Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Biomed Inform ; 52: 279-92, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25038553

RESUMO

This paper describes the creation of a comprehensive conceptualization of object models used in medical image simulation, suitable for major imaging modalities and simulators. The goal is to create an application ontology that can be used to annotate the models in a repository integrated in the Virtual Imaging Platform (VIP), to facilitate their sharing and reuse. Annotations make the anatomical, physiological and pathophysiological content of the object models explicit. In such an interdisciplinary context we chose to rely on a common integration framework provided by a foundational ontology, that facilitates the consistent integration of the various modules extracted from several existing ontologies, i.e. FMA, PATO, MPATH, RadLex and ChEBI. Emphasis is put on methodology for achieving this extraction and integration. The most salient aspects of the ontology are presented, especially the organization in model layers, as well as its use to browse and query the model repository.


Assuntos
Diagnóstico por Imagem , Processamento de Imagem Assistida por Computador/métodos , Internet , Semântica , Vocabulário Controlado , Encéfalo/patologia , Simulação por Computador , Humanos , Modelos Teóricos , Software
2.
Stud Health Technol Inform ; 159: 203-14, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20543439

RESUMO

This paper studies the optimization of Mean-Shift (MS) image filtering scale parameters. A parameter sweep experiment representing 164 days of CPU is performed on the EGEE grid. The mathematical foundations of Mean-Shift and the grid environment used for the deployment are described in details. The experiments and results are then discussed highlighting the efficiency of gradient ascent algorithm for MS parameters optimization and a number of grid observations related to data transfers, reliability, task scheduling, CPU time and usability.


Assuntos
Redes de Comunicação de Computadores/organização & administração , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos
3.
Med Image Anal ; 58: 101551, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31499319

RESUMO

The advent of deep learning has pushed medical image analysis to new levels, rapidly replacing more traditional machine learning and computer vision pipelines. However segmenting and labelling anatomical regions remains challenging owing to appearance variations, imaging artifacts, the paucity and variability of annotated data, and the difficulty of fully exploiting domain constraints such as anatomical knowledge about inter-region relationships. We address the last point, improving the network's region-labeling consistency by introducing NonAdjLoss, an adjacency-graph based auxiliary training loss that penalizes outputs containing regions with anatomically-incorrect adjacency relationships. NonAdjLoss supports both fully-supervised training and a semi-supervised extension in which it is applied to unlabeled supplementary training data. The approach substantially reduces segmentation anomalies on the MICCAI-2012, IBSRv2 brain MRI datasets and the Anatomy3 whole body CT dataset, especially when semi-supervised training is included.


Assuntos
Mapeamento Encefálico/métodos , Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Aprendizado de Máquina Supervisionado , Tomografia Computadorizada por Raios X , Humanos
4.
Med Image Anal ; 10(2): 234-46, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16307900

RESUMO

Magnetic resonance imaging is a popular and powerful non-invasive imaging technique. Automated analysis has become mandatory to efficiently cope with the large amount of data generated using this modality. However, several artifacts, such as intensity non-uniformity, can degrade the quality of acquired data. Intensity non-uniformity consists in anatomically irrelevant intensity variation throughout data. It can be induced by the choice of the radio-frequency coil, the acquisition pulse sequence and by the nature and geometry of the sample itself. Numerous methods have been proposed to correct this artifact. In this paper, we propose an overview of existing methods. We first sort them according to their location in the acquisition/processing pipeline. Sorting is then refined based on the assumptions those methods rely on. Next, we present the validation protocols used to evaluate these different correction schemes both from a qualitative and a quantitative point of view. Finally, availability and usability of the presented methods is discussed.


Assuntos
Algoritmos , Artefatos , Inteligência Artificial , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
IEEE Trans Med Imaging ; 32(1): 110-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23014715

RESUMO

This paper presents the Virtual Imaging Platform (VIP), a platform accessible at http://vip.creatis.insa-lyon.fr to facilitate the sharing of object models and medical image simulators, and to provide access to distributed computing and storage resources. A complete overview is presented, describing the ontologies designed to share models in a common repository, the workflow template used to integrate simulators, and the tools and strategies used to exploit computing and storage resources. Simulation results obtained in four image modalities and with different models show that VIP is versatile and robust enough to support large simulations. The platform currently has 200 registered users who consumed 33 years of CPU time in 2011.


Assuntos
Sistemas de Gerenciamento de Base de Dados , Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Software , Simulação por Computador , Bases de Dados Factuais , Humanos , Aplicações da Informática Médica , Modelos Biológicos , Reprodutibilidade dos Testes
6.
Magn Reson Imaging ; 27(4): 577-85, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-18984068

RESUMO

Magnetic resonance imaging has proven its potential application in bread dough and gas cell monitoring studies, and dynamic processes such as dough proving and baking can be monitored. However, undesirable magnetic susceptibility effects often affect quantification studies, especially at high fields. A new low-field method is presented based on local assessment of porosity in spin-echo imaging, local characterization of signal loss in gradient-echo imaging and prediction of relaxation times by simulation to estimate bubble radii in bread dough during proving. Maps of radii showed different regions of dough constituting networks which evolved during proving. Mean radius and bubble distribution were assessed during proving.


Assuntos
Pão/análise , Farinha/análise , Análise de Alimentos/métodos , Gases/análise , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Humanos , Microesferas , Porosidade , Alvéolos Pulmonares/anatomia & histologia
7.
MAGMA ; 21(4): 261-71, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18575911

RESUMO

OBJECTIVE: Characterization of magnetic susceptibility artefacts with assessment of the gradient-echo signal decay function of echo time, pixel size, and object geometry in the case of air-filled cylinders embedded in water. MATERIALS AND METHODS: Experiments were performed with a 0.2 T magnet on a network of small interacting air-filled cylinders along with Magnetic resonance imaging (MRI) simulations integrating intravoxel dephasing. Signal decay over echo time was assessed at different pixel sizes on real and simulated images. The effects of radius, distance between cylinders and main magnetic field were studied using simulation. RESULTS: Signal loss was greater as echo time or pixel size increased. Voxel signal decay was not exponential but was weighted by sinus cardinalis functions integrating echo time, pixel size and field inhomogeneities which depended on main magnetic field strength and geometric configuration of the object. Simulation was able to model signal decay, even for a complex object constituted of several cylinders. The specific experimental signal modulation we observed was thus reproduced and explained by simulation. CONCLUSION: The quantitative signal decay approach at 0.2 T can be used in characterization studies in the case of locally regular air/water interfaces as the signal depends on object size relative to pixel size and is relevant to the geometric configuration. Moreover, the good concordance between simulation and experiments should lead to further studies of magnetic susceptibility effects with other objects such as networks of spheres. MRI simulation is thus a potential tool for molecular and porous media imaging.


Assuntos
Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Anisotropia , Artefatos , Interpretação de Imagem Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA