Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Anal Chem ; 96(25): 10322-10331, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38801718

RESUMEN

The chemical information on brain science provided by electrochemical sensors is critical for understanding brain chemistry during physiological and pathological processes. A major challenge is the selectivity of electrochemical sensors in vivo. This work developed a universal covalent grafting strategy of an aptamer on a carbon fiber microelectrode (CFE) for selective determination of dopamine in vivo. The universal strategy was proposed by oxidizing poly(tannic acid) (pTA) to form an oxidized state (pTAox) and then coupling a nucleophilic sulfhydryl molecule of the dopamine-binding mercapto-aptamer with the o-quinone moiety of pTAox based on click chemistry for the interfacial functionalization of the CFE surface. It was found that the universal strategy proposed could efficiently graft the aptamer on a glassy carbon electrode, which was verified by using electroactive 6-(ferrocenyl) hexanethiol as a redox reporter. The amperometric method using a fabricated aptasensor for the determination of dopamine was developed. The linear range of the aptasensor for the determination of dopamine was 0.2-20 µM with a sensitivity of 0.09 nA/µM and a limit of detection of 88 nM (S/N = 3). The developed method has high selectivity originating from the specific recognition of the aptamer in concert with the cation-selective action of pTA and could be easily applicable to probe dopamine dynamics in the brain. Furthermore, complex vesicle fusion modes were first observed at the animal level. This work demonstrated that the covalently grafted immobilization strategy proposed is promising and could be extended to the in vivo analysis of other neurochemicals.


Asunto(s)
Aptámeros de Nucleótidos , Fibra de Carbono , Dopamina , Microelectrodos , Dopamina/análisis , Aptámeros de Nucleótidos/química , Fibra de Carbono/química , Animales , Técnicas Electroquímicas/métodos , Carbono/química , Ratas , Técnicas Biosensibles/métodos , Masculino , Oxidación-Reducción
2.
Anal Biochem ; 695: 115640, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39142532

RESUMEN

The development of integrated analytical devices is crucial for advancing next-generation point-of-care platforms. Herein, we describe a facile synthesis of a strongly catalytic and durable Nitrogen-doped graphene oxide decorated platinum cobalt (NGO-PtCo) nanocomposite that is conjugated with target-specific DNA aptamer (i-e. MUC1) and grown on carbon fiber. Benefitting from the combined features of the high electrochemical surface area of N-doped GO, high capacitance and stabilization by Co, and high kinetic performance by Pt, a robust, multifunctional, and flexible nanotransducer surface was created. The designed platform was applied for the specific detection of a blood-based oncomarker, CA15-3. The electrochemical characterization proved that nanosurface provides a highly conductive and proficient immobilization support with a strong bio-affinity towards MUC1 aptamer. The specific interaction between CA15-3 and the aptamer alters the surface properties of the aptasensor and the electroactive signal probe generated a remarkable increase in signal intensity. The sensor exhibited a wide dynamic range of 5.0 × 10-2 -200 U mL-1, a low limit of detection (LOD) of 4.1 × 10-2 U mL-1, and good reproducibility. The analysis of spiked serum samples revealed outstanding recoveries of up to 100.03 %, by the proposed aptasensor. The aptasensor design opens new revelations in the reliable detection of tumor biomarkers for timely cancer diagnosis.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Fibra de Carbono , Cobalto , Técnicas Electroquímicas , Grafito , Mucina-1 , Nanocompuestos , Platino (Metal) , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Grafito/química , Humanos , Mucina-1/sangre , Mucina-1/análisis , Cobalto/química , Nanocompuestos/química , Platino (Metal)/química , Técnicas Biosensibles/métodos , Fibra de Carbono/química , Límite de Detección
3.
Analyst ; 149(18): 4643-4652, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39136087

RESUMEN

The sensitivity of zinc (Zn(II)) detection using fast-scan cyclic voltammetry (FSCV) with carbon fiber microelectrodes (CFMEs) is low compared to other neurochemicals. We have shown previously that Zn(II) plates to the surface of CFME's and we speculate that it is because of the abundance of oxide functionality on the surface. Plating reduces sensitivity over time and causes significant disruption to detection stability. This limited sensitivity and stability hinders Zn(II) detection, especially in complex matrices like the brain. To address this, we developed plasma-treated gold fiber microelectrodes (AuMEs) which enable sensitive and stable Zn(II) detection with FSCV. Typically, gold fibers are treated using corrosive acids to clean the surface and this step is important for preparing the surface for electrochemistry. Likewise, because FSCV is an adsorption-based technique, it is also important for Zn(II) to adsorb and desorb to prevent irreversible plating. Because of these requirements, careful optimization of the electrode surface was necessary to render the surface for Zn(II) adsorption yet strike a balance between attraction to the surface vs. irreversible interactions. In this study, we employed oxygen plasma treatment to activate the gold fiber surface without inducing significant morphological changes. This treatment effectively removes the organic layer while functionalizing the surface with oxygen, enabling Zn(II) detection that is not possible on untreated gold surfaces. Our results demonstrate significantly improved Zn(II) detection sensitivity and stability on AuME compared to CFME's. Overall, this work provides an advance in our understanding of Zn(II) electrochemistry and a new tool for improved metallotransmitter detection in the brain.


Asunto(s)
Técnicas Electroquímicas , Oro , Microelectrodos , Zinc , Zinc/química , Oro/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Fibra de Carbono/química , Gases em Plasma/química , Carbono/química , Adsorción , Oxígeno/química
4.
Analyst ; 149(10): 3008-3016, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38606455

RESUMEN

Fast-scan cyclic voltammetry (FSCV) is a widely used technique for detecting neurotransmitters. However, electrode fouling can negatively impact its accuracy and sensitivity. Fouling refers to the accumulation of unwanted materials on the electrode surface, which can alter its electrochemical properties and reduce its sensitivity and selectivity. Fouling mechanisms can be broad and may include biofouling, the accumulation of biomolecules on the electrode surface, and chemical fouling, the deposition of unwanted chemical species. Despite individual studies discussing fouling effects on either the working electrode or the reference electrode, no comprehensive study has been conducted to compare the overall fouling effects on both electrodes in the context of FSCV. Here, we examined the effects of biofouling and chemical fouling on the carbon fiber micro-electrode (CFME) as the working electrode and the Ag/AgCl reference electrode with FSCV. Both fouling mechanisms significantly decreased the sensitivity and caused peak voltage shifts in the FSCV signal with the CFME, but not with the Ag/AgCl reference electrode. Interestingly, previous studies have reported peak voltage shifts in FSCV signals due to the fouling of Ag/AgCl electrodes after implantation in the brain. We noticed in a previous study that energy-dispersive spectroscopy (EDS) spectra showed increased sulfide ion concentration after implantation. We hypothesized that sulfide ions may be responsible for the peak voltage shift. To test this hypothesis, we added sulfide ions to the buffer solution, which decreased the open circuit potential of the Ag/AgCl electrode and caused a peak voltage shift in the FSCV voltammograms. Also, EDS analysis showed that sulfide ion concentration increased on the surface of the Ag/AgCl electrodes after 3 weeks of chronic implantation, necessitating consideration of sulfide ions as the fouling agent for the reference electrodes. Overall, our study provides important insights into the mechanisms of electrode fouling and its impact on FSCV measurements. These findings could inform the design of FSCV experiments, with the development of new strategies for improving the accuracy and reliability of FSCV measurements in vivo.


Asunto(s)
Incrustaciones Biológicas , Técnicas Electroquímicas , Neurotransmisores , Neurotransmisores/análisis , Incrustaciones Biológicas/prevención & control , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Animales , Compuestos de Plata/química , Fibra de Carbono/química , Microelectrodos , Sulfuros/química , Electrodos
5.
Analyst ; 149(19): 4915-4921, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39143937

RESUMEN

Baijiu, a traditional Chinese alcoholic beverage, carries China's rich historical and cultural heritage. Consumers experience varying levels of relaxation and pleasure after consuming different types of Baijiu, with the biological basis of delectation influenced by serotonin and dopamine. In this study, we prepared carbon fiber electrodes modified with surface decorated gold nanoparticles to directly measure the electrochemical response signals in the serum of mice before and after gavage with different types of Baijiu. It was observed that the serum signal change in mice after consuming Baijiu sample 1 (J1) was higher than that of the other two types of Baijiu. Consequently, trace flavor compounds in the Baijiu samples were detected using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS), revealing the highest content of L-lactic acid in J1. Mice were intraperitoneally injected with 200 mg kg-1 of L-lactic acid. The changes in dopamine and serotonin in the serum of the injected mice were monitored using a biosensor, and the results were compared with the results of high performance liquid chromatography-triple quadrupole mass spectrometry (HPLC-MS). The findings confirmed that L-lactic acid could indeed stimulate the secretion of both neurotransmitters in mice, suggesting that the trace components in J1 may even exhibit synergistic effects. This study contributes to a deeper understanding of the effects of Baijiu on the body and provides a scientific basis for the production and consumption of Baijiu.


Asunto(s)
Dopamina , Técnicas Electroquímicas , Ácido Láctico , Serotonina , Animales , Dopamina/sangre , Dopamina/metabolismo , Serotonina/metabolismo , Serotonina/sangre , Ratones , Técnicas Electroquímicas/métodos , Ácido Láctico/sangre , Ácido Láctico/química , Ácido Láctico/análisis , Oro/química , Bebidas Alcohólicas/análisis , Nanopartículas del Metal/química , Masculino , Electrodos , Técnicas Biosensibles/métodos , Fibra de Carbono/química
6.
Anal Bioanal Chem ; 416(21): 4807-4818, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38914733

RESUMEN

The hormone Neuropeptide Y (NPY) plays critical roles in feeding, satiety, obesity, and weight control. However, its complex peptide structure has hindered the development of fast and biocompatible detection methods. Previous studies utilizing electrochemical techniques with carbon fiber microelectrodes (CFMEs) have targeted the oxidation of amino acid residues like tyrosine to measure peptides. Here, we employ the modified sawhorse waveform (MSW) to enable voltammetric identification of NPY through tyrosine oxidation. Use of MSW improves NPY detection sensitivity and selectivity by reducing interference from catecholamines like dopamine, serotonin, and others compared to the traditional triangle waveform. The technique utilizes a holding potential of -0.2 V and a switching potential of 1.2 V that effectively etches and renews the CFME surface to simultaneously detect NPY and other monoamines with a sensitivity of 5.8 ± 0.94 nA/µM (n = 5). Furthermore, we observed adsorption-controlled, subsecond NPY measurements with CFMEs and MSW. The effective identification of exogenously applied NPY in biological fluids demonstrates the feasibility of this methodology for in vivo and ex vivo studies. These results highlight the potential of MSW voltammetry to enable fast, biocompatible NPY quantification to further elucidate its physiological roles.


Asunto(s)
Técnicas Electroquímicas , Neuropéptido Y , Neuropéptido Y/análisis , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Microelectrodos , Humanos , Oxidación-Reducción , Fibra de Carbono/química , Tirosina/análisis , Tirosina/química , Animales
7.
Environ Res ; 252(Pt 1): 118881, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38582430

RESUMEN

Nitrate reduction in bio-electrochemical systems (BESs) has attracted wide attention due to its low sludge yields and cost-efficiency advantages. However, the high resistance of traditional electrodes is considered to limit the denitrification performance of BESs. Herein, a new graphene/polypyrrole (rGO/PPy) modified electrode is fabricated via one-step electrodeposition and used as cathode in BES for improving nitrate removal from wastewater. The formation and morphological results support the successful formation of rGO/PPy nanohybrids and confirm the part covalent bonding of Py into GO honeycomb lattices to form a three-dimensional cross-linked spatial structure. The electrochemical tests indicate that the rGO/PPy electrode outperforms the unmodified electrode due to the 3.9-fold increase in electrochemical active surface area and 6.9-fold decrease in the charge transfer resistance (Rct). Batch denitrification activity tests demonstrate that the BES equipped with modified rGO/PPy biocathode could not only achieve the full denitrification efficiency of 100% with energy recovery (15.9 × 10-2 ± 0.14 A/m2), but also favor microbial attach and growth with improved biocompatible surface. This work provides a feasible electrochemical route to fabricate and design a high-performance bioelectrode to enhance denitrification in BESs.


Asunto(s)
Desnitrificación , Electrodos , Grafito , Polímeros , Pirroles , Grafito/química , Polímeros/química , Pirroles/química , Técnicas Electroquímicas/métodos , Fuentes de Energía Bioeléctrica , Nitratos/química , Carbono/química , Fibra de Carbono/química
8.
Environ Res ; 249: 118254, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38301762

RESUMEN

The electro-Fenton (EF) based on gas-diffusion electrodes (GDEs) reveals promising application prospective towards recalcitrant organics degradation because such GDEs often yields superior H2O2 generation efficiency and selectivity. However, the low efficiency of Fe2+/Fe3+ cycle with GDEs is always considered to be the limiting step for the EF process. In this study, activated carbon fiber (ACF) was firstly employed as co-catalyst to facilitate the performance of antibiotic cefaclor (CEC) decomposition in EF process. It was found that the addition of ACF co-catalyst achieved a rapid Fe2+/Fe3+ cycling, which significantly enhanced Fenton's reaction and hydroxyl radicals (•OH) generation. X-ray photoelectron spectroscopy (XPS) results indicated that the functional groups on ACF surface are related to the conversion of Fe3+ into Fe2+. Moreover, DMSO probing experiment confirmed the enhanced •OH production in EF + ACF system compared to conventional EF system. When inactive BDD and Ti4O7/Ti anodes were paired to EF system, the addition of ACF could significantly improve mineralization degree. However, a large amount of toxic byproducts, including chlorate (ClO3-) and perchlorate (ClO4-), were generated in these EF processes, especially for BDD anode, due to their robust oxidation capacity. Higher mineralization efficiency and less toxic ClO4- generation were obtained in the EF + ACF process with Ti4O7/Ti anode. This presents a novel alternative for efficient chloride-containing organic removal during wastewater remediation.


Asunto(s)
Antibacterianos , Fibra de Carbono , Cefaclor , Electrodos , Peróxido de Hidrógeno , Hierro , Contaminantes Químicos del Agua , Fibra de Carbono/química , Antibacterianos/química , Peróxido de Hidrógeno/química , Contaminantes Químicos del Agua/química , Hierro/química , Cefaclor/química , Catálisis , Carbón Orgánico/química , Técnicas Electroquímicas/métodos
9.
J Nanobiotechnology ; 22(1): 377, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937768

RESUMEN

BACKGROUND: Efficient monitoring of glucose concentration in the human body necessitates the utilization of electrochemically active sensing materials in nonenzymatic glucose sensors. However, prevailing limitations such as intricate fabrication processes, lower sensitivity, and instability impede their practical application. Herein, ternary Cu-Co-Ni-S sulfides nanoporous network structure was synthesized on carbon fiber paper (CP) by an ultrafast, facile, and controllable technique through on-step cyclic voltammetry, serving as a superior self-supporting catalytic electrode for the high-performance glucose sensor. RESULTS: The direct growth of free-standing Cu-Co-Ni-S on the interconnected three-dimensional (3D) network of CP boosted the active site of the composites, improved ion diffusion kinetics, and significantly promoted the electron transfer rate. The multiple oxidation states and synergistic effects among Co, Ni, Cu, and S further promoted glucose electrooxidation. The well-architected Cu-Co-Ni-S/CP presented exceptional electrocatalytic properties for glucose with satisfied linearity of a broad range from 0.3 to 16,000 µM and high sensitivity of 6829 µA mM- 1 cm- 2. Furthermore, the novel sensor demonstrated excellent selectivity and storage stability, which could successfully evaluate the glucose levels in human serum. Notably, the novel Cu-Co-Ni-S/CP showed favorable biocompatibility, proving its potential for in vivo glucose monitoring. CONCLUSION: The proposed 3D hierarchical morphology self-supported electrode sensor, which demonstrates appealing analysis behavior for glucose electrooxidation, holds great promise for the next generation of high-performance glucose sensors.


Asunto(s)
Técnicas Biosensibles , Fibra de Carbono , Cobalto , Cobre , Técnicas Electroquímicas , Electrodos , Níquel , Sulfuros , Cobre/química , Níquel/química , Catálisis , Humanos , Cobalto/química , Técnicas Electroquímicas/métodos , Técnicas Biosensibles/métodos , Sulfuros/química , Fibra de Carbono/química , Glucosa/análisis , Glucosa/química , Nanoporos , Oxidación-Reducción , Glucemia/análisis
10.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38795258

RESUMEN

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Asunto(s)
Benzofenonas , Coronas , Pilares Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Titanio , Circonio , Cetonas/química , Polietilenglicoles/química , Humanos , Circonio/química , Titanio/química , Fibra de Carbono/química , Diseño de Implante Dental-Pilar , Incisivo , Materiales Dentales/química , Implantes Dentales de Diente Único , Hueso Cortical , Vidrio/química , Diseño de Prótesis Dental
11.
Int J Mol Sci ; 25(15)2024 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-39126084

RESUMEN

Nowadays, owing to the new technological and industrial requirements for equipment, such as flexibility or multifunctionally, the development of all-solid-state supercapacitors and Li-ion batteries has become a goal for researchers. For these purposes, the composite material approach has been widely proposed due to the promising features of woven carbon fiber as a substrate material for this type of material. Carbon fiber displays excellent mechanical properties, flexibility, and high electrical conductivity, allowing it to act as a substrate and a collector at the same time. However, carbon fiber's energy-storage capability is limited. Several coatings have been proposed for this, with nanostructured transition metal oxides being one of the most popular due to their high theoretical capacity and surface area. In this overview, the main techniques used to achieve these coatings-such as solvothermal synthesis, MOF-derived obtention, and electrochemical deposition-are summarized, as well as the main strategies for alleviating the low electrical conductivity of transition metal oxides, which is the main drawback of these materials.


Asunto(s)
Fibra de Carbono , Capacidad Eléctrica , Suministros de Energía Eléctrica , Electrodos , Litio , Nanoestructuras , Óxidos , Litio/química , Fibra de Carbono/química , Óxidos/química , Nanoestructuras/química , Elementos de Transición/química , Conductividad Eléctrica , Metales/química
12.
Angew Chem Int Ed Engl ; 63(36): e202407063, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-38898543

RESUMEN

Developing real-time, dynamic, and in situ analytical methods with high spatial and temporal resolutions is crucial for exploring biochemical processes in the brain. Although in vivo electrochemical methods based on carbon fiber (CF) microelectrodes are effective in monitoring neurochemical dynamics during physiological and pathological processes, complex post modification hinders large-scale productions and widespread neuroscience applications. Herein, we develop a general strategy for the in situ engineering of carbon-based materials to mass-produce functional CFs by introducing polydopamine to anchor zeolitic imidazolate frameworks as precursors, followed by one-step pyrolysis. This strategy demonstrates exceptional universality and design flexibility, overcoming complex post-modification procedures and avoiding the delamination of the modification layer. This simplifies the fabrication and integration of functional CF-based microelectrodes. Moreover, we design highly stable and selective H+, O2, and ascorbate microsensors and monitor the influence of CO2 exposure on the O2 content of the cerebral tissue during physiological and ischemia-reperfusion pathological processes.


Asunto(s)
Fibra de Carbono , Carbono , Fibra de Carbono/química , Carbono/química , Técnicas Electroquímicas/métodos , Polímeros/química , Animales , Indoles/química , Microelectrodos , Ácido Ascórbico/química , Oxígeno/química , Oxígeno/metabolismo , Zeolitas/química , Imidazoles/química , Dióxido de Carbono/química
13.
Macromol Rapid Commun ; 44(4): e2200738, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36494320

RESUMEN

Owing to their excellent physical and chemical properties, the carbon fibre reinforced poly(ether-ether-ketone) composites (CF/PEEK) are widely used in aerospace applications such as rockets, missiles, and high-speed vehicles. However, both carbon fibre (CF) and poly(ether-ether-ketone) (PEEK) have inert molecular chain structures, which seriously affect the interfacial properties of CF/PEEK composites. In this study, to improve the properties of CF/PEEK composites, carboxylated PEEK (PEEK-COOH) with different carboxylation degrees is synthesized as the sizing agent by a "two-step" method. Then, the activated CF surface is coated by PEEK-COOH sizing layers with different functionalization degrees to prepare the CF/PEEK composites. The results show that the interfacial properties of CF/PEEK composites are improved after applying the sizing agent. When the carboxylation degree of PEEK-COOH is 19.61%, the flexural strength, flexural modulus, and interlaminar shear strength (ILSS) of CF/PEEK composites reach 489.34 MPa, 25.387 GPa, and 81.3 MPa, respectively. In addition, the use of PEEK-COOH sizing agents can form an excellent transition layer between CF and PEEK, creating an efficient stress transfer system and facilitating an even stress distribution between CF and PEEK. Furthermore, the main mechanism of material fracture changes from CF debonding to CF and resin fracture.


Asunto(s)
Cetonas , Polímeros , Fibra de Carbono/química , Ensayo de Materiales , Polímeros/química , Cetonas/química
14.
Skeletal Radiol ; 52(3): 393-404, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35536358

RESUMEN

Carbon-fiber-reinforced polyetheretherketone (CFR-PEEK) orthopedic implants are gaining popularity in oncologic applications as they offer many potential advantages over traditional metallic implants. From an imaging perspective, this instrumentation allows for improved evaluation of adjacent anatomic structures during radiography, computed tomography (CT), and magnetic resonance imaging (MRI). This results in improved postoperative surveillance imaging quality as well as easier visualization of anatomy for potential image-guided percutaneous interventions (e.g., pain palliation injections, or ablative procedures for local disease control). CFR-PEEK devices are also advantageous in radiation oncology treatment due to their decreased imaging artifact during treatment planning imaging and decreased dose perturbation during radiotherapy delivery. As manufacturing processes for CFR-PEEK materials continue to evolve and improve, potential orthopedic applications in the spine and appendicular skeleton increase. An understanding of the unique properties of CFR-PEEK devices and their impact on imaging is valuable to radiologists delivering care to orthopedic oncology patients in both the diagnostic and interventional settings. This multidisciplinary review aims to provide a comprehensive insight into the radiologic, surgical, and radiation oncology impact of these innovative devices.


Asunto(s)
Neoplasias de la Columna Vertebral , Humanos , Fibra de Carbono/química , Neoplasias de la Columna Vertebral/cirugía , Polímeros , Benzofenonas , Polietilenglicoles/química , Cetonas/química , Carbono/química
15.
Anal Chem ; 94(11): 4803-4812, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35274933

RESUMEN

Here, we have synthesized and characterized graphene-fiber microelectrodes (GFME's) for subsecond detection of neurochemicals with fast-scan cyclic voltammetry (FSCV) for the first time. GFME's exhibited extraordinary properties including faster electron transfer kinetics, significantly improved sensitivity, and ease of tunability that we anticipate will have major impacts on neurochemical detection for years to come. GF's have been used in the literature for various applications; however, scaling their size down to microelectrodes and implementing them as neurochemical microsensors is significantly less developed. The GF's developed in this paper were on average 20-30 µm in diameter and both graphene oxide (GO) and reduced graphene oxide (rGO) fibers were characterized with FSCV. Neat GF's were synthesized using a one-step dimension-confined hydrothermal strategy. FSCV detection has traditionally used carbon-fiber microelectrodes (CFME's) and more recently carbon nanotube fiber electrodes; however, uniform functionalization and direct control of the 3D surface structure of these materials remain limited. The expansion to GFME's will certainly open new avenues for fine-tuning the electrode surface for specific electrochemical detection. When comparing to traditional CFME's, our GFME's exhibited significant increases in electron transfer, redox cycling, fouling resistance, higher sensitivity, and frequency independent behavior which demonstrates their incredible utility as biological sensors.


Asunto(s)
Grafito , Nanotubos de Carbono , Fibra de Carbono/química , Dopamina/química , Microelectrodos , Nanotubos de Carbono/química
16.
Faraday Discuss ; 233(0): 336-353, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-34935021

RESUMEN

Fundamental insight into the extent to which the nanostructured surface and geometry impacts neurochemical interactions at electrode surfaces could provide significant advances in our ability to design and fabricate ultrasensitive neurochemical detection probes. Here, we investigate the extent to which the nanostructure of the carbon-fiber surface impacts detection of catecholamines and purines with fast-scan cyclic voltammetry (FSCV). Carbon-fibers were treated with argon (Ar) plasma to induce variations in the nano- and micro-structure without changing the functionalization of the surface. We tested variations in topology by measuring the extent to which the flow rate, RF power, and treatment time affect the surface roughness. Flow rates from 50-100 sccm, plasma power from 20-100 W, and treatment times from 30 s to 5 min were compared. Two Ar-treatments were chosen from the optimization studies for comparison, and the surface roughness was evaluated using atomic force microscopy (AFM). To ensure no changes in chemical composition, fibers were analyzed with X-ray photoelectron spectroscopy (XPS). On average, at the optimized Ar-plasma treatment procedure, oxidative current for adenosine and ATP increased by 3.5 ± 1.4-fold and 3.2 ± 0.6-fold, and guanosine and GTP by 1.7 ± 0.3-fold and 1.8 ± 0.3-fold, respectively (n = 9). Dopamine increased by 1.7 ± 0.3-fold. The extent to which changes in the electrode structure impact adsorption, sensitivity, and electron transfer rates were measured. A COMSOL Multiphysics simulation was developed to enable the modeling of mass transport of electroactive species at varying electrode geometries. Overall, this study provides critical insight into the extent to which the nanostructure of the surface impacts the electrochemical detection of neurochemicals.


Asunto(s)
Dopamina , Nanoestructuras , Fibra de Carbono/química , Electrodos , Microscopía de Fuerza Atómica
17.
Molecules ; 27(2)2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35056837

RESUMEN

Direct in vivo measurements of neurometabolic markers in the brain with high spatio-temporal resolution, sensitivity, and selectivity is highly important to understand neurometabolism. Electrochemical biosensors based on microelectrodes are very attractive analytical tools for continuous monitoring of neurometabolic markers, such as lactate and glucose in the brain extracellular space at resting and following neuronal activation. Here, we assess the merits of a platinized carbon fiber microelectrode (CFM/Pt) as a sensing platform for developing enzyme oxidase-based microbiosensors to measure extracellular lactate in the brain. Lactate oxidase was immobilized on the CFM/Pt surface by crosslinking with glutaraldehyde. The CFM/Pt-based lactate microbiosensor exhibited high sensitivity and selectivity, good operational stability, and low dependence on oxygen, temperature, and pH. An array consisting of a glucose and lactate microbiosensors, including a null sensor, was used for concurrent measurement of both neurometabolic substrates in vivo in the anesthetized rat brain. Rapid changes of lactate and glucose were observed in the cortex and hippocampus in response to local glucose and lactate application and upon insulin-induced fluctuations of systemic glucose. Overall, these results indicate that microbiosensors are a valuable tool to investigate neurometabolism and to better understand the role of major neurometabolic markers, such as lactate and glucose.


Asunto(s)
Técnicas Biosensibles/instrumentación , Encéfalo/metabolismo , Glucosa/análisis , Ácido Láctico/análisis , Oxigenasas de Función Mixta/metabolismo , Animales , Fibra de Carbono/química , Técnicas Electroquímicas , Enzimas Inmovilizadas/metabolismo , Glucosa/metabolismo , Ácido Láctico/metabolismo , Masculino , Microelectrodos , Ratas , Ratas Wistar
18.
Anal Chem ; 93(2): 973-980, 2021 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-33297678

RESUMEN

Aptamer-modified microelectrodes for Neuropeptide Y measurement by electrochemical impedance spectroscopy was described here. The advantages of using carbon fiber or platinum microelectrodes are because they are promising materials with high electrical conductivity, chemical stability, and high surface area that can be easily modified on their surface. The immobilization and biofouling were studied and compared using EIS. Moreover, the adsorption of NPY to the aptamer-modified microelectrodes was also demonstrated by EIS. Changes of -ω*Zimag, an impedance factor that gives information of the capacitance, is directly correlated with concentrations. A widely linear range was obtained from 10 to 1000 ng/mL of NPY. This method was able to detect NPY without performing a redox reaction by adsorption at the surface of the microelectrodes, with the specificity provided by aptamer functionalization of the microelectrode surface.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Biosensibles , Espectroscopía Dieléctrica , Neuropéptido Y/análisis , Fibra de Carbono/química , Microelectrodos , Platino (Metal)/química , Propiedades de Superficie
19.
Int J Mol Sci ; 22(22)2021 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-34830128

RESUMEN

A biomaterial that is both bioactive and capable of controlled drug release is highly attractive for bone regeneration. In previous works, we demonstrated the possibility of combining activated carbon fiber cloth (ACC) and biomimetic apatite (such as calcium-deficient hydroxyapatite (CDA)) to develop an efficient material for bone regeneration. The aim to use the adsorption properties of an activated carbon/biomimetic apatite composite to synthetize a biomaterial to be used as a controlled drug release system after implantation. The adsorption and desorption of tetracycline and aspirin were first investigated in the ACC and CDA components and then on ACC/CDA composite. The results showed that drug adsorption and release are dependent on the adsorbent material and the drug polarity/hydrophilicity, leading to two distinct modes of drug adsorption and release. Consequently, a double adsorption approach was successfully performed, leading to a multifunctional and innovative ACC-aspirin/CDA-tetracycline implantable biomaterial. In a second step, in vitro tests emphasized a better affinity of the drug (tetracycline or aspirin)-loaded ACC/CDA materials towards human primary osteoblast viability and proliferation. Then, in vivo experiments on a large cortical bone defect in rats was carried out to test biocompatibility and bone regeneration ability. Data clearly highlighted a significant acceleration of bone reconstruction in the presence of the ACC/CDA patch. The ability of the aspirin-loaded ACC/CDA material to release the drug in situ for improving bone healing was also underlined, as a proof of concept. This work highlights the possibility of bone patches with controlled (multi)drug release features being used for bone tissue repair.


Asunto(s)
Apatitas/química , Aspirina/administración & dosificación , Materiales Biomiméticos/química , Fibra de Carbono/química , Sistemas de Liberación de Medicamentos/métodos , Tetraciclina/administración & dosificación , Adsorción , Animales , Antibacterianos/administración & dosificación , Antibacterianos/química , Antibacterianos/farmacocinética , Antiinflamatorios no Esteroideos/administración & dosificación , Antiinflamatorios no Esteroideos/química , Antiinflamatorios no Esteroideos/farmacocinética , Aspirina/química , Aspirina/farmacocinética , Regeneración Ósea/efectos de los fármacos , Sustitutos de Huesos/química , Huesos/metabolismo , Carbón Orgánico/química , Liberación de Fármacos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Tetraciclina/química , Tetraciclina/farmacocinética
20.
Molecules ; 26(3)2021 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-33573267

RESUMEN

To improve the properties of mesoporous carbon (MC), used as a catalyst support within electrodes, MC fibers (MCFs) were successfully synthesized by combining organic-organic self-assembly and electrospinning deposition and optimizing heat treatment conditions. The pore structure was controlled by varying the experimental conditions. Among MCFs, MCF-A, which was made in the most acidic condition, resulted in the largest pore diameter (4-5 nm), and the porous structure and carbonization degree were further optimized by adjusting heat treatment conditions. Then, since the fiber structure is expected to have an advantage when MCFs are applied to devices, MCF-A layers were prepared by spray printing. For the resistance to compression, MCF-A layers showed higher resistance (5.5% change in thickness) than the bulk MC layer (12.8% change in thickness). The through-plane resistance was lower when the fiber structure remained more within the thin layer, for example, +8 mΩ for 450 rpm milled MCF-A and +12 mΩ for 800 rpm milled MCF-A against the gas diffusion layer (GDL) 25BC carbon paper without a carbon layer coating. The additional advantages of MCF-A compared with bulk MC demonstrate that MCF-A has the potential to be used as a catalyst support within electrodes in energy devices.


Asunto(s)
Fibra de Carbono/química , Carbono/química , Nanoestructuras/química , Catálisis , Electrodos , Humanos , Porosidad , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA