Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.982
Filtrar
Más filtros

Colección BVS Ecuador
Intervalo de año de publicación
1.
Circulation ; 149(1): e1-e156, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38033089

RESUMEN

AIM: The "2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation" provides recommendations to guide clinicians in the treatment of patients with atrial fibrillation. METHODS: A comprehensive literature search was conducted from May 12, 2022, to November 3, 2022, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, the Agency for Healthcare Research and Quality, and other selected databases relevant to this guideline. Additional relevant studies, published through November 2022, during the guideline writing process, were also considered by the writing committee and added to the evidence tables, where appropriate. STRUCTURE: Atrial fibrillation is the most sustained common arrhythmia, and its incidence and prevalence are increasing in the United States and globally. Recommendations from the "2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" and the "2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" have been updated with new evidence to guide clinicians. In addition, new recommendations addressing atrial fibrillation and thromboembolic risk assessment, anticoagulation, left atrial appendage occlusion, atrial fibrillation catheter or surgical ablation, and risk factor modification and atrial fibrillation prevention have been developed.


Asunto(s)
Fibrilación Atrial , Cardiología , Tromboembolia , Humanos , American Heart Association , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Factores de Riesgo , Estados Unidos/epidemiología
2.
Eur Heart J ; 45(1): 32-41, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37453044

RESUMEN

AIMS: Transoesophageal echocardiography (TOE) is often performed before catheter ablation or cardioversion to rule out the presence of left atrial appendage thrombus (LAT) in patients on chronic oral anticoagulation (OAC), despite associated discomfort. A machine learning model [LAT-artificial intelligence (AI)] was developed to predict the presence of LAT based on clinical and transthoracic echocardiography (TTE) features. METHODS AND RESULTS: Data from a 13-site prospective registry of patients who underwent TOE before cardioversion or catheter ablation were used. LAT-AI was trained to predict LAT using data from 12 sites (n = 2827) and tested externally in patients on chronic OAC from two sites (n = 1284). Areas under the receiver operating characteristic curve (AUC) of LAT-AI were compared with that of left ventricular ejection fraction (LVEF) and CHA2DS2-VASc score. A decision threshold allowing for a 99% negative predictive value was defined in the development cohort. A protocol where TOE in patients on chronic OAC is performed depending on the LAT-AI score was validated in the external cohort. In the external testing cohort, LAT was found in 5.5% of patients. LAT-AI achieved an AUC of 0.85 [95% confidence interval (CI): 0.82-0.89], outperforming LVEF (0.81, 95% CI 0.76-0.86, P < .0001) and CHA2DS2-VASc score (0.69, 95% CI: 0.63-0.7, P < .0001) in the entire external cohort. Based on the proposed protocol, 40% of patients on chronic OAC from the external cohort would safely avoid TOE. CONCLUSION: LAT-AI allows accurate prediction of LAT. A LAT-AI-based protocol could be used to guide the decision to perform TOE despite chronic OAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cardiopatías , Trombosis , Humanos , Ecocardiografía Transesofágica/métodos , Apéndice Atrial/diagnóstico por imagen , Volumen Sistólico , Inteligencia Artificial , Fibrilación Atrial/complicaciones , Función Ventricular Izquierda , Ecocardiografía , Cardiopatías/diagnóstico , Trombosis/diagnóstico , Factores de Riesgo
3.
Eur Heart J ; 45(3): 214-229, 2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-38088437

RESUMEN

BACKGROUND AND AIMS: Residual leaks are not infrequent after left atrial appendage occlusion. However, there is still uncertainty regarding their prognostic implications. The aim of this study is to evaluate the impact of residual leaks after left atrial appendage occlusion. METHODS: A literature search was conducted until 19 February 2023. Residual leaks comprised peri-device leaks (PDLs) on transoesophageal echocardiography (TEE) or computed tomography (CT), as well as left atrial appendage patency on CT. Random-effects meta-analyses were performed to assess the clinical impact of residual leaks. RESULTS: Overall 48 eligible studies (44 non-randomized/observational and 4 randomized studies) including 61 666 patients with atrial fibrillation who underwent left atrial appendage occlusion were analysed. Peri-device leak by TEE was present in 26.1% of patients. Computed tomography-based left atrial appendage patency and PDL were present in 54.9% and 57.3% of patients, respectively. Transoesophageal echocardiography-based PDL (i.e. any reported PDL regardless of its size) was significantly associated with a higher risk of thromboembolism [pooled odds ratio (pOR) 2.04, 95% confidence interval (CI): 1.52-2.74], all-cause mortality (pOR 1.16, 95% CI: 1.08-1.24), and major bleeding (pOR 1.12, 95% CI: 1.03-1.22), compared with no reported PDL. A positive graded association between PDL size and risk of thromboembolism was noted across TEE cut-offs. For any PDL of >0, >1, >3, and >5 mm, the pORs for thromboembolism were 1.82 (95% CI: 1.35-2.47), 2.13 (95% CI: 1.04-4.35), 4.14 (95% CI: 2.07-8.27), and 4.44 (95% CI: 2.09-9.43), respectively, compared with either no PDL or PDL smaller than each cut-off. Neither left atrial appendage patency, nor PDL by CT was associated with thromboembolism (pOR 1.45 and 1.04, 95% CI: 0.84-2.50 and 0.52-2.07, respectively). CONCLUSIONS: Peri-device leak detected by TEE was associated with adverse events, primarily thromboembolism. Residual leaks detected by CT were more frequent but lacked prognostic significance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Tromboembolia , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Tromboembolia/complicaciones , Ecocardiografía Transesofágica/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía
4.
Eur Heart J ; 45(32): 2914-2932, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39027946

RESUMEN

Atrial fibrillation (AF) is associated with an increased risk of stroke and systemic embolism, and the left atrial appendage (LAA) has been identified as a principal source of thromboembolism in these patients. While oral anticoagulation is the current standard of care, LAA closure (LAAC) emerges as an alternative or complementary treatment approach to reduce the risk of stroke or systemic embolism in patients with AF. Moderate-sized randomized clinical studies have provided data for the efficacy and safety of catheter-based LAAC, largely compared with vitamin K antagonists. LAA device iterations, advances in pre- and peri-procedural imaging, and implantation techniques continue to increase the efficacy and safety of LAAC. More data about efficacy and safety of LAAC have been collected, and several randomized clinical trials are currently underway to compare LAAC with best medical care (including non-vitamin K antagonist oral anticoagulants) in different clinical settings. Surgical LAAC in patients with AF undergoing cardiac surgery reduced the risk of stroke on background of anticoagulation therapy in the LAAOS III study. In this review, we describe the rapidly evolving field of LAAC and discuss recent clinical data, ongoing studies, open questions, and current limitations of LAAC.


Asunto(s)
Anticoagulantes , Fibrilación Atrial , Cierre del Apéndice Auricular Izquierdo , Accidente Cerebrovascular , Humanos , Anticoagulantes/uso terapéutico , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Cierre del Apéndice Auricular Izquierdo/instrumentación , Ensayos Clínicos Controlados Aleatorios como Asunto , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/etiología
5.
Circulation ; 148(17): 1298-1304, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37732457

RESUMEN

BACKGROUND: LAAOS III (Left Atrial Appendage Occlusion Study III) showed that left atrial appendage (LAA) occlusion reduces the risk of ischemic stroke or systemic embolism in patients with atrial fibrillation undergoing cardiac surgery. This article examines the effect of LAA occlusion on stroke reduction according to variation in the use of oral anticoagulant (OAC) therapy. METHODS: Information regarding OAC use was collected at every follow-up visit. Adjusted proportional hazards modeling, including using landmarks of hospital discharge, 1 and 2 years after randomization, evaluated the effect of LAA occlusion on the risk of ischemic stroke or systemic embolism, according to OAC use. Adjusted proportional hazard modeling, with OAC use as a time-dependent covariate, was also performed to assess the effect of LAA occlusion, according to OAC use throughout the study. RESULTS: At hospital discharge, 3027 patients (63.5%) were receiving a vitamin K antagonist, and 879 (18.5%) were receiving a non-vitamin K antagonist oral anticoagulant (direct OAC), with no difference in OAC use between treatment arms. There were 2887 (60.5%) patients who received OACs at all follow-up visits, 1401 (29.4%) who received OAC at some visits, and 472 (9.9%) who never received OACs. The effect of LAA occlusion on the risk of ischemic stroke or systemic embolism was consistent after discharge across all 3 groups: hazard ratios of 0.70 (95% CI, 0.51-0.96), 0.63 (95% CI, 0.43-0.94), and 0.76 (95% CI, 0.32-1.79), respectively. An adjusted proportional hazards model with OAC use as a time-dependent covariate showed that the reduction in stroke or systemic embolism with LAA occlusion was similar whether patients were receiving OACs or not. CONCLUSIONS: The benefit of LAA occlusion was consistent whether patients were receiving OACs or not. LAA occlusion provides thromboembolism reduction in patients independent of OAC use.

6.
Stroke ; 55(1): 205-213, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38134250

RESUMEN

Atrial fibrillation is a major cause of ischemic stroke. Technological advances now support prolonged cardiac rhythm monitoring using either surface electrodes or insertable cardiac monitors. Four major randomized controlled trials show that prolonged cardiac monitoring detects subclinical paroxysmal atrial fibrillation in 9% to 16% of patients with ischemic stroke, including in patients with potential alternative causes such as large artery disease or small vessel occlusion; however, the optimal monitoring strategy, including the target patient population and the monitoring device (whether to use an event monitor, insertable cardiac monitor, or stepped approach) has not been well defined. Furthermore, the clinical significance of very short duration paroxysmal atrial fibrillation remains controversial. The relevance of the duration of monitoring, burden of device-detected atrial fibrillation, and its proximity to the acute ischemic stroke will require more research to define the most effective methods for stroke prevention in this patient population.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Accidente Cerebrovascular Isquémico/tratamiento farmacológico , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Factores de Riesgo , Monitoreo Fisiológico/métodos , Anticoagulantes/uso terapéutico
7.
Stroke ; 55(1): 214-225, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38134262

RESUMEN

Nonvalvular atrial fibrillation is a common rhythm disorder of middle-aged to older adults that can cause ischemic strokes and systemic embolism. Lifelong use of oral anticoagulants reduces the risk of these ischemic events but increases the risk of major and clinically relevant hemorrhages. These medications also require strict compliance for efficacy, and they have nontrivial failure rates in higher-risk patients. Left atrial appendage closure is a nonpharmacological method to prevent ischemic strokes in atrial fibrillation without the need for lifelong anticoagulant use, but this procedure has the potential for complications and residual embolic events. This workshop of the Roundtable of Academia and Industry for Stroke Prevention discussed future research needed to further decrease the ischemic and hemorrhagic risks among patients with atrial fibrillation. A direct thrombin inhibitor, factor Xa inhibitors, and left atrial appendage closure are FDA-approved approaches whereas factor XIa inhibitors are currently being studied in phase 3 randomized controlled trials for stroke prevention. The benefits, risks, and shortcomings of these treatments and future research required in different high-risk patient populations are reviewed in this consensus statement.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Persona de Mediana Edad , Humanos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Anticoagulantes/uso terapéutico , Embolia/complicaciones , Accidente Cerebrovascular Isquémico/tratamiento farmacológico , Resultado del Tratamiento
8.
J Transl Med ; 22(1): 734, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103891

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is associated with increased risk of stroke and mortality. It has been reported that the process of atrial fibrosis was regulated by ß-catenin in rats with AF. However, pathophysiological mechanisms of this process in human with AF remain unclear. This study aims to investigate the possible mechanisms of ß-catenin in participating in the atrial fibrosis using human right atrial appendage (hRAA) tissues . METHODS: We compared the difference of ß-catenin expression in hRAA tissues between the patients with AF and sinus rhythm (SR). The possible function of ß-catenin in the development of AF was also explored in mice and primary cells. RESULTS: Firstly, the space between the membrane of the gap junctions of cardiomyocytes was wider in the AF group. Secondly, the expression of the gap junction function related proteins, Connexin40 and Connexin43, was decreased, while the expression of ß-catenin and its binding partner E-cadherin was increased in hRAA and cardiomyocytes of the AF group. Thirdly, ß-catenin colocalized with E-cadherin on the plasma membrane of cardiomyocytes in the SR group, while they were dissociated and accumulated intracellularly in the AF group. Furthermore, the expression of glycogen synthase kinase 3ß (GSK-3ß) and Adenomatous Polyposis Coli (APC), which participated in the degradation of ß-catenin, was decreased in hRAA tissues and cardiomyocytes of the AF group. Finally, the development of atrial fibrosis and AF were proved to be prevented after inhibiting ß-catenin expression in the AF model mice. CONCLUSIONS: Based on human atrial pathological and molecular analyses, our findings provided evidence that ß-catenin was associated with atrial fibrosis and AF progression.


Asunto(s)
Fibrilación Atrial , Fibrosis , Atrios Cardíacos , Miocitos Cardíacos , beta Catenina , Anciano , Animales , Femenino , Humanos , Masculino , Ratones , Persona de Mediana Edad , Fibrilación Atrial/patología , Fibrilación Atrial/metabolismo , beta Catenina/metabolismo , Cadherinas/metabolismo , Conexina 43/metabolismo , Uniones Comunicantes/metabolismo , Glucógeno Sintasa Quinasa 3 beta/metabolismo , Atrios Cardíacos/metabolismo , Atrios Cardíacos/patología , Ratones Endogámicos C57BL , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/patología
9.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38468182

RESUMEN

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Anciano , Humanos , Masculino , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Vasos Coronarios/diagnóstico por imagen , Cierre del Apéndice Auricular Izquierdo , Diseño de Prótesis , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología
10.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37927196

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Resultado del Tratamiento
11.
J Cardiovasc Electrophysiol ; 35(10): 2058-2061, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39121462

RESUMEN

INTRODUCTION: The Centers for Medicare & Medicaid Services (CMS) required a shared decision-making (SDM) interaction, with an "independent" physician, before left atrial appendage closure (LAAC). The purpose of this study is to better understand how this requirement is implemented in clinical practice. METHODS: We surveyed LAAC-performing centers. The characteristics of respondent and nonrespondent hospitals were compared using the CMS Provider of Services File for 2017. RESULTS: We received 86 responses out of 269 surveys mailed (32%). Respondent and nonrespondent hospital affiliations were similar: mean hospital size 525 beds, 15% for-profit, and 34% teaching hospitals. Thirty-four respondents (39.5%) stated that the implanting physician conducts some or all of the SDM interactions. The percentage of patients who decide not to undergo LAAC after the SDM interaction was estimated at 8.1%. Out of 72 responses to an open-ended question about the benefit of the SDM interaction, 44 (61%) described the requirement in negative terms, of which most felt the requirement was burdensome for patients and providers. Only 28 respondents (39%) described the requirement in positive or mixed terms. CONCLUSION: In violation of the letter of the CMS policy for LAAC, implanting physicians perform the SDM interaction at nearly 40% of responding hospitals. Most respondents felt the SDM requirement was burdensome for patients. More detailed guidance from CMS on how to comply with the policy may result in better alignment between the intent of the policy and how it is implemented.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Toma de Decisiones Clínicas , Toma de Decisiones Conjunta , Humanos , Apéndice Atrial/cirugía , Apéndice Atrial/fisiopatología , Estados Unidos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Medicare , Encuestas de Atención de la Salud , Participación del Paciente , Pautas de la Práctica en Medicina , Centers for Medicare and Medicaid Services, U.S. , Procedimientos Quirúrgicos Cardíacos , Resultado del Tratamiento , Cierre del Apéndice Auricular Izquierdo
12.
Artículo en Inglés | MEDLINE | ID: mdl-39407419

RESUMEN

INTRODUCTION: Real-world studies comparing safety and efficacy of combined percutaneous left atrial appendage occlusion (LAAO) and catheter ablation (CA) to LAAO alone are limited. METHODS: Patients from a large US hospital system undergoing combined LAAO and left-atrial CA from 8/2020 to 2/2024 were retrospectively analyzed and compared to a control group undergoing LAAO alone. Controls were identified using a 1:2 propensity score match based on LAAO device type (Watchman FLX vs. Amulet), CHA2D2-VASc and Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile international normalized ratio [INR], Elderly, Drugs/alcohol (HAS-BLED) scores and compared for safety, sealing performance and clinical outcomes at 6 months. RESULTS: Patients were younger in the combined (n = 72) than in the control group (n = 144, 70.2 ± 7.3 vs. 76.7 ± 6.9 years, p < 0.001) but otherwise comparable with a mean CHA2D2-VASc score of 4.2 ± 1.1 and 4.4 ± 1.2 (p = 0.26) and HAS-BLED score of 2.2 ± 0.8 and 2.3 ± 0.7 (p = 0.34). Successful LAAO implantation rates were the same (95.8% vs. 95.8%, p = 0.99) with longer procedure times seen in the combined group (156.5 ± 53 vs. 56 ± 26 min, p < 0.001). Both major (1.4% vs. 2.1%, p = 0.72) and minor (27.8% vs. 19.4%, p = 0.17) in-hospital complications were similar between the combined and control group, respectively. At 45 days, presence of peri-device leak (18.3% vs. 30.4%, p = 0.07) and device related thrombosis (4.5% vs. 4.5%, p = 0.96) on transesophageal echocardiogram did not differ. Finally, all-cause mortality (0% vs. 1.4%, p = 0.99), thromboembolic (0% vs. 0%, p = 0.99) and bleeding (6.1% vs. 4.4%, p = 0.73) events during follow-up were comparable. CONCLUSION: This large, real-world analysis indicates comparable safety and efficiency of combined LAAO and CA when compared with LAAO alone.

13.
J Cardiovasc Electrophysiol ; 35(8): 1601-1613, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38887842

RESUMEN

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.


Asunto(s)
Apéndice Atrial , Ecocardiografía Tetradimensional , Ecocardiografía Transesofágica , Flujo de Trabajo , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Valor Predictivo de las Pruebas , Cateterismo Cardíaco/instrumentación , Ultrasonografía Intervencional , Masculino
14.
Artículo en Inglés | MEDLINE | ID: mdl-39319519

RESUMEN

INTRODUCTION: Left atrial appendage occlusion (LAAO) can be performed using diverse anesthetic approaches ranging from moderate sedation (MS) to general anesthesia (GA), and guided by intracardiac echocardiography (ICE) or transesophageal echocardiography (TEE). Prior studies have demonstrated shorter time in lab for heart rhythm procedures performed under MS. The objective of this study was to compare laboratory times, acute procedural outcomes and complication rates for LAAO procedures performed using MS and 4-dimensional ICE as opposed to GA. METHODS AND RESULTS: This was a retrospective observational cohort study of 135 consecutive patients who were referred for LAAO to be performed with either GA or MS between June 2022 and April 2024. The primary endpoints were total laboratory time, procedure time, nonprocedure time, and fluoroscopy time. The secondary endpoints were stroke, peri-device leak (>5 mm), device-related left atrial thrombus, cardiovascular mortality, and all-cause mortality at 45 days and 6 months postprocedure, where data were available. The mean age of patients in the study was 78.8 ± 7.8 years and 64.4% were male with no difference between GA and MS. In the MS group, 4D-ICE was used for intraprocedural imaging in 95.5% of patients and 2 dimensional-ICE (2D-ICE) was used in 4.5% of patients. In the GA group, intra-procedural imaging was done using TEE in 51.5%, 2D-ICE in 32.4% and 4D-ICE in 16.2% of cases. Total laboratory time was significantly lower in the MS group compared to the GA group (68.3 ± 23.1 vs 117.1 ± 34.3 min; p < 0.001), due to shorter nonprocedure time (15.2 ± 9.1 vs 63.7 ± 22.0 min; p < 0.001), with no significant difference in procedure time and fluoroscopy time. There was no significant difference in complications at 45 days and 6 months postprocedure. CONCLUSION: In this single center study, MS reduced total lab time by reducing nonprocedure time when compared to GA for LAAO, without affecting clinical outcomes.

15.
J Cardiovasc Electrophysiol ; 35(3): 389-398, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38192059

RESUMEN

INTRODUCTION: This study was performed to explore the diagnostic value of cardiac computed tomography angiography (CCTA) for endothelial insufficiency (EIS) of a left atrial appendage (LAA) disc-like occluder. METHODS: Fifty-nine patients with nonvalvular atrial fibrillation who underwent placement of an LAA disc-like occluder (LAmbre; Lifetech Scientific) in our hospital were retrospectively analyzed. Patients who were found to have contrast agent entering the LAA at the 3-month postoperative CCTA examination underwent Hounsfield unit (HU) measurement of the LAA and construction of a three-dimensional (3D) model of the device for preliminary discernment between peri-device leakage (PDL) and EIS. These patients were then further examined by transesophageal echocardiography (TEE) to check for concordance with the computed tomography (CT) findings. According to the CT and TEE results, all patients were divided into the PDL group, total endothelialization group, and EIS group. The endothelial conditions and other implantation-related results were also tracked at the 6-month follow-up. RESULTS: All 59 patients underwent successful implantation of the LAmbre LAA closure device with no severe adverse events during the procedure. Thirty-five patients were found to have contrast agent entering the LAA at the 3-month postoperative CCTA follow-up. Based on the CT HU measurement and the 3D construction analysis results, these 35 patients were divided into the PDL group (19 patients) and the EIS group (16 patients). In the PDL group, the contrast agent infiltrated from the shoulder along the periphery of the occluder on two-dimensional (2D) CT images, and the 3D model showed a gap between the LAA and the device cover. However, the CCTA images of the other 16 patients in the EIS group showed that the contrast agent in the occluder on the 2D CTA images and 3D construction model confirmed the absence of a gap between the LAA and the device cover. TEE confirmed all of the CT results. The 6-month follow-up results showed that 14 of 19 patients in the EIS group achieved total endothelialization, whereas this number in the PDL group was only five of 19 patients. CONCLUSION: CCTA can replace TEE for examination of the endothelialization status, and patients with EIS have a higher chance of endothelialization than patients with PDL.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Angiografía por Tomografía Computarizada/métodos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Retrospectivos , Medios de Contraste , Tomografía Computarizada por Rayos X , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ecocardiografía Transesofágica/métodos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento
16.
Eur J Clin Invest ; 54(8): e14209, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38597271

RESUMEN

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Terapia Antiplaquetaria Doble , Hemorragia , Inhibidores de Agregación Plaquetaria , Humanos , Apéndice Atrial/cirugía , Inhibidores de Agregación Plaquetaria/uso terapéutico , Terapia Antiplaquetaria Doble/métodos , Hemorragia/inducido químicamente , Anciano , Trombosis/prevención & control , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular/prevención & control , Estudios Observacionales como Asunto , Cierre del Apéndice Auricular Izquierdo
17.
Rev Cardiovasc Med ; 25(6): 192, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39076324

RESUMEN

Background: The goal of this study was to compare the procedural safety and long-term outcome associated with a combined catheter ablation and left atrial appendage occlusion (LAAO) procedure utilizing intracardiac echocardiography (ICE) guidance versus transesophageal echocardiography (TEE) guidance. The study focuses on implementing LAmbre and Watchman devices in patients diagnosed with nonvalvular atrial fibrillation (AF). Methods: A total of 363 patients diagnosed with nonvalvular AF and who underwent a combined procedure were prospectively enrolled between November 2017 and May 2022. Following 1:1 propensity score matching, the TEE group (n = 132) and ICE group (n = 132) were systematically compared in terms of the combined procedure, imaging parameters, events related to the procedure, and subsequent outcomes during follow-up, including mortality, stroke, bleeding, device-related thrombus (DRT), and peri-device leaks (PDLs). Results: The ICE group exhibited a significant reduction in total procedural duration (153.71 ± 31.71 vs. 174.74 ± 18.79 min), fluoroscopy radiation dosage (207.24 ± 108.39 vs. 268.61 ± 122.88 mGy), left atrial appendage occlusion procedure time (34.69 ± 10.91 vs. 51.46 ± 15.84 min), and contrast agent exposure (108.71 ± 37.59 vs. 158.41 ± 45.00 mL) compared to the TEE group. Angiography and ICE demonstrated a substantial correlation between the left atrial appendage (LAA) orifice and landing zone/LAA ostium (Pearson's correlation coefficient r = 0.808 and 0.536/0.697, two-tailed p < 0.001). No occurrences of device-related embolism, thromboembolism, significant bleeding, or unexpected fatalities were observed in either group. Comparable rates of all-cause death (0.76% vs. 0.76%), stroke or transient ischemic attack (2.27% vs. 1.52%), severe bleeding (1.52% vs. 0.76%), PDL (23.81% vs. 24.62%), and DRT (1.52% vs. 1.52%) were noted after an average follow-up of 18.46 ± 7.70 months in both groups, with no discernible differences. Multivariate logistic regression analysis identified a correlation between LAA velocity and the risk of PDL. Conclusions: The effectiveness and safety of ICE-guided combined treatment were demonstrated to be comparable to TEE guidance, accompanied by the additional advantages of decreased procedure time and fluoroscopy radiation exposure. Clinical Trial Registration: NCT04391504, https://register.clinicaltrials.gov.

18.
Rev Cardiovasc Med ; 25(1): 13, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39077658

RESUMEN

Background: Left atrial appendages (LAAs) play an important role in regulating left atrial function, and much evidence supports the possibility that changes in left atrial structure may cause or worsen mitral regurgitation. This study intended to investigate the outcomes of patients with mitral regurgitation who underwent left atrial appendage closure (resection or endocardial closure) during isolated surgical ablations. Methods: Patients with mild or moderate mitral regurgitation who received isolated surgical ablations for atrial fibrillation (AF) in our center from 2013 to 2022 were referred. During follow-up, each clinical visit was composed of medical interrogation, a 24 h Holter, and echocardiographic evaluation. Death, atrial fibrillation, worsening of mitral regurgitation, and stroke were evaluated as outcomes. Freedom from outcomes whose results were adjusted by inverse probability of treatment weighting for causal effects after acquiring propensity scores. Results: A total of 456 patients were enrolled in this study. During a median follow-up of 48 months, 30 deaths and 11 cases of stroke were observed. After adjustments, no significant differences in terms of death or stroke were observed among the three groups. Patients who underwent resection or endocardial closure during surgical ablations had a higher risk of mitral regurgitation worsening during follow-up (p < 0.05). During the whole follow-up, patients who underwent left atrial appendage interventions showed significantly larger left atrial and mitral annular diameters, as well as lower tethering height than those who had left atrial appendage preserved (all p < 0.05). Conclusions: Mitral regurgitation was more likely to get worse when patients with fundamental mitral diseases underwent LAA interventions during isolated surgical AF ablations. In the absence of LAA, the dilation of the left atrium and mitral annulus may ultimately lead to worsening of regurgitation.

19.
Rev Cardiovasc Med ; 25(1): 10, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39077666

RESUMEN

Background: The combination of left atrial appendage closure (LAAC) and catheter ablation (CA) in a single procedure is a safe and effective form of treatment for atrial fibrillation (AF). However, several findings have argued that LAAC might increase the risk of AF recurring. Therefore, this study investigated the impact of insufficient ablation on AF recurrence after the hybrid procedures of CA and LAAC. Methods: We reviewed 107 consecutive patients with AF who received the CA and LAAC hybrid procedures (combined group). In the case-control study, another 107 patients who underwent only CA (ablation group) were successfully matched using propensity score matching. After correcting the insufficient ablation, 107 consecutive patients were enrolled prospectively. During the follow-up period, postprocedural 24-hour monitor recordings and a portable electrocardiogram (ECG) monitoring device were used to detect AF recurrence. Transesophageal echocardiography was used to evaluate LAAC. Results: The combined group showed an increase in the risk of AF recurrence after 539.2 ± 304.4 days of follow-up (29.9% vs. 15.9%, p < 0.05). Interestingly, the duration of the procedure was not significantly prolonged when LAAC was added after CA in the combined group, while there was a higher number of ablating attempts, duration of ablation, and additional ablation in the ablation group for both radiofrequency and cryoballoon ablation. After correcting for the insufficient ablation, the corrected group showed a significant decrease in AF recurrence after 420.4 ± 204.8 days of follow-up. Conclusions: Insufficient ablation is common when combining CA and LAAC and may lead to the recurrence of atrial fibrillation. It should be corrected intentionally by sufficient ablation of the pulmonary vein antrum and additional ablation. Clinical Trial Registration: The prospective study is a sub-study of our CAGEDAF study that has already been registered (ChiCTR2000039746).

20.
Rev Cardiovasc Med ; 25(2): 60, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39077340

RESUMEN

Interventions in structural heart disease cover many catheter-based procedures for congenital and acquired conditions including valvular diseases, septal defects, arterial or venous obstructions, and fistulas. Among the available procedures, the most common are aortic valve implantation, mitral or tricuspid valve repair/implantation, left atrial appendage occlusion, and patent foramen ovale closure. Antithrombotic therapy for transcatheter structural heart disease interventions aims to prevent thromboembolic events and reduce the risk of short-term and long-term complications. The specific approach to antithrombotic therapy depends on the type of intervention and individual patient factors. In this review, we synopsize contemporary evidence on antithrombotic therapies for structural heart disease interventions and highlight the importance of a personalized approach. These recommendations may evolve over time as new evidence emerges and clinical guidelines are updated. Therefore, it's crucial for healthcare professionals to stay updated on the most recent guidelines and individualize therapy based on patient-specific factors and procedural considerations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA