Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Ophthalmol ; 23(1): 62, 2023 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-36782180

RESUMEN

BACKGROUND: To compare the 6-month changes in aberration and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for high astigmatism. METHODS: In this retrospective case control study, 47 eyes with high astigmatism (≥ 2.5 D, HA group) and 47 eyes with low astigmatism (≤ 1.0 D, LA group) underwent FS-LASIK. Preoperative and follow-up examinations included visual outcomes, higher order aberrations (HOAs) and biomechanics. Biomechanical parameters include a deformation amplitude ratio of 2 mm (DA ratio 2 mm), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), and ambrosio relational thickness through the horizontal meridian (ARTh). RESULTS: Six months postoperatively, there was no significant difference in the efficacy and safety index (both P > 0.05) between the two groups, but the cylinder was higher in the HA group. The HOAs increased significantly after surgery in both groups (all P < 0.05). Six months postoperatively, the changes in spherical aberration and HOAs were larger in the HA group (both P < 0.005), but there was no significant difference between the changes in coma (P > 0.05). Significant decreases in SP-A1 and ARTh and significant increases in the IIR and DA ratio of 2 mm (all P < 0.05) were observed after surgery in both groups. The changes in the DA ratio 2 mm, IIR, SP-A1, and ARTh were not significantly different between the groups. CONCLUSION: FS-LASIK had relative comparable efficacy and safety in correcting high and low myopic astigmatism, with higher astigmatic under-correction in eyes with high astigmatism. High astigmatism in eyes after FS-LASIK could introduce larger corneal aberrations, but the impact on corneal stiffness was the same as that in eyes with low astigmatism.


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Miopía , Humanos , Astigmatismo/cirugía , Estudios Retrospectivos , Estudios de Casos y Controles , Agudeza Visual , Fenómenos Biomecánicos , Aberración de Frente de Onda Corneal/cirugía , Miopía/cirugía , Láseres de Excímeros , Refracción Ocular
2.
BMC Ophthalmol ; 22(1): 347, 2022 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-35978275

RESUMEN

BACKGROUND: Few studies have reported the visual outcomes of small-incision lenticule extraction (SMILE) and laser-assisted subepithelial keratomileusis (LASEK) for myopia correction. This study aims to compare the visual quality and corneal wavefront aberrations after SMILE and LASEK for low-myopia correction. METHODS: In this prospective study, we included 29 eyes of 29 patients who received SMILE and 23 eyes of 23 patients who received LASEK between June 2018 and January 2019. The following measurements were assessed: uncorrected (UDVA) and corrected (CDVA) distance visual acuity, manifest refraction, corneal wavefront aberrations, and subjective visual quality. All patients were followed up for two years. RESULTS: All procedures were uneventful. An efficacy index of 1.19 ± 0.17 was established in the SMILE group and 1.23 ± 0.20 in the LASEK group. No eyes lost more than two lines of CDVA. We found that 93% (27/29) of the treated eyes in the SMILE group and 91% (21/23) in the LASEK group had spherical equivalent (SE) within ± 0.25D. The increases in the total corneal spherical aberration and the corneal front spherical aberration were lower in the SMILE group than in the LASEK group (P < 0.01). In contrast, the increases in the total corneal vertical coma and the corneal front vertical coma in the SMILE group were greater than those in the LASEK group (P < 0.01). CONCLUSION: Both SMILE and LASEK have good safety, stability, and patient-reported satisfaction for low myopia. SMILE induced less corneal spherical aberration but greater vertical coma than LASEK.


Asunto(s)
Aberración de Frente de Onda Corneal , Queratectomía Subepitelial Asistida por Láser , Queratomileusis por Láser In Situ , Miopía , Coma/cirugía , Sustancia Propia/cirugía , Aberración de Frente de Onda Corneal/cirugía , Humanos , Queratectomía Subepitelial Asistida por Láser/métodos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Estudios Prospectivos , Refracción Ocular
3.
Cochrane Database Syst Rev ; 12: CD012687, 2020 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-33336797

RESUMEN

BACKGROUND: Refractive errors (conditions in which the eye fails to focus objects accurately on the retina due to defects in the refractive system), are the most common cause of visual impairment. Myopia, hyperopia, and astigmatism are low-order aberrations, usually corrected with spectacles, contact lenses, or conventional refractive surgery. Higher-order aberrations (HOAs) can be quantified with wavefront aberration instruments and corrected using wavefront-guided or wavefront-optimized laser surgery. Wavefront-guided ablations are based on preoperative measurements of HOAs; wavefront-optimized ablations are designed to minimize induction of new HOAs while preserving naturally occurring aberrations. Two wavefront procedures are expected to produce better visual acuity than conventional procedures. OBJECTIVES: The primary objective was to compare effectiveness and safety of wavefront procedures, laser-assisted in-situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) or laser epithelial keratomileusis (LASEK) versus corresponding conventional procedures, for correcting refractive errors in adults for postoperative uncorrected visual acuity, residual refractive errors, and residual HOAs. The secondary objective was to compare two wavefront procedures. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, which contains the Cochrane Eyes and Vision Trials Register; 2019, Issue 8); Ovid MEDLINE; Ovid Embase; Latin American and Caribbean Health Sciences (LILACS); the ISRCTN registry; ClinicalTrials.gov and the WHO ICTRP. The date of the search was 6 August 2019. We imposed no restrictions by language or year of publication. We used the Science Citation Index (September 2013) and searched the reference lists of included trials to identify additional relevant trials. SELECTION CRITERIA: We included randomized controlled trials (RCTs) comparing either wavefront modified with conventional refractive surgery or wavefront-optimized with wavefront-guided refractive surgery in participants aged ⪰ 18 years with refractive errors. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methodology. MAIN RESULTS: We identified 33 RCTs conducted in Asia, Europe and United States, totaling 1499 participants (2797 eyes). Participants had refractive errors ranging from high myopia to low hyperopia. Studies reported at least one of the following review-specific outcomes based on proportions of eyes: with uncorrected visual acuity (UCVA) of 20/20 or better, without loss of one or more lines of best spectacle-corrected visual acuity (BSCVA), within ± 0.50 diopters (D) of target refraction, with HOAs and adverse events. Study characteristics and risk of bias Participants were mostly women, mean age 29 and 53 years, and without previous refractive surgery, ocular pathology or systemic comorbidity. We could not judge risks of bias for most domains of most studies. Most studies in which both eyes of a participant were analyzed failed to account for correlations between two eyes in the analysis and reporting of outcomes. Findings For the primary comparison between wavefront (PRK or LASIK or LASEK) and corresponding conventional procedures, 12-month outcome data were available from only one study of PRK with 70 participants. No evidence of more favorable outcomes of wavefront PRK on proportion of eyes: with UCVA of 20/20 or better (risk ratio [RR] 1.03, 95% confidence interval (CI) 0.86 to 1.24); without loss of one or more lines of BSCVA (RR 0.94, 95% CI 0.81 to 1.09); within ± 0.5 D of target refraction (RR 1.03, 95% CI 0.86 to 1.24); and mean spherical equivalent (mean difference [MD] 0.04, 95% CI -0.11 to 0.18). The evidence for each effect estimate was of low certainty. No study reported HOAs at 12 months. At six months, the findings of two to eight studies showed that overall effect estimates and estimates by subgroup of PRK or LASIK or LASEK were consistent with those for PRK at 12 month, and suggest no difference in all outcomes. The certainty of evidence for each outcome was low. For the comparison between wavefront-optimized and wavefront-guided procedures at 12 months, the overall effect estimates for proportion of eyes: with UCVA of 20/20 or better (RR 1.00, 95% CI 0.99 to 1.02; 5 studies, 618 participants); without loss of one or more lines of BSCVA (RR 0.99, 95% CI 0.96 to 1.02; I2 = 0%; 5 studies, 622 participants); within ± 0.5 diopters of target refraction (RR 1.02, 95% CI 0.95 to 1.09; I2 = 33%; 4 studies, 480 participants) and mean HOAs (MD 0.03, 95% CI -0.01 to 0.07; I2 = 41%; 5 studies, 622 participants) showed no evidence of a difference between the two groups. Owing to substantial heterogeneity, we did not calculate an overall effect estimate for mean spherical equivalent at 12 months, but point estimates consistently suggested no difference between wavefront-optimized PRK versus wavefront-guided PRK. However, wavefront-optimized LASIK compared with wavefront-guided LASIK may improve mean spherical equivalent (MD -0.14 D, 95% CI -0.19 to -0.09; 4 studies, 472 participants). All effect estimates were of low certainty of evidence. At six months, the results were consistent with those at 12 months based on two to six studies. The findings suggest no difference between two wavefront procedures for any of the outcomes assessed, except for the subgroup of wavefront-optimized LASIK which showed probable improvement in mean spherical equivalent (MD -0.12 D, 95% CI -0.19 to -0.05; I2 = 0%; 3 studies, 280 participants; low certainty of evidence) relative to wavefront-guided LASIK. We found a single study comparing wavefront-guided LASIK versus wavefront-guided PRK at six and 12 months. At both time points, effect estimates consistently supported no difference between two procedures. The certain of evidence was very low for all estimates. Adverse events Significant visual loss or optical side effects that were reported were similar between groups. AUTHORS' CONCLUSIONS: This review suggests that at 12 months and six months postoperatively, there was no important difference between wavefront versus conventional refractive surgery or between wavefront-optimized versus wavefront-guided surgery in the clinical outcomes analyzed. The low certainty of the cumulative evidence reported to date suggests that further randomized comparisons of these surgical approaches would provide more precise estimates of effects but are unlikely to modify our conclusions. Future trials may elect to focus on participant-reported outcomes such as satisfaction with vision before and after surgery and effects of remaining visual aberrations, in addition to contrast sensitivity and clinical outcomes analyzed in this review.


Asunto(s)
Aberración de Frente de Onda Corneal/cirugía , Queratectomía Subepitelial Asistida por Láser/métodos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Queratectomía Fotorrefractiva/métodos , Adulto , Astigmatismo/cirugía , Femenino , Humanos , Hiperopía/cirugía , Queratectomía Subepitelial Asistida por Láser/efectos adversos , Queratomileusis por Láser In Situ/efectos adversos , Masculino , Persona de Mediana Edad , Miopía/cirugía , Queratectomía Fotorrefractiva/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento , Agudeza Visual
4.
Graefes Arch Clin Exp Ophthalmol ; 257(1): 233-240, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30368563

RESUMEN

PURPOSE: To determine the association between anterior corneal curvature and optical zone centration as well as its impact on aberration profiles in small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK). METHODS: Seventy-eight eyes of 78 patients treated with SMILE (45 eyes) and LASIK (33 eyes) were included. The centration of the optical zone was evaluated on the instantaneous curvature difference map between the preoperative and 3-month postoperative scans using a superimposed set of concentric circles. The correlation between optical zone decentration and anterior keratometry values was evaluated. The effect of optical zone decentration on vector components of astigmatic correction and induction of higher-order aberrations (HOA) was assessed. RESULTS: The mean decentration distance was 0.21 ± 0.11 mm for SMILE and 0.20 ± 0.09 mm for LASIK (p = 0.808). There was a significant correlation between anterior keratometric astigmatism and decentration distance (r = 0.653, p < 0.001) for SMILE but not for LASIK (r = - 0.264, p = 0.138). Astigmatic correction was performed in 67 eyes. Optical zone decentration and the vector components of astigmatic correction were not correlated (p ≥ 0.420). Significant correlation was demonstrated between the decentration distance and the induced total coma (SMILE: r = 0.384, p = 0.009; LASIK: r = 0.553, p = 0.001) as well as the induced total HOA (SMILE: r = 0.498, p = 0.001; LASIK: r = 0.555, p = 0.001). CONCLUSION: Anterior cornea astigmatism affected the treatment centration in SMILE but not LASIK. Subclinical decentration was associated with the induction of total coma and total HOA, but it did not affect the lower-order astigmatic correction.


Asunto(s)
Astigmatismo/cirugía , Córnea/patología , Aberración de Frente de Onda Corneal/cirugía , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Refracción Ocular/fisiología , Agudeza Visual , Adulto , Astigmatismo/patología , Astigmatismo/fisiopatología , Córnea/cirugía , Topografía de la Córnea , Aberración de Frente de Onda Corneal/diagnóstico , Aberración de Frente de Onda Corneal/fisiopatología , Femenino , Humanos , Masculino , Periodo Posoperatorio , Estudios Prospectivos
5.
BMC Ophthalmol ; 19(1): 138, 2019 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-31248387

RESUMEN

BACKGROUND: This study compares the clinical outcomes of femtosecond laser small-incision lenticule extraction (SMILE) for the correction of myopia and myopic astigmatism greater than - 10 D, and - 10 D or less respectively. METHODS: 60 eyes/patients were equally selected into group 1 (myopia and myopic astigmatism of - 10 D or less) and group 2 (myopia and myopic astigmatism of over - 10 D), both of which were treated with SMILE. Visual and refractive outcomes, corneal higher-order aberrations, and Bowman's layer micro-distortions were evaluated preoperatively, 3 months, and 6 months postoperatively. RESULTS: LogMAR corrected distance visual acuity (CDVA) of group 1 and group 2 was - 0.069 ± 0.047 and - 0.053 ± 0.073 6 months postoperatively (P = 0.48). 100% eyes in group 1 and 97% in group 2 were within 1 D of targeted correction (P = 0.45). Meanwhile, 100% eyes in group 1 and 97% in group 2 had an uncorrected distance visual acuity of 20/25 or better (P = 0.20). Changes in corneal higher-order aberrations root mean square, coma, and trefoil were similar between the two groups but spherical aberration was higher in group 2 (P < 0.01). Micro-distortions were observed in 53% in group 1 and 77% in group 2. More micro-distortions were observed in group 2 (3.40 ± 2.66) than in group 1 (2.07 ± 2.29) (P = 0.041). The total number of micro-distortions was not correlated with postoperative CDVA (P = 0.77). CONCLUSIONS: Visual outcomes showed similar results of SMILE for myopic correction of > - 10 D and ≤ - 10 D. Refractive outcomes showed slightly under-correction in higher myopic eyes. Higher myopic treatment tends to induce more spherical aberrations. Micro-distortions had no impact in visual and refractive outcomes.


Asunto(s)
Lámina Limitante Anterior/cirugía , Aberración de Frente de Onda Corneal/cirugía , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Refracción Ocular/fisiología , Agudeza Visual , Aberrometría , Adolescente , Adulto , Córnea/diagnóstico por imagen , Córnea/cirugía , Topografía de la Córnea , Aberración de Frente de Onda Corneal/diagnóstico , Femenino , Humanos , Masculino , Microcirugia , Persona de Mediana Edad , Miopía/fisiopatología , Estudios Prospectivos , Adulto Joven
6.
BMC Ophthalmol ; 18(1): 154, 2018 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-29940974

RESUMEN

BACKGROUND: To compare the clinical outcomes of wavefront-optimized (WFO) transepithelial photorefractive keratectomy (trans-PRK) and corneal wavefront-guided (CWFG) trans-PRK for myopic eyes with moderate to high astigmatism. METHODS: One hundred ninety-six eyes (196 patients) with moderate to high astigmatism (≥ 1.75 D) treated with WFO or CWFG trans-PRK (101 and 95 eyes, respectively) were retrospectively registered. Safety, efficacy, predictability, vector analysis, and corneal aberrations were compared between groups preoperatively and at 6 months postoperatively. RESULTS: At postoperative 6 months, the mean logMAR uncorrected distance visual acuity was similar in the WFO (- 0.07 ± 0.08) and CWFG (- 0.07 ± 0.07) groups. Safety, efficacy, and predictability of refractive and visual outcomes were also similar. The correction indices were 1.02 ± 0.14 and 1.03 ± 0.13 in the WFO and CWFG groups, respectively, with no significant difference. The absolute values of the angle of error were significantly higher in the WFO group (2.28 ± 2.44 vs. 1.40 ± 1.40; P = 0.002). Corneal total root mean square higher-order aberrations and corneal spherical aberrations increased postoperatively in both groups; however, the change was smaller in the CWFG group. Corneal coma showed a significant increase postoperatively only in the WFO group. CONCLUSIONS: WFO and CWFG trans-PRK are safe and effective for correcting moderate to high astigmatism. However, CWFG trans-PRK provides a more predictable astigmatism correction axis and fewer induced corneal aberrations.


Asunto(s)
Astigmatismo/cirugía , Aberración de Frente de Onda Corneal/etiología , Epitelio Corneal/cirugía , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Queratectomía Fotorrefractiva/métodos , Refracción Ocular , Adolescente , Adulto , Astigmatismo/complicaciones , Astigmatismo/fisiopatología , Topografía de la Córnea , Aberración de Frente de Onda Corneal/diagnóstico , Aberración de Frente de Onda Corneal/cirugía , Epitelio Corneal/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Miopía/complicaciones , Miopía/fisiopatología , Periodo Posoperatorio , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual , Adulto Joven
7.
J Med Assoc Thai ; 99 Suppl 4: S178-81, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29926699

RESUMEN

Background: Pterygium may induce pressure and distortion on the corneal surface leading to ocular aberrations. Objective: To evaluate higher order aberrations in pterygium eyes. Material and Method: Thirty-two patients with unilateral primary pterygium were enrolled. Wavefront analysis technique was used to determine the higher order aberrations in pterygium eyes and normal fellow eyes in individuals. Higher order aberration values were compared between both eyes with paired t-test. Pearson correlation was used to assess the correlations of higher order aberration values with pterygium size. Results: Of the 32 patients, there were 15 males (47%) and 17 females (53%), mean age was 48.9±12.2 years. The average horizontal size of pterygium was 2.6+0.9 millimeters. For pterygium eyes, the mean of coma, trefoil, spherical aberration, and quadrafoil were 0.87±1.01, 1.45±1.55, 0.28±0.27, and 0.79±0.94 micrometers, respectively. And those of normal fellow eyes were 0.46±0.37, 0.80±0.71, 0.15±0.33, and 0.39±0.47 micrometers, respectively. Comparing between pterygium and contralateral normal eyes, a significant difference was present in all parameters (paired t-test, p<0.05). Coma, trefoil, and quadrafoil of pterygium eyes had a significant relationship with pterygium size (Pearson correlation, p<0.05) except for spherical aberration. Conclusion: The findings suggest that higher order aberrations have a tendency to increase in pterygium eyes compared to contralateral normal eyes, and most have a correlation with pterygium size.


Asunto(s)
Topografía de la Córnea , Aberración de Frente de Onda Corneal/cirugía , Pterigion/cirugía , Adulto , Córnea , Aberración de Frente de Onda Corneal/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Oftalmológicos , Pterigion/fisiopatología
8.
Zhonghua Yan Ke Za Zhi ; 50(1): 27-31, 2014 Jan.
Artículo en Zh | MEDLINE | ID: mdl-24709130

RESUMEN

OBJECTIVE: To compare the higher order aberration of wavefront-guided aspherical versus wavefront-guided and Q-value guided aspheric personalized LASIK surgery in the treatment of myopia. METHODS: Prospective study.120 patients with myopia and/or astigmatism(240 eyes) were involved in our hospital from August 2010 to December 2010. There was a prospective study, divided into three groups: Wavefront-guided aspherical personalized LASIK in group A; Wavefront-guided LASIK in group B; Q-value guided aspheric LASIK in group C. The follow-up time was 6 months. The comparison of data before and after operation was two independent samples t test. The comparison among three groups was one-way analysis of variance, and multiple comparison between groups was Dunnet t test. RESULTS: A group: The differences between before and after surgery were not statistically significant in higher order aberration (t1 week = 0.874, P1 week = 0.387; t1 month = -1.145, P1 month = 0.259; t3 month = 0.652, P3 month = 0.518; t 6 month = 0.496, P6 month = 0.439) , but as the extension of time, The values have a tendency to become smaller; the difference was not statistically significant in spherical aberration between before and after surgery 1 week (t = -1.815, P = 0.077), and was statistically significant between before and after surgery 1 month, 3 months and 6 months after surgery (t1 month = -4.410, P1 month = 0.000; t3 month = -2.375, P 3 month = 0.022; t6 month = -1.870, P 6 month = 0.000) , the values after surgery were higher. The differences between before and after surgery were not statistically significant in coma aberration (t1 week = 1.028, P 1 week = 0.310; t1 month = 0.847, P1 month = 0.402; t3 month = 0.210, P3 month = 0.984; t6 month = 0.533, P6 month = 0.597). At 6 months, the higher order aberration and spherical aberration in A group and C group were significantly lower than the B group, and the differences were statistically significant (P A&B = 0.000; PC&B = 0.000) , the differences between A group and C group were not statistically significant in higher order aberration and spherical aberration(P = 0.866), but A group is less than the C group in changes before and after surgery. The differences among three groups were not statistically significant in the vertical and horizontal coma (Fvertical coma = 0.367, Pvertical coma = 0.683; Fhorizontal coma = 0.254, Phorizontal coma = 0.797). CONCLUSION: Wavefront-guided aspherical personalized LASIK compared with wavefront-guided personalized LASIK can better reduce the increases of the higher order aberration and spherical aberration, and the changes between preoperative and postoperative is less than Q-value guided aspheric personalized LASIK.


Asunto(s)
Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros , Miopía/fisiopatología , Adolescente , Adulto , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/cirugía , Femenino , Humanos , Masculino , Miopía/cirugía , Estudios Prospectivos , Refracción Ocular , Agudeza Visual , Adulto Joven
9.
J Cataract Refract Surg ; 50(4): 430-435, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38523280

RESUMEN

A 28-year-old nurse had an aberration-free femto-laser in situ keratomileusis (LASIK) performed for her myopia of -6.25 -0.50 × 096 and -6.75 -0.50 × 175 in the right and left eye, respectively. Corrected distance visual acuity (CDVA) preoperatively was 20/16. Preoperatively, there were no abnormalities on Scheimpflug imaging, and a pachymetry of 585 µm was measured in both eyes. Flap thickness was 115 µm. The patient was quite nervous during the surgery. Since the surgery, her uncorrected distance visual acuity (UDVA) and CDVA are suboptimal at 20/30 and 20/20 in the right eye, and 20/20 and 20/16 in the left eye. 3 months postoperatively, there is a stable manifest refraction of +0.25 -1.25 × 030 and +0.25 -0.00 × 0. The keratometric astigmatism in the Scheimpflug imaging is 1.2 diopter (D) × 114 and 0.4 D × 78 in the right and left eyes, respectively (FIgures 1 and 2). Thinnest pachymetry is 505 µm and 464 µm in the right and left eye, respectively. Her wavefront analysis shows refraction in a 6 mm zone of -0.99 -1.22 × 32 and -0.91 -0.36 × 136. The cycloplegic refraction is 1.25 -1.00 × 023 and +1.00 -0.25 × 006 (Figures 3 and 4). What is the cause of the suboptimal visual outcome in this case? What would be your treatment strategy to improve visual outcome?


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Miopía , Humanos , Femenino , Adulto , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/cirugía , Resultado del Tratamiento , Agudeza Visual , Refracción Ocular , Miopía/cirugía , Miopía/complicaciones , Astigmatismo/cirugía , Astigmatismo/complicaciones , Láseres de Excímeros/uso terapéutico
10.
Graefes Arch Clin Exp Ophthalmol ; 251(1): 341-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22588290

RESUMEN

BACKGROUND: To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL METHODS: Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). RESULTS: A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. CONCLUSIONS: The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.


Asunto(s)
Astigmatismo/diagnóstico , Aberración de Frente de Onda Corneal/diagnóstico , Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Aberrometría , Adulto , Astigmatismo/cirugía , Topografía de la Córnea , Aberración de Frente de Onda Corneal/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Adulto Joven
11.
Graefes Arch Clin Exp Ophthalmol ; 251(2): 609-16, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22926254

RESUMEN

PURPOSE: To compare clinical outcomes of wavefront-guided LASIK with and without aspheric compensation in myopic eyes. METHODS: In this observational, single-center study, 134 eyes were treated using an aspheric module in combination with wavefront-guided profiles (PTA-algorithm) and compared to 146 eyes treated with the predecessor wavefront-guided software (APT) that has no aspheric compensation. All treatment plans included the Rochester nomogram that accounts for the preoperative manifest refraction and interaction of higher order aberrations. Active eye-tracking (including cyclorotational movements) was utilized during photoablation. RESULTS: Results at the 3-month follow-up: 67 % of PTA-treated eyes and 39 % of APT-treated eyes achieved an uncorrected distance visual acuity (UDVA) of 20/20 or better. Change in mean higher order aberration root-mean-square (HOA RMS) after PTA treatments was not statistically significant (p = 0.18). The increase in HOA RMS after APT treatments was statistically significant (p = 0.003). Change in mean postop spherical aberration (SA) after PTA treatments was not statistically significant (p = 0.27). The change in SA after APT treatments was statistically significant (p = 0.001). In both cohorts, mean uncorrected low-contrast visual acuity was statistically not different to preoperative corrected values. CONCLUSIONS: Adding an aspheric compensation to wavefront-guided myopic LASIK statistically improved clinical results in terms of visual acuity and refractive outcomes. Low-contrast visual acuity was not negatively affected in either group. While in APT-treated eyes mean HOA RMS and mean SA were significantly increased postoperatively, PTA-treated eyes showed neither induced HOA RMS nor induced SA.


Asunto(s)
Astigmatismo/cirugía , Aberración de Frente de Onda Corneal/cirugía , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Aberrometría , Adulto , Anciano , Algoritmos , Astigmatismo/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Nomogramas , Refracción Ocular/fisiología , Resultado del Tratamiento , Agudeza Visual/fisiología , Adulto Joven
12.
J Refract Surg ; 39(1): 23-32, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36630428

RESUMEN

PURPOSE: To investigate the corneal epithelial remodeling profile after small incision lenticule extraction (SMILE), the correlated explanatory variables, and its potential impact on corneal higher order aberrations (HOAs). METHODS: This single-center study prospectively evaluated 75 right eyes of 75 patients scheduled for SMILE. An anterior segment optical coherence tomography device was used to automatically obtain central 6-mm corneal epithelial thickness (ET), total corneal HOAs, and individual Zernike components before and after surgery. The ET inhomogeneity over the central 3- and 6-mm cornea was quantified with coefficient of variance (CV). RESULTS: Both ET and CV significantly increased 1 month postoperatively (all P < .05). The stepwise multiple regression analysis showed that ET and CV were significantly correlated with preoperative ET and CV, respectively (all P < .01). The corrected spherical equivalent also significantly influenced ET and CV (all P < .01). Over the central 6-mm zone, the alterations of total corneal HOAs and individual Zernike components such as vertical coma (Z7) and spherical aberration (Z12, Z24) were significantly correlated with ET and CV (all P < .05). CONCLUSIONS: The SMILE-induced epithelial remodeling involved both ET and ET inhomogeneity. The modulation was associated with preoperative and treatment parameters, and exerted a significant impact on corneal HOA alterations especially over the central 6-mm cornea. Together with the amount of correction and corneal curvature gradient change, preoperative assessment of ET and ET inhomogeneity might help predict postoperative epithelial remodeling. [J Refract Surg. 2023;39(1):23-32.].


Asunto(s)
Cirugía Laser de Córnea , Aberración de Frente de Onda Corneal , Miopía , Herida Quirúrgica , Humanos , Sustancia Propia/cirugía , Agudeza Visual , Cirugía Laser de Córnea/métodos , Miopía/cirugía , Aberración de Frente de Onda Corneal/etiología , Aberración de Frente de Onda Corneal/cirugía , Córnea , Láseres de Excímeros/uso terapéutico , Topografía de la Córnea
13.
Biomed Res Int ; 2023: 3430742, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36778055

RESUMEN

Purpose: To investigate changes in corneal densitometry (CD) and visual quality following small incision lenticule extraction (SMILE) and laser epithelial keratomileusis (LASEK) in patients with mild-to-moderate myopia. Methods: A retrospective analysis was performed on 24 and 25 patients (46 eyes each) who underwent SMILE and LASEK, respectively, for mild-to-moderate myopia. The visual quality and CD values were recorded. Using the Pentacam Scheimpflug system, CD values were collected in three concentric optical zones at the depths of the anterior, central, and posterior layers. Efficacy, safety, predictability, corneal wavefront aberrations, and QoV scores were measured to evaluate visual quality. A correlation analysis was performed between changes in CD and clinical characteristics. Results: There were no statistical differences in efficacy and safety indices between the two groups. At 3 months postoperatively, a pronounced reduction in several zones was observed in the LASEK group (p < 0.05), whereas no obvious change was observed in the SMILE group. There were obvious changes in the CD values in several zones in the SMILE and LASEK groups (p < 0.05) after 1 year. The magnitude of the CD changes in the anterior and central corneal layers was smaller in the SMILE group than in the LASEK group (all p < 0.05). Lower HOAs, spherical aberration, and horizontal comas of the anterior and whole corneal surfaces were observed in the SMILE group. QoV scores were similar between the two groups. Conclusion: CD decreased in the SMILE and LASEK groups after 1 year; there was a smaller reduction in SMILE than in LASEK. SMILE and LASEK did not differ significantly in terms of safety and effectiveness in correcting mild-to-moderate myopia.


Asunto(s)
Aberración de Frente de Onda Corneal , Queratectomía Subepitelial Asistida por Láser , Queratomileusis por Láser In Situ , Miopía , Herida Quirúrgica , Humanos , Sustancia Propia/cirugía , Estudios Retrospectivos , Agudeza Visual , Láseres de Excímeros/uso terapéutico , Estudios Prospectivos , Miopía/cirugía , Aberración de Frente de Onda Corneal/cirugía , Densitometría , Refracción Ocular
14.
J Refract Surg ; 39(11): 741-750, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37937754

RESUMEN

PURPOSE: To explore size, decentration, and eccentricity of effective optical zones (EOZs) in laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and small incision lenticule extraction (SMILE) and correlate them to higher order aberrations (HOAs). METHODS: This was a retrospective chart review of 188 eyes that underwent refractive surgery for compound myopia (61 LASIK, 84 PRK, 43 SMILE). EOZ measurements were determined using 1-year postoperative Pentacam (Oculus Optikgeräte GmbH) tangential difference maps. HOA data were measured using Pentacam wavefront aberration Zernike polynomials. Correlations between EOZs and HOAs were analyzed. RESULTS: The EOZs of LASIK and PRK are smaller than SMILE at 19.54 ± 1.44, 19.39 ± 1.66, and 22.18 ± 2.61 mm2, respectively (P < .001). No difference existed in absolute decentration from corneal vertex (P = .078) or pupil center (P = .131), but horizontal and vertical components differed significantly (P < .001). Smaller EOZ areas were correlated with greater spherical aberration induction (rLASIK = -0.378, rPRK = -0.555, rSMILE = -0.501) and total HOA induction in all groups. Absolute decentration from corneal vertex positively correlated with total HOA (rLASIK = 0.396, rPRK = 0.463, rSMILE = 0.399) and directional vertical coma induction negatively correlated with vertical decentration from the corneal vertex (rLASIK = -0.776, rPRK = -0.665, rSMILE = -0.576) in all groups. CONCLUSIONS: SMILE results in a larger EOZ than LASIK and PRK, and absolute decentration remains comparable regardless of surgical reference center, despite horizontal/vertical differences. Surgical planning to ensure adequate EOZ size and centration may reduce induction of HOAs, including spherical aberrations and vertical coma. [J Refract Surg. 2023;39(11):741-750.].


Asunto(s)
Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Miopía , Queratectomía Fotorrefractiva , Humanos , Queratomileusis por Láser In Situ/métodos , Agudeza Visual , Estudios Retrospectivos , Coma/cirugía , Topografía de la Córnea , Aberración de Frente de Onda Corneal/cirugía , Láseres de Excímeros/uso terapéutico , Miopía/cirugía
15.
Eye (Lond) ; 37(18): 3768-3775, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37277614

RESUMEN

BACKGROUND: To evaluate vision 3 months after SmartSight lenticule extraction treatments. DESIGN: Case series. METHODS: This case series of patients were treated at Specialty Eye Hospital Svjetlost in Zagreb, Croatia. Sixty eyes of 31 patients consecutively treated with SmartSight lenticule extraction were assessed. The mean age of the patients was 33 ± 6 years (range 23-45 years) at the time of treatment with a mean spherical equivalent refraction of -5.10 ± 1.35 D and mean astigmatism of 0.46 ± 0.36 D. Monocular corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA) were assessed pre- and post-operatively. Ocular and corneal wavefront aberrations have been postoperatively compared to the preoperative baseline values. Changes in ocular wavefront refraction, as well as changes in keratometric readings are reported. RESULTS: At 3 months post-operatively, mean UDVA was 20/20 ± 2. Spherical equivalent showed a low myopic residual refraction of -0.37 ± 0.58 D with refractive astigmatism of 0.46 ± 0.26 D postoperatively. There was a slight improvement of 0.1 Snellen lines at 3-months follow-up. Compared to the preoperative status, ocular aberrations (at 6 mm diameter) did not change at 3 months follow-up; whereas corneal aberrations increased (+0.22 ± 0.21 µm for coma; +0.17 ± 0.19 µm for spherical aberration; and +0.32 ± 0.26 µm for HOA-RMS). The same correction was determined using changes in ocular wavefront refraction, as well as changes in keratometric readings. CONCLUSION: Lenticule extraction after SmartSight is safe and efficacious in the first 3 months postoperatively. The post-operative outcomes indicate improvements in vision.


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Astigmatismo/cirugía , Topografía de la Córnea , Resultado del Tratamiento , Láseres de Excímeros/uso terapéutico , Refracción Ocular , Aberración de Frente de Onda Corneal/cirugía , Sustancia Propia
16.
J Refract Surg ; 39(11): 751-758, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37937761

RESUMEN

PURPOSE: To evaluate refractive results, corneal higher order aberrations (HOAs), and epithelial remodeling in the preoperative and postoperative period of regular corneas that had topography-guided femtosecond laser-assisted laser in situ keratomileusis (LASIK) (Contoura WaveLight; Alcon Laboratories, Inc) and compare them with the contralateral eye that underwent ablation customized by asphericity (Custom-Q WaveLight; Alcon Laboratories, Inc) in myopic eyes with or without astigmatism. METHODS: A prospective, randomized, and double-blind study was conducted. Patients underwent preoperative and postoperative epithelial mapping and corneal tomography to assess the epithelial thickness map, HOAs of the corneal anterior surface, visual acuity, and refractive evaluation. RESULTS: This study enrolled 96 normal eyes of 48 patients. Uncorrected distance visual acuity of 20/20 or better was achieved in 97% of patients and gains in corrected distance visual acuity and effectiveness in correcting refractive astigmatism were similar in both techniques. Seventeen sectors of the corneal epithelium map were assessed by spectral-domain optical coherence tomography and no significant differences were found between techniques preoperatively and postoperatively (P > .05). HOA root mean square, coma Z3±1, trefoil Z3-3, and tissue consumption exhibited statistically significant between-technique differences (P < .05). CONCLUSIONS: The Contoura and Custom-Q techniques were similar with respect to refractive and visual outcomes after 3 months, as well as in epithelial remodeling. The Contoura provides lower postoperative HOA root mean square, coma Z3±1, and trefoil Z3-3 values, but the techniques showed no differences in the correction of the corneal astigmatic wavefront component and in the spherical aberration after 3 months. [J Refract Surg. 2023;39(11):751-758.].


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Humanos , Queratomileusis por Láser In Situ/métodos , Estudios Prospectivos , Astigmatismo/cirugía , Método Doble Ciego , Coma/cirugía , Topografía de la Córnea/métodos , Aberración de Frente de Onda Corneal/cirugía , Resultado del Tratamiento , Córnea/cirugía , Láseres de Excímeros/uso terapéutico
17.
J Refract Surg ; 28(1): 48-52, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22074466

RESUMEN

PURPOSE: To assess the performance and optical limitations of intraocular lenses (IOLs) correcting both longitudinal spherical aberration (LSA) and longitudinal chromatic aberration (LCA) compared to standard spherical and aspheric IOLs. METHODS: Using a set of 46 white light, pseudophakic eye models representing a population of cataract patients, retinal image quality was assessed for three IOL designs-standard spherical IOLs; aspheric IOLs, correcting a fixed amount of LSA; and aspheric refractive/diffractive IOLs, correcting a fixed amount of LSA and LCA. Depth of field and tolerance to IOL misalignments were also assessed. RESULTS: The improvement factor, based on the area under the radial polychromatic modulation transfer function (pMTF) curve of the IOL, correcting both average LSA and LCA over the aspheric IOL was 1.19±0.12, and over the spherical IOL was 1.43±0.29. Within the range of ±1.00 diopter of defocus, pMTF of the IOL correcting both LSA and LCA was equal or higher than both the spherical and aspheric IOLs. The IOL could be decentered up to 0.6 to 0.8 mm before the performance degraded below that of a spherical IOL. CONCLUSIONS: This is the first study that evaluates IOLs correcting both LSA and LCA in the presence of corneal higher order aberrations. Intraocular lenses that correct both LSA and LCA improve simulated retinal image quality over spherical IOLs and IOLs that correct LSA alone, without sacrificing depth of field or tolerance to decentration. Correction of LCA in combination with LSA shows the potential to improve visual performance.


Asunto(s)
Aberración de Frente de Onda Corneal/cirugía , Lentes Intraoculares , Modelos Teóricos , Óptica y Fotónica , Refracción Ocular/fisiología , Percepción de Profundidad/fisiología , Humanos , Implantación de Lentes Intraoculares , Seudofaquia/fisiopatología
18.
J Refract Surg ; 28(5): 347-52, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22515177

RESUMEN

PURPOSE: To evaluate the long-term outcomes of aspheric corneal wavefront ablation profiles for excimer laser retreatment. METHODS: Eighteen eyes that had previously undergone LASIK or photorefractive keratectomy (PRK) were retreated with LASIK using the corneal wavefront ablation profile. Custom Ablation Manager (SCHWIND eye-tech-solutions, Kleinostheim, Germany) software and the ESIRIS flying spot excimer laser system (SCHWIND) were used to perform the ablations. Refractive outcomes and wavefront data are reported up to 4 years after retreatment. Pre- and postoperative data were compared with Student t tests and (multivariate) correlation tests. P<.05 was considered statistically significant. A bilinear correlation of various postoperative wavefront aberrations versus planned correction and preoperative aberration was performed. RESULTS: Mean manifest refraction spherical equivalent (MRSE) before retreatment was -0.38±1.85 diopters (D) and -0.09±0.22 D at 6 months and -0.10±0.38 D at 4 years postoperatively. The reduction in MRSE was statistically significant at both postoperative time points (P<.005). Postoperative aberrations were statistically lower (spherical aberration P<.05; coma P<.005; root-mean-square higher order aberration P<.0001) at 4 years postoperatively. Distribution of the postoperative uncorrected distance visual acuity (P<.0001) and corrected distance visual acuity (P<.01) were statistically better than preoperative values. CONCLUSIONS: Aspheric corneal wavefront customization with the ESIRIS yields visual, optical, and refractive results comparable to those of other wavefront-guided customized techniques for the correction of myopia and myopic astigmatism. The corneal wavefront customized approach shows its strength in cases where abnormal optical systems are expected. Systematic wavefront customized corneal ablation appears safe and efficacious for retreatment cases.


Asunto(s)
Astigmatismo/cirugía , Aberración de Frente de Onda Corneal/cirugía , Queratomileusis por Láser In Situ , Láseres de Excímeros/uso terapéutico , Adulto , Astigmatismo/etiología , Topografía de la Córnea , Aberración de Frente de Onda Corneal/etiología , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Refracción Ocular/fisiología , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual/fisiología
19.
J Refract Surg ; 28(9): 657-63, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22947295

RESUMEN

PURPOSE: To describe and quantify the errors inherent to topography-guided ablation of irregular corneas due to natural epithelial thickness compensatory remodeling. METHODS: Artemis very high-frequency (VHF) digital ultrasound scanning (ArcScan Inc) was performed on a cornea that had undergone radial keratotomy with inferior and superior trapezoidal keratotomies, resulting 27 years later in high irregular astigmatism (+6.50 -8.00 × 101) and severe loss of corrected distance visual acuity (CDVA) to 20/50. The epithelial thickness profile was highly irregular, masking a significant proportion of the true stromal irregularity from front corneal surface topography, which would have resulted in significant inaccuracies had a topography-guided ablation been performed. The stromal ablation pattern of a transepithelial phototherapeutic keratectomy (PTK) ablation was modeled, which appeared logically to reduce the areas of abnormal stromal surface elevation and resembled a hyperopic astigmatic ablation of approximately 3.50 diopters of cylinder. Artemis-assisted transepithelial PTK was performed to target the stromal irregularity masked by epithelium. RESULTS: Artemis-assisted transepithelial PTK induced a refractive change similar to that predicted (+2.24 -3.97 × 120), demonstrating the refractive shift produced by the epithelium. The epithelial thickness profile became relatively regular and CDVA returned to 20/20⁻². Two topography wavefront-guided ablations were performed to correct the remaining topographic irregularity and refractive error, resulting in a near plano refraction, significantly lower higher order aberrations, and CDVA of 20/20⁺². CONCLUSIONS: A knowledge of stromal surface shape and power shift produced by epithelial thickness profile alterations after corneal surgery has the potential of improving the efficacy and safety of custom corneal ablation.


Asunto(s)
Sustancia Propia/diagnóstico por imagen , Topografía de la Córnea , Epitelio Corneal/diagnóstico por imagen , Errores de Refracción/diagnóstico por imagen , Astigmatismo/etiología , Astigmatismo/cirugía , Sustancia Propia/cirugía , Aberración de Frente de Onda Corneal/etiología , Aberración de Frente de Onda Corneal/cirugía , Humanos , Imagenología Tridimensional , Queratomileusis por Láser In Situ/métodos , Queratotomía Radial , Láseres de Excímeros/uso terapéutico , Masculino , Persona de Mediana Edad , Queratectomía Fotorrefractiva/métodos , Ultrasonografía , Agudeza Visual
20.
Klin Monbl Augenheilkd ; 229(11): 1108-12, 2012 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-22996631

RESUMEN

Further developments in the field of intraocular lenses have resulted in improvements of multifocal lenses (MIOL) which enable spectacle-free vision at near and far distance under most conditions. In our prospective study we investigated a new aberration-corrected MIOL, whereby 31 eyes of 19 patients, aged between 40 and 81 years, received a Tecnis ZMB00 MIOL (Abbott Medical Optics). Postoperative visual results were documented. Patients were enrolled if they were at least 40 years old and if they were scheduled for cataract surgery or presbyobic lens exchange. Exclusion criteria were any other visually relevant pathologies and a corneal astigmatism of 1.5 D or more. After 6 months, 94.7 % of the patients had a binocular uncorrected distance vision of 0.1 LogMAR or better, 67.7 % of eyes could read Jaeger 1+ (0.0 LogMAR) and 93.6 % could read Jaeger 1 (0.1 LogMAR) or better. There was no correlation between the power of the implanted lens and the postoperative distance or near vision or between IOL power and best-corrected distance vision. The aspheric diffractive multifocal IOL Tecnis ZMB00 provides a restoration of far and near visual function after cataract surgery or presbyopia correction. The correction provided by the IOL is predictable and independent from the optical power of the IOL implanted. The combination of diffractive multifocality and compensation for corneal spherical aberration is an effective alternative for cataract surgery and presbyopia correction.


Asunto(s)
Aberración de Frente de Onda Corneal/cirugía , Lentes Intraoculares , Presbiopía/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Aberración de Frente de Onda Corneal/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Oftalmoscopios , Oftalmoscopía , Fenómenos Ópticos , Complicaciones Posoperatorias/diagnóstico , Estudios Prospectivos , Diseño de Prótesis , Tonometría Ocular , Pruebas de Visión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA