Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Exp Allergy ; 45(7): 1189-200, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25702830

RESUMO

BACKGROUND: The relationship between helminthiases and allergy is a matter of considerable interest and research. In the tropics, house dust mite exposure, a known risk factor for asthma, is frequently concurrent with helminth infections. It remains to be defined whether infection with the common roundworm Ascaris or its bystander immunological effects influence the prevalence and pathogenesis of asthma independently of mite sensitization. OBJECTIVE: To investigate the relationship between the IgE responses to Ascaris and its purified allergens and the risk of asthma in a tropical country. METHODS: A nested case-control study was performed in 356 subjects who reported current and past asthma symptoms (asthmatics) and 435 controls that had never experienced such symptoms. They were tested for serum levels of total IgE and specific IgE to Ascaris extract, Asc s 1 (ABA-1), Asc l 3 (tropomyosin) and GST (glutathione transferase). In addition, specific IgE to Dermatophagoides pteronyssinus, Blomia tropicalis and their tropomyosins Der p 10 and Blo t 10 was measured. Sensitization was defined as a positive specific IgE result to any extract or recombinant allergen. RESULTS: Sensitization to Ascaris and D. pteronyssinus was independently associated with asthma after adjustment for age, gender, socio-economic stratum, city and other IgE levels (adjusted ORs: 2.17; 95% CI 1.37-3.42 and 2.46; 95% CI 1.54-3.92), respectively. There was also a significant association with sensitization to the highly allergenic and cross-reactive tropomyosins Asc l 3, Blo t 10 and Der p10 (aORs: 1.76; 95% CI 1.21-2.57, 1.64; 95% CI 1.14-2.35 and 1.51; 95% CI 1.02-2.24), respectively. CONCLUSION AND CLINICAL RELEVANCE: IgE responses to Ascaris are associated with asthma symptoms in a population living in the tropics. Sensitization to the cross-reactive Ascaris and mite tropomyosins partially underlies this finding. These results have potential relevance in asthma diagnosis and management.


Assuntos
Ascaris/imunologia , Asma/imunologia , Imunoglobulina E/imunologia , Ácaros/imunologia , Tropomiosina/imunologia , Adolescente , Adulto , Fatores Etários , Alérgenos/imunologia , Animais , Especificidade de Anticorpos/imunologia , Asma/epidemiologia , Estudos de Casos e Controles , Criança , Feminino , Humanos , Imunoglobulina E/sangue , Masculino , Pessoa de Meia-Idade , Razão de Chances , Fatores de Risco , Fatores Sexuais , Adulto Jovem
2.
Med Phys ; 42(4): 2006-17, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25832091

RESUMO

PURPOSE: To prove the ability of protons to reproduce a dose gradient that matches a dose painting by numbers (DPBN) prescription in the presence of setup and range errors, by using contours and structure-based optimization in a commercial treatment planning system. METHODS: For two patients with head and neck cancer, voxel-by-voxel prescription to the target volume (GTVPET) was calculated from (18)FDG-PET images and approximated with several discrete prescription subcontours. Treatments were planned with proton pencil beam scanning. In order to determine the optimal plan parameters to approach the DPBN prescription, the effects of the scanning pattern, number of fields, number of subcontours, and use of range shifter were separately tested on each patient. Different constant scanning grids (i.e., spot spacing = Δx = Δy = 3.5, 4, and 5 mm) and uniform energy layer separation [4 and 5 mm WED (water equivalent distance)] were analyzed versus a dynamic and automatic selection of the spots grid. The number of subcontours was increased from 3 to 11 while the number of beams was set to 3, 5, or 7. Conventional PTV-based and robust clinical target volumes (CTV)-based optimization strategies were considered and their robustness against range and setup errors assessed. Because of the nonuniform prescription, ensuring robustness for coverage of GTVPET inevitably leads to overdosing, which was compared for both optimization schemes. RESULTS: The optimal number of subcontours ranged from 5 to 7 for both patients. All considered scanning grids achieved accurate dose painting (1% average difference between the prescribed and planned doses). PTV-based plans led to nonrobust target coverage while robust-optimized plans improved it considerably (differences between worst-case CTV dose and the clinical constraint was up to 3 Gy for PTV-based plans and did not exceed 1 Gy for robust CTV-based plans). Also, only 15% of the points in the GTVPET (worst case) were above 5% of DPBN prescription for robust-optimized plans, while they were more than 50% for PTV plans. Low dose to organs at risk (OARs) could be achieved for both PTV and robust-optimized plans. CONCLUSIONS: DPBN in proton therapy is feasible with the use of a sufficient number subcontours, automatically generated scanning patterns, and no more than three beams are needed. Robust optimization ensured the required target coverage and minimal overdosing, while PTV-approach led to nonrobust plans with excessive overdose. Low dose to OARs can be achieved even in the presence of a high-dose escalation as in DPBN.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/radioterapia , Estudos de Viabilidade , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Órgãos em Risco , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/radioterapia , Reconhecimento Automatizado de Padrão/métodos , Tomografia por Emissão de Pósitrons , Prótons , Radiometria , Compostos Radiofarmacêuticos , Dosagem Radioterapêutica , Carcinoma de Células Escamosas de Cabeça e Pescoço , Fatores de Tempo , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA