Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Comput Assist Tomogr ; 44(5): 784-789, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32558773

RESUMEN

OBJECTIVE: The objective of this study was to examine whether left atrial (LA) volumes and function were associated with atrial high-rate episodes (AHREs) in patients with cardiac resynchronization therapy (CRT). METHODS: Ninety-two consecutive patients without prior atrial fibrillation underwent clinical evaluation, echocardiograms, and cardiac computed tomography (CT) before CRT implantation and after 6 months. Left atrial volumes and LA emptying fraction (LAEF) were derived by CT images reconstructed at 5% phase increments of the cardiac cycle. Cox regression was used to assess associations between AHRE and LA anatomical and functional variables. RESULTS: Twenty-two patients (24%) developed AHRE during 1.9 years (SD, 1 year) At baseline, higher LAEF was associated with a lower risk of AHRE (hazard ratio [HR], 0.94; 95% confidence interval [CI], 0.91-0.98; P = 0.003), and large LA minimal (LAmin) volume was related to higher risk of AHRE (HR, 1.03; 95% CI, 1.00-1.06; P = 0.04). When combining LAEF and LAmin volume, only LAEF remained associated with occurrence of AHRE. Higher passive LAEF was associated with lower risk of AHRE (HR, 0.95; 95% CI, 0.91-0.98; P = 0.003). CONCLUSIONS: In patients with CRT, low preimplant LAEF measured by cardiac CT was independently associated with device-detected AHRE.


Asunto(s)
Fibrilación Atrial , Función del Atrio Izquierdo/fisiología , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Atrios Cardíacos/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo
2.
J Card Fail ; 25(10): 812-818, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31479745

RESUMEN

BACKGROUND: The beneficial effects of a cardiac resynchronization defibrillator (CRT-D) in patients with heart failure, low left ventricular ejection fraction (LVEF), and wide QRS have clearly been established. Nevertheless, mortality remains high in some patients. The aim of this study was to develop and validate a risk score to identify patients at high risk for early mortality who are implanted with a CRT-D. METHODS AND RESULTS: For predictive modelling, 1282 consecutive patients from 5 centers (74% male; median age 66 years; median LVEF 25%; New York Heart Association class III-IV 60%; median QRS-width 160 ms) were randomly divided into a derivation and validation cohort. The primary endpoint is mortality at 3 years. Model development was performed using multivariate logistic regression by checking log likelihood, Akaike information criterion, and Bayesian information criterion. Model performance was validated using C statistics and calibration plots. The risk score included 7 independent mortality predictors, including myocardial infarction, LVEF, QRS duration, chronic obstructive pulmonary disease, chronic kidney disease, hyponatremia, and anemia. Calibration-in-the-large was suboptimal, reflected by a lower observed mortality (44%) than predicted (50%). The validated C statistic was 0.71 indicating modest performance. CONCLUSION: A risk score based on routine, readily available clinical variables can assist in identifying patients at high risk for early mortality within 3 years after CRT-D implantation.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Medición de Riesgo/métodos , Anciano , Bélgica/epidemiología , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Desfibriladores Implantables/estadística & datos numéricos , Cardioversión Eléctrica/estadística & datos numéricos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Estimación de Kaplan-Meier , Masculino , Mortalidad , Países Bajos/epidemiología , Pronóstico , Sistema de Registros/estadística & datos numéricos , Factores de Riesgo , Volumen Sistólico , Suiza/epidemiología , Función Ventricular Izquierda
4.
Europace ; 20(9): 1513-1526, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29309556

RESUMEN

Aims: To provide comprehensive information on the access and use of cardiac implantable electronic devices (CIED) and catheter ablation procedures in Africa. Methods and results: The Pan-African Society of Cardiology (PASCAR) collected data on invasive management of cardiac arrhythmias from 2011 to 2016 from 31 African countries. A specific template was completed by physicians, and additional information obtained from industry. Information on health care systems, demographics, economics, procedure rates, and specific training programs was collected. Considerable heterogeneity in the access to arrhythmia care was observed across Africa. Eight of the 31 countries surveyed (26%) did not perform pacemaker implantations. The median pacemaker implantation rate was 2.66 per million population per country (range: 0.14-233 per million population). Implantable cardioverter-defibrillator and cardiac resynchronization therapy were performed in 12/31 (39%) and 15/31 (48%) countries respectively, mostly by visiting teams. Electrophysiological studies, including complex catheter ablations were performed in all countries from Maghreb, but only one sub-Saharan African country (South Africa). Marked variation in cost (up to 1000-fold) was observed across countries with an inverse correlation between implant rates and the procedure fees standardized to the gross domestic product per capita. Lack of economic resources and facilities, high cost of procedures, deficiency of trained physicians, and non-existent fellowship programs were the main drivers of under-utilization of interventional cardiac arrhythmia care. Conclusion: There is limited access to CIED and ablation procedures in Africa. A quarter of countries did not have pacemaker implantation services, and catheter ablations were only available in one country in sub-Saharan Africa.


Asunto(s)
Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Cardiología/estadística & datos numéricos , Ablación por Catéter/estadística & datos numéricos , Implantación de Prótesis/estadística & datos numéricos , Comités Consultivos , África , Terapia de Resincronización Cardíaca/economía , Cardiología/educación , Ablación por Catéter/economía , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Costos de la Atención en Salud , Gastos en Salud , Fuerza Laboral en Salud , Humanos , Marcapaso Artificial , Implantación de Prótesis/economía , Sociedades Médicas
5.
Europace ; 20(11): e171-e178, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29294014

RESUMEN

Aims: Right bundle branch block (RBBB) typically presents with only delayed right ventricular activation. However, some patients with RBBB develop concomitant delayed left ventricular (LV) activation. Such patients may show a specific electrocardiographic (ECG) pattern resembling RBBB in the precordial leads in association with an insignificant S-wave in lateral limb leads (atypical RBBB). We therefore postulated that the ECG pattern of atypical RBBB might be able to identify a subgroup of patients likely to respond to cardiac resynchronization therapy (CRT). The purpose of this study was to assess the impact of RBBB ECG morphology on CRT response in patients with heart failure (HF). Methods and results: We evaluated the echocardiographic clinical response of 66 patients with RBBB treated with CRT and followed up for almost 2 years. The patients were divided electrocardiographically into 2 groups: 31 with typical RBBB and 35 with atypical RBBB. Responders were classified in terms of reduction in LV end-systolic volume index (ESVi) ≥ 15% or reduction in the New York Heart Association (NYHA) Class ≥ 1 or Packer score variation (NYHA response with no HF-related hospitalization events or death). The atypical RBBB group presented a longer LV activation time compared with the typical RBBB group (111.9 ± 17.6 vs. 73.2 ± 15.4 ms; P < 0.001). In the atypical and typical RBBB groups, respectively, 71.4% and 19.4% of patients were ESVi responders (P = 0.001) 74.3% and 32.3% were NYHA responders (P = 0.002); similarly, 71.4% and 29.0% of patients exhibited a 2-year Packer score of 0 (P = 0.002). Conclusion: Patients with atypical RBBB, which is a pattern highly suggestive of concomitant delayed LV conduction, may show a satisfactory response to CRT.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Ecocardiografía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Anciano , Bloqueo de Rama/complicaciones , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud
6.
Europace ; 20(5): e69-e77, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28679168

RESUMEN

Aims: Cardiac resynchronization therapy defibrillators (CRT-D) are able to monitor various parameters that may be combined by an automatic algorithm to provide a heart failure risk status (HFRS). We sought to validate the HFRS for stratifying patient risk, evaluate its association with heart failure (HF) symptoms, and investigate its utility for triage of automatic alerts. Methods and results: Data from 722 patients included in the MORE-CARE trial were analysed in a post hoc analysis. A high HFRS was associated with a significantly increased risk of admission over the next 30 days with a relative risk for cardiovascular hospitalization (CVH) of 4.5 (95% CI: 3.1-6.6, P < 0.001), of HF hospitalization of 6.3 (95% CI: 3.9-10.2, P < 0.001) and of non-HF related CVH of 3.5 (95% CI: 2.0-6.9, P < 0.001). The negative predictive value of low or medium HFRS for these admissions was ≥98%. A high HFRS was associated with an increased risk of HF symptoms. Of all the automatic remote monitoring alerts generated during the study, only 10% had a high HFRS. Conclusion: The HFRS is able to risk-stratify CRT-D patients, which is potentially useful for managing automatic remote monitoring alerts, by focusing attention on the minority of high-risk patients. Clinical Trial Registration: The trial was registered at www.clinicaltrials.gov under number NCT00885677.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables/estadística & datos numéricos , Insuficiencia Cardíaca , Hospitalización/estadística & datos numéricos , Monitoreo Fisiológico/métodos , Tecnología de Sensores Remotos , Anciano , Algoritmos , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Dispositivos de Terapia de Resincronización Cardíaca , Europa (Continente) , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Tecnología de Sensores Remotos/instrumentación , Tecnología de Sensores Remotos/métodos , Tecnología de Sensores Remotos/estadística & datos numéricos , Reproducibilidad de los Resultados , Medición de Riesgo/métodos
7.
Europace ; 20(5): 794-800, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28398490

RESUMEN

Aims: Discordant and concordant left bundle branch block (dLBBB/cLBBB) are characterized by negative or positive T waves, respectively, in lateral leads. We assessed if the two morphologies are associated with different clinical status and prognosis in patients with heart failure (HF) and current indication to Cardiac Resynchronization Therapy (CRT)/CRT-Defibrillator (CRT-D). Methods and results: Baseline electrocardiograms of 1270 patients with LBBB in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy cohort were analysed to identify dLBBB and cLBBB. The two groups were compared with respect to baseline clinical characteristics, primary endpoint (HF event or death), and secondary endpoint (ventricular tachycardia, ventricular fibrillation, or death) over a 3.5-year period, and benefit of CRT-D over implantable cardioverter defibrillator (ICD). dLBBB was identified in 909 (72%) patients, and cLBBB in 361 (28%). Patients with dLBBB were older, had more severe symptoms and systolic dysfunction, as well as higher brain natriuretic peptide. CRT-D was superior to ICD in patients with both LBBB morphologies. The occurrence of the primary outcome was significantly more frequent in patients with dLBBB than in those with cLBBB, both in the entire cohort (P = 0.005), and in the CRT-D arm (P = 0.002). There was a trend towards more frequent occurrence of the secondary endpoint in patients with dLBBB than in those with cLBBB, but statistical significance was not reached in the whole population or in the subgroup undergoing CRT-D. Among patients receiving CRT-D, dLBBB was an independent predictor of the primary endpoint. Conclusion: dLBBB morphology is associated with more severe HF clinical status and worse prognosis, even in patients receiving CRT-D, compared with cLBBB morphology.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Desfibriladores Implantables/estadística & datos numéricos , Insuficiencia Cardíaca , Anciano , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Dispositivos de Terapia de Resincronización Cardíaca , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Humanos , Italia , Masculino , Persona de Mediana Edad , Mortalidad , Evaluación de Resultado en la Atención de Salud , Pronóstico , Factores de Riesgo , Índice de Severidad de la Enfermedad
8.
Europace ; 20(6): 979-985, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-28595339

RESUMEN

Aims: Electrical storm (ES) is a condition defined as three or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 h, and usually coexist with advanced heart failure in patients with structural heart disease. The aim of the present study is to test whether cardiac resynchronization therapy (CRT) can be associated with a lower incidence of ES. Methods and results: The OBSERVO-ICD (NCT02735811) is a multicentre, retrospective registry, enrolling all consecutive patients undergoing ICD or CRT-D implantation from 2010 to 2012 in five Italian high-volume arrhythmia centres. Propensity score matching was used to compare two equally sized cohorts of ICD and CRT-D patients with similar characteristics. The primary endpoint was the time free from ES. Secondary endpoints were time free from unclustered VT/VF episodes and time free from ES in CRT-D patients according to clinical or echographic response. CRT-D was associated with a 45% relative risk reduction in ES when compared with ICD (5.6% vs. 12.3%; log rank P = 0.014). CRT-responders presented lower rates of ES when compared with non-responders and negative responders according to both clinical and echographic criteria (log-rank P = 0.017 and 0.023, respectively). No ES was detected in any of the 133 full responders to CRT-D. Clinical and echographic positive responses, but not CRT-implant per se, were associated with lower estimate rates of unclustered VTs/VFs. Conclusion: Patients with CRT had a lower incidence of ES when compared with propensity-matched ICD patients. The long-term benefit of CRT seems to be due to the improved haemodynamics, as CRT-responders performed markedly better over a long-term follow-up.


Asunto(s)
Terapia de Resincronización Cardíaca , Taquicardia Ventricular , Fibrilación Ventricular , Anciano , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hemodinámica , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Sistema de Registros/estadística & datos numéricos , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/fisiopatología
9.
Europace ; 20(11): 1804-1812, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29697764

RESUMEN

Aims: There is a continuing debate as to whether cardiac resynchronization therapy-defibrillation (CRT-D) is superior to CRT-pacing (CRT-P), particularly in patients with non-ischaemic cardiomyopathy (NICM). We sought to quantify the clinical outcomes after primary prevention of CRT-D and CRT-P and identify whether these differed according to the aetiology of cardiomyopathy. Methods and results: Analyses were undertaken in the total study population of patients treated with CRT-D (n = 551) or CRT-P (n = 999) and in propensity-matched samples. Device choice was governed by the clinical guidelines in the United Kingdom. In univariable analyses of the total study population, for a maximum follow-up of 16 years (median 4.7 years, interquartile range 2.4-7.1), CRT-D was associated with a lower total mortality [hazard ratio (HR) 0.72] and the composite endpoints of total mortality or heart failure (HF) hospitalization (HR 0.72) and total mortality or hospitalization for major adverse cardiac events (MACE; HR 0.71) (all P < 0.001). After propensity matching (n = 796), CRT-D was associated with a lower total mortality (HR 0.72) and the composite endpoints (all P < 0.01). When further stratified according to aetiology, CRT-D was associated with a lower total mortality (HR 0.62), total mortality or HF hospitalization (HR 0.63), and total mortality or hospitalization for MACE (HR 0.59) (all P < 0.001) in patients with ischaemic cardiomyopathy (ICM). There were no differences in outcomes between CRT-D and CRT-P in patients with NICM. Conclusion: In this study of real-world clinical practice, CRT-D was superior to CRT-P with respect to total mortality and composite endpoints, independent of known confounders. The benefit of CRT-D was evident in ICM but not in NICM.


Asunto(s)
Estimulación Cardíaca Artificial , Terapia de Resincronización Cardíaca , Cardiomiopatías , Cardioversión Eléctrica , Anciano , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Dispositivos de Terapia de Resincronización Cardíaca , Cardiomiopatías/etiología , Cardiomiopatías/mortalidad , Cardiomiopatías/terapia , Causas de Muerte , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/métodos , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/etiología , Efectos Adversos a Largo Plazo/mortalidad , Masculino , Persona de Mediana Edad , Mortalidad , Prevención Primaria/métodos , Prevención Primaria/estadística & datos numéricos , Resultado del Tratamiento , Reino Unido/epidemiología
10.
Eur Heart J ; 38(30): 2352-2360, 2017 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-28575235

RESUMEN

AIMS: Remote management of heart failure using implantable electronic devices (REM-HF) aimed to assess the clinical and cost-effectiveness of remote monitoring (RM) of heart failure in patients with cardiac implanted electronic devices (CIEDs). METHODS AND RESULTS: Between 29 September 2011 and 31 March 2014, we randomly assigned 1650 patients with heart failure and a CIED to active RM or usual care (UC). The active RM pathway included formalized remote follow-up protocols, and UC was standard practice in nine recruiting centres in England. The primary endpoint in the time to event analysis was the 1st event of death from any cause or unplanned hospitalization for cardiovascular reasons. Secondary endpoints included death from any cause, death from cardiovascular reasons, death from cardiovascular reasons and unplanned cardiovascular hospitalization, unplanned cardiovascular hospitalization, and unplanned hospitalization. REM-HF is registered with ISRCTN (96536028). The mean age of the population was 70 years (range 23-98); 86% were male. Patients were followed for a median of 2.8 years (range 0-4.3 years) completing on 31 January 2016. Patient adherence was high with a drop out of 4.3% over the course of the study. The incidence of the primary endpoint did not differ significantly between active RM and UC groups, which occurred in 42.4 and 40.8% of patients, respectively [hazard ratio 1.01; 95% confidence interval (CI) 0.87-1.18; P = 0.87]. There were no significant differences between the two groups with respect to any of the secondary endpoints or the time to the primary endpoint components. CONCLUSION: Among patients with heart failure and a CIED, RM using weekly downloads and a formalized follow up approach does not improve outcomes.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Consulta Remota , Adulto , Anciano , Anciano de 80 o más Años , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Dispositivos de Terapia de Resincronización Cardíaca , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Cooperación del Paciente
11.
Eur Heart J ; 38(19): 1485-1494, 2017 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-28065904

RESUMEN

AIMS: Previous studies have identified sex disparities in the use of cardiac resynchronization therapy (CRT) and implantable cardioverter defibrillators (ICD), although the basis of underutilization in women remains poorly understood. The aim of this study was to assess sex differences in patterns of CRT use with our without ICD. METHODS AND RESULTS: In this cross-sectional study using the National Inpatient Sample database we identified 311 009 patients undergoing CRT implantation in the United States between 2006 and 2012. Demographic and clinical characteristics were compared between men and women undergoing CRT implantation, with special attention to clinical predictors of left ventricular reverse remodelling (CRT response, score range: 0-4) and reduced ICD efficacy (score range: 0-7). When compared to men, women undergoing CRT implantation were significantly more likely to have ≥ 3 predictors of CRT response (47.3 vs. 33.2%, P < 0.001) and less likely to have ≥3 predictors of reduced ICD efficacy (27.0 vs. 37.3%, P < 0.001). Despite this, men were significantly more likely to undergo CRT with ICD (CRT-D) as the type of CRT (88.6 vs. 80.1% of all CRT implants). Compared to those with the greatest likelihood of CRT response (score ≥ 3), those with the least likelihood of CRT response had a significant decreased odds of CRT-D implant (adj odds ratio 0.27 [0.24-0.31], P < 0.001), with a greater decreased odds in women compared to men (P, for sex interaction <0.001). The difference in the % of CRT-D implant in men vs. women increased over the study period (P, sex Δ time trend = 0.012). CONCLUSION: In this large, contemporary cohort, sex differences in CRT-D implantation were inversely related to predicted CRT efficacy and have increased over time. Future efforts to narrow the gap in CRT-D implantation in men and women may help better align device selection with those most likely to benefit.


Asunto(s)
Terapia de Resincronización Cardíaca/estadística & datos numéricos , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Adolescente , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Disparidades en Atención de Salud , Insuficiencia Cardíaca/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Distribución por Sexo , Estados Unidos/epidemiología , Adulto Joven
12.
Eur Heart J ; 38(27): 2122-2128, 2017 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-28329322

RESUMEN

Aims: Cardiac resynchronization therapy (CRT) device implantation has been shown to reduce morbidity and mortality in selected patients with heart failure. We sought to investigate the utilization and in-hospital complications of cardiac resynchronization therapy defibrillator (CRT-D) and pacemaker (CRT-P) implantations in the United States from 2003 to 2013. Methods and results: Patients receiving CRT-D or CRT-P were identified in the National Inpatient Sample database (NIS), using the International Classification of Diseases-Ninth Revision-Clinical Modification procedure codes. Annual implantation rates, patient demographics, co-morbidities, in-hospital complications, and length of stay were analysed. From 2003 to 2013, an estimated total of 439 010 (95% CI: 406 723-471 296) inpatient CRT implantations were performed in the U.S. The median age of patients was 72 and 71% were male. Overall, 6.1% had at least one complication. During the study period, comorbidity index and overall complication rate increased (P = 0.002 and P = 0.01, respectively). Mortality and length of stay showed no significant trend. Predictors of complications included: age 65 and older, female sex (OR: 1.19; 95% CI: 1.12-1.27), Deyo-Charlson Comorbidity Index, and elective admission (OR: 0.61; 95% CI: 0.57-0.66). Conclusion: From 2003 to 2013, the severity of comorbid conditions increased and a rising trend was observed in the rate of periprocedural complications among patients undergoing CRT in the United States. In-hospital mortality and length of stay showed no uniform trend.


Asunto(s)
Terapia de Resincronización Cardíaca/tendencias , Insuficiencia Cardíaca/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Insuficiencia Cardíaca/mortalidad , Mortalidad Hospitalaria , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias , Estudios Retrospectivos , Estados Unidos/epidemiología , Adulto Joven
13.
Int Heart J ; 59(5): 1002-1007, 2018 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-30158380

RESUMEN

Several studies have reported that the left ventricular (LV) lead implant success rate ranges between 88.0% and 92.4%. Coronary venous anatomy differs among patients thus, necessitating multiple types of leads. To date, the implant success rate among Japanese patients utilizing a pre-specified family LV leads (including bipolar and quadripolar) is not well known. The Attain Success Japan Study enrolled patients indicated for a de novo or an upgrade cardiac resynchronization therapy implant. Patients were followed for 3 months, and the implant success rates with Medtronic Attain family LV leads as well as the incidence of complications related to the LV lead were evaluated.Three hundred 53 patients were enrolled from 29 sites in Japan; 346 patients had LV lead implant attempts. The LV lead was successfully implanted in 336 patients (97.1%). Bipolar and quadripolar LV lead implants were successful in 97.2% and 99.2% of patients, respectively (P = 0.43). Four complications (1.2%) related to the LV leads were reported; all of which occurred in patients receiving bipolar LV leads. The quadripolar LV leads were more frequently implanted in the apical segment compared with bipolar leads (21.6% versus 3.8%, P < 0.01). This study demonstrated a high implant success rate and a low LV lead-related complication rate, regardless of bipolar, or quadripolar in a Japanese cohort of patients.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/tendencias , Terapia de Resincronización Cardíaca/efectos adversos , Ventrículos Cardíacos/fisiopatología , Cuidados Posteriores , Anciano , Anciano de 80 o más Años , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Circulación Coronaria/fisiología , Diseño de Equipo/efectos adversos , Diseño de Equipo/estadística & datos numéricos , Femenino , Ventrículos Cardíacos/cirugía , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos
14.
Circulation ; 133(3): 273-81, 2016 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-26635400

RESUMEN

BACKGROUND: Candidates for cardiac resynchronization therapy (CRT) receive either a biventricular pacemaker or a biventricular pacemaker with an implantable cardioverter-defibrillator (CRT-D). Optimal device selection remains challenging because the benefit of implantable cardioverter-defibrillator therapy may not be uniform, particularly in patients at competing risk of nonsudden death. METHODS AND RESULTS: In this serial cross-sectional study using the National Inpatient Sample database, we identified 311,086 admissions associated with CRT implant between 2006 to 2012. CRT-D was the most common device type (86.1%), including in patients ≥ 75 years of age with ≥ 5 Elixhauser comorbidities (75.5%). Multivariate predictors of CRT-D implant included demographic, clinical, and geographic factors: prior ventricular arrhythmia (rate ratio [RR], 1.14; 95% CI, 1.13-1.14), ischemic heart disease (RR, 1.11; 95% CI, 1.10-1.11), male sex (RR, 1.10; 95% CI, 1.09-1.10), black race (RR, 1.06; 95% CI: 1.04-1.07), and Northeast geographic region (RR, 1.06; 95% CI, 1.04-1.09). There was significant interhospital variation in the use of CRT-D (10-90 percentile range, 72.9%-98.0% CRT-D). CONCLUSIONS: The majority of patients in this contemporary US cohort underwent implantation of CRT-D. Predictors of CRT-D implant included demographic, clinical, and geographic factors. In patient subgroups predicted to have an attenuated benefit from implantable cardioverter-defibrillator therapy (older adults with multiple comorbidities), CRT-D remained the dominant device type. An improved understanding of the determinants of device selection may aid in decision making and ultimately better align patient risk with device benefit at the time of CRT implantation.


Asunto(s)
Terapia de Resincronización Cardíaca/estadística & datos numéricos , Terapia de Resincronización Cardíaca/tendencias , Desfibriladores Implantables/estadística & datos numéricos , Desfibriladores Implantables/tendencias , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Terapia de Resincronización Cardíaca/métodos , Estudios de Cohortes , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estados Unidos/epidemiología , Adulto Joven
15.
Am Heart J ; 189: 48-58, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28625381

RESUMEN

OBJECTIVES: We examined trends in CRT utilization overall and by sex and race and to assess whether CRT use is associated with a reduction in HF hospitalization and mortality. BACKGROUND: It is unknown whether underutilization and race/sex-based differences in cardiac resynchronization therapy (CRT) use have persisted. The association between CRT and heart failure (HF) hospitalization and mortality in real-world practice remains unclear. METHODS: We linked 72,008 HF patients from 388 hospitals participating in Get With The Guidelines HF eligible for CRT with Centers for Medicare & Medicaid Services data to assess CRT utilization trends, HF hospitalization rates, and all-cause mortality. RESULTS: From 2005-2014, 18,935 (26.3%) eligible patients had CRT in place, implanted, or prescribed. The majority were male (60.0%) and white (61.9%). CRT utilization increased during the study period (P = .0002) especially in the early period. Women were less likely to receive CRT, and this difference increased over time (interaction P = .0037) despite greater mortality risk reduction (interaction P = .0043). Black patients were less likely than white patients to have CRT throughout the study period (adjusted hazard ratio (HR) 0.79; 95% CI 0.74-0.85). Patients with CRT implanted during the index hospitalization had lower mortality (adjusted HR 0.65; 95% CI 0.59-0.71) and were less likely to be readmitted for HF than patients without CRT (adjusted HR 0.64; 95% CI 0.58-0.71). CONCLUSIONS/RELEVANCE: CRT use has increased in all populations, but it remains underutilized. CRT remains more common among white than black HF patients, and women were less likely than men to receive CRT despite deriving greater benefit.


Asunto(s)
Terapia de Resincronización Cardíaca/estadística & datos numéricos , Insuficiencia Cardíaca/terapia , Hospitalización/tendencias , Pacientes Internos , Anciano , Causas de Muerte/tendencias , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
16.
J Nucl Cardiol ; 24(1): 122-129, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-26563336

RESUMEN

BACKGROUND: Mechanical left ventricular dyssynchrony (MLVD) might contribute in the therapeutic decision-making in patients with heart failure (HF) prior to cardiac resynchronization therapy (CRT). Our aim was to assess MLVD in patients with HF prior to implantable cardioverter-defibrillator (ICD) compared to patients with CRT-D. METHODS: In a prospective study, patients with LVEF ≤ 35% who were scheduled for ICD or CRT-D, underwent gated SPECT myocardial perfusion imaging with technetium 99m sestamibi within 3 months prior procedure. MLVD was measured by phase analysis. RESULTS: The study cohort consisted of 143 patients, 71 with ICD and 72 with CRT-D. Age 68.3 ± 11 and LVEF 24 ± 6%. Phase standard deviation (SD) was 62.5 ± 18 and 59.7 ± 20 (P = NS), respectively. During follow-up of 23.7 ± 12.1 months, there were 10 vs 14 cardiac death in ICD and CRT-D, respectively (P = NS), hospitalization for HF, in 34 vs 53 (P < .001). In multivariate analysis, Phase SD was the independent predictor for cardiac death [HR 2.66 (95% CI 1.046-6.768), P = .04]. Kaplan-Meier curves of phase SD of 60° significantly identified ICD patients with and without cardiac deaths and hospitalization for HF exacerbation. CONCLUSIONS: MLVD by phase SD can identify patients with cardiac events and predict cardiac death in patients treated with ICD.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables/estadística & datos numéricos , Imagen de Acumulación Sanguínea de Compuerta/estadística & datos numéricos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/prevención & control , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Causalidad , Terapia Combinada , Comorbilidad , Muerte Súbita Cardíaca/epidemiología , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Incidencia , Israel/epidemiología , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Pronóstico , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Tasa de Supervivencia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen
17.
Europace ; 19(5): 705-711, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28011795

RESUMEN

There are limited data about the management of patients presenting for elective generator replacements in the setting of previously implanted cardiac resynchronization therapy (CRT) devices that are nearing end-of-life. The individual patient's clinical status and concomitant morbidities may evolve so that considerations may include not only replacement of the pulse generator, but also potentially changing the type of device [e.g. downgrading CRT-defibrillator (CRT-D) to CRT-pacemaker (CRT-P) or ICD or upgrading of CRT-P to CRT-D]. Moreover, the clinical evidence for CRT-D/CRT-P implantation may change over time, with ongoing research and availability of new trial data. In this review we discuss the ethical, clinical and financial implications related to CRT generator replacements and the need for additional clinical trials to better understand which patients should undergo CRT device downgrading or upgrading at the time of battery depletion.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Toma de Decisiones Clínicas/métodos , Remoción de Dispositivos/estadística & datos numéricos , Análisis de Falla de Equipo/métodos , Insuficiencia Cardíaca/prevención & control , Anciano , Análisis de Falla de Equipo/estadística & datos numéricos , Medicina Basada en la Evidencia , Femenino , Humanos , Masculino , Resultado del Tratamiento
18.
Europace ; 19(4): 573-580, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28431062

RESUMEN

AIMS: Left-ventricular (LV) scarring may be associated with a poor response to cardiac resynchronization therapy (CRT). The automatic analysis of myocardial perfusion single-photon emission computed tomography (MP-SPECT) may provide objective quantification of LV scarring. We investigated the impact of LV scarring determined by an automatic analysis of MP-SPECT on short-term LV volume response as well as long-term outcome. METHODS AND RESULTS: We studied consecutive 51 patients who were eligible to undergo 99mTc-MIBI MP-SPECT both at baseline and 6 months after CRT (ischaemic cardiomyopathies 31%). Quantitative perfusion SPECT was used to evaluate the defect extent (an index of global scarring) and the LV 17-segment regional uptake ratio (an inverse index of regional scar burden). The primary outcome was the composite of overall mortality or first hospitalization for worsening heart failure. A high global scar burden and a low mid/basal inferolateral regional uptake ratio were associated with volume non-responders to CRT at 6 months. The basal inferolateral regional uptake ratio remained as a predictor of volume non-response after adjusting for the type of cardiomyopathy. During a median follow-up of 36.1 months, the outcome occurred in 28 patients. The patients with a low basal inferolateral regional uptake ratio with a cutoff value of 57% showed poor prognosis (log-rank P= 0.006). CONCLUSION: The scarring determined by automatic analysis of MP-SPECT images may predict a poor response to CRT regardless of the pathogenesis of cardiomyopathy. The basal inferolateral scar burden in particular may have an adverse impact on long-term prognosis.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Anciano , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Causalidad , Comorbilidad , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Japón/epidemiología , Estudios Longitudinales , Masculino , Imagen de Perfusión Miocárdica/métodos , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Aturdimiento Miocárdico/diagnóstico por imagen , Aturdimiento Miocárdico/mortalidad , Aturdimiento Miocárdico/prevención & control , Prevalencia , Pronóstico , Radiofármacos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Análisis de Supervivencia , Tomografía Computarizada de Emisión de Fotón Único/métodos , Resultado del Tratamiento , Disfunción Ventricular Izquierda/prevención & control
19.
Europace ; 19(5): 824-830, 2017 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339577

RESUMEN

Aims: Sarcoidosis with cardiac involvement is a rare pathological condition, and therefore cardiac resynchronization therapy (CRT) for patients with cardiac sarcoidosis is even further rare. We aimed to clarify the clinical features of patients with cardiac sarcoidosis who received CRT. Methods and results: We retrospectively reviewed the clinical data on CRT at three cardiovascular centres to detect cardiac sarcoidosis patients. We identified 18 (8.9%) patients with cardiac sarcoidosis who met the inclusion criteria out of 202 with systolic heart failure who received CRT based on the guidelines. The majority of the patients were female [15 (83.3%)] and underwent an upgrade from a pacemaker or implantable cardioverter defibrillator [13 (72.2%)]. We found 1 (5.6%) cardiovascular death during the follow-up period (mean ± SD, 4.7 ± 3.0 years). Seven (38.9%) patients had a composite outcome of cardiovascular death or hospitalization from worsening heart failure within 5 years after the CRT. Twelve (66.7%) patients had a history of sustained ventricular arrhythmias or those occurring after the CRT. Among the overall patients, no significant improvement was found in either the end-systolic volume or left ventricular ejection fraction (LVEF) 6 months after the CRT. A worsening LVEF was, however, more likely to be seen in 5 (27.8%) patients with ventricular arrhythmias after the CRT than in those without (P = 0.04). An improved clinical composite score was seen in 10 (55.6%) patients. Conclusions: Cardiac sarcoidosis patients receiving CRT may have poor LV reverse remodelling and a high incidence of ventricular arrhythmias.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/mortalidad , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Sarcoidosis/epidemiología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/prevención & control , Anciano , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Cardiomiopatías/terapia , Comorbilidad , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Femenino , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Sarcoidosis/terapia , Resultado del Tratamiento
20.
Pacing Clin Electrophysiol ; 40(3): 301-309, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28083969

RESUMEN

BACKGROUND: Left ventricular end-systolic volume (LVESV) changes at 6 months and clinical status are useful for assessing responses to cardiac resynchronization therapy (CRT). Regression of the LVESV following CRT has not been described beyond 6 months. This study aimed to assess the proportion, predictors, and clinical outcomes of responders whose LVESVs had regressed. METHODS: We retrospectively analyzed 104 consecutive CRT patients. A responder was defined as a patient with a relative reduction in the LVESV ≥15% at 6 months after CRT. Fifty-six responders participated in this study. A transient responder was defined as a responder without a relative reduction in the LVESV ≥15% at 2 years after CRT or who died of cardiac events during the 24-month follow-up period. RESULTS: Of the 56 responders, 16 (29%) were transient responders. Multivariable logistic regression analysis showed that chronic atrial fibrillation (odds ratio [OR] = 19.2, 95% confidence interval [CI] [1.93, 190], P = 0.012) and amiodarone usage (OR = 60.9, 95% CI [4.18, 886], P = 0.003) were independent predictors of transient responses. Hospitalizations for heart failure were significantly higher among the transient responders than among the lasting responders during a mean follow-up period of 7.6 years (log-rank P < 0.001), and all-cause mortality tended to be higher among the transient responders (log-rank P = 0.093). CONCLUSIONS: One-third of the responders were transient responders at 2 years after CRT, and their long-term prognoses were poor. Careful attention should be paid to maintain the reduction in LVESV especially in patients with chronic AF.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Volumen Sistólico , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/prevención & control , Anciano , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Causalidad , Enfermedad Crónica , Comorbilidad , Supervivencia sin Enfermedad , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Japón/epidemiología , Estudios Longitudinales , Masculino , Prevalencia , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Tasa de Supervivencia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA