Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.091
Filtrar
Más filtros

Intervalo de año de publicación
1.
Strahlenther Onkol ; 200(1): 71-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37380796

RESUMEN

PURPOSE: The robustness of surface-guided (SG) deep-inspiration breath-hold (DIBH) radiotherapy (RT) for left breast cancer was evaluated by investigating any potential dosimetric effects due to the residual intrafractional motion allowed by the selected beam gating thresholds. The potential reduction of DIBH benefits in terms of organs at risk (OARs) sparing and target coverage was evaluated for conformational (3DCRT) and intensity-modulated radiation therapy (IMRT) techniques. METHODS: A total of 192 fractions of SGRT DIBH left breast 3DCRT treatment for 12 patients were analyzed. For each fraction, the average of the real-time displacement between the isocenter on the daily reference surface and on the live surface ("SGRT shift") during beam-on was evaluated and applied to the original plan isocenter. The dose distribution for the treatment beams with the new isocenter point was then calculated and the total plan dose distribution was obtained by summing the estimated perturbed dose for each fraction. Then, for each patient, the original plan and the perturbed one were compared by means of Wilcoxon test for target coverage and OAR dose-volume histogram (DVH) metrics. A global plan quality score was calculated to assess the overall plan robustness against intrafractional motion of both 3DCRT and IMRT techniques. RESULTS: Target coverage and OAR DVH metrics did not show significant variations between the original and the perturbed plan for the IMRT techniques. 3DCRT plans showed significant variations for the left descending coronary artery (LAD) and the humerus only. However, none of the dose metrics exceeded the mandatory dose constraints for any of the analyzed plans. The global plan quality analysis indicated that both 3DCRT and IMRT techniques were affected by the isocenter shifts in the same way and, generally, the residual isocenter shifts more likely tend to worsen the plan in all cases. CONCLUSION: The DIBH technique proved to be robust against residual intrafractional isocenter shifts allowed by the selected SGRT beam-hold thresholds. Small-volume OARs located near high dose gradients showed significant marginal deteriorations in the perturbed plans with the 3DCRT technique only. Global plan quality was mainly influenced by patient anatomy and treatment beam geometry rather than the technique adopted.


Asunto(s)
Neoplasias de la Mama , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Neoplasias de Mama Unilaterales , Humanos , Femenino , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Contencion de la Respiración , Radioterapia Conformacional/métodos , Neoplasias de la Mama/radioterapia , Radioterapia de Intensidad Modulada/métodos , Órganos en Riesgo , Neoplasias de Mama Unilaterales/radioterapia
2.
Strahlenther Onkol ; 200(7): 624-632, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38315236

RESUMEN

BACKGROUND: Radiotherapy is one of the main treatment options for patients with esophageal cancer; however, it has been linked with an increased risk of cardiac toxicities. In the current study, we evaluated the effect of planning the radiation in deep-inspiration breath hold (DIBH) on the dose sparing of cardiac substructures and lung. MATERIALS AND METHODS: In this study, we analyzed 30 radiation therapy plans from 15 patients diagnosed with esophageal cancer planned for neoadjuvant radiotherapy. Radiation plans were generated for 41.4 Gy and delivered in 1.8 Gy per fraction for free-breathing (FB) and DIBH techniques. We then conducted a comparative dosimetric analysis, evaluating target volume coverage, the impact on cardiac substructures, and lung doses across the two planning techniques for each patient. RESULTS: There was no significant disparity in target volume dose coverage between DIBH and FB plans. However, the Dmean, D2%, and V30% of the heart experienced substantial reductions in DIBH relative to FB, with values of 6.21 versus 7.02 Gy (p = 0.011), 35.28 versus 35.84 Gy (p = 0.047), and 5% versus 5.8% (p = 0.048), respectively. The Dmean of the left ventricle was notably lower in DIBH compared to FB (4.27 vs. 5.12 Gy, p = 0.0018), accompanied by significant improvements in V10. Additionally, the Dmean and D2% of the left coronary artery, as well as the D2% of the right coronary artery, were significantly lower in DIBH. The dosimetric impact of DIBH on cardiac substructures proved more advantageous for middle esophageal (ME) than distal esophageal (DE) tumors. CONCLUSION: Radiotherapy in DIBH could provide a method to reduce the radiation dose to the left ventricle and coronaries, which could reduce the cardiac toxicity of the modality.


Asunto(s)
Contencion de la Respiración , Neoplasias Esofágicas , Corazón , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Neoplasias Esofágicas/radioterapia , Masculino , Femenino , Corazón/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Anciano , Traumatismos por Radiación/prevención & control , Traumatismos por Radiación/etiología , Terapia Neoadyuvante , Radiometría
3.
Acta Oncol ; 63: 477-481, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899395

RESUMEN

BACKGROUND: Deep learning (DL) models for auto-segmentation in radiotherapy have been extensively studied in retrospective and pilot settings. However, these studies might not reflect the clinical setting. This study compares the use of a clinically implemented in-house trained DL segmentation model for breast cancer to a previously performed pilot study to assess possible differences in performance or acceptability. MATERIAL AND METHODS: Sixty patients with whole breast radiotherapy, with or without an indication for locoregional radiotherapy were included. Structures were qualitatively scored by radiotherapy technologists and radiation oncologists. Quantitative evaluation was performed using dice-similarity coefficient (DSC), 95th percentile of Hausdorff Distance (95%HD) and surface DSC (sDSC), and time needed for generating, checking, and correcting structures was measured. RESULTS: Ninety-three percent of all contours in clinic were scored as clinically acceptable or usable as a starting point, comparable to 92% achieved in the pilot study. Compared to the pilot study, no significant changes in time reduction were achieved for organs at risks (OARs). For target volumes, significantly more time was needed compared to the pilot study for patients including lymph node levels 1-4, although time reduction was still 33% compared to manual segmentation. Almost all contours have better DSC and 95%HD than inter-observer variations. Only CTVn4 scored worse for both metrics, and the thyroid had a higher 95%HD value. INTERPRETATION: The use of the DL model in clinical practice is comparable to the pilot study, showing high acceptability rates and time reduction.


Asunto(s)
Neoplasias de la Mama , Aprendizaje Profundo , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador , Humanos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/patología , Femenino , Proyectos Piloto , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Estudios Retrospectivos , Persona de Mediana Edad
4.
Acta Oncol ; 63: 448-455, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899392

RESUMEN

BACKGROUND: Robust optimization has been suggested as an approach to reduce the irradiated volume in lung Stereotactic Body Radiation Therapy (SBRT). We performed a retrospective planning study to investigate the potential benefits over Planning Target Volume (PTV)-based planning. MATERIAL AND METHODS: Thirty-nine patients had additional plans using robust optimization with 5-mm isocenter shifts of the Gross Tumor Volume (GTV) created in addition to the PTV-based plan used for treatment. The optimization included the mid-position phase and the extreme breathing phases of the 4D-CT planning scan. The plans were compared for tumor coverage, isodose volumes, and doses to Organs At Risk (OAR). Additionally, we evaluated both plans with respect to observed tumor motion using the peak tumor motion seen on the planning scan and cone-beam CTs. RESULTS: Statistically significant reductions in irradiated isodose volumes and doses to OAR were achieved with robust optimization, while preserving tumor dose. The reductions were largest for the low-dose volumes and reductions up to 188 ccm was observed. The robust evaluation based on observed peak tumor motion showed comparable target doses between the two planning methods. Accumulated mean GTV-dose was increased by a median of 4.46 Gy and a non-significant increase of 100 Monitor Units (MU) was seen in the robust optimized plans. INTERPRETATION: The robust plans required more time to prepare, and while it might not be a feasible planning strategy for all lung SBRT patients, we suggest it might be useful for selected patients.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Órganos en Riesgo , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral , Humanos , Radiocirugia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Órganos en Riesgo/efectos de la radiación , Tomografía Computarizada Cuatridimensional/métodos , Tomografía Computarizada de Haz Cónico , Masculino , Fotones/uso terapéutico , Femenino , Anciano
5.
Acta Oncol ; 63: 56-61, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38404218

RESUMEN

BACKGROUND AND PURPOSE: Proton therapy for breast cancer is usually given in free breathing (FB). With the use of deep inspiration breath-hold (DIBH) technique, the location of the heart is displaced inferiorly, away from the internal mammary nodes and, thus, the dose to the heart can potentially be reduced. The aim of this study was to explore the potential benefit of proton therapy in DIBH compared to FB for highly selected patients to reduce exposure of the heart and other organs at risk. We aimed at creating proton plans with delivery times feasible with treatment in DIBH. MATERIAL AND METHODS: Sixteen patients with left-sided breast cancer receiving loco-regional proton therapy were included. The FB and DIBH plans were created for each patient using spot-scanning proton therapy with 2-3 fields, robust and single field optimization. For the DIBH plans, minimum monitor unit per spot and spot spacing were increased to reduce treatment delivery time. RESULTS: All plans complied with target coverage constraints. The median mean heart dose was statistically significant reduced from 1.1 to 0.6 Gy relative biological effectiveness (RBE) by applying DIBH. No statistical significant difference was seen for mean dose and V17Gy RBE to the ipsilateral lung. The median treatment delivery time for the DIBH plans was reduced by 27% compared to the FB plans without compromising the plan quality. INTERPRETATION: The median absolute reduction in dose to the heart was limited. Proton treatment in DIBH may only be relevant for a subset of these patients with the largest reduction in heart exposure.


Asunto(s)
Neoplasias de la Mama , Terapia de Protones , Traumatismos por Radiación , Neoplasias de Mama Unilaterales , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Protones , Dosificación Radioterapéutica , Contencion de la Respiración , Planificación de la Radioterapia Asistida por Computador/métodos , Corazón , Neoplasias de Mama Unilaterales/radioterapia , Órganos en Riesgo
6.
Acta Oncol ; 63: 240-247, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38682458

RESUMEN

BACKGROUND AND PURPOSE: Doses to the coronary arteries in breast cancer (BC) radiotherapy (RT) have been suggested to be a risk predictor of long-term cardiac toxicity after BC treatment. We investigated the dose-risk relationships between near maximum doses (Dmax) to the right coronary artery (RCA) and left anterior descending coronary artery (LAD) and ischemic heart disease (IHD) mortality after BC RT. PATIENTS AND METHODS: In a cohort of 2,813 women diagnosed with BC between 1958 and 1992 with a follow-up of at least 10 years, we identified 134 cases of death due to IHD 10-19 years after BC diagnosis. For each case, one control was selected within the cohort matched for age at diagnosis. 3D-volume and 3D-dose reconstructions were obtained from individual RT charts. We estimated the Dmax to the RCA and the LAD and the mean heart dose (MHD). We performed conditional logistic regression analysis comparing piecewise spline transformation and simple linear modeling for best fit. RESULTS: There was a linear dose-risk relationship for both the Dmax to the RCA (odds ratio [OR]/Gray [Gy] 1.03 [1.01-1.05]) and the LAD (OR/Gy 1.04 [1.02-1.06]) in a multivariable model. For MHD there was a linear dose-risk relationship (1,14 OR/Gy [1.08-1.19]. For all relationships, simple linear modelling was superior to spline transformations. INTERPRETATION: Doses to both the RCA and LAD are independent risk predictors of long-term cardiotoxicity after RT for BC In addition to the LAD, the RCA should be regarded as an organ at risk in RT planning.


Asunto(s)
Neoplasias de la Mama , Vasos Coronarios , Isquemia Miocárdica , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/mortalidad , Estudios de Casos y Controles , Persona de Mediana Edad , Vasos Coronarios/efectos de la radiación , Vasos Coronarios/patología , Isquemia Miocárdica/etiología , Isquemia Miocárdica/mortalidad , Anciano , Adulto , Traumatismos por Radiación/etiología , Traumatismos por Radiación/epidemiología , Traumatismos por Radiación/mortalidad , Dosificación Radioterapéutica , Relación Dosis-Respuesta en la Radiación , Órganos en Riesgo/efectos de la radiación , Estudios de Seguimiento , Estudios de Cohortes
7.
World J Surg Oncol ; 22(1): 147, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38831328

RESUMEN

BACKGROUND: Radio(chemo)therapy is often required in pelvic malignancies (cancer of the anus, rectum, cervix). Direct irradiation adversely affects ovarian and endometrial function, compromising the fertility of women. While ovarian transposition is an established method to move the ovaries away from the radiation field, surgical procedures to displace the uterus are investigational. This study demonstrates the surgical options for uterine displacement in relation to the radiation dose received.  METHODS: The uterine displacement techniques were carried out sequentially in a human female cadaver to demonstrate each procedure step by step and assess the uterine positions with dosimetric CT scans in a hybrid operating room. Two treatment plans (anal and rectal cancer) were simulated on each of the four dosimetric scans (1. anatomical position, 2. uterine suspension of the round ligaments to the abdominal wall 3. ventrofixation of the uterine fundus at the umbilical level, 4. uterine transposition). Treatments were planned on Eclipse® System (Varian Medical Systems®,USA) using Volumetric Modulated Arc Therapy. Data about maximum (Dmax) and mean (Dmean) radiation dose received and the volume receiving 14 Gy (V14Gy) were collected. RESULTS: All procedures were completed without technical complications. In the rectal cancer simulation with delivery of 50 Gy to the tumor, Dmax, Dmean and V14Gy to the uterus were respectively 52,8 Gy, 34,3 Gy and 30,5cc (1), 31,8 Gy, 20,2 Gy and 22.0cc (2), 24,4 Gy, 6,8 Gy and 5,5cc (3), 1,8 Gy, 0,6 Gy and 0,0cc (4). For anal cancer, delivering 64 Gy to the tumor respectively 46,7 Gy, 34,8 Gy and 31,3cc (1), 34,3 Gy, 20,0 Gy and 21,5cc (2), 21,8 Gy, 5,9 Gy and 2,6cc (3), 1,4 Gy, 0,7 Gy and 0,0cc (4). CONCLUSIONS: The feasibility of several uterine displacement procedures was safely demonstrated. Increasing distance to the radiation field requires more complex surgical interventions to minimize radiation exposure. Surgical strategy needs to be tailored to the multidisciplinary treatment plan, and uterine transposition is the most technically complex with the least dose received.


Asunto(s)
Cadáver , Preservación de la Fertilidad , Neoplasias Pélvicas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Útero , Humanos , Femenino , Planificación de la Radioterapia Asistida por Computador/métodos , Preservación de la Fertilidad/métodos , Útero/efectos de la radiación , Útero/cirugía , Útero/patología , Neoplasias Pélvicas/radioterapia , Neoplasias Pélvicas/cirugía , Neoplasias Pélvicas/patología , Radioterapia de Intensidad Modulada/métodos , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo/efectos de la radiación , Pronóstico , Radiometría/métodos
8.
Radiat Environ Biophys ; 63(1): 47-57, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38194100

RESUMEN

To compare treatment planning and dosimetric outcomes for hippocampal sparing whole brain radiotherapy (WBRT) with the simultaneous integrated boost (SIB) in brain metastasis (BM) patients using tumour control probability (TCP) and normal tissue complication probability (NTCP) formalism between IMRT, VMAT, and HT techniques. In this retrospective study, the treatment data of 20 BM patients who typically received whole brain radiation with SIB treatment were used. Prescription doses of 30 Gy and 36 Gy was delivered in 10 fractions for WBRT and SIB, respectively. Niemierko and LKB models were applied for calculating TCP and NTCP. All the plans were evaluated for the RTOG 0933 protocol criteria and found acceptable. Additionally, the homogeneity of the PTV boost is 0.07 ± 0.01, 0.1 ± 0.04, and 0.08 ± 0.02 for IMRT, VMAT, and HT, respectively (P < 0.05). The percentage of TCP for the PTV boost was 99.99 ± 0.003, 99.98 ± 0.004, and 99.99 ± 0.002 of IMRT, VMAT, and HT, respectively, (P < 0.005). The NTCP value of the lenses was higher with the VMAT plan as compared to IMRT and HT Plans. The hippocampal NTCP values are equal in all three planning proficiencies. The techniques like IMRT, VMAT, and HT can reduce the dose received by hippocampus to the dosimetric threshold during the delivery of WBRT with hippocampal sparing and can simultaneously boost multiple metastases. Overall, the high-quality dose distribution, TCP, and NTCP comparison between all three planning techniques show that the HT technique has better results when compared to the VMAT and IMRT techniques.


Asunto(s)
Neoplasias Encefálicas , Radioterapia de Intensidad Modulada , Humanos , Estudios Retrospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Encéfalo , Hipocampo , Órganos en Riesgo
9.
Radiat Environ Biophys ; 63(2): 297-306, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38722389

RESUMEN

For locally advanced cervical cancer, the standard therapeutic approach involves concomitant chemoradiation therapy, supplemented by a brachytherapy boost. Moreover, an external beam radiotherapy (RT) boost should be considered for treating gross lymph node (LN) volumes. Two boost approaches exist with Volumetric Intensity Modulated Arc Therapy (VMAT): Sequential (SEQ) and Simultaneous Integrated Boost (SIB). This study undertakes a comprehensive dosimetric and radiobiological comparison between these two boost strategies. The study encompassed ten patients who underwent RT for cervical cancer with node-positive disease. Two sets of treatment plans were generated for each patient: SIB-VMAT and SEQ-VMAT. Dosimetric as well as radiobiological parameters including tumour control probability (TCP) and normal tissue complication probability (NTCP) were compared. Both techniques were analyzed for two different levels of LN involvement - only pelvic LNs and pelvic with para-aortic LNs. Statistical analysis was performed using SPSS software version 25.0. SIB-VMAT exhibited superior target coverage, yielding improved doses to the planning target volume (PTV) and gross tumour volume (GTV). Notably, SIB-VMAT plans displayed markedly superior dose conformity. While SEQ-VMAT displayed favorable organ sparing for femoral heads, SIB-VMAT appeared as the more efficient approach for mitigating bladder and bowel doses. TCP was significantly higher with SIB-VMAT, suggesting a higher likelihood of successful tumour control. Conversely, no statistically significant difference in NTCP was observed between the two techniques. This study's findings underscore the advantages of SIB-VMAT over SEQ-VMAT in terms of improved target coverage, dose conformity, and tumour control probability. In particular, SIB-VMAT demonstrated potential benefits for cases involving para-aortic nodes. It is concluded that SIB-VMAT should be the preferred approach in all cases of locally advanced cervical cancer.


Asunto(s)
Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Neoplasias del Cuello Uterino , Humanos , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/patología , Femenino , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Metástasis Linfática/radioterapia
10.
J Appl Clin Med Phys ; 25(5): e14366, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38669190

RESUMEN

PURPOSE: Skin collimation is a useful tool in electron beam therapy (EBT) to decrease the penumbra at the field edge and minimize dose to nearby superficial organs at risk (OARs), but manually fabricating these collimation devices in the clinic to conform to the patient's anatomy can be a difficult and time intensive process. This work compares two types of patient-specific skin collimation (in-house 3D printed and vendor-provided machined brass) using clinically relevant metrics. METHODS: Attenuation measurements were performed to determine the thickness of each material needed to adequately shield both 6 and 9 MeV electron beams. Relative and absolute dose planes at various depths were measured using radiochromic film to compare the surface dose, flatness, and penumbra of the different skin collimation materials. RESULTS: Clinically acceptable thicknesses of each material were determined for both 6 and 9 MeV electron beams. Field width, flatness, and penumbra results between the two systems were very similar and significantly improved compared to measurements performed with no surface collimation. CONCLUSION: Both skin collimation methods investigated in this work generate sharp penumbras at the field edge and can minimize dose to superficial OARs compared to treatment fields with no surface collimation. The benefits of skin collimation are greatest for lower energy electron beams, and the benefits decrease as the measurement depth increases. Using bolus with skin collimation is recommended to avoid surface dose enhancement seen with collimators placed on the skin surface. Ultimately, the appropriate choice of material will depend on the desire to create these devices in-house or outsource the fabrication to a vendor.


Asunto(s)
Electrones , Órganos en Riesgo , Impresión Tridimensional , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Piel , Humanos , Electrones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Piel/efectos de la radiación , Fantasmas de Imagen , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación
11.
J Appl Clin Med Phys ; 25(1): e14207, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37985962

RESUMEN

PURPOSE: To study the dosimetric impact of incorporating variable relative biological effectiveness (RBE) of protons in optimizing intensity-modulated proton therapy (IMPT) treatment plans and to compare it with conventional constant RBE optimization and linear energy transfer (LET)-based optimization. METHODS: This study included 10 pediatric ependymoma patients with challenging anatomical features for treatment planning. Four plans were generated for each patient according to different optimization strategies: (1) constant RBE optimization (ConstRBEopt) considering standard-of-care dose requirements; (2) LET optimization (LETopt) using a composite cost function simultaneously optimizing dose-averaged LET (LETd ) and dose; (3) variable RBE optimization (VarRBEopt) using a recent phenomenological RBE model developed by McNamara et al.; and (4) hybrid RBE optimization (hRBEopt) assuming constant RBE for the target and variable RBE for organs at risk. By normalizing each plan to obtain the same target coverage in either constant or variable RBE, we compared dose, LETd , LET-weighted dose, and equivalent uniform dose between the different optimization approaches. RESULTS: We found that the LETopt plans consistently achieved increased LET in tumor targets and similar or decreased LET in critical organs compared to other plans. On average, the VarRBEopt plans achieved lower mean and maximum doses with both constant and variable RBE in the brainstem and spinal cord for all 10 patients. To compensate for the underdosing of targets with 1.1 RBE for the VarRBEopt plans, the hRBEopt plans achieved higher physical dose in targets and reduced mean and especially maximum variable RBE doses compared to the ConstRBEopt and LETopt plans. CONCLUSION: We demonstrated the feasibility of directly incorporating variable RBE models in IMPT optimization. A hybrid RBE optimization strategy showed potential for clinical implementation by maintaining all current dose limits and reducing the incidence of high RBE in critical normal tissues in ependymoma patients.


Asunto(s)
Ependimoma , Terapia de Protones , Niño , Humanos , Dosificación Radioterapéutica , Efectividad Biológica Relativa , Transferencia Lineal de Energía , Ependimoma/radioterapia , Planificación de la Radioterapia Asistida por Computador , Órganos en Riesgo
12.
J Appl Clin Med Phys ; 25(3): e14202, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37942993

RESUMEN

Quality of organ at risk (OAR) autosegmentation is often judged by concordance metrics against the human-generated gold standard. However, the ultimate goal is the ability to use unedited autosegmented OARs in treatment planning, while maintaining the plan quality. We tested this approach with head and neck (HN) OARs generated by a prototype deep-learning (DL) model on patients previously treated for oropharyngeal and laryngeal cancer. Forty patients were selected, with all structures delineated by an experienced physician. For each patient, a set of 13 OARs were generated by the DL model. Each patient was re-planned based on original targets and unedited DL-produced OARs. The new dose distributions were then applied back to the manually delineated structures. The target coverage was evaluated with inhomogeneity index (II) and the relative volume of regret. For the OARs, Dice similarity coefficient (DSC) of areas under the DVH curves, individual DVH objectives, and composite continuous plan quality metric (PQM) were compared. The nearly identical primary target coverage for the original and re-generated plans was achieved, with the same II and relative volume of regret values. The average DSC of the areas under the corresponding pairs of DVH curves was 0.97 ± 0.06. The number of critical DVH points which met the clinical objectives with the dose optimized on autosegmented structures but failed when evaluated on the manual ones was 5 of 896 (0.6%). The average OAR PQM score with the re-planned dose distributions was essentially the same when evaluated either on the autosegmented or manual OARs. Thus, rigorous HN treatment planning is possible with OARs segmented by a prototype DL algorithm with minimal, if any, manual editing.


Asunto(s)
Aprendizaje Profundo , Neoplasias Laríngeas , Radioterapia de Intensidad Modulada , Humanos , Neoplasias Laríngeas/etiología , Planificación de la Radioterapia Asistida por Computador , Órganos en Riesgo , Radioterapia de Intensidad Modulada/efectos adversos , Dosificación Radioterapéutica
13.
J Appl Clin Med Phys ; 25(2): e14168, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37798910

RESUMEN

PURPOSE: Knowledge-based planning (KBP) aims to automate and standardize treatment planning. New KBP users are faced with many questions: How much does model size matter, and are multiple models needed to accommodate specific physician preferences? In this study, six head-and-neck KBP models were trained to address these questions. METHODS: The six models differed in training size and plan composition: The KBPFull (n = 203 plans), KBP101 (n = 101), KBP50 (n = 50), and KBP25 (n = 25) were trained with plans from two head-and-neck physicians. KBPA and KBPB each contained n = 101 plans from only one physician, respectively. An independent set of 39 patients treated to 6000-7000 cGy by a third physician was re-planned with all KBP models for validation. Standard head-and-neck dosimetric parameters were used to compare resulting plans. KBPFull plans were compared to the clinical plans to evaluate overall model quality. Additionally, clinical and KBPFull plans were presented to another physician for blind review. Dosimetric comparison of KBPFull against KBP101 , KBP50 , and KBP25 investigated the effect of model size. Finally, KBPA versus KBPB tested whether training KBP models on plans from one physician only influences the resulting output. Dosimetric differences were tested for significance using a paired t-test (p < 0.05). RESULTS: Compared to manual plans, KBPFull significantly increased PTV Low D95% and left parotid mean dose but decreased dose cochlea, constrictors, and larynx. The physician preferred the KBPFull plan over the manual plan in 20/39 cases. Dosimetric differences between KBPFull , KBP101 , KBP50 , and KBP25 plans did not exceed 187 cGy on aggregate, except for the cochlea. Further, average differences between KBPA and KBPB were below 110 cGy. CONCLUSIONS: Overall, all models were shown to produce high-quality plans. Differences between model outputs were small compared to the prescription. This indicates only small improvements when increasing model size and minimal influence of the physician when choosing treatment plans for training head-and-neck KBP models.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Bases del Conocimiento , Radiometría , Órganos en Riesgo
14.
J Appl Clin Med Phys ; 25(1): e14218, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38013656

RESUMEN

OBJECTIVE: This study aimed to discuss the dosimetric advantages of helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) technology in hippocampal avoidance whole-brain radiotherapy and provide references for clinical selection of ideal radiotherapy technology. METHODS: A total of 20 patients with hippocampal avoidance whole-brain radiotherapy were chosen randomly. Computed tomography (CT) and MRI scanning images were input into the treatment planning system (TPS). After the CT and enhanced magnetic resonance T1 weighted images were fused and registered, the same radiation therapy physician was invited to outline the tumor target volume. PTV-HS refers to the whole brain subtracted by 5 mm outward expansion of the hippocampus (HP). The prescribed dose was 30 Gy/10 fractions. HT and VMAT plans were designed for each patient in accordance with PTV. Under the premise that the 95% isodose curve covers the PTV, dose-volume histogram was applied to evaluate the PTV, conformal index (CI), heterogeneity index (HI), maximum dose (Dmax), mean dose (Dmean), minimum dose (Dmin) and absorbed doses of organs at risk (OARs) in HT and VMAT plans. Paired t-test was performed to compare the differences between two radiation therapy plans, and p  <  0.05 was considered statistically significant. RESULTS: These two plans had no significant difference in PTV-HS (max, min, and mean). However, the HI and CI of the HT plan were significantly better than those of the VMAT plan, showing statistically significant difference (p < 0.05). The HT plan was significantly superior to the VMAT plan in terms of the Dmax, Dmin, and Dmean of HP, left and right eye lens, left and right eye, and spinal cord, showing statistically significant difference (p < 0.05). The HT plan was also better than the VMAT plan in terms of the Dmax of the left optic nerve. However, the two plans showed no obvious differences in terms of the absorbed doses of the right optic nerve and brainstem, without statistical significance. CONCLUSIONS: Compared with the VMAT plan of hippocampal avoidance, HT technology has significant dosimetric advantages. HT plans significantly decreased the radiation dose and radiation volume of OARs surrounding the target area (e.g., surrounding eye lens and eye, especially hippocampal avoidance area) while increasing the CI and HI of PTV dose in whole brain radiotherapy (WBRT) greatly, thus enabling the decrease in the incidence rate of radioactive nerve function impairment.


Asunto(s)
Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo , Encéfalo , Hipocampo
15.
J Appl Clin Med Phys ; 25(6): e14277, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38243604

RESUMEN

PURPOSE: This study aimed to improve the safety and accuracy of radiotherapy by establishing tolerance (TL) and action (AL) limits for the gamma index in patient-specific quality assurance (PSQA) for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) using SunCHECK software, as per AAPM TG-218 report recommendations. METHODS: The study included 125 patients divided into six groups by treatment regions (H&N, thoracic and pelvic) and techniques (VMAT, IMRT). SunCHECK was used to calculate the gamma passing rate (%GP) and dose error (%DE) for each patient, for the planning target volume and organs at risk (OARs). The TL and AL were then determined for each group according to TG-218 recommendations. We conducted a comprehensive analysis to compare %DE among different groups and examined the relationship between %GP and %DE. RESULTS: The TL and AL of all groups were more stringent than the common standard as defined by the TG218 report. The TL and AL values of the groups differed significantly, and the values for the thoracic groups were lower for both VMAT and IMRT. The %DE of the parameters D95%, D90%, and Dmean in the planning target volume, and Dmean and Dmax in OARs were significantly different. The dose deviation of VMAT was larger than IMRT, especially in the thoracic group. A %GP and %DE correlation analysis showed a strong correlation for the planning target volume, but a weak correlation for the OARs. Additionally, a significant correlation existed between %GP of SunCHECK and Delta4. CONCLUSION: The study established TL and AL values tailored to various anatomical regions and treatment techniques at our institution. Establishing PSQA workflows for VMAT and IMRT offers valuable clinical insights and guidance. We also suggest developing a standard combining clinically relevant metrics with %GP to evaluate PSQA results comprehensively.


Asunto(s)
Órganos en Riesgo , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Radioterapia de Intensidad Modulada/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Garantía de la Calidad de Atención de Salud/normas , Órganos en Riesgo/efectos de la radiación , Programas Informáticos , Rayos gamma , Neoplasias/radioterapia , Guías de Práctica Clínica como Asunto/normas
16.
J Appl Clin Med Phys ; 25(6): e14267, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38259201

RESUMEN

PURPOSE: To propose an efficient collimator angle optimization method by combining island blocking (IB) and parked gap (PG) problem to reduce the radiotherapy dose for normal tissue. The reduction will be done with single-isocenter multi-lesion volumetric modulated arc therapy (VMAT) for the stereotactic body radiation therapy (SBRT) of liver cancer. METHODS: A novel collimator angle optimization algorithm was developed based on the two-dimensional projection of targets on a beam's eye view (BEV) plane as a function of gantry and collimator angle. This optimization algorithm minimized the sum of the combined IB and PG (IB & PG) areas from all gantry angles for each arc. For comparison, two SBRT plans were respectively generated for each of the 20 retrospective liver cancer cases with multiple lesions. One plan was optimized using the IB & PG algorithm, and the other plan was optimized with a previously reported optimization algorithm that only considered the IB area. Plans were then evaluated and compared using typical dosimetric metrics. RESULTS: With the comparable target coverage, IB & PG plans had significantly lower D500cc, D700cc, mean dose (Dmean), and V15 of normal liver tissues when compared to IB plans. The median percent reductions were 3.32% to 5.36%. The D1cc, D5cc, and Dmean for duodenum and small intestine in IB & PG plans were significantly reduced in a range from 7.60% up to 16.03%. Similarly, the median integral dose was reduced by 3.73%. Furthermore, the percentage of normal liver Dmean sparing when IB & PG plans compared to IB plans, was found to be positively correlated (ρ = 0.669, P = 0.001) with the inter-target distance. CONCLUSION: The proposed IB & PG algorithm has been demonstrated to outperform the IB algorithm in almost all normal tissue sparing, and the magnitude of liver sparing was positively correlated with inter-target distance.


Asunto(s)
Algoritmos , Neoplasias Hepáticas , Órganos en Riesgo , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirugía , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Órganos en Riesgo/efectos de la radiación , Estudios Retrospectivos , Pronóstico , Tratamientos Conservadores del Órgano/métodos
17.
J Appl Clin Med Phys ; 25(6): e14292, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38286001

RESUMEN

BACKGROUND: To determine whether a dual-isocenter volumetrically modulated arc therapy (VMAT) technique results in lower normal pulmonary dosage compared to a traditional single isocenter technique for boot-shaped lung cancer. METHODS: A cohort of 15 patients with advanced peripheral or central lung cancer who had metastases in the mediastinum and supraclavicular lymph nodes was randomly selected for this retrospective study. VMAT plans were generated for each patient using two different beam alignment techniques with the 6-MV flattening filter-free (FFF) photon beam: single-isocenter jaw-tracking VMAT based on the Varian TrueBeam linear accelerator (S-TV), and dual-isocenter VMAT based on both TrueBeam (D-TV) and Halcyon linear accelerator (D-HV). For all 45 treatment plans, planning target volume (PTV) dose coverage, conformity/homogeneity index (CI/HI), mean heart dose (MHD), mean lung dose (MLD) and the total lung tissue receiving 5, 20, 30 Gy (V5, V20, V30) were evaluated. The monitor units (MUs), delivery time, and plan quality assurance (QA) results were recorded. RESULTS: The quality of the objectives of the three plans was comparable to each other. In comparison with S-TV, D-TV and D-HV improved the CI and HI of the PTV (p < 0.05). The MLD was 13.84 ± 1.44 Gy (mean ± SD) for D-TV, 14.22 ± 1.30 Gy and 14.16 ± 1.42 Gy for S-TV and D-HV, respectively. Lungs-V5Gy was 50.78 ± 6.24%, 52.00 ± 7.32% and 53.36 ± 8.48%, Lungs-V20Gy was 23.72 ± 2.27%, 26.18 ± 2.86% and 24.96 ± 3.09%, Lungs-V30Gy was 15.69 ± 1.76%, 17.20 ± 1.72% and 16.52 ± 2.07%. Compared to S-TV, D-TV provided statistically significant better protection for the total lung, with the exception of the lungs-V5. All plans passed QA according the gamma criteria of 3%/3 mm. CONCLUSIONS: Taking into account the dosimetric results and published clinical data on radiation-induced pulmonary injury, dual-isocenter jaw-tracking VMAT may be the optimal choice for treating boot-shaped lung cancer.


Asunto(s)
Estudios de Factibilidad , Neoplasias Pulmonares , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Pulmonares/radioterapia , Órganos en Riesgo/efectos de la radiación , Estudios Retrospectivos , Aceleradores de Partículas/instrumentación
18.
J Appl Clin Med Phys ; 25(6): e14276, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38414322

RESUMEN

PURPOSE: Patient-specific quality assurance (PSQA) for vertebra stereotactic body radiation therapy (SBRT) presents challenges due to highly modulated small fields with high-dose gradients between the target and spinal cord. This study aims to explore the use of the SRS MapCHECK® (SRSMC) for vertebra SBRT PSQA. METHODS: Twenty vertebra SBRT treatment plans including prescriptions 20 Gy/1 fraction and 24 Gy/2 fractions were selected for each of Millennium (M)-Multileaf Collimator (MLC), and high-definition (HD)-MLC. All 40 plans were measured using Gafchromic EBT3 film (film) and SRSMC, using the StereoPHAN phantom. Plan complexity was assessed using modulation complexity score (MCS), edge metric (EM) (mm-1), modulation factor (MU/cGy), and average leaf pair opening (ALPO) (mm) and its correlation with gamma-pass rate was investigated. The high dose gradient between the target and the spinal cord was analyzed for film and SRSMC and compared against the treatment planning system (TPS). Applying the methodology proposed by AAPM TG-218, action and tolerance values specific to the SRSMC for vertebra SBRT were determined for ß values ranging from 5 to 8. RESULTS: Film and SRSMC gamma-pass rates showed no correlation (p > 0.05). A moderate negative correlation (R = -0.57, p = 0.01) is present between EM and SRSMC 3%/1 mm gamma-pass rate for HD-MLC plans. Both film and SRSMC accurately measured high dose gradients between the target and the spinal cord (R2 > 0.86, p ≤ 0.05). Notably, dose-gradient of HD-MLC plans is 22% steeper and has a smaller standard deviation to M-MLC plans (p ≤ 0.05). Applying TG-218, the film tolerance limit was 96% with action limit 95% for 5%/1 mm (ß = 6) and for the SRSMC tolerance limit was 97% with an action limit of 96% for 4%/1 mm (ß = 6). CONCLUSION: Our findings suggest that universal TG-218 limits may not be suitable for vertebra SBRT PSQA. This study demonstrates that SRSMC is a viable tool for vertebra SBRT PSQA, supported by TG-218 implementation of process-based tolerance and action limits.


Asunto(s)
Órganos en Riesgo , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Garantía de la Calidad de Atención de Salud/normas , Órganos en Riesgo/efectos de la radiación , Neoplasias de la Columna Vertebral/cirugía , Neoplasias de la Columna Vertebral/radioterapia
19.
J Appl Clin Med Phys ; 25(6): e14407, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38775807

RESUMEN

BACKGROUND: With the ever-increasing requirements of accuracy and personalization of radiotherapy treatments, stereotactic radiotherapy (SRT) with volumetric modulated arc therapy (VMAT) on O-ring Halcyon radiotherapy system could potentially provide a fast, safe, and feasible treatment option. PURPOSE: The purpose of this study was to assess the delivery of Halcyon VMAT plans for small targets. METHODS: Well-defined VMAT-SRT plans were created on Halcyon radiotherapy system with the stacked and staggered dual-layer MLC design for the film measurement set-up and the target sizes and shapes designed to emulate the targets of the stereotactic treatments. The planar dose distributions were acquired with film measurements and compared to a current clinical reference dose calculation with AcurosXB (v18.0, Varian Medical Systems) and to Monte Carlo simulations. With the collapsed arc versions of the VMAT-SRT plans, the uncertainty in dose delivery due to the multileaf collimator (MLC) without the gantry rotation could be separated and analyzed. RESULTS: The target size was mainly limited by the resolution originated from the design of the MLC leaves. The results of the collapsed arc versions of the plans show good consistency among measured, calculated, and simulated dose distributions. With the full VMAT plans, the agreement between calculated and simulated dose distributions was consistent with the collapsed arc versions. The measured dose distribution agreed with the calculated and simulated dose distributions within the target regions, but considerable local differences were observed in the margins of the target. The largest differences located in the steep gradient regions presumably originating from the deviation of the isocenter. CONCLUSIONS: The potential of the Halcyon radiotherapy system for VMAT-SRT delivery was evaluated and the study revealed valuable insights on the machine characteristics with the delivery.


Asunto(s)
Método de Montecarlo , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Radioterapia de Intensidad Modulada/métodos , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Aceleradores de Partículas/instrumentación , Neoplasias/radioterapia , Radiocirugia/métodos
20.
J Appl Clin Med Phys ; 25(5): e14295, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38335253

RESUMEN

PURPOSE/OBJECTIVE: Field size limitations on Halcyon and Ethos treatment machines largely preclude use of the conventional monoisocentric three-field technique for breast/chest wall and regional lymph nodes. We present an alternative, IMRT-based planning approach that facilitates treatment on Halcyon and Ethos while preserving plan quality. MATERIALS/METHODS: Eight breast and regional node cases (four left-sided, four right-sided) were planned for an Ethos machine using a 15-17 field IMRT technique. Institutional plan quality metrics for CTV and PTV coverage and OAR sparing were assessed. Five plans (four right-sided, one left-sided) were also planned using a hybrid 3D multisocenter technique. CTV coverage and OAR sparing were compared to the IMRT plans. Eclipse scripting tools were developed to aid in beam placement and plan evaluation through a set of dosimetric scorecards, and both are shared publicly. RESULTS: On average, the IMRT plans achieved breast CTV and PTV coverage at 50 Gy of 97.9% and 95.7%, respectively. Supraclavicular CTV and PTV coverages at 45 Gy were 100% and 95.5%. Axillary lymph node CTV and PTV coverages at 45 Gy were 100% and 97.1%, and IMN CTV coverage at 45 Gy was 99.2%. Mean ipsilateral lung V20 Gy was 19.3%, and average mean heart dose was 1.6 Gy for right-sided cases and 3.0 Gy for left-sided. In comparison to the hybrid 3D plans, IMRT plans achieved higher breast and supraclavicular CTV coverage (99.9% vs. 98.6% and 99.9% vs. 93.4%), higher IMN coverage (99.6% vs. 78.2%), and lower ipsilateral lung V20 Gy (19.6% vs. 28.2%). CONCLUSION: Institutional plan quality benchmarks were achieved for all eight cases using the IMRT-based planning approach. The IMRT-based planning approach offered superior conformity and OAR sparing than a competing hybrid 3D approach.


Asunto(s)
Neoplasias de la Mama , Ganglios Linfáticos , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Pared Torácica , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Femenino , Pared Torácica/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Neoplasias de la Mama/radioterapia , Ganglios Linfáticos/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA