1.
Ann Surg Oncol ; 30(7): 4097-4108, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37041429

RESUMEN

BACKGROUND: Breast-conserving surgery (BCS) is an integral component of early-stage breast cancer treatment, but costly reexcision procedures are common due to the high prevalence of cancer-positive margins on primary resections. A need exists to develop and evaluate improved methods of margin assessment to detect positive margins intraoperatively. METHODS: A prospective trial was conducted through which micro-computed tomography (micro-CT) with radiological interpretation by three independent readers was evaluated for BCS margin assessment. Results were compared to standard-of-care intraoperative margin assessment (i.e., specimen palpation and radiography [abbreviated SIA]) for detecting cancer-positive margins. RESULTS: Six hundred margins from 100 patients were analyzed. Twenty-one margins in 14 patients were pathologically positive. On analysis at the specimen-level, SIA yielded a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 42.9%, 76.7%, 23.1%, and 89.2%, respectively. SIA correctly identified six of 14 margin-positive cases with a 23.5% false positive rate (FPR). Micro-CT readers achieved sensitivity, specificity, PPV, and NPV ranges of 35.7-50.0%, 55.8-68.6%, 15.6-15.8%, and 86.8-87.3%, respectively. Micro-CT readers correctly identified five to seven of 14 margin-positive cases with an FPR range of 31.4-44.2%. If micro-CT scanning had been combined with SIA, up to three additional margin-positive specimens would have been identified. DISCUSSION: Micro-CT identified a similar proportion of margin-positive cases as standard specimen palpation and radiography, but due to difficulty distinguishing between radiodense fibroglandular tissue and cancer, resulted in a higher proportion of false positive margin assessments.


Asunto(s)
Neoplasias de la Mama , Mastectomía Segmentaria , Humanos , Femenino , Mastectomía Segmentaria/métodos , Microtomografía por Rayos X/métodos , Estudios Prospectivos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Radiografía , Márgenes de Escisión
2.
Breast Cancer Res Treat ; 183(2): 403-410, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32656723

RESUMEN

PURPOSE: Little is known about the three-dimensional shape of breast cancer. Implicit to approaches that localize the center of the tumor for breast-conserving surgery (BCS) of non-palpable cancers is the assumption that breast cancers are spherical about a central point, which may not be accurate. METHODS: Pre-operative supine breast MRI images were obtained of 83 breast cancer patients undergoing partial mastectomy using supine MRI-guided resection techniques. Three-dimensional (3D) tumor models were derived after radiologists outlined tumor edges on successive MRI slices. Ideal resection volumes were determined by adding 1 cm in every dimension to the actual tumor volume. Geometrically defined parameters were used to define tumor shapes and associations between clinical variables and shapes were examined. RESULTS: Seventy-five patients had invasive cancer. Breast cancers were categorized into four tumor shapes: 34% of tumors were discoidal, 29% segmental, 19% spherical, and 18% irregular. If hypothetical spherical excisions were performed, non-spherical cases would excise 143% more tissue than the ideal resection volume. When the 3D shape of each tumor was provided to the surgeon during MR-guided BCS, the percentage of tissue overexcised in non-spherical cases was significantly less (143% vs. 66%, p < 0.001). CONCLUSIONS: Information obtained from a supine MRI can be used to generate 3D tumor models and rapidly classify breast tumor shapes. The vast majority of invasive cancers and DCIS are not spherical. Knowledge of tumor shape may allow surgeons to excise breast cancer more precisely.


Asunto(s)
Neoplasias de la Mama/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Mastectomía Segmentaria/métodos , Mastectomía/métodos , Carga Tumoral , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Femenino , Humanos , Persona de Mediana Edad
3.
Ann Surg Oncol ; 26(10): 3099-3108, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31359283

RESUMEN

BACKGROUND: Wire-localized excision of non-palpable breast cancer is imprecise, resulting in positive margins 15-35% of the time. METHODS: Women with a confirmed diagnosis of non-palpable invasive breast cancer (IBC) or ductal carcinoma in situ (DCIS) were randomized to a new technique using preoperative supine magnetic resonance imaging (MRI) with intraoperative optical scanning and tracking (MRI group) or wire-localized (WL group) partial mastectomy. The main outcome measure was the positive margin rate. RESULTS: In this study, 138 patients were randomly assigned. Sixty-six percent had IBC and DCIS, 22% had IBC, and 12% had DCIS. There were no differences in patient or tumor characteristics between the groups. The proportion of patients with positive margins in the MRI-guided surgery group was half that observed in the WL group (12 vs. 23%; p = 0.08). The specimen volumes in the MRI and WL groups did not differ significantly (74 ± 33.9 mL vs. 69.8 ± 25.1 mL; p = 0.45). The pathologic tumor diameters were underestimated by 2 cm or more in 4% of the cases by MRI and in 9% of the cases by mammography. Positive margins were observed in 68% and 58% of the cases underestimated by 2 cm or more using MRI and mammography, respectively, and in 15% and 14% of the cases not underestimated using MRI and mammography, respectively. CONCLUSIONS: A novel system using supine MRI images co-registered with intraoperative optical scanning and tracking enabled tumors to be resected with a trend toward a lower positive margin rate compared with wire-localized partial mastectomy. Margin positivity was more likely when imaging underestimated pathologic tumor size.


Asunto(s)
Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante/cirugía , Carcinoma Lobular/cirugía , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Mastectomía Segmentaria/métodos , Neoplasias de la Mama/patología , Carcinoma Ductal de Mama/patología , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Lobular/patología , Femenino , Estudios de Seguimiento , Humanos , Márgenes de Escisión , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos
4.
Breast Cancer Res Treat ; 172(3): 587-595, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30225621

RESUMEN

BACKGROUND: Roughly 23% of breast conserving surgery (BCS) patients undergo a second re-excision procedure due to pathologically positive surgical margins. We investigated the feasibility and potential value of micro-Computed Tomography (micro-CT) as a surgical margin guidance tool during BCS. METHODS: A cohort of 32 BCS specimens was prospectively imaged with a pre-clinical micro-CT system upon arrival in the surgical pathology laboratory. Reconstructed micro-CT scans were evaluated retrospectively by an experienced breast radiologist, who provided binary determinations whether lesions extended to the specimen margin. These readings were then compared to the final pathological diagnosis and to 2D specimen radiography readings. RESULTS: Of the 32 specimens imaged, 28 had malignant and four had benign pathological diagnoses. Overall five (four malignant, one benign) of the 32 specimens had lesion tissue extending to the margin. For all 32 specimens, micro-CT reconstructions were calculated (< 4 min. acquisition + reconstruction time) and each specimen was volumetrically analyzed by a radiologist. Of the 28 malignant specimen readings, 18 matched the final pathological diagnosis [64%, 95 CI (47%-81%)], with a negative predictive value of 89% [95 CI (74%-96%)]. Micro-CT readings revealed changes in the tumor location and margin status as compared to single-projection radiography readings. CONCLUSIONS: Micro-CT scanning of BCS specimens enabled margin status assessment over the entirety of the surgical surface in a clinically relevant time frame, provided additional spatial information over single-projection radiography, and may be a potentially useful BCS guidance tool.


Asunto(s)
Neoplasias de la Mama/cirugía , Mastectomía Segmentaria/métodos , Microtomografía por Rayos X/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Carcinoma Intraductal no Infiltrante/diagnóstico por imagen , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/cirugía , Femenino , Humanos , Mamografía
6.
Ann Surg Oncol ; 24(10): 2950-2956, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28766199

RESUMEN

BACKGROUND: Wire-localized excision of nonpalpable breast cancer is imprecise, resulting in positive margins 25-30% of the time. METHODS: Patients underwent preoperative supine magnetic resonance imaging (MRI). A radiologist outlined the tumor edges on consecutive images, creating a three-dimensional (3D) view of its location. Using 3D printing, a bra-like plastic form (the Breast Cancer Locator [BCL]) was fabricated, with features that allowed a surgeon to (1) mark the edges of the tumor on the breast surface; (2) inject blue dye into the breast 1 cm from the tumor edges; and (3) place a wire in the tumor at the time of surgery. RESULTS: Nineteen patients with palpable cancers underwent partial mastectomy after placement of surgical cues using patient-specific BCLs. The cues were in place in <5 min and no adverse events occurred. The BCL accurately localized 18/19 cancers. In the 18 accurately localized cases, all 68 blue-dye injections were outside of the tumor edges. Median distance from the blue-dye center to the pathologic tumor edge was 1.4 cm, while distance from the blue dye to the tumor edge was <5 mm in 4% of injections, 0.5-2.0 cm in 72% of injections, and >2 cm in 24% of injections. Median distance from the tumor center to the BCL-localized wire and to the clip placed at the time of diagnosis was similar (0.49 vs. 0.73 cm) on specimen mammograms. CONCLUSIONS: Information on breast cancer location and shape derived from a supine MRI can be transferred safely and accurately to patients in the operating room using a 3D-printed form.


Asunto(s)
Neoplasias de la Mama/patología , Carcinoma Ductal de Mama/patología , Carcinoma Intraductal no Infiltrante/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Mastectomía Segmentaria , Cirugía Asistida por Computador/métodos , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante/cirugía , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Invasividad Neoplásica , Estadificación de Neoplasias , Posición Supina
8.
Radiol Case Rep ; 16(11): 3285-3288, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34484532

RESUMEN

We report a case of breast cancer in a transgender woman (assigned male sex at birth, gender identity female) of Ashkenazi Jewish descent with BRCA2 mutation who had been taking cross-sex hormone therapy for 2 years. In addition to demonstrating breast cancer imaging findings and risk factors, this case draws attention to the paucity of research and data regarding breast cancer in transgender women and exemplifies the need for evidence-based consensus breast cancer screening recommendations for transgender women.

9.
Sci Rep ; 11(1): 21832, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-34750471

RESUMEN

High positive margin rates in oncologic breast-conserving surgery are a pressing clinical problem. Volumetric X-ray scanning is emerging as a powerful ex vivo specimen imaging technique for analyzing resection margins, but X-rays lack contrast between non-malignant and malignant fibrous tissues. In this study, combined micro-CT and wide-field optical image radiomics were developed to classify malignancy of breast cancer tissues, demonstrating that X-ray/optical radiomics improve malignancy classification. Ninety-two standardized features were extracted from co-registered micro-CT and optical spatial frequency domain imaging samples extracted from 54 breast tumors exhibiting seven tissue subtypes confirmed by microscopic histological analysis. Multimodal feature sets improved classification performance versus micro-CT alone when adipose samples were included (AUC = 0.88 vs. 0.90; p-value = 3.65e-11) and excluded, focusing the classification task on exclusively non-malignant fibrous versus malignant tissues (AUC = 0.78 vs. 0.85; p-value = 9.33e-14). Extending the radiomics approach to high-dimensional optical data-termed "optomics" in this study-offers a promising optical image analysis technique for cancer detection. Radiomic feature data and classification source code are publicly available.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mastectomía Segmentaria/métodos , Imagen Óptica/métodos , Microtomografía por Rayos X/métodos , Tejido Adiposo/diagnóstico por imagen , Neoplasias de la Mama/clasificación , Femenino , Humanos , Técnicas In Vitro , Márgenes de Escisión , Imagen Multimodal/instrumentación , Imagen Multimodal/métodos , Imagen Multimodal/estadística & datos numéricos , Imagen Óptica/instrumentación , Imagen Óptica/estadística & datos numéricos , Fenómenos Ópticos , Procesos Estocásticos , Microtomografía por Rayos X/instrumentación , Microtomografía por Rayos X/estadística & datos numéricos
10.
Phys Med Biol ; 66(11)2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34061046

RESUMEN

In patients undergoing breast-conserving surgery (BCS), the rate of re-excision procedures to remove residual tumor left behind after initial resection can be high. Projection radiography, and recently, volumetric x-ray imaging are used to assess margin adequacy, but x-ray imaging lacks contrast between healthy, abnormal benign, and malignant fibrous tissues important for surgical decision making. The purpose of this study was to compare micro-CT and optical scatter imagery of surgical breast specimens and to demonstrate enhanced contrast-to intra-tumoral morphologies and tumor boundary features revealed by optical scatter imaging. A total of 57 breast tumor slices from 57 patients were imagedex vivoby spatially co-registered micro-CT and optical scatter scanning. Optical scatter exhibited greater similarity with micro-CT in 89% (51/57) of specimens versus diffuse white light (DWL) luminance using mutual information (mean ± standard deviation of 0.48 ± 0.21 versus 0.24 ± 0.12;p < 0.001) and in 81% (46/57) of specimens using the Sørensen-Dice coefficient (0.48 ± 0.21 versus 0.33 ± 0.18;p < 0.001). The coefficient of variation (CV) quantified the feature content in each image. Optical scatter exhibited the highest CV in every specimen (optical scatter: 0.70 ± 0.17; diffuse luminance: 0.24 ± 01; micro-CT: 0.15 ± 0.03 for micro-CT;p < 0.001). Optical scatter also exhibited the highest contrast ratios across representative tumor boundaries with adjacent healthy/benign fibrous tissues (1.5-3.7 for optical scatter; 1.0-1.1 for diffuse luminance; 1.0-1.1 for micro-CT). The two main findings from this study were: first, optical scatter contrast was in general similar to the radiological view of the tissue relative to DWL imaging; and second, optical scatter revealed additional features associated with fibrous tissue structures of similar radiodensity that may be relevant to diagnosis. The value of micro-CT lies in its rapid three-dimensional scanning of specimen morphology, and combined with optical scatter imaging with sensitivity to fibrous surface tissues, may be an attractive solution for margin assessment during BCS.


Asunto(s)
Neoplasias de la Mama , Mama , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Femenino , Humanos , Márgenes de Escisión , Mastectomía Segmentaria , Microtomografía por Rayos X
11.
Front Oncol ; 11: 743256, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34660306

RESUMEN

OBJECTIVE: The overall objective of this clinical study was to validate an implantable oxygen sensor, called the 'OxyChip', as a clinically feasible technology that would allow individualized tumor-oxygen assessments in cancer patients prior to and during hypoxia-modification interventions such as hyperoxygen breathing. METHODS: Patients with any solid tumor at ≤3-cm depth from the skin-surface scheduled to undergo surgical resection (with or without neoadjuvant therapy) were considered eligible for the study. The OxyChip was implanted in the tumor and subsequently removed during standard-of-care surgery. Partial pressure of oxygen (pO2) at the implant location was assessed using electron paramagnetic resonance (EPR) oximetry. RESULTS: Twenty-three cancer patients underwent OxyChip implantation in their tumors. Six patients received neoadjuvant therapy while the OxyChip was implanted. Median implant duration was 30 days (range 4-128 days). Forty-five successful oxygen measurements were made in 15 patients. Baseline pO2 values were variable with overall median 15.7 mmHg (range 0.6-73.1 mmHg); 33% of the values were below 10 mmHg. After hyperoxygenation, the overall median pO2 was 31.8 mmHg (range 1.5-144.6 mmHg). In 83% of the measurements, there was a statistically significant (p ≤ 0.05) response to hyperoxygenation. CONCLUSIONS: Measurement of baseline pO2 and response to hyperoxygenation using EPR oximetry with the OxyChip is clinically feasible in a variety of tumor types. Tumor oxygen at baseline differed significantly among patients. Although most tumors responded to a hyperoxygenation intervention, some were non-responders. These data demonstrated the need for individualized assessment of tumor oxygenation in the context of planned hyperoxygenation interventions to optimize clinical outcomes.

12.
Front Oncol ; 10: 572060, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33194670

RESUMEN

Introduction: Tumor hypoxia confers both a poor prognosis and increased resistance to oncologic therapies, and therefore, hypoxia modification with reliable oxygen profiling during anticancer treatment is desirable. The OxyChip is an implantable oxygen sensor that can detect tumor oxygen levels using electron paramagnetic resonance (EPR) oximetry. We report initial safety and feasibility outcomes after OxyChip implantation in a first-in-humans clinical trial (NCT02706197, www.clinicaltrials.gov). Materials and Methods: Twenty-four patients were enrolled. Eligible patients had a tumor ≤ 3 cm from the skin surface with planned surgical resection as part of standard-of-care therapy. Most patients had a squamous cell carcinoma of the skin (33%) or a breast malignancy (33%). After an initial cohort of six patients who received surgery alone, eligibility was expanded to patients receiving either chemotherapy or radiotherapy prior to surgical resection. The OxyChip was implanted into the tumor using an 18-G needle; a subset of patients had ultrasound-guided implantation. Electron paramagnetic resonance oximetry was carried out using a custom-built clinical EPR scanner. Patients were evaluated for associated toxicity using the Common Terminology Criteria for Adverse Events (CTCAE); evaluations started immediately after OxyChip placement, occurred during every EPR oximetry measurement, and continued periodically after removal. The OxyChip was removed during standard-of-care surgery, and pathologic analysis of the tissue surrounding the OxyChip was performed. Results: Eighteen patients received surgery alone, while five underwent chemotherapy and one underwent radiotherapy prior to surgery. No unanticipated serious adverse device events occurred. The maximum severity of any adverse event as graded by the CTCAE was 1 (least severe), and all were related to events typically associated with implantation. After surgical resection, 45% of the patients had no histopathologic findings specifically associated with the OxyChip. All tissue pathology was "anticipated" excepting a patient with greater than expected inflammatory findings, which was assessed to be related to the tumor as opposed to the OxyChip. Conclusion: This report of the first-in-humans trial of OxyChip implantation and EPR oximetry demonstrated no significant clinical pathology or unanticipated serious adverse device events. Use of the OxyChip in the clinic was thus safe and feasible.

SELECCIÓN DE REFERENCIAS