1.
Opt Express ; 21(10): 12385-94, 2013 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-23736456

RESUMO

Characterizing intense, focused x-ray free electron laser (FEL) pulses is crucial for their use in diffractive imaging. We describe how the distribution of average phase tilts and intensities on hard x-ray pulses with peak intensities of 10(21) W/m(2) can be retrieved from an ensemble of diffraction patterns produced by 70 nm-radius polystyrene spheres, in a manner that mimics wavefront sensors. Besides showing that an adaptive geometric correction may be necessary for diffraction data from randomly injected sample sources, our paper demonstrates the possibility of collecting statistics on structured pulses using only the diffraction patterns they generate and highlights the imperative to study its impact on single-particle diffractive imaging.


Assuntos
Aerossóis/análise , Aerossóis/química , Lasers , Fotometria/métodos , Refratometria/métodos , Ressonância de Plasmônio de Superfície/métodos , Raios X , Elétrons , Desenho de Equipamento , Análise de Falha de Equipamento , Microesferas
2.
Opt Express ; 21(23): 28729-42, 2013 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-24514385

RESUMO

Single shot diffraction imaging experiments via X-ray free-electron lasers can generate as many as hundreds of thousands of diffraction patterns of scattering objects. Recovering the real space contrast of a scattering object from these patterns currently requires a reconstruction process with user guidance in a number of steps, introducing severe bottlenecks in data processing. We present a series of measures that replace user guidance with algorithms that reconstruct contrasts in an unsupervised fashion. We demonstrate the feasibility of automating the reconstruction process by generating hundreds of contrasts obtained from soot particle diffraction experiments.

3.
Nature ; 448(7154): 676-9, 2007 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-17687320

RESUMO

Extremely intense and ultrafast X-ray pulses from free-electron lasers offer unique opportunities to study fundamental aspects of complex transient phenomena in materials. Ultrafast time-resolved methods usually require highly synchronized pulses to initiate a transition and then probe it after a precisely defined time delay. In the X-ray regime, these methods are challenging because they require complex optical systems and diagnostics. Here we propose and apply a simple holographic measurement scheme, inspired by Newton's 'dusty mirror' experiment, to monitor the X-ray-induced explosion of microscopic objects. The sample is placed near an X-ray mirror; after the pulse traverses the sample, triggering the reaction, it is reflected back onto the sample by the mirror to probe this reaction. The delay is encoded in the resulting diffraction pattern to an accuracy of one femtosecond, and the structural change is holographically recorded with high resolution. We apply the technique to monitor the dynamics of polystyrene spheres in intense free-electron-laser pulses, and observe an explosion occurring well after the initial pulse. Our results support the notion that X-ray flash imaging can be used to achieve high resolution, beyond radiation damage limits for biological samples. With upcoming ultrafast X-ray sources we will be able to explore the three-dimensional dynamics of materials at the timescale of atomic motion.


Assuntos
Holografia/métodos , Poliestirenos/química , Raios X , Elétrons , Lasers , Microesferas , Fatores de Tempo
4.
Anal Chem ; 84(5): 2498-504, 2012 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-22283555

RESUMO

FITC-albumin, Lsr-F, or fluorescent polystyrene latex particles were electrosprayed from aqueous buffer and subjected to dispersion by differential electrical mobility at atmospheric pressure. A resulting narrow size cut of singly charged molecular ions or particles was passed through a condensation growth tube collector to create a flow stream of small water droplets, each carrying a single ion or particle. The droplets were splash landed (impacted) onto a solid or liquid temperature controlled surface. Small pools of droplets containing size-selected particles, FITC-albumin, or Lsr-F were recovered, re-electrosprayed, and, when analyzed a second time by differential electrical mobility, showed increased homogeneity. Transmission electron microscopy (TEM) analysis of the size-selected Lsr-F sample corroborated the mobility observation.


Assuntos
Fluoresceína-5-Isotiocianato/análogos & derivados , Microscopia Eletrônica de Transmissão , Nanopartículas/química , Albumina Sérica/química , Fluoresceína-5-Isotiocianato/química , Tamanho da Partícula , Poliestirenos/química , Propriedades de Superfície , Temperatura
5.
MAbs ; 14(1): 2135183, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36284469

RESUMO

Detection of host cell protein (HCP) impurities is critical to ensuring that recombinant drug products, including monoclonal antibodies (mAbs), are safe. Mechanistic characterization as to how HCPs persist in drug products is important to refining downstream processing. It has been hypothesized that weak lipase-mAb interactions enable HCP lipases to evade drug purification processes. Here, we apply state-of-the-art methods to establish lipase-mAb binding mechanisms. First, the mass spectrometry (MS) approach of fast photochemical oxidation of proteins was used to elucidate putative binding regions. The CH1 domain was identified as a conserved interaction site for IgG1 and IgG4 mAbs against the HCPs phospholipase B-like protein (PLBL2) and lysosomal phospholipase A2 (LPLA2). Rationally designed mutations in the CH1 domain of the IgG4 mAb caused a 3- to 70-fold KD reduction against PLBL2 by surface plasmon resonance (SPR). LPLA2-IgG4 mutant complexes, undetected by SPR and studied using native MS collisional dissociation experiments, also showed significant complex disruption, from 16% to 100%. Native MS and ion mobility (IM) determined complex stoichiometries for four lipase-IgG4 complexes and directly interrogated the enrichment of specific lipase glycoforms. Confirmed with time-course and exoglycosidase experiments, deglycosylated lipases prevented binding, and low-molecular-weight glycoforms promoted binding, to mAbs. This work demonstrates the value of integrated biophysical approaches to characterize micromolar affinity complexes. It is the first in-depth structural report of lipase-mAb binding, finding roles for the CH1 domain and lipase glycosylation in mediating binding. The structural insights gained offer new approaches for the bioengineering of cells or mAbs to reduce HCP impurity levels.Abbreviations: CAN, Acetonitrile; AMAC, Ammonium acetate; BFGS, Broyden-Fletcher-Goldfarb-Shanno; CHO, Chinese Hamster Ovary; KD, Dissociation constant; DTT, Dithiothreitol; ELISA, Enzyme-linked immunosorbent assay; FPOP, Fast photochemical oxidation of proteins; FA, Formic acid; F(ab'), Fragment antibodies; HCP, Host cell protein; IgG, Immunoglobulin; IM, Ion mobility; LOD, Lower limit of detection; LPLA2, Lysosomal phospholipase A2; Man, Mannose; MS, Mass spectrometry; MeOH, Methanol; MST, Microscale thermophoresis; mAbs, Monoclonal antibodies; PPT1, Palmitoyl protein thioesterase; ppm, Parts per million; PLBL2, Phospholipase B-like protein; PLD3, Phospholipase D3; PS-20, Polysorbate-20; SP, Sphingomyelin phosphodiesterase; SPR, Surface plasmon resonance; TFA, Trifluoroacetic acid.


Assuntos
Lisofosfolipase , Esfingomielina Fosfodiesterase , Humanos , Cricetinae , Animais , Cricetulus , Células CHO , Polissorbatos , Ditiotreitol , Manose , Ácido Trifluoracético , Metanol , Anticorpos Monoclonais/química , Imunoglobulina G/genética , Fosfolipases A2 , Acetonitrilas , Lipase , Glicosídeo Hidrolases
6.
Biochim Biophys Acta ; 1788(3): 724-31, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19109924

RESUMO

To better understand the incorporation of membrane proteins into discoidal nanolipoprotein particles (NLPs) we have used atomic force microscopy (AFM) to image and analyze NLPs assembled in the presence of bacteriorhodopsin (bR), lipoprotein E4 n-terminal 22k fragment scaffold and DMPC lipid. The self-assembly process produced two distinct NLP populations: those containing inserted bR (bR-NLPs) and those that did not (empty-NLPs). The bR-NLPs were distinguishable from empty-NLPs by an average increase in height of 1.0 nm as measured by AFM. Streptavidin binding to biotinylated bR confirmed that the original 1.0 nm height increase corresponds to br-NLP incorporation. AFM and ion mobility spectrometry (IMS) measurements suggest that NLP size did not vary around a single mean but instead there were several subpopulations, which were separated by discrete diameters. Interestingly, when bR was present during assembly the diameter distribution was shifted to larger particles and the larger particles had a greater likelihood of containing bR than smaller particles, suggesting that membrane proteins alter the mechanism of NLP assembly.


Assuntos
Bacteriorodopsinas/química , Lipoproteínas/metabolismo , Proteínas de Membrana/química , Proteínas de Membrana/metabolismo , Microscopia de Força Atômica , Nanoestruturas , Tamanho da Partícula , Espectrofotometria Ultravioleta
8.
Clin Chem ; 54(8): 1307-16, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18515257

RESUMO

BACKGROUND: Current methods for measuring the concentrations of lipoprotein particles and their distributions in particle subpopulations are not standardized. We describe here and validate a new gas-phase differential electrophoretic macromolecular mobility-based method (ion mobility, or IM) for direct quantification of lipoprotein particles, from small, dense HDL to large, buoyant, very-low-density lipoprotein (VLDL). METHODS: After an ultracentrifugation step to remove albumin, we determined the size and concentrations of lipoprotein particles in serum samples using IM. Scan time is 2 min and covers a particle range of 17.2-540.0 A. After scanning, data are pooled by totaling the particle number across a predetermined size range that corresponds to particular lipoprotein subclasses. IM results were correlated with those of standard methods for cholesterol and apolipoprotein analysis. RESULTS: Intra- and interassay coefficients of variation for LDL particle size were <1.0%. The intra- and interassay variation for LDL and HDL particle subfraction measurements was <20%. IM-measured non-HDL correlated well with apolipoprotein B (r = 0.92). CONCLUSIONS: The IM method provides accurate, reproducible, direct determination of size and concentration for a broad range of lipoprotein particles. Use of this methodology in studies of patients with cardiovascular disease and other pathologic states will permit testing of its clinical utility for risk assessment and management of these conditions.


Assuntos
Lipoproteínas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Feminino , Humanos , Lipoproteínas HDL/sangue , Lipoproteínas IDL/sangue , Lipoproteínas LDL/sangue , Lipoproteínas VLDL/sangue , Masculino , Tamanho da Partícula , Padrões de Referência , Reprodutibilidade dos Testes , Manejo de Espécimes , Espectrometria de Massas por Ionização por Electrospray/instrumentação
9.
IUCrJ ; 5(Pt 1): 103-117, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29354276

RESUMO

Previous proof-of-concept measurements on single-layer two-dimensional membrane-protein crystals performed at X-ray free-electron lasers (FELs) have demonstrated that the collection of meaningful diffraction patterns, which is not possible at synchrotrons because of radiation-damage issues, is feasible. Here, the results obtained from the analysis of a thousand single-shot, room-temperature X-ray FEL diffraction images from two-dimensional crystals of a bacteriorhodopsin mutant are reported in detail. The high redundancy in the measurements boosts the intensity signal-to-noise ratio, so that the values of the diffracted intensities can be reliably determined down to the detector-edge resolution of 4 Å. The results show that two-dimensional serial crystallography at X-ray FELs is a suitable method to study membrane proteins to near-atomic length scales at ambient temperature. The method presented here can be extended to pump-probe studies of optically triggered structural changes on submillisecond timescales in two-dimensional crystals, which allow functionally relevant large-scale motions that may be quenched in three-dimensional crystals.

10.
IUCrJ ; 4(Pt 3): 251-262, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28512572

RESUMO

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ∼40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ∼35 to ∼300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 1012 photons per µm2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. The results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

11.
Angew Chem Int Ed Engl ; 40(3): 541-544, 2001 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-29712014

RESUMO

The simultaneous measurement of the time-of-flight and the number of charges on each electrosprayed ion provides a new way to determine the mass of a whole intact virus. The weights of an icosahedral virus (rice yellow mottle virus) consisting of a single-stranded RNA surrounded by a homogeneous protein shell with a mass of 6.5×106 Da, and a rod-shaped RNA virus (tobacco mosaic virus) with a mass of 40.5×106 Da were measured with this technique.

12.
Sci Rep ; 4: 6026, 2014 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-25113598

RESUMO

We present results from experiments at the Linac Coherent Light Source (LCLS) demonstrating that serial femtosecond crystallography (SFX) can be performed to high resolution (~2.5 Å) using protein microcrystals deposited on an ultra-thin silicon nitride membrane and embedded in a preservation medium at room temperature. Data can be acquired at a high acquisition rate using x-ray free electron laser sources to overcome radiation damage, while sample consumption is dramatically reduced compared to flowing jet methods. We achieved a peak data acquisition rate of 10 Hz with a hit rate of ~38%, indicating that a complete data set could be acquired in about one 12-hour LCLS shift using the setup described here, or in even less time using hardware optimized for fixed target SFX. This demonstration opens the door to ultra low sample consumption SFX using the technique of diffraction-before-destruction on proteins that exist in only small quantities and/or do not produce the copious quantities of microcrystals required for flowing jet methods.


Assuntos
Cristalografia/métodos , Lasers , Proteínas/química , Cristalografia/instrumentação , Elétrons , Conformação Proteica
13.
IUCrJ ; 1(Pt 2): 95-100, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25075325

RESUMO

X-ray diffraction patterns from two-dimensional (2-D) protein crystals obtained using femtosecond X-ray pulses from an X-ray free-electron laser (XFEL) are presented. To date, it has not been possible to acquire transmission X-ray diffraction patterns from individual 2-D protein crystals due to radiation damage. However, the intense and ultrafast pulses generated by an XFEL permit a new method of collecting diffraction data before the sample is destroyed. Utilizing a diffract-before-destroy approach at the Linac Coherent Light Source, Bragg diffraction was acquired to better than 8.5 Šresolution for two different 2-D protein crystal samples each less than 10 nm thick and maintained at room temperature. These proof-of-principle results show promise for structural analysis of both soluble and membrane proteins arranged as 2-D crystals without requiring cryogenic conditions or the formation of three-dimensional crystals.

14.
Philos Trans R Soc Lond B Biol Sci ; 369(1647): 20130500, 2014 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-24914166

RESUMO

Membrane proteins arranged as two-dimensional crystals in the lipid environment provide close-to-physiological structural information, which is essential for understanding the molecular mechanisms of protein function. Previously, X-ray diffraction from individual two-dimensional crystals did not represent a suitable investigational tool because of radiation damage. The recent availability of ultrashort pulses from X-ray free-electron lasers (XFELs) has now provided a means to outrun the damage. Here, we report on measurements performed at the Linac Coherent Light Source XFEL on bacteriorhodopsin two-dimensional crystals mounted on a solid support and kept at room temperature. By merging data from about a dozen single crystal diffraction images, we unambiguously identified the diffraction peaks to a resolution of 7 Å, thus improving the observable resolution with respect to that achievable from a single pattern alone. This indicates that a larger dataset will allow for reliable quantification of peak intensities, and in turn a corresponding increase in the resolution. The presented results pave the way for further XFEL studies on two-dimensional crystals, which may include pump-probe experiments at subpicosecond time resolution.


Assuntos
Bacteriorodopsinas/química , Cristalografia por Raios X/métodos , Elétrons , Lasers , Difração de Raios X/métodos , Bacteriorodopsinas/ultraestrutura , Processamento de Imagem Assistida por Computador , Conformação Proteica
17.
18.
Nano Lett ; 8(1): 310-6, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18095739

RESUMO

In nanotechnology, strategies for the creation and manipulation of nanoparticles in the gas phase are critically important for surface modification and substrate-free characterization. Recent coherent diffractive imaging with intense femtosecond X-ray pulses has verified the capability of single-shot imaging of nanoscale objects at suboptical resolutions beyond the radiation-induced damage threshold. By intercepting electrospray-generated particles with a single 15 femtosecond soft-X-ray pulse, we demonstrate diffractive imaging of a nanoscale specimen in free flight for the first time, an important step toward imaging uncrystallized biomolecules.

19.
J Lipid Res ; 49(7): 1420-30, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18403317

RESUMO

Self-assembly of purified apolipoproteins and phospholipids results in the formation of nanometer-sized lipoprotein complexes, referred to as nanolipoprotein particles (NLPs). These bilayer constructs are fully soluble in aqueous environments and hold great promise as a model system to aid in solubilizing membrane proteins. Size variability in the self-assembly process has been recognized for some time, yet limited studies have been conducted to examine this phenomenon. Understanding the source of this heterogeneity may lead to methods to mitigate heterogeneity or to control NLP size, which may be important for tailoring NLPs for specific membrane proteins. Here, we have used atomic force microscopy, ion mobility spectrometry, and transmission electron microscopy to quantify NLP size distributions on the single-particle scale, specifically focusing on assemblies with 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) and a recombinant apolipoprotein E variant containing the N-terminal 22 kDa fragment (E422k). Four discrete sizes of E422k/DMPC NLPs were identified by all three techniques, with diameters centered at approximately 14.5, 19, 23.5, and 28 nm. Computer simulations suggest that these sizes are related to the structure and number of E422k lipoproteins surrounding the NLPs and particles with an odd number of lipoproteins are consistent with the double-belt model, in which at least one lipoprotein adopts a hairpin structure.


Assuntos
Lipoproteínas/química , Lipoproteínas/ultraestrutura , Nanopartículas/química , Nanopartículas/ultraestrutura , Biologia Computacional , Dimiristoilfosfatidilcolina/isolamento & purificação , Dimiristoilfosfatidilcolina/metabolismo , Eletroforese em Gel de Poliacrilamida , Lipoproteínas/isolamento & purificação , Lipoproteínas/metabolismo , Microscopia de Força Atômica , Microscopia Eletrônica de Transmissão , Modelos Moleculares , Dobramento de Proteína , Estrutura Terciária de Proteína
20.
J Proteome Res ; 5(3): 539-47, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16512668

RESUMO

Protein oxidation is linked to cellular stress, aging, and disease. Protein oxidations that result in reactive species are of particular interest, since these reactive oxidation products may react with other proteins or biomolecules in an unmediated and irreversible fashion, providing a potential marker for a variety of disease mechanisms. We have developed a novel system to identify and quantitate, relative to other states, the sites of oxidation on a given protein. This presents a significant advancement over current methods, combining strengths of current methods and adding the abilities to multiplex, quantitate, and probe more modified amino acids. A specially designed Oxidation-dependent carbonyl-specific Element-Coded Affinity Mass Tag (O-ECAT), AOD, ((S)-2-(4-(2-aminooxy)-acetamido)-benzyl)-1,4,7,10-tetraazacyclododecane-N,N',N' ',N'''-tetraacetic acid, is used to covalently tag the residues of a protein oxidized to aldehyde or keto end products. O-ECAT can be loaded with a variety of metals, which yields the ability to generate mass pairs and multiplex multiple samples. The O-ECAT moiety also serves as a handle for identification, quantitation, and affinity purification. After proteolysis, the AOD-tagged peptides are affinity purified and analyzed by nanoLC-FTICR-MS (nanoliquid chromatography-Fourier transform ion cyclotron resonance-mass spectrometry), which provides high specificity in extracting coeluting AOD mass pairs with a unique mass difference and allows relative quantitation based on isotopic ratios. Using this methodology, we have quantified and mapped the surface oxidation sites on a model protein, recombinant human serum albumin (rHSA) in its native form (as purchased) and after FeEDTA oxidation both at the protein and amino acid levels. A variety of modified amino acid residues including lysine, arginine, proline, histidine, threonine, aspartic, and glutamic acids, were found to be oxidized to aldehyde and keto end products. The sensitivity of this methodology is shown by the number of peptides identified, twenty peptides on the native protein and twenty-nine after surface oxidation using FeEDTA and ascorbate. All identified peptides map to the surface of the HSA crystal structure, validating this method for identifying oxidized amino acids on protein surfaces. In relative quantitation experiments between FeEDTA oxidation and native protein oxidation, identified sites showed different relative propensities toward oxidation, independent of amino acid residue. This novel methodology not only has the ability to identify and quantitate oxidized proteins but also yields site-specific quantitation on a variety of individual amino acids. We expect to extend this methodology to study disease-related oxidation.


Assuntos
Marcadores de Afinidade , Oxirredução , Proteínas/química , Proteínas/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier , Sequência de Aminoácidos , Cromatografia Líquida , Cristalização , Espectrometria de Massas , Dados de Sequência Molecular , Nanotecnologia/métodos , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Estrutura Terciária de Proteína