RESUMEN
INTRODUCTION: Some studies report that assessing regional 123I-cardiac MIBG uptake can aid in the diagnosis of Lewy body disease, but others report heterogeneity in healthy controls. We aimed to evaluate regional cardiac MIBG uptake patterns in healthy older adults and patients with dementia. METHODS: 31 older adults with normal cognition, 15 Alzheimer's disease (AD), and 17 Dementia with Lewy bodies (DLB) patients were recruited. 5 individuals had previous myocardial infarction. Participants with sufficient cardiac uptake for regional SPECT analysis (29/31 controls, 15/15 AD, 5/17 DLB) had relative uptake pattern recorded. Controls were assessed for risk of future cardiovascular events using QRISK2, a validated online tool. RESULTS: In controls uptake was reduced in the inferior wall (85%), apex (23%), septum (15%), and lateral wall (8%). AD and DLB showed similar patterns to controls. Lung or liver interference was present in 61% of cases. Myocardial infarction cases showed regional reductions in uptake, but normal/borderline planar uptake. In controls, there was no relationship between cardiovascular risk score and uptake pattern. CONCLUSIONS: Significant variability of regional cardiac 123I-MIBG uptake is common in cases with normal planar cardiac uptake. Heterogeneity of regional uptake appears non-specific and unlikely to aid in the diagnosis of Lewy body disease.
Asunto(s)
Radioisótopos de Yodo/administración & dosificación , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/normas , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/diagnóstico por imagen , Femenino , Humanos , Radioisótopos de Yodo/uso terapéutico , Enfermedad por Cuerpos de Lewy/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radiofármacos/administración & dosificación , Radiofármacos/uso terapéutico , Sensibilidad y Especificidad , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Reino UnidoRESUMEN
Hybrid imaging procedures such as single-photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/computed tomography (PET/CT) showed a rapid diffusion in recent years because of their high sensitivity, specificity, and accuracy, due to a more accurate localization and definition of scintigraphic findings. However, hybrid systems inevitably lead to an increase in patient radiation exposure because of the added CT component. Effective doses due to the radiopharmaceuticals can be estimated by multiplying the administered activities by the effective dose coefficients, while for the CT component the dose-length product can be multiplied by a conversion coefficient k. However, the effective dose value is subject to a high degree of uncertainty and must be interpreted as a broad, generic estimate of biologic risk. Although the effective dose can be used to estimate and compare the risk of radiation exposure across multiple imaging techniques, clinicians should be aware that it represents a generic evaluation of the risk derived from a given procedure to a generic model of the human body. It cannot be applied to a single individual and should not be used for epidemiologic studies or the estimation of population risks due to the inherent uncertainties and oversimplifications involved. Practical ways to reduce radiation dose to patients eligible for hybrid imaging involve adjustments to both the planning phase and throughout the execution of the study. These methods include individual justification of radiation exposure, radiopharmaceutical choice, adherence to diagnostic reference levels (DLR), patient hydration and bladder voiding, adoption of new technical devices (sensitive detectors or collimators) with new reconstruction algorithms, and implementation of appropriate CT protocols and exposure parameters.
Asunto(s)
Imagen Multimodal/efectos adversos , Medicina Nuclear , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiofármacos/efectos adversos , Humanos , Imagen Multimodal/métodos , Imagen Multimodal/estadística & datos numéricos , Imagen Multimodal/tendencias , Medicina Nuclear/estadística & datos numéricos , Medicina Nuclear/tendencias , Tomografía Computarizada por Tomografía de Emisión de Positrones/efectos adversos , Tomografía Computarizada por Tomografía de Emisión de Positrones/estadística & datos numéricos , Tomografía Computarizada por Tomografía de Emisión de Positrones/tendencias , Edición/estadística & datos numéricos , Edición/tendencias , Radiofármacos/administración & dosificación , Riesgo , Sensibilidad y Especificidad , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/efectos adversos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/tendencias , Tomografía Computarizada por Rayos X/efectos adversosRESUMEN
PURPOSE: To evaluate the diagnostic and clinical value of SPECT/CT compared to the standard algorithm for patients with persistent symptoms after anterior cruciate ligament reconstructions. The standard algorithm uses clinical information, conventional radiographs, MRI and CT scan, while the trial algorithm uses the same information but SPECT/CT in addition. METHODS: In a diagnostic comparative trial three experienced surgeons evaluated 23 consecutive patients with persistent symptoms after ACL reconstruction using first standard and second the trial algorithm with a time interval. Each rater had to establish a diagnosis and therapeutic decision with each algorithm. On MRI, graft continuity, bone marrow edema, chondral and meniscal lesions, femoral notch osteophytes were evaluated. Bone tracer uptake in SPECT/CT was anatomically analyzed and compared with MRI findings. MRI findings and SPECT/CT tracer uptake were correlated using Spearman's rho test. RESULTS: Additional SPECT/CT analysis did not change diagnosis in any case and did not correlate with clinical graft integrity. Treatment decisions remained unchanged as well. Chondral lesions, arthritic changes, meniscal lesions, graft impingement are best visualized in MRI and showed correspondent tracer uptake in SPECT/CT. Tunnel position was well classified with standard CT scan and showed no correlation with SPECT/CT tracer uptake. CONCLUSION: Information derived by SPECT/CT in addition to the standard algorithm using clinical information, X-rays, MRI, and CT scan did not change the diagnosis or treatment plan. There is currently no justification to implement SPECT/CT for patients with persistent symptoms after anterior cruciate ligament reconstructions. LEVEL OF EVIDENCE: Level II: diagnostic comparative study.
Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Algoritmos , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Reconstrucción del Ligamento Cruzado Anterior/estadística & datos numéricos , Humanos , Imagen por Resonancia MagnéticaRESUMEN
Single-photon emission computed tomography images of murine tumors are interpreted as the values of functions on a three-dimensional domain. Motivated by Morse theory, the local maxima of the tumor image functions are analyzed. This analysis captures tumor heterogeneity that cannot be identified with standard measures. Utilizing decreasing sequences of uptake values to filter the images, a modified form of the standard persistence diagrams for 0-dimensional persistent homology as well as novel childhood diagrams are constructed. Applying statistical methods to time series of persistence and childhood diagrams detects heterogeneous uptake of radioactive antibody within tumors over time and distinguishes uptake in two groups of mice injected with different labeled antibodies.
Asunto(s)
Radioisótopos de Indio/farmacocinética , Neoplasias Experimentales/diagnóstico por imagen , Neoplasias Experimentales/metabolismo , Radiofármacos/farmacocinética , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Animales , Transporte Biológico Activo , Línea Celular Tumoral , Biología Computacional , Conceptos Matemáticos , Ratones , Modelos Biológicos , Modelos Estadísticos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricosRESUMEN
BACKGROUND: Performing both single photon emission computerized tomography (SPECT) and coronary computed tomography angiography (CCTA) in patients suspected for coronary artery disease (CAD) leads to increased radiation exposure. We evaluated the need for additional imaging and following implications for radiation exposure of a sequential SPECT/computed tomography (CT) algorithm. METHODS AND RESULTS: 5018 consecutive patients without history of CAD were referred for stress-first SPECT and coronary artery calcium (CAC) scoring. If stress SPECT was abnormal, additional rest SPECT and, if feasible, CCTA were acquired. Stress SPECT was normal in 2617 patients (52%). CCTA was not performed in 1289 of the 2401 patients referred for additional imaging (54%), mainly because of severe CAC (47%) or fast/irregular heart rate (22%). 642 patients with abnormal SPECT underwent CCTA, which excluded significant CAD in 378 patients (59%). Mean radiation dose was 4.5 ± 0.3 mSv for stress-only imaging and 13.2 ± 3.3 mSv for additional imaging (P < 0.001). CONCLUSIONS: Half of the patients do not require additional imaging in our sequential SPECT/CT algorithm, which is accompanied with low radiation exposure. CCTA cannot be performed in half of the patients who undergo additional imaging because of (relative) contra-indications. CCTA is able to correct for false-positive SPECT findings in our algorithm.
Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Uso Excesivo de los Servicios de Salud/estadística & datos numéricos , Exposición a la Radiación/prevención & control , Exposición a la Radiación/estadística & datos numéricos , Derivación y Consulta/estadística & datos numéricos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Progresión de la Enfermedad , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Evaluación de Necesidades , Países Bajos/epidemiología , Prevalencia , Factores de Riesgo , Técnica de Sustracción/estadística & datos numéricos , Revisión de Utilización de RecursosRESUMEN
RATIONALE: 123I-mIBG planar image heart-to-mediastinum ratios effectively risk-stratify heart failure (HF) patients. The value of single-photon emission computed tomographic (SPECT) imaging for identifying increased risk of ventricular arrhythmias is less clear. This study sought to determine if findings from simultaneous interpretation of 123I-mIBG and 99mTc-tetrofosmin SPECT are predictive of arrhythmic events (ArEs). METHODS: 123I-mIBG SPECT images from 622 patients with ischemic HF were presented in standard displays alongside 99mTc-tetrofosmin images. Consensus interpretations using a 17-segment model produced summed scores. Cox proportional hazards analyses related findings to adjudicated ArEs over 2 years. RESULTS: 471 patients had images adequate for total 17-segment scoring. There were 48 ArEs (10.2%). Neither 123I-mIBG nor 99mTc-tetrofosmin SPECT summed scores were univariate predictors. On multivariate proportional hazards analysis, the 123I-mIBG SPECT score was independently predictive of ArEs (HR: 0.975, 95% CI 0.951-0.999, P = 0.042), but HR<1 indicated that risk decreased with increasing score. This occurred because patients with intermediately abnormal SPECT studies had a higher likelihood of ArEs compared to patients with extensive abnormalities. CONCLUSIONS: The presumption of a monotonic increase in ArE risk with increasing summed 123I-mIBG SPECT score may not be correct as ischemic HF patients with abnormalities of intermediate extent appear at highest risk.
Asunto(s)
3-Yodobencilguanidina , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/mortalidad , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Compuestos Organofosforados , Compuestos de Organotecnecio , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Causalidad , Comorbilidad , Femenino , Humanos , Incidencia , Internacionalidad , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/mortalidad , Pronóstico , Radiofármacos , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Tasa de SupervivenciaRESUMEN
BACKGROUND: Attenuation corrected computed tomography (CTAC) is often performed to improve the specificity of single-photon emission tomography imaging. Extracardiac incidental findings are frequently observed. It is unclear whether these findings have any prognostic value. METHODS: Consecutive patients (n = 1139) at a tertiary care center were retrospectively evaluated for incidental findings on CTAC. Clinically significant incidental findings were defined as findings warranting physician follow-up. Information regarding subsequent resource utilization was obtained by chart review. Cox proportional hazard model adjusted for demographic and clinical variables was used to evaluate association of these incidental findings with all-cause and cancer-specific mortality. RESULTS: A total of 135 (12%) patients with incidental findings were identified, 83 of whom (68%) were newly diagnosed. Lung nodules were the most common finding, present in 92 (68%) patients. Over a median follow-up of 468 days, incidental findings were not significantly associated with increased risk of all-cause mortality (HR 1.34; 95% CI 0.77-2.33, P = 0.29) but was significantly associated with cancer-specific mortality (HR 3.21; 95% CI 1.26-8.14, P = 0.01). This association remained statistically significant when the analysis was limited to newly diagnosed incidental findings. Among patients with incidental findings, follow-up radiographic studies were conducted in 87%, and invasive procedures performed in 32%. Physician office-based follow-up of these findings occurred in 42% of patients and incidental finding-related hospitalization occurred in 14%. CONCLUSIONS: This study shows that incidental findings are common and were associated with all-cause and cancer-specific mortality but only the later remained statistically significant after multivariable adjustment.
Asunto(s)
Artefactos , Técnicas de Imagen Cardíaca/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Neoplasias/diagnóstico por imagen , Neoplasias/mortalidad , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Comorbilidad , Femenino , Humanos , Incidencia , Hallazgos Incidentales , Masculino , Michigan/epidemiología , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Factores de Riesgo , Sensibilidad y Especificidad , Tasa de SupervivenciaRESUMEN
BACKGROUND: [67Ga]Ga-citrate scanning has been used to investigate patients with known or suspected infection for over 50 years, continuing to maintain a clinical niche in many centres. The introduction of single photon emission tomography/computed tomography (SPECT/CT) in addition to planar imaging has improved the specificity of diagnosis. AIM: To examine the experience of modern [67Ga]Ga-citrate scanning in a single tertiary referral centre, considering the diagnostic yield of the study. METHODS: A retrospective audit was undertaken of 100 consecutive [67Ga]Ga-citrate scans at Royal North Shore Hospital, Sydney. Recorded information included patient demographics, clinical information/history, and primary and secondary diagnoses. Subgroup analyses included patients with a confirmed diagnosis of infection or a suspected diagnosis of infection. RESULTS: The median age of patients was 68.5 years. Totally, 39/100 patients undergoing [67Ga]Ga-citrate scanning presented with a confirmed site of infection, with 2/6 patients with infective endocarditis and 5/12 patients with bacteraemia diagnosed with an additional, previously unknown, site of active infection (compared to 1/21 patients without documented bacteraemia). 61/100 patients did not have a confirmed site of infection before [67Ga]Ga-citrate scan (as per clinical history). 34/61 of these patients had a positive scan result for active infection/inflammation. Of 20 patients with a positive blood culture but no suspected site of infection, the source was identified in 9. CONCLUSION: [67Ga]Ga-citrate has diagnostic value in the evaluation of complex patients with high-risk infection. High diagnostic yield is demonstrated in patients with bacteraemia with or without a confirmed site of infection, particularly when combined with SPECT/CT.
Asunto(s)
Radioisótopos de Galio , Centros de Atención Terciaria/estadística & datos numéricos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricosRESUMEN
ABSTRACT: Although the importance of quadriceps femoris function was reported previously, little is known about volume-related factors and their effects on clinical outcomes after total knee arthroplasty (TKA). We sought to determine whether there was a bilateral difference in vastus medialis muscle volume measured on single-photon emission computed tomography-computed tomography (SPECT-CT) in patients who underwent unilateral TKA. We also aimed to determine whether vastus medialis volume was related to osteoarthritis (OA) severity or scintigraphic uptake degree around the knee joint on SPECT-CT. And finally, we attempted to investigate the factors, such as vastus medialis volume and scintigraphic uptake degree, associated with the functional outcomes of TKA.This retrospective study included 50 patients (41 female, 9 male) undergone unilateral TKA due to primary OA. The maximal cross-sectional area of the vastus medialis was measured on axial SPECT-CT images. Scintigraphic uptake degrees and Kellgren-Lawrence (K-L) grade at the tibiofemoral joints were assessed. We compared maximal cross-sectional area of the vastus medialis on SPECT-CT for difference of bilateral lower limbs. We also analyzed the relationship between volume of vastus medialis and scintigraphic uptake measured on SPECT-CT and the severity of OA on conventional radiographs. The clinical outcomes were evaluated using the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index at baseline and at 1 and 2 years after surgery. The relationship between preoperative muscle volume and scintigraphic uptake on SPECT-CT and WOMAC index was analyzed.The amount of muscle volume measured on SPECT-CT was smaller in operated limb in patients who underwent unilateral TKA. Preoperative vastus medialis muscle volume was not related to preoperative OA severity measured on conventional radiographs and scintigraphic uptake on SPECT-CT. However, a decreased vastus medialis muscle volume was related to worse clinical outcomes after TKA (Pâ=â.045), whereas the degree of scintigraphic uptake on SPECT-CT was not associated with postoperative clinical outcomes.Muscle volume of vastus medialis was decreased in the operated knee than in the nonoperated knee, and that was correlated with worse postoperative results. Even if the preoperative volume of vastus medialis were not related to OA severity on conventional radiographs and scintigraphic uptake on SPECT-CT, preservation and improvement of the muscle mass of the knee undergoing TKA is important.
Asunto(s)
Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Complicaciones Posoperatorias/etiología , Músculo Cuádriceps/diagnóstico por imagen , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Humanos , Rodilla/cirugía , Masculino , Persona de Mediana Edad , Ontario/epidemiología , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Pesos y Medidas/instrumentaciónRESUMEN
Many discrepancy in selection of proper filter and its parameters for individual cases exists. The authors investigate the impact of the most common filters on patient NM images with coronary artery disease (CAD), and compare the results with the computerized tomography (CT)-Angio and angiography for accuracy.The investigation initiated by performing various single photon emission computerized tomography (SPECT)/CT scan of the national electrical manufacturers association chest phantoms having hot and cold inserts. Data acquired on GE 670 PRO SPECT/CT; 360Ø, 64 frames, 60âseconds, low energy high resolution (LEHR) 128, low energy general purpose (LEGP) with CT attenuation (120âkV and 170âmA). The images reconstructed with filtered back projection and ITERATIVE ordered-subset expectation maximization utilizing filters; Hann, Butterworth, Metz, Hamming, and Wiener. The Image contrast was calculated to assess absolute nearness of the inserts. Based on the preliminary results, then scans of 92 patients with CAD; 64 males and 28 females, age 41 to 77 years old, who had been reported earlier reprocessed with the nominated filter and were reported by 2 NM expert. The results compared to the earlier reports and to the CT-Angio and angiography.The optimization suggested 3 filters; Wiener (Wi), Metz and Butterworth (But) provide the highest contrast (99- 66.4%) and (81- 32%) for the cold and hot inserts respectively, with the (Wi) filter to be the better option. The reprocessed patients scan with the (Wi) presented an elevated diagnostic accuracy, correlated well with the CT-Angio and angiography results (Pâ<â.001 and râ=â0.79 for [Wi] and Pâ=â.004 and râ=â0.39 for [But]). The percentage of the false negative for moderate to severe CAD cases reported using Wi filter reduced from 27% to 7% and similarly for mild CAD cases from 7% to 1%.It appears the Wiener filter could produce results with the highest contrast for phantom imaging of various cold and hot spheres and for the patient data which is more consistent with angiography results, with much-elevated accuracy in intermediate cases (râ=â0.79 for Wiener and râ=â0.39 for Butterworth vs angiography). However, the optimum parameters obtained for the filters have no relation with the resolution of the imaging system, but the details of the objects could be improved.
Asunto(s)
Angiografía , Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Intensificación de Imagen Radiográfica/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Adulto , Anciano , Angiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen/estadística & datos numéricos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Tomografía Computarizada de Emisión de Fotón Único/métodosRESUMEN
To evaluate the clinical value of NeuroGam software in assessing the brain foci perfusion changes by TC-ECD single photon emission computed tomography/computed tomography (SPECT/CT) brain imaging in patients with Moyamoya Disease (MMD).Seventy-two patients with MMD who underwent superficial temporal artery-middle cerebral artery (STA-MCA) bypass combined with encephalo-duro-myo-synangiosis (EDMS) surgical revascularization were included. Baseline and follow-up TC-ECD SPECT/CT brain scans were performed on all patients at least twice before and after operation. Pre- and post-SPECT dicom images were reoriented into Talairach space using NeuroGam Software package. Additional visual analysis was performed. Differences mean pixel value between pre- and post- operation brain perfusion were assessed with paired t test and McNemar test.Significant differences in the number of hypoperfusion foci were found between visual assessment and NeuroGam aided assessment. More hypoperfusion foci were found by NeuroGam software aided assessment in the frontal, parietal, temporal, occipital lobe, thalamus, basal ganglia and cerebellum before and after surgery (Pâ<â.0001). According to NeuroGam software assessment, the perfusion of frontal, parietal, temporal lobe, anterior and middle cerebral regions on the operative side significantly improved before and after surgery (tâ=â-3.734, tâ=â-3.935, tâ=â-5.099, tâ=â-4.006, tâ=â-5.170, all Pâ<â.001). However, no significant differences were found in the occipital lobe (tâ=â-1.962, Pâ=â.054), thalamus (tâ=â1.362, Pâ=â.177), basal ganglia (tâ=â-2.394, Pâ=â.019), and cerebellum (tâ=â1.383, Pâ=â.171) before and after surgery.The NeuroGam software provides a quantitative approach for monitoring surgical effect of MMD in a variable time (3-12 months after surgery). It could discover the perfusion changes that are neglected in conventional visual assessment.
Asunto(s)
Cisteína/análogos & derivados , Interpretación de Imagen Asistida por Computador/métodos , Enfermedad de Moyamoya/diagnóstico por imagen , Compuestos de Organotecnecio , Radiofármacos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Adolescente , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Revascularización Cerebral/métodos , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Cerebral Media/cirugía , Enfermedad de Moyamoya/cirugía , Periodo Posoperatorio , Periodo Preoperatorio , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Programas Informáticos , Arterias Temporales/cirugía , Resultado del Tratamiento , Adulto JovenRESUMEN
Patient radiation dose and image quality are primary issues in the conduct of nuclear medicine (NM) procedures. A range of protocols are currently used in image acquisition and analysis of quality control (QC) tests, with National Electrical Manufacturers Association (NEMA) methods and protocols widely accepted in providing an accurate description, measurement and report of γ-camera performance parameters. However, no standard software is available for image analysis. Present study compares vendor QC software analysis and three types of software freely downloadable from the internet: NMQC, NM Toolkit and ImageJ-NM Toolkit software. These were used for image analysis of QC tests of γ-cameras based on NEMA protocols including non-uniformity evaluation. Ten non-uniformity QC images were obtained using a dual head γ-camera installed in Trieste General Hospital and then analyzed. Excel analysis was used as the baseline calculation for the non-uniformity test according to NEMA procedures. The results of non-uniformity analysis showed good agreement between the independent types of software and Excel calculations (the average differences were 0.3%, 2.9%, 1.3% and 1.6% for the Useful Field of View (UFOV) integral, UFOV differential, Central Field of View (CFOV) integral and CFOV differential, respectively), while significant differences were detected following analysis using the company QC software when compared with Excel analysis (the average differences were 14.6%, 20.7%, 25.7% and 31.9% for the UFOV integral, UFOV differential, CFOV integral and CFOV differential, respectively). Compared to use of Excel calculations use of NMQC software was found to be in close accord. Variation in results obtained using the three types of software and γ-camera QC software was due to the use of different pixel sizes. It is important to conduct independent analyses tests in addition to using the vendor QC software in order to determine the differences between values.
Asunto(s)
Cámaras gamma/normas , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/normas , Cámaras gamma/estadística & datos numéricos , Humanos , Control de Calidad , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Interpretación de Imagen Radiográfica Asistida por Computador/estadística & datos numéricos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Programas InformáticosRESUMEN
The aim of the study was to evaluate the interest of quantitative bone SPECT-CT in the preoperative assessment of knee osteoarthritis (OA) before unicompartmental knee arthroplasty (UKA).Patients eligible for UKA were prospectively included in 2 centers and underwent a preoperative SPECT-CT. Images were reconstructed with an OSEM, an OSCGM (allowing SUV quantification) and an enhanced OSCGM (containing uptakes to bones) algorithms. Visual analysis and quantification (SUVmax) were performed for each compartment (medial compartment [MC], lateral compartment [LC], and patellofemoral compartment [PFC]). Clinical data were preoperatively assessed. The gold standard was the per-operative OA staging (International Cartilage Repair Society [ICRS] scale). Spearman's correlation coefficient was used for correlations. Sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and accuracy of SPECT-CT were assessed.One hundred three patients (50 women, 53 men, mean ageâ=â64.5â±â10.3 y/o, 120 preoperative knees) were analyzed. There was no correlation between SUVmax and clinical data. There was a correlation between ICRS staging and SUVmax with both OSCGM (MC [rsâ=â0.25], LC [rsâ=â0.51], and PFC [rsâ=â0.27]), and enhanced OSCGM, except in the PFC (MC [rsâ=â0.22], LC [rsâ=â0.62], and PFC [rsâ=â0.03]). The Se, Sp, PPV, NPV, and accuracy of SPECT-CT were, respectively, 0.99, 0.67, 0.98, 0.80, 0.97 for the MC; 0.50, 0.85, 0.42, 0.89, 0.79 for the LC; and 0.23, 0.86, 0.50, 0.64, 0.62 for the PFC.Bone SPECT-CT SUVmax is correlated with per-operative OA staging. Despite the low sensitivity of SPECT-CT in the LC, its high specificity in the LC should prompt the surgeon to be vigilant before UKA surgery.
Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/diagnóstico por imagen , Cuidados Preoperatorios/métodos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Anciano , Cartílago Articular/diagnóstico por imagen , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Valor Predictivo de las Pruebas , Periodo Preoperatorio , Sensibilidad y Especificidad , Estadísticas no ParamétricasRESUMEN
OBJECTIVES: The aim of this study was to conduct a nationwide survey of computed tomography (CT) doses for a wide range of PET-CT and single photon emission computed tomography-computed tomography (SPECT-CT) imaging procedures, with the aim of generating proposed UK national diagnostic reference levels (NDRLs). METHODS: CT protocol and dosimetry data for three PET-CT and seven SPECT-CT examinations were gathered from centres across the UK. Data were divided according to CT purpose (attenuation correction, localization or diagnostic) and third quartile values of scanner average dose metrics were used to generate suggested NDRLs for a range of examination and CT purpose combinations. Achievable doses were also established from the median of the dose distributions. RESULTS: Data were obtained from 47 centres, allowing suggested NDRLs to be produced for fluorine-18-fluorodeoxyglucose half-body PET-CT, and parathyroid, post-thyroid ablation, meta-iodobenzylguanidine/octreotide, cardiac and bone SPECT-CT examinations.Variations in dose of up to a factor of 35 were observed for a given examination/CT purpose combination. For fluorine-18-fluorodeoxyglucose half-body PET-CT examination dose levels for the three CT purposes overlapped, which highlights the variability in the way in which CT purposes are interpreted across the UK. This lack of standardization is believed to be the largest contributor to the dose variations that were observed. The survey highlighted the need for targeted optimization work in many centres. CONCLUSION: Suggested UK NDRLs and achievable doses for six common PET-CT and SPECT-CT examinations have been established as a result of this study.
Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones/estadística & datos numéricos , Dosis de Radiación , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Encuestas y Cuestionarios , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Estándares de Referencia , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/normas , Reino UnidoRESUMEN
The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from â¼6% in the lower count images to â¼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately.