AUC of 0.7. KEY POINTS: • Chemoradiotherapy for rectal cancer causes decreased blood flow and permeability in the tumour bed. • Lower values of blood flow and permeability correlate with good tumour response. • K trans of 0.25min -1 best identifies patients with ≥90 % response with AUC 0.71.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/terapia , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/terapia , Adenocarcinoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Quimioradioterapia/métodos , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Terapia Neoadyuvante/métodos , Estadificación de Neoplasias , Perfusión , Pronóstico , Neoplasias del Recto/patología , Estudios Retrospectivos , Resultado del Tratamiento
3.
J Magn Reson Imaging ; 40(6): 1414-21, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24243554

RESUMEN

PURPOSE: To assess whether an artificial neural network (ANN) model is a useful tool for automatic detection of cancerous voxels in the prostate from (1)H-MRSI datasets and whether the addition of information about anatomical segmentation improves the detection of cancer. MATERIALS AND METHODS: The Institutional Review Board approved this HIPAA-compliant study and waived informed consent. Eighteen men with prostate cancer (median age, 55 years; range, 36-71 years) who underwent endorectal MRI/MRSI before radical prostatectomy were included in this study. These patients had at least one cancer area on whole-mount histopathological map and at least one matching MRSI voxel suspicious for cancer detected. Two ANN models for automatic classification of MRSI voxels in the prostate were implemented and compared: model 1, which used only spectra as input, and model 2, which used the spectra plus information from anatomical segmentation. The models were trained, tested and validated using spectra from voxels that the spectroscopist had designated as cancer and that were verified on histopathological maps. RESULTS: At ROC analysis, model 2 (AUC = 0.968) provided significantly better (P = 0.03) classification of cancerous voxels than did model 1 (AUC = 0.949). CONCLUSION: Automatic analysis of prostate MRSI to detect cancer using ANN model is feasible. Application of anatomical segmentation from MRI as an additional input to ANN improves the accuracy of detecting cancerous voxels from MRSI.


Asunto(s)
Biomarcadores de Tumor/análisis , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación , Reconocimiento de Normas Patrones Automatizadas/métodos , Neoplasias de la Próstata/química , Neoplasias de la Próstata/diagnóstico , Espectroscopía de Protones por Resonancia Magnética/métodos , Adulto , Anciano , Algoritmos , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
NMR Biomed ; 26(2): 204-12, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22961714

RESUMEN

Hepatic steatosis is a hallmark of chemotherapy-induced liver injury. We made serial (1) H MRS measurements of hepatic lipids in patients over the time course of a 24-week chemotherapeutic regimen to determine whether (1) H MRS could be used to monitor the progression of chemotherapy-induced steatosis. Thirty-four patients with stage III or IV colorectal cancer receiving 5-fluorouracil, folinic acid and oxaliplatin (n=21) or hepatic arterial infusion of floxuridine with systemic irinotecan (n=13) were studied prospectively. (1) H MRS studies were performed at baseline and after 6 and 24 weeks of treatment. A (1) H MR spectrum was acquired from the liver during a breath hold and the ratio of fat to fat+water (FFW) was calculated to give a measure of hepatic triglycerides (HTGCs). The methodology was histologically validated in 18 patients and the reproducibility was assessed in 16 normal volunteers. Twenty-seven patients completed baseline, 6-week and 24-week (1) H MRS examinations and one was censored. Thirteen of 26 patients (50%) showed an increase in FFW after completion of treatment. Six patients (23%) developed hepatic steatosis and two patients converted from steatosis to nonsteatotic liver. Patients whose 6-week hepatic lipid levels had increased significantly relative to baseline also had a high probability of lipid elevation relative to baseline at the completion of treatment. Serial (1) H MRS is effective for the monitoring of HTGC changes during chemotherapy and for the detection of chemotherapy-associated steatosis. Six of 26 patients developed steatosis during chemotherapy. Lipid changes were observable at 6 weeks.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias Colorrectales/tratamiento farmacológico , Neoplasias Colorrectales/metabolismo , Hígado Graso/inducido químicamente , Hígado Graso/metabolismo , Metabolismo de los Lípidos/efectos de los fármacos , Adulto , Anciano , Neoplasias Colorrectales/complicaciones , Femenino , Humanos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Protones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
5.
Radiology ; 265(2): 478-87, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22952382

RESUMEN

PURPOSE: To prospectively evaluate diagnostic performance of T2-weighted magnetic resonance (MR) imaging and MR spectroscopic imaging in detecting lesions stratified by pathologic volume and Gleason score in men with clinically determined low-risk prostate cancer. MATERIALS AND METHODS: The institutional review board approved this prospective, HIPAA-compliant study. Written informed consent was obtained from 183 men with clinically low-risk prostate cancer (cT1-cT2a, Gleason score≤6 at biopsy, prostate-specific antigen [PSA] level<10 ng/mL [10 µg/L]) undergoing MR imaging before prostatectomy. By using a scale of 1-5 (score 1, definitely no tumor; score 5, definitely tumor), two radiologists independently scored likelihood of tumor per sextant on T2-weighted images. Two spectroscopists jointly recorded locations of lesions with metabolic features consistent with tumor on MR spectroscopic images. Whole-mount step-section histopathologic analysis constituted the reference standard. Diagnostic performance at sextant level (T2-weighted imaging) and detection sensitivities (T2-weighted imaging and MR spectroscopic imaging) for lesions of 0.5 cm3 or larger were calculated. RESULTS: For T2-weighted imaging, areas under the receiver operating characteristic curves for sextant-level detection were 0.77 (reader 1) and 0.82 (reader 2). For lesions of ≥0.5 cm3 and, 1

Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Neoplasias de la Próstata/patología , Adulto , Anciano , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad
6.
BJU Int ; 109(9): 1315-22, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21933336

RESUMEN

UNLABELLED: Study Type--Prognosis (case series). Level of Evidence 4. What's known on the subject? And what does the study add? Nomograms are available that combine clinical and biopsy findings to predict the probability of pathologically insignificant prostate cancer in patients with clinically low-risk disease. Based on data from patients with Gleason score 6, clinical stage ≤ T2a and PSA <20 ng/ml, our group developed the first nomogram models for predicting insignificant prostate cancer that incorporated clinical data, detailed biopsy data and findings from MRI or MRI/MRSI (BJU Int. 2007;99(4):786-93). When tested retrospectively, these MR models performed significantly better than standard clinical models with and without detailed biopsy data. We prospectively validated the previously published MR-based nomogram models in a population of patients with Gleason score 6, clinical stage ≤ T2a and PSA <10 ng/ml. Based on data from this same population, we also developed two new models for predicting insignificant prostate cancer that combine MR findings and clinical data without detailed biopsy data. Upon initial testing, the new MR models performed significantly better than a clinical model lacking detailed biopsy data. OBJECTIVES: • To validate previously published nomograms for predicting insignificant prostate cancer (PCa) that incorporate clinical data, percentage of biopsy cores positive (%BC+) and magnetic resonance imaging (MRI) or MRI/MR spectroscopic imaging (MRSI) results. • We also designed new nomogram models incorporating magnetic resonance results and clinical data without detailed biopsy data. Nomograms for predicting insignificant PCa can help physicians counsel patients with clinically low-risk disease who are choosing between active surveillance and definitive therapy. PATIENTS AND METHODS: • In total, 181 low-risk PCa patients (clinical stage T1c-T2a, prostate-specific antigen level <10 ng/mL, biopsy Gleason score of 6) had MRI/MRSI before surgery. • For MRI and MRI/MRSI, the probability of insignificant PCa was recorded prospectively and independently by two radiologists on a scale from 0 (definitely insignificant) to 3 (definitely significant PCa). • Insignificant PCa was defined on surgical pathology. • There were four models incorporating MRI or MRI/MRSI and clinical data with and without %BC+ that were compared with a base clinical model without %BC and a more comprehensive clinical model with %BC+. Prediction accuracy was assessed using areas under receiver-operator characteristic curves. RESULTS: • At pathology, 27% of patients had insignificant PCa, and the Gleason score was upgraded in 56.4% of patients. • For both readers, all magnetic resonance models performed significantly better than the base clinical model (P ≤ 0.05 for all) and similarly to the more comprehensive clinical model. CONCLUSIONS: • Existing models incorporating magnetic resonance data, clinical data and %BC+ for predicting the probability of insignificant PCa were validated. • All MR-inclusive models performed significantly better than the base clinical model.


Asunto(s)
Nomogramas , Neoplasias de la Próstata/diagnóstico , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad
7.
Adv Radiat Oncol ; 7(1): 100799, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34765805

RESUMEN

PURPOSE: To assess the effect of a combination of compressed sensing and SENSitivity Encoding (SENSE) acceleration techniques on radiation therapy magnetic resonance imaging (MRI) simulation workflows. METHODS AND MATERIALS: Thirty-seven acquisitions were performed with both SENSE-only (SENSE) and combined compressed sensing and SENSE (CS) techniques in 24 patients receiving radiation therapy MRI simulation for a wide range of disease sites. The anatomic field of view prescription and image resolution were identical for both SENSE and CS acquisitions to ensure fair comparison. The acquisition time of all images was recorded to assess time savings. For each image pair, image quality, and ability to contour were assessed by 2 radiation oncologists. Aside from direct image pair comparisons, the feasibility of using CS to improve MRI simulation protocols by increasing image resolution, field of view, and reducing motion artifacts was also evaluated. RESULTS: CS resulted in an average reduction of 27% in scan time with negligible changes in image quality and the ability to contour structures for RT treatment planning compared with SENSE. Physician scoring of image quality and ability to contour shows that while SENSE still has slightly better image quality compared with CS, this observed difference in image quality did not affect the ability to contour. In addition, the higher acceleration capability of CS enabled use of superior-inferior direction phase encoding in a sagittal 3-dimensional T2-weighted scan for substantially improved visibility of the prostatic urethra, which eliminated the need for a Foley catheter in most patients. CONCLUSIONS: The combination of compressed sensing and parallel imaging resulted in marked improvements in the MRI Simulation workflow. The scan time was reduced without significantly affecting image quality in the context of ability to contour. The acceleration capabilities allowed for increased image resolution under similar scanning times as well as significantly improved urethra visualization in prostate simulations.

8.
NMR Biomed ; 24(9): 1159-68, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21994185

RESUMEN

The topoisomerase I inhibitor, irinotecan, and its active metabolite SN-38 have been shown to induce G(2) /M cell cycle arrest without significant cell death in human colon carcinoma cells (HCT-116). Subsequent treatment of these G(2) /M-arrested cells with the cyclin-dependent kinase inhibitor, flavopiridol, induced these cells to undergo apoptosis. The goal of this study was to develop a noninvasive metabolic biomarker for early tumor response and target inhibition of irinotecan followed by flavopiridol treatment in a longitudinal study. A total of eleven mice bearing HCT-116 xenografts were separated into two cohorts where one cohort was administered saline and the other treated with a sequential course of irinotecan followed by flavopiridol. Each mouse xenograft was longitudinally monitored with proton ((1) H)-decoupled phosphorus ((31) P) magnetic resonance spectroscopy (MRS) before and after treatment. A statistically significant decrease in phosphocholine (p = 0.0004) and inorganic phosphate (p = 0.0103) levels were observed in HCT-116 xenografts following treatment, which were evidenced within twenty-four hours of treatment completion. Also, a significant growth delay was found in treated xenografts. To discern the underlying mechanism for the treatment response of the xenografts, in vitro HCT-116 cell cultures were investigated with enzymatic assays, cell cycle analysis, and apoptotic assays. Flavopiridol had a direct effect on choline kinase as measured by a 67% reduction in the phosphorylation of choline to phosphocholine. Cells treated with SN-38 alone underwent 83 ± 5% G(2) /M cell cycle arrest compared to untreated cells. In cells, flavopiridol alone induced 5 ± 1% apoptosis while the sequential treatment (SN-38 then flavopiridol) resulted in 39 ± 10% apoptosis. In vivo (1) H-decoupled (31) P MRS indirectly measures choline kinase activity. The decrease in phosphocholine may be a potential indicator of early tumor response to the sequential treatment of irinotecan followed by flavopiridol in noninvasive and/or longitudinal studies.


Asunto(s)
Neoplasias Colorrectales/tratamiento farmacológico , Espectroscopía de Resonancia Magnética/métodos , Protones , Ensayos Antitumor por Modelo de Xenoinjerto , Animales , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Protocolos de Quimioterapia Combinada Antineoplásica/farmacología , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Apoptosis/efectos de los fármacos , Camptotecina/análogos & derivados , Camptotecina/farmacología , Camptotecina/uso terapéutico , Ciclo Celular/efectos de los fármacos , Colina Quinasa/aislamiento & purificación , Colina Quinasa/metabolismo , Citidililtransferasa de Colina-Fosfato/metabolismo , Femenino , Flavonoides/farmacología , Flavonoides/uso terapéutico , Células HCT116 , Humanos , Irinotecán , Ratones , Isótopos de Fósforo , Piperidinas/farmacología , Piperidinas/uso terapéutico , Saccharomyces cerevisiae/efectos de los fármacos , Saccharomyces cerevisiae/enzimología , Resultado del Tratamiento
9.
J Magn Reson Imaging ; 34(2): 336-44, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21780228

RESUMEN

PURPOSE: First, to evaluate hepatocyte phospholipid metabolism and energetics during liver regeneration stimulated by portal vein embolization (PVE) using proton-decoupled (31)P MR spectroscopic imaging ((31)P-MRSI). Second, to compare the biophysiologic differences between hepatic regeneration stimulated by PVE and by partial hepatectomy (PH). MATERIALS AND METHODS: Subjects included six patients with hepatic metastases from colorectal cancer who were scheduled to undergo right PVE before definitive resection of right-sided tumor. (31)P-MRSI was performed on the left liver lobe before PVE and 48 h following PVE. Normalized quantities of phosphorus-containing hepatic metabolites were analyzed from both visits. In addition, MRSI data at 48 h following partial hepatectomy were compared with the data from the PVE patients. RESULTS: At 48 h after PVE, the ratio of phosphomonoesters to phosphodiesters in the nonembolized lobe was significantly elevated. No significant changes were found in nucleoside triphosphates (NTP) and Pi values. The phosphomonoester (PME) to phosphodiester (PDE) ratio in regenerating liver 48 h after partial hepatectomy was significantly greater than PME/PDE 48 h after PVE. CONCLUSION: (31)P-MRSI is a valid technique to noninvasively evaluate cell membrane metabolism following PVE. The different degree of biochemical change between partial hepatectomy and PVE indicates that hepatic growth following these two procedures does not follow the same course.


Asunto(s)
Embolización Terapéutica/métodos , Hepatocitos/patología , Hígado/patología , Espectroscopía de Resonancia Magnética/métodos , Isótopos de Fósforo/farmacología , Vena Porta/patología , Adulto , Anciano , Anciano de 80 o más Años , Membrana Celular/metabolismo , Femenino , Hepatectomía/métodos , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Protones , Espectrofotometría/métodos , Factores de Tiempo
10.
J Urol ; 184(6): 2320-7, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20952035

RESUMEN

PURPOSE: Radical prostatectomy has significant side effects. Preoperative information predicting its long-term outcome would be valuable to patients and physicians. We determined whether pretreatment endorectal magnetic resonance imaging/magnetic resonance spectroscopic imaging predicts biochemical recurrence after radical prostatectomy. MATERIALS AND METHODS: Of 202 patients who underwent endorectal magnetic resonance imaging/magnetic resonance spectroscopic imaging from January 2000 to December 2002 before radical prostatectomy 130 satisfied study inclusion criteria and were included in analysis. We compared imaging factors with potential predictive capability to biochemical recurrence data, including magnetic resonance imaging risk score based on local disease extent and magnetic resonance spectroscopic imaging index lesion characteristics, such as the number of voxels and degree of metabolic abnormality (magnetic resonance spectroscopic imaging grade). We evaluated associations of these imaging variables with time to biochemical recurrence by Cox proportional hazards regression adjusted for known predictors of biochemical recurrence, such as stage, grade and prostate specific antigen. RESULTS: At a median 68-month followup there were 26 biochemical failures. Risk score, lesion volume and high grade voxels each correlated with time to biochemical recurrence. In a model combining clinical parameters risk score, lesion volume and at least 1 high grade voxel the magnetic resonance spectroscopic imaging variables remained significant but the magnetic resonance imaging score dropped out. CONCLUSIONS: Index lesion volume on magnetic resonance spectroscopic imaging and high grade magnetic resonance spectroscopic imaging voxels correlate with time to biochemical recurrence after radical prostatectomy even when adjusted for clinical data. Results suggest the preoperative predictive usefulness of endorectal magnetic resonance imaging/magnetic resonance spectroscopic imaging in patients considering radical prostatectomy.


Asunto(s)
Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Prostatectomía , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/cirugía , Biomarcadores , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/sangre , Valor Predictivo de las Pruebas , Cuidados Preoperatorios , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/sangre , Recto
11.
Clin Cancer Res ; 15(11): 3842-9, 2009 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-19435838

RESUMEN

PURPOSE: To evaluate whether pretreatment magnetic resonance imaging (MRI)/MR spectroscopic imaging (MRSI) findings and molecular markers in surgical specimens correlate with each other and with pretreatment clinical variables (biopsy Gleason score, clinical stage, and prostate-specific antigen level) and whether they contribute incremental value in predicting prostate cancer recurrence. EXPERIMENTAL DESIGN: Eighty-eight prostate cancer patients underwent MRI/MRSI before radical prostatectomy; imaging findings were scored on a scale of 1 to 7 (no tumor seen-lymph node metastasis). Ki-67, phospho-Akt, and androgen receptor expression in surgical specimens were assessed by immunohistochemistry. To examine correlations between markers and imaging scores, Spearman's correlation was used. To test whether markers and imaging scores differed by clinical stage or Gleason score, Wilcoxon's rank sum test was used. To examine time to recurrence, the methods of Kaplan-Meier were used. Cox proportional hazards models were built and their concordance indices (C-indices) were calculated to evaluate prediction of recurrence. RESULTS: All markers correlated moderately strongly with MRI/MRSI score (all correlation coefficients >0.5). Markers and MRI/MRSI score were strongly associated with clinical stage and biopsy Gleason score (P < 0.01 for all). At last follow-up, 27 patients had recurrence. C-indices for MRI/MRSI score and all markers were associated with time to recurrence and ranged from 0.78 to 0.89. A Cox model combining all clinical predictors had a C-index of 0.89; the C-index increased to 0.95 when MRI/MRSI score was added and to 0.97 when markers were also added. CONCLUSIONS: MRI/MRSI findings and molecular markers correlated well with each other and contributed incremental value to clinical variables in predicting prostate cancer recurrence.


Asunto(s)
Biomarcadores de Tumor/análisis , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/patología , Anciano , Humanos , Inmunohistoquímica/estadística & datos numéricos , Estimación de Kaplan-Meier , Antígeno Ki-67/análisis , Imagen por Resonancia Magnética/estadística & datos numéricos , Espectroscopía de Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Fosfoproteínas/análisis , Valor Predictivo de las Pruebas , Pronóstico , Modelos de Riesgos Proporcionales , Neoplasias de la Próstata/metabolismo , Proteínas Proto-Oncogénicas c-akt/análisis , Receptores Androgénicos/análisis , Índice de Severidad de la Enfermedad
12.
Med Phys ; 47(7): 3091-3102, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32166757

RESUMEN

PURPOSE: The purpose of this study was to develop T2-weighted (T2w) time-resolved (TR) four-dimensional magnetic resonance imaging (4DMRI) reconstruction technique with higher soft-tissue contrast for multiple breathing cycle motion assessment by building a super-resolution (SR) framework using the T1w TR-4DMRI reconstruction as guidance. METHODS: The multi-breath T1w TR-4DMRI was reconstructed by deforming a high-resolution (HR: 2 × 2 × 2 mm3 ) volumetric breath-hold (BH, 20s) three-dimensional magnetic resonance imaging (3DMRI) image to a series of low-resolution (LR: 5 × 5 × 5 mm3 ) 3D cine images at a 2Hz frame rate in free-breathing (FB, 40 s) using an enhanced Demons algorithm, namely [T1BH →FB] reconstruction. Within the same imaging session, respiratory-correlated (RC) T2w 4DMRI (2 × 2 × 2 mm3 ) was acquired based on an internal navigator to gain HR T2w (T2HR ) in three states (full exhalation and mid and full inhalation) in ~5 min. Minor binning artifacts in the RC-4DMRI were automatically identified based on voxel intensity correlation (VIC) between consecutive slices as outliers (VIC < VICmean -σ) and corrected by deforming the artifact slices to interpolated slices from the adjacent slices iteratively until no outliers were identified. A T2HR image with minimal deformation (<1 cm at the diaphragm) from the T1BH image was selected for multi-modal B-Spline deformable image registration (DIR) to establish the T2HR -T1BH voxel correspondence. Two approaches to reconstruct T2w TR-4DMRI were investigated: (A) T2HR →[T1BH →FB]: to deform T2w HR to T1w BH only as T1w TR-4DMRI was reconstructed, and combine the two displacement vector fields (DVFs) to reconstruct T2w TR-4DMRI, and (B) [T2HR ←T1BH ]→FB: to deform T1w BH to T2w HR first and apply the deformed T1w BH to reconstruct T2w TR-4DMRI. The reconstruction times were similar, 8-12 min per volume. To validate the two methods, T2w- and T1w-mapped 4D XCAT digital phantoms were utilized with three synthetic spherical tumors (ϕ = 2.0, 3.0, and 4.0 cm) in the lower or mid lobes as the ground truth to evaluate the tumor location (the center of mass, COM), size (volume ratio, %V), and shape (Dice index). Six lung cancer patients were scanned under an IRB-approved protocol and the T2w TR-4DMRI images reconstructed from the two methods were compared based on the preservation of the three tumor characteristics. The local tumor-contained image quality was also characterized using the VIC and structure similarity (SSIM) indexes. RESULTS: In the 4D digital phantom, excellent tumor alignment after T2HR -T1HR DIR is achieved: ∆COM = 0.8 ± 0.5 mm, %V = 1.06 ± 0.02, and Dice = 0.91 ± 0.03, in both deformation directions using the DIR-target image as the reference. In patients, binning artifacts are corrected with improved image quality: average VIC increases from 0.92 ± 0.03 to 0.95 ± 0.01. Both T2w TR-4DMRI reconstruction methods produce similar tumor alignment errors ∆COM = 2.9 ± 0.6 mm. However, method B ([T2HR ←T1BH ]→FB) produces superior results in preserving more T2w tumor features with a higher %V = 0.99 ± 0.03, Dice = 0.81 ± 0.06, VIC = 0.85 ± 0.06, and SSIM = 0.65 ± 0.10 in the T2w TR-4DMRI images. CONCLUSIONS: This study has demonstrated the feasibility of T2w TR-4DMRI reconstruction with high soft-tissue contrast and adequately-preserved tumor position, size, and shape in multiple breathing cycles. The T2w-centric DIR (method B) produces a superior solution for the SR-based framework of T2w TR-4DMRI reconstruction with highly preserved tumor characteristics and local image features, which are useful for tumor delineation and motion management in radiation therapy.


Asunto(s)
Artefactos , Respiración , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Fantasmas de Imagen
13.
Phys Imaging Radiat Oncol ; 16: 43-49, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33134566

RESUMEN

BACKGROUND AND PURPOSE: Magnetic Resonance (MR)-only planning has been implemented clinically for radiotherapy of prostate cancer. However, fewer studies exist regarding the overall success rate of MR-only workflows. We report on successes and challenges of implementing MR-only workflows for prostate. MATERIALS AND METHODS: A total of 585 patients with prostate cancer underwent an MR-only simulation and planning between 06/2016-06/2018. MR simulation included images for contouring, synthetic-CT generation and fiducial identification. Workflow interruptions occurred that required a backup CT, a re-simulation or an update to our current quality assurance (QA) process. The challenges were prospectively evaluated and classified into syn-CT generation, motion/artifacts in the MRs, fiducial QA and bowel preparation guidelines. RESULTS: MR-only simulation was successful in 544 (93.2 %) patients. . In seventeen patients (2.9%), reconstruction of synthetic-CT failed due to patient size, femur angulation, or failure to determine the body contour. Twenty-four patients (4.1%) underwent a repeat/backup CT scan because of artifacts on the MR such as image blur due to patient motion or biopsy/surgical artifacts that hampered identification of the implanted fiducial markers. In patients requiring large coverage due to nodal involvement, inhomogeneity artifacts were resolved by using a two-stack acquisition and adaptive inhomogeneity correction. Bowel preparation guidelines were modified to address frequent rectum/gas issues due to longer MR scan time. CONCLUSIONS: MR-only simulation has been successfully implemented for a majority of patients in the clinic. However, MR-CT or CT-only pathway may still be needed for patients where MR-only solution fails or patients with MR contraindications.

14.
Med Phys ; 47(7): 3143-3152, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32304237

RESUMEN

PURPOSE: To assess the performance and optimize the MR image quality when using a custom-built flexible radiofrequency (RF) spine coil array fitted between the immobilization device and the patient for spine radiotherapy treatment planning. METHODS: A 32 channel flexible custom-designed receive-only coil array has been developed for spine radiotherapy simulation for a 3 T Philips MR scanner. Coil signal-to-noise performance and interactions with standard vendor hardware were assessed. In four volunteers, immobilization molds were created with a dummy version of the array within the mold, and subjects were scanned using the custom array in the mold. Phantoms and normal volunteers were scanned with both the custom spine coil array and the vendor's FDA-approved in-table posterior coil array to compare performance. RESULTS: The superior-inferior field of view for the custom spine array was ~30 cm encompassing at least 10 vertebrae. A noise correlation matrix showed at least 25 dB isolation between all coil elements. Signal-to-noise ratio (SNR) calculated on a phantom scan at the depth of the spinal cord was a factor of 3 higher with the form-fit spine array as compared to the vendor's posterior coil array. The body coil B1 transmit map was equivalent with and without the spine array in place demonstrating that the elements are decoupled from the body coil. Volunteer imaging showed improved SNR as compared to the vendor's posterior coil array. The custom array permitted a high degree of acceleration making possible the acquisition of isotropic high-resolution 1.1 × 1.1 × 1.1 mm3 three-dimensional data set over a 30-cm section of the spine in less than 5 min. CONCLUSION: The custom-designed form-fitting flexible spine coil array provided enhanced SNR and increased acceleration compared to the vendor's posterior array. Future studies will assess MR-based spinal cord imaging with the custom coil in comparison to CT myelogram.


Asunto(s)
Imagen por Resonancia Magnética , Columna Vertebral , Diseño de Equipo , Humanos , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido , Columna Vertebral/diagnóstico por imagen
15.
Radiology ; 250(3): 803-12, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19244047

RESUMEN

PURPOSE: To retrospectively assess whether magnetic resonance (MR) imaging and MR spectroscopic imaging and selected molecular markers correlate with each other and with clinically insignificant and significant prostate cancer (PCa), as defined at surgical pathologic analysis. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant study and waived informed consent. Eighty-nine men (mean age, 63 years; range, 46-79 years) with biopsy-proved PCa underwent combined endorectal MR imaging and MR spectroscopic imaging before radical prostatectomy. Suspicion of clinically insignificant PCa was retrospectively and separately recorded for MR imaging and combined MR imaging and MR spectroscopic imaging by using a scale of 0-3. Clinically insignificant PCa was pathologically defined as organ-confined cancer of 0.5 cm(3) or less without poorly differentiated elements. Prostatectomy specimens underwent immunohistochemical analysis for three molecular markers: Ki-67, phospho-Akt (pAkt), and androgen receptor (AR). To examine differences in marker levels for clinically insignificant and significant cancer, a Wilcoxon rank sum test was used. To examine correlations between marker levels and MR imaging or combined MR imaging and MR spectroscopic imaging scores, the Spearman correlation was used. RESULTS: Twenty-one (24%) patients had clinically insignificant and 68 (76%) had clinically significant PCa at surgical pathologic review. All markers were significantly correlated with MR imaging and combined MR imaging and MR spectroscopic imaging findings (all correlation coefficients >0.5). In differentiating clinically insignificant from clinically significant PCa, areas under the receiver operating characteristic curves for Ki-67, AR, pAkt, MR imaging, and combined MR imaging and MR spectroscopic imaging were 0.75, 0.78, 0.80, 0.85, and 0.91, respectively. CONCLUSION: The use of pretreatment MR imaging or combined MR imaging and MR spectroscopic imaging and molecular marker analyses of biopsy samples could facilitate better treatment selection. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/250/3/803/DC1.


Asunto(s)
Antígeno Ki-67/análisis , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/patología , Proteínas Proto-Oncogénicas c-akt/análisis , Receptores Androgénicos/análisis , Anciano , Biomarcadores/análisis , Humanos , Masculino , Persona de Mediana Edad , Neoplasias de la Próstata/metabolismo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Distribución Tisular
16.
Radiology ; 252(2): 449-57, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19703883

RESUMEN

PURPOSE: To retrospectively determine the accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging for identifying cancer in the prostate peripheral zone (PZ) and to assess the accuracy of tumor volume measurements made with T2-weighted imaging and combined T2-weighted and DW MR imaging by using surgical pathologic examination as the reference standard. MATERIALS AND METHODS: The institutional review board issued a waiver of informed consent for this HIPAA-compliant study. Forty-two patients underwent endorectal MR at 1.5 T before undergoing radical prostatectomy for prostate cancer and had at least one PZ tumor larger than 0.1 cm(3) at surgical pathologic examination. On T2-weighted images, an experienced radiologist outlined suspected PZ tumors. Two apparent diffusion coefficient (ADC) cutoff values were identified by using the Youden index and published literature. Image cluster analysis was performed on voxels within the suspected tumor regions. Associations between volume measurements from imaging and from pathologic examination were assessed by using concordance correlation coefficients (CCCs). The sensitivity and specificity of ADCs for identifying malignant PZ voxels were calculated. RESULTS: In identifying malignant voxels, respective ADC cutoff values of 0.0014 and 0.0016 mm(2)/sec yielded sensitivity of 82% and 95% and specificity of 85% and 65%, respectively. Sixty PZ cancer lesions larger than 0.1 cm(3) were found at pathologic examination; 43 were detected by the radiologist. CCCs between imaging and pathologic tumor volume measurements were 0.36 for T2-weighted imaging, and 0.46 and 0.60 for combined T2-weighted and DW MR imaging with ADC cutoffs of 0.0014 and 0.0016 mm(2)/sec, respectively; the CCC of combined T2-weighted and DW MR imaging (ADC cutoff, 0.0016 mm(2)/sec) was significantly higher (P = .006) than that of T2-weighted imaging alone. CONCLUSION: Adding DW MR to T2-weighted imaging can significantly improve the accuracy of prostate PZ tumor volume measurement. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/252/2/449/DC1.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Neoplasias de la Próstata/patología , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto
17.
Pract Radiat Oncol ; 9(6): e534-e540, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31252087

RESUMEN

PURPOSE: The use of magnetic resonance imaging (MRI) for radiation therapy simulation is growing because of its ability to provide excellent delineation of target tissue and organs at risk. With the use of hypofractionated schemes in prostate cancer, urethral sparing is essential; however, visualization of the prostatic urethra can be challenging because of the presence of benign prostatic hyperplasia as well as respiratory motion artifacts. The goal of this study was to compare the utility of 2 motion-insensitive, T2-weighted MRI pulse sequences for urethra visualization in the setting of MRI-based simulation. METHODS AND MATERIALS: Twenty-two patients undergoing MRI simulation without Foley catheters were imaged on a 3 Tesla MRI scanner between October 2018 and January 2019. Sagittal multislice data were acquired using (1) MultiVane XD radial sampling with parallel imaging acceleration (MVXD) and (2) single-shot fast-spin-echo (SSFSE) sequences with acquisition times of 2 to 3 minutes per sequence. For each examination, 2 genitourinary radiologists scored prostatic urethra visibility on a 1-to-5 scale and rated the signal-to-noise ratio and the presence of artifacts in each series. RESULTS: Urethral visibility was scored higher in the MVXD series than in the SSFSE series in 18 of 22 cases (Reader 1) and 17 of 22 cases (Reader 2). The differences in scores between MVXD and SSFSE were statistically significant for both readers (P < .0001 for both, paired Student's t-test) and interobserver agreement was high (Cohen's kappa = 0.67). Both readers found the signal-to-noise ratio of the MVXD sequence to be superior in all cases. The MVXD sequence was found to generate more artifacts than the SSFSE sequence, but these tended to appear in the periphery and did not affect the ability to visualize the urethra. CONCLUSIONS: A radial T2-weighted multislice pulse sequence was superior to an SSFSE sequence for visualization of the urethra in the setting of magnetic resonance simulation for prostate cancer.


Asunto(s)
Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Uretra/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Neoplasias de la Próstata/patología
18.
Radiology ; 246(2): 480-8, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18227542

RESUMEN

PURPOSE: To retrospectively measure the mean apparent diffusion coefficient (ADC) with diffusion-weighted magnetic resonance (MR) imaging and the mean metabolic ratio (MET) with three-dimensional (3D) hydrogen 1 ((1)H) MR spectroscopic imaging in regions of interest (ROIs) drawn over benign and malignant peripheral zone (PZ) prostatic tissue and to assess ADC, MET, and combined ADC and MET for identifying malignant ROIs, with whole-mount histopathologic examination as the reference standard. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant retrospective study and issued a waiver of informed consent. From among 61 consecutive patients with prostate cancer, 38 men (median age, 61 years; range, 42-72 years) who underwent 1.5-T endorectal MR imaging before radical prostatectomy and who fulfilled all inclusion criteria of no prior hormonal or radiation treatment and at least one PZ lesion (volume, >0.1 cm(3)) at whole-mount pathologic examination were included. ADC maps were generated from diffusion-weighted MR imaging data, and MET maps of (choline plus polyamine plus creatine)/citrate were calculated from 3D (1)H MR spectroscopic imaging data. ROIs in the PZ identified by matching pathologic slides with T2-weighted images were overlaid on MET and ADC maps. Areas under the receiver operating characteristic curves (AUCs) were used to evaluate accuracy. RESULTS: The mean ADC +/- standard deviation, (1.39 +/- 0.23) x 10(-3) mm(2)/sec, and mean MET (0.92 +/- 0.32) for malignant ROIs differed significantly from the mean ADC, (1.69 +/- 0.24) x 10(-3) mm(2)/sec, and mean MET (0.73 +/- 0.18) for benign ROIs (P < .001 for both). In distinguishing malignant ROIs, combined ADC and MET (AUC = 0.85) performed significantly better than MET alone (AUC = 0.74; P = .005) and was also better than ADC alone (AUC = 0.81), although the difference was not statistically significant (P = .09). CONCLUSION: The combination of ADC and MET performs significantly better than MET for differentiating between benign and malignant ROIs in the PZ.


Asunto(s)
Biomarcadores de Tumor/análisis , Diagnóstico por Computador/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/metabolismo , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Protones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto
19.
Med Phys ; 44(7): 3706-3717, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28444772

RESUMEN

PURPOSE: The growing use of magnetic resonance imaging (MRI) as a substitute for computed tomography-based treatment planning requires the development of effective algorithms to generate electron density maps for treatment planning and patient setup verification. The purpose of this work was to develop a method to synthesize computerized tomography (CT) for MR-only radiotherapy of head and neck cancer patients. METHODS: The algorithm is based on registration of multiple patient datasets containing both MRI and CT images (a "multiatlas" algorithm). Twelve matched pairs of good quality CT and MRI scans (those without apparent motion and blurring artifacts) were selected from a pool of head and neck cancer patients to form the atlas. All atlas MRI scans were preprocessed to reduce scanner- and patient-induced intensity inhomogeneities and to standardize their intensity histograms. Atlas CT and MRIs were coregistered using a novel bone-to-air replacement technique applied to the CT scans that improves the similarity between CTs and MRIs and facilitates the registration process. For each new patient, all atlas MRIs are deformed initially onto the new patients' MRI. We introduce a generalized registration error (GRE) metric that automatically measures the goodness of local registration between MRI pairs. The final synthetic CT value at each point is a nonlinear GRE-weighted average of the atlas CTs. For evaluation, the leave-one-out technique was used for synthetic CT generation and the mean absolute error (MAE) between the original and synthetic CT was computed over the entire CT image. The impact of our proposed CT-MR registration scheme on the accuracy of the final synthetic CT was also studied. The original treatment plans were also recomputed on the new synthetic CTs and dose-volume histogram metrics were compared. In addition, the two-dimensional (2D) gamma analysis at 1%/1 mm and 2%/2 mm dose difference/distance to agreement was also performed to study the dose distribution at the isocenter. RESULTS: MAE error (± standard deviation) between the original and the synthetic CTs was 64 ± 10, 113 ± 12, and 130 ± 28 Hounsfield Unit (HU) for the entire image, air, and bone regions respectively. Our results showed that our proposed bone-suppression based CT-MR fusion and GRE-weighted strategy could lower the overall MAE error between the original and synthetic CTs by ~69% and ~34% respectively. Dose recalculation comparison showed highly consistent results between plans based on the synthetic vs. the original CTs. The 2D gamma analysis revealed the pass rate of 95.44 ± 2.5 and 99.36 ± 0.71 for 1%/1 mm and 2%/2 mm criteria respectively. Due to local registration weighting, the method is robust with respect to MRI imaging artifacts. CONCLUSION: We developed a novel image analysis technique to synthesize CT for head and neck anatomy. Novel methods were introduced to accurately register atlas CTs and MRIs as well as to weight the final electron density maps using local registration goodness estimates. The resulting accuracy is clinically acceptable, at least for these atlas patients.


Asunto(s)
Algoritmos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Imagen por Resonancia Magnética , Planificación de la Radioterapia Asistida por Computador , Electrones , Cabeza , Humanos , Tomografía Computarizada por Rayos X
20.
Int J Radiat Oncol Biol Phys ; 98(2): 454-462, 2017 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-28463165

RESUMEN

PURPOSE: To develop and evaluate a super-resolution approach to reconstruct time-resolved 4-dimensional magnetic resonance imaging (TR-4DMRI) with a high spatiotemporal resolution for multi-breathing cycle motion assessment. METHODS AND MATERIALS: A super-resolution approach was developed to combine fast 3-dimensional (3D) cine MRI with low resolution during free breathing (FB) and high-resolution 3D static MRI during breath hold (BH) using deformable image registration. A T1-weighted, turbo field echo sequence, coronal 3D cine acquisition, partial Fourier approximation, and SENSitivity Encoding parallel acceleration were used. The same MRI pulse sequence, field of view, and acceleration techniques were applied in both FB and BH acquisitions; the intensity-based Demons deformable image registration method was used. Under an institutional review board-approved protocol, 7 volunteers were studied with 3D cine FB scan (voxel size: 5 × 5 × 5 mm3) at 2 Hz for 40 seconds and a 3D static BH scan (2 × 2 × 2 mm3). To examine the image fidelity of 3D cine and super-resolution TR-4DMRI, a mobile gel phantom with multi-internal targets was scanned at 3 speeds and compared with the 3D static image. Image similarity among 3D cine, 4DMRI, and 3D static was evaluated visually using difference image and quantitatively using voxel intensity correlation and Dice index (phantom only). Multi-breathing-cycle waveforms were extracted and compared in both phantom and volunteer images using the 3D cine as the references. RESULTS: Mild imaging artifacts were found in the 3D cine and TR-4DMRI of the mobile gel phantom with a Dice index of >0.95. Among 7 volunteers, the super-resolution TR-4DMRI yielded high voxel-intensity correlation (0.92 ± 0.05) and low voxel-intensity difference (<0.05). The detected motion differences between TR-4DMRI and 3D cine were -0.2 ± 0.5 mm (phantom) and -0.2 ± 1.9 mm (diaphragms). CONCLUSION: Super-resolution TR-4DMRI has been reconstructed with adequate temporal (2 Hz) and spatial (2 × 2 × 2 mm3) resolutions. Further TR-4DMRI characterization and improvement are necessary before clinical applications. Multi-breathing cycles can be examined, providing patient-specific breathing irregularities and motion statistics for future 4D radiation therapy.


Asunto(s)
Contencion de la Respiración , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Movimiento , Respiración , Artefactos , Análisis de Fourier , Humanos , Imagenología Tridimensional/normas , Imagen por Resonancia Cinemagnética/normas , Movimiento (Física) , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA