Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Fluoresc ; 31(4): 933-940, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33782809

RESUMO

Rapid and onsite detection of nitroaromatic explosive 2,4,6-trinitrotoluene (TNT) is very crucial for the safety and security of human life as well as for the environment. In this present work, we demonstrate the feasibility for employing Folic Acid (FA) as a fluorescent as well as a colorimetric probe for the detection of TNT. This probe was synthesized by a simple one-step process. The developed probe shows an emission maximum at 490 nm upon excitation at 420 nm. On adding TNT, the fluorescence of the FA probe is quenched. Also, it shows a good selectivity towards TNT over other similar organic compounds such as 4-nitrophenol (4-NP), 2,4-dinitrophenol (2,4-DNP) and picric acid (PA). The limit of detection (LoD) of TNT was found to be 1.9398 µM. Colorimetric detection was conducted and paper strip assay was developed for the practical applications.


Assuntos
Trinitrotolueno , Ácido Fólico , Pontos Quânticos
2.
J Fluoresc ; 30(6): 1337-1344, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32809112

RESUMO

The present work is an attempt to investigate the heavy atom effect imparted by halide ions, especially iodide (I-) ions on the fluorescence behavior of carbon dots (CDs). Here two different types of CDs viz. nitrogen doped carbon dots (NCDs) from Citric Acid (CA) & Urea and Sulfur and nitrogen co-doped carbon dots (S,N-CDs) from CA & L-Cysteine were synthesized and the fluorescence of both CDs were quenched by heavy atom effect on adding potassium iodide (KI). The large difference in average lifetime was obtained in time-correlated single-photon counting (TCSPC) analysis suggests the dynamic quenching and heavy atom effect. Graphical abstract.

3.
Anal Bioanal Chem ; 412(17): 4165-4172, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32356098

RESUMO

Trinitrotoluene (TNT) is a widely used explosive belonging to the family of nitroaromatic compounds, and its misuse poses a significant threat to society. Herein, we propose a Tb-BSA-AuNC fluorescent and colorimetric sensing probe for the selective onsite detection of TNT in the aqueous phase. Tb-doped BSA-protected gold nanoclusters (Tb-BSA-AuNCs) were synthesized by a microwave-assisted method, and TNT detection was carried out utilizing the chemistry of Meisenheimer complex formation. Tb doping of gold nanoclusters was demonstrated to facilitate better electron shuttling effects and thereby improve the efficiency of complex formation between the TNT and gold nanoclusters. A paper strip assay was also developed for TNT detection with the designed probe. Limits of detection and quantification of 0.2136 mM and 0.7120 mM, respectively, were achieved. Graphical abstract.

4.
Mikrochim Acta ; 185(12): 532, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30402728

RESUMO

A method is described for sensitive and selective fluorometric determination of morphine. It is based on the effect of morphine on quenching of the fluorescence of fluorescein by gold nanoparticles (AuNPs) via surface energy transfer. When fluorescein is added to solutions of colloidal AuNPs, its fluorescence becomes quenched due to nanometal surface energy transfer (NSET) because the absorption of AuNPs strongly overlaps the emission spectrum of fluorescein. In the presence of morphine, which contains both a tertiary nitrogen ring atom and a phenolic hydroxy group, it will coordinate to the AuNPs, and this causes recovery of fluorescence. The presence of a tertiary nitrogen ring atom and a phenolic hydroxy group (both required for the effect to occur) in morphine make the probe highly selective and sensitive for morphine. A paper strip assay also was developed by utilizing this detection scheme. The turn-on fluorescent probe was successfully applied to the determination of morphine in spiked serum and urine samples. The method has a 53 pM limit of detection. The paper strip was applied to the determination of morphine in sweat, urine and other biological fluids. It is perceived to be useful for early detection of drug abuse by adolescent. Graphical abstract Schematic of the mechanism of fluorescence turn on detection of morphine using Au NPs (gold nanoparticles) acting asquencher of the fluorescence of fluorescein.


Assuntos
Fluoresceína/química , Fluorometria/métodos , Ouro/química , Nanopartículas Metálicas/química , Morfina/análise , Transferência de Energia , Corantes Fluorescentes/química , Fluorometria/instrumentação , Humanos , Morfina/sangue , Morfina/urina , Fitas Reagentes/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA