Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(9): 1961-1968, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37449437

RESUMO

INTRODUCTION: Insertable cardiac monitors (ICMs) are commonly used to diagnose cardiac arrhythmias. False detections in the latest ICM systems remain an issue, primarily due to inaccurate R-wave sensing. New discrimination algorithms were developed and tested to reduce false detections of atrial fibrillation (AF), pause, and tachycardia episodes in ICMs. METHODS: Stored electrograms (EGMs) of AF, pause, and tachycardia episodes detected by Abbott Confirm Rx™ ICMs were extracted from the Merlin.net™ Patient Care Network, and manually adjudicated to establish independent training and testing datasets. New discrimination algorithms were developed to reject false episodes due to inaccurate R-wave sensing, P-wave identification, and R-R interval patterns. The performance of these new algorithms was quantified by false positive reduction (FPR) and true positive maintenance (TPM), relative to the existing algorithms. RESULTS: The new AF detection algorithm was trained on 5911 EGMs from 744 devices, resulting in 66.9% FPR and 97.8% TPM. In the testing data set of 1354 EGMs from 119 devices, this algorithm achieved 45.8% FPR and 97.0% TPM. The new pause algorithm was trained on 7178 EGMs from 1490 devices, resulting in 70.9% FPR and 98.7% TPM. In the testing data set of 1442 EGMs from 340 devices, this algorithm achieved 74.4% FPR and 99.3% TPM. The new tachycardia algorithm was trained on 520 EGMs from 204 devices, resulting in 57.0% FPR and 96.6% TPM. In the testing data set of 459 EGMs from 237 devices, this algorithm achieved 57.9% FPR and 96.5% TPM. CONCLUSION: The new algorithms substantially reduced false AF, pause, and tachycardia episodes while maintaining the majority of true arrhythmia episodes detected by the Abbott ICM algorithms that exist today. Implementing these algorithms in the next-generation ICM systems may lead to improved detection accuracy, in-clinic efficiency, and device battery longevity.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Humanos , Eletrocardiografia Ambulatorial/métodos , Fibrilação Atrial/diagnóstico , Algoritmos , Síncope/diagnóstico
2.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493499

RESUMO

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Estudos Retrospectivos , Cardioversão Elétrica/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos
3.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37221927

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Imageamento por Ressonância Magnética , Trombose/diagnóstico por imagem , Cateterismo Cardíaco , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 33(4): 741-750, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35118767

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are essential for ambulatory arrhythmia diagnosis. However, definitive diagnoses still require time-consuming, manual adjudication of electrograms (EGMs). OBJECTIVE: To evaluate the clinical impact of selecting only key EGMs for review. METHODS: Retrospective analyses of randomly selected Abbott Confirm Rx™ devices with ≥90 days of remote transmission history were performed, with each EGM adjudicated as true or false positive (TP, FP). For each device, up to 3 "key EGMs" per arrhythmia type per day were prioritized for review based on ventricular rate and episode duration. The reduction in EGMs and TP days (patient-days with at least one TP EGM), and any diagnostic delay (from the first TP), were calculated versus reviewing all EGMs. RESULTS: In 1000 ICMs over a median duration of 8.1 months, at least one atrial fibrillation (AF), tachycardia, bradycardia, or pause EGM was transmitted by 424, 343, 190, and 325 devices, respectively, with a total of 95 716 EGMs. Approximately 90% of episodes were contributed by 25% of patients. Key EGM selection reduced EGM review burden by 43%, 66%, 77%, and 50% (55% overall), while reducing TP days by 0.8%, 2.1%, 0.2%, and 0.0%, respectively. Despite reviewing fewer EGMs, 99% of devices with a TP EGM were ultimately diagnosed on the same day versus reviewing all EGMs. CONCLUSION: Key EGM selection reduced the EGM review substantially with no delay-to-diagnosis in 99% of patients exhibiting true arrhythmias. Implementing these rules in the Abbott patient care network may accelerate clinical workflow without compromising diagnostic timelines.


Assuntos
Fibrilação Atrial , Diagnóstico Tardio , Fibrilação Atrial/diagnóstico , Bradicardia/diagnóstico , Humanos , Estudos Retrospectivos , Taquicardia/diagnóstico
5.
J Cardiovasc Electrophysiol ; 32(8): 2189-2198, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34164881

RESUMO

INTRODUCTION: The LARIAT epicardial suture snaring device has been fraught with technical challenges and procedural complications. Over time, technique modification and improved operator experience have helped overcome many of these challenges. METHODS AND RESULTS: Studies reporting left atrial appendage epicardial closure over a 12-year period from 2009 to 2020 were evaluated. The primary efficacy outcome evaluated was left atrial appendage closure with residual flow ≤1 mm. Safety outcomes evaluated were periprocedural and long term complications after device placement. Nine studies consisting of 1430 patients were included in this analysis, of which 1386 (97%) underwent successful device placement. The mean age was 69.3 years, with a mean CHADS2 -VASC score of 3.78. Primary efficacy end point was achieved in 95.8% patients immediately after device placement, and in 92.8% patients on long term follow-up. Early procedural complications consisted of pericardial effusion 5.6%, cardiac perforation 2.7%, pericarditis 2.6%, and need for open heart surgery 1.5%. Long term complications consisted of all-cause mortality 2.3%, stroke 1.5%, and left atrial appendage thrombus 2.3%. Reduced complications were noted using micropuncture needles (2.20% vs. 10.14%; p < .0001), a longer duration pericardial drainage, and use of anti-inflammatory medications (1.58% vs. 8.4%). Oral anticoagulation use decreased from 44.7% to 22.9% post device implantation, and to 8.5% on last clinical follow up. CONCLUSIONS: The LARIAT device is effective in epicardial closure of the left atrial appendage. Improvement in device techniques such as use of micropuncture needle, prophylactic colchicine, and maintenance of a pericardial drain have helped improve safety over time.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Suturas , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554620

RESUMO

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Assuntos
Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas , Cardioversão Elétrica , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Tela Subcutânea
7.
J Cardiovasc Electrophysiol ; 32(2): 477-483, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33205561

RESUMO

INTRODUCTION: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing-induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long-term outcomes of PICM in LP and TVP patients. METHODS: The study comprised all pacemaker-dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long-term outcomes after cardiac resynchronization (CRT) were assessed in both groups. RESULTS: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow-up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP (p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. CONCLUSION: Incidence of PICM is significantly lower with LP compared with TVP in pacemaker-dependent patients. Age and TVP as pacing modality were predictors for PICM.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/epidemiologia , Humanos , Incidência , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
8.
J Cardiovasc Electrophysiol ; 31(12): 3277-3285, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33058275

RESUMO

BACKGROUND: The leadless Micra transcatheter-pacing system (Micra-TPS) is implanted via a femoral approach using a 27-French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters. OBJECTIVE: To examine the feasibility and safety of Micra-TPS implantation through an IVC filter. METHODS: This multicenter retrospective study included patients with an IVC filter who underwent a Micra-TPS implantation. Data for clinical and IVC filter characteristics, preprocedure imaging, and procedural interventions were collected. The primary outcome was a successful leadless pacemaker (LP) implantation via a femoral approach in the presence of an IVC filter. Periprocedural and delayed clinical complications were also evaluated. RESULTS: Of the 1528 Micra-TPS implants attempted, 23 patients (1.5%) had IVC filters. The majority (69.6%) of IVC filters were permanent. Six (26.1%) patients underwent preprocedural imaging to assess for filter patency. One patient's filter was retrieved before LP implantation. The primary outcome was achieved in 21 of 22 patients (95.5%) with an existing IVC filter. An occluded IVC precluded LP implantation in one patient. Difficulty advancing the stiff guidewire or the 27-Fr sheath was encountered in five patients. These cases required repositioning of the wire (n = 2), gradual sheath upsizing (n = 2), or balloon dilation of the filter (n = 1). Postprocedure fluoroscopy revealed intact filters in all cases. During a median 6-month follow-up, there were no clinical complications related to the filter or the Micra-TPS. CONCLUSION: This multicenter experience demonstrates the feasibility and safety of Micra-TPS implantation via an IVC filter without acute procedural or delayed clinical complications.


Assuntos
Marca-Passo Artificial , Filtros de Veia Cava , Remoção de Dispositivo , Fluoroscopia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
9.
J Cardiovasc Electrophysiol ; 30(11): 2453-2459, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502324

RESUMO

BACKGROUND: An internal risk stratification algorithm was developed to decrease the risk of major adverse cardiac events (MACEs) during lead extractions (LEs). OBJECTIVE: To report upon the impact of a risk stratification algorithm (RISE [RIsk Stratification prior to lead Extraction] protocol) on outcomes of LEs in a high-volume center. METHODS: A retrospective review of a prospectively maintained LEs database was performed to identify features associated with MACEs. On the basis of the retrospective data, the RISE protocol differentiated LEs procedures into "High" and "Low" risk for occurrence of MACEs. High-risk LEs included dual-coil defibrillator lead (≥3 years), pacemaker and single-coil lead (≥5 years), and any StarFix coronary sinus lead. During the prospective evaluation of the RISE protocol, "High-risk" LEs were performed in an operating room (OR) or hybrid laboratory with the cardiac anesthesiologist, OR nursing team, perfusionist in the room, and a cardiac surgeon on the premises. "Low-risk" LEs were performed in the electrophysiology (EP) laboratory with anesthesia provided by EP nursing team. The preintervention (pre-RISE) and postintervention (post-RISE) group spanned 19 and 40 months and consisted of 449 (632 leads) and 751 patients (1055 leads), respectively. The primary outcome of MACEs in the two groups was compared. RESULTS: Protocol compliance was 100%. The primary outcome of MACEs occurred in 15 patients (3.34%) before and 12 (1.6%) after implementation of the RISE protocol (P = .04). CONCLUSION: RISE identified a low-risk group where minimal resources are needed and allowed for rapid intervention in the high-risk group that reduced the consequences of MACEs.


Assuntos
Protocolos Clínicos , Desfibriladores Implantáveis , Remoção de Dispositivo/efeitos adversos , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/mortalidade , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Desenho de Prótese , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 30(5): 792-799, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30834611

RESUMO

BACKGROUND: Central sleep apnea (CSA) is a breathing disorder caused by the intermittent absence of central respiratory drive. Transvenous phrenic nerve stimulation is a new therapeutic option, recently approved by the FDA , for the treatment of CSA. OBJECTIVE: To describe the technique used to implant the transvenous phrenic nerve stimulation system (the remede System, Respicardia, Inc). METHODS: The remede System is placed in the pectoral region, typically on the right side. A single stimulation lead is placed in either the left pericardiophrenic vein (PPV) or the right brachiocephalic vein (RBC). A sensing lead is placed into the azygous vein to detect respiration. RESULTS: In the remede System Pivotal trial, 147 of 151 (97%) patients were successfully implanted with the system. Sixty-two percent of stimulation leads were placed in the PPV and 35% in the RBC. Mean procedure time was 2.7 ± 0.8 hours and 94% of patients were free from implant-related serious adverse events through 6 months. CONCLUSION: In patients with CSA, transvenous phrenic nerve stimulation is an effective and safe therapy with an implant procedure similar to that of cardiac implantable electronic devices.


Assuntos
Diafragma/inervação , Terapia por Estimulação Elétrica/instrumentação , Neuroestimuladores Implantáveis , Nervo Frênico/fisiopatologia , Implantação de Prótese , Respiração , Apneia do Sono Tipo Central/terapia , Terapia por Estimulação Elétrica/efeitos adversos , Humanos , Duração da Cirurgia , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Apneia do Sono Tipo Central/diagnóstico , Apneia do Sono Tipo Central/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 42(8): 1111-1114, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31231810

RESUMO

BACKGROUND: The perioperative management of anticoagulation with the use of subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: The purpose of this study was to assess whether it is safe to perform S-ICD implantation with uninterrupted warfarin. METHODS: This is a multi-center retrospective review of patients undergoing S-ICD implantation between October 1, 2012 and June 30, 2017. Forty-eight patients underwent successful S-ICD implantation during the study period. The most common indication for implantation was primary prevention of sudden cardiac death. In 23 (47.9%) patients, warfarin was continued without any interruption. In 25 (52.1%) patients, warfarin was interrupted prior to implantation. The incidence of clinically significant lateral pocket hematoma was compared in the two groups. RESULTS: The mean international normalized ratio was 2.0 ± 0.4 in the uninterrupted group and 1.4 ± 0.4 for the interrupted group. A total of seven patients developed a hematoma at the lateral pocket. No patient developed a hematoma at the parasternal pockets. Six patients in the uninterrupted group (26.1%) and one patient in the interrupted group (0.04%) developed a significant lateral pocket hematoma (P = .04). The concomitant use of dual antiplatelet therapy did not increase the risk of hematoma. There was no significant difference between HASBLED and CHA2 DS2 VASc scores between the groups. None of the patients with a hematoma developed infection or required hematoma evacuation. CONCLUSIONS: The uninterrupted use of warfarin in the perioperative period of S-ICD implantation is associated with an increased risk of lateral pocket hematoma.


Assuntos
Anticoagulantes/administração & dosagem , Desfibriladores Implantáveis , Hematoma/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Varfarina/administração & dosagem , Adulto , Idoso , Anticoagulantes/efeitos adversos , Feminino , Hematoma/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/induzido quimicamente , Estudos Retrospectivos , Medição de Risco , Varfarina/efeitos adversos
12.
Pacing Clin Electrophysiol ; 42(1): 58-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30414285

RESUMO

BACKGROUND: Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD. METHODS: The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted. RESULTS: There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD. CONCLUSION: Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Falha de Equipamento , Complicações Pós-Operatórias/prevenção & controle , Idoso , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
13.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31702059

RESUMO

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Assuntos
Anestesia/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Anestesia Geral , Anestesia Local , Bradicardia/tratamento farmacológico , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipotensão/tratamento farmacológico , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
14.
Heart Fail Clin ; 15(4): 543-550, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31472889

RESUMO

Hypertension is the most common cardiovascular risk factor and underlies heart failure, coronary artery disease, stroke, and chronic kidney disease. Hypertensive heart disease can manifest as cardiac arrhythmias. Supraventricular and ventricular arrhythmias may occur in the hypertensive patients. Atrial fibrillation and hypertension contribute to an increased risk of stroke. Some antihypertensive drugs predispose to electrolyte abnormalities, which may result in atrial and ventricular arrhythmias. A multipronged strategy involving appropriate screening, aggressive lifestyle modifications, and optimal pharmacotherapy can result in improved blood pressure control and prevent the onset or delay progression of heart failure, coronary artery disease, and cardiac arrhythmias.


Assuntos
Anti-Hipertensivos/farmacologia , Arritmias Cardíacas , Hipertensão , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/prevenção & controle , Humanos , Hipertensão/complicações , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia
15.
J Cardiovasc Electrophysiol ; 29(10): 1460-1466, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29964312

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infections associated with large, mobile vegetation adds to the complexity of lead extraction and is associated with significant patient morbidity and mortality. OBJECTIVE: To show the feasibility of concomitant cardiovascular implantable electronic device extraction and vacuum-assisted removal of lead-related vegetations. METHODS: This is a single-center retrospective case series of consecutive patients with persistent bacteremia, sepsis, or endocarditis despite medical therapy who have vegetations >2 cm and subsequently underwent immediate CIED lead extraction after debulking with vacuum-assisted suction. RESULTS: Eight patients underwent successful removal of 17 leads immediately after debulking of vegetations with vacuum-assisted device suction. Debulking procedure was not successful in 1 patient due to inability to direct the vacuum suction device into proper position. There were no intraprocedure complications related to the vacuum-assisted debulking. One patient required open sternotomy for tear of the coronary sinus ostium related to extraction of a left ventricular pacing electrode. There was no mortality within 30 days of the procedure. CONCLUSIONS: Based upon these clinical results, it is feasible for patients with infected CIED systems that have large right-sided vegetations to undergo vacuum-assisted debulking then immediately followed by percutaneous CIED removal in whom surgical removal is considered high risk.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos de Citorredução/métodos , Remoção de Dispositivo/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/terapia , Adulto , Idoso , Procedimentos Cirúrgicos de Citorredução/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sucção , Resultado do Tratamento , Vácuo , Adulto Jovem
16.
Circ Res ; 118(12): 1918-1929, 2016 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-27126808

RESUMO

RATIONALE: The role of interleukin (IL)-6 in the pathogenesis of cardiac myocyte hypertrophy remains controversial. OBJECTIVE: To conclusively determine whether IL-6 signaling is essential for the development of pressure overload-induced left ventricular (LV) hypertrophy and to elucidate the underlying molecular pathways. METHODS AND RESULTS: Wild-type and IL-6 knockout (IL-6(-/-)) mice underwent sham surgery or transverse aortic constriction (TAC) to induce pressure overload. Serial echocardiograms and terminal hemodynamic studies revealed attenuated LV hypertrophy and superior preservation of LV function in IL-6(-/-) mice after TAC. The extents of LV remodeling, fibrosis, and apoptosis were reduced in IL-6(-/-) hearts after TAC. Transcriptional and protein assays of myocardial tissue identified Ca(2+)/calmodulin-dependent protein kinase II (CaMKII) and signal transducer and activator of transcription 3 (STAT3) activation as important underlying mechanisms during cardiac hypertrophy induced by TAC. The involvement of these pathways in myocyte hypertrophy was verified in isolated cardiac myocytes from wild-type and IL-6(-/-) mice exposed to prohypertrophy agents. Furthermore, overexpression of CaMKII in H9c2 cells increased STAT3 phosphorylation, and exposure of H9c2 cells to IL-6 resulted in STAT3 activation that was attenuated by CaMKII inhibition. Together, these results identify the importance of CaMKII-dependent activation of STAT3 during cardiac myocyte hypertrophy via IL-6 signaling. CONCLUSIONS: Genetic deletion of IL-6 attenuates TAC-induced LV hypertrophy and dysfunction, indicating a critical role played by IL-6 in the pathogenesis of LV hypertrophy in response to pressure overload. CaMKII plays an important role in IL-6-induced STAT3 activation and consequent cardiac myocyte hypertrophy. These findings may have significant therapeutic implications for LV hypertrophy and failure in patients with hypertension.


Assuntos
Deleção de Genes , Ventrículos do Coração/metabolismo , Hipertrofia Ventricular Esquerda/metabolismo , Interleucina-6/metabolismo , Disfunção Ventricular , Animais , Apoptose , Proteína Quinase Tipo 2 Dependente de Cálcio-Calmodulina/metabolismo , Linhagem Celular , Células Cultivadas , Fibrose , Ventrículos do Coração/patologia , Hipertrofia Ventricular Esquerda/genética , Interleucina-6/genética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fator de Transcrição STAT3/metabolismo , Transdução de Sinais
18.
Pacing Clin Electrophysiol ; 41(11): 1491-1494, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30191582

RESUMO

BACKGROUND: A wearable cardioverter defibrillator (WCD) is an alternative for patients who are not immediate candidates for an implantable cardioverter defibrillator (ICD). METHODS: Retrospective analysis of 242 patients prescribed a WCD from January 2014 through March 2015 with 1-year follow-up. RESULTS: A WCD was prescribed to 242 patients during the 15-month period. Forty-one patients were excluded due to lack of complete follow-up. The remaining 201 patients received a WCD for primary or secondary prevention of SCD. Seventy-nine percent of WCDs were prescribed by nonelectrophysiologists. Underlying etiologies for the WCD prescription included: 38% nonischemic cardiomyopathy, 25% recent myocardial infarction, 16% newly diagnosed ischemic cardiomyopathy, 12% documented ventricular arrhythmia, 6% ICD lead extraction, and 3% had high risk conditions for sudden cardiac death. During 1-year follow-up, 96 patients (48%) received an ICD and five patients (2.5%) received appropriate shocks and one patient (0.5 %) received an inappropriate shock. Other 105 (52%) patients subsequently did not require an ICD due to either improvement in ejection fraction, refusal of ICD therapy, or death. CONCLUSIONS: About half of patients prescribed a WCD subsequently receive an ICD and the rate of appropriate shock therapy from the WCD is 2.5%.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 28(8): 853-861, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28497899

RESUMO

BACKGROUND: A significant proportion of patients treated with warfarin for atrial fibrillation (AF) become warfarin ineligible (WI) due to major bleeding events (MBE) or systemic thromboembolism (STE). We report a large multicenter real-world experience of the use of direct oral antagonists (DOACs) in these WI patients. METHODS: We report the outcomes of 263 WI patients treated with DOACs. The primary objective was to evaluate clinical outcomes of STE and MBE with DOACs. Secondary objective was to assess clinical predictors of repeat MBE and STE on DOACs. RESULTS: Note that 63% (166 of 263) patients had a repeat MBE on DOACs. Repeat MBE was significantly higher in patients with prior gastrointestinal bleeding (74.5% vs. 30%, P < 0.0001). Five percent (12 of 263) developed repeat STE. Higher mean CHA2DS2VASC (6.5 ± 1.7 vs. 3.3 ± 1.6 = 0.001) score was associated with repeat STE. About 34% (57 of 166) of patients had an intervention to manage repeat MBE. LAAO devices were successfully used in 67% (12 of 18) high-risk patients who underwent major interventions to manage MBE. CONCLUSION: In WI patients rechallenged with DOACs, a significant proportion developed repeat MBE. LAAO devices seem reasonable in those patients who undergo major interventions to manage MBE with cautious and temporary continuation of DOAC.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/epidemiologia , Substituição de Medicamentos , Hemorragia/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Varfarina/administração & dosagem , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Substituição de Medicamentos/efeitos adversos , Feminino , Seguimentos , Hemorragia/induzido quimicamente , Hemorragia/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/induzido quimicamente , Acidente Vascular Cerebral/diagnóstico , Falha de Tratamento , Varfarina/efeitos adversos
20.
J Cardiovasc Electrophysiol ; 28(2): 139-146, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27943538

RESUMO

BACKGROUND: There have been an increasing number of atrial fibrillation (AF) patients with Watchman left atrial appendage occlusion (LAAO) device, requiring catheter ablation (CA) for maintenance of normal sinus rhythm. In this study, we describe our experience with the feasibility and safety of CA in patients with a preexisting Watchman LAAO device. METHODS: This was a retrospective multicenter AF registry of 60 patients with Watchman LAAO device who underwent CA for AF. Baseline clinical and procedural characteristics of the included subjects were retrieved from review of medical records and were analyzed. RESULTS: The mean age was 72.7 ± 4.9 years and the mean CHADS2 score was 2.3 ± 0.6. All patients had successful pulmonary vein isolation (PVI). The left atrial appendage (LAA) was electrically active in 34 (56%) while reentrant tachycardia and AF triggers were seen in 17 (28%) patients. Electrical isolation was attempted in these 17 patients with only 10 achieving complete LAA isolation. Repeat imaging showed new peri-device leaks in 30% (12/40) patients, while new significant peri-device leaks (≥5 mm) were noted in 10% (10/40) of patients after RFA, respectively, requiring continuation of oral anticoagulation. There were a higher proportion of patients with severe peri-device leaks (≥5 mm) after LAA isolation. However, >50% of those leaks sealed off on follow-up transesophageal echocardiogram. CONCLUSION: AF ablation is a feasible and safe in patients with preexisting Watchman LAAO device. Electrical isolation of the LAA could be difficult and when attempted can result in increased risk of short-term peri-device leak and recurrence of AT/AF in almost all patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/instrumentação , Ablação por Cateter , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Potenciais de Ação , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA