Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Physiol Heart Circ Physiol ; 326(6): H1446-H1461, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38578237

RESUMO

Clinical failure of arteriovenous neointimal hyperplasia (NIH) fistulae (AVF) is frequently due to juxta-anastomotic NIH (JANIH). Although the mouse AVF model recapitulates human AVF maturation, previous studies focused on the outflow vein distal to the anastomosis. We hypothesized that the juxta-anastomotic area (JAA) has increased NIH compared with the outflow vein. AVF was created in C57BL/6 mice without or with chronic kidney disease (CKD). Temporal and spatial changes of the JAA were examined using histology and immunofluorescence. Computational techniques were used to model the AVF. RNA-seq and bioinformatic analyses were performed to compare the JAA with the outflow vein. The jugular vein to carotid artery AVF model was created in Wistar rats. The neointima in the JAA shows increased volume compared with the outflow vein. Computational modeling shows an increased volume of disturbed flow at the JAA compared with the outflow vein. Endothelial cells are immediately lost from the wall contralateral to the fistula exit, followed by thrombus formation and JANIH. Gene Ontology (GO) enrichment analysis of the 1,862 differentially expressed genes (DEG) between the JANIH and the outflow vein identified 525 overexpressed genes. The rat jugular vein to carotid artery AVF showed changes similar to the mouse AVF. Disturbed flow through the JAA correlates with rapid endothelial cell loss, thrombus formation, and JANIH; late endothelialization of the JAA channel correlates with late AVF patency. Early thrombus formation in the JAA may influence the later development of JANIH.NEW & NOTEWORTHY Disturbed flow and focal endothelial cell loss in the juxta-anastomotic area of the mouse AVF colocalizes with acute thrombus formation followed by late neointimal hyperplasia. Differential flow patterns between the juxta-anastomotic area and the outflow vein correlate with differential expression of genes regulating coagulation, proliferation, collagen metabolism, and the immune response. The rat jugular vein to carotid artery AVF model shows changes similar to the mouse AVF model.


Assuntos
Derivação Arteriovenosa Cirúrgica , Hiperplasia , Veias Jugulares , Camundongos Endogâmicos C57BL , Neointima , Ratos Wistar , Trombose , Animais , Trombose/fisiopatologia , Trombose/patologia , Trombose/genética , Trombose/etiologia , Trombose/metabolismo , Masculino , Veias Jugulares/metabolismo , Veias Jugulares/patologia , Veias Jugulares/fisiopatologia , Modelos Animais de Doenças , Artérias Carótidas/patologia , Artérias Carótidas/fisiopatologia , Artérias Carótidas/metabolismo , Artérias Carótidas/cirurgia , Camundongos , Ratos , Fluxo Sanguíneo Regional , Endotélio Vascular/metabolismo , Endotélio Vascular/fisiopatologia , Endotélio Vascular/patologia , Insuficiência Renal Crônica/patologia , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/genética , Insuficiência Renal Crônica/metabolismo , Células Endoteliais/metabolismo , Células Endoteliais/patologia
2.
Am J Physiol Heart Circ Physiol ; 325(1): H77-H88, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37145957

RESUMO

Arteriovenous fistulae (AVF) fail to mature more frequently in female patients compared with male patients, leading to inferior outcomes and decreased utilization. Since our mouse AVF model recapitulates sex differences in human AVF maturation, we hypothesized that sex hormones mediate these differences during AVF maturation. C57BL/6 mice (9-11 wk) were treated with aortocaval AVF surgery and/or gonadectomy. AVF hemodynamics were measured via ultrasound (days 0-21). Blood was collected for FACS and tissue for immunofluorescence and ELISA (days 3 and 7); wall thickness was assessed by histology (day 21). Inferior vena cava shear stress was higher in male mice (P = 0.0028) after gonadectomy, and they had increased wall thickness (22.0 ± 1.8 vs. 12.7 ± 1.2 µm; P < 0.0001). Conversely, female mice had decreased wall thickness (6.8 ± 0.6 vs. 15.3 ± 0.9 µm; P = 0.0002). Intact female mice had higher proportions of circulating CD3+ T cells on day 3 (P = 0.0043), CD4+ (P = 0.0003) and CD8+ T cells (P = 0.005) on day 7, and CD11b+ monocytes on day 3 (P = 0.0046). After gonadectomy, these differences disappeared. In intact female mice, CD3+ T cells (P = 0.025), CD4+ T cells (P = 0.0178), CD8+ T cells (P = 0.0571), and CD68+ macrophages (P = 0.0078) increased in the fistula wall on days 3 and 7. This disappeared after gonadectomy. Furthermore, female mice had higher IL-10 (P = 0.0217) and TNF-α (P = 0.0417) levels in their AVF walls than male mice. Sex hormones mediate AVF maturation, suggesting that hormone receptor signaling may be a target to improve AVF maturation.NEW & NOTEWORTHY After arteriovenous fistula creation, females have lower rates of maturation and higher rates of failure than males. In a mouse model of venous adaptation that recapitulates human fistula maturation, sex hormones may be mechanisms of the sexual dimorphism: testosterone is associated with reduced shear stress, whereas estrogen is associated with increased immune cell recruitment. Modulating sex hormones or downstream effectors suggests sex-specific therapies and could address disparities in sex differences in clinical outcomes.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Humanos , Masculino , Feminino , Camundongos , Animais , Linfócitos T CD8-Positivos , Maturidade Sexual , Camundongos Endogâmicos C57BL , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Modelos Animais de Doenças , Testosterona , Imunidade , Diálise Renal
3.
Sensors (Basel) ; 23(2)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36679412

RESUMO

To assess pathological gaits quantitatively, three-dimensional coordinates estimated with a deep learning model were converted into body axis plane projections. First, 15 healthy volunteers performed four gait patterns; that is, normal, shuffling, short-stepped, and wide-based gaits, with the Three-Dimensional Pose Tracker for Gait Test (TDPT-GT) application. Second, gaits of 47 patients with idiopathic normal pressure hydrocephalus (iNPH) and 92 healthy elderly individuals in the Takahata cohort were assessed with the TDPT-GT. Two-dimensional relative coordinates were calculated from the three-dimensional coordinates by projecting the sagittal, coronal, and axial planes. Indices of the two-dimensional relative coordinates associated with a pathological gait were comprehensively explored. The candidate indices for the shuffling gait were the angle range of the hip joint < 30° and relative vertical amplitude of the heel < 0.1 on the sagittal projection plane. For the short-stepped gait, the angle range of the knee joint < 45° on the sagittal projection plane was a candidate index. The candidate index for the wide-based gait was the leg outward shift > 0.1 on the axial projection plane. In conclusion, the two-dimensional coordinates on the body axis projection planes calculated from the 3D relative coordinates estimated by the TDPT-GT application enabled the quantification of pathological gait features.


Assuntos
Aprendizado Profundo , Aplicativos Móveis , Humanos , Idoso , Marcha , Articulação do Joelho , Articulação do Quadril , Fenômenos Biomecânicos
4.
Sensors (Basel) ; 23(22)2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-38005649

RESUMO

We aimed to capture the fluctuations in the dynamics of body positions and find the characteristics of them in patients with idiopathic normal pressure hydrocephalus (iNPH) and Parkinson's disease (PD). With the motion-capture application (TDPT-GT) generating 30 Hz coordinates at 27 points on the body, walking in a circle 1 m in diameter was recorded for 23 of iNPH, 23 of PD, and 92 controls. For 128 frames of calculated distances from the navel to the other points, after the Fourier transforms, the slopes (the representatives of fractality) were obtained from the graph plotting the power spectral density against the frequency in log-log coordinates. Differences in the average slopes were tested by one-way ANOVA and multiple comparisons between every two groups. A decrease in the absolute slope value indicates a departure from the 1/f noise characteristic observed in healthy variations. Significant differences in the patient groups and controls were found in all body positions, where patients always showed smaller absolute values. Our system could measure the whole body's movement and temporal variations during walking. The impaired fluctuations of body movement in the upper and lower body may contribute to gait and balance disorders in patients.


Assuntos
Hidrocefalia de Pressão Normal , Doença de Parkinson , Humanos , Captura de Movimento , Smartphone , Caminhada , Marcha
5.
Sensors (Basel) ; 23(13)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37448065

RESUMO

Distinguishing pathological gait is challenging in neurology because of the difficulty of capturing total body movement and its analysis. We aimed to obtain a convenient recording with an iPhone and establish an algorithm based on deep learning. From May 2021 to November 2022 at Yamagata University Hospital, Shiga University, and Takahata Town, patients with idiopathic normal pressure hydrocephalus (n = 48), Parkinson's disease (n = 21), and other neuromuscular diseases (n = 45) comprised the pathological gait group (n = 114), and the control group consisted of 160 healthy volunteers. iPhone application TDPT-GT captured the subjects walking in a circular path of about 1 meter in diameter, a markerless motion capture system, with an iPhone camera, which generated the three-axis 30 frames per second (fps) relative coordinates of 27 body points. A light gradient boosting machine (Light GBM) with stratified k-fold cross-validation (k = 5) was applied for gait collection for about 1 min per person. The median ability model tested 200 frames of each person's data for its distinction capability, which resulted in the area under a curve of 0.719. The pathological gait captured by the iPhone could be distinguished by artificial intelligence.


Assuntos
Inteligência Artificial , Captura de Movimento , Humanos , Marcha , Caminhada , Algoritmos , Fenômenos Biomecânicos , Movimento (Física)
6.
Sensors (Basel) ; 22(14)2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35890959

RESUMO

To quantitatively assess pathological gait, we developed a novel smartphone application for full-body human motion tracking in real time from markerless video-based images using a smartphone monocular camera and deep learning. As training data for deep learning, the original three-dimensional (3D) dataset comprising more than 1 million captured images from the 3D motion of 90 humanoid characters and the two-dimensional dataset of COCO 2017 were prepared. The 3D heatmap offset data consisting of 28 × 28 × 28 blocks with three red-green-blue colors at the 24 key points of the entire body motion were learned using the convolutional neural network, modified ResNet34. At each key point, the hottest spot deviating from the center of the cell was learned using the tanh function. Our new iOS application could detect the relative tri-axial coordinates of the 24 whole-body key points centered on the navel in real time without any markers for motion capture. By using the relative coordinates, the 3D angles of the neck, lumbar, bilateral hip, knee, and ankle joints were estimated. Any human motion could be quantitatively and easily assessed using a new smartphone application named Three-Dimensional Pose Tracker for Gait Test (TDPT-GT) without any body markers or multipoint cameras.


Assuntos
Aprendizado Profundo , Fenômenos Biomecânicos , Marcha , Humanos , Movimento (Física) , Smartphone
7.
Vascular ; 25(2): 123-129, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27206469

RESUMO

Purposes The aim of this study was to evaluate the risk factors for the two-year survival after revascularization of critical limb ischemia. Methods Between 2008 and 2012, 142 patients underwent revascularization. A retrospective analysis was performed to measure the risk factor. Results A total 85 patients underwent surgical revascularization, 31 patients underwent endovascular therapy while 26 patients underwent hybrid therapy. By multivariate analysis, the following variables were considered to be risk factors: ejection fraction <50 % (HR, 3.14; 95% CI, 1.22-7.95; P = 0.02), serum albumin level <2.5 g/dL (HR, 3.45; 95% CI, 1.01-11.7; P = 0.04) and nonambulatory status (HR, 4.11; 95% CI, 1.79-9.70; P < 0.01). The two-year survival rate of the patients with no risk factors was 85.5%, while the patients with at least one risk factor had an unfavorable prognosis (one; 56.7%, two; 45.4%). Conclusions The nonambulatory status, serum albumin level <2.5 g/dL and ejection fraction <50% were the risk factors for the two-year mortality after revascularization in critical limb ischemia patients. These risk factors may be useful for the treatment strategy of critical limb ischemia patients.


Assuntos
Procedimentos Endovasculares/mortalidade , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/terapia , Procedimentos Cirúrgicos Vasculares/mortalidade , Idoso , Biomarcadores/sangue , Estado Terminal , Procedimentos Endovasculares/efeitos adversos , Feminino , Nível de Saúde , Humanos , Hipoalbuminemia/sangue , Hipoalbuminemia/mortalidade , Isquemia/diagnóstico por imagem , Isquemia/mortalidade , Estimativa de Kaplan-Meier , Masculino , Limitação da Mobilidade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Albumina Sérica/análise , Albumina Sérica Humana , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos
8.
Vascular ; 25(1): 36-41, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26993143

RESUMO

Purpose Our objective was to compare the radial forces of several stents ex vivo to identify stents suitable for rescue of the unexpected coverage of aortic arch branches in thoracic endovascular aortic repair. Methods We measured the radial forces of two types of self-expanding bare nitinol stents (E-luminexx and Epic) used singly or as double-walled pairs, and of three endoprostheses used in thoracic endovascular aortic repair (TEVAR, Gore c-TAG, Relay, and Valiant) by compressing the stent using an MTS Instron universal testing machine (model #5582). We also examined the compressive effects of the TEVAR endoprostheses and the bare nitinol stents on each other. Results The radial force was greater in the center than at the edge of each stent. In all stents tested, the radial force decreased incrementally with increasing stent diameter. The radial force at the center was two times greater when using two stents than with a single stent. In the compression test, only E-luminexx used as a pair was not compressed after compressing a Relay endoprosthesis by 12 mm. Conclusion Two E-luminexx stents are appropriate to restore the blood flow if a TEVAR endoprosthesis covers the innominate artery following innominate-carotid-left subclavian arterial bypass.


Assuntos
Ligas , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Tronco Braquiocefálico/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Tronco Braquiocefálico/diagnóstico por imagem , Tronco Braquiocefálico/fisiopatologia , Angiografia por Tomografia Computadorizada , Humanos , Teste de Materiais , Desenho de Prótese , Fluxo Sanguíneo Regional , Estresse Mecânico
9.
Vascular ; 24(4): 348-54, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26223528

RESUMO

PURPOSE: The purpose of this study was to investigate the operative mortality and short-term and midterm outcomes of treatment of abdominal aortic aneurysm in Japanese patients over 80 years of age. METHODS: Between January 2007 and December 2011, 207 patients underwent elective repair of infrarenal abdominal aortic aneurysms. Comorbidities, operative morbidity and mortality, midterm outcomes were analyzed retrospectively. RESULTS: The average age (endovascular aneurysm repair, 84.4 ± 0.3; open, 82.8 ± 0.3, P < 0.01) and the percentage of hostile abdomen (endovascular aneurysm repair, 22.2%; open repair, 11.1%, P < 0.05) were higher in the endovascular aneurysm repair group. Percentage of outside IFU was higher in open repair (endovascular aneurysm repair, 38.5%; open repair, 63.3%, P < 0.01). The cardiac complication (endovascular aneurysm repair, 0%; open repair, 5.6%, P < 0.01) and length of postoperative hospital stay (endovascular aneurysm repair, 10.3 ± 0.8 days; open, 18.6 ± 1.6 days, P < 0.05) were significantly lower in the endovascular aneurysm repair group. There were no differences in operative mortality (endovascular aneurysm repair, 0%; open, 1.1%, P = 0.43) and the aneurysm-related death was not observed. The rate of secondary interventions (EVAR, 5.1%; open repair, 0%, P < 0.01) and midterm mortality rate were much higher in the endovascular aneurysm repair group. CONCLUSIONS: Endovascular aneurysm repair is less invasive than open repair and useful for treating abdominal aortic aneurysm in octogenarians; however, open repair can be acceptable treatment in the inappropriate case treated by endovascular aneurysm repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Fatores Etários , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Japão , Tempo de Internação , Masculino , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Vascular ; 24(2): 171-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26041700

RESUMO

BACKGROUND AND PURPOSE: Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. MATERIAL AND METHODS: We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. RESULTS: Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P < 0.01). The radial force of the thoracic stents was greater than that of all three endovascular stents (P < 0.01). CONCLUSIONS: Differences in radial force depend on types of stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Aorta Torácica/fisiopatologia , Hemodinâmica , Humanos , Teste de Materiais , Modelos Cardiovasculares , Desenho de Prótese , Fluxo Sanguíneo Regional , Estresse Mecânico
11.
J Vasc Surg ; 61(4): 945-50, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25498160

RESUMO

BACKGROUND: Sarcopenia has been proposed as a prognostic factor for various diseases. Patients with critical limb ischemia (CLI) have a very poor prognosis, but sarcopenia has not been reported as a prognostic factor for CLI patients. If sarcopenia is associated with the prognosis of CLI patients, it could help select the treatment plan. Therefore, we examined whether sarcopenia is a prognostic factor for CLI patients. METHODS: We performed a retrospective study of CLI patients diagnosed with Fontaine III or IV peripheral artery disease who underwent preoperative computed tomography imaging and revascularization between January 2002 and December 2009. The presence of sarcopenia was defined as skeletal muscle area of <114.0 cm(2) for men or <89.8 cm(2) for women using transverse computed tomography scans at the third lumbar vertebra. We compared the 5-year survival rate and clinical characteristics between patients with or without sarcopenia. We also screened possible prognostic factors for overall survival using hazard ratios (HRs) with 95% confidence intervals (CIs). RESULTS: Of 64 eligible patients, 28 patients had sarcopenia and 36 did not. There were significant differences in age, skeletal muscle area, body mass index, and the presence of smoking, cerebrovascular disease, and hemodialysis between patients with and without sarcopenia (all P < .05). The 5-year survival rate was significantly lower in patients with sarcopenia (23.5% vs 77.5%, P = .001). Prognostic factors for overall survival were the presence of sarcopenia (HR, 3.22; 95% CI, 1.24-9.11; P = .02), requirement for hemodialysis (HR, 4.30; 95% CI, 1.60-12.2; P = .004), and postoperative complications (HR, 5.02; 95% CI, 1.90-13.7; P = .001). CONCLUSIONS: Our results suggest that sarcopenia is a prognostic factor for CLI patients. Exercise and nutritional interventions focusing on improving sarcopenia might be useful treatment options for CLI patients.


Assuntos
Isquemia/cirurgia , Extremidade Inferior/irrigação sanguínea , Sarcopenia/complicações , Procedimentos Cirúrgicos Vasculares , Idoso , Idoso de 80 Anos ou mais , Músculos do Dorso/diagnóstico por imagem , Índice de Massa Corporal , Estado Terminal , Feminino , Humanos , Isquemia/complicações , Isquemia/diagnóstico , Isquemia/mortalidade , Estimativa de Kaplan-Meier , Nefropatias/complicações , Nefropatias/terapia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Modelos de Riscos Proporcionais , Diálise Renal , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sarcopenia/diagnóstico , Sarcopenia/mortalidade , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
12.
Vascular ; 23(4): 436-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25245045

RESUMO

A 69-year-old male visited a doctor with dyspnea. A bronchial-pulmonary artery fistula, which is called racemose hemangioma, and dilated pulmonary artery were detected by a computed tomography (CT) scan. The bronchial-pulmonary artery fistula can cause lethal hemoptysis, therefore, we performed thoracic endovascular aortic repair (TEVAR) to seal the bronchial artery and coil embolization of the pulmonary artery. Postoperative CT showed the thrombosed racemose hemangioma of the bronchial artery. TEVAR and coil embolization of the pulmonary artery is considered to be a useful treatment option for a racemose hemangioma.


Assuntos
Aorta Torácica/cirurgia , Fístula Artério-Arterial/terapia , Implante de Prótese Vascular , Artérias Brônquicas/cirurgia , Embolização Terapêutica , Procedimentos Endovasculares , Hemangioma/terapia , Artéria Pulmonar , Idoso , Fístula Artério-Arterial/congênito , Fístula Artério-Arterial/diagnóstico , Artérias Brônquicas/anormalidades , Hemangioma/congênito , Hemangioma/diagnóstico , Humanos , Masculino , Artéria Pulmonar/anormalidades , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Fukuoka Igaku Zasshi ; 106(9): 254-61, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26742218

RESUMO

OBJECTIVE: To evaluate the efficacy of hybrid procedure for peripheral arterial disease (PAD), we compared the cases treated using the hybrid procedure with those treated using open revascularization (bypass alone) in our facilities. MATERIALS AND METHODS: We retrospectively reviewed 204 patients who underwent revascularization for PAD between 2007 and 2013. We divided the patients into two groups based on the type of procedure. Group 1 included patients who underwent the hybrid procedure, that is, doing endovascular therapy (EVT) either femoral or iliac resion and added the bypass procedure (infragenicular vein bypass) to the below knee artery, and group 2 included patients who underwent only bypass procedure (used autovein), that is, central anastomotic region was femoral artery region and peripheral anastomotic region was below knee artery. We evaluated various factors between the two groups, including the primary patency rate, secondary patency rate, amputation-free survival rate, and determined the efficacy of the hybrid procedure for PAD. RESULTS: In the patient's characteristics, there was significant difference between the two groups in the cases with cerebrovascular disease, only (p = 0.03). There were no significant differences in the primary or secondary patency rates, and the amputation-free survival rate. CONCLUSIONS: Primary patency rate, secondary patency rate, and amputation-free survival rate of the hybrid procedure were comparable to those of bypass (alone) procedure. The hybrid procedure is therefore an acceptable strategy for patients with PAD.


Assuntos
Doença Arterial Periférica/epidemiologia , Idoso , Feminino , Humanos , Masculino , Doença Arterial Periférica/cirurgia , Reoperação , Estudos Retrospectivos , Enxerto Vascular
14.
Fukuoka Igaku Zasshi ; 105(11): 214-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25816565

RESUMO

We herein report a case of a late type III endoleak caused by disconnection of the aorta extension and main body of a Powerlink four years after implantation. Migration of the main body caused a disconnection of the main body and extension despite the fact that the size of the aneurysm had been decreasing. The endoleak was successfully repaired using the interpolation of an Endurant aortic extender. In case of necessity of implantation of the extension, first implantation of extension before deploying the main body may help to prevent type III endoleaks caused by disconnection of the stentgraft in patients treated with the Powerlink system. To our knowledge, this is the first reported case of a late type III endoleak caused by a Powerlink device.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Endoleak/etiologia , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/etiologia , Stents/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/prevenção & controle , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/terapia , Fatores de Tempo , Resultado do Tratamento
15.
Sci Rep ; 14(1): 13287, 2024 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858395

RESUMO

Clinical outcomes of arteriovenous fistulae (AVF) for hemodialysis remain inadequate since biological mechanisms of AVF maturation and failure are still poorly understood. Aortocaval fistula creation (AVF group) or a sham operation (sham group) was performed in C57BL/6 mice. Venous limbs were collected on postoperative day 7 and total RNA was extracted for high throughput RNA sequencing and bioinformatic analysis. Genes in metabolic pathways were significantly downregulated in the AVF, whereas significant sex differences were not detected. Since gene expression patterns among the AVF group were heterogenous, the AVF group was divided into a 'normal' AVF (nAVF) group and an 'outliers' (OUT) group. The gene expression patterns of the nAVF and OUT groups were consistent with previously published data showing venous adaptive remodeling, whereas enrichment analyses showed significant upregulation of metabolism, inflammation and coagulation in the OUT group compared to the nAVF group, suggesting the heterogeneity during venous remodeling reflects early gene expression changes that may correlate with AVF maturation or failure. Early detection of these processes may be a translational strategy to predict fistula failure and reduce patient morbidity.


Assuntos
Derivação Arteriovenosa Cirúrgica , Camundongos Endogâmicos C57BL , Remodelação Vascular , Animais , Camundongos , Masculino , Remodelação Vascular/genética , Feminino , Regulação para Baixo/genética , Veias/metabolismo , Diálise Renal , Fístula Arteriovenosa/genética , Fístula Arteriovenosa/metabolismo , Fístula Arteriovenosa/patologia , Regulação da Expressão Gênica , Perfilação da Expressão Gênica
16.
JVS Vasc Sci ; 5: 100191, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510938

RESUMO

Objective: A central arteriovenous fistula (AVF) has been proposed as a potential novel solution to treat patients with refractory hypertension. We hypothesized that venous remodeling after AVF creation in the hypertensive environment reduces systemic blood pressure but results in increased AVF wall thickness compared with remodeling in the normotensive environment. Methods: A central AVF was performed in C57BL6/J mice previously made hypertensive with angiotensin II (Ang II); mice were sacrificed on postoperative day 7 or 21. Results: In mice treated with Ang II alone, the mean systolic blood pressure increased from 90 ± 5 mmHg to 160 ± 5 mmHg at day 21; however, in mice treated with both Ang II and an AVF, the blood pressure decreased with creation of an AVF. There were significantly more PCNA-positive cells, SM22α/PCNA-positive cells, collagen I deposition, and increased Krüppel-like Factor 2 immunoreactivity in hypertensive mice with an AVF compared with normotensive mice with an AVF. Conclusions: These data show that a central AVF decreases systemic hypertension as well as induces local alterations in venous remodeling.

17.
Front Aging Neurosci ; 13: 653964, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33790781

RESUMO

Background: The subjective evaluation of pathological gait exhibits a low inter-rater reliability. Therefore, we developed a three-dimensional acceleration of the trunk during walking to assess the pathological gait quantitatively. Methods: We evaluated 97 patients who underwent the cerebrospinal tap test and were diagnosed with idiopathic normal pressure hydrocephalus (iNPH) and 68 healthy elderlies. The gait features of all patients were evaluated and classified as one of the following: freezing of gait, wide-based gait, short-stepped gait, shuffling gait, instability, gait festination, difficulty in changing direction, and balance disorder in standing up. All gait features of 68 healthy elderlies were treated as normal. Trunk acceleration was recorded automatically by a smartphone placed on the umbilicus during a 15-foot walking test. Two novel indices were created. The first index was a trunk acceleration index, which was defined as (forward acceleration fluctuation) + (vertical acceleration fluctuation) - (lateral acceleration fluctuation) based on the multivariate logistics regression model, and the second index was created by multiplying the forward acceleration with the vertical acceleration. Additionally, 95% confidence ellipsoid volume of the three-dimensional accelerations was assessed. Results: Forward and vertical acceleration fluctuations were significantly associated with the probability of an iNPH-specific pathological gait. The trunk acceleration index demonstrated the strongest association with the probability of an iNPH-specific pathological gait. The areas under the receiver-operating characteristic curves for detecting 100% probability of an iNPH-specific pathological gait were 86.9% for forward acceleration fluctuation, 88.0% for vertical acceleration fluctuation, 82.8% for lateral acceleration fluctuation, 89.0% for trunk acceleration index, 88.8% for forward × vertical acceleration fluctuation, and 87.8% for 95% confidence ellipsoid volume of the three-dimensional accelerations. Conclusions: The probability of a pathological gait specific to iNPH is high at the trunk acceleration fluctuation, reduced in the forward and vertical directions, and increased in the lateral direction.

18.
Aging Dis ; 10(1): 23-36, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30705765

RESUMO

Although the 3-m timed up-and-go test (TUG) is reliable for evaluating mobility, TUG time is insufficient to evaluate mild gait disturbance; we, therefore aimed to investigate other measurements with instrumented TUG (iTUG) using a free smartphone application. Our inclusion criterion in this study is only that participants can walk without any assistance. This study included three heterogeneous groups; patients who underwent a tap test or shunt surgery, 29 inpatients hospitalized for other reasons, and 87 day-care users. After the tap test, 28 were diagnosed with tap-positive idiopathic normal-pressure hydrocephalus (iNPH) and 8 were diagnosed with tap-negative. Additionally, 18 patients were assessed iTUG before and after shunt surgery. During iTUG, time and 3-dimensional (3D) acceleration were automatically recorded every 0.01 s. A volume of the 95% confidence ellipsoid (95%CE) of all plots for 3D acceleration was calculated. Additionally, an iTUG score was defined as (95%CE volume) 0.8 / 1.9 - 1.9 × (time) + 60. The measurement reliability was evaluated using intraclass correlations and Bland-Altman plots. The participants with mild gait disturbance who accomplished within 13.5 s on the iTUG time had the 95%CE volumes for 3D acceleration of ≥70 m3/s6 and iTUG scores of ≥50. The mean iTUG time was shortened and the mean 95%CE volumes and iTUG scores were increased after the tap test among 28 patients with tap-positive iNPH and after shunt surgery among 18 patients with definite iNPH. Conversely, the mean iTUG score among 8 patients with tap-negative was decreased after the tap test. The intraclass correlations for the time, 95%CE volume and iTUG score were 0.97, 0.80 and 0.90, respectively. Not only the iTUG time but also the 95%CE volume was important for evaluating mobility. Therefore, the novel iTUG score consisting both is useful for the quantitative assessment of mobility.

19.
J Neurol Sci ; 398: 45-49, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30682520

RESUMO

BACKGROUND: The timed-up-and-go test (TUG) is a popular test for mobility, but it only measures the total time to complete tasks. Recent advances in smartphone technology enables measuring respective times of 6 components in the test (Stand, Go, Turn1, Come, Turns and Sit). We examined availability of these data for assessing different gait patterns. METHODS: This study enrolled 32 patients with probable idiopathic normal-pressure hydrocephalus and 87 age-matched active participants as controls. All the patients responded positively to cerebrospinal fluid (CSF) removal, among whom 19 underwent surgery with positive outcomes. The TUG was performed using a free smartphone application. The components were automatically detected, and their respective times were computed. Statistical analyses included item cluster analysis. RESULTS: In the control group, high correlations (r ≥ 0.7) were observed in two pairs of Go and Come, and Turn1 and Turn2, which reflect straight walk and turn. This pattern was lost in the baseline and after CSF removal in the hydrocephalus group. After surgery, the two pairs in the control group regained high correlations. The item cluster analysis showed the pattern changes more clearly. CONCLUSIONS: A smartphone is useful for analyzing gait patterns in the TUG, which can be applicable for various gait disorders.


Assuntos
Análise da Marcha/métodos , Marcha/fisiologia , Hidrocefalia de Pressão Normal/fisiopatologia , Smartphone , Estudos de Tempo e Movimento , Dispositivos Eletrônicos Vestíveis , Idoso , Idoso de 80 Anos ou mais , Feminino , Análise da Marcha/instrumentação , Humanos , Hidrocefalia de Pressão Normal/diagnóstico , Masculino , Smartphone/instrumentação
20.
J Am Heart Assoc ; 8(23): e011911, 2019 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-31787052

RESUMO

Background Angiotensin II (Ang II) can cause hypertension and tissue impairment via AGTR1 (Ang II receptor type 1), particularly in renal proximal tubule cells, and can cause DNA damage in renal cells via nicotinamide adenine dinucleotide phosphate oxidase. BubR1 (budding uninhibited by benzimidazole-related 1) is a multifaceted kinase that functions as a mitotic checkpoint. BubR1 expression can be induced by Ang II in smooth muscle cells in vitro, but the relationship between systemic BubR1 expression and the Ang II response is unclear. Methods and Results Twenty 24-week-old male BubR1 low-expression mice (BubR1L/L mice) and age-matched BubR1+/+ mice were used in this study. We investigated how Ang II stimulation affects BubR1L/L mice. The elevated systolic blood pressure caused by Ang II stimulation in BubR1+/+ mice was significantly attenuated in BubR1L/L mice. Additionally, an attenuated level of Ang II-induced perivascular fibrosis was observed in the kidneys of BubR1L/L mice. Immunohistochemistry revealed that the overexpression of AGTR1 induced by Ang II stimulation was repressed in BubR1L/L mice. We evaluated AGTR1 and Nox-4 (nicotinamide adenine dinucleotide phosphate oxidase-4) levels to determine the role of BubR1 in the Ang II response. Results from in vitro assays of renal proximal tubule cells suggest that treatment with small interfering RNA targeting BubR1 suppressed Ang II-induced overexpression of AGTR1. Similarly, the upregulation in Nox4 and Jun N-terminal kinase induced by Ang II administration was repressed by treatment with small interfering RNA targeting BubR1. Conclusions Ang II-induced hypertension is caused by AGTR1 overexpression in the kidneys via the upregulation of BubR1 and Nox4.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/farmacologia , Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Proteínas de Ciclo Celular/biossíntese , Hipertensão/metabolismo , Hipertensão/prevenção & controle , Proteínas Serina-Treonina Quinases/biossíntese , Receptor Tipo 1 de Angiotensina/biossíntese , Receptor Tipo 1 de Angiotensina/efeitos dos fármacos , Angiotensina II/administração & dosagem , Animais , Hipertensão/induzido quimicamente , Masculino , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA