Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 960
Filtrar
Más filtros

Intervalo de año de publicación
1.
Circulation ; 149(10): e937-e952, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-38314551

RESUMEN

Disorders of the cardiac rhythm may occur in both the fetus and neonate. Because of the immature myocardium, the hemodynamic consequences of either bradyarrhythmias or tachyarrhythmias may be far more significant than in mature physiological states. Treatment options are limited in the fetus and neonate because of limited vascular access, patient size, and the significant risk/benefit ratio of any intervention. In addition, exposure of the fetus or neonate to either persistent arrhythmias or antiarrhythmic medications may have yet-to-be-determined long-term developmental consequences. This scientific statement discusses the mechanism of arrhythmias, pharmacological treatment options, and distinct aspects of pharmacokinetics for the fetus and neonate. From the available current data, subjects of apparent consistency/consensus are presented, as well as future directions for research in terms of aspects of care for which evidence has not been established.


Asunto(s)
American Heart Association , Arritmias Cardíacas , Recién Nacido , Estados Unidos , Niño , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamiento farmacológico , Taquicardia , Feto , Electrofisiología
2.
J Cardiovasc Electrophysiol ; 35(7): 1351-1359, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38695242

RESUMEN

INTRODUCTION: Leadless pacemakers (LPM) have established themselves as the important therapeutic modality in management of selected patients with symptomatic bradycardia. To determine real-world utilization and in-hospital outcomes of LPM implantation since its approval by the Food and Drug Administration in 2016. METHODS: For this retrospective cohort study, data were extracted from the National Inpatient Sample database from the years 2016-2020. The outcomes analyzed in our study included implantation trends of LPM over study years, mortality, major complications (defined as pericardial effusion requiring intervention, any vascular complication, or acute kidney injury), length of stay, and cost of hospitalization. Implantation trends of LPM were assessed using linear regression. Using years 2016-2017 as a reference, adjusted outcomes of mortality, major complications, prolonged length of stay (defined as >6 days), and increased hospitalization cost (defined as median cost >34 098$) were analyzed for subsequent years using a multivariable logistic regression model. RESULTS: There was a gradual increased trend of LPM implantation over our study years (3230 devices in years 2016-2017 to 11 815 devices in year 2020, p for trend <.01). The adjusted mortality improved significantly after LPM implantation in subsequent years compared to the reference years 2016-2017 (aOR for the year 2018: 0.61, 95% CI: 0.51-0.73; aOR for the year 2019: 0.49, 95% CI: 0.41-0.59; and aOR for the year 2020: 0.52, 95% CI: 0.44-0.62). No differences in adjusted rates of major complications were demonstrated over the subsequent years. The adjusted cost of hospitalization was higher for the years 2019 (aOR: 1.33, 95% CI: 1.22-1.46) and 2020 (aOR: 1.69, 95% CI: 1.55-1.84). CONCLUSION: The contemporary US practice has shown significantly increased implantation rates of LPM since its approval with reduced rates of inpatient mortality.


Asunto(s)
Estimulación Cardíaca Artificial , Bases de Datos Factuales , Costos de Hospital , Tiempo de Internación , Marcapaso Artificial , Humanos , Marcapaso Artificial/tendencias , Marcapaso Artificial/economía , Estados Unidos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Resultado del Tratamiento , Costos de Hospital/tendencias , Factores de Tiempo , Persona de Mediana Edad , Estimulación Cardíaca Artificial/tendencias , Estimulación Cardíaca Artificial/economía , Estimulación Cardíaca Artificial/mortalidad , Estimulación Cardíaca Artificial/efectos adversos , Tiempo de Internación/tendencias , Factores de Riesgo , Anciano de 80 o más Años , Bradicardia/terapia , Bradicardia/mortalidad , Bradicardia/diagnóstico , Frecuencia Cardíaca , Mortalidad Hospitalaria/tendencias , Diseño de Equipo/tendencias
3.
Artículo en Inglés | MEDLINE | ID: mdl-38923693

RESUMEN

INTRODUCTION: Pacemaker-mediated tachycardia is a known arrhythmia in patients with dual chamber pacemakers and defibrillators and intact ventriculoatrial (VA) conduction. We report a case of pacemaker-mediated reentrant arrhythmia (PMRA) in a patient with an atrioventricular (AV) synchronous leadless pacemaker. METHODS AND RESULTS: A 91-year-old female presented with 2:1 AV conduction and received an AV synchronous leadless pacemaker. She had atrial mechanical sense-ventricular paced beats between heart rates of 80-100 bpm more than 80% of the time. She was found to have a new cardiomyopathy and was referred for placement of biventricular pacemaker. At the time of device implantation, her electrocardiogram showed ventricular pacing with a short RP interval and superiorly directed P waves. Changes in the ventricular pacing rate resulted in changes in the atrial rate. Following device placement, her heart rate decreased to the lower rate limit of her pacemaker. The atrial mechanical sense impulse most likely was generated by a retrograde conducted P wave resulting in near incessant PMRA. CONCLUSION: PMRA may occur in patients who receive an AV synchronous leadless pacemaker with intact VA conduction and sinoatrial node dysfunction. Due to the lower rates of PMRA, this arrhythmia may be underrecognized. Interventions for and implications of PMRA need further investigation.

4.
J Cardiovasc Electrophysiol ; 35(10): 2076-2080, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39160775

RESUMEN

INTRODUCTION: Cardioneuroablation (CNA) has proven effectiveness in addressing hypervagotonia symptoms, such as neurocardiogenic syncope. METHODS AND RESULTS: In this case, we present the first-time application of CNA in a case of vago-glossopharyngeal neuralgia (VGPN). A 59-year-old female with near-syncope, sinus bradycardia, and sinus pauses triggered by recurrent right-sided neck pain was diagnosed with VGPN. The patient underwent successful treatment with carbamazepine and CNA. Subsequent follow-up revealed the sustained absence of sinus bradycardia or pauses, even upon neck pain resurgence after discontinuing carbamazepine. CONCLUSION: In this patient, CNA successfully prevented pauses associated with VGPN, avoiding permanent pacemaker implantation.


Asunto(s)
Bradicardia , Enfermedades del Nervio Glosofaríngeo , Frecuencia Cardíaca , Humanos , Femenino , Persona de Mediana Edad , Bradicardia/fisiopatología , Bradicardia/diagnóstico , Bradicardia/terapia , Resultado del Tratamiento , Frecuencia Cardíaca/efectos de los fármacos , Enfermedades del Nervio Glosofaríngeo/diagnóstico , Enfermedades del Nervio Glosofaríngeo/cirugía , Enfermedades del Nervio Glosofaríngeo/fisiopatología , Carbamazepina/uso terapéutico , Dolor de Cuello/diagnóstico , Dolor de Cuello/terapia , Dolor de Cuello/etiología , Técnicas de Ablación
5.
Lupus ; 33(7): 685-692, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38571373

RESUMEN

OBJECTIVE: The aim of this study was to explore the parents' experiences of home monitoring of the fetal heart rhythm. Women with anti-SSA/Ro52 autoantibodies carry a 2%-3% risk of giving birth to a child with congenital heart block (CHB), following transplacental transfer and antibody-mediated inflammation in the fetal conduction system during 18th to 24th gestational week. Early detection and subsequent treatment have been reported to decrease morbidity and mortality. Therefore, home monitoring of the fetal heart rhythm by Doppler has been offered at our fetal cardiology center. This study was undertaken to explore the lived experience of the routine. METHODS: Participants were recruited from a single fetal cardiology center. Consecutive sampling was used. The inclusion criteria were women with SSA/Ro52 antibodies who had undergone Doppler examinations within the last two and a half years at the hospital and had monitored the fetal heartbeat at home. A semi-structured questionnaire was created, and the participants were interviewed individually. The interviews were transcribed verbatim and analyzed according to qualitative content analysis. RESULTS: The overall theme was defined as "walking on thin ice," with six underlying categories: reality, different strategies, gain and loss, healthcare providers, underlying tension, and conducting the examinations again, all with a focus on how to handle the home monitoring during the risk period. CONCLUSION: Both the mother and the co-parent expressed confidence in their own abilities and that the monitoring provided them with the advantage of growing a bond with the expected child. However, all the participants described a feeling of underlying tension during the risk period. The results show that home monitoring is not experienced as complicated or a burden for the parents-to-be and should be considered a vital part of the chain of care for mothers at risk for giving birth to a child with CHB. However, explaining the teamwork between the different caregivers, for the patients involved, their areas of expertise, and how they collaborate with the patient continues to be a pedagogic challenge and should be developed further.


Asunto(s)
Anticuerpos Antinucleares , Bloqueo Cardíaco , Frecuencia Cardíaca Fetal , Padres , Humanos , Femenino , Embarazo , Adulto , Padres/psicología , Bloqueo Cardíaco/congénito , Bloqueo Cardíaco/inmunología , Bloqueo Cardíaco/diagnóstico , Anticuerpos Antinucleares/sangre , Autoanticuerpos/sangre , Encuestas y Cuestionarios , Ribonucleoproteínas/inmunología , Monitoreo Fetal/métodos
6.
Ultrasound Obstet Gynecol ; 64(4): 486-492, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38642334

RESUMEN

OBJECTIVES: To determine the clinical course of fetal isolated non-immune-mediated second-degree atrioventricular block (AVB) and the factors associated with spontaneous recovery in these cases. METHODS: Fetuses with isolated non-immune-mediated second-degree AVB were recruited prospectively between 2014 and 2022. These fetuses were divided into two groups: those which recovered spontaneously and those which did not. Maternal and fetal characteristics and intrauterine and postnatal outcomes were compared between the two groups. RESULTS: The study cohort included 20 fetuses with isolated non-immune-mediated second-degree AVB, diagnosed at a median gestational age of 22.0 (range, 17.0-35.0) weeks. In 12 fetuses, 1:1 atrioventricular conduction was restored spontaneously in utero and there was no recurrence during the postnatal follow-up period. In the remaining eight fetuses, second-degree AVB was maintained and, in six of these, the pregnancy was terminated on parental request. Of the two liveborn children who had persistent second-degree AVB prenatally, one had progressed to complete AVB at the latest follow-up, at the age of 34 months, but was asymptomatic, without heart enlargement or dysfunction. The other child progressed to complete AVB after delivery and was diagnosed with type-2 long QT syndrome. This infant died aged 2 months. Fetuses in the group that recovered spontaneously had earlier gestational age at diagnosis (median, 20.0 (range, 17.0-26.0) vs 24.5 (range, 18.0-35.0) weeks; P = 0.004) and higher atrial rate at diagnosis (median, 147 (range, 130-160) vs 138 (range, 125-149) bpm; P = 0.006) in comparison with the group that did not recover spontaneously. The best cut-off values for prediction of failure to recover spontaneously were 22.5 weeks' gestational age at diagnosis and 144 bpm atrial rate at diagnosis, with sensitivities of 87.5% and 75.0%, respectively, and specificities of 92.0% and 87.5%, respectively. CONCLUSIONS: The outcome of 60% of fetuses with isolated non-immune-mediated second-degree AVB was favorable. Earlier gestational age and higher atrial rate at diagnosis were associated with spontaneous reversion to normal sinus rhythm. Prenatal genetic testing should be performed in cases with persistent AVB, to exclude heritable disorders including long QT syndrome. These findings provide important information for clinical management and prenatal counseling in these cases. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Bloqueo Atrioventricular , Edad Gestacional , Remisión Espontánea , Ultrasonografía Prenatal , Humanos , Femenino , Embarazo , Bloqueo Atrioventricular/embriología , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Estudios Prospectivos , Adulto , Enfermedades Fetales/diagnóstico , Enfermedades Fetales/fisiopatología , Recién Nacido , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiopatología , Corazón Fetal/embriología
7.
Pacing Clin Electrophysiol ; 47(2): 253-255, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37221934

RESUMEN

Heart block is rare in pediatrics with many possible causes. An association between complete heart block (CHB) and pathogenic titin (TTN) mutations have not been previously described. We report a 9-year-old female with history of leukodystrophy and family history of atrial fibrillation who presented with syncope and conduction abnormalities, including CHB. She underwent pacemaker implantation and genetic testing demonstrated a pathogenic TTN mutation likely responsible for her cardiac findings. Our case suggests an association between TTN mutations and conduction disease and emphasizes broadening gene testing in assessing these patients, especially when a family history is present.


Asunto(s)
Arritmias Cardíacas , Bloqueo Cardíaco , Humanos , Niño , Femenino , Conectina/genética , Trastorno del Sistema de Conducción Cardíaco , Mutación/genética
8.
Pacing Clin Electrophysiol ; 47(6): 776-779, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38583090

RESUMEN

BACKGROUND: Left bundle branch block (LBBB) induced cardiomyopathy is an increasingly recognized disease entity.  However, no clinical testing has been shown to be able to predict such an occurrence. CASE REPORT: A 70-year-old male with a prior history of LBBB with preserved ejection fraction (EF) and no other known cardiovascular conditions presented with presyncope, high-grade AV block, and heart failure with reduced EF (36%). His coronary angiogram was negative for any obstructive disease. No other known etiologies for cardiomyopathy were identified. Artificial intelligence-enabled ECGs performed 6 years prior to clinical presentation consistently predicted a high probability (up to 91%) of low EF. The patient successfully underwent left bundle branch area (LBBA) pacing with correction of the underlying LBBB. Subsequent AI ECGs showed a large drop in the probability of low EF immediately after LBBA pacing to 47% and then to 3% 2 months post procedure. His heart failure symptoms markedly improved and EF normalized to 54% at the same time. CONCLUSIONS: Artificial intelligence-enabled ECGS may help identify patients who are at risk of developing LBBB-induced cardiomyopathy and predict the response to LBBA pacing.


Asunto(s)
Inteligencia Artificial , Bloqueo de Rama , Cardiomiopatías , Electrocardiografía , Humanos , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Masculino , Anciano , Cardiomiopatías/fisiopatología , Cardiomiopatías/etiología , Cardiomiopatías/terapia , Valor Predictivo de las Pruebas
9.
Artículo en Inglés | MEDLINE | ID: mdl-39161109

RESUMEN

INTRODUCTION: Modern cardiovascular implantable electronic devices (CIEDs) have mechanisms that prevent damage from external electric shocks, and malfunction following accidental electrocution is rare. However, the effects of lightning injuries in patients with CIEDs are uncertain. CASE PRESENTATION: A 74-year-old man with a dual-chamber pacemaker due to complete heart block was struck by a lightning while farming. He had no serious injury at the time and sought medical evaluation 1 month later, when he presented with asymptomatic bradycardia. Device interrogation suggested major battery and lead damage, requiring extraction and subsequent placement of a new pacing system. DISCUSSION: While a previous report depicted pacing threshold elevation without extensive device impairment, our patient presented with major damage to the whole pacing system. The factors contributing to these divergent outcomes are unclear. Differences in injury mechanism, pacemaker model, and the pattern of electric current dispersion within the device may each play a part in this discrepancy.

10.
Artículo en Inglés | MEDLINE | ID: mdl-39382277

RESUMEN

INTRODUCTION: We investigated the effects of timing of detection and transplacental fluorinated steroid treatment on ventricular heart rate (HR) and age at pacemaker implantation in fetal third-degree atrioventricular block (AVB). MATERIAL AND METHODS: Twenty-five of 31 fetuses diagnosed with Ro/SSA autoantibody-positive AVB II-III at our tertiary fetal cardiology center (2000-2020) and AVB III as final feto-neonatal outcome were reviewed. RESULTS: AVB was detected approximately 5 weeks earlier in pregnancy if followed in a surveillance program compared to cases referred from primary care for bradycardia (20.6 [2.3] [mean (SD)] vs. 25.4 [3.2] weeks, p = 0.001). AVB detected before 24 weeks had higher HR than those detected later in gestation (63.3 [6.9] vs. 57.2 [6.9] bpm, p = 0.042), with a larger proportion having HR >60 bpm (80% vs. 33%, p = 0.041). The 17/25 cases that received treatment with fluorinated steroid were diagnosed earlier in gestation, with higher HR at diagnosis (61.7 [7.1] vs. 54.7 [6.3] bpm, p = 0.026), 1-2 weeks after diagnosis/treatment start, and before birth (65.4 [12.4] vs. 54.9 [5.7] bpm, p = 0.030) than untreated cases. Overall, 11 cases were commenced on betamimetics: three at diagnosis and eight at or after the examination made 1-2 weeks after diagnosis/treatment start, without any HR improvement. Two of 24 surviving babies were born preterm, and 4/24 received a neonatal pacemaker. Age at pacemaker implantation correlated significantly with HR before birth (Spearman R 0.57, p = 0.004), and fetuses with HR >60 bpm had a higher rate of pacemaker-free survival at three (90% vs. 40%, p = 0.018) and 12 months of age (80% vs. 13%, p = 0.002). The same trend was observed in pacemaker-free survival at 3 months of age in fluorinated steroid-treated compared to untreated cases (71% vs. 38%, ns). CONCLUSIONS: Our data confirm that AVB III detected earlier in gestation have a higher HR, and suggest that this higher HR can be successfully maintained to the end of gestation in cases treated with fluorinated steroids. Fetuses with HR >60 bpm before birth had a lower rate of pacemaker implantation at 3 and 12 months of age.

11.
Indian J Med Res ; 159(6): 695-701, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39382458

RESUMEN

Background & objectives Neuronal hypoxia associated with conditions like traumatic brain injury and cardiac tachyarrhythmia has been implicated in causing hypopituitarism. Individuals with complete heart block (CHB) may be predisposed to develop anterior pituitary hormone dysfunction in the long term. The objective of this study was to investigate anterior pituitary hormone functions in individuals after CHB. Methods This prospective cohort study included 30 individuals (21 men and 9 women) with CHB requiring pacemaker implantation, who were evaluated at admission and then at a mean follow up of 12.4 ± 2.2 months to look for development of any degree of hypopituitarism. In addition to the measurement of hormones like follicle-stimulating hormone (FSH), luteinising hormone (LH), thyroid stimulating hormone (TSH), total tetra iodothyronines (TT4), free tetraiodothyronines (FT4), cortisol, insulin-like growth factor-1 (IGF-1), testosterone and estradiol, a fixed-dose glucagon stimulation test (GST) was performed to assess growth hormone (GH) and adrenocorticotrophic hormone (ACTH) axis. Results The mean age of the participants was 64.9 ± 11.3 yr. At follow up evaluation, 17 (56.7%) had low serum IGF-1, and among them, seven (23%) had growth hormone deficiency (GHD) (peak GH <1.0 ng/ml after GST). Six participants (20%) had ACTH deficiency (peak cortisol <9 ug/dl after GST) and one had TSH deficiency. None had prolactin (PRL) or gonadotropin deficiency. Overall, hormone deficiencies were observed in nine patients (30%). Interpretation & conclusions This pilot study detected loss of anterior pituitary hormones in a significant number of individuals of CHB at 12 months follow up. Unrecognised hypopituitarism may have resulted in significant morbidity and mortality in these individuals.


Asunto(s)
Bloqueo Cardíaco , Hipopituitarismo , Marcapaso Artificial , Hormonas Adenohipofisarias , Humanos , Femenino , Masculino , Persona de Mediana Edad , Hipopituitarismo/sangre , Hipopituitarismo/fisiopatología , Hipopituitarismo/tratamiento farmacológico , Anciano , Bloqueo Cardíaco/sangre , Bloqueo Cardíaco/fisiopatología , Bloqueo Cardíaco/terapia , Hormonas Adenohipofisarias/sangre , Hormonas Adenohipofisarias/deficiencia , Factor I del Crecimiento Similar a la Insulina/metabolismo , Hormona Adrenocorticotrópica/sangre , Hormona Adrenocorticotrópica/deficiencia , Tirotropina/sangre , Estudios Prospectivos , Hidrocortisona/sangre , Hormona Folículo Estimulante/sangre
12.
Pediatr Cardiol ; 45(2): 441-445, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38145427

RESUMEN

Clinically significant bradycardia is an uncommon problem in children, but one that can cause significant morbidity and sometimes necessitates implantation of a pacemaker. The most common causes of bradycardia are complete heart block (CHB), which can be congenital or acquired, and sinus node dysfunction, which is rare in children with structurally normal hearts. Pacemaker is indicated as therapy for the majority of children with CHB, and while early mortality is lower in postnatally diagnosed CHB than in fetal CHB, it is still up to 16%. In young children, less invasive transvenous pacemaker systems can be technically challenging to place and carry a high risk of complications, often necessitating surgical epicardial pacemaker placement, which usually entails a median sternotomy. We report three cases of pediatric patients referred for pacemaker implantation for different types of bradycardia, treated at our institution with oral albuterol with therapeutic results that avoided the need for surgical pacemaker implantation at that time.


Asunto(s)
Bradicardia , Marcapaso Artificial , Humanos , Niño , Preescolar , Bradicardia/tratamiento farmacológico , Bradicardia/etiología , Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial/efectos adversos , Síndrome del Seno Enfermo/tratamiento farmacológico , Síndrome del Seno Enfermo/complicaciones , Administración Oral
13.
Pediatr Cardiol ; 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38413418

RESUMEN

Fetal arrhythmias are rare and carry significant morbidity and mortality without appropriate treatment. Initial reports exist of fetal arrhythmia in the setting of maternal COVID-19 infection. Our study sought to evaluate incidence of fetal arrhythmia before and during the COVID-19 pandemic at our institution. This retrospective cohort study from a tertiary care fetal cardiac center utilized the institutional REDCap database to search fetal arrhythmia diagnostic codes. Medical records of mother-fetus dyads were reviewed and data were collected on diagnoses, gestational age, treatment regimen, and postnatal outcomes. Patients were divided into pre-COVID and peri-COVID segments. 8368 total pregnancies were evaluated during the 7.3 years of study period. Forty-five patients (0.5%) had a significant fetal arrhythmia and were included in this study: 19 (42%) in the pre-COVID-19 group and 26 (58%) in the peri-COVID-19 group. No patients had associated congenital heart disease. There was a notable increase in the incidence of fetal supraventricular tachycardia (SVT) (1.82 per 1000 vs 2.65 per 1000 pregnancies) and complete heart block (1.04 per 1000 vs 1.77 per 1000 pregnancies) but no apparent change in other tachyarrhythmias during the COVID era. The proportion of antibody-mediated complete heart block increased from 50 to 87.5%. There was also an increase in the percentage of SVT patients requiring postnatal treatment during COVID-19 (53.8% vs 62.5%). Our experience shows an increased incidence of some fetal arrhythmia diagnoses during the COVID-19 pandemic. Additional multi-center studies will be necessary to fully evaluate the increased burden of fetal arrhythmias during the COVID-19 era as well as to elucidate etiology.

14.
Pediatr Cardiol ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689022

RESUMEN

Transcatheter closure of perimembranous ventricular septal defect (PmVSD) is an established procedure. However, the occurrence of complete heart block limits its scope. The newer KONAR-MF™ occluder has specific design characteristics that may improve the safety of PmVSD closure. The objective of the study was to describe the efficacy and mid-term follow-up of transcatheter closure of PmVSD using KONAR-MF™. The study was conducted prospectively in 3 Indian centers (January 2018-December 2022). PmVSD closure was done by both antegrade and retrograde methods, and patients were followed up at 1, 3, 6, 12 months, and annually after that. 121 out of 123 patients were included with the following characteristics: median age 4.4 (0.18-40) years; weight 15 (2.1-88) kg; mean Qp/Qs ratio 1.87 ± 0.52 and pulmonary artery mean pressure: 22 ± 6.9 mmHg. The procedure was successful in all but 3; the device was removed due to significant residual shunt (n = 2) and new development of aortic regurgitation (AR) (≥ mild) in 1. The median defect size was 5.2 (2.5-12) mm. Device sizes from 6/4 to 14/12 were deployed (median fluoroscopy time 13.3 min; range 3.6-47.8). Shunt occlusion rates were 90%-Immediate, 95%-pre-discharge, and 97%-1 month, with no instances of complete heart block after the procedure and during follow-up. Six had new onset AR (mild: 2, trivial 4), and one had increased tricuspid regurgitation. All patients were well during follow-up (median: 20 months; range: 6-46). The new KONAR-MF™ occluder appears to be a promising and safe alternative for the closure of the PmVSD; further long-term follow is merited.

15.
Cardiol Young ; : 1-3, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38682551

RESUMEN

When the atrioventricular node is damaged, accessory pathways can perform primary atrioventricular conduction but may spontaneously degrade during childhood. After surgical atrial septal defect repair during infancy, an adolescent male presented with fatigue due to iatrogenic complete atrioventricular node block with a degrading antegrade accessory pathway resulting in symptomatic bradyarrhythmia.

16.
J Emerg Med ; 66(4): e492-e502, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38453595

RESUMEN

BACKGROUND: Transvenous pacemaker placement is an integral component of therapy for severe dysrhythmias and a core skill in emergency medicine. OBJECTIVE: This narrative review provides a focused evaluation of transvenous pacemaker placement in the emergency department setting. DISCUSSION: Temporary cardiac pacing can be a life-saving procedure. Indications for pacemaker placement include hemodynamic instability with symptomatic bradycardia secondary to atrioventricular block and sinus node dysfunction; overdrive pacing in unstable tachydysrhythmias, such as torsades de pointes; and failure of transcutaneous pacing. Optimal placement sites include the right internal jugular vein and left subclavian vein. Insertion first includes placement of a central venous catheter. The pacing wire with balloon is then advanced until electromechanical capture is obtained with the pacer in the right ventricle. Ultrasound can be used to guide and confirm lead placement using the subxiphoid or modified subxiphoid approach. The QRS segment will demonstrate ST segment elevation once the pacing wire tip contacts the endocardial wall. If mechanical capture is not achieved with initial placement of the transvenous pacer, the clinician must consider several potential issues and use an approach to evaluating the equipment and correcting any malfunction. Although life-saving in the appropriate patient, complications may occur from central venous access, right heart catheterization, and the pacing wire. CONCLUSIONS: An understanding of transvenous pacemaker placement is essential for emergency clinicians.


Asunto(s)
Marcapaso Artificial , Humanos , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Bradicardia/etiología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicaciones , Síndrome del Seno Enfermo/terapia
17.
Int J Mol Sci ; 25(10)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38791261

RESUMEN

This study, conducted by searching keywords such as "maternal lupus", "neonatal lupus", and "congenital heart block" in databases including PubMed and Scopus, provides a detailed narrative review on fetal and neonatal lupus. Autoantibodies like anti-Ro/SSA and anti-La/SSB may cross the placenta and cause complications in neonates, such as congenital heart block (CHB). Management options involve hydroxychloroquine, which is able to counteract some of the adverse events, although the drug needs to be used carefully because of its impact on the QTc interval. Advanced pacing strategies for neonates with CHB, especially in severe forms like hydrops, are also assessed. This review emphasizes the need for interdisciplinary care by rheumatologists, obstetricians, and pediatricians in order to achieve the best maternal and neonatal health in lupus pregnancies. This multidisciplinary approach seeks to improve the outcomes and management of the disease, decreasing the burden on mothers and their infants.


Asunto(s)
Lupus Eritematoso Sistémico , Placenta , Humanos , Embarazo , Femenino , Lupus Eritematoso Sistémico/inmunología , Lupus Eritematoso Sistémico/terapia , Lupus Eritematoso Sistémico/congénito , Placenta/metabolismo , Placenta/inmunología , Recién Nacido , Bloqueo Cardíaco/congénito , Bloqueo Cardíaco/terapia , Bloqueo Cardíaco/inmunología , Complicaciones del Embarazo/inmunología , Complicaciones del Embarazo/terapia , Autoanticuerpos/inmunología , Intercambio Materno-Fetal , Hidroxicloroquina/uso terapéutico
18.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702135

RESUMEN

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
19.
Rev Cardiovasc Med ; 24(8): 243, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39076697

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) is an effective alternative treatment for patients with aortic stenosis (AS) who have intermediate to high surgical risk or who are inoperable. However, the incidence of conduction abnormalities is high after TAVR, which can reduce the effectiveness of the surgery. Our research objective is to explore the risk factors of new-onset conduction abnormalities after TAVR, providing reference value for clinical doctors to better prevent and treat conduction abnormalities. Methods: Patients who underwent TAVR were divided into those who developed heart block and those who did not. Baseline clinical characteristics, cardiac structural parameters, procedural characteristics, electrocardiogram (ECG) changes before and after TAVR ( △ = postoperative minus preoperative), and surgical complications were compared. Logistic regression was applied to identify significant risk factors for new-onset heart block. Results: We studied 93 patients, of whom 34.4% developed heart blocks. Univariate logistic regression showed that prior history of malignancy, atrial fibrillation, preoperative high-level total cholesterol and low-density lipoprotein cholesterol (LDL-C), △ HR, △ QRS interval, △ QT interval, and △ QTc interval were risk factors of new-onset heart block after TAVR. Multivariate analysis showed that preoperative high-level LDL-C and △ QRS interval remained significant independent risk factors after adjusting for potential confounds. Conclusions: Heart block is the most common complication of TAVR, and its significant independent risk factors include high-level LDL-C and △ QRS interval.

20.
Catheter Cardiovasc Interv ; 102(5): 919-928, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37698294

RESUMEN

BACKGROUND: High-grade or complete atrioventricular block (AVB) requiring permanent pacemaker (PPM) implantation is a known complication of transcatheter aortic valve replacement (TAVR). Wenckebach AVB induced by rapid atrial pacing (RAP) after TAVR was previously demonstrated in an observational analysis to be an independent predictor for PPM. We sought to investigate the utility of both pre- and post-TAVR RAP in predicting PPM implantation. METHODS: In a single-center, prospective study, 421 patients underwent TAVR with balloon-expandable valves (BEV) between April 2020 and August 2021. Intraprocedural RAP was performed in patients without a pre-existing pacemaker, atrial fibrillation/flutter, or intraprocedural complete AVB to assess for RAP-induced Wenckebach AVB. The primary outcome was PPM within 30 days after TAVR. RESULTS: RAP was performed in 253 patients, of whom 91.3% underwent post-TAVR RAP and 61.2% underwent pre-TAVR RAP. The overall PPM implantation rate at 30 days was 9.9%. Although there was a numerically higher rate of PPM at 30 days in patients with RAP-induced Wenckebach AVB, it did not reach statistical significance (13.3% vs. 8.4%, p = 0.23). In a multivariable analysis, RAP-induced Wenckebach was not an independent predictor for PPM implantation at 30 days after TAVR. PPM rates at 30 days were comparable in patients with or without pre-TAVR pacing-induced Wenckebach AVB (11.8% vs. 8.2%, p = 0.51) and post-TAVR pacing-induced Wenckebach AVB (10.2% vs. 5.8%, p = 0.25). CONCLUSION: In patients who underwent TAVR with BEV, there were no statistically significant differences in PPM implantation rates at 30 days regardless of the presence or absence of RAP-induced Wenckebach AVB. Due to conflicting results between the present study and the prior observational analysis, future studies with larger sample sizes are warranted to determine the role of RAP during TAVR as a risk-stratification tool for significant AVB requiring PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Bloqueo Atrioventricular , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Estudios Prospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Marcapaso Artificial/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA