Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38363996

RESUMO

AIMS: Controversy remains as to whether the exercise stress test (EST) is sufficient for risk evaluation in patients with pre-excitation. This study aims to clarify the usefulness of EST in risk stratification in both asymptomatic and symptomatic patients presenting with pre-excitation. METHODS AND RESULTS: This prospective study includes consecutive asymptomatic and symptomatic patients with pre-excitation referred for risk assessment. All participants performed an incremental EST (bicycle) prior to an electrophysiology study (EPS). Primary data from the EST included loss of pre-excitation during exercise, and primary data from the EPS included the measurement of accessory pathway effective refractory period (APERP), shortest pre-excited RR interval (SPERRI), and inducible arrhythmia with the use of a beta-adrenergic receptor agonist if deemed necessary. One hundred and sixty-four patients (59 asymptomatic, 105 symptomatic) completed an EST and EPS. Forty-five patients (27%) demonstrated low-risk findings on EST, of which 19 were asymptomatic and 26 were symptomatic. Six patients with low-risk EST findings had SPERRI/APERP ≤ 250 ms at EPS, and two of them were asymptomatic. The sensitivity, specificity, positive predictive value, negative predictive value (NPV), and accuracy of low-risk EST for excluding patients with SPERRI/APERP ≤ 250 ms were 40, 91, 87, 51, and 60%, respectively. The number of patients with inducible arrhythmia at EPS was similar in the asymptomatic (36, 69%) and symptomatic (73, 61%) groups. CONCLUSION: Sudden loss of pre-excitation during EST has a low NPV in excluding high-risk APs. The EPS with the use of isoproterenol should be considered to accurately assess the risk of patients with pre-excitation regardless of symptoms (ClinicalTrials.gov Identifier: NCT03301935).


Assuntos
Feixe Acessório Atrioventricular , Síndromes de Pré-Excitação , Síndrome de Wolff-Parkinson-White , Humanos , Síndrome de Wolff-Parkinson-White/diagnóstico , Estudos Prospectivos , Síndromes de Pré-Excitação/diagnóstico , Feixe Acessório Atrioventricular/diagnóstico , Medição de Risco/métodos , Eletrocardiografia/métodos
2.
J Cardiovasc Electrophysiol ; 32(11): 2953-2960, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34535936

RESUMO

AIMS: This study evaluates the incidence of procedural complications related to catheter ablation of atrial fibrillation (AF) to assess the potential feasibility and safety of same-day discharge in a large cohort. METHODS: We performed an analysis of prospectively collected data of complications of all patients staying overnight after undergoing AF ablation between 2001 and 2020 at a tertiary center. Using medical records, we analyzed complications occurring intraprocedurally until 6 h postablation and between 6 h postablation and discharge the day after the ablation procedure. RESULTS: In 5414 AF ablations, we identified a total of 108 (2.0%) major complications occurring intraprocedural or before discharge. Most major complications occurred intraprocedurally or within 6 h after the procedure (n = 96, 1.8%). Twelve (0.2%) major complications occurred between 6 h Postablation and discharge. The most common of these major complications were congestive heart failure (n = 6) and transient ischemic attack (TIA, n = 4). During this time span, 61 (1.1%) minor complications occurred. Factors independently associated with major complications intraprocedurally and until discharge were body mass index (BMI) ≥ 30 kg/m2 (p = .009), significant valvular disease (p = .001), cardiomyopathy (p < .001), prior stroke or TIA (p = .014), first-time procedure versus repeat procedure (p = .013), cryoablation versus radiofrequency (p < .001), and procedure duration (p < .001). CONCLUSION: After AF ablation, very few complications occurred between 6 h postprocedure and discharge the next day. Therefore, same-day discharge is a safe option for a majority of patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Incidência , Alta do Paciente , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 31(3): 674-681, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31984563

RESUMO

AIMS: To investigate the significance of early recurrence (ER) of atrial tachyarrhythmias after pulmonary vein isolation (PVI) on the development of late recurrence (LR) and to redefine the blanking period during which an ER is considered nonspecific. METHODS: Data of 713 patients undergoing their first PVI for paroxysmal or persistent atrial fibrillation between January 2012 and December 2017 were included. All patients were followed-up for 12 months according to clinical and outpatient routine and were screened for any atrial tachyarrhythmia lasting >30 seconds occurring during the first 3 months postablation (ER) and after the 3 months blanking period (LR). RESULTS: Patients with ER compared to those without ER had significantly more LR (74.5% vs 16.5% vs, P < .001). The occurrence of ER during the first, second and third months showed increasing LR rates of 35.2%, 67.9%, and 94.8%, respectively (P < .001). Receiver operator characteristic analysis revealed a blanking period of 46 days with the highest sensitivity (68.1%) and specificity (96.5%). Later timing and longer time span of ER were independent predictors for LR in multivariable analysis. CONCLUSION: ER is a strong predictor for LR. Our study advocates a shortening of the post-PVI blanking period followed by a "gray zone" up to 3 months where individualized therapeutic decisions based on additional risk factors should be considered. We suggest that the ER time span might serve as such a predictor identifying patients at the highest risk for LR.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Europace ; 22(10): 1547-1557, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32772100

RESUMO

AIMS: Iatrogenic cardiac tamponades are a rare but dreaded complication of invasive electrophysiology procedures (EPs). Their long-term impact on clinical outcomes is unknown. This study analysed the risk of death or serious cardiovascular events in patients suffering from EP-related cardiac tamponade requiring pericardiocentesis during long-term follow-up. METHODS AND RESULTS: Out of 19 997 invasive EPs at the Karolinska University Hospital between January 1998 and September 2018, all patients with EP-related periprocedural cardiac tamponade were identified (n = 60) and matched (1:3 ratio) to a control group (n = 180). After a follow-up of 5 years, the composite primary endpoint - death from any cause, acute myocardial infarction, transitory ischaemic attack (TIA)/stroke, and hospitalization for heart failure - occurred in significantly more patients in the tamponade than in the control group [12 patients (20.0%) vs. 19 patients (10.6%); hazard ratio (HR) 2.53 (95% confidence interval, CI 1.15-5.58); P = 0.021]. This was mainly driven by a higher incidence of TIA/stroke in the tamponade than in the control group [HR 3.75 (95% CI 1.01-13.97); P = 0.049]. Death from any cause, acute myocardial infarction, and hospitalization for heart failure did not show a significant difference between the groups. Hospitalization for pericarditis occurred in significantly more patients in the tamponade than in the control group [HR 36.0 (95% CI 4.68-276.86); P = 0.001]. CONCLUSION: Patients with EP-related cardiac tamponade are at higher risk for cerebrovascular events during the first 2 weeks and hospitalization for pericarditis during the first months after index procedure. Despite the increased risk for early complications tamponade patients have a good long-term prognosis without increased risk for mortality or other serious cardiovascular events.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Ataque Isquêmico Transitório , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Humanos , Incidência , Pericardiocentese/efeitos adversos , Resultado do Tratamento
5.
Europace ; 19(6): 1038-1042, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27738058

RESUMO

AIMS: Cryoablation is an alternative method to radiofrequency ablation for treatment of atrioventricular nodal re-entrant tachycardia (AVNRT). This study investigates the long-term safety and efficacy of cryoablation in AVNRT. METHODS AND RESULTS: We studied 515 consecutive patients (317 women, mean age 50 years, range 13-89 years) undergoing a first cryoablation for AVNRT between 2003 and 2008. Ablations were performed with a 6-mm Freezor Xtra catheter. Six patients were acute failures; 494 out of 509 (97%) primarily successfully ablated patients were followed up for a mean of 7.1 years (range 2-12 years). About 11% (54/494 patients) of patients had recurrences of the index arrhythmia. Time to recurrence varied from days to 9 years; 14 patients (3%) had recurrences later than 2 years, 8 patients (2%) later than 3 years, and 6 patients (2%) later than 4 years. Recurrence rate was higher in patients with slow-slow or fast-slow AVNRT (n = 24) compared with the common slow-fast variant (25 vs. 10%; P = 0.04). Recurrence rate was not higher in patients with residual slow pathway conduction (jump with or without echo beat, n = 199, 39%). Transient atrioventricular (AV) block of the first-, second-, or third-degree during ablation was observed in 45 patients but had no impact on the risk of AVNRT recurrence. No late AV block occurred. Single vs. multiple applications or total amount of cryoenergy delivered did not differ between patients with and without recurrences. CONCLUSION: Cryoablation in AVNRT is safe with a long-term efficacy of 88%; however, very late recurrences occur.


Assuntos
Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Potenciais de Ação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/etiologia , Criança , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
Europace ; 19(12): 2023-2026, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28340160

RESUMO

AIMS: The transseptal approach is used for left atrial access during the ablation of atrial fibrillation (AF) and other left-sided arrhythmia substrates. Transseptal puncture (TP) is commonly performed with fluoroscopic guidance, contrast injection, and pressure monitoring. In many centres, additional techniques [intracardiac echocardiography (ICE), transoesophageal echocardiography (TEE), radiofrequency needle] are used to facilitate TP but its use adds costs. In this retrospective study, we studied the safety and complication rate when TP was routinely done with fluoroscopic guidance, contrast injection, and pressure monitoring using ICE or TEE only in selected cases. METHODS AND RESULTS: This study analysed 4690 consecutive TP performed between 2000 and 2015: 3408 (72.6%) were ablation of AF, left-sided atrial flutter, or left-sided atrial tachycardia (non-AP group); 1153 (24.6%) were ablation of left-sided accessory pathway, AP group; and 129 (2.8%) were ablation of ventricular tachycardia. Transseptal puncture was done under fluoroscopy, pressure monitoring, and commonly using contrast media injection. In 27 procedures, ICE or TEE was used to guide the TP. We found 34 tamponades (Tx) that required pericardial drainage of which 28 (0.59%) could possibly be TP related and six could not. The total complication rate for all Tx was 0.72%. A higher rate of tamponades was observed in the AF (non-AP) group than in the AP group (0.88 vs. 0.17%, P < 0.02). The highest rate of tamponades was registered during the operators 51-100 cases, 1.3%, and decreased to 0.4% in cases 101-200, P = 0.04. CONCLUSION: TP can safely be done under fluoroscopy and pressure monitoring without routine use of additional techniques. With experience, operators should be able to further decrease complication rate.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Septos Cardíacos/cirurgia , Radiografia Intervencionista , Taquicardia Supraventricular/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/terapia , Ablação por Cateter/efeitos adversos , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Ecocardiografia Transesofagiana , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Punções , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
7.
Scand Cardiovasc J ; 51(2): 69-73, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27826985

RESUMO

OBJECTIVES: Cryoablation (CRYO) is an alternative to radiofrequency (RF) for catheter ablation of cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL). We aimed to study whether different CTI morphologies had different impacts on procedural success for CRYO and RF. DESIGN: This study randomized 153 patients with CTI-dependent AFL (median age 65 years; range 34-82) to RF or CRYO (78 CRYO; 75 RF). Biplane angiography (RAO 30° and LAO 60°) was done before the ablation procedure and isthmuses were classified as straight (n = 81), concave (n = 43) or pouch-like (n = 29). RF was performed with a 3.5-mm open-irrigated tip catheter and CRYO was performed with a 9 F, 8-mm tip catheter. The ablation endpoint was bidirectional block of CTI. RESULTS: Acute procedural success was achieved in 70/75 patients in the RF group and in 72/78 patients in the CRYO group. With regard to CRYO or RF, acute procedural success rates were similar between the three isthmus types: straight: CRYO (92%) and RF (96%); concave: CRYO (92%) and RF (94%); and pouch-like: CRYO (94%) and RF (85%). There were no significant differences regarding success rate between the different morphologies in the CRYO or the RF group. The CTI was longer in patients with acute failure compared to the patients with acute success (38 ± 7 mm versus 33 ± 6 mm, p = 0.045). CONCLUSION: The CTI morphology did not influence the acute success rate for either the CRYO or the RF ablation of CTI-dependent AFL. A longer CTI was associated with a lower success rate regardless of energy source.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Sistema de Condução Cardíaco/cirurgia , Valva Tricúspide/cirurgia , Veias Cavas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Angiografia Coronária , Criocirurgia/efeitos adversos , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Método Simples-Cego , Suécia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Veias Cavas/diagnóstico por imagem , Veias Cavas/fisiopatologia
8.
J Cardiovasc Electrophysiol ; 25(9): 948-952, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24698206

RESUMO

BACKGROUND: Postablation atrial tachycardia (AT) is a significant complication following radiofrequency (RF) pulmonary vein isolation (PVI). Cryoballoon (CB) ablation is an alternative technique for PVI that appears to have a low incidence of AT. No direct comparison between AT risk in RF and CB ablation has been made. OBJECTIVE: To compare the incidence and characteristics of ATs after PVI with RF and with CB ablation in patients with paroxysmal atrial fibrillation (AF). METHODS: All patients who underwent their first PVI between January 2006 and September 2012 using either RF or CB ablation were included. When a repeat ablation procedure for AT was performed, the arrhythmia was classified as typical cavotricuspid isthmus (CTI) flutter or left atrial tachycardia (LA-AT) based on invasive mapping procedure findings and ECG P-wave morphology. RESULTS: The study population consisted of 415 and 215 consecutive patients in the RF and CB groups, respectively. After a mean follow-up of 38 ± 21 months, 52 (8.3%) patients presented ATs (9.4% and 6% in the RF and CB groups, respectively; P = 0.15). Of those, 26 (4.1%) were classified as LA-AT with 20 (4.8%) in the RF group and 6 (2.8%) in the CB group (P = 0.23). In patients without a history of typical CTI flutter or CTI line (n = 458), the incidence for this type of arrhythmia during follow-up was 3.5%. CONCLUSION: In patients with paroxysmal AF undergoing either RF or CB PVI as the sole ablation strategy, the incidence of postprocedural AT was low and there was no significant difference between the 2 techniques.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/etiologia , Estudos de Coortes , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Europace ; 16(2): 271-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23851515

RESUMO

AIMS: Radiofrequency (RF) ablation is effective for ablation of atrial arrhythmias. However, RF ablation in the vicinity of the atrioventricular (AV) node is associated with a risk of inadvertent, irreversible high-grade AV block, depending on the type of substrate. Cryoablation is an alternative method. The objective was to investigate the acute and long-term risks of AV block during cryoablation. METHODS AND RESULTS: We studied 1303 consecutive cryoablations of substrates in the vicinity of the AV node in 1201 patients (median age 51 years, range 6-89 years) on acute and long-term impairment to the AV nodal conduction system. The arrhythmias treated were AV nodal reentrant tachycardias (n=1116), paraseptal and superoparaseptal accessory pathways (n=100), and focal atrial tachycardias (n=87). In 158 (12%) procedures, cryomapping (38 cases) or cryoablation (120 cases) were stopped due to transient AV block (first-degree AV block 74 cases, second-degree AV block 67 cases, and third-degree AV block 17 cases) after which another site was tested. Transient AV block occurred within seconds of mapping up to 3 min of ablation. The incidence of AV block was similar for different substrates. In most cases, AV nodal conduction was restored within seconds but in two cases transient AV block lasted 21 and 45 min, respectively. There were no cases of acute permanent AV blocks. No late AV blocks occurred during follow-up (mean 24 months, range 6-96 months). CONCLUSION: Cryoablation adjacent to the AV node carries a negligible risk of permanent AV block. Transient AV block during ablation is a benign finding.


Assuntos
Arritmias Cardíacas/cirurgia , Bloqueio Atrioventricular/etiologia , Nó Atrioventricular/fisiopatologia , Criocirurgia/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Criança , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
10.
Int J Occup Saf Ergon ; 20(1): 111-25, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24629873

RESUMO

OBJECTIVE: Construction is a hazardous occupation due to the unique nature of activities involved and the repetitiveness of several field behaviors. The aim of this methodological and theoretical review is to explore the empirical factors influencing unsafe behaviors and accidents on construction sites. METHODS: In this work, results and findings from 56 related previous studies were investigated. These studies were categorized based on their design, type, methods of data collection, analytical methods, variables, and key findings. A qualitative content analysis procedure was used to extract variables, themes, and factors. In addition, all studies were reviewed to determine the quality rating and to evaluate the strength of provided evidence. RESULTS: The content analysis identified 8 main categories: (a) society, (b) organization, (c) project management, (d) supervision, (e) contractor, (f) site condition, (g) work group, and (h) individual characteristics. The review highlighted the importance of more distal factors, e.g., society and organization, and project management, that may contribute to reducing the likelihood of unsafe behaviors and accidents through the promotion of site condition and individual features (as proximal factors). CONCLUSION: Further research is necessary to provide a better understanding of the links between unsafe behavior theories and empirical findings, challenge theoretical assumptions, develop new applied theories, and make stronger recommendations.


Assuntos
Acidentes de Trabalho/psicologia , Comportamento , Indústria da Construção/organização & administração , Local de Trabalho/psicologia , Acidentes de Trabalho/prevenção & controle , Atitude , Humanos , Capacitação em Serviço , Liderança , Saúde Ocupacional , Políticas , Gestão da Segurança/organização & administração , Fatores Socioeconômicos
11.
Heart ; 110(3): 163-169, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-37657914

RESUMO

OBJECTIVE: Catheter ablation of atrial fibrillation effectively reduces symptomatic burden. However, its long-term effect on mortality and stroke is unclear. We investigated if patients with atrial fibrillation who undergo catheter ablation have lower risk for all-cause mortality or stroke than patients who are managed medically. METHODS: We retrospectively included 5628 consecutive patients who underwent first-time catheter ablation for atrial fibrillation between 2008 and 2018 at three major Swedish electrophysiology units. Control individuals with an atrial fibrillation diagnosis but without previous stroke were selected from the Swedish National Patient Register, resulting in a control group of 48 676 patients. Propensity score matching was performed to produce two cohorts of equal size (n=3955) with similar baseline characteristics. The primary endpoint was a composite of all-cause mortality or stroke. RESULTS: Patients who underwent catheter ablation were healthier (mean CHA2DS2-VASc score 1.4±1.4 vs 1.6±1.5, p<0.001), had a higher median income (288 vs 212 1000 Swedish krona [KSEK]/year, p<0.001) and had more frequently received university education (45.1% vs 28.9%, p<0.001). Mean follow-up was 4.5±2.8 years. After propensity score matching, catheter ablation was associated with lower risk for the combined primary endpoint (HR 0.58, 95% CI 0.48 to 0.69). The result was mainly driven by a decrease in all-cause mortality (HR 0.51, 95% CI 0.41 to 0.63), with stroke reduction showing a trend in favour of catheter ablation (HR 0.75, 95% CI 0.53 to 1.07). CONCLUSIONS: Catheter ablation of atrial fibrillation was associated with a reduction in the primary endpoint of all-cause mortality or stroke. This result was driven by a marked reduction in all-cause mortality.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Fatores de Risco , Medição de Risco/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
12.
Europace ; 15(3): 420-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22927662

RESUMO

AIMS: Radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) is an effective treatment for atrial flutter (AFL). However, RF may injure cardiac structures such as the atrio-ventricular node or the right coronary artery and is usually painful. This prospective, randomized study compares cryoablation (Cryo) with RF ablation regarding efficacy, safety, and perceived pain. METHODS AND RESULTS: One-hundred and fifty-three patients (78 Cryo; 75 RF) with CTI-dependent AFL--median age 65 years (range 34-82), 140 men (91%)--were randomized to Cryo or RF. Primary endpoint was demonstration of long-term efficacy defined as no symptomatic recurrence of AFL at the 6-month follow-up. Radiofrequency ablation was performed with a 3.5 mm open-irrigated-tip catheter and Cryo with a 9 F, 8 mm tip catheter. Ablation endpoint was bidirectional CTI block. Pain was evaluated with a visual analogue scale (VAS; 0-10). The acute success rate was 92% for Cryo and 95% for RF (P = 0.58). Procedural time was longer in the Cryo group (152 ± 54 min) than the RF group (116 ± 41 min) (P < 0.001). Cryoablation was considerably less painful compared with RF (mean VAS-Cryo 0.7 ± 1.2 vs. VAS-RF 4.6 ± 2.0; P < 0.001). Success rate at 6-month follow-up was 93% (73 of 78) for Cryo and 97% (73 of 75) for RF (P = 0.86). No major adverse events occurred in any group. CONCLUSION: Cryoablation of isthmus-dependent AFL is not inferior to RF but with significantly less procedure-related pain.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Distribuição de Qui-Quadrado , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Intervalo Livre de Doença , Eletrocardiografia , Desenho de Equipamento , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Dor/diagnóstico , Dor/etiologia , Dor/prevenção & controle , Medição da Dor , Percepção da Dor , Estudos Prospectivos , Recidiva , Método Simples-Cego , Suécia , Fatores de Tempo , Resultado do Tratamento
13.
Scand Cardiovasc J ; 47(2): 109-13, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23098247

RESUMO

OBJECTIVES: In the context of catheter ablation of atrial fibrillation, oral anticoagulant therapy has been traditionally replaced by bridging with heparin during the periprocedural period. We wanted to study the feasibility and safety of continuous warfarin therapy compared to traditional bridging therapy. DESIGN: The complication rates were compared retrospectively in a consecutive patient series. In the bridging group, warfarin was discontinued three days and low molecular weight heparin started one day prior to the procedure. Warfarin was reinitiated one day after and low molecular weight heparin was continued until the therapeutic INR target was reached. Patients on continuous therapy received warfarin throughout the periprocedural period. All patients received unfractionated heparin during the procedure. RESULTS: Three thromboembolic cerebrovascular events (1.9%) occurred in the bridging group (n = 157) and seven (0.82%) in the warfarin group (n = 850) (p = 0.142). The number of cardiac tamponades was one (0.64%) and four (0.47%), respectively (p = 0.786). Total number of severe bleeding and thromboembolic complications was more common in the bridging group: 9 (5.7%) versus 22 (2.6%); p = 0.036. In multivariate analysis, female gender, advanced age, and bridging therapy predicted complications. CONCLUSIONS: Continuous oral anticoagulant therapy is a safe and feasible alternative for bridging therapy in patients undergoing catheter ablation of atrial fibrillation.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Heparina/uso terapêutico , Varfarina/uso terapêutico , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Tamponamento Cardíaco/etiologia , Estudos de Viabilidade , Feminino , Heparina/administração & dosagem , Heparina/efeitos adversos , Humanos , Trombose Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Varfarina/administração & dosagem , Varfarina/efeitos adversos
14.
J Interv Card Electrophysiol ; 66(3): 577-584, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36085243

RESUMO

BACKGROUND: To study the association between timing and success of electrical cardioversion (ECV) for the treatment of early recurrences (ERs) of atrial fibrillation post pulmonary vein isolation (PVI) on long-term rhythm outcome. METHODS: Data of 133 patients ablated for paroxysmal or persistent atrial fibrillation receiving ECV for ERs, i.e., atrial tachyarrhythmia recurrences within 90 days post ablation were analyzed. During 1-year follow-up, patients were screened for late recurrences (LRs), i.e., recurrences after the blanking period. RESULTS: In 114 patients (85.7%), ECV was successful compared to 19 patients (14.3%) with failed ECV. A higher body mass index (odds ratio (OR) 1.19 (95% CI 1.02-1.39), p = 0.029), a lower left ventricular ejection fraction (OR 1.07 (95% CI 0.99-1.15), p = 0.079), and performance of ECV > 7 days from ER onset (OR 2.99 (95% CI 1.01-8.87), p = 0.048) remained independently associated with ECV failure. During 1-year follow-up, the rate of LR was significantly higher among patients with failed ECV as compared to patients with successful ECV (hazard ratio (HR) 3.00 (95% CI, 1.79-5.03), p < 0.001). Patients with ECV performed > 7 days from ER onset had a significantly higher risk of developing LR as compared to patients with ECV performed within ≤ 7 days from ER onset (HR 1.73 (95% CI 1.15-2.62), p = 0.009). Performance of ECV > 7 days from ER onset (HR 1.76 (95% CI 1.16-2.67), p = 0.008) and failed ECV (HR 3.32 (95% CI 1.96-5.64), p < 0.001) remained independently associated with LR. CONCLUSIONS: A failed ECV and performance of ECV > 7 days from ER onset were independently associated with LR.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Cardioversão Elétrica/efeitos adversos , Veias Pulmonares/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Recidiva , Resultado do Tratamento
15.
JACC Case Rep ; 4(11): 685-687, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35677791

RESUMO

A pulmonary vein isolation procedure in a patient with an atrial septal defect (ASD) closure device was complicated by entrapment of a mapping catheter in the device. The procedure was converted to open heart surgery, the device with the trapped catheter was explanted, the ASD was covered with a bovine patch, and a cryomaze procedure was performed. (Level of Difficulty: Intermediate.).

16.
Ann Noninvasive Electrocardiol ; 16(4): 327-35, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22008487

RESUMO

OBJECTIVE: To establish the diagnostic accuracy of the transesophageal ventriculo-atrial (VA) interval in patients with paroxysmal supraventricular tachycardia (PSVT) and normal baseline electrocardiogram (ECG). METHODS: The transesophageal VA interval during tachycardia was recorded in 318 patients (age 45 ± 17 years, 58% female) with PSVT and a normal surface ECG between attacks. Subsequently, all patients underwent an ablation procedure establishing the correct tachycardia diagnosis. RESULTS: AV nodal reentrant tachycardia (AVNRT), AV reentrant tachycardia through a concealed accessory pathway (AVRT), and ectopic atrial tachycardia (EAT) were found in 213, 95, and 10 cases, respectively. Receiver operating characteristic curve analysis identified an optimal cutoff for a binary categorization of AVNRT versus AVRT/EAT at ≤80 ms (area under the curve 0.891). Owing to a biphasic distribution, AVNRT was very likely at VA intervals ≤90 ms with a sensitivity, specificity, and positive predictive value (PPV) of 87%, 91%, and 95%. In the range 91-160 ms the corresponding values for AVRT were 88%, 95%, and 88% (90%, 99%, and 98% in male patients). In the small group with VA intervals >160 ms (n = 29), the diagnosis was less clear (PPV of 67% for AVNRT). CONCLUSIONS: In patients with sudden onset regular tachycardia and a normal ECG during sinus rhythm, a transesophageal VA interval of ≤80 ms has the highest diagnostic accuracy to diagnose AVNRT versus AVRT/EAT. Overall, the biphasic distribution of VA intervals suggests considering AVNRT at 90 ms and below and AVRT between 91 and 160 ms (in particular in male patients) while the diagnosis is vague at VA intervals above 160 ms.


Assuntos
Eletrocardiografia , Taquicardia Supraventricular/diagnóstico , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Supraventricular/fisiopatologia
17.
Clin Res Cardiol ; 110(6): 851-860, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33184675

RESUMO

PURPOSE: Cather ablation is known to influence the autonomic nervous system. This study sought to investigate the association of sinus heart rate pre-/post-ablation and recurrences in patients with atrial fibrillation undergoing pulmonary vein isolation (PVI). METHODS: Between January 2012 and December 2017, data of 482 patients undergoing their first PVI were included. Sinus heart rate was recorded before (PRE), directly post-ablation (POST) and 3 months post-ablation (3 M). All patients were screened for atrial tachyarrhythmia recurrences during the one-year follow-up. RESULTS: In the total study cohort, the mean resting sinus heart rate at PRE [mean 57.9 bpm (95% CI 57.1-58.7 bpm)] increased by over 10 bpm to POST [mean 69.4 bpm (95% CI 68.5-70.3 bpm); p < 0.001] followed by a slight decrease at 3 M [mean 67.3 bpm (95% CI 66.4-68.2 bpm)] but still remaining higher compared to PRE (p < 0.001). This pattern was observed in patients with and without recurrences at POST and 3 M (both p < 0.001 compared to PRE). However, at 3 M the mean sinus heart rate was significantly lower in patients with compared to patients without recurrences (p = 0.031). In this regard, patients with a heart rate change < 11 bpm (PRE to 3 M) or, as an alternative parameter, patients with a heart rate < 60 bpm at 3 M had a significantly higher risk of recurrences compared to the remaining patients (Hazard ratio (HR) 1.82 (95% CI 1.32-2.49), p < 0.001 and HR 1.64 (95% CI 1.20-2.25), p = 0.002, respectively). CONCLUSION: Our study confirms the impact of PVI on cardiac autonomic function with a significant sinus heart rate increase post-ablation. Patients with a sinus heart rate change < 11 bpm (PRE to 3 M) are at higher risk for recurrences during one-year post-PVI.


Assuntos
Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Fibrilação Atrial/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
18.
Europace ; 12(7): 972-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20348552

RESUMO

AIMS: Radiofrequency (RF) catheter ablation in the septum close to the atrioventricular (AV) node or His bundle has an increased risk of irreversible complications. Cryothermal energy has the advantages of reversible cryomapping and increased catheter stability. This study evaluates the usefulness of cryoablation in superoparaseptal and septal accessory pathways (APs). METHODS AND RESULTS: Twenty-seven consecutive patients (16 men, 11 women, median age 29 years, range 15-65) underwent cryoablation for APs either located in the superoparaseptal (n=18) or septal (n=9) area. Cryomapping, using exclusively a 6 mm tip catheter, at -30 degrees C was performed before ablation with a goal temperature of -80 degrees C for 240 s. Acute success was achieved in 26 out of 27 patients (96%). Total procedure and fluoroscopy time was 163+/-61 and 30+/-22 min, respectively. During a follow-up for a mean of 996+/-511 days, seven patients (27%) had recurrences of arrhythmia. Five out of these seven underwent a second cryoablation with successful results, giving a total success rate of 89%. Two patients developed transient second degree AV block during cryoablation; however, no permanent AV block was observed. The recurrence rate was significantly higher in patients with procedure-related transient mechanical AP block (6/7; 86%) due to catheter trauma compared with those without mechanical block (5/20; 25%; P=0.006). CONCLUSION: Cryoablation of the superoparaseptal and septal APs is a safe and effective alternative to RF therapy. Procedure-related transient mechanical AP block predicts worse late outcome.


Assuntos
Arritmias Cardíacas/cirurgia , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Defeitos dos Septos Cardíacos/cirurgia , Septos Cardíacos/cirurgia , Adolescente , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
19.
Anatol J Cardiol ; 24(6): 405-409, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33253134

RESUMO

OBJECTIVE: The preferential sites for focal atrial tachycardia (FAT) are mainly in the right atrium in both sexes. However, a limited number of studies have indicated that sex differences in the localization of FAT. This study investigated possible sex differences in the distribution of FAT in a large cohort of patients referred for ablation. METHODS: From 2004 to 2019, 487 patients (298 women) were referred to our institution for ablation of FAT. A standard electrophysiological study was conducted, and isoproterenol or atropine was given when needed. Conventional catheter mapping, electroanatomic contact mapping, and noncontact mapping were used to assess the origin of ectopic atrial tachycardia. RESULTS: Overall, 451 foci were successfully ablated in 436 patients (90%). Although the foci located along the crista terminalis were more common in women than in men (42% vs. 29%; p=0.023), the opposite were found in the foci located along the tricuspid annulus (5% vs. 11%; p=0.032) and the right atrial appendage (RAA) (1% vs. 3%; p=0.032). Other locations were similarly distributed in men and women. In addition, the presence of persistent FAT was more frequent in men than in women (22% vs. 5%; p<0.001). Finally, the difference in the induction pattern of FAT was also remarkable between sexes. CONCLUSION: The distribution of FAT in women and men is different. In addition, persistent FAT seems more often in men than in women. The different distribution, persistency, and induction pattern of FAT should be considered in the successful management of this type of tachycardia.


Assuntos
Taquicardia Atrial Ectópica/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores Sexuais , Suécia/epidemiologia , Taquicardia Atrial Ectópica/etiologia , Taquicardia Atrial Ectópica/cirurgia , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA