Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 767
Filtrar
Más filtros

Intervalo de año de publicación
1.
Annu Rev Med ; 75: 263-276, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-37827195

RESUMEN

Interventional pulmonary medicine has developed as a subspecialty focused on the management of patients with complex thoracic disease. Leveraging minimally invasive techniques, interventional pulmonologists diagnose and treat pathologies that previously required more invasive options such as surgery. By mitigating procedural risk, interventional pulmonologists have extended the reach of care to a wider pool of vulnerable patients who require therapy. Endoscopic innovations, including endobronchial ultrasound and robotic and electromagnetic bronchoscopy, have enhanced the ability to perform diagnostic procedures on an ambulatory basis. Therapeutic procedures for patients with symptomatic airway disease, pleural disease, and severe emphysema have provided the ability to palliate symptoms. The combination of medical and procedural expertise has made interventional pulmonologists an integral part of comprehensive care teams for patients with oncologic, airway, and pleural needs. This review surveys key areas in which interventional pulmonologists have impacted the care of thoracic disease through bronchoscopic intervention.


Asunto(s)
Neumología , Enfermedades Torácicas , Humanos , Neumología/métodos , Broncoscopía/métodos
2.
Magn Reson Med ; 92(4): 1471-1483, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38726472

RESUMEN

PURPOSE: To characterize the dependence of Xe-MRI gas transfer metrics upon age, sex, and lung volume in a group of healthy volunteers. METHODS: Sixty-five subjects with no history of chronic lung disease were assessed with 129Xe-MRI using a four-echo 3D radial spectroscopic imaging sequence and a dose of xenon titrated according to subject height that was inhaled from a lung volume of functional residual capacity (FRC). Imaging was repeated in 34 subjects at total lung capacity (TLC). Regional maps of the fractions of dissolved xenon in red blood cells (RBC), membrane (M), and airspace (Gas) were acquired at an isotropic resolution of 2 cm, from which global averages of the ratios RBC:M, RBC:Gas, and M:Gas were computed. RESULTS: Data from 26 males and 36 females with a median age of 43 y (range: 20-69 y) were of sufficient quality to analyze. Age (p = 0.0006) and sex (p < 0.0001) were significant predictors for RBC:M, and a linear regression showed higher values and steeper decline in males: RBC:M(Males) = -0.00362 × Age + 0.60 (p = 0.01, R2 = 0.25); RBC:M(Females) = -0.00170 × Age + 0.44 (p = 0.02, R2 = 0.15). Similarly, age and sex were significant predictors for RBC:Gas but not for M:Gas. RBC:M, M:Gas and RBC:Gas were significantly lower at TLC than at FRC (plus inhaled volume), with an average 9%, 30% and 35% decrease, respectively. CONCLUSION: Expected age and sex dependence of pulmonary function concurs with 129Xe RBC:M imaging results, demonstrating that these variables must be considered when reporting Xe-MRI metrics. Xenon doses and breathing maneuvers should be controlled due to the strong dependence of Xe-MRI metrics upon lung volume.


Asunto(s)
Pulmón , Imagen por Resonancia Magnética , Isótopos de Xenón , Humanos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Imagen por Resonancia Magnética/métodos , Anciano , Pulmón/diagnóstico por imagen , Adulto Joven , Intercambio Gaseoso Pulmonar , Factores Sexuales , Factores de Edad , Mediciones del Volumen Pulmonar , Eritrocitos
3.
Rheumatology (Oxford) ; 63(4): 1162-1171, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-37458486

RESUMEN

OBJECTIVES: Fibrotic interstitial lung disease (ILD) is a progressive lung disease characterized by loss of lung volume, resulting in a leading cause of death in patients with RA. Crucially, acute exacerbation (AE) of ILD shows higher morbidity and mortality with rapid deterioration of the lungs. However, a quantitative assessment for physiological changes at AE has yet to be performed. This study hypothesized that quantitative assessments of lung volume (LV) accurately indicate disease severity and mortality risk in patients with AE-RA-ILD. METHODS: This multicentre cohorts study quantitatively assessed physiological changes of RA-ILD at diagnosis (n = 54), at AE (discovery-cohorts; n = 20, and validation-cohort; n = 33), and controls (n = 35) using 3D CT (3D-CT) images. LV was quantitatively measured using 3D-CT and standardized by predicted forced vital capacity. RESULTS: Patients with RA-ILD at diagnosis showed decreased LV, predominantly in lower lobes, compared with controls. Further substantial volume loss was found in upper- and lower lobes at AE compared with those at diagnosis. During AE, decreased standardized 3D-CT LV was associated with a worse prognosis in both cohorts. Subsequently, standardized 3D-CT LV was identified as a significant prognostic factor independent of age, sex and the presence of UIP pattern on CT by multivariate analyses. Notably, a composite model of age and standardized 3D-CT LV successfully classified mortality risk in patients with AE-RA-ILD. CONCLUSION: Volume loss at AE in patients with RA-ILD was associated with increased mortality. Assessing physiological change using standardized 3D-CT might help evaluate disease severity and mortality risk in patients with AE-RA-ILD.


Asunto(s)
Artritis Reumatoide , Enfermedades Pulmonares Intersticiales , Humanos , Artritis Reumatoide/complicaciones , Artritis Reumatoide/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/etiología , Enfermedades Pulmonares Intersticiales/complicaciones , Pulmón/diagnóstico por imagen , Pronóstico , Capacidad Vital , Tomografía Computarizada por Rayos X , Estudios Retrospectivos
4.
Ann Surg Oncol ; 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38864984

RESUMEN

PURPOSE: We elucidated the effects of planned resection volume on postoperative pulmonary function and changes in residual lung volume during segmentectomy. METHODS: This study included patients who underwent thoracoscopic segmentectomy between January 2017 and December 2022 and met eligibility criteria. Pre- and post-resection spirometry and computed tomography were performed. Three-dimensional reconstructions were performed by using computed tomography images to calculate the volumes of the resected, remaining, and nonoperative side regions. Based on the resected region volume, patients were divided into the higher and lower volume segmentectomy groups. Changes in lung volume and pulmonary function before and after the surgery were comparatively analyzed. RESULTS: The median percentage of resected lung volume was 10.9%, forming the basis for categorizing patients into the two groups. Postoperative forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) ratios to preoperative measurements in both groups did not differ significantly (FEV1, p = 0.254; FVC, p = 0.777). Postoperative FEV1 and FVC ratios to their predicted postoperative values were significantly higher in the higher volume segmentectomy group than in the lower volume segmentectomy group (FEV1, p = 0003; FVC, p < 0.001). The higher volume segmentectomy group showed significantly greater post-to-preoperative lung volume ratio in overall, contralateral, ipsilateral, residual lobe and residual segment than the lower volume segmentectomy group. CONCLUSIONS: Postoperative respiratory function did not differ significantly between the higher- and lower-volume segmentectomy groups, indicating improved respiratory function because of substantial postoperative residual lung expansion. Our findings would aid in determining the extent of resection during segmentectomy.

5.
Respir Res ; 25(1): 298, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39113017

RESUMEN

BACKGROUND: Increasing functional residual capacity (FRC) or tidal volume (VT) reduces airway resistance and attenuates the response to bronchoconstrictor stimuli in animals and humans. What is unknown is which one of the above mechanisms is more effective in modulating airway caliber and whether their combination yields additive or synergistic effects. To address this question, we investigated the effects of increased FRC and increased VT in attenuating the bronchoconstriction induced by inhaled methacholine (MCh) in healthy humans. METHODS: Nineteen healthy volunteers were challenged with a single-dose of MCh and forced oscillation was used to measure inspiratory resistance at 5 and 19 Hz (R5 and R19), their difference (R5-19), and reactance at 5 Hz (X5) during spontaneous breathing and during imposed breathing patterns with increased FRC, or VT, or both. Importantly, in our experimental design we held the product of VT and breathing frequency (BF), i.e, minute ventilation (VE) fixed so as to better isolate the effects of changes in VT alone. RESULTS: Tripling VT from baseline FRC significantly attenuated the effects of MCh on R5, R19, R5-19 and X5. Doubling VT while halving BF had insignificant effects. Increasing FRC by either one or two VT significantly attenuated the effects of MCh on R5, R19, R5-19 and X5. Increasing both VT and FRC had additive effects on R5, R19, R5-19 and X5, but the effect of increasing FRC was more consistent than increasing VT thus suggesting larger bronchodilation. When compared at iso-volume, there were no differences among breathing patterns with the exception of when VT was three times larger than during spontaneous breathing. CONCLUSIONS: These data show that increasing FRC and VT can attenuate induced bronchoconstriction in healthy humans by additive effects that are mainly related to an increase of mean operational lung volume. We suggest that static stretching as with increasing FRC is more effective than tidal stretching at constant VE, possibly through a combination of effects on airway geometry and airway smooth muscle dynamics.


Asunto(s)
Broncoconstricción , Cloruro de Metacolina , Volumen de Ventilación Pulmonar , Humanos , Broncoconstricción/efectos de los fármacos , Broncoconstricción/fisiología , Volumen de Ventilación Pulmonar/fisiología , Volumen de Ventilación Pulmonar/efectos de los fármacos , Masculino , Femenino , Adulto , Adulto Joven , Cloruro de Metacolina/administración & dosificación , Broncoconstrictores/administración & dosificación , Pruebas de Provocación Bronquial/métodos , Capacidad Residual Funcional/fisiología , Capacidad Residual Funcional/efectos de los fármacos , Voluntarios Sanos , Resistencia de las Vías Respiratorias/efectos de los fármacos , Resistencia de las Vías Respiratorias/fisiología , Pulmón/efectos de los fármacos , Pulmón/fisiología , Volumen Espiratorio Forzado/fisiología , Volumen Espiratorio Forzado/efectos de los fármacos
6.
Respir Res ; 25(1): 264, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38965590

RESUMEN

BACKGROUND: Bronchoscopic lung volume reduction (BLVR) with one-way endobronchial valves (EBV) has better outcomes when the target lobe has poor collateral ventilation, resulting in complete lobe atelectasis. High-inspired oxygen fraction (FIO2) promotes atelectasis through faster gas absorption after airway occlusion, but its application during BLVR with EBV has been poorly understood. We aimed to investigate the real-time effects of FIO2 on regional lung volumes and regional ventilation/perfusion by electrical impedance tomography (EIT) during BLVR with EBV. METHODS: Six piglets were submitted to left lower lobe occlusion by a balloon-catheter and EBV valves with FIO2 0.5 and 1.0. Regional end-expiratory lung impedances (EELI) and regional ventilation/perfusion were monitored. Local pocket pressure measurements were obtained (balloon occlusion method). One animal underwent simultaneous acquisitions of computed tomography (CT) and EIT. Regions-of-interest (ROIs) were right and left hemithoraces. RESULTS: Following balloon occlusion, a steep decrease in left ROI-EELI with FIO2 1.0 occurred, 3-fold greater than with 0.5 (p < 0.001). Higher FIO2 also enhanced the final volume reduction (ROI-EELI) achieved by each valve (p < 0.01). CT analysis confirmed the denser atelectasis and greater volume reduction achieved by higher FIO2 (1.0) during balloon occlusion or during valve placement. CT and pocket pressure data agreed well with EIT findings, indicating greater strain redistribution with higher FIO2. CONCLUSIONS: EIT demonstrated in real-time a faster and more complete volume reduction in the occluded lung regions under high FIO2 (1.0), as compared to 0.5. Immediate changes in the ventilation and perfusion of ipsilateral non-target lung regions were also detected, providing better estimates of the full impact of each valve in place. TRIAL REGISTRATION: Not applicable.


Asunto(s)
Broncoscopía , Impedancia Eléctrica , Animales , Porcinos , Broncoscopía/métodos , Neumonectomía/métodos , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Pulmón/cirugía , Pulmón/fisiología , Tomografía/métodos , Atelectasia Pulmonar/diagnóstico por imagen , Atelectasia Pulmonar/fisiopatología , Mediciones del Volumen Pulmonar/métodos , Factores de Tiempo
7.
Am J Obstet Gynecol ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838912

RESUMEN

BACKGROUND: A major goal of contemporary obstetrical practice is to optimize fetal growth and development throughout pregnancy. To date, fetal growth during prenatal care is assessed by performing ultrasonographic measurement of 2-dimensional fetal biometry to calculate an estimated fetal weight. Our group previously established 2-dimensional fetal growth standards using sonographic data from a large cohort with multiple sonograms. A separate objective of that investigation involved the collection of fetal volumes from the same cohort. OBJECTIVE: The Fetal 3D Study was designed to establish standards for fetal soft tissue and organ volume measurements by 3-dimensional ultrasonography and compare growth trajectories with conventional 2-dimensional measures where applicable. STUDY DESIGN: The National Institute of Child Health and Human Development Fetal 3D Study included research-quality images of singletons collected in a prospective, racially and ethnically diverse, low-risk cohort of pregnant individuals at 12 U.S. sites, with up to 5 scans per fetus (N=1730 fetuses). Abdominal subcutaneous tissue thickness was measured from 2-dimensional images and fetal limb soft tissue parameters extracted from 3-dimensional multiplanar views. Cerebellar, lung, liver, and kidney volumes were measured using virtual organ computer aided analysis. Fractional arm and thigh total volumes, and fractional lean limb volumes were measured, with fractional limb fat volume calculated by subtracting lean from total. For each measure, weighted curves (fifth, 50th, 95th percentiles) were derived from 15 to 41 weeks' using linear mixed models for repeated measures with cubic splines. RESULTS: Subcutaneous thickness of the abdomen, arm, and thigh increased linearly, with slight acceleration around 27 to 29 weeks. Fractional volumes of the arm, thigh, and lean limb volumes increased along a quadratic curvature, with acceleration around 29 to 30 weeks. In contrast, growth patterns for 2-dimensional humerus and femur lengths demonstrated a logarithmic shape, with fastest growth in the second trimester. The mid-arm area curve was similar in shape to fractional arm volume, with an acceleration around 30 weeks, whereas the curve for the lean arm area was more gradual. The abdominal area curve was similar to the mid-arm area curve with an acceleration around 29 weeks. The mid-thigh and lean area curves differed from the arm areas by exhibiting a deceleration at 39 weeks. The growth curves for the mid-arm and thigh circumferences were more linear. Cerebellar 2-dimensional diameter increased linearly, whereas cerebellar 3-dimensional volume growth gradually accelerated until 32 weeks followed by a more linear growth. Lung, kidney, and liver volumes all demonstrated gradual early growth followed by a linear acceleration beginning at 25 weeks for lungs, 26 to 27 weeks for kidneys, and 29 weeks for liver. CONCLUSION: Growth patterns and timing of maximal growth for 3-dimensional lean and fat measures, limb and organ volumes differed from patterns revealed by traditional 2-dimensional growth measures, suggesting these parameters reflect unique facets of fetal growth. Growth in these three-dimensional measures may be altered by genetic, nutritional, metabolic, or environmental influences and pregnancy complications, in ways not identifiable using corresponding 2-dimensional measures. Further investigation into the relationships of these 3-dimensional standards to abnormal fetal growth, adverse perinatal outcomes, and health status in postnatal life is warranted.

8.
J Surg Res ; 298: 251-259, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38636181

RESUMEN

INTRODUCTION: This study is a retrospective study. This study aims to explore the association between lobectomy in lung cancer patients and subsequent compensatory lung growth (CLG), and to identify factors that may be associated with variations in CLG. METHODS: 207 lung cancer patients who underwent lobectomy at Yunnan Cancer Hospital between January 2020 and December 2020. All patients had stage IA primary lung cancer and were performed by the same surgical team. And computed tomography examinations were performed before and 1 y postoperatively. Based on computed tomography images, the volume of each lung lobe was measured using computer software and manual, the radiological lung weight was calculated. And multiple linear regressions were used to analyze the factors related to the increase in postoperative lung weight. RESULTS: One year after lobectomy, the radiological lung weight increased by an average of 112.4 ± 20.8%. Smoking history, number of resected lung segments, preoperative low attenuation volume, intraoperative arterial oxygen partial pressure/fraction of inspired oxygen ratio and postoperative visual analog scale scores at 48 h were significantly associated with postoperative radiological lung weight gain. CONCLUSIONS: Our results suggest that CLG have occurred after lobectomy in adults. In addition, anesthetists should maintain high arterial oxygen partial pressure/fraction of inspired oxygen ratio during one-lung ventilation and improve acute postoperative pain to benefit CLG.


Asunto(s)
Neoplasias Pulmonares , Pulmón , Neumonectomía , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Femenino , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Pulmón/crecimiento & desarrollo , Anciano , Adulto , Tamaño de los Órganos , Periodo Posoperatorio
9.
Crit Care ; 28(1): 142, 2024 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689313

RESUMEN

RATIONALE: End-expiratory lung volume (EELV) is reduced in mechanically ventilated patients, especially in pathologic conditions. The resulting heterogeneous distribution of ventilation increases the risk for ventilation induced lung injury. Clinical measurement of EELV however, remains difficult. OBJECTIVE: Validation of a novel continuous capnodynamic method based on expired carbon dioxide (CO2) kinetics for measuring EELV in mechanically ventilated critically-ill patients. METHODS: Prospective study of mechanically ventilated patients scheduled for a diagnostic computed tomography exploration. Comparisons were made between absolute and corrected EELVCO2 values, the latter accounting for the amount of CO2 dissolved in lung tissue, with the reference EELV measured by computed tomography (EELVCT). Uncorrected and corrected EELVCO2 was compared with total CT volume (density compartments between - 1000 and 0 Hounsfield units (HU) and functional CT volume, including density compartments of - 1000 to - 200HU eliminating regions of increased shunt. We used comparative statistics including correlations and measurement of accuracy and precision by the Bland Altman method. MEASUREMENTS AND MAIN RESULTS: Of the 46 patients included in the final analysis, 25 had a diagnosis of ARDS (24 of which COVID-19). Both EELVCT and EELVCO2 were significantly reduced (39 and 40% respectively) when compared with theoretical values of functional residual capacity (p < 0.0001). Uncorrected EELVCO2 tended to overestimate EELVCT with a correlation r2 0.58; Bias - 285 and limits of agreement (LoA) (+ 513 to - 1083; 95% CI) ml. Agreement improved for the corrected EELVCO2 to a Bias of - 23 and LoA of (+ 763 to - 716; 95% CI) ml. The best agreement of the method was obtained by comparison of corrected EELVCO2 with functional EELVCT with a r2 of 0.59; Bias - 2.75 (+ 755 to - 761; 95% CI) ml. We did not observe major differences in the performance of the method between ARDS (most of them COVID related) and non-ARDS patients. CONCLUSION: In this first validation in critically ill patients, the capnodynamic method provided good estimates of both total and functional EELV. Bias improved after correcting EELVCO2 for extra-alveolar CO2 content when compared with CT estimated volume. If confirmed in further validations EELVCO2 may become an attractive monitoring option for continuously monitor EELV in critically ill mechanically ventilated patients. TRIAL REGISTRATION: clinicaltrials.gov (NCT04045262).


Asunto(s)
Capnografía , Enfermedad Crítica , Mediciones del Volumen Pulmonar , Humanos , Masculino , Femenino , Enfermedad Crítica/terapia , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Mediciones del Volumen Pulmonar/métodos , Capnografía/métodos , Respiración Artificial/métodos , COVID-19 , Tomografía Computarizada por Rayos X/métodos , Adulto
10.
Crit Care ; 28(1): 228, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38982466

RESUMEN

BACKGROUND: Adjusting trunk inclination from a semi-recumbent position to a supine-flat position or vice versa in patients with respiratory failure significantly affects numerous aspects of respiratory physiology including respiratory mechanics, oxygenation, end-expiratory lung volume, and ventilatory efficiency. Despite these observed effects, the current clinical evidence regarding this positioning manoeuvre is limited. This study undertakes a scoping review of patients with respiratory failure undergoing mechanical ventilation to assess the effect of trunk inclination on physiological lung parameters. METHODS: The PubMed, Cochrane, and Scopus databases were systematically searched from 2003 to 2023. INTERVENTIONS: Changes in trunk inclination. MEASUREMENTS: Four domains were evaluated in this study: 1) respiratory mechanics, 2) ventilation distribution, 3) oxygenation, and 4) ventilatory efficiency. RESULTS: After searching the three databases and removing duplicates, 220 studies were screened. Of these, 37 were assessed in detail, and 13 were included in the final analysis, comprising 274 patients. All selected studies were experimental, and assessed respiratory mechanics, ventilation distribution, oxygenation, and ventilatory efficiency, primarily within 60 min post postural change. CONCLUSION: In patients with acute respiratory failure, transitioning from a supine to a semi-recumbent position leads to decreased respiratory system compliance and increased airway driving pressure. Additionally, C-ARDS patients experienced an improvement in ventilatory efficiency, which resulted in lower PaCO2 levels. Improvements in oxygenation were observed in a few patients and only in those who exhibited an increase in EELV upon moving to a semi-recumbent position. Therefore, the trunk inclination angle must be accurately reported in patients with respiratory failure under mechanical ventilation.


Asunto(s)
Insuficiencia Respiratoria , Humanos , Insuficiencia Respiratoria/fisiopatología , Insuficiencia Respiratoria/terapia , Respiración Artificial/métodos , Mecánica Respiratoria/fisiología , Postura/fisiología , Posicionamiento del Paciente/métodos , Torso/fisiopatología , Torso/fisiología
11.
Crit Care ; 28(1): 82, 2024 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-38491457

RESUMEN

BACKGROUND: Prone positioning (PP) homogenizes ventilation distribution and may limit ventilator-induced lung injury (VILI) in patients with moderate to severe acute respiratory distress syndrome (ARDS). The static and dynamic components of ventilation that may cause VILI have been aggregated in mechanical power, considered a unifying driver of VILI. PP may affect mechanical power components differently due to changes in respiratory mechanics; however, the effects of PP on lung mechanical power components are unclear. This study aimed to compare the following parameters during supine positioning (SP) and PP: lung total elastic power and its components (elastic static power and elastic dynamic power) and these variables normalized to end-expiratory lung volume (EELV). METHODS: This prospective physiologic study included 55 patients with moderate to severe ARDS. Lung total elastic power and its static and dynamic components were compared during SP and PP using an esophageal pressure-guided ventilation strategy. In SP, the esophageal pressure-guided ventilation strategy was further compared with an oxygenation-guided ventilation strategy defined as baseline SP. The primary endpoint was the effect of PP on lung total elastic power non-normalized and normalized to EELV. Secondary endpoints were the effects of PP and ventilation strategies on lung elastic static and dynamic power components non-normalized and normalized to EELV, respiratory mechanics, gas exchange, and hemodynamic parameters. RESULTS: Lung total elastic power (median [interquartile range]) was lower during PP compared with SP (6.7 [4.9-10.6] versus 11.0 [6.6-14.8] J/min; P < 0.001) non-normalized and normalized to EELV (3.2 [2.1-5.0] versus 5.3 [3.3-7.5] J/min/L; P < 0.001). Comparing PP with SP, transpulmonary pressures and EELV did not significantly differ despite lower positive end-expiratory pressure and plateau airway pressure, thereby reducing non-normalized and normalized lung elastic static power in PP. PP improved gas exchange, cardiac output, and increased oxygen delivery compared with SP. CONCLUSIONS: In patients with moderate to severe ARDS, PP reduced lung total elastic and elastic static power compared with SP regardless of EELV normalization because comparable transpulmonary pressures and EELV were achieved at lower airway pressures. This resulted in improved gas exchange, hemodynamics, and oxygen delivery. TRIAL REGISTRATION: German Clinical Trials Register (DRKS00017449). Registered June 27, 2019. https://drks.de/search/en/trial/DRKS00017449.


Asunto(s)
Pulmón , Síndrome de Dificultad Respiratoria , Humanos , Estudios Prospectivos , Posición Prona , Síndrome de Dificultad Respiratoria/complicaciones , Oxígeno , Respiración Artificial/efectos adversos , Respiración Artificial/métodos
12.
Ultrasound Obstet Gynecol ; 64(3): 354-361, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39133867

RESUMEN

OBJECTIVE: To assess and compare the value of antenatally determined observed-to-expected (O/E) lung-area-to-head-circumference ratio (LHR) on ultrasound examination vs O/E total fetal lung volume (TFLV) on magnetic resonance imaging (MRI) examination to predict postnatal survival of fetuses with isolated, expectantly managed left-sided congenital diaphragmatic hernia (CDH). METHODS: This was a multicenter retrospective study including all consecutive fetuses with isolated CDH that were managed expectantly in Mannheim, Germany, and in five other European centers, that underwent at least one ultrasound examination for measurement of O/E-LHR and one MRI scan for measurement of O/E-TFLV during pregnancy. All MRI data were centralized, and lung volumes were measured by two experienced operators blinded to the pre- and postnatal data. Multiple logistic regression analyses were performed to examine the effect on survival at hospital discharge of various perinatal variables, including the center of management. In left-sided CDH with intrathoracic herniation of the liver, receiver-operating-characteristics (ROC) curves were constructed separately for cases from Mannheim and the other five European centers and were used to compare O/E-TFLV and O/E-LHR in the prediction of postnatal survival. RESULTS: From Mannheim, 309 patients were included with a median gestational age (GA) at ultrasound examination of 29.6 (range, 19.7-39.1) weeks and median GA at MRI examination of 31.1 (range, 18.0-39.9) weeks. From the other five European centers, 116 patients were included with a median GA at ultrasound examination of 26.7 (range, 20.6-37.6) weeks and median GA at MRI examination of 27.7 (range, 21.3-37.9) weeks. Regression analysis demonstrated that the survival rates at discharge were lower in left-sided CDH (odds ratio (OR), 0.349 (95% CI, 0.133-0.918), P = 0.033) and those with intrathoracic liver (OR, 0.297 (95% CI, 0.141-0.628), P = 0.001), and higher with increasing O/E-TFLV (OR, 1.123 (95% CI, 1.079-1.170), P < 0.001), advanced GA at birth (OR, 1.294 (95% CI, 1.055-1.588), P = 0.013) and when birth occurred in Mannheim (OR, 7.560 (95% CI, 3.368-16.967), P < 0.001). Given the difference in survival rate between Mannheim and the five other European centers, ROC curve comparisons between the two imaging modalities were presented separately. For cases of left-sided CDH with intrathoracic herniation of the liver, pairwise comparison showed no significant difference between the area under the ROC curves for the prediction of postnatal survival between O/E-TFLV and O/E-LHR in Mannheim (mean difference = 0.025, P = 0.610, standard error = 0.050), whereas there was a significant difference in the other European centers studied (mean difference = 0.056, P = 0.033, standard error = 0.056). CONCLUSIONS: In fetuses with left-sided CDH and intrathoracic herniation of the liver, the predictive value for postnatal survival of O/E-TFLV on MRI examination and O/E-LHR on ultrasound examination was similar in one center (Mannheim), but O/E-TFLV had better predictive value compared to O/E-LHR in the five other European centers. Hence, in these five European centers, MRI should be included in the diagnostic process for left-sided CDH. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Hernias Diafragmáticas Congénitas , Pulmón , Imagen por Resonancia Magnética , Ultrasonografía Prenatal , Humanos , Femenino , Hernias Diafragmáticas Congénitas/diagnóstico por imagen , Hernias Diafragmáticas Congénitas/mortalidad , Hernias Diafragmáticas Congénitas/embriología , Embarazo , Estudios Retrospectivos , Pulmón/diagnóstico por imagen , Pulmón/embriología , Mediciones del Volumen Pulmonar/métodos , Edad Gestacional , Valor Predictivo de las Pruebas , Adulto , Cabeza/diagnóstico por imagen , Cabeza/embriología , Europa (Continente) , Alemania , Recién Nacido
13.
Surg Endosc ; 38(2): 679-687, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38017156

RESUMEN

OBJECTIVES: Lung volume reduction surgery (LVRS) has proven an effective treatment for emphysema, by decreasing hyperinflation and improving lung function, activity level and reducing dyspnoea. However, postoperative air leak is an important complication, often leading to reoperation. Our aim was to analyse reoperations after LVRS and identify potential predictors. METHODS: Consecutive single-centre unilateral VATS LVRS performed from 2017 to 2022 were included. Typically, 3-5 minor resections were made using vascular magazines without buttressing. Data were obtained from an institutional database and analysed. Multivariable logistic regression was used to identify predictors of reoperation. Number and location of injuries were registered. RESULTS: In total, 191 patients were included, 25 were reoperated (13%). In 21 patients, the indication for reoperation was substantial air leak, 3 patients bleeding and 1 patient empyema. Length of stay (LOS) was 21 (11-33) vs. 5 days (3-11), respectively. Only 3 injuries were in the stapler line, 13 within < 2cm and 15 injuries were in another site. Multivariable logistic regression analysis showed that decreasing DLCO increased risk of reoperation, OR 1.1 (1.03, 1.18, P = 0.005). Resections in only one lobe, compared to resections in multiple lobes, were also a risk factor OR 3.10 (1.17, 9.32, P = 0.03). Patients undergoing reoperation had significantly increased 30-day mortality, OR 5.52 (1.03, 26.69, P = 0.02). CONCLUSIONS: Our incidence of reoperation after LVRS was 13% leading to prolonged LOS and increased 30-day mortality. Low DLCO and resections in a single lobe were significant predictors of reoperation. The air leak was usually not localized in the stapler line.


Asunto(s)
Neumonectomía , Enfisema Pulmonar , Humanos , Neumonectomía/efectos adversos , Reoperación , Enfisema Pulmonar/etiología , Enfisema Pulmonar/cirugía , Segunda Cirugía , Resultado del Tratamiento
14.
Respirology ; 29(8): 694-703, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38720189

RESUMEN

BACKGROUND AND OBJECTIVE: Both bronchoscopic lung volume reduction with endobronchial valves (BLVR-EBV) and pulmonary rehabilitation (PR) are effective treatments for improving exercise capacity and patient-reported outcomes in patients with severe Chronic Obstructive Pulmonary Disease (COPD). According to current recommendations, all BLVR-EBV patients should have undergone PR first. Our aim was to study the effects of PR both before and after BLVR-EBV compared to BLVR-EBV alone. METHODS: We included patients with severe COPD who were eligible for BLVR-EBV and PR. Participants were randomized into three groups: PR before BLVR-EBV, PR after BLVR-EBV or BLVR-EBV without PR. The primary outcome was change in constant work rate cycle test (CWRT) endurance time at 6-month follow-up of the PR groups compared to BLVR-EBV alone. Secondary endpoints included changes in 6-minute walking test, daily step count, dyspnoea and health-related quality of life. RESULTS: Ninety-seven participants were included. At 6-month follow-up, there was no difference in change in CWRT endurance time between the PR before BLVR-EBV and BLVR-EBV alone groups (median: 421 [IQR: 44; 1304] vs. 787 [123; 1024] seconds, p = 0.82) or in any of the secondary endpoints, but the PR after BLVR-EBV group exhibited a smaller improvement in CWRT endurance time (median: 107 [IQR: 2; 573], p = 0.04) and health-related quality of life compared to BLVR-EBV alone. CONCLUSION: The addition of PR to BLVR-EBV did not result in increased exercise capacity, daily step count or improved patient-reported outcomes compared to BLVR-EBV alone, neither when PR was administered before BLVR-EBV nor when PR was administered after BLVR-EBV.


Asunto(s)
Broncoscopía , Tolerancia al Ejercicio , Neumonectomía , Enfisema Pulmonar , Calidad de Vida , Humanos , Masculino , Femenino , Broncoscopía/métodos , Neumonectomía/métodos , Anciano , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/rehabilitación , Enfisema Pulmonar/fisiopatología , Persona de Mediana Edad , Resultado del Tratamiento , Prueba de Paso , Enfermedad Pulmonar Obstructiva Crónica/rehabilitación , Enfermedad Pulmonar Obstructiva Crónica/cirugía , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Prótesis e Implantes , Factores de Tiempo , Índice de Severidad de la Enfermedad
15.
Clin Exp Pharmacol Physiol ; 51(1): 10-16, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37806661

RESUMEN

Bronchoscopic lung volume reduction (BLVR) is a feasible, safe, effective and minimally invasive technique to significantly improve the quality of life of advanced severe chronic obstructive pulmonary disease (COPD). In this study, three-dimensional computed tomography (3D-CT) automatic analysis software combined with pulmonary function test (PFT) was used to retrospectively evaluate the postoperative efficacy of BLVR patients. The purpose is to evaluate the improvement of lung function of local lung tissue after operation, maximize the benefits of patients, and facilitate BLVR in the treatment of patients with advanced COPD. All the reported cases of advanced COPD patients treated with BLVR with one-way valve were collected and analysed from 2017 to 2020. Three-dimensional-CT image analysis software system was used to analyse the distribution of low-density areas <950 Hounsfield units in both lungs pre- and post- BLVR. Meanwhile, all patients performed standard PFT pre- and post-operation for retrospective analysis. We reported six patients that underwent unilateral BLVR with 1 to 3 valves according to the range of emphysema. All patients showed a median increase in forced expiratory volume in 1 second (FEV1) of 34%, compared with baseline values. Hyperinflation was reduced by 16.6% (range, 4.9%-47.2%). The volumetric measurements showed a significant reduction in the treated lobe volume among these patients. Meanwhile, the targeted lobe volume changes were inversely correlated with change in FEV1/FEV1% in patients with heterogeneous emphysematous. We confirm that 3D-CT analysis can quantify the changes of lung volume, ventilation and perfusion, to accurately evaluate the distribution and improvement of emphysema and rely less on the observer.


Asunto(s)
Enfisema , Enfermedad Pulmonar Obstructiva Crónica , Enfisema Pulmonar , Humanos , Neumonectomía/efectos adversos , Neumonectomía/métodos , Estudios Retrospectivos , Calidad de Vida , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/etiología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/cirugía , Enfisema/diagnóstico por imagen , Enfisema/cirugía , Enfisema/etiología , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
16.
Respiration ; 103(6): 344-352, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38531338

RESUMEN

INTRODUCTION: Endoscopic lung volume reduction with endobronchial valves has been widely recognized for treating hyperinflation in advanced chronic obstructive pulmonary disease and emphysema patients. The main challenges include the technical complexity of upper lobe implantation and the number of endobronchial valves required. These issues might be addressed by placing larger diameter valves in the lobar bronchus. This study evaluated the feasibility, efficiency, and safety of the new valve PulmValve (model PV-13) in porcine models. METHODS: Six PV-13 valves were bronchoscopically implanted into the caudal lobe bronchus of six healthy pigs. The procedure time, valve deployment, and removability were recorded. Follow-up examinations included blood tests, chest CT scans, and bronchoscopy at 30 min, 14 days, 28 days, and 84 days post-procedure, with necropsy and pathological evaluations after the final follow-up examination. RESULTS: The successful in vivo deployment and removal of PV-13 valves was established, with a median procedure time of 6.5 min. The distal lung volume reduction was evident at 30 min post-operation and was persistently monitored on day 84. No migration or malfunction of any PV-13 valves was detected, but a mild angle deviation was found in 3 cases. Coughing was observed in four pigs within the first 7 days and localized granulation tissue was observed in all pigs. No cases of pneumothorax, diffuse pneumonia, or hemoptysis were detected. CONCLUSIONS: In this study, we report the successful implantation and removal of a new valve PulmValve in a short operation time. Complete lobar atelectasis was induced without device migration, malfunction, or severe complications. Further studies are warranted to evaluate the long-term, sustained effects and potential benefits in human patients.


Asunto(s)
Broncoscopía , Estudios de Factibilidad , Animales , Porcinos , Broncoscopía/métodos , Neumonectomía/métodos , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Diseño de Prótesis , Femenino , Tomografía Computarizada por Rayos X
17.
Respiration ; : 1-5, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39047701

RESUMEN

INTRODUCTION: Bronchoscopic lung volume reduction (BLVR) using endobronchial coil treatment is a widely studied therapeutic option in patients with end-stage chronic obstructive pulmonary disease (COPD) and pulmonary emphysema. However, patient responses were inconsistent, and, from 2020, production discontinuation rendered the treatment unavailable. In the meantime, a next-generation lung tensioning coil (FreeFlow Coil 4; FreeFlow Medical, Inc., Fremont, CA, USA) has been developed by the inventor of the lung volume reduction coil implant technology. This case study presents the first documented successful BLVR using FreeFlow Coils 4. CASE PRESENTATION: A 68-year-old male patient with COPD, classified as Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage 3, and homogenous emphysema with incomplete interlobar fissures was treated using the new developed FreeFlow Coil 4 in both upper lobes. Apart from a suspected coil-associated opacity, no adverse events occurred. At the 18-week follow-up, a significant improvement in lung function and quality of life was observed, as measured by forced expiratory volume in 1 s (+150 mL), residual volume (-0.50 L), 6-min walking distance (+75 m), and the total score of the St. George's Respiratory Questionnaire (SGRQ) (-35 points). CONCLUSION: BLVR with FreeFlow Coils 4 has shown promising outcomes, significantly improving both pulmonary function and quality of life in 1 patient. However, larger studies and randomized controlled trials are imperative to investigate the efficacy and safety profile of the new coil system.

18.
Respiration ; : 1-11, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38870924

RESUMEN

INTRODUCTION: Patients with chronic obstructive pulmonary disease (COPD) and emphysema experience malnutrition and pulmonary cachexia. Endoscopic lung volume reduction (ELVR) with endobronchial valves has not only improved lung function, exercise capacity, and quality of life but also influenced body weight. Only a few data are available on body composition changes after ELVR. METHODS: This single-center prospective study of patients with advanced COPD investigates body composition before and after endoscopic valve treatment using multifrequency bioelectrical impedance analysis (BIA). The following parameters were evaluated in addition to clinical data and routine tests: body weight, body mass index (BMI), basal metabolic rate, total body water, body fat, cell percentage, phase angle, intracellular water (ICW), extracellular water (ECW), extracellular mass (ECM), body cell mass (BCM), lean body mass (ECM + BCM), and fat-free mass index. RESULTS: A total of 23 patients (mean emphysema index 37.2 ± 7.5%, BMI 23.4 ± 4.3 kg/m2) experienced improvements in lung function and exercise capacity with ELVR. Complete lobar atelectasis was achieved in 39.1% of participants. A non-statistically significant increase in body weight and BMI was observed after ELVR (p = 0.111 and p = 0.102). BIA measurement revealed a worsening of phase angle, cell percentage and ECM/BCM and thus of body composition, but without statistical significance. This is mainly due to a statistically significant increase in ECM, ECW, and ICW (all p < 0.001). CONCLUSION: ELVR demonstrated no beneficial changes in body composition, although patients tend to gain weight. A larger cohort is warranted to confirm these findings.

19.
Intern Med J ; 54(6): 871-881, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38247402

RESUMEN

BACKGROUND: Endobronchial valve (EBV) insertion for lung volume reduction is a management option for patients with severe emphysema. One-way valves cause lobar deflation and improve lung function, exercise capacity and quality of life. AIMS: To retrospectively analyse and compare the outcomes of the first 57 patients treated with EBVs between 2015 and 2021 at the Royal Adelaide Hospital to international standards. METHODS: Clinical outcomes of forced expiratory volume in 1 s (FEV1), residual volume (RV), treated lobe volume reduction (TLVR) and 6-min walk distance (6MWD) at 3, 6 and 12 months after valve insertion were reviewed against established minimally clinically important differences (MCIDs). Complications and subjective breathlessness measured by Borg scores were also reviewed. RESULTS: Fifty-seven patients were included. At 12 months, 77.2% achieved TLVR. FEV1 improved by 170 mL (95% confidence interval (CI): 100-250, P < 0.001), 80 mL (95% CI: 10-150, P = 0.019) and 40 mL (95% CI: -60 to 130, P 0.66) at 3, 6 and 12 months respectively. RV improved by -610 mL (95% CI: -330 to -900, P < 0.0001) at 3 months, -640 mL (95% CI: -360 to -920, P < 0.0001) at 6 months and -360 mL (95% CI: -60 to -680, P = 0.017) at 12 months. 6MWD improved by 57.34 m (95% CI: 36.23-78.45, P < 0.0001) and 44.93 m (95% CI: 7.19-82.67, P = 0.02) at 3 and 6 months. Borg score improved by -0.53 (95% CI: 0.11 to -1.2, P = 0.11) and -0.49 (95% CI: 0.17 to -1.15, P = 0.16) at 3 and 6 months. Complication rates aligned with international standards with mucous/infection (26.3%) and pneumothorax (17.5%) as the most common. Subgroup analysis signalled improved outcomes in patients with heterogeneous emphysema. CONCLUSION: Our study represents the first publicly funded Australian analysis of EBVs. The results align with international prospective trials demonstrating improved lung function and exercise capacity. Australians with severe emphysema and gas trapping should be referred to a multidisciplinary centre for consideration of EBVs.


Asunto(s)
Neumonectomía , Enfisema Pulmonar , Humanos , Masculino , Femenino , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/fisiopatología , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Australia , Volumen Espiratorio Forzado , Resultado del Tratamiento , Calidad de Vida , Tolerancia al Ejercicio , Prueba de Paso , Broncoscopía/métodos , Índice de Severidad de la Enfermedad , Prótesis e Implantes
20.
BMC Pulm Med ; 24(1): 86, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355502

RESUMEN

BACKGROUND: The new endobronchial therapy called biological lung volume reduction (BioLVR) involves using a rapid polymerizing sealant to block off the most emphysematous portions of the lungs. The primary mechanism of action is resorption atelectasis, which is then followed by inflammation and remodeling of the airspace. The remodeling process will result in the formation of scars, leading to the contraction of the lung tissue. As a result, a decrease in functional lung volume is anticipated for a period of 6-8 weeks. OBJECTIVE: Assessing the safety and effectiveness of bronchoscopic installation of (fibrinogen and thrombin) in COPD patients with homogeneous emphysema in terms of radiological, physiological, and quality of life outcomes. METHODS: Between December 2017 and December 2019, 40 COPD patients with homogeneous emphysema were studied using a fiber optic bronchoscope while they were awake but sedated. Tanta University Hospitals' chest medicine department collaborated with the diagnostic radiology department of the Faculty of Medicine. RESULTS: All the following parameters were reduced from their initial values: HRCT volumetry, RV/TLC, mMRC dyspnea scale, CAT score, 6MWT, FEV1, and the FEV1/FVC ratio at the first, third, and sixth months from the beginning (p = 0.001). One individual (0.025%) had pneumonia, whereas three individuals had COPD (0.075%). Using fibrin glue produced locally, biological lung volume reduction (Bio LVR) may be an effective treatment for advanced homogenous emphysema. CONCLUSION: By using locally prepared fibrin glue the biologic lung volume reduction (Bio LVR) may be a convenient method to treat advanced homogenous emphysema.


Asunto(s)
Enfisema , Enfisema Pulmonar , Humanos , Neumonectomía/métodos , Trombina , Fibrinógeno , Adhesivo de Tejido de Fibrina/uso terapéutico , Calidad de Vida , Broncoscopía/métodos , Pulmón/diagnóstico por imagen , Resultado del Tratamiento , Volumen Espiratorio Forzado
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA