J Cardiothorac Vasc Anesth ; 37(1): 16-22, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36357305

RESUMEN

OBJECTIVES: To evaluate mitral-aortic flow velocity integral ratio (MAVIR) as an echocardiographic tool to differentiate between severe and nonsevere mitral regurgitation (MR), compared with regurgitant volume (RVol) and effective regurgitant orifice area (EROA), with subgroup analysis in patients with calcific mitral valve, both by transthoracic (TTE) and transesophageal (TEE) echocardiography. Also, whether MAVIR can be used as a screening tool for severe MR. DESIGN: Prospective, cross-sectional, observational. SETTING: Cardiac operating room of a tertiary-care hospital. PARTICIPANTS: One hundred adult patients with chronic mitral regurgitation with at least mild MR by two-dimensional Doppler and with absence of mitral stenosis, aortic valve disease, and rhythm other than sinus scheduled for cardiac surgery. The subgroup (n = 24) consisted specifically of patients with a calcific mitral valve. INTERVENTIONS: Preinduction TTE and postinduction TEE in the operating room. MEASUREMENTS AND RESULTS: MAVIR, RVol, and EROA were measured in all patients both by TTE and TEE. Cohen's kappa statistics was employed to quantify concordance among RVol, EROA, and MAVIR. Diagnostic indices of MAVIR toward diagnosis of severe MR also were quantified. The results showed a strong agreement, in differentiating severe from nonsevere MR, between MAVIR and both RVol and EROA in the whole cohort (n = 100) and the subgroup (n = 24), both by TTE and TEE. Diagnostic indices were high for MAVIR compared with RVol and EROA in detecting severe MR, both by TTE and TEE. CONCLUSION: MAVIR may be used as an echocardiographic tool to differentiate between severe and nonsevere MR, even in patients with calcific valves. It also can be used to screen patients for severe MR.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Adulto , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ecocardiografía Doppler en Color/métodos , Estudios Prospectivos , Estudios Transversales , Velocidad del Flujo Sanguíneo , Índice de Severidad de la Enfermedad
2.
Basic Res Cardiol ; 117(1): 29, 2022 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-35643805

RESUMEN

Aortic valve stenosis (AS) is the most frequent valve disease with relevant prognostic impact. Experimental model systems for AS are scarce and comprehensive imaging techniques to simultaneously quantify function and morphology in disease progression are lacking. Therefore, we refined an acute murine AS model to closely mimic human disease characteristics and developed a high-resolution magnetic resonance imaging (MRI) approach for simultaneous in-depth analysis of valvular, myocardial as well as aortic morphology/pathophysiology to identify early changes in tissue texture and critical transition points in the adaptive process to AS. AS was induced by wire injury of the aortic valve. Four weeks after surgery, cine loops, velocity, and relaxometry maps were acquired at 9.4 T to monitor structural/functional alterations in valve, aorta, and left ventricle (LV). In vivo MRI data were subsequently validated by histology and compared to echocardiography. AS mice exhibited impaired valve opening accompanied by significant valve thickening due to fibrotic remodelling. While control mice showed bell-shaped flow profiles, AS resulted not only in higher peak flow velocities, but also in fragmented turbulent flow patterns associated with enhanced circumferential strain and an increase in wall thickness of the aortic root. AS mice presented with a mild hypertrophy but unaffected global LV function. Cardiac MR relaxometry revealed reduced values for both T1 and T2 in AS reflecting subtle myocardial tissue remodelling with early alterations in mitochondrial function in response to the enhanced afterload. Concomitantly, incipient impairments of coronary flow reserve and myocardial tissue integrity get apparent accompanied by early troponin release. With this, we identified a premature transition point with still compensated cardiac function but beginning textural changes. This will allow interventional studies to explore early disease pathophysiology and novel therapeutic targets.


Asunto(s)
Estenosis de la Válvula Aórtica , Imágenes de Resonancia Magnética Multiparamétrica , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Ratones , Función Ventricular Izquierda
3.
Eur Radiol ; 32(12): 8597-8607, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35612663

RESUMEN

OBJECTIVES: 4D flow MRI enables quantitative assessment of helical flow. We sought to generate normal values and elucidate changes of helical flow (duration, volume, length, velocities and rotational direction) and flow jet (displacement, flow angle) as well as wall shear stress (WSS). METHODS: We assessed the temporal helical existence (THEX), maximum helical volume (HVmax), accumulated helical volume (HVacc), accumulated helical volume length (HVLacc), maximum forward velocity (maxVfor), maximum circumferential velocity (maxVcirc), rotational direction (RD) and maximum wall shear stress (WSS) as reported elsewhere using the software tool Bloodline in 86 healthy volunteers (46 females, mean age 41 ± 13 years). RESULTS: WSS decreased by 42.1% and maxVfor by 55.7% across age. There was no link between age and gender regarding the other parameters. CONCLUSION: This study provides age-dependent normal values regarding WSS and maxVfor and age- and gender-independent normal values regarding THEX, HVmax, HVacc, HVLacc, RD and maxVcirc. KEY POINTS: • 4D flow provides numerous new parameters; therefore, normal values are mandatory. • Wall shear stress decreases over age. • Maximum helical forward velocity decreases over age.


Asunto(s)
Aorta , Hemodinámica , Femenino , Humanos , Adulto , Persona de Mediana Edad , Velocidad del Flujo Sanguíneo , Valores de Referencia , Voluntarios Sanos , Estrés Mecánico
4.
J Cardiovasc Magn Reson ; 23(1): 47, 2021 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-33896419

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) sequences are commonly used to obtain a complete description of the function and structure of the heart, provided that accurate measurements are extracted from images. New methods of extraction of information are being developed, among them, deep neural networks are powerful tools that showed the ability to perform fast and accurate segmentation. Iq1n order to reduce the time spent by reading physicians to process data and minimize intra- and inter-observer variability, we propose a fully automatic multi-scan CMR image analysis pipeline. METHODS: Sequence specific U-Net 2D models were trained to perform the segmentation of the left ventricle (LV), right ventricle (RV) and aorta in cine short-axis, late gadolinium enhancement (LGE), native T1 map, post-contrast T1, native T2 map and aortic flow sequences depending on the need. The models were trained and tested on a set of data manually segmented by experts using semi-automatic and manual tools. A set of parameters were computed from the resulting segmentations such as the left ventricular and right ventricular ejection fraction (EF), LGE scar percentage, the mean T1, T1 post, T2 values within the myocardium, and aortic flow. The Dice similarity coefficient, Hausdorff distance, mean surface distance, and Pearson correlation coefficient R were used to assess and compare the results of the U-Net based pipeline with intra-observer variability. Additionally, the pipeline was validated on two clinical studies. RESULTS: The sequence specific U-Net 2D models trained achieved fast (≤ 0.2 s/image on GPU) and precise segmentation over all the targeted region of interest with high Dice scores (= 0.91 for LV, = 0.92 for RV, = 0.93 for Aorta in average) comparable to intra-observer Dice scores (= 0.86 for LV, = 0.87 for RV, = 0.95 for aorta flow in average). The automatically and manually computed parameters were highly correlated (R = 0.91 in average) showing results superior to the intra-observer variability (R = 0.85 in average) for every sequence presented here. CONCLUSION: The proposed pipeline allows for fast and robust analysis of large CMR studies while guaranteeing reproducibility, hence potentially improving patient's diagnosis as well as clinical studies outcome.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Automatización , Estudios de Casos y Controles , Aprendizaje Profundo , Cardiopatías/fisiopatología , Cardiopatías/terapia , Humanos , Miocardio/patología , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Volumen Sistólico , Función Ventricular Izquierda , Función Ventricular Derecha
5.
Echocardiography ; 38(2): 351-353, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33403741

RESUMEN

The reverse flow in the aortic arch in newborn is a rare finding due to congenital heart disease with blood "stealing" from the descending aorta or severe left ventricular outflow tract obstruction and to extracardiac abnormalities as systemic arteriovenous malformation. We describe a female newborn with unexpected reverse flow in the aortic arch due to severe persistent pulmonary hypertension (PPH). The presence of reverse flow in the aortic arch in PPH, secondary to compromised LV output, was rarely reported and investigated but can be a helpful sign of worse clinical course and poor prognosis.


Asunto(s)
Cardiopatías Congénitas , Hipertensión Pulmonar , Aorta Torácica/diagnóstico por imagen , Femenino , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Hipertensión Pulmonar/complicaciones , Recién Nacido
6.
J Exp Biol ; 223(Pt 17)2020 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-32680902

RESUMEN

In the current study we used transthoracic echocardiography to measure stroke volume (SV), heart rate (fH) and cardiac output (CO) in adult bottlenose dolphins (Tursiops truncatus), a male beluga whale calf [Delphinapterus leucas, body mass (Mb) range: 151-175 kg] and an adult female false killer whale (Pseudorca crassidens, estimated Mb: 500-550 kg) housed in managed care. We also recorded continuous electrocardiogram (ECG) in the beluga whale, bottlenose dolphin, false killer whale, killer whale (Orcinus orca) and pilot whale (Globicephala macrorhynchus) to evaluate cardiorespiratory coupling while breathing spontaneously under voluntary control. The results show that cetaceans have a strong respiratory sinus arrythmia (RSA), during which both fH and SV vary within the interbreath interval, making average values dependent on the breathing frequency (fR). The RSA-corrected fH was lower for all cetaceans compared with that of similarly sized terrestrial mammals breathing continuously. As compared with terrestrial mammals, the RSA-corrected SV and CO were either lower or the same for the dolphin and false killer whale, while both were elevated in the beluga whale. When plotting fR against fH for an inactive mammal, cetaceans had a greater cardiac response to changes in fR as compared with terrestrial mammals. We propose that these data indicate an important coupling between respiration and cardiac function that enhances gas exchange, and that this RSA is important to maximize gas exchange during surface intervals, similar to that reported in the elephant seal.


Asunto(s)
Delfín Mular , Cetáceos , Animales , Gasto Cardíaco , Femenino , Masculino , Mamíferos , Volumen Sistólico
7.
Heart Vessels ; 35(12): 1689-1698, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32504319

RESUMEN

Heart failure (HF) with mid-range left ventricular ejection fraction (LVEF) (HFmrEF) is considered a new category of HF and LVEF < 50%, which is the upper threshold of LVEF for HFmrEF, is thought to represent a mild decrease in LV contractile performance. We aimed to consider an LVEF threshold value to be taken as a surrogate for impairment of LV contractile performance, resulting in new-onset HF. We enrolled 398 patients with LVEF ≥ 40% that underwent cardiac catheterization. Using the LV pressure recording with a catheter-tipped micromanometer, we calculated the inertia force of late systolic aortic flow (IFLSAF), which was sensitive to the slight impairment in LV contractile performance. We evaluated the utility of the IFLSAF for predicting future cardiovascular death or hospitalization for HF. We performed a receiver operating characteristic (ROC) curve analysis to determine the best LVEF threshold value for distinguishing whether the LV maintained the IFLSAF. A multivariate Cox proportional-hazards model revealed that the loss of IFLSAF was significantly associated with the future adverse events (HR: 7.798, 95%CI 2.174-27.969, p = 0.002). According to the ROC curve analysis, an LVEF ≥ 58% indicated that the LV could maintain the IFLSAF. We concluded that the loss of IFLSAF, which could reflect even slight impairment in LV contractile performance, was a reliable indicator for new-onset HF in patients with LVEF ≥ 40%. LVEF ≥ 58% could be taken as a surrogate for the IFLSAF maintenance; this threshold could be useful for risk stratification of new-onset HF in patients with preserved LVEF.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia Cardíaca/diagnóstico , Contracción Miocárdica , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico , Función Ventricular Izquierda , Presión Ventricular , Anciano , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Femenino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Transductores de Presión , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia
8.
J Cardiothorac Vasc Anesth ; 34(1): 289-293, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31590940

RESUMEN

The development of echocardiography was driven, in part, by a need to diagnose mitral regurgitation in patients undergoing finger fracture commissurotomy in the 1950s. Decades later, color Doppler became the cornerstone for noninvasive evaluation of mitral regurgitation. The authors present 2 cases of calcific mitral stenosis in which reliance on color Doppler in transthoracic echocardiography resulted in erroneous conclusions as to the severity of coexisting mitral regurgitation. The possible application of the Mitral to Aortic Flow Velocity Integral Ratio in such cases as a possible adjunct to grading mitral regurgitation is also discussed.


Asunto(s)
Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Aorta , Velocidad del Flujo Sanguíneo , Ecocardiografía , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
9.
Cardiol Young ; 30(2): 284-286, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31933446

RESUMEN

Truncus arteriosus is a rare cyanotic congenital heart defect that involves septation failure of the heart's main arterial outflow tract. Varying morphologies of the truncal valve and aorta have been reported; however, the ascending aorta is typically supplied via anterograde blood flow through the truncal valve. We present the first reported case of neonatal truncus arteriosus with the ascending aorta being supplied entirely by retrograde flow.


Asunto(s)
Enfermedad de la Válvula Aórtica/complicaciones , Cardiopatías Congénitas/diagnóstico , Hemodinámica , Tronco Arterial Persistente/complicaciones , Enfermedad de la Válvula Aórtica/fisiopatología , Angiografía por Tomografía Computarizada , Ecocardiografía Doppler en Color , Humanos , Recién Nacido , Masculino , Tronco Arterial Persistente/fisiopatología , Ultrasonografía Prenatal
10.
Pflugers Arch ; 471(7): 935-947, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30904932

RESUMEN

The cardiac pumping mechanics can be characterized by both the maximal systolic elastance (Emax) and theoretical maximum flow (Qmax), which are generated using an elastance-resistance model. The signals required to fit the elastance-resistance model are the simultaneously recorded left ventricular (LV) pressure and aortic flow (Qm), followed by the isovolumic LV pressure. In this study, we evaluated a single-beat estimation technique for determining the Emax and Qmax by using the elastance-resistance model based solely on the measured LV pressure and cardiac output. The isovolumic LV pressure was estimated from the measured LV pressure by using a non-linear least-squares approximation technique. The measured Qm was approximated by an unknown triangular flow (Qtri), which was generated by using a fourth-order derivative of the LV pressure. The Qtri scale was calibrated using the cardiac output. Values of EmaxtriQ and QmaxtriQ obtained using Qtri were compared with those of EmaxmQ and QmaxmQ obtained from the measured Qm. Healthy rats and rats with chronic kidney disease or diabetes mellitus were examined. We found that the LV Emax and Qmax can be approximately calculated using the assumed Qtri, and they strongly correlated with the corresponding values derived from Qm (P < 0.0001; n = 78): EmaxtriQ = 51.9133 + 0.8992 × EmaxmQ (r2 = 0.8257; P < 0.0001); QmaxtriQ = 2.4053 + 0.9767 × QmaxmQ (r2 = 0.7798; P < 0.0001). Our findings suggest that the proposed technique can be a useful tool for determining Emax and Qmax by using a single LV pressure pulse together with cardiac output.


Asunto(s)
Gasto Cardíaco/fisiología , Corazón/fisiología , Función Ventricular/fisiología , Presión Ventricular/fisiología , Animales , Aorta/fisiología , Frecuencia Cardíaca/fisiología , Masculino , Ratas , Ratas Wistar , Sístole/fisiología
11.
J Endovasc Ther ; 26(4): 448-455, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31088321

RESUMEN

Purpose: To analyze the distribution of air bubbles in the supra-aortic vessels during thoracic stent-graft deployment in zones 2 and 3 in an aortic flow model. Materials and Methods: Ten identical, investigational, tubular, thoracic stent-grafts were deployed in a glass aortic flow model with a type I arch: 5 in zone 2 and 5 in zone 3. A pulsatile pump generated a flow of 5 L/min with systolic and diastolic pressures (±5%) of 105 and 70 mm Hg, respectively. The flow rates (±5%) were 300 mL/min in the subclavian arteries, 220 mL/min in the vertebral arteries, and 400 mL/min in the common carotid arteries (CCAs). The total amounts of air released in each supra-aortic branch and in the aorta were recorded. Results: The mean amounts of air measured were 0.82±0.23 mL in the zone-2 group and 0.94±0.28 mL in the zone-3 group (p=0.49). In the zone-2 group compared with zone 3, the amounts of released air were greater in the right subclavian artery (0.07±0.02 vs 0.02±0.02 mL, p<0.01) and right CCA (0.30±0.8 vs 0.18±07 mL, p=0.04). There were no differences between the groups concerning the mean amounts of air measured in the right vertebral and all left-side supra-aortic branches. The amount of air released in the descending aorta was significantly higher in the zone-3 group vs the zone-2 group (0.48±0.12 vs 0.13±0.08 mL, p<0.01). Small bubbles were observed continuously during deployment, whereas large bubbles appeared more commonly during deployment of the proximal stent-graft end and after proximal release of the stent-graft. Conclusion: Air is released into all supra-aortic branches and the descending aorta during deployment of tubular thoracic stent-grafts in zones 2 and 3 in an aortic flow model. Higher amounts of air were observed in right-side supra-aortic branches during deployment in zone 2, whereas significantly greater amounts of air were observed in the descending aorta during deployment in zone 3.


Asunto(s)
Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Embolia Aérea/etiología , Procedimientos Endovasculares/efectos adversos , Flujo Pulsátil , Aorta Torácica/fisiopatología , Velocidad del Flujo Sanguíneo , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Embolia Aérea/fisiopatología , Procedimientos Endovasculares/instrumentación , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis , Factores de Riesgo , Stents , Factores de Tiempo
12.
J Biomech Eng ; 141(10)2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-30840028

RESUMEN

The arterial input function (AIF)-time-density curve (TDC) of contrast at the coronary ostia-plays a central role in contrast enhanced computed tomography angiography (CTA). This study employs computational modeling in a patient-specific aorta to investigate mixing and dispersion of contrast in the aortic arch (AA) and to compare the TDCs in the coronary ostium and the descending aorta. Here, we examine the validity of the use of TDC in the descending aorta as a surrogate for the AIF. Computational fluid dynamics (CFD) was used to study hemodynamics and contrast dispersion in a CTA-based patient model of the aorta. Variations in TDC between the aortic root, through the AA and at the descending aorta and the effect of flow patterns on contrast dispersion was studied via postprocessing of the results. Simulations showed complex unsteady patterns of contrast mixing and dispersion in the AA that are driven by the pulsatile flow. However, despite the relatively long intra-aortic distance between the coronary ostia and the descending aorta, the TDCs at these two locations were similar in terms of rise-time and up-slope, and the time lag between the two TDCs was 0.19 s. TDC in the descending aorta is an accurate analog of the AIF. Methods that use quantitative metrics such as rise-time and slope of the AIF to estimate coronary flowrate and myocardial ischemia can continue with the current practice of using the TDC at the descending aorta as a surrogate for the AIF.

13.
J Surg Res ; 232: 121-127, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30463707

RESUMEN

BACKGROUND: The aim of our study was to describe and validate the use of a bubble counter in an aortic flow model assessing the distribution of air bubbles in the supra-aortic vessel during thoracic stent-graft deployment. MATERIALS AND METHODS: In an aortic flow model made by glass, identical tubular thoracic stent grafts (Zenith TX2 ProForm; Cook Medical, Bjaeverskov, Denmark) were deployed distal to the left subclavian artery. Four steps were defined during deployment: (1) introduction of the stent graft in the arch; (2) deployment of the stent graft; (3) proximal release of the stent graft; and (4) retrieval of the introduction system. On both sides, the common carotid and the vertebral artery were connected together, and the air bubbles were measured with one bubble counter probe per side. The number of air bubbles, as well as their size and distribution, is analyzed during these four steps for the left and right sides with a bubble counter. RESULTS: Ten thoracic stent grafts were included in the study. The total number of air bubbles measured during all steps was significantly higher on the left side (1091 ± 255 versus 545 ± 288, P < 0.00001). During the third step, significantly higher numbers of bubbles were observed on the left side (P = 0.0000001) compared with the right side. The analysis of all bubbles by size revealed that a higher number of bubbles ranged 100-200 µm (P < 0.02) and 200-300 µm (P < 0.03) on the left side. Small bubbles were observed during all steps of deployment, whereas large bubbles appeared more commonly during the second and third steps. CONCLUSIONS: A significant number of air bubbles are released during deployment of tubular thoracic stent grafts distally of the left subclavian artery in an aortic flow model. The distribution of air bubbles is bilateral with a higher number of air bubbles released on the left side.


Asunto(s)
Aorta Torácica/cirugía , Procedimientos Endovasculares/efectos adversos , Stents , Aire , Aorta Torácica/fisiología , Implantación de Prótesis Vascular/efectos adversos , Humanos , Flujo Sanguíneo Regional
14.
BMC Vet Res ; 13(1): 325, 2017 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-29121915

RESUMEN

BACKGROUND: Cardiac output (CO) is an important haemodynamic parameter to monitor in patients during surgery. However, the majority of the techniques for measuring CO have a limited application in veterinary practice due to their invasive approach and associated complexity and risks. Transoesophageal echocardiography (TEE) is a technique used to monitor cardiac function in human patients during surgical procedures and allows CO to be measured non-invasively. This prospective clinical study aimed to compare the transoesophageal echocardiography using a transgastric view of the left ventricular outflow tract (LVOT) and the thermodilution (TD) technique for the assessment of CO during mean arterial pressure of 65-80 mmHg (normotension) and <65 mmHg (hypotension) in dogs undergoing elective surgery. Eight dogs were pre-medicated with acepromazine (0.05 mg/kg, IM), tramadol (4 mg/kg, IM) and atropine (0.03 mg/kg, IM), followed by anaesthetic induction with propofol (3-5 mg/kg IV) and maintenance with isoflurane associated with a continuous infusion rate of fentanyl (bolus of 3 µg/kg followed by 0.3 µg/kg/min). The CO was measured by TEE (COTEE) and TD (COTD) at the end of expiration during normotension and hypotension (induced by isoflurane). RESULTS: There was a strong positive correlation between COTEE and COTD ​​(r = 0.925; P < 0.0001). The bias between COTD and COTEE was 0.14 ± 0.29 L/min (limits of agreement, -0.44 to 0.72 L/min). The percentage error of CO measured by the two methods was 12.32%. In addition, a strong positive correlation was found between COTEE and COTD during normotension (r = 0.995; P < 0.0001) and hypotension (r = 0.78; P = 0.0223). CONCLUSIONS: The results of this study indicated that the transgastric view of the LVOT by TEE was a minimally invasive alternative to clinically monitoring CO in dogs during anaesthesia. However, during hypotension, the CO obtained by TEE was less reliable, although still acceptable.


Asunto(s)
Gasto Cardíaco/fisiología , Perros/fisiología , Ecocardiografía Transesofágica/veterinaria , Termodilución/veterinaria , Anestesia/veterinaria , Animales , Ecocardiografía Transesofágica/métodos , Hipotensión/inducido químicamente , Isoflurano/farmacología , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/veterinaria , Estudios Prospectivos , Reproducibilidad de los Resultados , Termodilución/métodos
15.
Eur Radiol ; 26(5): 1503-11, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26267520

RESUMEN

OBJECTIVES: To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS: Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular (LV) volumes and mass (LVM) using conventional and threshold-based segmentations. Phase-contrast images were used to independently measure stroke volume (SV). LV parameters were evaluated by two independent readers. RESULTS: Evaluation times using the conventional and threshold-based methods were 8.4 ± 1.9 and 4.2 ± 1.3 min, respectively (P < 0.0001). LV parameters measured by the conventional and threshold-based methods, respectively, were end-diastolic volume (EDV) 146 ± 59 and 134 ± 53 ml; end-systolic volume (ESV) 64 ± 47 and 59 ± 46 ml; SV 82 ± 29 and 74 ± 28 ml (flow-based 74 ± 30 ml); ejection fraction (EF) 59 ± 16 and 58 ± 17%; and LVM 141 ± 55 and 159 ± 58 g. Significant differences between the conventional and threshold-based methods were observed in EDV, ESV, and LVM mesurements; SV from threshold-based and flow-based measurements were in agreement (P > 0.05) but were significantly different from conventional analysis (P < 0.05). Excellent inter-observer agreement was observed. CONCLUSIONS: Threshold-based LV segmentation provides improved accuracy and faster assessment compared to conventional contour-based methods. KEY POINTS: • Threshold-based left ventricular segmentation provides time-efficient assessment of left ventricular parameters • The threshold-based method can discriminate between blood and papillary muscles • This method provides improved accuracy compared to aortic flow measurements as a reference.


Asunto(s)
Disfunción Ventricular Izquierda/fisiopatología , Algoritmos , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/patología , Humanos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Miocardio/patología , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/patología
16.
Cardiol Young ; 26(5): 1002-4, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27055647

RESUMEN

In this study, we present the case of a neonate with obstructed infracardiac total anomalous pulmonary venous connection with severe pulmonary hypertension and a patent ductus arteriosus with right-to-left shunting. The patient had an unusual finding of pandiastolic flow reversal in the upper descending thoracic aorta. He underwent emergency surgical re-routing of the pulmonary veins to the left atrium, and postoperative echocardiography showed disappearance of the descending aortic flow reversal. We hypothesise that in severely obstructed total anomalous pulmonary venous connection the left ventricular output may be extremely low, resulting in flow reversal in the descending aorta.


Asunto(s)
Aorta Torácica/fisiopatología , Conducto Arterioso Permeable/diagnóstico por imagen , Hipertensión Pulmonar/etiología , Venas Pulmonares/anomalías , Síndrome de Cimitarra/diagnóstico por imagen , Síndrome de Cimitarra/cirugía , Ecocardiografía , Humanos , Recién Nacido , Masculino
17.
Am J Physiol Heart Circ Physiol ; 309(5): H969-76, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26163442

RESUMEN

Estimation of aortic and left ventricular (LV) pressure usually requires measurements that are difficult to acquire during the imaging required to obtain concurrent LV dimensions essential for determination of LV mechanical properties. We describe a novel method for deriving aortic pressure from the aortic flow velocity. The target pressure waveform is divided into an early systolic upstroke, determined by the water hammer equation, and a diastolic decay equal to that in the peripheral arterial tree, interposed by a late systolic portion described by a second-order polynomial constrained by conditions of continuity and conservation of mean arterial pressure. Pulse wave velocity (PWV, which can be obtained through imaging), mean arterial pressure, diastolic pressure, and diastolic decay are required inputs for the algorithm. The algorithm was tested using 1) pressure data derived theoretically from prespecified flow waveforms and properties of the arterial tree using a single-tube 1-D model of the arterial tree, and 2) experimental data acquired from a pressure/Doppler flow velocity transducer placed in the ascending aorta in 18 patients (mean ± SD: age 63 ± 11 yr, aortic BP 136 ± 23/73 ± 13 mmHg) at the time of cardiac catheterization. For experimental data, PWV was calculated from measured pressures/flows, and mean and diastolic pressures and diastolic decay were taken from measured pressure (i.e., were assumed to be known). Pressure reconstructed from measured flow agreed well with theoretical pressure: mean ± SD root mean square (RMS) error 0.7 ± 0.1 mmHg. Similarly, for experimental data, pressure reconstructed from measured flow agreed well with measured pressure (mean RMS error 2.4 ± 1.0 mmHg). First systolic shoulder and systolic peak pressures were also accurately rendered (mean ± SD difference 1.4 ± 2.0 mmHg for peak systolic pressure). This is the first noninvasive derivation of aortic pressure based on fluid dynamics (flow and wave speed) in the aorta itself.


Asunto(s)
Aorta/fisiología , Velocidad del Flujo Sanguíneo , Presión Sanguínea , Modelos Cardiovasculares , Anciano , Humanos , Persona de Mediana Edad
18.
J Exp Biol ; 218(Pt 22): 3604-10, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26385334

RESUMEN

Heart-rate (fH) changes during diving and exercise are well documented for marine mammals, but changes in stroke volume (SV) and cardiac output (CO) are much less known. We hypothesized that both SV and CO are also modified following intense exercise. Using transthoracic ultrasound Doppler at the level of the aortic valve, we compared blood flow velocities in the left ventricle and cardiac frequencies during rest and at 1, 3 and 4 min after a bout of exercise in 13 adult bottlenose dolphins (Tursiops truncatus, six male and seven female, body mass range 143-212 kg). Aortic cross-sectional area and ventricle blood velocity at the aortic valve were used to calculate SV, which together with fH provided estimates of left CO at rest and following exercise. fH and SV stabilized approximately 4-7 s following the post-respiratory tachycardia, so only data after the fH had stabilized were used for analysis and comparison. There were significant increases in fH, SV and CO associated with each breath. At rest, fH, SV and CO were uncorrelated with body mass, and averaged 41±9 beats min(-1), 136±19 ml and 5514±1182 l min(-1), respectively. One minute following high intensity exercise, the cardiac variables had increased by 104±43%, 63±11% and 234±84%, respectively. All variables remained significantly elevated in all animals for at least 4 min after the exercise. These baseline values provide the first data on SV and CO in awake and unrestrained cetaceans in water.


Asunto(s)
Delfín Mular/fisiología , Gasto Cardíaco , Condicionamiento Físico Animal , Volumen Sistólico , Función Ventricular Izquierda/fisiología , Animales , Ecocardiografía , Femenino , Masculino , Descanso , Sístole
19.
Am J Physiol Heart Circ Physiol ; 306(10): H1408-16, 2014 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-24705557

RESUMEN

The aim of this study is to quantify aortic backward flow (BF) using phase-contrast cardiovascular magnetic resonance (PC-CMR) and to study its associations with age, indexes of arterial stiffness, and geometry. Although PC-CMR blood flow studies showed a simultaneous presence of BF and forward flow (FF) in the ascending aorta (AA), the relationship between aortic flows and aging as well as arterial stiffness and geometry in healthy volunteers has never been reported. We studied 96 healthy subjects [47 women, 39 ± 15 yr old (19-79 yr)]. Aortic stiffness [arch pulse wave velocity (PWVAO), AA distensibility], geometry (AA diameter and arch length), and parameters related to AA BF and FF (volumes, peaks, and onset times) were estimated from CMR. Applanation tonometry carotid-femoral pulse-wave velocity (PWVCF), carotid augmentation index, and time to return of the reflected pressure wave were assessed. Whereas FF parameters remained unchanged, BF onset time shortened significantly (R(2) = 0.18, P < 0.0001) and BF volume and BF-to-FF peaks ratio increased significantly (R(2) = 0.38 and R(2) = 0.44, respectively, P < 0.0001) with aging. These two latter BF indexes were also related to stiffness indexes (PWVCF, R(2) > 0.30; PWVAO, R(2) > 0.24; and distensibility, R(2) > 0.20, P < 0.001), augmentation index (R(2) > 0.20, P < 0.001), and aortic geometry (AA diameter, R(2) > 0.58; and arch length, R(2) > 0.31, P < 0.001). In multivariate analysis, aortic diameter was the strongest independent correlate of BF beyond age effect. In conclusion, AA BF estimated using PC-CMR increased significantly in terms of magnitude and volume and appeared earlier with aging and was mostly determined by aortic geometry. Thus BF indexes could be relevant markers of subclinical arterial wall alterations.


Asunto(s)
Aorta/fisiología , Espectroscopía de Resonancia Magnética , Matemática , Flujo Sanguíneo Regional/fisiología , Adulto , Anciano , Presión Sanguínea/fisiología , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Análisis de la Onda del Pulso , Rigidez Vascular/fisiología