Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 987
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Urol ; 211(3): 445-454, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38134235

RESUMEN

PURPOSE: There are limited data on ablation effects of thulium fiber laser (TFL) settings with varying stone composition. Similarly, little is known surrounding the photothermal effects of TFL lithotripsy regarding the chemical and structural changes after visible char formation. We aim to understand the TFL's ablative efficiency across various stone types and laser settings, while simultaneously investigating the photothermal effects of TFL lithotripsy. MATERIALS AND METHODS: Human specimens of calcium oxalate monohydrate, calcium oxalate dihydrate, uric acid, struvite, cystine, carbonate apatite, and brushite stones were ablated using 13 prespecified settings with the Coloplast TFL Drive. Pre- and postablation mass, ablation time, and total energy were recorded. Qualitative ablative observations were recorded at 1-minute intervals with photographs and gross description. Samples were analyzed with Fourier-transform infrared spectroscopy pre- and postablation and electron microscopy postablation to assess the photothermal effects of TFL. RESULTS: Across all settings and stone types, 0.05 J × 1000 Hz was the best numerically efficient ablation setting. When selected for more clinically relevant laser settings (ie, 10-20 W), 0.2 J × 100 Hz, short pulse was the most numerically efficient setting for calcium oxalate dihydrate, cystine, and struvite stones. Calcium oxalate monohydrate ablated with the best numerical efficiency at 0.4 J × 40 Hz, short pulse. Uric acid and carbonate apatite stones ablated with the best numerical efficiency at 0.3 J × 60 Hz, short pulse. Brushite stones ablated with the best numerical efficiency at 0.5 J × 30 Hz, short pulse. Pulse duration impacted ablation effectiveness greatly with 6/8 (75%) of inadequate ablations occurring in medium or long pulse settings. The average percent of mass lost during ablation was 57%; cystine stones averaged the highest percent mass lost at 71%. Charring was observed in 36/91 (40%) specimens. Charring was most often seen in uric acid, cystine, and brushite stones across all laser settings. Electron microscopy of char demonstrated a porous melting effect different to that of brittle fracture. Fourier-transform infrared spectroscopy of brushite char demonstrated a chemical composition change to amorphous calcium phosphate. CONCLUSIONS: We describe the optimal ablation settings based on stone composition, which may guide urologists towards more stone-specific care when using thulium laser for treating renal stones (lower energy settings would be safer for ureteral stones). For patients with unknown stone composition, lasers can be preset to target common stone types or adjusted based on visual cues. We recommend using short pulse for all TFL lithotripsy of calculi and altering the settings based on visual cues and efficiency to minimize the charring, an effect which can make the stone refractory to further dusting and fragmentation.


Asunto(s)
Apatitas , Fosfatos de Calcio , Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Cálculos Urinarios , Humanos , Cálculos Urinarios/cirugía , Cálculos Urinarios/química , Tulio/química , Estruvita , Cistina , Ácido Úrico , Cálculos Renales/terapia , Rayos Láser , Litotripsia por Láser/métodos , Láseres de Estado Sólido/uso terapéutico
2.
BJU Int ; 134(2): 276-282, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38797721

RESUMEN

OBJECTIVES: To address the paucity of literature comparing outcomes achieved with utilisation of the high-power holmium:yttrium-aluminium-garnet (Ho:YAG) laser with MOSES technology vs those achieved with the thulium fibre laser (TFL) in mini-percutaneous nephrolithotomy (PCNL). METHODS: A retrospective review was performed of patients undergoing supine mini-PCNL between August 2021 and May 2023. Exclusion criteria were urinary diversion, simultaneous utilisation of >1 laser platform, use of any other form of fragmentation, and ureteric stones. The Ho:YAG platform (Lumenis Pulse P120H™ with MOSES technology, 120W; Boston Scientific®) and the TFL (Soltive SuperPulsed Thulium Fibre [SPTF], 60W; Olympus®) were compared. Data on stone-free rate (SFR) were determined by computed tomography performed on the first postoperative day and presented as absence of stone fragments, no fragments larger than 2 mm, or no fragments larger than 4 mm. RESULTS: A total of 100 patients met the inclusion criteria, 51 mini-PCNLs with the Ho:YAG laser and 49 with the SPTF laser. No significant differences in demographics or stone characteristics were detected between the two groups. The Ho:YAG laser utilised less energy and time, resulting in higher ablation efficiency (P < 0.05) and less total operating time (P < 0.05). Overall, there was no difference in SFR in any category between the Ho:YAG group and the SPTF group (no fragments: relative risk [RR] 0.81, 95% confidence interval [CI] 0.59-1.12, P = 0.21; fragments <2 mm: RR 0.86, 95% CI 0.67-1.10, P = 0.23; fragments <4 mm: RR 0.96, 95% CI 0.80-1.15, P = 0.67). CONCLUSIONS: Although we observed an equivalent postoperative SFR, this study supports a shorter operating time and greater intra-operative laser efficiency with the Ho:YAG laser over the SPTF laser in mini-PCNL.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Nefrolitotomía Percutánea , Tulio , Humanos , Femenino , Láseres de Estado Sólido/uso terapéutico , Masculino , Nefrolitotomía Percutánea/métodos , Nefrolitotomía Percutánea/instrumentación , Tulio/uso terapéutico , Estudios Retrospectivos , Persona de Mediana Edad , Cálculos Renales/cirugía , Adulto , Resultado del Tratamiento , Posición Supina , Anciano , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación
3.
BJU Int ; 133(2): 223-230, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37942684

RESUMEN

OBJECTIVES: To explore the optimal laser settings and treatment strategies for thulium fibre laser (TFL) lithotripsy, namely, those with the highest treatment efficiency, lowest thermal injury risk, and shortest procedure time. MATERIALS AND METHODS: An in vitro kidney model was used to assess the efficacy of TFL lithotripsy in the upper calyx. Stone ablation experiments were performed on BegoStone phantoms at different combinations of pulse energy (EP ) and frequency (F) to determine the optimal settings. Temperature changes and thermal injury risks were monitored using embedded thermocouples. Experiments were also performed on calcium oxalate monohydrate (COM) stones to validate the optimal settings. RESULTS: High EP /low F settings demonstrated superior treatment efficiency compared to low EP /high F settings using the same power. Specifically, 0.8 J/12 Hz was the optimal setting, resulting in a twofold increase in treatment efficiency, a 39% reduction in energy expenditure per unit of ablated stone mass, a 35% reduction in residual fragments, and a 36% reduction in total procedure time compared to the 0.2 J/50 Hz setting for COM stones. Thermal injury risk assessment indicated that 10 W power settings with high EP /low F combinations remained below the threshold for tissue injury, while higher power settings (>10 W) consistently exceeded the safety threshold. CONCLUSIONS: Our findings suggest that high EP /low F settings, such as 0.8 J/12 Hz, are optimal for TFL lithotripsy in the treatment of COM stones. These settings demonstrated significantly improved treatment efficiency with reduced residual fragments compared to conventional settings while keeping the thermal dose below the injury threshold. This study highlights the importance of using the high EP /low F combination with low power settings, which maximizes treatment efficiency and minimizes potential thermal injury. Further studies are warranted to determine the optimal settings for TFL for treating kidney stones with different compositions.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Humanos , Tulio , Litotripsia por Láser/efectos adversos , Litotripsia por Láser/métodos , Láseres de Estado Sólido/uso terapéutico , Cálculos Renales/terapia , Riñón
4.
World J Urol ; 42(1): 79, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38353743

RESUMEN

PURPOSE: To identify laser settings and limits applied by experts during laser vaporization (vapBT) and laser en-bloc resection of bladder tumors (ERBT) and to identify preventive measures to reduce complications. METHODS: After a focused literature search to identify relevant questions, we conducted a survey (57 questions) which was sent to laser experts. The expert selection was based on clinical experience and scientific contribution. Participants were asked for used laser types, typical laser settings during specific scenarios, and preventive measures applied during surgery. Settings for a maximum of 2 different lasers for each scenario were possible. Responses and settings were compared among the reported laser types. RESULTS: Twenty-three of 29 (79.3%) invited experts completed the survey. Thulium fiber laser (TFL) is the most common laser (57%), followed by Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) (48%), continuous wave (cw) Thulium:Yttrium-Aluminium-Garnet (Tm:YAG) (26%), and pulsed Tm:YAG (13%). Experts prefer ERBT (91.3%) to vapBT (8.7%); however, relevant limitations such as tumor size, number, and anatomical tumor location exist. Laser settings were generally comparable; however, we could find significant differences between the laser sources for lateral wall ERBT (p = 0.028) and standard ERBT (p = 0.033), with cwTm:YAG and pulsed Tm:YAG being operated in higher power modes when compared to TFL and Ho:YAG. Experts prefer long pulse modes for Ho:YAG and short pulse modes for TFL lasers. CONCLUSION: TFL seems to have replaced Ho:YAG and Tm:YAG. Most laser settings do not differ significantly among laser sources. For experts, continuous flow irrigation is the most commonly applied measure to reduce complications.


Asunto(s)
Aluminio , Tulio , Neoplasias de la Vejiga Urinaria , Itrio , Humanos , Tulio/uso terapéutico , Neoplasias de la Vejiga Urinaria/cirugía , Rayos Láser , Tecnología
5.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613608

RESUMEN

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Holmio , Tulio , Ureteroscopía , Estudios Prospectivos , Cálculos Renales/cirugía , Rayos Láser
6.
World J Urol ; 42(1): 444, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060790

RESUMEN

PURPOSE: To assess the learning curve of Thulium Fiber Laser Enucleation of prostate (ThuFLEP) of a single surgeon inexperienced in laser endoscopic enucleation of prostate (EEP). METHODS: We retrospectively analyzed all patients with benign prostate hyperplasia undergoing ThuFLEP at our center between January 2022 and August 2023 by one surgeon. Inclusion criteria were International Prostate Symptom Score > 7, prostate volume < 200 g, and maximal urinary flow rate < 15 mL/s. The surgeon was inexperienced in laser EEP and trained by watching educational videos of ThuFLEP before starting to perform the procedure under mentoring during the first 4 cases. Procedural data (enucleation and morcellation efficiency, complications) and functional results up to 3 months were evaluated. Patients were divided into 4 cohorts of 20 consecutive cases to evaluate outcomes evolution throughout time. RESULTS: The mean age of the patients was 69.9 years (SD 7.8) and mean prostate volume was 89.9 g (SD 25.8). Preoperative functional parameters were comparable between the groups. Mean enucleation efficiency (EE) ratio and morcellation efficiency (ME) ratio reached respectively 0.78 g/min (SD 0.55) and 2.49 g/min (SD 1.03) and both variables significantly increased from group 1 to group 3 (p < 0,001). Perioperative complications remained low throughout the caseload with similar significant 3-month functional improvements between all groups. CONCLUSION: This is the first study to evaluate ThuFLEP learning curve for a single surgeon inexperienced in laser EEP with limited mentoring. Under these real-world conditions, nearly 60 cases were needed to complete the learning curve with a complications rate remaining low throughout the training process.


Asunto(s)
Terapia por Láser , Curva de Aprendizaje , Prostatectomía , Hiperplasia Prostática , Tulio , Humanos , Masculino , Estudios Retrospectivos , Hiperplasia Prostática/cirugía , Anciano , Terapia por Láser/métodos , Tulio/uso terapéutico , Persona de Mediana Edad , Prostatectomía/métodos , Prostatectomía/educación , Competencia Clínica , Láseres de Estado Sólido/uso terapéutico
7.
World J Urol ; 42(1): 467, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39093491

RESUMEN

PURPOSE: The solid-state Thulium laser (Tm: YAG) is a novel alternative to the widely used Holmium laser for endoscopic enucleation of the prostate (EEP) due to its relatively high peak power. The aim of this study was to examine the efficacy and safety of a new pulsed Tm: YAG laser in its first application in humans. METHODS: Data were retrospectively collected for the first 103 patients who underwent EEP with a new pulsed solid-state Tm: YAG laser (Thulio®, Dornier MedTech Systems GmbH, Weßling, Germany). Peri- and postoperative data were assessed. Procedure-specific complications were graded using Clavien-Dindo Classifications (CDC). Patients were interviewed 15 months after the surgery to evaluate functional and long-term outcomes. Statistical analysis was performed with Statistical Package for the Social Sciences (SPSS®). RESULTS: The mean preoperative prostate volume was 105.6 ± 55.0 ml. Median enucleation speed was 4.1 g per minute (range 1.1-9.7). Short-term postoperative complications occurred in 21 patients (20.4%), but no high-grade complications (CDC ≥ IV) were observed. Five patients suffered gross haematuria and required reintervention (CDC IIIb; 4.9%). After 15 months, 76 patients (73.8%) participated in the follow-up interview, where seven patients (9.2%) reported complications, including two reinterventions for urethral strictures (CDC IIIb; 2.6%). Most patients reported an improvement in continence (54.0%) and urine stream (93.4%), but no difference in erectile function (81.6%). No persistent dysuria was reported. Patient satisfaction with the surgery results was very high (96.1%). CONCLUSION: Endoscopic enucleation of the prostate with the new pulsed solid-state Tm: YAG laser is a safe and effective option for surgical BPH treatment. TRIAL REGISTRATION: German Clinical Trials Register number: DRKS00031676. Registration date: 10 May 2023, retrospectively registered.


Asunto(s)
Láseres de Estado Sólido , Hiperplasia Prostática , Tulio , Humanos , Masculino , Láseres de Estado Sólido/uso terapéutico , Anciano , Estudios Retrospectivos , Hiperplasia Prostática/cirugía , Persona de Mediana Edad , Tulio/uso terapéutico , Prostatectomía/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Endoscopía/métodos , Complicaciones Posoperatorias/epidemiología , Terapia por Láser/métodos
8.
World J Urol ; 42(1): 374, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38871959

RESUMEN

PURPOSE: To compare the efficacy and safety of Holmium laser enucleation of the prostate (HoLEP), Thulium laser enucleation of prostate (ThuLEP) and Thulium fibre laser enucleation of prostate (ThuFLEP) by performing propensity score matched analysis (PSM). METHODS: We retrospectively analysed the patients who underwent HoLEP (Group 1, n = 696), ThuLEP (Group 2, n = 146) and ThuFLEP (Group 3, n = 193) surgery because of benign prostatic obstruction (BPO). A 1:1:1 HoLEP: ThuLEP: ThuFLEP group matching was performed using PSM analysis. Perioperative, postoperative functional outcomes and complications were analysed and compared. RESULTS: We observed significant improvement in functional parameters regarding IPSS, Qmax, PVR and quality of life in all groups compared to baseline values at the 1st, 6th and 12th postoperative months. There was no significant difference between different laser types in terms of urge (UUI) and stress urinary incontinence (SUI) at 1st postoperative month. In all three groups, no patient had postoperative SUI or UUI at 6th and 12th postoperative months. In addition, no significant difference was observed between laser types in terms of postoperative complications. CONCLUSION: HoLEP, ThuLEP and ThuFLEP are safe and effective LEP methods with improvement in functional parameters and low complication rates. Similar results in terms of functional outcomes and complications clearly show that these surgeries are alternatives to each other for the patients with BPO. Experts' opinions, practices and enucleation techniques should also be taken into consideration when choosing a laser for BPO surgery.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Puntaje de Propensión , Prostatectomía , Hiperplasia Prostática , Tulio , Humanos , Masculino , Hiperplasia Prostática/cirugía , Hiperplasia Prostática/complicaciones , Estudios Retrospectivos , Láseres de Estado Sólido/uso terapéutico , Anciano , Tulio/uso terapéutico , Terapia por Láser/métodos , Persona de Mediana Edad , Prostatectomía/métodos , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Calidad de Vida
9.
World J Urol ; 42(1): 265, 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38676756

RESUMEN

INTRODUCTION AND OBJECTIVES: To compare the perioperative and functional outcomes of low-power and high-power thulium:YAG VapoEnucleation (ThuVEP) of the prostate for the treatment of large-volume benign prostatic hyperplasia (BPH) (> 80 ml). PATIENTS AND METHODS: A prospective analysis of 80 patients with symptomatic BPO and prostatic enlargement (more than 80 ml) was conducted. They were divided randomly into two groups (40 patients in each group). One group was treated with low-power ThuVEP, and the other group was treated with high-power ThuVEP. All patients were assessed preoperatively and early postoperatively, and 12-month follow-up data were analyzed. The complications were noted and classified according to the modified Clavien classification system. RESULTS: The mean age at surgery was 68 (± 6.1) years, and the mean prostate volume was 112 (± 20.1) cc, and there were no differences between the groups (p = 0.457). The mean operative time was 88.4 ± 11.79 min for group A and 93.4 ± 16.34 min for group B, while the mean enucleation time was 59.68 ± 7.24 min for group A and 63.13 ± 10.75 min for group B. There were no significant differences between the groups regarding catheterization time and postoperative stay. The quality of life (QoL), International Prostate Symptom Score (IPSS), maximum urinary flow rate (Qmax), postvoiding residual urine (PVR), and prostate volume improved significantly after treatment and were not significantly different between those treated with the different energies. The incidence of complications was low and did not differ between both the groups. CONCLUSION: Low-power ThuVEP is feasible, safe, and effective with comparable results with high-power ThuVEP in the treatment of BPO.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Hiperplasia Prostática , Tulio , Humanos , Hiperplasia Prostática/cirugía , Hiperplasia Prostática/patología , Masculino , Anciano , Tulio/uso terapéutico , Estudios Prospectivos , Láseres de Estado Sólido/uso terapéutico , Terapia por Láser/métodos , Persona de Mediana Edad , Tamaño de los Órganos , Prostatectomía/métodos , Resultado del Tratamiento , Próstata/patología , Próstata/cirugía
10.
World J Urol ; 42(1): 487, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39158747

RESUMEN

OBJECTIVE: To evaluate the stone ablation rate and direct thermal damage from thulium fiber laser (TFL) lithotripsy using continuous (C) and burst (B) lasing techniques on an in vitro ureteral model. METHODS: The TFL Drive (Coloplast, Humlebaek, Denmark) was used in an in vitro saline-submerged ureteral model. Ten participants, including five junior and five experienced urologists, conducted the experimental setup with 7 different settings comparing two lasing techniques: steady-state lasing (0.5 J/10 Hz = 5W for 300 s and 0.5 J/20 Hz = 10W for 150 s) and burst, intermittent 5 s on/off lasing (0.5 J/20 Hz, 0.5 J/30 Hz, 0.5 J/60 Hz, 0.1 J/200 Hz, and 0.05 J/400 Hz) with a target cumulative energy of 1500 J using cubic 125 mm3 phantom BegoStonesTM. Ureteral damage was graded 1-3 based on the severity of burns and holes observed on the surface of the ureteral model. RESULTS: The were no significant differences in stone ablation mass neither between C and B lasing techniques, nor between expertise levels. At C lasing technique had only mild ureteral lesions with no significant differences between expertise levels (p: 0.97) or laser settings (p: 0.71). At B lasing technique, different types of thermal lesions were found with no expertise (p: 0.11) or setting (p: 0.83) differences. However, B laser setting had higher grade direct thermal lesions than C (p: 0.048). CONCLUSION: Regarding efficacy, C and B lasing techniques achieve comparable stone ablation rates. Safety-wise, B lasing mode showed higher grade of direct thermal lesions. These results should be further investigated to verify which of the lasing mode is the safest in vivo. Until then and unless proven otherwise, a C mode with low frequency should be recommended to avoid ureteral wall lesions.


Asunto(s)
Litotripsia por Láser , Tulio , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Humanos , Uréter/cirugía , Cálculos Ureterales/cirugía , Técnicas In Vitro , Láseres de Estado Sólido/uso terapéutico
11.
World J Urol ; 42(1): 33, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38217743

RESUMEN

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Asunto(s)
Aluminio , Láseres de Estado Sólido , Litotripsia por Láser , Urolitiasis , Itrio , Humanos , Tulio , Urolitiasis/cirugía , Litotripsia por Láser/métodos , Láseres de Estado Sólido/uso terapéutico , Tecnología , Holmio
12.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38478094

RESUMEN

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Litotricia , Humanos , Tulio/uso terapéutico , Litotripsia por Láser/métodos , Cálculos Renales/cirugía
13.
World J Urol ; 42(1): 431, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39037668

RESUMEN

PURPOSE: This study compares the peri-operative and functional outcomes of three distinct surgical techniques in Thulium Laser Enucleation of the Prostate (ThuLEP) for benign prostatic hyperplasia (BPH). The main aim is to assess whether the En-bloc, Three-lobe, and Two-lobe techniques have differential effects on surgical efficacy and patient outcomes. METHODS: A retrospective analysis was conducted on patients undergoing ThuLEP for BPH between January 2019 and January 2024 at two tertiary centers. Propensity score matching was utilized to balance baseline characteristics among patients undergoing the different techniques. Surgical parameters, including operative time, enucleation time, morcellation time, energy consumption, and postoperative outcomes, were compared among the groups. RESULTS: Following propensity score matching, 213 patients were included in the analysis. Intraoperative analysis revealed significantly shorter enucleation, laser enucleation, morcellation and operative times and total energy delivered in the En-bloc and Two-lobe groups compared to the Three-lobe group. No significant differences were observed among the groups in terms of intraoperative and postoperative complications. There were no significant differences in functional outcomes at the 3-month follow-up among the groups. CONCLUSION: The findings of this study suggest that while the En-bloc and Two-lobe techniques may offer efficiency benefits and could be considered safe alternatives in ThuLEP procedures, the reduction in laser enucleation time and energy delivered did not necessarily translate into improvements in post operative storage symptoms or other functional outcomes for the patients. Surgeon preference and proficiency may play a crucial role in selecting the most suitable technique for individual patients. Future research should focus on larger-scale prospective studies to further validate these findings and explore potential factors influencing surgical outcomes.


Asunto(s)
Puntaje de Propensión , Hiperplasia Prostática , Humanos , Hiperplasia Prostática/cirugía , Masculino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Tulio/uso terapéutico , Terapia por Láser/métodos , Láseres de Estado Sólido/uso terapéutico , Prostatectomía/métodos , Resección Transuretral de la Próstata/métodos , Tempo Operativo
14.
World J Urol ; 42(1): 57, 2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38280001

RESUMEN

INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Litotripsia por Láser , Nefrolitiasis , Cálculos Urinarios , Humanos , Litotripsia por Láser/métodos , Tulio , Cistina , Cálculos Urinarios/cirugía , Láseres de Estado Sólido/uso terapéutico , Holmio
15.
World J Urol ; 42(1): 246, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38643250

RESUMEN

PURPOSE: To assess the learning curve of Thulium laser enucleation of the prostate (ThuLEP) of a single surgeon. METHODS: Hundred patients suffering from benign prostatic hyperplasia were treated by the same surgeon. In all cases, a well-trained urologist was present in the operating room. Patients urinary function was assessed preoperatively using the International Prostate Symptoms Score (IPSS), maximum flow rate and Post-Void Residual volume. Preoperative prostate volume was recorded. Enucleation and morcellation efficiency and complication rate were evaluated. Patients were divided into 5 cohorts of 20 consecutive cases to assess changes in outcomes through time. RESULTS: Mean age of patients was 73.1 years (SD 17.5) and mean prostate volume was 89.7 ml (SD 55.1). Overall, mean enucleation and morcellation efficiency were 1.7 (SD 2.9) and 5.1 (SD 2.7) g/min. A statistically significant increase in enucleation efficiency was observed when comparing cohort 1 vs 2 (0.9 vs 1.3 g/min, p = 0.03) and cohort 2 vs 3 (1.3 vs 1.7 g/min, p = 0.02). A statistically significant increase in morcellation efficiency was observed when comparing cohort 1 vs 2 (2.8 vs 3.7 g/min, p = 0.02) and cohort 2 vs 3 (3.7 vs 4.9 g/min, p = 0.03). In both cases, no significant differences were observed when comparing the following cohorts. Complication rate showed no significant differences throughout the caseload. CONCLUSIONS: In our single-surgeon experience, we observed a learning curve of nearly 60 cases for the ThuLEP procedure in presence of a well-trained surgeon. Complication rate was low from the beginning of surgical experience.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Hiperplasia Prostática , Masculino , Humanos , Anciano , Próstata/cirugía , Tulio , Curva de Aprendizaje , Resultado del Tratamiento , Terapia por Láser/métodos , Hiperplasia Prostática/cirugía , Láseres de Estado Sólido/uso terapéutico
16.
World J Urol ; 42(1): 49, 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38244076

RESUMEN

PURPOSE: Holmium laser enucleation of the prostate (HoLEP) represents the current standard procedure for size-independent surgical therapy of benign prostatic obstruction (BPO). With advent of the novel laser technology thulium fiber laser (TFL), we hypothesized that the functional outcome of TFL enucleation of the prostate (ThuFLEP) is non-inferior compared to HoLEP. METHODS: From October 2021 to October 2022, 150 patients with BPO were recruited for the prospective randomized trial in accordance with CONSORT. Stratified randomization into the arms ThuFLEP (n = 74) or HoLEP (n = 76) was carried out. The primary endpoint was non-inferior international prostate symptom score (IPSS) and quality of life (QoL) at three months after treatment. Secondary endpoints were rates of complications, peak flow, residual urine and operation times. RESULTS: Preoperative characteristics showed no significant differences. Overall IPSS and QoL improved from 21 to 8 and 4 to 1.5, respectively, after three months of follow-up. No statistically significant differences between ThuFLEP and HoLEP were observed regarding median postoperative IPSS (8.5 vs. 7, p > 0.9), QoL (1 vs. 2, p = 0.6), residual urine (48 vs. 30ml, p = 0.065) and peak flow (19 vs. 17ml/s, p > 0.9). Similarly, safety profile was comparable with no statistically significant differences regarding rate of major complications (5.3 vs. 5.4%, p = 0.5), laser hemostasis time (3 vs. 2min, p = 0.2), use of additive electric coagulation (74 vs. 87%, p = 0.06) or electric coagulation time (8 vs. 8min, p = 0.4). CONCLUSIONS: In this prospective, randomized trial ThuFLEP showed non-inferior results compared to HoLEP in terms of functional outcomes measured by IPSS and QoL as primary endpoint. TRIAL REGISTRATION NUMBER: DRKS00032699 (18.09.2023, retrospectively registered).


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Hiperplasia Prostática , Retención Urinaria , Masculino , Humanos , Próstata/cirugía , Láseres de Estado Sólido/uso terapéutico , Tulio/uso terapéutico , Calidad de Vida , Hiperplasia Prostática/complicaciones , Estudios Prospectivos , Resultado del Tratamiento , Terapia por Láser/métodos , Retención Urinaria/cirugía , Holmio
17.
Curr Urol Rep ; 25(4): 71-78, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38349464

RESUMEN

PURPOSE OF REVIEW: Lasers have had a significant impact on the treatment of benign prostatic hypertrophy. This article attempts to distill the advancements in laser technology for the treatment of benign prostatic hypertrophy (BPH) into key and understandable points to help make this topic more accessible to urologists. RECENT FINDINGS: The holmium:yttrium-aluminum-garnet (YAG) laser, one of the most significant lasers in the field of urology, has recently been improved with pulse modulating technology (Moses™ technology). New thulium:YAG technology allows both pulsed and continuous wave modes. The thulium fiber laser is one of the newer lasers to come to market and has been shown to have effective and safe outcomes. GreenLight™ lasers are predominantly used in photovaporization procedures and have also been studied extensively, although less in recent years. The modern urologist is fortunate to have many high-quality lasers and a wide variety of surgical techniques to choose from when treating BPH. Understanding the basic laser principles and applications will help urologists to select the best treatment options for their patients with BPH.


Asunto(s)
Hiperplasia Prostática , Humanos , Masculino , Hiperplasia Prostática/cirugía , Tulio , Rayos Láser , Tecnología , Urólogos
18.
BMC Urol ; 24(1): 44, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38374098

RESUMEN

OBJECTIVES: To compare the efficacy and safety of thulium fiber laser (TFL) to holmium: YAG (Ho: YAG) laser in ureteroscopic lithotripsy for urolithiasis. METHODS: PubMed, Web of Science, Embase, CENTRAL, SinoMed, CNKI database, VIP and Wanfang Database were systematically searched for all relevant clinical trials until September 2023. References were explored to identify the relevant articles. Meta-analysis was carried out for the retrieved studies using RevMan5.4.1 software, and the risk ratio, mean difference and 95% confidence interval were expressed. Statistical significance was set at p < 0.05. The main outcomes of this meta-analysis were stone-free rate (SFR), perioperative outcomes and intraoperative or postoperative complications. RESULTS: Thirteen studies, including 1394 patients, were included. According to the results of pooled analysis, TFL was associated with significantly higher stone-free rate (SFR) [0.52, 95% CI (0.32, 0.85), P = 0.009], shorter operation time [-5.47, 95% CI (-8.86, -2.08), P = 0.002], and less stone migration [0.17, 95% CI (0.06, 0.50), P = 0.001]. However, there was no significant difference in terms of the laser time, duration of hospital stay, drop of hemoglobin level, total energy, postoperative ureteral stenting, the incidence of intraoperative complications or postoperative complications between TFL and Ho: YAGs. CONCLUSION: The findings of this study demonstrated several advantages of TFL in terms of higher SFR, shorter operative time and less stone migration. TRIAL REGISTRATION: The protocol of this systematic review was listed in PROSPERO ( www.crd.york.ac.uk/PROSPERO ) (Protocol number: CRD42022362550).


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Tulio , Ureteroscopía , Humanos , Ureteroscopía/métodos , Láseres de Estado Sólido/uso terapéutico , Litotripsia por Láser/métodos , Resultado del Tratamiento , Urolitiasis/cirugía , Urolitiasis/terapia
19.
Lasers Surg Med ; 56(6): 592-596, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38890781

RESUMEN

BACKGROUND: Skin rejuvenation is a widely sought-after goal, prompting advancements in laser technology for noninvasive and effective treatments. Ablative lasers, in particular, have evolved to address diverse skin concerns, with fractional ablative lasers offering better-tolerated outcomes. The introduction of a novel ablative Thulium pulsed laser, based on Thulium-doped Yttrium aluminum Perovskite (Tm:YAP) crystal, delivers precise and controlled skin rejuvenation by allowing customization of ablative microcolumns. METHODS: A pilot in vivo study was conducted on the abdominal skin of a live female pig. Using the Laser Team Medical (LTM) prototype laser, treatments were administered with varying coagulation settings (minimal and maximum) and energies (32, 80, 120, and 160 mJ per microcolumn). Biopsies were harvested, fixed, and stained for subsequent analysis. The penetration depth and width of the microcolumns were evaluated. RESULTS: Low coagulation settings produced ablative microcolumns with thermal affected zones of 160 µm width, while high coagulation settings resulted in wider zones of 400-530 µm. The ablation cavities' width was estimated to be less than 100 µm in both settings. The novel 1940 nm pulsed laser demonstrated superior microcolumn properties, offering potential advantages such as shorter downtime and increased efficacy compared to existing fractional ablative lasers. CONCLUSION: This study presents encouraging preliminary results regarding the efficacy and safety of the first ablative 1940 nm pulsed laser. The results show ablative microcolumns thinner than the counterpart devices, showing the device safety and potential higher efficacy along with short downtime. The LTM novel ablative 1940 nm pulsed laser holds immense potential for enhancing skin rejuvenation treatments due to its superior microcolumns properties. The versatility of this laser can open new treatment procedures and may extend to different areas of dermatology.


Asunto(s)
Láseres de Estado Sólido , Rejuvenecimiento , Animales , Femenino , Porcinos , Láseres de Estado Sólido/uso terapéutico , Proyectos Piloto , Envejecimiento de la Piel/efectos de la radiación , Terapia por Láser/métodos , Terapia por Láser/instrumentación , Piel/efectos de la radiación , Tulio
20.
Lasers Med Sci ; 39(1): 190, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39042320

RESUMEN

This meta-analysis evaluates the efficacy and safety of greenlight (PVP) and thulium laser vaporization (ThuVAP) in Benign Prostatic Hyperplasia (BPH) treatment. A systematic literature search was conducted in databases including PubMed, Cochrane Library, EMBASE, CNKI, Wangfang, and VIP in November 2023. Following the PRISMA guidelines, a systematic review and meta-analysis of the primary outcomes of interest were performed. The review was prospectively registered on PROSPERO under the registration number CRD42023491316. A total of 13 studies were included. The results of the meta-analysis showed that compared to PVP, ThuVAP had a shorter operation time (MD: 8.56, 95% CI: 4.10 ~ 13.03, p = 0.0002), and higher postoperative transfusion (OR:0.26, 95% CI: 0.10 ~ 0.64, p = 0.004). However, no significant differences were observed between the two groups in terms of length of stay (MD: -0.32, 95% CI: -0.78 ~ 0.14, p = 0.17), catherization time (MD: 0.03, 95% CI: -0.13 ~ 0.19, p = 0.73), international prostate symptom score improvement (MD: 0.23, 95% CI: -0.36 ~ 0.81, p = 0.45), quality of life improvement (MD: 0.04, 95% CI: -0.04 ~ 0.12, p = 0.29), maximum urinary flow rate improvement (MD: -0.59, 95% CI: -1.42 ~ 0.24, p = 0.16), postvoid residual urine volume improvement (MD: 1.04, 95% CI: -6.63 ~ 8.71, p = 0.79), overall postoperative complications (OR:1.15, 95% CI: 0.65 ~ 2.03, p = 0.63), postoperative bleeding (OR:1.18, 95%  CI: 0.67 ~ 2.07, p = 0.56), re-peration (OR:0.55, 95% CI: 0.16 ~ 1.95, p = 0.35), urethral stricture (OR:0.90, 95% CI: 0.46 ~ 1.75, p = 0.75), and urinary incontinence (OR:1.07, 95% CI: 0.64 ~ 1.78, p = 0.80). The results of subgroup analysis showed that the results of comparing thulium vaporesection or vapoenucleation with PVP were consistent with the results of the pooled analysis. Both greenlight and thulium laser vaporization are effective and safe, with comparable surgical and functional outcomes. The choice between these methods should be based on patient-specific factors.


Asunto(s)
Terapia por Láser , Hiperplasia Prostática , Tulio , Hiperplasia Prostática/cirugía , Humanos , Masculino , Terapia por Láser/métodos , Terapia por Láser/efectos adversos , Resultado del Tratamiento , Tempo Operativo , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Calidad de Vida , Tiempo de Internación/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA