Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Cardiol ; : 132340, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38992809

RESUMO

BACKGROUND: The current incidence and outcomes of structural transcatheter procedures in heart transplant (HTx) recipients and left-ventricular assist devices (LVAD) carriers is unknown. AIMS: To provide insights on structural transcatheter procedures performed across HTx and LVAD patients in Spain. METHODS: Multicenter, ambispective, observational nationwide registry. RESULTS: Until May/2023, 36 percutaneous structural interventions were performed (78% for HTx and 22% for LVAD) widely varying among centers (0%-1.4% and 0%-25%, respectively). Percutaneous mitral transcatheter edge-to-edge (TEER) was the most common (n = 12, 33.3%), followed by trancatheter aortic valve replacement (n = 11, 30.5%), and tricuspid procedures (n = 9, 25%). Mitral TEER resulted in mild residual mitral regurgitation in all but one case, mean gradient was <5 mmHg in 75% of them at 1-year, with no mortality and 8.3% re-admission rate. Tricuspid TEER resulted in 100% none/mild residual regurgitation with a 1-year mortality and readmission rates of 22% and 28.5%, respectively. Finally, trancatheter aortic valve replacement procedures (n = 8 in LVADs due to aortic regurgitation and n = 3 in HTx), were successful in all cases with one prosthesis degeneration leading to severe aortic regurgitation at 1-year, 18.2% mortality rate and no re-admissions. Globally, major bleeding rates were 7.9% and 12.5%, thromboembolic events 3.7% and 12.5%, readmissions 37% and 25%, and mortality 22% and 25%, in HTx and LVADs respectively. No death was related to the implanted transcatheter device. CONCLUSIONS: Most centers with HTx/LVAD programs perform structural percutaneous procedures but with very inconsistent incidence. They were associated with good safety and efficacy, but larger studies are required to provide formal recommendations.

2.
Echocardiography ; 28(4): 388-96, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21504463

RESUMO

AIMS: To compare the measurements of the aortic annulus obtained with various imaging techniques in patients with severe aortic stenosis scheduled for transcatheter aortic valve implantation, and to determine the grade of agreement between the predicted size of the prosthesis for each technique, and the size of the finally implanted valve. METHODS AND RESULTS: The aortic annulus was measured in 40 patients treated by transcatheter aortic valve implantation (CoreValve aortic valve) with transthoracic (TTE) and transesophageal echocardiography (TEE), 64-slice tomography, and angiography. A large valve was implanted when annulus was >23 mm and a small one if it was ≤23 mm. If the size of the prosthesis predicted by several techniques was not the same in one case, we selected the size in which more techniques presented agreement. Forty aortic valves, 26 small and 14 large, were implanted percutaneously. The best correlation was obtained with TTE and TEE (r = 0.93, P < 0.001). The correlation of TTE and TEE with angiography also was good (r = 0.58, P < 0.001 and r = 0.53, P < 0.001, respectively). Correlations between these techniques and computed tomography were poor (P = NS for all comparisons). The best agreement between estimated aortic annulus and implanted valve size was obtained with transtoracic and TEE (κ= 0.88 and 0.76). CONCLUSIONS: The aortic annulus measurements obtained by TTE, TEE, and angiography correlated well, while tomography correlated poorly with other techniques. The imaging techniques that showed the best agreement between estimated aortic annulus size and implanted aortic valve size were TTE and TEE.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/métodos , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA