Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Intervalo de año de publicación
1.
Malar J ; 21(1): 9, 2022 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-34986840

RESUMEN

BACKGROUND: Malaria incidence has declined in Ethiopia in the past 10 years. Current malaria diagnostic tests, including light microscopy and rapid antigen-detecting diagnostic tests (RDTs) cannot reliably detect low-density infections. Studies have shown that nucleic acid amplification tests are highly sensitive and specific in detecting malaria infection. This study took place with the aim of evaluating the performance of multiplex real time PCR for the diagnosis of malaria using patient samples collected from health facilities located at malaria elimination targeted low transmission settings in Ethiopia. METHODS: A health facility-based, cross-sectional survey was conducted in selected malaria sentinel sites. Malaria-suspected febrile outpatients referred to laboratory for malaria testing between December 2019 and March 2020 was enrolled into this study. Sociodemographic information and capillary blood samples were collected from the study participants and tested at spot with RDTs. Additionally, five circles of dry blood spot (DBS) samples on Whatman filter paper and thick and thin smear were prepared for molecular testing and microscopic examination, respectively. Multiplex real time PCR assay was performed at Ethiopian Public Health Institute (EPHI) malaria laboratory. The performance of multiplex real time PCR assay, microscopy and RDT for the diagnosis of malaria was compared and evaluated against each other. RESULTS: Out of 271 blood samples, multiplex real time PCR identified 69 malaria cases as Plasmodium falciparum infection, 16 as Plasmodium vivax and 3 as mixed infections. Of the total samples, light microscopy detected 33 as P. falciparum, 18 as P. vivax, and RDT detected 43 as P. falciparum, 17 as P. vivax, and one mixed infection. Using light microscopy as reference test, the sensitivity and specificity of multiplex real time PCR were 100% (95% CI (93-100)) and 83.2% (95% CI (77.6-87.9)), respectively. Using multiplex real time PCR as a reference, light microscopy and RDT had sensitivity of 58% (95% CI 46.9-68.4) and 67% (95% CI 56.2-76.7); and 100% (95% CI 98-100) and 98.9% (95% CI 96-99.9), respectively. Substantial level of agreement was reported between microscopy and multiplex real time PCR results with kappa value of 0.65. CONCLUSIONS: Multiplex real-time PCR had an advanced performance in parasite detection and species identification on febrile patients' samples than did microscopy and RDT in low malaria transmission settings. It is highly sensitive malaria diagnostic method that can be used in malaria elimination programme, particularly for community based epidemiological samples. Although microscopy and RDT had reduced performance when compared to multiplex real time PCR, still had an acceptable performance in diagnosis of malaria cases on patient samples at clinical facilities.


Asunto(s)
Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Malaria Falciparum/diagnóstico , Malaria Vivax/diagnóstico , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Reacción en Cadena en Tiempo Real de la Polimerasa/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Estudios Transversales , Etiopía , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Plasmodium falciparum/aislamiento & purificación , Plasmodium vivax/aislamiento & purificación , Sensibilidad y Especificidad , Adulto Joven
2.
Malar J ; 20(1): 133, 2021 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-33676502

RESUMEN

BACKGROUND: Rapid and sensitive diagnostics are critical tools for clinical case management and public health control efforts. Both capillary and venous blood are currently used for malaria detection and while diagnostic technologies may not be equally sensitive with both materials, the published data on this subject are scarce and not conclusive. METHODS: Paired clinical samples of venous and capillary blood from 141 febrile individuals in Bo, Sierra Leone, were obtained between January and May 2019 and tested for the presence of Plasmodium parasites using two multiplexed PCR assays: the FilmArray-based Global Fever Panel (GFP) and the TaqMan-based Malaria Multiplex Sample Ready (MMSR) assay. RESULTS: No significant differences in Plasmodium parasite detection between capillary and venous blood for both assays were observed. The GFP assay was more sensitive than MMSR for all markers that could be compared (Plasmodium spp. and Plasmodium falciparum) in both venous and capillary blood. CONCLUSIONS: No difference was found in malaria detection between venous and capillary blood using two different PCR-based detection assays. This data gives support for use of capillary blood, a material which can be obtained easier by less invasive methods, for PCR-based malaria diagnostics, independent of the platform.


Asunto(s)
Capilares/parasitología , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Malaria/diagnóstico , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Plasmodium/aislamiento & purificación , Venas/parasitología , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Sierra Leona , Especificidad de la Especie , Adulto Joven
3.
Crit Care ; 24(1): 378, 2020 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-32586347

RESUMEN

BACKGROUND: The use of multiplex PCR to shorten time to identification of pathogens and their resistance mechanisms for patients with ventilator-associated pneumonia (VAP) is attractive, but poorly studied. The multiplex PCR-based Unyvero pneumonia cartridge assay can directly identify 20 bacteria and one fungus, amongst the most frequently causing VAP, and 19 of their resistance markers in clinical specimens (bronchoalveolar lavage or tracheal aspirate), with a turnaround time of 4-5 h. We performed this study to evaluate the concordance between the multiplex PCR-based Unyvero pneumonia cartridge assay and conventional microbiological techniques to identify pathogens and their resistance mechanisms in patients with VAP. METHODS: All patients suspected of having VAP (January 2016 to January 2019), who underwent fiberoptic bronchoscopy with bronchoalveolar lavage fluid (BALF) and whose BALF microscopy examination revealed intracellular bacteria, were included. BALF conventional cultures (gold standard), antimicrobial susceptibility testing and processing for the Unyvero pneumonia cartridge were done. Culture and Unyvero results were compared. RESULTS: Compared to cultures of the 93 samples processed for both techniques, Unyvero correctly identified pathogens in 68 (73%) proven VAP episodes, was discordant for 25 (27%), detected no pathogen in 11 and overdetected a not otherwise found pathogen in six. For the eight remaining discordant results, the pathogen responsible for VAP was not included in the Unyvero cartridge panel or it grew at a non-significant level in culture. Amongst the 31 (33%) resistance mechanism discordances observed, 22 were resistance detection failures and 24 concerned Pseudomonas aeruginosa. CONCLUSIONS: Compared to conventional microbiological cultures, the Unyvero pneumonia cartridge had poor diagnostic performance: it correctly identified pathogens and their resistance mechanisms in 73% and 67% of VAP cases, respectively. The lack of performance on the resistance mechanism was more pronounced when the pathogen detected was a Pseudomonas aeruginosa.


Asunto(s)
Reacción en Cadena de la Polimerasa Multiplex/métodos , Neumonía Asociada al Ventilador/diagnóstico , Adulto , Antibacterianos/uso terapéutico , Lavado Broncoalveolar/métodos , Líquido del Lavado Bronquioalveolar/microbiología , Farmacorresistencia Microbiana/efectos de los fármacos , Farmacorresistencia Microbiana/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa Multiplex/normas , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Neumonía Asociada al Ventilador/diagnóstico por imagen , Sistemas de Atención de Punto/normas , Sistemas de Atención de Punto/estadística & datos numéricos , Puntuación Fisiológica Simplificada Aguda
4.
J Infect Chemother ; 26(1): 82-85, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31383498

RESUMEN

BACKGROUND: Rapid molecular diagnosis of infections has contributed to timely treatments and antimicrobial stewardship. However, the benefit and cost-effectiveness vary in each country or community because they have different standard practices and health care systems. In Japan, rapid antigen tests (RATs) have been frequently used for pediatric respiratory infections. We investigated the impact and cost-effectiveness of a multiplex PCR (mPCR) respiratory panel for pediatric respiratory infections in a Japanese community hospital. METHODS: We replaced RATs with an mPCR respiratory panel (FilmArray®) for admitted pediatric respiratory infections on March 26, 2018. We compared the days of antimicrobial therapy (DOT) and length of stay (LOS) during the mPCR period (March 2018 to April 2019) with those of the RAT period (March 2012 to March 2018). RESULTS: During the RAT and mPCR periods, 1132 and 149 patients were analyzed. The DOT/case was 12.82 vs 8.56 (p < 0.001), and the LOS was 8.18 vs 6.83 days (p = 0.032) in the RAT and mPCR groups, respectively. The total costs during admissions were ∖258,824 ($2331.7) and ∖243,841 ($2196.8)/case, respectively. Pathogen detection rates were 30.2% vs 87.2% (p < 0.001). CONCLUSION: Compared to conventional RATs, the mPCR test contributed to a reduction in the DOT and LOS in a Japanese community hospital for admission-requiring pediatric respiratory infections. However, a proper stewardship program is essential to further reduce the unnecessary usage of antimicrobials.


Asunto(s)
Programas de Optimización del Uso de los Antimicrobianos , Infecciones Bacterianas , Tipificación Molecular , Reacción en Cadena de la Polimerasa Multiplex , Infecciones del Sistema Respiratorio , Antibacterianos/administración & dosificación , Antibacterianos/uso terapéutico , Infecciones Bacterianas/diagnóstico , Infecciones Bacterianas/tratamiento farmacológico , Infecciones Bacterianas/microbiología , Niño , Preescolar , Femenino , Hospitalización , Humanos , Lactante , Japón , Masculino , Tipificación Molecular/economía , Tipificación Molecular/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/economía , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Infecciones del Sistema Respiratorio/diagnóstico , Infecciones del Sistema Respiratorio/tratamiento farmacológico , Infecciones del Sistema Respiratorio/microbiología , Estudios Retrospectivos , Tiempo de Tratamiento
5.
BMC Pediatr ; 19(1): 345, 2019 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-31601181

RESUMEN

BACKGROUND: Acute respiratory infections (ARIs) are one of the main causes of morbidity and mortality in children. Viruses are the main etiological agents, and their behavior tends to be seasonal and vary by geographical location. Human metapneumovirus (HMPV) has recently been described as a cause of severe acute respiratory infection and its prevalence and clinical behavior in children at moderate altitudes is unknown. METHODS: A cross-sectional study was carried out on patients seen at a university hospital in Bogotá, Colombia between October 2015 and December 2017 in a city at a moderate altitude above sea level. Children with acute respiratory infections who had had a multiplex RT-PCR assay were selected. The prevalence of HMPV infection, its clinical outcomes and its relationship to rainfall were evaluated. RESULTS: Out of a total of 14,760 discharged patients, multiplex RT-PCR was performed on 502 and a virus was detected in 420 children with acute respiratory infection (ARI). The study group had a median age of 21 months (IQR 7-60), with similar proportion of males and females (56.4 and 43.6% respectively) and 5.2% (CI 95 3.3-7.8%) prevalence of HMPV infection. The group with HMPV infection showed a greater frequency of viral coinfection (22.7% vs 14% P = 0.03) compared with ARI caused by other viruses. The rate of bacterial coinfection (P = 0.31), presence of comorbidities (p = 0.75), length of hospital stay (P = 0.42), need for mechanical ventilation (P = 0.75) and mortality (P = 0.22) were similar for HMPV and other viral infections. A moderate correlation was established between HMPV infection and rainfall peaks (Spearman's Rho 0.44 p = 0.02). CONCLUSIONS: Human metapneumovirus was the fifth most frequently isolated virus in children with ARI, had similar clinical behavior and severity to other viruses but a higher rate of viral coinfection. Its peaks seem to correlate to rainy seasons.


Asunto(s)
Altitud , Colombia , Metapneumovirus/aislamiento & purificación , Infecciones por Paramyxoviridae/epidemiología , Lluvia , Infecciones del Sistema Respiratorio/epidemiología , Enfermedad Aguda , Niño , Preescolar , Coinfección/microbiología , Coinfección/virología , Colombia/epidemiología , Infecciones Comunitarias Adquiridas/epidemiología , Infecciones Comunitarias Adquiridas/virología , Comorbilidad , Estudios Transversales , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Lactante , Masculino , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Infecciones por Paramyxoviridae/terapia , Prevalencia , Respiración Artificial/estadística & datos numéricos , Infecciones del Sistema Respiratorio/terapia , Infecciones del Sistema Respiratorio/virología , Distribución por Sexo , Resultado del Tratamiento
6.
Medicina (Kaunas) ; 55(8)2019 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-31366156

RESUMEN

BACKGROUND AND OBJECTIVES: Human papillomavirus (HPV) is the most prevalent etiological agent of viral sexually-transmitted infection. This study retrospectively evaluated the impact of a switch to a real-time PCR assay in the HPV prevalence and genotypes distribution by a quasi-experimental before-and-after approach. MATERIALS AND METHODS: In total, 1742 samples collected from 1433 patients were analyzed at the UOC Microbiology and Virology of Policlinico of Bari, Italy. HPV DNA detection was performed using initially nested PCR and subsequently multiplex real-time PCR assay. RESULTS: Statistically significant difference in HPV overall prevalence after the introduction of the real-time assay was not detected (48.97% vs. 50.62%). According to different extraction-DNA amplification methods, differences were observed in the prevalence rates of HPV-45, 68, 40, 42, and 43. The lowest prevalence for HPV-45 was observed in the Magna Pure-Real Time PCR group, while HPV-68, 40, 42, and 43 were less observed in the Qiagen-Real Time PCR group. After, a multivariate logistic regression, an increase in the prevalence of HPV-42 (aOR: 4.08, 95% CI: 1.71-9.73) was associated with the multiplex real-time PCR assay. CONCLUSIONS: Although this study is a not a direct comparison between two diagnostic methods because it has a sequential structure, it serves to verify the impact of a new molecular assay on HPV distribution. Moreover, the stability of HPV prevalence over time suggests that the population composition and the behavioral variables did not likely change during the observation period. Our study proposes that the introduction of a molecular test for HPV detection may be related to changes of HPV genotypes distribution.


Asunto(s)
Reacción en Cadena de la Polimerasa Multiplex/normas , Infecciones por Papillomavirus/virología , Reacción en Cadena de la Polimerasa/normas , Humanos , Italia , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Papillomaviridae/genética , Reacción en Cadena de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa/estadística & datos numéricos , Prevalencia , Estudios Retrospectivos
7.
J Clin Microbiol ; 56(6)2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29643194

RESUMEN

Clostridium difficile colonizes the gastrointestinal (GI) tract, resulting in either asymptomatic carriage or a spectrum of diarrheal illness. If clinical suspicion for C. difficile is low, stool samples are often submitted for analysis by multiplex molecular assays capable of detecting multiple GI pathogens, and some institutions do not report this organism due to concerns for high false-positive rates. Since clinical disease correlates with organism burden and molecular assays yield quantitative data, we hypothesized that numerical cutoffs could be utilized to improve the specificity of the Luminex xTAG GI pathogen panel (GPP) for C. difficile infection. Analysis of cotested liquid stool samples (n = 1,105) identified a GPP median fluorescence intensity (MFI) value cutoff of ≥1,200 to be predictive of two-step algorithm (2-SA; 96.4% concordance) and toxin enzyme immunoassay (EIA) positivity. Application of this cutoff to a second cotested data set (n = 1,428) yielded 96.5% concordance. To determine test performance characteristics, concordant results were deemed positive or negative, and discordant results were adjudicated via chart review. Test performance characteristics for the MFI cutoff of ≥150 (standard), MFI cutoff of ≥1,200, and 2-SA were as follows (respectively): concordance, 95, 96, and 97%; sensitivity, 93, 78, and 90%; specificity, 95, 98, and 98%; positive predictive value, 67, 82, and 81%;, and negative predictive value, 99, 98, and 99%. To capture the high sensitivity for organism detection (MFI of ≥150) and high specificity for active infection (MFI of ≥1,200), we developed and applied a reporting algorithm to interpret GPP data from patients (n = 563) with clinician orders only for syndromic panel testing, thus enabling accurate reporting of C. difficile for 95% of samples (514 negative and 5 true positives) irrespective of initial clinical suspicion and without the need for additional testing.


Asunto(s)
Algoritmos , Clostridioides difficile/aislamiento & purificación , Infecciones por Clostridium/diagnóstico , Técnicas de Diagnóstico Molecular/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Adolescente , Adulto , Anciano , Toxinas Bacterianas/análisis , Niño , Enterotoxinas/análisis , Heces/microbiología , Femenino , Fluorescencia , Humanos , Técnicas para Inmunoenzimas , Masculino , Persona de Mediana Edad , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Adulto Joven
8.
J Clin Microbiol ; 56(4)2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29343540

RESUMEN

INTRODUCTIONSyndromic panels were first FDA cleared for detection of respiratory pathogens in 2008. Since then, other panels have been approved by the FDA, and most recently, the FilmArray meningitis/encephalitis panel (BioFire, Salt Lake City, UT) has become available. This assay detects 14 targets within 1 h and includes pathogens that typically cause different manifestations of infection, although they infect the same organ system. Several studies have reported both false-positive and false-negative results with this test, and all agree that the cost is significant. As with other panels, health care systems have adopted different strategies for offering this assay. Some have implemented strategies to limit the use of the test to certain patient populations, others have elected not to offer the test, and others have elected not to offer the test and instead request that providers order specific PCRs for the pathogens that best fit the patient's symptoms. In this Point-Counterpoint, Jennifer Dien Bard of the Department of Pathology and Laboratory Medicine, Children's Hospital Los Angeles, and of the Keck School of Medicine at the University of Southern California explains why laboratories should offer these assays without restriction. Kevin Alby of the University of Pennsylvania explains the concerns about the use of these assays as first-line tests and why some limitations on their use might be appropriate.


Asunto(s)
Encefalitis/diagnóstico , Meningitis/diagnóstico , Técnicas de Diagnóstico Molecular/estadística & datos numéricos , Niño , Preescolar , Equipo para Diagnóstico/economía , Equipo para Diagnóstico/estadística & datos numéricos , Encefalitis/virología , Humanos , Meningitis/microbiología , Técnicas de Diagnóstico Molecular/economía , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Neisseria meningitidis/genética , Neisseria meningitidis/aislamiento & purificación , Simplexvirus/genética , Simplexvirus/aislamiento & purificación , Streptococcus pneumoniae/aislamiento & purificación , Síndrome , Estados Unidos , United States Food and Drug Administration
9.
J Clin Microbiol ; 55(4): 1154-1161, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28122874

RESUMEN

The FilmArray gastrointestinal (GI) panel (BioFire Diagnostics, Salt Lake City, UT) is a simple, sample-to-answer, on-demand, multiplex, nucleic acid amplification test for syndromic diagnosis of infectious gastroenteritis. The aim of this study was to measure the yield of follow-up testing with FilmArray GI panel within 4 weeks of an initial test. Consecutive adult and pediatric patients tested at an academic institution between August 2015 and June 2016 were included in this study. Of 145 follow-up tests in 106 unique patients with an initial negative result, 134 (92.4%) tests and 98 (92.5%) patients remained negative upon follow-up testing. Excluding targets that are not reported at this institution (Clostridium difficile, enteroaggregative Escherichia coli, enteropathogenic E. coli, and enterotoxigenic E. coli), 137 (94.5%) follow-up tests and 101 (95.3%) patients remained negative. Weekly conversion rates were not significantly different across the 4-week follow-up interval. No epidemiological or clinical factors were significantly associated with a negative to positive conversion. Of 80 follow-up tests in patients with an initial positive result, 43 (53.8%) remained positive for the same target, 34 (42.5%) were negative, and 3 were positive for a different target (3.8%). Follow-up testing with FilmArray GI panel within 4 weeks of a negative result rarely changed the initial result, and the follow-up test reverted to negative less than half the time after an initial positive result. In the absence of clinical or epidemiological evidence for a new infection, follow-up testing should be limited and FilmArray GI panel should not be used as a test of cure.


Asunto(s)
Gastroenteritis/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
10.
Jpn J Antibiot ; 67(5): 285-92, 2014 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-25566591

RESUMEN

We developed and evaluated of multiplex real-time PCR assay for detection of vancomycin-resistant genes (vanA, vanB, vanC1 and vanC2/C3) using the new, fully automated BD MAX platform. Ct value analyses of real-time PCR simultaneous repeatability test have showed the usefulness; coefficient of variation: CV (%) were determined 2.09%, 1.72%, 1.41% and 1.52% with vanA, vanB, vanC1 and vanC2/C3, respectively. We also evaluated with 43 strains of enterococci were characterized by conventional PCR method; 4/4 for vanA-positive, 14/14 for vanB-positive, 1/1 for vanB plus vanC1-positive, 6/6 for vanC1-positive, 4/4 for vanC2/C3- positive and 14/14 for all-van gene-negative strains were identified correctly. This assay was automatically performing before and after PCR operations previously done manually by operator, such as DNA extraction, sample dispensing and gel electrophoresis or the ethidium bromide dyeing. As a result, work burden and the risk of the contamination were largely reduced and were shortened to about half for measurement time. We conclude that this assay could greatly contribute to efficient and rapid detection of vancomycin-resistant genes.


Asunto(s)
Enterococcus/genética , Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , Resistencia a la Vancomicina/genética , Enterococcus/efectos de los fármacos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos
12.
East Mediterr Health J ; 19(3): 255-62, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23879077

RESUMEN

Approximately 5%-10% of all breast cancers are inherited as the result of germline mutations in the BRCAl gene. Large genomic rearrangements (LGRs) in BRCA1 have not been well-researched in the Egyptian population. Using multiplex ligation-dependent probe amplification, we showed BRCA1 rearrangements in 4/22 cases (18.2%) of familial breast cancer. No influence of having multiple breast cancer cases within the family was observed in patients diagnosed at or=45 years and having BRCAl-positive LGRs. However, focusing on cases with first- and second-degree relatives affected, we observed a significant difference between the percentage of patients with BRCA1-positive versus BRCAl-negative LGRs. Our results provide the first evidence that LGRs in BRCA1 exist in the Egyptian population. Screening for these alterations may be desirable when breast cancer patients are diagnosed at an early age, especially if these cases have first- and second-degree of relatives with breast cancer.


Asunto(s)
Neoplasias de la Mama/genética , Salud de la Familia/estadística & datos numéricos , Genes BRCA1 , Pruebas Genéticas/métodos , Adulto , Edad de Inicio , Anciano , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/epidemiología , Egipto/epidemiología , Femenino , Pruebas Genéticas/estadística & datos numéricos , Humanos , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos
13.
Int J Legal Med ; 125(5): 685-94, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21258942

RESUMEN

This paper presents a system for the multiplex amplification of 15 loci, known as I-DNA1, which combines mini and midiSTR technology, with amplicon sizes ranging from 49 to 297 bp. I-DNA1 analyses all the STR loci included in the CODIS and the Interpol Standard Set of loci, nine of the ten European core loci and seven of the eight German core loci, making it suitable for use in identifying humans. Moreover, its high sensitivity and the small size of its amplicons mean that I-DNA1 is potentially highly useful for analysing highly degraded and/or very small DNA samples.


Asunto(s)
Dermatoglifia del ADN/legislación & jurisprudencia , Dermatoglifia del ADN/métodos , Antropología Forense/legislación & jurisprudencia , Antropología Forense/métodos , Sitios Genéticos/genética , Repeticiones de Microsatélite/genética , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Juego de Reactivos para Diagnóstico/estadística & datos numéricos , Dermatoglifia del ADN/estadística & datos numéricos , Femenino , Frecuencia de los Genes/genética , Humanos , Hígado/patología , Masculino , Miocardio/patología , Cambios Post Mortem , Reproducibilidad de los Resultados , España
14.
Medicine (Baltimore) ; 100(18): e25768, 2021 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-33950965

RESUMEN

ABSTRACT: This study aimed to compare interphase fluorescence in situ hybridization (iFISH) and multiplex ligation dependent probe amplification (MLPA) for identifying genetic changes in myelodysplastic syndromes (MDS).The frequencies of cytogenetic changes in MDS patients treated at the Institute of Hematology and Blood Disease Hospital (China) in 2009 to 2018 were assessed by iFISH based on bone marrow samples. Then, the effectiveness of MLPA in detecting these anomalies was evaluated.Specimens from 287 MDS patients were assessed. A total of 36.9% (103/279) of MDS cases had chromosomal abnormalities detected by iFISH; meanwhile, 44.1% (123/279) harbored ≥1 copy-number variation (CNV) based on MLPA: +8 (n=46), -5 (n = 39), -7 (n = 27), del 20 (n = 32) and del 17 (n = 17). Overall, 0 to 4 aberrations/case were detected by MLPA, suggesting the heterogeneous and complex nature of MDS cytogenetics. There were 29 cases detected by MLPA, which were undetected by FISH or showed low signals. Sixteen of these cases had their risk classification changed due to MLPA detection, including 9 reassigned to the high-risk IPSS-R group. These findings demonstrated that MLPA is highly efficient in assessing cytogenetic anomalies, with data remarkably corroborating FISH findings (overall consistency of 97.1%). The sensitivities of MLPA in detecting +8, -5, -7, del 20 and del 17 were 92.3%, 97.1%, 100%, 100%, and 90%, respectively, with specificities of 95.8%, 97.6%, 97.7%, 97.6%, and 97%, respectively.MLPA represents a reliable approach, with greater efficiency, accuracy, and speed than iFISH in identifying cytogenetic aberrations in MDS.


Asunto(s)
Aberraciones Cromosómicas , Análisis Citogenético/métodos , Hibridación Fluorescente in Situ/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Síndromes Mielodisplásicos/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Síndromes Mielodisplásicos/epidemiología , Síndromes Mielodisplásicos/genética , Síndromes Mielodisplásicos/terapia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo/métodos , Medición de Riesgo/estadística & datos numéricos , Factores de Tiempo
15.
Biosens Bioelectron ; 178: 113041, 2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33545551

RESUMEN

The outbreak of COVID-19 caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been challenging human health worldwide. Loop-mediated isothermal amplification (LAMP) has been promptly applied to the detection of SARS-CoV-2 owing to its high amplification efficacy and less requirement of the thermal cycler. However, the vast majority of these LAMP-based assays depend on the non-specific detection of LAMP products, which can not discern the undesirable amplificons, likely to yield unreliable results. Herein, a sequence-specific LAMP assay was reported to detect SARS-CoV-2 using proofreading enzyme-mediated probe cleavage (named Proofman), which could realize real-time and visual detection without uncapping. This assay, introducing a proofreading enzyme and the fluorogenic probe to reverse-transcription LAMP (RT-Proofman-LAMP), can specifically detect the SARS-CoV-2 RNA with a detection limit of 100 copies. In addition to the real-time analysis, the assay is capable of endpoint visualization under a transilluminator within 50 min, providing a convenient reporting manner under the setting of point-of-care testing (POCT). In combination with different fluorophores, the one-pot multiplex assay was successfully achieved to detect multiple targets of SARS-CoV-2 and inner control simultaneously. In summary, the development of RT-Proofman-LAMP offers a versatile and highly-specific method for fast field screening and laboratory testing of SARS-CoV-2, making it a promising platform in COVID-19 diagnosis.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virología , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Técnicas Biosensibles/métodos , Técnicas Biosensibles/estadística & datos numéricos , Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , Humanos , Límite de Detección , Técnicas de Diagnóstico Molecular/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Técnicas de Amplificación de Ácido Nucleico/estadística & datos numéricos , Pandemias , Sistemas de Atención de Punto/estadística & datos numéricos , ARN Viral/análisis , ARN Viral/genética , Sensibilidad y Especificidad
16.
Ann Agric Environ Med ; 27(4): 713-716, 2020 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-33356083

RESUMEN

B-cell precursor acute lymphoblastic leukemia (BCP-ALL) is the most common childhood cancer. A special subtype of high risk BCP-ALL is Philadelphia-like ALL (Ph-like ALL), in which the gene expression profile is similar to BCR-ABL1-positive leukemia; however, fusion of the mentioned genes does not occur. The unfavourable clinical course and incidence of 15% of cases means that the diagnosis and therapeutic strategy of Ph-like ALL must be carefully developed and implemented into clinical practice. The study presents the case of a patient with diagnosed Ph-like ALL. The use of molecular analytical techniques has made it possible to identify a patient who is likely to relapse and who may benefit from personalized therapy This study shows the advantages of using genomic analyses to identify therapeutic targets, which is especially important for patients with high-risk disease. This model of management could be extended to other cancer subtypes, allowing for tailored diagnosis.


Asunto(s)
Análisis por Micromatrices/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Leucemia-Linfoma Linfoblástico de Células Precursoras B/terapia , Enfermedad Aguda/terapia , Niño , Humanos , Masculino , Polonia , Resultado del Tratamiento
17.
PLoS One ; 15(12): e0243261, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33270790

RESUMEN

BACKGROUND: Rapid identification of patients with high suspicion of COVID-19 will become a challenge with the co-circulation of multiple respiratory viruses (RVs). We have identified clinical or biological characteristics to help distinguish SARS-CoV-2 from other RVs. METHODS: We used a prospective cohort including all consecutive patients admitted through the emergency department's (ED) and presenting respiratory symptoms from November 2019 to April 2020. Patients were tested for RV using multiplex polymerase chain reaction (mPCR) and SARS-CoV-2 RT-PCR. RESULTS: 203/508 patients were positive for an RV during the non-SARS-CoV-2 epidemic period (November to February), and 268/596 patients were SARS-CoV-2 positive during the SARS-CoV-2 epidemic (March to April). Younger age, male gender, fever, absence of expectoration and absence of chronic lung disease were statistically associated with SARS-CoV-2 detection. Combining these variables allowed for the distinguishing of SARS-CoV-2 infections with 83, 65, 75 and 76% sensitivity, specificity, PPV and NPV, respectively. CONCLUSION: Patients' characteristics associated with a positive PCR are common between SARS-CoV-2 and other RVs, but a simple discrimination of strong SARS-CoV-2 suspicion with a limited set of clinical features seems possible. Such scoring could be useful but has to be prospectively evaluated and will not eliminate the need for rapid PCR assays.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , COVID-19/epidemiología , Servicio de Urgencia en Hospital/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Pruebas en el Punto de Atención/estadística & datos numéricos
18.
Biomed Res Int ; 2020: 7610678, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33029522

RESUMEN

BACKGROUND: There is a shortage of chemical reagents for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis and a surge of SARS-CoV-2 cases, especially in limited-resource settings. Therefore, the combination of an optimal assay kit is necessary. METHODS: We compared the ability to screen SARS-CoV-2 among three primer-probe sets in two different master mixes, Invitrogen™ SuperScript™ III One-Step RT-PCR and LightCycler Multiplex RNA Virus Master. RESULTS: The assay with TIB-Molbiol, IDT, and Phu Sa sets for LightCycler Multiplex RNA Virus Master or Invitrogen™ SuperScript™ III One-Step RT-PCR showed positive results from a single reaction of triplicate in the three days of 4.8 copies per reaction. R squared and amplification efficiency were 0.97 and ranged from 107 to 108%, respectively. CONCLUSIONS: Our findings indicated that TIB-Molbiol, IDT, and Phu Sa primer-probe sets could be beneficial for the laboratory screening of SARS-CoV-2 by RT-qPCR assay of E gene. There is a need to consider the combination of these reagent sets as a new strategy to increase the testing capacity of screening programs for COVID-19.


Asunto(s)
Betacoronavirus/genética , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Cartilla de ADN/genética , Neumonía Viral/diagnóstico , Sondas ARN/genética , Betacoronavirus/aislamiento & purificación , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/virología , Humanos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Pandemias , Neumonía Viral/epidemiología , Neumonía Viral/virología , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/estadística & datos numéricos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/estadística & datos numéricos , SARS-CoV-2 , Sensibilidad y Especificidad
19.
Nat Commun ; 11(1): 2607, 2020 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-32451375

RESUMEN

Quantification of pathogen and host biomarkers is essential for the diagnosis, monitoring, and treatment of infectious diseases. Here, we demonstrate sensitive and rapid quantification of bacterial load and cytokines from human biological samples to generate actionable hypotheses. Our digital assay measures IL-6 and TNF-α proteins, gram-negative (GN) and gram-positive (GP) bacterial DNA, and the antibiotic-resistance gene blaTEM with femtomolar sensitivity. We use our method to characterize bronchoalveolar lavage fluid from patients with asthma, and find elevated GN bacteria and IL-6 levels compared to healthy subjects. We then analyze plasma from patients with septic shock and find that increasing levels of IL-6 and blaTEM are associated with mortality, while decreasing IL-6 levels are associated with recovery. Surprisingly, lower GN bacteria levels are associated with higher probability of death. Applying decision-tree analysis to our measurements, we are able to predict mortality and rate of recovery from septic shock with over 90% accuracy.


Asunto(s)
Citocinas/sangre , ADN Bacteriano/sangre , Choque Séptico/inmunología , Choque Séptico/microbiología , Asma/inmunología , Asma/microbiología , Carga Bacteriana , Biomarcadores/análisis , Biomarcadores/sangre , Líquido del Lavado Bronquioalveolar/química , Líquido del Lavado Bronquioalveolar/inmunología , Líquido del Lavado Bronquioalveolar/microbiología , Estudios de Casos y Controles , Citocinas/análisis , ADN Bacteriano/genética , Árboles de Decisión , Genes Bacterianos , Bacterias Gramnegativas/genética , Bacterias Gramnegativas/aislamiento & purificación , Bacterias Grampositivas/genética , Bacterias Grampositivas/aislamiento & purificación , Interacciones Microbiota-Huesped/inmunología , Humanos , Interleucina-6/análisis , Interleucina-6/sangre , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Pronóstico , Sensibilidad y Especificidad , Choque Séptico/mortalidad , Factor de Necrosis Tumoral alfa/análisis , Factor de Necrosis Tumoral alfa/sangre , Resistencia betalactámica/genética
20.
Biosens Bioelectron ; 166: 112437, 2020 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-32692666

RESUMEN

The ongoing global pandemic (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has become a huge public health issue. Hence, we devised a multiplex reverse transcription loop-mediated isothermal amplification (mRT-LAMP) coupled with a nanoparticle-based lateral flow biosensor (LFB) assay (mRT-LAMP-LFB) for diagnosing COVID-19. Using two LAMP primer sets, the ORF1ab (opening reading frame 1a/b) and N (nucleoprotein) genes of SARS-CoV-2 were simultaneously amplified in a single-tube reaction, and detected with the diagnosis results easily interpreted by LFB. In presence of FITC (fluorescein)-/digoxin- and biotin-labeled primers, mRT-LAMP produced numerous FITC-/digoxin- and biotin-attached duplex amplicons, which were determined by LFB through immunoreactions (FITC/digoxin on the duplex and anti-FITC/digoxin on the test line of LFB) and biotin/treptavidin interaction (biotin on the duplex and strptavidin on the polymerase nanoparticle). The accumulation of nanoparticles leaded a characteristic crimson band, enabling multiplex analysis of ORF1ab and N gene without instrumentation. The limit of detection (LoD) of COVID-19 mRT-LAMP-LFB was 12 copies (for each detection target) per reaction, and no cross-reactivity was generated from non-SARS-CoV-2 templates. The analytical sensitivity of SARS-CoV-2 was 100% (33/33 oropharynx swab samples collected from COVID-19 patients), and the assay's specificity was also 100% (96/96 oropharynx swab samples collected from non-COVID-19 patients). The total diagnostic test can be completed within 1 h from sample collection to result interpretation. In sum, the COVID-19 mRT-LAMP-LFB assay is a promising tool for diagnosing SARS-CoV-2 infections in frontline public health field and clinical laboratories, especially from resource-poor regions.


Asunto(s)
Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , Técnicas Biosensibles , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/virología , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/virología , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Técnicas Biosensibles/estadística & datos numéricos , COVID-19 , Prueba de COVID-19 , China/epidemiología , Técnicas de Laboratorio Clínico/instrumentación , Técnicas de Laboratorio Clínico/métodos , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Infecciones por Coronavirus/epidemiología , Diseño de Equipo , Estudios de Factibilidad , Humanos , Límite de Detección , Técnicas de Diagnóstico Molecular , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Nanopartículas , Nanotecnología , Técnicas de Amplificación de Ácido Nucleico , Neumonía Viral/epidemiología , ARN Viral/análisis , ARN Viral/genética , SARS-CoV-2 , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA