Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Micromachines (Basel) ; 14(3)2023 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-36985016

RESUMEN

Aimed at the problems of a large equipment size, long time and high price of environmental VOC gas detection, the FAIMS-VOC gas sensor was designed and prepared according to the principle that the ionization energy of the common VOC gas is less than 10.6 eV. The sensor is small in size, fast in detection, low in power consumption, and can work continuously. The sensor was fabricated through the MEMS process, a specific process which included photolithography, etching, anodic bonding, etc. The sensor is 5160 µm long, 5300 µm wide and 800 µm high. We built a test system to detect two typical VOC gases: isobutylene and acetone. The results show that in the detection of isobutylene gas and acetone gas, the sensor voltage value changes with the change of gas concentration. The linearity of testing isobutylene is 0.961, and the linearity of testing acetone is 0.987. When the isobutylene gas concentration is 50 ppm, the response time is 8 s and the recovery time is 6 s; when the acetone gas concentration is 50 ppm, the response time is 9 s and the recovery time is 10 s. In addition, the sensor demonstrates good repeatability and stability, which are conducive to the detection of VOCs in the environment.

2.
Micromachines (Basel) ; 13(4)2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35457809

RESUMEN

Based on the humidity testing requirements in different environments, this paper investigates the humidity sensitivity of reduced graphene oxide (rGO)-sodium dodecyl sulfate (SDS) composite film humidity sensor. In the experiments, rGO-SDS dispersions with a concentration of 5 mg/mL were prepared, and a microelectromechanical system (MEMS) process was used to prepare the interdigital electrodes. The dispersions were then drop-coated on the interdigital electrodes and dried on a heated plate at 100 °C. The surface characteristics of the rGO-SDS films transferred onto SiO2-Si substrates were analyzed by scanning electron microscopy, raman spectroscopy and atomic force microscopy, infrared spectroscopy, X-ray photoelectron spectroscopy, and tested by a correlation system, which showed a linear relationship between humidity variation and the resistance variation of the sensor in the ambient humidity range of 25-95% RH. At room temperature, the linearity of the sensor is about 0.98431 and the sensitivity is about 11.41432 Ω/% RH. At 100 °C, the correlation of the sensor is about 0.95046 and the sensitivity is about 1.0145 Ω/% RH; with a response time of only 9 s at ambient humidity from 25% RH to 95% RH, the sensor has very good repeatability and stability.

3.
Micromachines (Basel) ; 12(12)2021 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-34945383

RESUMEN

In this paper, to address the problems of large blood draws, long testing times, and the inability to achieve dynamic detection of invasive testing for diabetes, stemming from the principle that type 1 diabetic patients exhale significantly higher levels of acetone than normal people, a FAIMS-MEMS gas sensor was designed to detect acetone, which utilizes the characteristics of high sensitivity, fast response, and non-invasive operation. It is prepared by MEMS processes, such as photolithography, etching, and sputtering, its specific dimensions are 4000 µm in length, 3000 µm in width and 800 µm in height and the related test system was built to detect acetone gas. The test results show that when acetone below 0.8 ppm is introduced, the voltage value detected by the sensor basically does not change, while when acetone gas exceeds 1.8 ppm, the voltage value detected by the sensor increases significantly. The detection accuracy of the sensor prepared by this method is about 0.02 ppm/mV, and the voltage change can reach 1 V with a response time of 3 s and a recovery time of 4 s when tested under 20 ppm acetone environment; this has good repeatability and stability, and has great prospects in the field of non-invasive detection of type 1 diabetes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA