Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331397

RESUMO

The shortage of specific glycan recognition reagents has proven a significant hurdle in the development of assays to detect altered glycoforms associated with cancer. Here, a carbohydrate-binding aptamer originally selected against the glycan moiety of prostate-specific antigen (PSA) is used as a lectin-mimicking reagent. As a first proof-of-principle, this aptamer has been applied to develop a sandwich-type electrochemical biosensor for the detection of the serum amyloid P (SAP) component, a glycosylated protein whose increased sialylation has been associated with pancreatic cancer. The assay combines a specific antibody for this potential tumor biomarker and the aptamer as capture and detection receptors, respectively. Two oriented antibody immobilization approaches, protein A-based and boronic ester-based attachment to self-assembled monolayers built onto gold surfaces, were comparatively evaluated, the latter being able to circumvent the unwanted interaction between the aptamer and the glycans on the electrode-attached antibody. The resulting biosensing platform allows the detection of the SAP glycoprotein at levels of nanograms per milliliter with a reproducibility value lower than 20%, both in aqueous buffer and in serum. This work represents a proof-of-concept of a promiscuous ligand of proteins with high levels of sialylated glycans typically produced by cancer cells.

2.
Anal Bioanal Chem ; 416(9): 2089-2095, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38093115

RESUMO

Wearable sensors would revolutionize healthcare and personalized medicine by providing individuals with continuous and real-time data about their bodies and environments. Their integration into everyday life has the potential to enhance well-being, improve healthcare outcomes, and offer new opportunities for research. Capacitive sensors technology has great potential to enrich wearable devices, extending their use to more accurate physiological indicators. On the basis of capacitive sensors developed so far to monitor physical parameters, and taking into account the advances in capacitive biosensors, this work discusses the benefits of this type of transduction to design wearables for the monitoring of biomolecules. Moreover, it provides insights into the challenges that must be overcome to take advantage of capacitive transduction in wearable sensors for health.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Técnicas Biossensoriais/métodos , Análise Espectral
3.
Brain Inj ; : 1-12, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39267361

RESUMO

OBJECTIVE: To assess the effectiveness of a psychoeducational intervention program (PIP) compared to standard attention in reducing caregiver burden after the intervention (at 4 months) and at follow-up (at 8 months). METHODS: A multicenter, evaluator-blind, randomized controlled trial. The experimental group received a PIP intervention consisting of 10 weekly group sessions, while the control group received standard attention. The primary outcome was measured as the change scores from baseline on the caregiver's burden (ZBI). The secondary outcomes evaluated included caregiver mental health (GHQ-28), anxiety (STAI), and depression (CES-D). Trial registration: ISRCTN16513116. RESULTS: The sample comprised 76 informal caregivers (41 allocated in the intervention condition and 35 in the control). The caregiver's burden (ZBI) did not show significant differences between groups at 4 months or 8 months. There were favorable and significant changes in the caregiver's mental health (GHQ) and depression (CES-D) at 4 months in the PIP group. There were no significant differences between groups in anxiety during the trial. CONCLUSIONS: The PIP intervention group reported positive effects on general mental health and depression after the intervention but not at follow-up. We need more studies which interventions follow expert recommendations and can sustain positive results over time.

4.
Gastroenterol Hepatol ; 47(4): 319-326, 2024 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37285934

RESUMO

AIMS: The World Endoscopy Organization (WEO) recommends that endoscopy units implement a process to identify postcolonoscopy colorectal cancer (PCCRC). The aims of this study were to assess the 3-year PCCRC rate and to perform root-cause analyses and categorization in accordance with the WEO recommendations. PATIENTS AND METHODS: Cases of colorectal cancers (CRCs) in a tertiary care center were retrospectively included from January 2018 to December 2019. The 3-year and 4-year PCCRC rates were calculated. A root-cause analysis and categorization of PCCRCs (interval and type A, B, C noninterval PCCRCs) were performed. The level of agreement between two expert endoscopists was assessed. RESULTS: A total of 530 cases of CRC were included. A total of 33 were deemed PCCRCs (age 75.8±9.5 years; 51.5% women). The 3-year and 4-year PCCRC rates were 3.4% and 4.7%, respectively. The level of agreement between the two endoscopists was acceptable either for the root-cause analysis (k=0.958) or for the categorization (k=0.76). The most plausible explanations of the PCCRCs were 8 "likely new PCCRCs", 1 (4%) "detected, not resected", 3 (12%) "detected, incomplete resection", 8 (32%) "missed lesion, inadequate examination", and 13 (52%) "missed lesion, adequate examination". Most PCCRCs were deemed noninterval Type C PCCRCs (N=17, 51.5%). CONCLUSION: WEO recommendations for root-cause analysis and categorization are useful to detect areas for improvement. Most PCCRCs were avoidable and were likely due to missed lesions during an otherwise adequate examination.


Assuntos
Colonoscopia , Neoplasias Colorretais , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/etiologia , Estudos Retrospectivos , Prevalência , Fatores de Risco , Fatores de Tempo , Detecção Precoce de Câncer
5.
Anal Bioanal Chem ; 415(29-30): 7035-7045, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37794245

RESUMO

A major societal challenge is the development of the necessary tools for early diagnosis of diseases such as cancer and sepsis. Consequently, there is a concerted push to develop low-cost and non-invasive methods of analysis with high sensitivity and selectivity. A notable trend is the development of highly sensitive methods that are not only amenable for point-of-care (POC) testing, but also for wearable devices allowing continuous monitoring of biomarkers. In this context, a non-invasive test for the detection of a promising biomarker, the protein Interleukin-6 (IL-6), could represent a significant advance in the clinical management of cancer, in monitoring the chemotherapy response, or for prompt diagnosis of sepsis. This work reports a capacitive electrochemical impedance spectroscopy sensing platform tailored towards POC detection and treatment monitoring in human serum. The specific recognition of IL-6 was achieved employing gold surfaces modified with an anti-IL6 nanobody (anti-IL-6 VHH) or a specific IL-6 aptamer. In the first system, the anti-IL-6 VHH was covalently attached to the gold surface using a binary self-assembled-monolayer (SAM) of 6-mercapto-1-hexanol (MCH) and 11-mercaptoundecanoic acid. In the second system, the aptamer was chemisorbed onto the surface in a mixed SAM layer with MCH. The analytical performance for each label-free sensor was evaluated in buffer and 10% human serum samples and then compared. The results of this work were generated using a low-cost, thin film eight-channel gold sensor array produced on a flexible substrate providing useful information on the future design of POC and wearable impedance biomarker detection platforms.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Neoplasias , Sepse , Humanos , Técnicas Biossensoriais/métodos , Interleucina-6 , Aptâmeros de Nucleotídeos/química , Ouro/química , Biomarcadores , Eletrodos , Técnicas Eletroquímicas/métodos
6.
Anal Bioanal Chem ; 415(11): 2045-2057, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36344668

RESUMO

The glycosylation status of proteins is increasingly used as biomarker to improve the reliability in the diagnosis and prognosis of diseases as relevant as cancer. This feeds the need for tools that allow its simple and reliable analysis and are compatible with applicability in the clinic. With this objective in mind, this work reports the first bioelectronic immunoplatforms described to date for the determination of glycosylated haptoglobin (Hp) and the simultaneous determination of total and glycosylated Hp. The bioelectronic immunoplatform is based on the implementation of non-competitive bioassays using two different antibodies or an antibody and a lectin on the surface of commercial magnetic microcarriers. The resulting bioconjugates are labeled with the horseradish peroxidase (HRP) enzyme, and after their magnetic capture on disposable electroplatforms, the amperometric transduction using the H2O2/hydroquinone (HQ) system allows the single or multiple detection. The developed immunoplatform achieves limits of detection (LODs) of 0.07 and 0.46 ng mL-1 for total and glycosylated Hp in buffer solution, respectively. The immunoplatform allows accurate determination using simple and relatively short protocols (approx. 75 min) of total and glycosylated Hp in the secretomes of in vitro-cultured colorectal cancer (CRC) cells with different metastatic potentials, which is not feasible, due to lack of sensitivity, by means of some commercial ELISA kits and Western blot methodology.


Assuntos
Técnicas Biossensoriais , Neoplasias , Humanos , Haptoglobinas , Peróxido de Hidrogênio , Reprodutibilidade dos Testes , Ensaio de Imunoadsorção Enzimática , Anticorpos , Técnicas Biossensoriais/métodos
7.
Gastroenterol Hepatol ; 46(4): 255-260, 2023 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35609791

RESUMO

Effective vaccines against the SARS-CoV-2 are already available and offer a promising action to control the COVID-19 pandemic. IBD patients on biological agents accept the vaccine as well as an additional dose if recommended. BACKGROUND: Vaccination against COVID-19 prevents its severe forms and associated mortality and offers a promising action to control this pandemic. In September 2021, an additional dose of vaccine was approved in patients with immunosuppression including IBD patients on biologic agents. We evaluated the vaccination rate and additional dose willingness in this group of at risk patients. METHODS: A single-center, cross-sectional study was performed among IBD patients on biologic agents and eligible for an additional dose of the COVID-19 vaccine. IBD clinical characteristics and type of vaccine and date of administration were checked in medical records. Acceptance was evaluated after telephone or face-to-face surveys in IBD patients. RESULTS: Out of a total of 344 patients, 269 patients (46.1% male; mean age 47±16 years; Crohn's disease 73.6%) were included. Only 15 (5.6%) patients refused the COVID-19 vaccine mainly (40%) for conviction (COVID-19 pandemic denial). 33.3% would re-consider after discussing with their doctor and/or receiving information on the adverse effects of the vaccine. Previous to the additional dose, the COVID-19 vaccination was present in 94.4% of patients (n=254). Adverse effects occurred in 53.9% of the cases, mainly pain in the arm (40%). Up to 94.1% of the patients agreed to an additional dose and 79.4% had already received the additional dose at the final time of the assessment. CONCLUSIONS: IBD patients on biological agents accept the vaccine as well as an additional dose if recommended. Physicians in charge of IBD units should provide information and confidence in the use of the vaccine in these IBD patients.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Doenças Inflamatórias Intestinais , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Biológicos , Terapia Biológica/efeitos adversos , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Estudos Transversais , Doenças Inflamatórias Intestinais/tratamento farmacológico , Pandemias , SARS-CoV-2 , Vacinação
8.
Anal Bioanal Chem ; 414(1): 147-165, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34091712

RESUMO

The role of the extracellular matrix (ECM) remodeling in tumorigenesis and metastasis is becoming increasingly clear. Cancer development requires that tumor cells recruit a tumor microenvironment permissive for further tumor growth. This is a dynamic process that takes place by a cross-talk between tumor cells and ECM. As a consequence, molecules derived from the ECM changes associated to cancer are released into the bloodstream, representing potential biomarkers of tumor development. This article highlights the importance of developing and improving bioanalytical methods for the detection of ECM remodeling-derived components, as a step forward to translate the basic knowledge about cancer progression into the clinical practice.


Assuntos
Biomarcadores Tumorais , Proteínas da Matriz Extracelular/química , Neoplasias/diagnóstico , Proteínas da Matriz Extracelular/metabolismo , Humanos , Conformação Proteica
9.
Sensors (Basel) ; 20(19)2020 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-32993106

RESUMO

A personal glucose meter (PGM)-based method for quantitative detection of a urinary nucleic acid biomarker in prostate cancer screening, the so-called PCA3, is reported herein. A sandwich-type genoassay is conducted on magnetic beads to collect the target from the sample by specific hybridization, making the assay appropriate for PCA3 detection in biological fluids. The success of the method hinges on the use of alkaline phosphatase (ALP) to link the amount of nucleic acid biomarker to the generation of glucose. In particular, specifically attached ALP molecules hydrolyze D-glucose-1-phosphate into D-glucose, thus enabling the amplification of the recorded signal on the personal glucose meter. The developed genoassay exhibits good sensitivity (3.3 ± 0.2 mg glucose dL-1 pM-1) for PCA3, with a dynamic range of 5 to 100 pM and a quantification limit of 5 pM. Likewise, it facilitates point-of-care testing of nucleic acid biomarkers by using off-the-shelf PGM instead of complex instrumentation involved in traditional laboratory-based tests.


Assuntos
Biomarcadores/urina , Técnicas Biossensoriais , Detecção Precoce de Câncer/instrumentação , Ácidos Nucleicos/urina , Antígeno Prostático Específico/urina , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/diagnóstico
10.
Anal Bioanal Chem ; 411(19): 4265-4275, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30683966

RESUMO

Despite having been underappreciated in favor of their protein-coding counterparts for a long time, long noncoding RNAs (lncRNAs) have emerged as functional molecules, which defy the central dogma of molecular biology, with clear implications in cancer. Altered expression levels of some of these large transcripts in human body fluids have been related to different cancer conditions that turns them into potential noninvasive cancer biomarkers. In this review, a brief discussion about the importance and current challenges in the determination of lncRNAs associated to cancer is provided. Different electrochemical nucleic acid-based strategies for lncRNAs detection are critically described. Future perspectives and remaining challenges for the practical implementation of these methodologies in clinical medicine are also discussed.


Assuntos
Detecção Precoce de Câncer , Genômica , RNA Longo não Codificante/genética , Humanos
11.
Anal Bioanal Chem ; 410(8): 2059-2065, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29353432

RESUMO

Advances in proteomics have fueled the search for novel cancer biomarkers with higher selectivity. Differential expression of low abundant proteins has been the usual way of finding those biomarkers. The existence of a selective receptor for each biomarker is compulsory for their use in diagnostic/prognostic assays. Antibodies are the receptors of choice in most cases although aptamers are becoming familiar because of their facile and reproducible synthesis, chemical stability as well as comparable affinity and selectivity. In recent years, it has been reported that the pattern of post-translational modifications, altered under neoplastic disease, is a better predictive biomarker than the total protein level. Among others, abnormal glycosylation is attracting great attention. Lectins and antibodies are being used for identification and detection of the carbohydrate moiety with low level of discrimination among various glycoproteins. Such level of selectivity is critical to bring next-generation biomarkers to the clinic. Aptamers that can be rationally tailored for a certain molecule domain can become the golden receptor to specifically detect aberrant glycosylation at each protein or even at each glycosylation site, providing new diagnostic tools for early detection of cancer. Graphical abstract Aptamers may specifically differentiate normal from aberrant glycoproteins.


Assuntos
Técnicas Biossensoriais/métodos , Neoplasias/diagnóstico , Processamento de Proteína Pós-Traducional , Animais , Aptâmeros de Nucleotídeos/análise , Aptâmeros de Nucleotídeos/metabolismo , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/metabolismo , Glicosilação , Humanos , Modelos Moleculares , Neoplasias/metabolismo , Polissacarídeos/análise , Polissacarídeos/metabolismo , Técnica de Seleção de Aptâmeros/métodos
12.
Anal Bioanal Chem ; 410(3): 679-693, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28932883

RESUMO

Highly sensitive testing of nucleic acids is essential to improve the detection of pathogens, which pose a major threat for public health worldwide. Currently available molecular assays, mainly based on PCR, have a limited utility in point-of-need control or resource-limited settings. Consequently, there is a strong interest in developing cost-effective, robust, and portable platforms for early detection of these harmful microorganisms. Since its description in 2004, isothermal helicase-dependent amplification (HDA) has been successfully applied in the development of novel molecular-based technologies for rapid, sensitive, and selective detection of viruses and bacteria. In this review, we highlight relevant analytical systems using this simple nucleic acid amplification methodology that takes place at a constant temperature and that is readily compatible with microfluidic technologies. Different strategies for monitoring HDA amplification products are described. In addition, we present technological advances for integrating sample preparation, HDA amplification, and detection. Future perspectives and challenges toward point-of-need use not only for clinical diagnosis but also in food safety testing and environmental monitoring are also discussed. Graphical Abstract Expanding the analytical toolbox for the detection of DNA sequences specific of pathogens with isothermal helicase dependent amplification (HDA).


Assuntos
DNA Bacteriano/análise , DNA Viral/análise , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Animais , Bactérias/isolamento & purificação , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , DNA Helicases/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Análise de Perigos e Pontos Críticos de Controle/métodos , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Temperatura , Viroses/diagnóstico , Viroses/virologia , Vírus/isolamento & purificação
13.
Molecules ; 23(6)2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29865205

RESUMO

The reaction of para-hydroxybenzyl alcohols with ferrocene in the presence of a catalytic amount of InCl3 provided ferrocenyl phenol derivatives, an interesting class of organometallic compounds with potential applications in medicinal chemistry. This transformation exhibited a reasonable substrate scope delivering the desired products in synthetically useful yields. Evidence of involvement of a para-quinone methide intermediate in this coupling process was also provided. Preliminary biological evaluation demonstrated that some of the ferrocene derivatives available by this methodology exhibit significant cytotoxicity against several cancer cell lines with IC50 values within the range of 1.07⁻4.89 µM.


Assuntos
Compostos Ferrosos/química , Indolquinonas/química , Metalocenos/química , Fenol/química , Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Linhagem Celular Tumoral , Cristalografia por Raios X , Avaliação Pré-Clínica de Medicamentos , Humanos , Concentração Inibidora 50 , Espectroscopia de Prótons por Ressonância Magnética , Espectrometria de Massas por Ionização por Electrospray
14.
Angew Chem Int Ed Engl ; 57(39): 12850-12854, 2018 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-30070419

RESUMO

Herein, we show the feasibility of using deep eutectic solvents as a faster way of selecting aptamers targeting poorly water-soluble species. This unexplored concept is illustrated for gluten proteins. In this way, aptamer-based gluten detection can be performed directly in the extraction media with improved detectability. We envision deep implications for applications not only in food safety control but also in biomedicine.


Assuntos
Aptâmeros de Nucleotídeos/química , Glutens/análise , Técnica de Seleção de Aptâmeros/métodos , Solventes/química , Aptâmeros de Nucleotídeos/metabolismo , Sequência de Bases , Biotinilação , Glutens/metabolismo , Água/química
15.
Crit Rev Food Sci Nutr ; 57(13): 2758-2774, 2017 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-26565945

RESUMO

The main goal of food safety assessment is to provide reliable information on the identity and composition of food and reduce the presence of harmful components. Nowadays, there are many countries where rather than the presence of pathogens, common public concerns are focused on the presence of hidden allergens, fraudulent practices, and genetic modifications in food. Accordingly, food regulations attempt to offer a high level of protection and to guarantee transparent information to the consumers. The availability of analytical methods is essential to comply these requirements. Protein-based strategies are usually employed for this purpose, but present some limitations. Because DNA is a more stable molecule, present in most tissues, and can be amplified, there has been an increasing interest in developing DNA-based approaches (polymerase chain reaction, microarrays, and genosensors). In this regard, electrochemical genosensors may play a major role in fulfilling the needs of food industry, such as reliable, portable, and affordable devices. This work reviews the achievements of this technology applied to allergen detection, species identification, and genetically modified organisms testing. We summarized the legislative framework, current design strategies in sensor development, their analytical characteristics, and future prospects.


Assuntos
Alérgenos/análise , Contaminação de Alimentos/análise , Inocuidade dos Alimentos/métodos , Organismos Geneticamente Modificados , Indústria Alimentícia
16.
Sensors (Basel) ; 17(4)2017 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-28420193

RESUMO

The design of screening methods for the detection of genetically modified organisms (GMOs) in food would improve the efficiency in their control. We report here a PCR amplification method combined with a sequence-specific electrochemical genosensor for the quantification of a DNA sequence characteristic of the 35S promoter derived from the cauliflower mosaic virus (CaMV). Specifically, we employ a genosensor constructed by chemisorption of a thiolated capture probe and p-aminothiophenol gold surfaces to entrap on the sensing layer the unpurified PCR amplicons, together with a signaling probe labeled with fluorescein. The proposed test allows for the determination of a transgene copy number in both hemizygous (maize MON810 trait) and homozygous (soybean GTS40-3-2) transformed plants, and exhibits a limit of quantification of at least 0.25% for both kinds of GMO lines.


Assuntos
Reação em Cadeia da Polimerase em Tempo Real , Biotecnologia , Caulimovirus , Produtos Agrícolas , DNA de Plantas , Técnicas Eletroquímicas , Plantas Geneticamente Modificadas , Zea mays
17.
Anal Bioanal Chem ; 408(30): 8603-8610, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27055885

RESUMO

Methods for the early and sensitive detection of pathogenic bacteria suited to low-resource settings could impact diagnosis and management of diseases. Helicase-dependent isothermal amplification (HDA) is an ideal tool for this purpose, especially when combined with a sequence-specific detection method able to improve the selectivity of the assay. The implementation of this approach requires that its analytical performance is shown to be comparable with the gold standard method, polymerase chain reaction (PCR). In this study, we optimize and compare the asymmetric amplification of an 84-base-long DNA sequence specific for Mycobacterium tuberculosis by PCR and HDA, using an electrochemical genomagnetic assay for hybridization-based detection of the obtained single-stranded amplicons. The results indicate the generalizability of the magnetic platform with electrochemical detection for quantifying amplification products without previous purification. Moreover, we demonstrate that under optimal conditions the same gene can be amplified by either PCR or HDA, allowing the detection of as low as 30 copies of the target gene sequence with acceptable reproducibility. Both assays have been applied to the detection of M. tuberculosis in sputum, urine, and pleural fluid samples with comparable results. Simplicity and isothermal nature of HDA offer great potential for the development of point-of-care devices. Graphical Abstract Comparative evaluation of isothermal helicase-dependent amplification and PCR for electrochemical detection of Mycobacterium tuberculosis.


Assuntos
Bioensaio , DNA Bacteriano/análise , Técnicas Eletroquímicas , Mycobacterium tuberculosis/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico , Tuberculose Pulmonar/urina , DNA Helicases/química , Humanos , Limite de Detecção , Imãs , Mycobacterium tuberculosis/genética , Hibridização de Ácido Nucleico/métodos , Derrame Pleural/microbiologia , Reprodutibilidade dos Testes , Escarro/química , Escarro/microbiologia , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia
18.
Anal Chem ; 87(16): 8547-54, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26198403

RESUMO

Cultivation of genetically modified organisms (GMOs) and their use in food and feed is constantly expanding; thus, the question of informing consumers about their presence in food has proven of significant interest. The development of sensitive, rapid, robust, and reliable methods for the detection of GMOs is crucial for proper food labeling. In response, we have experimentally characterized the helicase-dependent isothermal amplification (HDA) and sequence-specific detection of a transgene from the Cauliflower Mosaic Virus 35S Promoter (CaMV35S), inserted into most transgenic plants. HDA is one of the simplest approaches for DNA amplification, emulating the bacterial replication machinery, and resembling PCR but under isothermal conditions. However, it usually suffers from a lack of selectivity, which is due to the accumulation of spurious amplification products. To improve the selectivity of HDA, which makes the detection of amplification products more reliable, we have developed an electrochemical platform targeting the central sequence of HDA copies of the transgene. A binary monolayer architecture is built onto a thin gold film where, upon the formation of perfect nucleic acid duplexes with the amplification products, these are enzyme-labeled and electrochemically transduced. The resulting combined system increases genosensor detectability up to 10(6)-fold, allowing Yes/No detection of GMOs with a limit of detection of ∼30 copies of the CaMV35S genomic DNA. A set of general utility rules in the design of genosensors for detection of HDA amplicons, which may assist in the development of point-of-care tests, is also included. The method provides a versatile tool for detecting nucleic acids with extremely low abundance not only for food safety control but also in the diagnostics and environmental control areas.


Assuntos
DNA Helicases/metabolismo , DNA Viral/análise , Técnicas Eletroquímicas , Técnicas de Amplificação de Ácido Nucleico/métodos , Plantas Geneticamente Modificadas/genética , Caulimovirus/genética , Primers do DNA/metabolismo , DNA Viral/metabolismo , Limite de Detecção , Hibridização de Ácido Nucleico , Plantas Geneticamente Modificadas/virologia , Regiões Promotoras Genéticas
20.
Anal Bioanal Chem ; 407(12): 3481-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25711991

RESUMO

High selectivity of genosensors is crucial for certain applications such as those involving species with high genetic variability. This is an unresolved problem when dealing with long target sequences that is further complicated when the target contains repetitive sequence domains. As a model for this situation, the problem of detecting gluten in food with identification of the source is studied. In order to discriminate the specific DNA sequence that encodes the wheat prolamin (gliadin) from rye and barley prolamins, the exquisite selectivity of a rationally designed hairpin capture probe is proposed and compared to a nonstructured capture probe. An electrochemical sandwich assay is proposed, involving capture probes chemisorbed on Au surfaces and biotinylated-signaling probes in combination with streptavidin-peroxidase labeling conjugates. As a result, a genosensor with similar sensitivity to that observed with linear probes but with complete specificity against closely related species was achieved. The surface-attached DNA stem-loop yields a device capable of accurately discriminating wheat DNA from rye and barley with a limit of detection of 1 nM.


Assuntos
DNA/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Gliadina/análise , Sondas Moleculares/química , Sequência de Bases , Gliadina/genética , Hordeum/química , Hordeum/genética , Limite de Detecção , Dados de Sequência Molecular , Secale/química , Secale/genética , Sensibilidade e Especificidade , Estreptavidina/química , Triticum/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA