Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Hum Psychopharmacol ; 39(1): e2887, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38059650

RESUMO

INTRODUCTION: Relationships between inflammation and mood have been observed in terms of pro-inflammatory effects induced by depressive conditions and, in parallel, by an antidepressant-induced favorable effect on the recovery of inflammatory states. Selective serotonin reuptake inhibitor (SSRI) drugs were hypothesized to improve the prognosis of COVID-19 pneumonia, a typical acute inflammation, in terms of decreased mortality rate and pro-inflammatory cytokine serum levels. METHODS: The medical records of COVID-19 pneumonia inpatients at Careggi University Hospital (Florence) were analyzed for prognosis and Interleukin 6 (IL-6) after admission for over a period of 22 months. Medical records of patients treated at admission and not discontinued until discharge with an SSRI or with vortioxetine were identified. Two groups, one treated with antidepressants, the other not treated, were evaluated according to the mentioned parameters. Multiple linear regression and logistic regression were performed. RESULTS: The entire sample composed of 1236 records (recovered patients 77.1%, deceased patients 22.9%). The treated group (n = 107) had a better prognosis than the untreated group in spite of age and comorbidity both being greater than in the untreated group. Correspondingly, IL-6 levels in the treated group were significantly lower (p < 0.01) than the levels in the untreated group, in every comparison. CONCLUSIONS: Outcomes of this study support the hypothesis of the favorable influence of some antidepressants on the prognosis of COVID-19, possibly mediated by IL-6 modulation. Reduction in acute inflammation induced by the action of antidepressants was confirmed.


Assuntos
COVID-19 , Inibidores Seletivos de Recaptação de Serotonina , Humanos , Inibidores Seletivos de Recaptação de Serotonina/uso terapêutico , Estudos Retrospectivos , Interleucina-6 , Antidepressivos/uso terapêutico , Inflamação/tratamento farmacológico
2.
J Sleep Res ; 30(6): e13346, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33837981

RESUMO

Consumer "Smartbands" can collect physiological parameters, such as heart rate (HR), continuously across the sleep-wake cycle. Nevertheless, the quality of HR data detected by such devices and their place in the research and clinical field is debatable, as they are rarely rigorously validated. The objective of the present study was to investigate the reliability of pulse photoplethysmographic detection by the Fitbit ChargeHR™ (FBCHR, Fitbit Inc.) in a natural setting of continuous recording across vigilance states. To fulfil this aim, concurrent portable polysomnographic (pPSG) and the Fitbit's photoplethysmographic data were collected from a group of 25 healthy young adults, for ≥12 hr. The pPSG-derived HR was automatically computed and visually verified for each 1-min epoch, while the FBCHR HR measurements were downloaded from the application programming interface provided by the manufacturer. The FBCHR was generally accurate in estimating the HR, with a mean (SD) difference of -0.66 (0.04) beats/min (bpm) versus the pPSG-derived HR reference, and an overall Pearson's correlation coefficient (r) of 0.93 (average per participant r = 0.85 ± 0.11), regardless of vigilance state. The correlation coefficients were larger during all sleep phases (rapid eye movement, r = 0.9662; N1, r = 0.9918; N2, r = 0.9793; N3, r = 0.9849) than in wakefulness (r = 0.8432). Moreover, the correlation coefficient was lower for HRs of >100 bpm (r = 0.374) than for HRs of <100 bpm (r = 0.84). Consistently, Bland-Altman analysis supports the overall higher accuracy in the detection of HR during sleep. The relatively high accuracy of FBCHR pulse rate detection during sleep makes this device suitable for sleep-related research applications in healthy participants, under free-living conditions.


Assuntos
Monitores de Aptidão Física , Sono , Frequência Cardíaca , Humanos , Polissonografia , Reprodutibilidade dos Testes , Adulto Jovem
3.
Inorg Chem ; 59(10): 7274-7282, 2020 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-32343896

RESUMO

The photoionization dynamics of OsO4 and RuO4, chosen as model systems of small-size mononuclear heavy-metal complexes, has been theoretically studied by the time-dependent density functional theory (TDDFT). Accurate experimental measurements of photoionization dynamics as a benchmarking test for the theory are reported for the photoelectron asymmetry parameters of outer valence ionizations of OsO4, measured in the 17-90 eV photon energy range. The theoretical results are in good agreement with the available experimental data. The observed dynamical behavior of partial cross sections and asymmetry parameters has been related to both the coupling to the continuum of discrete excited states, giving strong modulations in the photon energy dependency, and the atomic composition of the initial ionized states, which determines the rate of decay of ionization probability for increasing excitation energies. Overall, an extensive analysis of the photoionization dynamics for valence and core orbitals is presented, showing good agreement with all the available experimental data. This provides confidence for the validity of the TDDFT approach in describing photoionization of heavy transition element compounds, with the perspective of being used for larger systems. Further experimental work is suggested for RuO4 to gather evidence of the sensitivity of the theoretical method to the nature of the metal atom.

4.
J Synchrotron Radiat ; 24(Pt 4): 750-756, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28664881

RESUMO

Complete photoemission experiments, enabling measurement of the full quantum set of the photoelectron final state, are in high demand for studying materials and nanostructures whose properties are determined by strong electron and spin correlations. Here the implementation of the new spin polarimeter VESPA (Very Efficient Spin Polarization Analysis) at the APE-NFFA beamline at Elettra is reported, which is based on the exchange coupling between the photoelectron spin and a ferromagnetic surface in a reflectometry setup. The system was designed to be integrated with a dedicated Scienta-Omicron DA30 electron energy analyzer allowing for two simultaneous reflectometry measurements, along perpendicular axes, that, after magnetization switching of the two targets, allow the three-dimensional vectorial reconstruction of the spin polarization to be performed while operating the DA30 in high-resolution mode. VESPA represents the very first installation for spin-resolved ARPES (SPARPES) at the Elettra synchrotron in Trieste, and is being heavily exploited by SPARPES users since autumn 2015.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38063066

RESUMO

AIM: Aberrant salience (AS) and psychotic-like experiences (PLEs) have been proven to be linked. Moreover, anxiety is a key symptom in psychosis-prone subjects and most psychotic patients. We propose a model that attempts to interpret the role of PLEs in the association between AS and anxiety among healthy controls and psychotic patients. METHODS: Demographic and psychometric data (Aberrant Salience Inventory, Community Assessment of Psychic Experiences, Symptom Check List-90-revised) from 163 controls and 44 psychotic patients was collected. Descriptive statistics, correlations, a linear regression model and a mediation analysis with covariates were subsequently performed. RESULTS: AS correlated with more frequent positive PLEs and higher anxiety levels in both patients and controls. However, positive PLEs' frequency mediated the relationship between AS and anxiety only among controls. CONCLUSIONS: PLEs linked to AS appear to induce anxiety among the control group but not among psychotic patients. The progressive loss of both novelty and insight, which may, respectively, impair the somatic emotional reactivity to PLEs and the ability to recognize some bodily phenomena as the embodied correlates of anxiety, is seen as the most probable theoretical explanation.

6.
J Biol Rhythms ; 38(2): 185-196, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36680409

RESUMO

Adolescents' conflict between circadian rhythm and early school start time is more pronounced in evening chronotypes, who tend to reduce sleep duration during school days compensating during the free days by oversleeping (i.e., social jetlag). Cumulative weekly sleep debt may impair sport performance, which relies on physical and cognitive skills modulated by sleep. We hypothesized that chronotype predicts sport performance, and that it may interact with the day of the week. Moreover, given the role sleep plays in motor memory consolidation, we tested the hypothesis that school attendance, and the related chronic sleep deprivation, might be detrimental for participants in a training phase. Ninety-three adolescent male basketball players performed multiple free throw sessions (n = 7880) during both the school and holiday periods. Chronotype and its interaction with the day of the week significantly predicted shooting accuracy when attending school, but not on holidays. Evening types' performance gradually decreased from Monday to Friday. Participants with a more unstable performance (i.e., who did not complete the acquisition of the free throw motor scheme) worsened their accuracy when attending school. Our results suggest that the impact of chronotype and day of the week on sport performance is related to the presence of an externally imposed sleep/wake schedule and is consistent with evening types' increased likelihood of experiencing social jetlag. Possibly due to early school start time, attending school worsened the performance of participants in a training phase. Further investigations are required to assess whether reducing the mismatch between biological and social clocks might improve sport performance, along with other aspects of adolescents' life.


Assuntos
Basquetebol , Ritmo Circadiano , Humanos , Masculino , Adolescente , Cronotipo , Sono , Síndrome do Jet Lag , Instituições Acadêmicas , Inquéritos e Questionários
7.
Sleep Health ; 9(6): 910-924, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37709595

RESUMO

GOAL AND AIMS: To evaluate an automatic sleep scoring algorithm against manual polysomnography sleep scoring. FOCUS METHOD/TECHNOLOGY: Yet Another Spindle Algorithm automatic sleep staging algorithm. REFERENCE METHOD/TECHNOLOGY: Manual sleep scoring. SAMPLE: 327 nights (151 healthy adolescents), from the NCANDA study. DESIGN: Participants underwent one-to-three overnight polysomnography recordings, one consisting of an event-related-potential paradigm. CORE ANALYTICS: Epoch by Epoch and discrepancy analyses (Bland Altman plots) were conducted on the overall sample. ADDITIONAL ANALYTICS AND EXPLORATORY ANALYSES: Epoch by Epoch and discrepancy analysis were repeated separately on standard polysomnography nights and event-related potential nights. Regression models were estimated on age, sex, scorer, and site of recording, separately on standard polysomnography nights and event-related potential nights. CORE OUTCOMES: The Yet Another Spindle Algorithm sleep scoring algorithm's average sensitivity of 93.04% for Wake, 87.67% for N2, 84.46% for N3, 86.02% for rapid-eye-movement, and 40.39% for N1. Specificity was 96.75% for Wake, 97.31% for N1, 88.87% for N2, 97.99% for N3, and 97.70% for rapid-eye-movement. The Matthews Correlation Coefficient was highest in rapid-eye-movement sleep (0.85) while lowest in N1 (0.39). Cohen's Kappa mirrored Matthews Correlation Coefficient results. In Bland-Altman plots, the bias between Yet Another Spindle Algorithm and human scoring showed proportionality to the manual scoring measurement size. IMPORTANT ADDITIONAL OUTCOMES: Yet Another Spindle Algorithm performance was reduced in event-related-potential/polysomnography nights for N3 and rapid-eye-movement. According to the Matthews Correlation Coefficient, the Yet Another Spindle Algorithm performance was affected by younger age, male sex, recording sites, and scorers. CORE CONCLUSION: Results support the use of Yet Another Spindle Algorithm to score adolescents' polysomnography sleep records, possibly with classification outcomes supervised by an expert scorer.


Assuntos
Fases do Sono , Sono , Humanos , Masculino , Adolescente , Reprodutibilidade dos Testes , Polissonografia/métodos , Algoritmos
8.
Nat Sci Sleep ; 14: 941-956, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35611177

RESUMO

Purpose: A large portion of the adult population is thought to suffer from obstructive sleep apnoea syndrome (OSAS), a sleep-related breathing disorder associated with increased morbidity and mortality. International guidelines include the polysomnography and the cardiorespiratory monitoring (CRM) as diagnostic tools for OSAS, but they are unfit for a large-scale screening, given their invasiveness, high cost and lengthy process of scoring. Current screening methods are based on self-reported questionnaires that suffer from lack of objectivity. On the contrary, commercial smartbands are wearable devices capable of collecting accelerometric and photoplethysmographic data in a user-friendly and objective way. We questioned whether machine-learning (ML) classifiers trained on data collected through these wearable devices would help predict OSAS severity. Patients and Methods: Each of the patients (n = 78, mean age ± SD: 57.2 ± 12.9 years; 30 females) underwent CRM and concurrently wore a commercial wrist smartband. CRM's traces were scored, and OSAS severity was reported as apnoea hypopnoea index (AHI). We trained three pairs of classifiers to make the following prediction: AHI <5 vs AHI ≥5, AHI <15 vs AHI ≥15, and AHI <30 vs AHI ≥30. Results: According to the Matthews correlation coefficient (MCC), the proposed algorithms reached an overall good correlation with the ground truth (CRM) for AHI <5 vs AHI ≥5 (MCC: 0.4) and AHI <30 vs AHI ≥30 (MCC: 0.3) classifications. AHI <5 vs AHI ≥5 and AHI <30 vs AHI ≥30 classifiers' sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV) and diagnostic odds ratio (DOR) are comparable with the STOP-Bang questionnaire, an established OSAS screening tool. Conclusion: Machine learning algorithms showed an overall good performance. Unlike questionnaires, these are based on objectively collected data. Furthermore, these commercial devices are widely distributed in the general population. The aforementioned advantages of machine-learning algorithms applied to smartbands' data over questionnaires lead to the conclusion that they could serve a population-scale screening for OSAS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA