RESUMEN
Current kidney perfusion protocols are not optimized for addressing the ex vivo physiological and metabolic needs of the kidney. Ex vivo normothermic perfusion may be utilized to distinguish high-risk kidneys to determine suitability for transplantation. Here, we assessed the association of tissue metabolic changes with changes in a kidney injury biomarker and functional parameters in eight deceased donor kidneys deemed unsuitable for transplantation during a 12-hour ex vivo normothermic perfusion. The kidneys were grouped into good and poor performers based on blood flow and urine output. The mean age of the deceased kidney donors was 43 years with an average cold ischemia time of 37 hours. Urine output and creatinine clearance progressively increased and peaked at six hours post-perfusion among good performers. Poor performers had 71 ng/ml greater (95% confidence interval 1.5, 140) urinary neutrophil gelatinase-associated lipocalin at six hours compared to good performers corresponding to peak functional differences. Organ performance was distinguished by tissue metabolic differences in branched chain amino acid metabolism and that their tissue levels negatively correlated with urine output among all kidneys at six hours. Tissue lipid profiling showed poor performers were highlighted by the accumulation of membrane structure components including glycerolipids and sphingolipids at early perfusion time points. Thus, we showed that six hours is needed for kidney function recovery during ex vivo normothermic perfusion and that branched chain amino acid metabolism may be a major determinant of organ function and resilience.
Asunto(s)
Aminoácidos de Cadena Ramificada , Biomarcadores , Trasplante de Riñón , Riñón , Lipocalina 2 , Preservación de Órganos , Perfusión , Donantes de Tejidos , Humanos , Perfusión/métodos , Adulto , Trasplante de Riñón/métodos , Masculino , Riñón/metabolismo , Riñón/irrigación sanguínea , Persona de Mediana Edad , Femenino , Preservación de Órganos/métodos , Aminoácidos de Cadena Ramificada/metabolismo , Biomarcadores/orina , Biomarcadores/metabolismo , Lipocalina 2/orina , Lipocalina 2/metabolismo , Factores de Tiempo , Isquemia Fría/efectos adversos , Selección de Donante/métodos , Creatinina/sangre , Creatinina/orinaRESUMEN
As an alternative to static cold storage (SCS), advanced perfusion techniques such as normothermic regional perfusion and ex-situ perfusion (normothermic or hypothermic) have emerged as a way to improve the ischemic injury suffered by donation after circulatory death (DCD) livers. Multiple studies have been published that have demonstrated superior post-DCD liver transplant outcomes when using advanced perfusion compared with SCS. In particular, these studies have shown lower rates of ischemic cholangiopathy with advanced perfusion. In addition to the improved post-liver transplant outcomes, studies have also demonstrated higher rates of liver utilization from DCD donors when advanced perfusion is used compared with SCS. Given the high rates of graft loss in patients who develop ischemic cholangiopathy, the significant reduction seen in DCD donor livers that have undergone advanced perfusion represents a key step in more broad utilization of these livers. With such compelling evidence from multiple trials, it seems reasonable to ask the question: should advanced perfusion be the standard of care for DCD liver transplant?
Asunto(s)
Trasplante de Hígado , Preservación de Órganos , Perfusión , Donantes de Tejidos , Obtención de Tejidos y Órganos , Humanos , Preservación de Órganos/métodos , Perfusión/métodos , Nivel de Atención , Obtención de Tejidos y Órganos/normas , Obtención de Tejidos y Órganos/métodos , Donantes de Tejidos/provisión & distribuciónRESUMEN
BACKGROUND: The Organ Care System (OCS) (Transmedics, Andover, MA) reduces cold ischemic time of donor hearts by producing a normothermic beating state during ex vivo perfusion, enabling extended ex situ intervals, which potentially increases donor pool. We aimed to compare outcomes in utilization of OCS and conventional cold storage technique. METHODS: Consecutive heart transplants following brain death at our institution between May 2022 and July 2023 were analyzed. Recipients were divided into those receiving hearts preserved with OCS [N = 15] and those with conventional cold storage (Control, N = 27), with OCS utilization when anticipated ischemic time was more than 4 h. Pre-transplant characteristics and transplant outcomes were compared. RESULTS: OCS utilization allowed a significant increase in distance traveled for heart retrieval (OCS, 624 ± 269 vs. Control, 153 ± 128 miles, p < 0.001), with longer mean total preservation times (6.2 ± 1.1 vs 2.6 ± 0.6 h, p < 0.001). All but one patient displayed a general decrease or plateau in lactate throughout perfusion time by OCS. Both groups experienced similar rates of severe primary graft dysfunction (OCS, 6.7% [N = 1] vs. Control, 11.1% [N = 3], p = 0.63), with 100% in-hospital survival in the OCS group compared to 96.3% in the Control group (p = 0.34). Kaplan-Meier survival analysis showed that estimated one-year survival were comparable (OCS, 93.3 ± 6.4% vs. Control, 88.9 ± 6.0%, p = 0.61). CONCLUSION: With a mean preservation time of around 6 h and distance covered of over 600 miles, our results using OCS indicate a potential to safely increase the quantity and viability of accessible organs, thus broadening the donor pool without negatively affecting outcomes.
RESUMEN
The present study investigated the effects of triiodothyronine (T3) administration in ex vivo model of rat heart normothermic perfusion. T3 is cardioprotective and has the potential to repair the injured myocardium. Isolated hearts were subjected to normothermic perfusion (NP) with Krebs-Henseleit for 4 h with vehicle (NP) or 60 nM T3 in the perfusate (NP + T3). Left ventricular end diastolic pressure (LVEDP), left ventricular developed pressure (LVDP), perfusion pressure (PP) and percentage of change of these parameters from the baseline values were measured. Activation of stress induced kinase signaling was assessed in tissue samples. Baseline parameters were similar between groups. LVEDP was increased from the baseline by 13% (70) for NP + T3 vs. 139% (160) for NP group, p = 0.048. LVDP was reduced by 18.2% (5) for NP + T3 vs. 25.3% (19) for NP group, p = 0.01. PP was increased by 41% (19) for NP + T3 vs.91% (56) for NP group, p = 0.024. T3 increased activation of pro-survival Akt by 1.85 fold (p = 0.047) and AMPK by 2.25 fold (p = 0.01) and reduced activation of pro-apoptotic p38 MAPK by 3fold (p = 0.04) and p54 JNK by 4.0 fold (p = 0.04). Administration of T3 in normothermic perfusion had favorable effects on cardiac function and perfusion pressure and switched death to pro-survival kinase signaling.
Asunto(s)
Trasplante de Corazón , Corazón , Triyodotironina , Animales , Ratas , Corazón/efectos de los fármacos , Miocardio , Perfusión , Donantes de Tejidos , Técnicas In Vitro , Triyodotironina/farmacologíaRESUMEN
Considering recent clinical and experimental evidence, expectations for using DCD-derived intestines have increased considerably. However, more knowledge about DCD procedure and long-term results after intestinal transplantation (ITx) is needed. We aimed to describe in detail a DCD procedure for ITx using normothermic regional perfusion (NRP) in a preclinical model. Small bowel was obtained from pigs donors after 1 h of NRP and transplanted to the recipients. Graft Intestinal samples were obtained during the procedure and after transplantation. Ischemia-reperfusion injury (Park-Chiu score), graft rejection and transplanted intestines absorptive function were evaluated. Seven of 8 DCD procedures with NRP and ITx were successful (87.5%), with a good graft reperfusion and an excellent recovery of the recipient. The architecture of grafts was well conserved during NRP. After an initial damage of Park-chiu score of 4, all grafts recovered from ischemia-reperfusion, with no or very subtle alterations 2 days after ITx. Most recipients (71.5%) did not show signs of rejection. Only two cases demonstrated histologic signs of mild rejection 7 days after ITx. Interestingly intestinal grafts showed good absorptive capacity. The study's results support the viability of intestinal grafts from DCD using NRP, contributing more evidence for the use of DCD for ITx.
Asunto(s)
Daño por Reperfusión , Donantes de Tejidos , Animales , Porcinos , Humanos , Perfusión , Reperfusión , Rechazo de InjertoRESUMEN
PURPOSE: There are no established criteria for discontinuing ex vivo normothermic limb perfusion (EVNLP) before irreversible damage occurs. This study evaluates weight gain as an indicator of injury during EVNLP. METHODS: Sixteen Yorkshire pig forelimbs were procured and preserved using EVNLP with a hemoglobin-based oxygen carrier (HBOC-201) or static cold storage. EVNLP continued until termination criteria were met: arterial pressure ≥ 115 mm Hg, compartment pressure > 30 mm Hg, or 20% reduction of oxygen saturation. Limb weight, contractility, hemodynamics, perfusate electrolytes, metabolites and gases were recorded. Muscles were biopsied 6-h, and muscle injury scores (MIS) calculated. Forearm compartment pressures and indocyanine green (ICG) angiography were recorded at endpoint. Outcomes were compared at 2%, 5%, 10%, and 20% limb weight gain. RESULTS: EVNLP lasted 20 ± 3 h. Weight gain was observed after 13 ± 5 h (2%), 15 ± 6 h (5%), 16 ± 6 h (10%), and 19 ± 4 h (20%). Weight correlated positively with MIS (ρ = 0.92, p < 0.0001), potassium (ρ = -1.00, p < 0.0001), pressure (ρ = 0.78, p < 0.0001), and negatively with contractility (ρ = -0.96, p = 0.011). At 5% weight gain, MIS (p < 0.0001), potassium (p = 0.03), and lactate (p < 0.0001) were significantly higher than baseline. Median muscle contractility was 5 [3-5] at 2% weight gain, 4 [1-5] at 5%, 3 [0-4] and 2 [0-2] at 10% and 20%, respectively. At 20% weight gain, contractility was significantly lower than baseline (p = 0.003). Percent weight gain correlated negatively with endpoint ICG hoof fluorescence (r = -0.712, p = 0.047). CONCLUSIONS: Weight gain correlated with microscopic muscle injury and was the earliest evidence of limb dysfunction. Weight gain may serve as a criterion for discontinuation of EVNLP.
Asunto(s)
Circulación Extracorporea , Extremidades , Animales , Porcinos , Perfusión/efectos adversos , Miembro Anterior , Potasio , Preservación de ÓrganosRESUMEN
BACKGROUND: Ex situliver machine perfusion at subnormothermic/normothermic temperature isincreasingly applied in the field of transplantation to store and evaluateorgans on the machine prior transplantation. Currently, various perfusionconcepts are in clinical and preclinical applications. Over the last 6 years ina multidisciplinary team, a novel blood based perfusion technology wasdeveloped to keep a liver alive and metabolically active outside of the bodyfor at least one week. METHODS: Within thismanuscript, we present and compare three scenarios (Group 1, 2 and 3) we werefacing during our research and development (R&D) process, mainly linked tothe measurement of free hemoglobin and lactate in the blood based perfusate. Apartfrom their proven value in liver viability assessment (ex situ), these twoparameters are also helpful in R&D of a long-term liver perfusion machine and moreover supportive in the biomedical engineering process. RESULTS: Group 1 ("good" liver on the perfusion machine) represents the best liver clearance capacity for lactate and free hemoglobin wehave observed. In contrast to Group 2 ("poor" liver on the perfusion machine), that has shown the worst clearance capacity for free hemoglobin. Astonishingly,also for Group 2, lactate is cleared till the first day of perfusion andafterwards, rising lactate values are detected due to the poor quality of theliver. These two perfusate parametersclearly highlight the impact of the organ quality/viability on the perfusion process. Whereas Group 3 is a perfusion utilizing a blood loop only (without a liver). CONCLUSION: Knowing the feasible ranges (upper- and lower bound) and the courseover time of free hemoglobin and lactate is helpful to evaluate the quality ofthe organ perfusion itself and the maturity of the developed perfusion device. Freehemoglobin in the perfusate is linked to the rate of hemolysis that indicates how optimizing (gentle blood handling, minimizing hemolysis) the perfusion machine actually is. Generally, a reduced lactate clearancecapacity can be an indication for technical problems linked to the blood supplyof the liver and therefore helps to monitor the perfusion experiments.Moreover, the possibility is given to compare, evaluate and optimize developed liverperfusion systems based on the given ranges for these two parameters. Otherresearch groups can compare/quantify their perfusate (blood) parameters withthe ones in this manuscript. The presented data, findings and recommendations willfinally support other researchers in developing their own perfusion machine ormodifying commercially availableperfusion devices according to their needs.
Asunto(s)
Hemólisis , Trasplante de Hígado , Humanos , Preservación de Órganos , Hígado , Perfusión , Lactatos , HemoglobinasRESUMEN
Predicting organ viability before transplantation remains one of the most challenging and ambitious objectives in transplant surgery. Waitlist mortality is high while transplantable organs are discarded. Currently, around 20% of deceased donor kidneys and livers are discarded because of "poor organ quality", Decisions to discard are still mainly a subjective judgement since there are only limited reliable tools predictive of outcome available. Organ perfusion technology has been posed as a platform for pre-transplant organ viability assessment. Markers of graft injury and function as well as perfusion parameters have been investigated as possible viability markers during ex-situ hypothermic and normothermic perfusion. We provide an overview of the available evidence for the use of kidney and liver perfusion as a tool to predict posttransplant outcomes. Although evidence shows post-transplant outcomes can be predicted by both injury markers and perfusion parameters during hypothermic kidney perfusion, the predictive accuracy is too low to warrant clinical decision making based upon these parameters alone. In liver, further evidence on the usefulness of hypothermic perfusion as a predictive tool is needed. Normothermic perfusion, during which the organ remains fully metabolically active, seems a more promising platform for true viability assessment. Although we do not yet fully understand "on-pump" organ behaviour at normothermia, initial data in kidney and liver are promising. Besides the need for well-designed (registry) studies to advance the field, the catch-22 of selection bias in clinical studies needs addressing.
Asunto(s)
Riñón , Preservación de Órganos , Humanos , Hígado , Perfusión , Donantes de TejidosRESUMEN
INTRODUCTION: Recent experimental evidence suggests normothermic machine perfusion of the vascularized composite allograft results in improved preservation compared to static cold storage, with less reperfusion injury in the immediate post-operative period. However, metabolic acidosis is a common feature of vascularized composite allograft perfusion, primarily due to the inability to process metabolic by-products. We evaluated the impact of combined limb-kidney perfusion on markers of metabolic acidosis and inflammation in a porcine model. METHODS: Ten paired pig forelimbs were used for this study, grouped as either limb-only (LO, n = 5) perfusion, or limb-kidney (LK, n = 5) perfusion. Infrared thermal imaging was used to determine homogeneity of perfusion. Lactate, bicarbonate, base, pH, and electrolytes, along with an inflammatory profile generated via the quantification of cytokines and cell-free DNA in the perfusate were recorded. RESULTS: The addition of a kidney to a limb perfusion circuit resulted in the rapid stabilization of lactate, bicarbonate, base, and pH. Conversely, the LO circuit became progressively acidotic, correlating in a significant increase in pro-inflammatory cytokines. Global perfusion across the limb was more homogenous with LK compared to LO. CONCLUSION: The addition of a kidney during limb perfusion results in significant improvements in perfusate biochemistry, with no evidence of metabolic acidosis.
Asunto(s)
Acidosis/prevención & control , Aloinjertos Compuestos , Riñón/fisiología , Perfusión/métodos , Animales , Miembro Anterior , Inflamación/prevención & control , Daño por Reperfusión , Sus scrofaRESUMEN
INTRODUCTION: Organ preservation through ex-vivo normothermic perfusion (EVNP) with albumin-derived perfluorocarbon-based artificial oxygen carriers (A-AOCs) consisting of albumin-derived perfluorodecalin-filled nanocapsules prior to transplantation would be a promising approach to avoid hypoxic tissue injury during organ storage. METHODS: The kidneys of 16 rats underwent EVNP for 2 h with plasma-like solution (5% bovine serum albumin, Ringer-Saline, inulin) with or without A-AOCs in different volume fractions (0%, 2%, 4%, or 8%). Cell death was determined using TdT-mediated dUTP-biotin nick end labeling (TUNEL). Aspartate transaminase (AST) activity in both perfusate and urine as well as the glomerular filtration rate (GFR) were determined. The hypoxia inducible factors 1α and 2α (HIF-1α und -2α) were quantified in tissue homogenates. RESULTS: GFR was substantially decreased in the presence of 0%, 2%, and 8% A-AOC but not of 4%. In accordance, hypoxia-mediated cell death, as indicated by both AST activity and TUNEL-positive cells, was significantly decreased in the 4% group compared to the control group. The stabilization of HIF-1α and 2α decreased with 4% and 8% but not with 2% A-AOCs. CONCLUSION: The dosage of 4% A-AOCs in EVNP was most effective in maintaining the physiological renal function.
Asunto(s)
Trasplante de Riñón , Soluciones Preservantes de Órganos , Albúminas , Animales , Hipoxia , Riñón/fisiología , Preservación de Órganos , Oxígeno , Perfusión , RatasRESUMEN
Understanding how breast cancer (BC) grows in axillary lymph nodes (ALNs), and refining how therapies might halt that process, is clinically important. However, modelling the complex ALN microenvironment is difficult, and no human models exist at present. We harvested ALNs from ten BC patients, and perfused them at 37 °C ex vivo for up to 24 h. Controlled autologous testing showed that ALNs remain viable after 24 h of ex vivo perfusion: haematoxylin and eosin-stained histological appearance and proliferation (by Ki67 immunohistochemistry) did not change significantly over time for any perfused ALN compared with a control from time-point zero. Furthermore, targeted gene expression analysis (NanoString PanCancer IO360 panel) showed that only 21/750 genes were differentially expressed between control and perfused ALNs (|log2 FC| > 1 and q < 0.1): none were involved in apoptosis and metabolism, but rather all 21 genes were involved in immune function and angiogenesis. During perfusion, tissue acid-base balance remained stable. Interestingly, the flow rate increased (p < 0.001) in cancer-replaced (i.e. metastasis occupied more than 90% of the surface area on multiple levels) compared to cancer-free nodes (i.e. nodes with no metastasis on multiple sections). CXCL11 transcripts were significantly more abundant in cancer-replaced nodes, while CXCL12 transcripts were significantly more abundant in cancer-free nodes. These cytokines were also detected in the circulating perfusate. Monoclonal antibodies (nivolumab and trastuzumab) were administered into a further three ALNs to confirm perfusion efficacy. These drugs saturated the nodes; nivolumab even induced cancer cell death. Normothermic ALN perfusion is not only feasible but sustains the tumour microenvironment ex vivo for scientific investigation. This model could facilitate the identification of actionable immuno-oncology targets. © 2019 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of Pathological Society of Great Britain and Ireland.
Asunto(s)
Neoplasias de la Mama/patología , Ganglios Linfáticos/patología , Metástasis Linfática/patología , Estudios de Factibilidad , Femenino , Humanos , Persona de Mediana Edad , PerfusiónRESUMEN
Maintaining organ viability between donation and transplantation is of critical importance for optimal graft function and survival. To date in pancreas transplantation, static cold storage (SCS) is the most widely practiced method of organ preservation. The first experiments in ex vivo perfusion of the pancreas were performed at the beginning of the 20th century. These perfusions led to organ oedema, hemorrhage, and venous congestion after revascularization. Despite these early hurdles, a number of factors now favor the use of perfusion during preservation: the encouraging results of HMP in kidney transplantation, the development of new perfusion solutions, and the development of organ perfusion machines for the lung, heart, kidneys and liver. This has led to a resurgence of research in machine perfusion for whole organ pancreas preservation. This review highlights the ischemia-reperfusion injuries assessment during ex vivo pancreas perfusion, both for assessment in pre-clinical experimental models as well for future use in the clinic. We evaluated perfusion dynamics, oedema assessment, especially by impedance analysis and MRI, whole organ oxygen consumption, tissue oxygen tension, metabolite concentrations in tissue and perfusate, mitochondrial respiration, cell death, especially by histology, total cell free DNA, caspase activation, and exocrine and endocrine assessment.
Asunto(s)
Preservación de Órganos/métodos , Trasplante de Páncreas , Páncreas/fisiología , Daño por Reperfusión/prevención & control , Supervivencia Tisular , Animales , HumanosRESUMEN
Ischemia and reperfusion injury remains a significant limiting factor for the successful revascularization of amputated extremities. Ex vivo normothermic perfusion is a novel approach to prolong the viability of the amputated limbs by maintaining physiologic cellular metabolism. This study aimed to evaluate the outcomes of extended ex vivo normothermic limb perfusion (EVNLP) in preserving the viability of amputated limbs for over 24 hours. A total of 10 porcine forelimbs underwent EVNLP. Limbs were perfused using an oxygenated colloid solution at 38°C containing washed RBCs. Five forelimbs (Group A) were perfused for 12 hours and the following 5 (Group B) until the vascular resistance increased. Contralateral forelimbs in each group were preserved at 4°C as a cold storage control group. Limb viability was compared between the 2 groups through assessment of muscle contractility, compartment pressure, tissue oxygen saturation, indocyanine green (ICG) angiography and thermography. EVNLP was performed for 12 hours in group A and up to 44 hours (24-44 hours) in group B. The final weight increase (-1.28 ± 8.59% vs. 7.28 ± 15.05%, P = .548) and compartment pressure (16.50 ± 8.60 vs. 24.00 ± 9.10) (P = .151) were not significantly different between the two groups. Final myoglobin and CK mean values in group A and B were: 875.0 ± 325.8 ng/mL (A) versus 1133.8 ± 537.7 ng/mL (B) (P = .056) and 53 344.0 ± 16 603.0 U/L versus 64 333.3 ± 32 481.8 U/L (P = .286). Tissue oxygen saturation was stable until the end in both groups. Infra-red thermography and ICG-angiography detected variations of peripheral limb perfusion. Our results suggest that extended normothermic preservation of amputated limbs is feasible and that the outcomes of prolonged EVNLP (>24 hours) are not significantly different from short EVNLP (12 hours).
Asunto(s)
Miembro Anterior/cirugía , Preservación de Órganos/métodos , Aloinjertos/irrigación sanguínea , Amputación Quirúrgica/métodos , Animales , Frío , Miembro Anterior/irrigación sanguínea , Miembro Anterior/trasplante , Monitoreo Fisiológico , Perfusión , Porcinos , Termografía , Factores de TiempoRESUMEN
BACKGROUND: The effects of renal allograft ischemic injury on vascular endothelial function have not been clearly established. The aim of this study was to examine vascular reactivity to acetylcholine (ACh) in kidneys subjected to ischemic injury and reperfusion. METHODS: Porcine kidneys were exposed to different combinations of warm ischemic time (WIT) and cold ischemic time (CIT) as follows: 15 min (n = 7), 60 min (n = 6), 90 min (n = 6), or 120 min (n = 4) WIT + 2 h CIT or 15 min WIT + 16 h CIT (n = 8). Kidneys were reperfused at 38°C for 3 h. After reperfusion, ACh was infused into the circuit to assess endothelium-dependent vascular reactivity. RESULTS: The dose-response relationships between renal blood flow and ACh demonstrated that ACh doses of 10-10 to 10-7 mmol/L caused vasodilatation, whereas doses in the range 10-6 to 10-4 mmol/L led to vasoconstriction. For kidneys exposed to 15-90 min WIT, there was a clear relationship between increasing ischemic injury and reduced vasodilatation to ACh. In contrast, kidneys subjected to 120 min WIT completely lost vasoreactivity. The vasodilatory response to ACh was diminished, but not lost, when CIT was increased from 2 h to 16 h. Peak renal blood flow after ACh infusion correlated with the functional parameters in kidneys with 2 h CIT (P < 0.05). CONCLUSIONS: The loss of renal vascular reactivity after 120 min WIT suggests endothelial dysfunction leading to loss of nitric oxide synthesis/release. Measurement of vasoreactivity to ACh in an isolated organ perfusion system has the potential to be developed as a marker of ischemic renal injury before transplantation.
Asunto(s)
Acetilcolina/administración & dosificación , Endotelio Vascular/efectos de los fármacos , Isquemia/complicaciones , Circulación Renal/efectos de los fármacos , Daño por Reperfusión/diagnóstico , Aloinjertos/irrigación sanguínea , Aloinjertos/efectos de los fármacos , Animales , Isquemia Fría/efectos adversos , Modelos Animales de Enfermedad , Endotelio Vascular/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Isquemia/fisiopatología , Riñón/irrigación sanguínea , Riñón/efectos de los fármacos , Trasplante de Riñón/efectos adversos , Perfusión , Daño por Reperfusión/etiología , Daño por Reperfusión/fisiopatología , Sus scrofa , Vasodilatación/efectos de los fármacos , Isquemia Tibia/efectos adversosRESUMEN
BACKGROUND: The PhysioHeart™ is a mature acute platform, based isolated slaughterhouse hearts and able to validate cardiac devices and techniques in working mode. Despite perfusion, myocardial edema and time-dependent function degradation are reported. Therefore, monitoring several variables is necessary to identify which of these should be controlled to preserve the heart function. This study presents biochemical, electrophysiological and hemodynamic changes in the PhysioHeart™ to understand the pitfalls of ex vivo slaughterhouse heart hemoperfusion. METHODS: Seven porcine hearts were harvested, arrested and revived using the PhysioHeart™. Cardiac output, SaO2, glucose and pH were maintained at physiological levels. Blood analyses were performed hourly and unipolar epicardial electrograms (UEG), pressures and flows were recorded to assess the physiological performance. RESULTS: Normal cardiac performance was attained in terms of mean cardiac output (5.1 ± 1.7 l/min) and pressures but deteriorated over time. Across the experiments, homeostasis was maintained for 171.4 ± 54 min, osmolarity and blood electrolytes increased significantly between 10 and 80%, heart weight increased by 144 ± 41 g, free fatty acids (- 60%), glucose and lactate diminished, ammonia increased by 273 ± 76% and myocardial necrosis and UEG alterations appeared and aggravated. Progressively deteriorating electrophysiological and hemodynamic functions can be explained by reperfusion injury, waste product intoxication (i.e. hyperammonemia), lack of essential nutrients, ion imbalances and cardiac necrosis as a consequence of hepatological and nephrological plasma clearance absence. CONCLUSIONS: The PhysioHeart™ is an acute model, suitable for cardiac device and therapy assessment, which can precede conventional animal studies. However, observations indicate that ex vivo slaughterhouse hearts resemble cardiac physiology of deteriorating hearts in a multi-organ failure situation and signalize the need for plasma clearance during perfusion to attenuate time-dependent function degradation. The presented study therefore provides an in-dept understanding of the sources and reasons causing the cardiac function loss, as a first step for future effort to prolong cardiac perfusion in the PhysioHeart™. These findings could be also of potential interest for other cardiac platforms.
Asunto(s)
Mataderos , Corazón/fisiopatología , Hemodinámica , Preparación de Corazón Aislado , Ensayo de Materiales , Perfusión , Animales , Metabolismo Energético , Modelos Animales , Miocardio/metabolismo , Miocardio/patología , Necrosis , Sus scrofa , Factores de TiempoRESUMEN
Growing enthusiasm around machine perfusion (MP) in clinical liver transplantation (LT) may be the preamble for standardized practice to expand the donors' pool. The present systematic review investigated all the liver transplantations performed using grafts treated with MP. A systematic review of 309 papers was performed. Eventually, 27 articles were enrolled for the study. A total number of 173 cases were reported. Only 12 cohort studies were identified: the remaining ones were case reports or case series. Hypothermic machine perfusion was performed in 102 (59.0%), normothermic machine perfusion in 65 (37.6%), and controlled oxygenated rewarming in the remaining 6 (3.4%) cases. Donor characteristics, evaluation of graft quality, and endpoints were not homogeneous among the studies. Overall, post-LT results were excellent, with 1.2 and 4.0% of patients experienced primary non-function and ischemic-type biliary lesions, respectively. CONCLUSION: Until now, no study exists that addresses the role of MP in selecting liver grafts available for LT. All the published studies mainly focused on the feasibility and safety of this new technology. Further research investigating the selection process of marginal donors is required.
Asunto(s)
Supervivencia de Injerto , Trasplante de Hígado/métodos , Hígado/irrigación sanguínea , Preservación de Órganos/métodos , Perfusión/métodos , Humanos , Donantes de TejidosRESUMEN
Normothermic machine perfusion has enormous potential to improve organ preservation and expand the organ donor pool. It is well established in other organs but not the pancreas, which has especially strict organ acceptance criteria. We established a model of normothermic hemoperfusion of the porcine pancreas with and without addition of the kidney as a dialysis organ. Four pancreases were harvested and perfused for 120 min with autologous whole blood at body temperature, two with parallel perfusion of the kidney and two without. The organs and perfusion circuit were evaluated for gross appearance, pH, histology and perfusion parameters. The organs maintained steadily increasing flow rate and perfusion pressure. Gross appearance of the organs was stable but appeared grossly ischemic toward the end of the perfusion period. Histology demonstrated necrosis centered in acinar tissue but islet cells were preserved. pH was significantly alkalotic toward the end of the perfusion, likely due to pancreatic tissue damage. Addition of the kidney did not result in significant improvement of the acid-base environment in this small series. In conclusion, normothermic perfusion of the pancreas is still in the experimental stages but holds great potential. Further studies to optimize perfusion parameters will significantly improve results. Parallel perfusion of the kidney may facilitate improvement in the acid-base environment.
Asunto(s)
Riñón/irrigación sanguínea , Riñón/ultraestructura , Preservación de Órganos/métodos , Páncreas/irrigación sanguínea , Páncreas/ultraestructura , Perfusión/métodos , Animales , Circulación Sanguínea , Temperatura Corporal , Concentración de Iones de Hidrógeno , Isquemia/etiología , Isquemia/patología , Riñón/química , Riñón/patología , Necrosis/etiología , Necrosis/patología , Preservación de Órganos/efectos adversos , Páncreas/química , Páncreas/patología , Perfusión/efectos adversos , Porcinos , TemperaturaRESUMEN
Kidney transplantation is limited by hypothermic preservation techniques. Prolonged periods of cold ischaemia increase the risk of early graft dysfunction and reduce long-term survival. To extend the boundaries of transplantation and utilize kidneys from more marginal donors, improved methods of preservation are required. Normothermic perfusion restores energy levels in the kidney allowing renal function to be restored ex vivo. This has several advantages: cold ischaemic injury can be avoided or minimized, the kidney can be maintained in a stable state allowing close observation and assessment of viability and lastly, it provides the ideal opportunity to add therapies to directly manipulate and improve the condition of the kidney. This review explores the experimental and clinical evidence for ex vivo normothermic perfusion in kidney transplantation and its role in conditioning and repair.
Asunto(s)
Trasplante de Riñón/métodos , Riñón/fisiología , Preservación de Órganos/métodos , Perfusión/métodos , Isquemia Fría , Selección de Donante , Terapia Genética , Humanos , Isquemia/patología , Trasplante de Riñón/instrumentación , Preservación de Órganos/instrumentación , Soluciones Preservantes de Órganos , Perfusión/instrumentación , Trasplante de Células Madre , Temperatura , Donantes de Tejidos , Acondicionamiento PretrasplanteRESUMEN
The increasing difference between the number of patients in waiting lists for liver transplantation and the number of available donors has generated a great interest in the use of non-ideal organs, like grafts obtained from cardiac death donors (DCD). However, the extreme sensibility to ischemia of these livers results in a low utilization rate and a high percentage of post-transplant complications and re-transplantation. Normothermic perfusion machines (NMP) emerged as an alternative that tries to maintain the viability of the organ and even to improve its function. This review focuses on current results of DCD liver transplantation and on the role that NMP may have in this field.
Asunto(s)
Paro Cardíaco , Trasplante de Hígado , Perfusión/instrumentación , Obtención de Tejidos y Órganos/métodos , Humanos , TemperaturaRESUMEN
A short period of ex vivo normothermic perfusion (EVNP) immediately before transplantation can revive the kidney and reduce the effects of cold ischemic (CI) injury. Herein, we report a clinical case of EVNP carried out at an intermediate period of the preservation interval. The kidney was retrieved from a 63-year-old extended criteria donor. After 10 h 29 min of CI the kidney underwent EVNP with 1 unit of compatible packed red blood cells mixed with a priming solution at 35.0°C while the recipient was being prepared for surgery. The mean renal blood flow was 93.6 mL/min/100 g and the kidney produced 60 mL of urine. Shortly after the start of surgery the first intended recipient became unfit for transplantation. After 60 min EVNP the kidney was flushed with cold preservation solution and re-packed in ice. The second period of CI was 5 h and 21 min. The kidney was transplanted without any complications into a 54-year-old predialysis patient. The recipient had immediate graft function with serum creatinine levels falling from 315 to 105 µmol/L by day 7. This is the first report of an intermediate period of EVNP in clinical renal transplantation. This case demonstrates the feasibility and safety of the technique.