Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Anal Biochem ; 689: 115505, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38460900

RESUMEN

Cardiovascular diseases (CVD) are a range of diseases, pointing the functional hindrances in the heart and blood vessels of the human system that contributes to 48.6 % of the world's adult death rate. The diagnosis of CVD relies upon the Electro Cardio Gram (ECG) and detection of muscle markers such as troponins. Among the cardiac trio, Cardiac Troponin I (cTnI) weighing 23 KiloDalton (kDa) is a sorted biomarker for CVD. cTnI remains high in the blood after 1-2 weeks of myocardial damage. Testing of cTnI in CVD patients aids in diagnosis and risk stratification of the disease. Different determination systems including optical, electrochemical, and acoustic have been put forward for monitoring the cTnI which are Point of Care (POC) that promotes simple and sensitive detection of cTnI. The modern era has paved way to high-sensitivity Troponin I (hscTnI) devices that can detect up to 0.01 ng/ml in human blood/plasma/serum. Yet, the practice of hscTnI is impracticable due to cost inefficiency. Development of new hscTnI devices with minimal investment and maximal detection range will meet the global requirement. This review gives an over view on different detection systems of cardiac troponin I which stands as a translational detection molecule for CVDs.


Asunto(s)
Enfermedades Cardiovasculares , Troponina I , Adulto , Humanos , Troponina T , Relevancia Clínica , Biomarcadores
2.
Sens Actuators B Chem ; 377: 133009, 2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36439054

RESUMEN

Point of care (POC) diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are particularly significant for preventing transmission of coronavirus disease 2019 (COVID-19) by any user at any given time and place. CRISPR/Cas-assisted SARS-CoV-2 assays are viewed as supplemental to RT-PCR due to simple operation, convenient use and low cost. However, most current CRISPR molecular diagnostics based on fluorescence measurement increased the difficulty of POC test with need of the additional light sources. Some instrument-free visual detection with the naked eye has limitations in probe universality. Herein, we developed a universal, rapid, sensitive and specific SARS-CoV-2 POC test that combines the outstanding DNase activity of Cas12a with universal AuNPs strand-displacement probe. The oligo trigger, which is the switch the AuNPs of the strand-displacement probe, is declined as a result of Cas12a recognition and digestion. The amount of released AuNPs produced color change which can be visual with the naked eye and assessed by UV-Vis spectrometer for quantitative detection. Furthermore, a low-cost hand warmer is used as an incubator for the visual assay, enabling an instrument-free, visual SARS-CoV-2 detection within 20 min. A real coronavirus GX/P2V instead of SARS-CoV-2 were chosen for practical application validation. After rapid virus RNA extraction and RT-PCR amplification, a minimum of 2.7 × 102 copies/mL was obtained successfully. The modular design can be applied to many nucleic acid detection applications, such as viruses, bacteria, species, etc., by simply modifying the crRNA, showing great potential in POC diagnosis.

3.
Anal Bioanal Chem ; 413(18): 4625-4634, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33661349

RESUMEN

Herein we report a quantitative, multiplex assay for disease markers in plasma based on an integrated setup of a portable scanner and a disposable paper-based analytical device (PAD). The quantitative analysis relies on the digital colorimetric reading of the three-layer PAD with 30 assay sites for performing respective chromogenic reactions for plasma uric acid, glucose, and triglyceride, which are considered as important risk factors for cardiovascular diseases. A portable scanner with WiFi transmission capability was used to produce high-quality color images of the PADs and wirelessly transfer them to a smartphone or other mobile devices for data processing. The concentrations of biomarkers in both standard solutions and plasma samples can be directly obtained using a custom-designed smartphone app that is also capable of constructing calibration curves. The detection limits of uric acid, glucose, and triglyceride were determined to be 0.50 mg/dL, 0.84 mmol/L, and 14 mg/dL, respectively, which are below the normal limits and adequate for clinical validation. Owing to the distinct advantages-simple, portable, and cost-effective-this mobile assay protocol can be used for point-of-care (POC) settings or resource-limited situations, and potentially for the diagnosis and prevention of infectious diseases.


Asunto(s)
Glucemia/análisis , Internet , Papel , Triglicéridos/sangre , Ácido Úrico/sangre , Biomarcadores/sangre , Colorimetría/instrumentación , Humanos , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Factores de Riesgo , Teléfono Inteligente , Tecnología Inalámbrica
4.
Biomed Microdevices ; 22(2): 39, 2020 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-32436002

RESUMEN

Currently, most HIV tests are performed with blood samples, or alternatively saliva samples are used for HIV testing. Simple HIV tests need to be performed in hospitals or other medical agencies instead of more invasive HIV blood tests. To enable point-of-care (POC) HIV diagnostics, based on a recently developed lateral flow strip for HIV urine testing, a microfluidic immunoassay cassette with a handheld optical reader is developed. Based on lateral flow strip with gold colloid reporter, the integrated immunoassay cassette can perform sample introduction, metering, discharging, applying and detection which simplifies HIV testing. An indicator is incorporated into the cassette to guide sample introduction based on color change, and further, the excess test sample is stored inside the sealed cassette to avoid any contamination. The low-cost handheld optical reader can provide a test result within a few seconds, which is useful for simple, sensitive and affordable HIV onsite detection. Instead of using normal white LEDs, a customized back light module embedded with green LEDs is adopted to illuminate the lateral flow strip with an appropriate working current to achieve optimal performance. Compared to the standard lateral flow strips using a benchtop reader, with the disposable immunoassay cassette assisted by the handheld optical reader, more convenient, easier-to-operate, and more affordable HIV urine testing can be achieved in POC diagnostics.


Asunto(s)
Infecciones por VIH/orina , Inmunoensayo/instrumentación , Pruebas en el Punto de Atención , Urinálisis/instrumentación , Costos y Análisis de Costo , Infecciones por VIH/diagnóstico , Humanos , Inmunoensayo/economía , Urinálisis/clasificación , Urinálisis/economía
5.
Adv Mater ; : e2311931, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39086075

RESUMEN

Polymerase chain reaction (PCR) is the gold standard for nucleic acid amplification and quantification in diverse fields such as life sciences, global health, medicine, agricultural science, forensic science, and environmental science for global sustainability. However, implementing a cost-effective PCR remains challenging for rapid preventive medical action to the widespread pandemic diseases due to the absence of highly efficient and low-cost PCR chip-based POC molecular diagnostics. Here, this work reports an ultrafast metaphotonic PCR chip as a solution of a cost-effective and low-power-consumption POC device for the emerging global challenge of sustainable healthcare. This work designs a near-perfect photonic meta-absorber using ring-shaped titanium nitride to maximize the photothermal effect and realize rapid heating and cooling cycles during the PCR process. This work fabricates a large-area photonic meta-absorber on a 6-inch wafer cost-effectively using simple colloidal lithography. In addition, this work demonstrates 30 thermocycles from 65 (annealing temperature) to 95 °C (denaturation temperature) within 3 min 15 s, achieving an average 16.66 °C s-1 heating rate and 7.77 °C s-1 cooling rate during thermocycling, succeeding rapid metaphotonic PCR. This work believes a metaphotonic PCR chip can be used to create a low-cost, ultrafast molecular diagnostic chip with a meta-absorber.

6.
ACS Sens ; 8(12): 4442-4467, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38091479

RESUMEN

In recent years, there has been a notable increase in interest surrounding nanozymes due to their ability to imitate the functions and address the limitations of natural enzymes. The scientific community has been greatly intrigued by the study of nanoceria, primarily because of their distinctive physicochemical characteristics, which include a variety of enzyme-like activities, affordability, exceptional stability, and the ability to easily modify their surfaces. Consequently, nanoceria have found extensive use in various biosensing applications. However, the impact of its redox activity on the enzymatic catalytic mechanism remains a subject of debate, as conflicting findings in the literature have presented both pro-oxidant and antioxidant effects. Herein, we creatively propose a seesaw model to clarify the regulatory mechanism on redox balance and survey possible mechanisms of multienzyme mimetic properties of nanoceria. In addition, this review aims to showcase the latest advancements in this field by systematically discussing over 180 research articles elucidating the significance of ceria-based nanozymes in enhancing, downsizing, and enhancing the efficacy of point-of-care (POC) diagnostics. These advancements align with the ASSURED criteria established by the World Health Organization (WHO). Furthermore, this review also examines potential constraints in order to offer readers a concise overview of the emerging role of nanoceria in the advancement of POC diagnostic systems for future biosensing applications.


Asunto(s)
Cerio , Sistemas de Atención de Punto , Oxidación-Reducción , Cerio/química , Antioxidantes
7.
Front Cell Infect Microbiol ; 12: 920447, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35873173

RESUMEN

The rapid spread of antimicrobial resistant Neisseria gonorrhoeae continues to pose a serious threat to global health. To successfully treat and control gonococcal infections, rapid diagnosis is critical. Currently, nucleic acid amplification tests are the recommended diagnostic, however, these are both technically demanding and time consuming, making them unsuitable for resource-poor clinics. Consequently, there is a substantial need for an affordable, point-of-care diagnostic to use in these settings. In this study, DNA-functionalised gold nanoparticles (gold nanoprobes), with the ability to specifically detect the DNA Uptake Sequence (DUS) of Neisseria gonorrhoeae, were prepared. Using complementary annealing, the gold nanoprobes were shown to hybridise to genomic gonococcal DNA, causing a significant shift in their salt stability. By exploiting the shift in nanoprobe stability under the presence of target DNA, a solution-based colorimetric diagnostic for gonococcal DNA was prepared. Detection of purified genomic DNA was achieved in under 30 minutes, with a detection limit of 15.0 ng. Significantly, testing with DNA extracted from an off-target control organism suggested specificity for Neisseria. These results highlight the potential of DUS-specific gold nanoprobes in the rapid point-of-care diagnosis of gonococcal infections.


Asunto(s)
Gonorrea , Nanopartículas del Metal , Antibacterianos/farmacología , ADN , Farmacorresistencia Bacteriana , Genómica , Oro , Gonorrea/diagnóstico , Humanos , Pruebas de Sensibilidad Microbiana , Neisseria gonorrhoeae/genética
8.
Front Med (Lausanne) ; 8: 639208, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34722554

RESUMEN

Sickle cell disease is a major public health problem in India. Lack of rapid and reliable diagnostic methods result in many avoidable deaths in affected population. Current diagnostic tools are laboratory based, expensive and need trained manpower. Here, we evaluated the performance of a microchip-based cellulose acetate electrophoresis test, "Gazelle" in the tribal-dominated Indian states of Chhattisgarh and Madhya Pradesh. A total of 1,050 patients were screened by sickle cell solubility, hemoglobin (cellulose acetate) electrophoresis, high-performance liquid chromatography (HPLC) and Gazelle. Of the total 1,027 test results obtained, 960 tests were "Valid" (93.5%) and included in the analysis. Gazelle identified all patients with disease (HbSS and Thalassemia Major) with 100% accuracy. Gazelle demonstrated 100% sensitivity when comparing sickle cell disease (SCD) vs. sickle cell trait and SCD vs. normal. Specificity was 98.9% and 99.5% when comparing SCD vs. trait and trait vs. normal, respectively. Specificity was 99.8% when comparing SCD vs. normal and sensitivity was 99.3% when comparing trait vs. normal. Overall, Gazelle yielded a high accuracy (99.0%) compared to reference standard tests (hemoglobin electrophoresis and HPLC). Gazelle is a low-cost, rapid diagnostic test with high accuracy for detecting SCD both quantitatively and qualitatively. Gazelle can be a potential screening tool for the rapid diagnosis in resource limited settings and developing countries with high burden of hemoglobin disorders.

9.
Front Public Health ; 9: 722943, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34746078

RESUMEN

Background: Point of care testing (POCT) for infectious diseases is testing conducted near the patient. It allows clinicians to offer the most appropriate treatment more quickly. As POCT devices have increased in accuracy and become more cost-effective, their use has grown, but a systematic assessment of their use for clinical and public health management of infectious diseases in EU/EEA countries has not been previously undertaken. Methods: A scoping review of the literature on POCT in EU/ EEA countries as at November 2019, and a survey of key stakeholders. Results: 350 relevant articles were identified and 54 survey responses from 26 EU/EEA countries were analysed. POCT is available for a range of infectious diseases and in all countries responding to the survey (for at least one disease). POCT is commonly available for influenza, HIV/AIDS, Legionnaires' disease and malaria, where it is used in at least half of EU/EEA countries. While POCT has the potential to support many improvements to clinical care of infectious diseases (e.g., faster diagnosis, more appropriate use of antimicrobials), the results suggest POCT is infrequently used to support public health functions (e.g., disease surveillance and reporting). Conclusion: Although POCT is in use to some extent in all EU/EEA countries, the full benefits of POCT in wider public health functions have yet to be realised. Further research on barriers and facilitators to implementation is warranted.


Asunto(s)
Enfermedades Transmisibles , Gripe Humana , Malaria , Enfermedades Transmisibles/diagnóstico , Europa (Continente) , Humanos , Malaria/diagnóstico , Pruebas en el Punto de Atención
10.
ACS Sens ; 2(11): 1627-1636, 2017 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-28994578

RESUMEN

Gold nanoparticle (GNP)-based aggregation assay is simple, fast, and employs a colorimetric detection method. Although previous studies have reported using GNP-based colorimetric assay to detect biological and chemical targets, a mechanistic and quantitative understanding of the assay and effects of GNP parameters on the assay performance is lacking. In this work, we investigated this important aspect of the GNP aggregation assay including effects of GNP concentration and size on the assay performance to detect malarial DNA. Our findings lead us to propose three major competing factors that determine the final assay performance including the nanoparticle aggregation rate, plasmonic coupling strength, and background signal. First, increasing nanoparticle size reduces the Brownian motion and thus aggregation rate, but significantly increases plasmonic coupling strength. We found that larger GNP leads to stronger signal and improved limit of detection (LOD), suggesting a dominating effect of plasmonic coupling strength. Second, higher nanoparticle concentration increases the probability of nanoparticle interactions and thus aggregation rate, but also increases the background extinction signal. We observed that higher GNP concentration leads to stronger signal at high target concentrations due to higher aggregation rate. However, the fact the optimal LOD was found at intermediate GNP concentrations suggests a balance of two competing mechanisms between aggregation rate and signal/background ratio. In summary, our work provides new guidelines to design GNP aggregation-based POC devices to meet the signal and sensitivity needs for infectious disease diagnosis and other applications.


Asunto(s)
Colorimetría/métodos , Oro/química , Nanopartículas del Metal/química , Oligonucleótidos/análisis , Tamaño de la Partícula , Técnicas Biosensibles , Límite de Detección , Oligonucleótidos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA