Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 59(1): 223-230, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37144669

RESUMEN

BACKGROUND: Different Circle of Willis (CoW) variants have variable prevalences of aneurysm development, but the hemodynamic variation along the CoW and its relation to presence and size of unruptured intracranial aneurysms (UIAs) are not well known. PURPOSE: Gain insight into hemodynamic imaging markers of the CoW for UIA development by comparing these outcomes to the corresponding contralateral artery without an UIA using 4D flow magnetic resonance imaging (MRI). STUDY TYPE: Retrospective, cross-sectional study. SUBJECTS: Thirty-eight patients with an UIA, whereby 27 were women and a mean age of 62 years old. FIELD STRENGTH/SEQUENCE: Four-dimensional phase-contrast (PC) MRI with a 3D time-resolved velocity encoded gradient echo sequence at 7 T. ASSESSMENT: Hemodynamic parameters (blood flow, velocity pulsatility index [vPI], mean velocity, distensibility, and wall shear stress [peak systolic (WSSMAX ), and time-averaged (WSSMEAN )]) in the parent artery of the UIA were compared to the corresponding contralateral artery without an UIA and were related to UIA size. STATISTICAL TESTS: Paired t-tests and Pearson Correlation tests. The threshold for statistical significance was P < 0.05 (two-tailed). RESULTS: Blood flow, mean velocity, WSSMAX , and WSSMEAN were significantly higher, while vPI was lower, in the parent artery relative to contralateral artery. The WSSMAX of the parent artery significantly increased linearly while the WSSMEAN decreased linearly with increasing UIA size. CONCLUSIONS: Hemodynamic parameters and WSS differ between parent vessels of UIAs and corresponding contralateral vessels. WSS correlates with UIA size, supporting a potential hemodynamic role in aneurysm pathology. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Aneurisma Intracraneal , Humanos , Femenino , Persona de Mediana Edad , Masculino , Aneurisma Intracraneal/diagnóstico por imagen , Estudios Retrospectivos , Estudios Transversales , Imagen por Resonancia Magnética , Hemodinámica/fisiología , Arterias
2.
J Magn Reson Imaging ; 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38006298

RESUMEN

BACKGROUND: Maximum diameter measurements are used to assess the rupture risk of abdominal aortic aneurysms (AAAs); however, these are not precise enough to predict all ruptures. Four-dimensional (4D) flow MRI-derived parameters provide additional information by visualizing hemodynamics in AAAs but merit further investigation before they are clinically applicable. PURPOSE: To assess the reproducibility of 4D flow MRI-derived hemodynamics, to investigate possible correlations with lumen and maximum diameter, and to explore potential relationships with vorticity and aneurysm growth. STUDY TYPE: Prospective single-arm study. POPULATION: A total of 22 (71.5 ± 6.1 years, 20 male) asymptomatic AAA patients with a maximum diameter of at least 30 mm. FIELD STRENGTH/SEQUENCE: A 3.0 T/Free-breathing 4D flow MRI phase-contrast acquisition with retrospective ECG-gating. ASSESSMENT: Patients underwent two consecutive 4D flow MRI scans 1-week apart. Aortic volumes were segmented from time-averaged phase contrast magnetic resonance angiographies. Reproducibility was assessed by voxelwise analysis after registration. Mean flow velocity, mean wall shear stress (WSS), mean lumen diameter, and qualitative vorticity scores were assessed. In addition, Dixon MRI and retrospective surveillance data were used to study maximum diameter (including thrombus), intraluminal thrombus volume (ILT), and growth rate. STATISTICAL TESTS: For reproducibility assessment, Bland-Altman analyses, Pearson correlation, Spearman's correlation, and orthogonal regression were conducted. Potential correlations between hemodynamics and vorticity scores were assessed using linear regression. P < 0.05 was considered statistically significant. RESULTS: Test-retest median Pearson correlation coefficients for flow velocity and WSS were 0.85 (IQR = 0.08) m/sec and 0.82 (IQR = 0.10) Pa, respectively. Mean WSS significantly correlated with mean flow velocity (R = 0.75) and inversely correlated with mean lumen diameter (R = -0.73). No significant associations were found between 4D flow MRI-derived hemodynamic parameters and maximum diameter (flow velocity: P = 0.98, WSS: P = 0.22). DATA CONCLUSION: A 4D flow MRI is robust for assessing the hemodynamics within AAAs. No correlations were found between hemodynamic parameters and maximum diameter, ILT volume and growth rate. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

3.
J Endovasc Ther ; : 15266028231204830, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37853734

RESUMEN

PURPOSE: In current practice, the diameter of an aortic aneurysm is utilized to estimate the rupture risk and decide upon timing of elective repair, although it is known to be imprecise and not patient-specific. Quantitative magnetic resonance imaging (MRI) enables the visualization of several biomarkers that provide information about processes within the aneurysm and may therefore facilitate patient-specific risk stratification. We performed a scoping review of the literature on quantitative MRI techniques to assess aortic aneurysm progression and rupture risk, summarized these findings, and identified knowledge gaps. METHODS: Literature concerning primary research was of interest and the medical databases PubMed, Scopus, Embase, and Cochrane were systematically searched. This study used the PRISMA protocol extension for scoping reviews. Articles published between January 2010 and February 2023 involving animals and/or humans were included. Data were extracted by 2 authors using a predefined charting method. RESULTS: A total of 1641 articles were identified, of which 21 were included in the scoping review. Quantitative MRI-derived biomarkers were categorized into hemodynamic (8 studies), wall (5 studies) and molecular biomarkers (8 studies). Fifteen studies included patients and/or healthy human subjects. Animal models were investigated in the other 6 studies. A cross-sectional study design was the most common, whereas 5 animal studies had a longitudinal component and 2 studies including patients had a prospective design. A promising hemodynamic biomarker is wall shear stress (WSS), which is estimated based on 4D-flow MRI. Molecular biomarkers enable the assessment of inflammatory and wall deterioration processes. The ADAMTS4-specific molecular magnetic resonance (MR) probe showed potential to predict abdominal aortic aneurysm (AAA) formation and rupture in a murine model. Wall biomarkers assessed using dynamic contrast-enhanced (DCE) MRI showed great potential for assessing AAA progression independent of the maximum diameter. CONCLUSION: This scoping review provides an overview of quantitative MRI techniques studied and the biomarkers derived from them to assess aortic aneurysm progression and rupture risk. Longitudinal studies are needed to validate the causal relationships between the identified biomarkers and aneurysm growth, rupture, or repair. In the future, quantitative MRI could play an important role in the personalized risk assessment of aortic aneurysm rupture. CLINICAL IMPACT: The currently used maximum aneurysm diameter fails to accurately assess the multifactorial pathology of an aortic aneurysm and precisely predicts rupture in a patient-specific manner. Quantitative magnetic resonance imaging (MRI) enables the detection of various quantitative parameters involved in aneurysm progression and subsequent rupture. This scoping review provides an overview of the studied quantitative MRI techniques, the biomarkers derived from them, and recommendations for future research needed for the implementation of these biomarkers. Ultimately, quantitative MRI could facilitate personalized risk assessment for patients with aortic aneurysms, thereby reducing untimely repairs and improving rupture prevention.

4.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-37474977

RESUMEN

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Asunto(s)
Sistema Cardiovascular , Humanos , Velocidad del Flujo Sanguíneo , Valor Predictivo de las Pruebas , Corazón , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
5.
J Magn Reson Imaging ; 55(4): 1120-1130, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34510612

RESUMEN

BACKGROUND: Pseudo-spiral Cartesian sampling with compressed sensing reconstruction has facilitated highly accelerated 4D flow magnetic resonance imaging (MRI) in various cardiovascular structures. However, unlike echo planar imaging (EPI)-accelerated 4D flow MRI, it has not been validated in whole-heart applications. HYPOTHESIS: Pseudo-spiral 4D flow MRI (PROUD [PROspective Undersampling in multiple Dimensions]) is comparable to EPI in robustness of valvular flow measurements and remains comparable as the undersampling factor is increased and scan time reduced. STUDY TYPE: Prospective. POPULATION: Twelve healthy subjects and eight patients with valvular regurgitation. FIELD STRENGTH/SEQUENCE: 3.0 T; PROUD and EPI 4D flow sequences, 2D flow and balanced steady-state free precession sequences. ASSESSMENT: Valvular blood flow was quantified using valve tracking. PROUD- and EPI-based measurements of aortic (AV) and pulmonary (PV) flow volumes and left and right ventricular stroke volumes were tested for agreement with 2D MRI-based measurements. PROUD reconstructions with undersampling factors (R) of 9, 14, 28, and 56 were tested for intervalve consistency (per valve, compared to the other valves) and preservation of peak velocities and E/A ratios. STATISTICAL TESTS: We used repeated measures ANOVA, Bland-Altman, Wilcoxon signed rank, and intraclass correlation coefficients. P < 0.05 was considered statistically significant. RESULTS: PROUD and EPI intervalve consistencies were not significantly different both in healthy subjects (valve-averaged mean difference [limits of agreement width]: 3.2 ± 0.8 [8.7 ± 1.1] mL/beat for PROUD, 5.5 ± 2.9 [13.7 ± 2.3] mL/beat for EPI, P = 0.07) and in patients with valvular regurgitation (2.3 ± 1.2 [15.3 ± 5.9] mL/beat for PROUD, 0.6 ± 0.6 [19.3 ± 2.9] mL/beat for EPI, P = 0.47). Agreement between EPI and PROUD was higher than between 4D flow (EPI or PROUD) and 2D MRI for forward flow, stroke volumes, and regurgitant volumes. Up to R = 28 in healthy subjects and R = 14 in patients with valvular regurgitation, PROUD intervalve consistency remained comparable to that of EPI. Peak velocities and E/A ratios were preserved up to R = 9. CONCLUSION: PROUD is comparable to EPI in terms of intervalve consistency and may be used with higher undersampling factors to shorten scan times further. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Imagen Eco-Planar , Imagen por Resonancia Magnética , Velocidad del Flujo Sanguíneo , Humanos , Imagenología Tridimensional/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico , Función Ventricular Derecha
6.
J Magn Reson Imaging ; 54(2): 440-451, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33694310

RESUMEN

BACKGROUND: Respiratory gating is generally recommended in 4D flow MRI of the heart to avoid blurring and motion artifacts. Recently, a novel automated contact-less camera-based respiratory motion sensor has been introduced. PURPOSE: To compare camera-based respiratory gating (CAM) with liver-lung-navigator-based gating (NAV) and no gating (NO) for whole-heart 4D flow MRI. STUDY TYPE: Retrospective. SUBJECTS: Thirty two patients with a spectrum of cardiovascular diseases. FIELD STRENGTH/SEQUENCE: A 3T, 3D-cine spoiled-gradient-echo-T1-weighted-sequence with flow-encoding in three spatial directions. ASSESSMENT: Respiratory phases were derived and compared against each other by cross-correlation. Three radiologists/cardiologist scored images reconstructed with camera-based, navigator-based, and no respiratory gating with a 4-point Likert scale (qualitative analysis). Quantitative image quality analysis, in form of signal-to-noise ratio (SNR) and liver-lung-edge (LLE) for sharpness and quantitative flow analysis of the valves were performed semi-automatically. STATISTICAL TESTS: One-way repeated measured analysis of variance (ANOVA) with Wilks's lambda testing and follow-up pairwise comparisons. Significance level of P ≤ 0.05. Krippendorff's-alpha-test for inter-rater reliability. RESULTS: The respiratory signal analysis revealed that CAM and NAV phases were highly correlated (C = 0.93 ± 0.09, P < 0.01). Image scoring showed poor inter-rater reliability and no significant differences were observed (P ≥ 0.16). The image quality comparison showed that NAV and CAM were superior to NO with higher SNR (P = 0.02) and smaller LLE (P < 0.01). The quantitative flow analysis showed significant differences between the three respiratory-gated reconstructions in the tricuspid and pulmonary valves (P ≤ 0.05), but not in the mitral and aortic valves (P > 0.05). Pairwise comparisons showed that reconstructions without respiratory gating were different in flow measurements to either CAM or NAV or both, but no differences were found between CAM and NAV reconstructions. DATA CONCLUSION: Camera-based respiratory gating performed as well as conventional liver-lung-navigator-based respiratory gating. Quantitative image quality analysis showed that both techniques were equivalent and superior to no-gating-reconstructions. Quantitative flow analysis revealed local flow differences (tricuspid/pulmonary valves) in images of no-gating-reconstructions, but no differences were found between images reconstructed with camera-based and navigator-based respiratory gating. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Imagen por Resonancia Magnética , Técnicas de Imagen Sincronizada Respiratorias , Artefactos , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
7.
J Cardiovasc Magn Reson ; 23(1): 9, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-33588887

RESUMEN

BACKGROUND: Helices and vortices in thoracic aortic blood flow measured with 4D flow cardiovascular magnetic resonance (CMR) have been associated with aortic dilation and aneurysms. Current approaches are semi-quantitative or when fully quantitative based on 2D plane placement. In this study, we present a fully quantitative and three-dimensional approach to map and quantify abnormal velocity and wall shear stress (WSS) at peak systole in patients with a bicuspid aortic valve (BAV) of which 52% had a repaired coarctation. METHODS: 4D flow CMR was performed in 48 patients with BAV and in 25 healthy subjects at a spatiotemporal resolution of 2.5 × 2.5 × 2.5mm3/ ~ 42 ms and TE/TR/FA of 2.1 ms/3.4 ms/8° with k-t Principal Component Analysis factor R = 8. A 3D average of velocity and WSS direction was created for the normal subjects. Comparing BAV patient data with the 3D average map and selecting voxels deviating between 60° and 120° and > 120° yielded 3D maps and volume (in cm3) and surface (in cm2) quantification of abnormally directed velocity and WSS, respectively. Linear regression with Bonferroni corrected significance of P < 0.0125 was used to compare abnormally directed velocity volume and WSS surface in the ascending aorta with qualitative helicity and vorticity scores, with local normalized helicity (LNH) and quantitative vorticity and with patient characteristics. RESULTS: The velocity volumes > 120° correlated moderately with the vorticity scores (R ~ 0.50, P < 0.001 for both observers). For WSS surface these results were similar. The velocity volumes between 60° and 120° correlated moderately with LNH (R = 0.66) but the velocity volumes > 120° did not correlate with quantitative vorticity. For abnormal velocity and WSS deviating between 60° and 120°, moderate correlations were found with aortic diameters (R = 0.50-0.70). For abnormal velocity and WSS deviating > 120°, additional moderate correlations were found with age and with peak velocity (stenosis severity) and a weak correlation with gender. Ensemble maps showed that more than 60% of the patients had abnormally directed velocity and WSS. Additionally, abnormally directed velocity and WSS was higher in the proximal descending aorta in the patients with repaired coarctation than in the patients where coarctation was never present. CONCLUSION: The possibility to reveal directional abnormalities of velocity and WSS in 3D provides a new tool for hemodynamic characterization in BAV disease.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Coartación Aórtica/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Angiografía por Resonancia Magnética , Imagen de Perfusión , Adulto , Aorta Torácica/fisiopatología , Coartación Aórtica/fisiopatología , Coartación Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Estrés Mecánico , Adulto Joven
8.
Magn Reson Med ; 84(4): 2088-2102, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32162416

RESUMEN

PURPOSE: To examine the effects of age, sex, and left ventricular global function on velocity, helicity, and 3D wall shear stress (3D-WSS) in the aorta of N = 100 healthy controls. METHODS: Fifty female and 50 male volunteers with no history of cardiovascular disease, with 10 volunteers per age group (18-30, 31-40, 41-50, 51-60, and 61-80 years) underwent aortic 4D-flow MRI. Quantification of systolic aortic peak velocity, helicity, and 3D-WSS distribution and the calculation of age group-averaged peak systolic velocity and 3D-WSS maps ("atlases") were computed. Age-related and sex-related changes in peak velocity, helicity, and 3D-WSS were computed and correlated with standard metrics of left ventricular function derived from short-axis cine MRI. RESULTS: No significant differences were found in peak systolic velocity or 3D-WSS based on sex except for the 18- to 30-year-old group (males 8% higher velocity volume and 3D-WSS surface area). Between successively older groups, systolic velocity decreased (13%, <1%, 7%, and 55% of the aorta volume) and 3D-WSS decreased (21%, 2%, 30%, and 62% of the aorta surface area). Mean velocity, mean 3D-3D-WSS, and median helicity increased with cardiac output (r = 0.27-0.43, all P < .01), and mean velocity and 3D-WSS decreased with increasing diameter (r > 0.35, P < .001). Arch and descending aorta systolic mean velocity, mean 3D-WSS, and median helicity increased with normalized left ventricular volumes: end diastolic volume (r = 0.31-0.37, P < .01), end systolic volume (r = 0.27-0.35, P < .01), and stroke volume (r = 0.28-0.35, P < .01). CONCLUSION: Healthy aortic hemodynamics are dependent on subject age, and correlate with vessel diameter and cardiac function.


Asunto(s)
Aorta , Válvula Aórtica , Adolescente , Adulto , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Femenino , Hemodinámica , Humanos , Imagen por Resonancia Magnética , Masculino , Adulto Joven
9.
NMR Biomed ; 33(4): e4255, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31957927

RESUMEN

INTRODUCTION: Time-resolved three-dimensional phase contrast MRI (4D flow) of aortic blood flow requires acceleration to reduce scan time. Two established techniques for highly accelerated 4D flow MRI are k-t principal component analysis (k-t PCA) and compressed sensing (CS), which employ either regular or random k-space undersampling. The goal of this study was to gain insights into the quantitative differences between k-t PCA- and CS-derived aortic blood flow, especially for high temporal resolution CS 4D flow MRI. METHODS: The scan protocol consisted of both k-t PCA and CS accelerated 4D flow MRI, as well as a 2D flow reference scan through the ascending aorta acquired in 15 subjects. 4D flow scans were accelerated with factor R = 8. For CS accelerated scans, we used a pseudo-spiral Cartesian sampling scheme, which could additionally be reconstructed at higher temporal resolution, resulting in R = 13. 4D flow data were compared with the 2D flow scan in terms of flow, peak flow and stroke volume. A 3D peak systolic voxel-wise velocity and wall shear stress (WSS) comparison between k-t PCA and CS 4D flow was also performed. RESULTS: The mean difference in flow/peak flow/stroke volume between the 2D flow scan and the 4D flow CS with R = 8 and R = 13 was 4.2%/9.1%/3.0% and 5.3%/7.1%/1.9%, respectively, whereas for k-t PCA with R = 8 the difference was 9.7%/25.8%/10.4%. In the voxel-by-voxel 4D flow comparison we found 13.6% and 3.5% lower velocity and WSS values of k-t PCA compared with CS with R = 8, and 15.9% and 5.5% lower velocity and WSS values of k-t PCA compared with CS with R = 13. CONCLUSION: Pseudo-spiral accelerated 4D flow acquisitions in combination with CS reconstruction provides a flexible choice of temporal resolution. We showed that our proposed strategy achieves better agreement in flow values with 2D reference scans compared with using k-t PCA accelerated acquisitions.


Asunto(s)
Aorta/diagnóstico por imagen , Imagen por Resonancia Magnética , Análisis de Componente Principal , Adulto , Aorta/fisiología , Femenino , Humanos , Masculino , Estrés Mecánico , Sístole/fisiología , Factores de Tiempo
10.
J Cardiovasc Magn Reson ; 22(1): 7, 2020 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-31959203

RESUMEN

BACKGROUND: 4D flow cardiovascular magnetic resonance (CMR) enables visualization of complex blood flow and quantification of biomarkers for vessel wall disease, such as wall shear stress (WSS). Because of the inherently long acquisition times, many efforts have been made to accelerate 4D flow acquisitions, however, no detailed analysis has been made on the effect of Cartesian compressed sensing accelerated 4D flow CMR at different undersampling rates on quantitative flow parameters and WSS. METHODS: We implemented a retrospectively triggered 4D flow CMR acquisition with pseudo-spiral Cartesian k-space filling, which results in incoherent undersampling of k-t space. Additionally, this strategy leads to small jumps in k-space thereby minimizing eddy current related artifacts. The pseudo-spirals were rotated in a tiny golden-angle fashion, which provides optimal incoherence and a variable density sampling pattern with a fully sampled center. We evaluated this 4D flow protocol in a carotid flow phantom with accelerations of R = 2-20, as well as in carotids of 7 healthy subjects (27 ± 2 years, 4 male) for R = 10-30. Fully sampled 2D flow CMR served as a flow reference. Arteries were manually segmented and registered to enable voxel-wise comparisons of both velocity and WSS using a Bland-Altman analysis. RESULTS: Magnitude images, velocity images, and pathline reconstructions from phantom and in vivo scans were similar for all accelerations. For the phantom data, mean differences at peak systole for the entire vessel volume in comparison to R = 2 ranged from - 2.3 to - 5.3% (WSS) and - 2.4 to - 2.2% (velocity) for acceleration factors R = 4-20. For the in vivo data, mean differences for the entire vessel volume at peak systole in comparison to R = 10 were - 9.9, - 13.4, and - 16.9% (WSS) and - 8.4, - 10.8, and - 14.0% (velocity), for R = 20, 25, and 30, respectively. Compared to single slice 2D flow CMR acquisitions, peak systolic flow rates of the phantom showed no differences, whereas peak systolic flow rates in the carotid artery in vivo became increasingly underestimated with increasing acceleration. CONCLUSION: Acquisition of 4D flow CMR of the carotid arteries can be highly accelerated by pseudo-spiral k-space sampling and compressed sensing reconstruction, with consistent data quality facilitating velocity pathline reconstructions, as well as quantitative flow rate and WSS estimations. At an acceleration factor of R = 20 the underestimation of peak velocity and peak WSS was acceptable (< 10%) in comparison to an R = 10 accelerated 4D flow CMR reference scan. Peak flow rates were underestimated in comparison with 2D flow CMR and decreased systematically with higher acceleration factors.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Angiografía por Resonancia Magnética , Modelos Cardiovasculares , Imagen de Perfusión , Adulto , Velocidad del Flujo Sanguíneo , Arterias Carótidas/fisiología , Estudios de Factibilidad , Femenino , Voluntarios Sanos , Humanos , Angiografía por Resonancia Magnética/instrumentación , Masculino , Imagen de Perfusión/instrumentación , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Estrés Mecánico
12.
Br J Haematol ; 180(3): 432-442, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29270975

RESUMEN

Stroke risk in children with sickle cell disease (SCD) is currently assessed with routine transcranial Doppler ultrasound (TCD) measurements of blood velocity in the Circle of Willis (CoW). However, there is currently no biomarker with proven prognostic value in adult patients. Four-dimensional (4D) flow magnetic resonance imaging (MRI) may improve risk profiling based on intracranial haemodynamics. We conducted neurovascular 4D flow MRI and blood sampling in 69 SCD patients [median age 15 years (interquartile range, IQR: 12-50)] and 14 healthy controls [median age 21 years (IQR: 18-43)]. We measured velocity, flow, lumen area and endothelial shear stress (ESS) in the CoW. SCD patients had lower haematocrit and viscosity, and higher velocity, flow and lumen area, with lower ESS compared to healthy controls. We observed significant age-related decline in haemodynamic 4D flow parameters; velocity (Spearman's ρ = -0·36 to -0·61), flow (ρ = -0·26 to -0·52) and ESS (ρ = -0·14 to -0·54) in SCD patients. Further analysis in only adults showed that velocity values were similar in SCD patients compared to healthy controls, but that the additional 4D flow parameters, flow and lumen area, were higher, and ESS lower, in the SCD group. Our data suggest that 4D flow MRI may identify adult patients with an increased stroke risk more accurately than current TCD-based velocity.


Asunto(s)
Anemia de Células Falciformes/fisiopatología , Circulación Cerebrovascular , Hemodinámica , Imagen por Resonancia Magnética , Adolescente , Adulto , Factores de Edad , Anemia de Células Falciformes/sangre , Anemia de Células Falciformes/patología , Velocidad del Flujo Sanguíneo , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Estudios de Casos y Controles , Niño , Femenino , Hematócrito , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Viscosidad , Adulto Joven
13.
Magn Reson Med ; 80(5): 1799-1811, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29508449

RESUMEN

PURPOSE: 3D time-resolved (4D) phase contrast MRI can be used to study muscle contraction. However, 3D coverage with sufficient spatiotemporal resolution can only be achieved by interleaved acquisitions during many repetitions of the motion task, resulting in long scan times. The aim of this study was to develop a compressed sensing accelerated 4D phase contrast MRI technique for quantification of velocities and strain rate of the muscles in the lower leg during active plantarflexion/dorsiflexion. METHODS: Nine healthy volunteers were scanned during active dorsiflexion/plantarflexion task. For each volunteer, we acquired a reference scan, as well as 4 different accelerated scans (k-space undersampling factors: 3.14X, 4.09X, 4.89X, and 6.41X) obtained using Cartesian Poisson disk undersampling schemes. The data was reconstructed using a compressed sensing pipeline. For each scan, velocity and strain rate values were quantified in the gastrocnemius lateralis, gastrocnemius medialis, tibialis anterior, and soleus. RESULTS: No significant differences in velocity values were observed as a function acceleration factor in the investigated muscles. The strain rate calculation resulted in one positive (s+ ) and one negative (s- ) eigenvalue, whereas the third eigenvalue (s3 ) was consistently 0 for all the acquisitions. No significant differences were observed for the strain rate eigenvalues as a function of acceleration factor. CONCLUSIONS: Data undersampling combined with compressed sensing reconstruction allowed obtainment of time-resolved phase contrast acquisitions with 3D coverage and quantitative information comparable to the reference scan. The 3D sensitivity of the method can help in understanding the connection between muscle architecture and muscle function in future studies.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Contracción Muscular/fisiología , Músculo Esquelético/diagnóstico por imagen , Algoritmos , Femenino , Humanos , Pierna/diagnóstico por imagen , Masculino
14.
Magn Reson Med ; 79(1): 195-207, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28266062

RESUMEN

PURPOSE: To assess the performance of highly accelerated free-breathing aortic four-dimensional (4D) flow MRI acquired in under 2 minutes compared to conventional respiratory gated 4D flow. METHODS: Eight k-t accelerated nongated 4D flow MRI (parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisition kernels [PEAK GRAPPA], R = 5, TRes = 67.2 ms) using four ky -kz Cartesian sampling patterns (linear, center-out, out-center-out, random) and two spatial resolutions (SRes1 = 3.5 × 2.3 × 2.6 mm3 , SRes2 = 4.5 × 2.3 × 2.6 mm3 ) were compared in vitro (aortic coarctation flow phantom) and in 10 healthy volunteers, to conventional 4D flow (16 mm-navigator acceptance window; R = 2; TRes = 39.2 ms; SRes = 3.2 × 2.3 × 2.4 mm3 ). The best k-t accelerated approach was further assessed in 10 patients with aortic disease. RESULTS: The k-t accelerated in vitro aortic peak flow (Qmax), net flow (Qnet), and peak velocity (Vmax) were lower than conventional 4D flow indices by ≤4.7%, ≤ 11%, and ≤22%, respectively. In vivo k-t accelerated acquisitions were significantly shorter but showed a trend to lower image quality compared to conventional 4D flow. Hemodynamic indices for linear and out-center-out k-space samplings were in agreement with conventional 4D flow (Qmax ≤ 13%, Qnet ≤ 13%, Vmax ≤ 17%, P > 0.05). CONCLUSION: Aortic 4D flow MRI in under 2 minutes is feasible with moderate underestimation of flow indices. Differences in k-space sampling patterns suggest an opportunity to mitigate image artifacts by an optimal trade-off between scan time, acceleration, and k-space sampling. Magn Reson Med 79:195-207, 2018. © 2018 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Aorta/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Algoritmos , Aorta/patología , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Artefactos , Calibración , Femenino , Voluntarios Sanos , Hemodinámica , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Factores de Tiempo , Función Ventricular Izquierda
16.
J Magn Reson Imaging ; 48(2): 318-329, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30134000

RESUMEN

The most common types of left-sided valvular heart disease (VHD) in the Western world are aortic valve stenosis, aortic valve regurgitation, and mitral valve regurgitation. Comprehensive clinical evaluation entails both hemodynamic analysis and structural as well as functional characterization of the left ventricle. Cardiac magnetic resonance imaging (MRI) is an established diagnostic modality for assessment of left-sided VHD and is progressively gaining ground in modern-day clinical practice. Detailed flow visualization and quantification of flow-related biomarkers in VHD can be obtained using 4D flow MRI, an imaging technique capable of measuring blood flow in three orthogonal directions over time. In addition, recent MRI sequences enable myocardial tissue characterization and strain analysis. In this review we discuss the emerging potential of state-of-the-art MRI including 4D flow MRI, tissue mapping, and strain quantification for the diagnosis and prognosis of left-sided VHD. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2018. J. MAGN. RESON. IMAGING 2018;48:318-329.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Válvulas Cardíacas/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Biomarcadores , Ecocardiografía , Hemodinámica , Humanos , Imagenología Tridimensional/métodos , Cinética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Pronóstico , Resistencia al Corte , Estrés Mecánico
17.
J Magn Reson Imaging ; 48(2): 522-530, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29451963

RESUMEN

BACKGROUND: Use of 4-dimensional flow magnetic resonance imaging (4D-flow MRI) derived wall shear stress (WSS) heat maps enables identification of regions in the ascending aorta with increased WSS. These regions are subject to dysregulation of the extracellular matrix and elastic fiber degeneration, which is associated with aortic dilatation and dissection. PURPOSE: To evaluate the effect of the presence of aortic valve stenosis and the aortic diameter on the peak WSS and surface area of increased WSS in the ascending aorta. STUDY TYPE: Prospective. SUBJECTS: In all, 48 bicuspid aortic valve (BAV) patients (38.1 ± 12.4 years) and 25 age- and gender-matched healthy individuals. FIELD STRENGTH/SEQUENCE: Time-resolved 3D phase contrast MRI with three-directional velocity encoding at 3.0T. ASSESSMENT: Peak systolic velocity, WSS, and aortic diameters were assessed in the ascending aorta and 3D heat maps were used to identify regions with elevated WSS. STATISTICAL TESTS: Comparisons between groups were performed by t-tests. Correlations were investigated by univariate and multivariate regression analysis. RESULTS: Elevated WSS was present in 15 ± 11% (range; 1-35%) of the surface area of the ascending aorta of BAV patients with aortic valve stenosis (AS) (n = 10) and in 6 ± 8% (range; 0-31%) of the ascending aorta of BAV patients without AS (P = 0.005). The mid-ascending aortic diameter negatively correlated with the peak ascending aortic WSS (R = -0.413, P = 0.004) and the surface area of elevated WSS (R = -0.419, P = 0.003). Multivariate linear regression analysis yielded that the height of peak WSS and the amount of elevated WSS depended individually on the presence of aortic valve stenosis and the diameter of the ascending aorta. DATA CONCLUSION: The extent of increased WSS in the ascending aorta of BAV patients depends on the presence of aortic valve stenosis and aortic dilatation and is most pronounced in the presence of AS and a nondilated ascending aorta. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2018;48:522-530.


Asunto(s)
Aorta/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Estudios de Casos y Controles , Constricción Patológica , Dilatación , Ecocardiografía , Elasticidad , Matriz Extracelular/metabolismo , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Resistencia al Corte , Estrés Mecánico , Sístole
18.
Eur Radiol ; 28(1): 257-264, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28710578

RESUMEN

OBJECTIVES: To evaluate aortic velocity, wall shear stress (WSS) and viscous energy loss (EL) of stented and stentless bioprostheses using 4D flow MRI 1 year after surgical aortic valve replacement. METHODS: For this cross-sectional study 28 patients with stented (n = 14) or stentless (n = 14) bioprosthesis underwent non-contrast-enhanced 4D-flow MRI at 1.5 T. Analyses included a comparison of velocity, WSS and EL in the ascending aorta during peak systole for both spatially averaged values and a comparison of local differences using per-voxel analysis. RESULTS: No significant differences were found in peak and mean velocity (stented vs. stentless: 2.45 m/s vs. 2.11 m/s; p = 0.09 and 0.60 m/s vs. 0.62 m/s; p = 0.89), WSS (0.60 Pa vs. 0.59 Pa; p = 0.55) and EL (10.17 mW vs. 7.82 mW; p = 0.10). Per-voxel analysis revealed significantly higher central lumen velocity, and lower outer lumen velocity, WSS and EL for stentless versus stented prostheses. CONCLUSION: One year after aortic valve implantation with stented and stentless bioprostheses, velocity, WSS and EL were comparable when assessed for averaged values in the ascending aorta. However, the flow profile described with local analysis for stentless prosthesis is potentially favourable with a significantly higher central velocity profile and lower values for outer lumen velocity, WSS and EL. KEY POINTS: • Stentless bioprostheses can be implanted instead of stented aortic valve bioprostheses. • Haemodynamic performance of valve prosthesis can be assessed using 4D flow MRI. • Averaged ascending aorta PSV, WSS and EL are comparable 1 year post-implantation. • Centreline velocity is highest, WSS and EL is lowest for stentless prosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Stents , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Estudios Transversales , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Diseño de Prótesis , Reproducibilidad de los Resultados
19.
J Cardiovasc Magn Reson ; 20(1): 86, 2018 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-30567566

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for non-invasive assessment of arterial stiffness by means of measuring pulse wave velocity (PWV). PWV can be calculated from the time shift between two time-resolved flow curves acquired at two locations within an arterial segment. These flow curves can be derived from two-dimensional CINE phase contrast CMR (2D CINE PC CMR). While CMR-derived PWV measurements have proven to be accurate for the aorta, this is more challenging for smaller arteries such as the carotids due to the need for both high spatial and temporal resolution. In this work, we present a novel method that combines retrospectively gated 2D CINE PC CMR, high temporal binning of data and compressed sensing (CS) reconstruction to accomplish a temporal resolution of 4 ms. This enables accurate flow measurements and assessment of PWV in regional carotid artery segments. METHODS: Retrospectively gated 2D CINE PC CMR data acquired in the carotid artery was binned into cardiac frames of 4 ms length, resulting in an incoherently undersampled ky-t-space with a mean undersampling factor of 5. The images were reconstructed by a non-linear CS reconstruction using total variation over time as a sparsifying transform. PWV values were calculated from flow curves by using foot-to-foot and cross-correlation methods. Our method was validated against ultrasound measurements in a flow phantom setup representing the carotid artery. Additionally, PWV values of two groups of 23 young (30 ± 3 years, 12 [52%] women) and 10 elderly (62 ± 10 years, 5 [50%] women) healthy subjects were compared using the Wilcoxon rank-sum test. RESULTS: Our proposed method produced very similar flow curves as those measured using ultrasound at 1 ms temporal resolution. Reliable PWV estimation proved possible for transit times down to 7.5 ms. Furthermore, significant differences in PWV values between healthy young and elderly subjects were found (4.7 ± 1.0 m/s and 7.9 ± 2.4 m/s, respectively; p < 0.001) in accordance with literature. CONCLUSIONS: Retrospectively gated 2D CINE PC CMR with CS allows for high spatiotemporal resolution flow measurements and accurate regional carotid artery PWV calculations. We foresee this technique will be valuable in protocols investigating early development of carotid atherosclerosis.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Compresión de Datos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Rigidez Vascular , Adulto , Velocidad del Flujo Sanguíneo , Técnicas de Imagen Sincronizada Cardíacas , Arterias Carótidas/fisiopatología , Enfermedades de las Arterias Carótidas/fisiopatología , Electrocardiografía , Femenino , Humanos , Imagen por Resonancia Cinemagnética/instrumentación , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Ultrasonografía
20.
MAGMA ; 31(1): 201-222, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28808823

RESUMEN

The past decade has witnessed the rapid development of new MRI technology for vessel wall imaging. Today, with advances in MRI hardware and pulse sequences, quantitative MRI of the vessel wall represents a real alternative to conventional qualitative imaging, which is hindered by significant intra- and inter-observer variability. Quantitative MRI can measure several important morphological and functional characteristics of the vessel wall. This review provides a detailed introduction to novel quantitative MRI methods for measuring vessel wall dimensions, plaque composition and permeability, endothelial shear stress and wall stiffness. Together, these methods show the versatility of non-invasive quantitative MRI for probing vascular disease at several stages. These quantitative MRI biomarkers can play an important role in the context of both treatment response monitoring and risk prediction. Given the rapid developments in scan acceleration techniques and novel image reconstruction, we foresee the possibility of integrating the acquisition of multiple quantitative vessel wall parameters within a single scan session.


Asunto(s)
Angiografía por Resonancia Magnética/métodos , Placa Aterosclerótica/diagnóstico por imagen , Aterosclerosis/diagnóstico por imagen , Aterosclerosis/etiología , Aterosclerosis/fisiopatología , Fenómenos Biomecánicos , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/fisiopatología , Simulación por Computador , Medios de Contraste , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/estadística & datos numéricos , Gadolinio , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional/métodos , Imagenología Tridimensional/estadística & datos numéricos , Angiografía por Resonancia Magnética/estadística & datos numéricos , Modelos Cardiovasculares , Imagen Multimodal , Tomografía de Emisión de Positrones , Rigidez Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA