Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646922

RESUMO

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Esôfago , Traumatismos do Nervo Vago , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Masculino , Feminino , Esôfago/lesões , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Traumatismos do Nervo Vago/etiologia , Traumatismos do Nervo Vago/epidemiologia , Incidência , Idoso , Aprendizado de Máquina , Fatores de Risco , Alemanha/epidemiologia , Queimaduras/epidemiologia , Queimaduras/etiologia , Fatores de Tempo , Resultado do Tratamento , Veias Pulmonares/cirurgia , Nervo Vago
2.
J Cardiovasc Electrophysiol ; 34(2): 403-411, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36434796

RESUMO

BACKGROUND AND OBJECTIVE: Cardiac tamponade during ablation procedures is a life-threatening complication. While the incidence and management of tamponade in atrial fibrillation ablation have been extensively described, the data on tamponade during ventricular ablations are very limited. The purpose of this study is to shed light on the incidence, typical perforation sites, and optimal management as observed through real-life data in a tertiary referral center for ventricular ablation. METHODS AND RESULTS: Consecutive patients with structural heart disease undergoing ventricular tachycardia ablation from 2008-2020 were analyzed. Of the 1078 patients undergoing 1287 ventricular ablation procedures, 20 procedures (1.5%) were complicated by cardiac tamponade. In all but one patient, the tamponade was treated with emergent pericardial drainage, while nine patients eventually underwent surgical repair. The perforation occurred during transseptal or subxiphoid puncture in six patients, during ventricle mapping in two patients, and during ablation in five patients (predominantly basal left ventricle). Steam pop as definite perforation cause could only be established in two patients. Regardless of the management of the complication, all patients survived to discharge. CONCLUSION: Cardiac tamponade during ventricular ablation occurred in 1.5% of the procedures. In nine patients cardiac repair was necessary. Perforation was mostly associated with subxiphoid puncture or ablation of the basal left ventricle.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Humanos , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/terapia , Incidência , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ventrículos do Coração , Punções/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
3.
Europace ; 25(4): 1475-1481, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36793240

RESUMO

AIMS: Coherent mapping (CM) uses a new algorithm to identify critical conduction isthmuses of atrial tachycardias (ATs). We analysed our experience of ablation of AT in patients with congenital heart disease (CHD) with this new technology. METHODS AND RESULTS: All patients with CHD who had CM of AT using the high-density mapping PENTARAY™ catheter and three-dimensional electroanatomic mapping system Carto3 between June 2019 and June 2021 were included retrospectively (n = 27). As a control group, 27 patients with CHD and mapping of AT without CM between March 2016 and June 2019 were included. In total, 54 ablation procedures were performed in 42 patients [median age 35 (interquartile range, IQR 30-48) years] and 64 ATs were induced and mapped (thereof 50 AT intraatrial re-entrant tachycardia and 14 AT ectopic AT). The median procedure duration was 180 (120-214) min and median fluoroscopy time was 10 (5.2-14) min. Acute success was 100% (27/27) in the Coherence group and 74% (20/27) in the non-Coherence group (P = 0.01). During follow-up [median 26 (12-45) months], AT recurred in 28/54 patients, thereof 15 patients needed a re-ablation procedure. Log-rank test showed no difference in recurrence rate between the two groups (P = 0.29). Three minor complications occurred (5.5%). CONCLUSION: Mapping of AT in patients with CHD using the PENTARAY™ mapping catheter and the CM algorithm led to excellent acute success. All ATs were possible to map and no complications related to the PENTARAY™ mapping catheter were observed. Thus, the use of the CM algorithm represents a promising tool in patients with CHD and complex AT.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Taquicardia Supraventricular , Humanos , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/diagnóstico por imagem
4.
J Interv Cardiol ; 2022: 6829725, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35935125

RESUMO

Background: Catheter ablation of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) is an effective tool to prevent VT recurrences. Chronic total occlusion (CTO) represents a clinically relevant entity in ICM patients and is an independent predictor of ventricular arrhythmia and mortality. The effects of CTO on the outcome of VT ablation are not well-studied. Objective: This analysis aimed to identify the impact of CTO, revascularized, or not revascularized, on the outcome of VT ablation. Methods and Results: Of 385 consecutive subjects with ICM-VT who underwent catheter VT ablation for monomorphic VT at Heart Center Leipzig between 2008 and 2017, 108 patients without CTO and 191 patients with CTO were included in the analysis. Within a median follow-up time of 557 days (IQR 149, 1095), VT recurred in 77 (40%) patients in the CTO and 40 (37.0%) in the non-CTO cohort (p = 0.62). In a multivariable model, a 10% stepwise change in LVEF as well as ICD on admission was associated with VT recurrence (HRadj 1.82, 95% CI 1.04-3.18 and HRadj 1.35, 95% CI 1.23-1.61, respectively). Of the CTO cohort before ablation, 45% had received revascularization, which was independently associated with a higher risk for VT recurrence (HR 2.12, 95% CI 1.35-3.34) as compared to nonrevascularized CTO. Conclusion: In ICM patients with and without CTO, VT ablation was associated with equal effectiveness with regard to VT recurrence. However, in revascularized CTO patients, the risk of recurrence of VT after ablation was significantly increased.


Assuntos
Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Cardiomiopatias/complicações , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos , Humanos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Recidiva , Taquicardia Ventricular/complicações , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
5.
Europace ; 24(11): 1800-1808, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-35851396

RESUMO

AIM: Cardiac sympathetic denervation (CSD) has been introduced as a bailout therapy in patients with structural heart disease and refractory ventricular arrhythmias (VAs), but available data are scarce. Purpose of this study was to estimate immediate results, complications, and mid-term outcomes of CSD following recurrent VA after catheter ablation. METHODS AND RESULTS: Adult patients who underwent CSD in the Heart Center Leipzig from March 2017 to February 2021 were retrospectively analysed. Follow-up (FU) was executed via implantable cardioverter defibrillator (ICD) interrogation, telephone interviews, and reviewing medical records. Twenty-one patients (age 63.7 ± 14.4 years, all men, 71.4% non-ischaemic cardiomyopathy, left ventricular ejection fraction 31.6 ± 12.6%) received CSD via video-assisted thoracoscopic surgery (90.5% bilateral, 9.5% left-sided only). Indication for CSD was monomorphic ventricular tachycardia in 76.2% and ventricular fibrillation in 23.8 with 71.4% of patients presenting with electrical storm before index hospitalization. Procedure-related major complications occurred in 9.5% of patients. In-hospital adverse events not related to surgery were common (28.6%) and two patients died during the index hospital stay. During FU (mean duration 9.1 ± 6.5 months), five more patients died. Of the remaining patients, 38.5 and 76.9% were free from any VA or ICD shocks, respectively. CONCLUSIONS: The CSD showed additional moderate efficacy to suppress VAs, when performed as a bailout therapy after previously unsuccessful catheter ablation. At 9 months, it was associated with freedom of ICD shocks in two-thirds of patients. In a population with many comorbidities, the rate of CSD-related complications was acceptable, although there was an overall high risk of procedure unrelated adverse events and death.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Simpatectomia/efeitos adversos , Simpatectomia/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/cirurgia
6.
J Cardiovasc Electrophysiol ; 32(3): 766-771, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33428325

RESUMO

INTRODUCTION: This study sought to examine the feasibility and outcome of ablation of ventricular tachycardias (VTs) in a contemporary cohort of geriatric patients with structural heart disease (SHD). BACKGROUND: Geriatric patients are often underrepresented in large studies. As frailty is becoming an increasing problem, we need to examine the best course of action for this population. METHODS AND RESULTS: We investigated 68 SHD-patients ≥ 75 years old undergoing VT-ablation (men 88%, ischemic cardiomyopathy 77%, electrical storm 72%, mean left ventricular ejection fraction 31%) and divided the cohort into two groups: 75-79 years old (n = 51) and ≥80 years old (n = 17). The two groups showed similar results regarding noninducibility as ablation endpoint (p = .693), major procedure-related complications (p = .488), and VT-recurrence (p = .882) during the 39-month follow-up. At the end of the follow-up, 10 patients in the octogenarian group (59%) versus 16 patients of the other group (31%) died. CONCLUSION: Geriatric patients with SHD including octogenarians showed similar results regarding procedural endpoints, freedom of VT, and major procedure-associated complications after VT-ablation. When ablation is indicated, age alone should not be an inhibiting factor to treat these patients.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Cardiopatias/diagnóstico , Cardiopatias/cirurgia , Humanos , Masculino , Recidiva , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
7.
J Cardiovasc Electrophysiol ; 32(10): 2675-2683, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34411387

RESUMO

INTRODUCTION: This study sought to examine gender differences in patients with structural heart disease (SHD) referred for ablation of ventricular tachycardia (VT). BACKGROUND: Female patients are often underrepresented in large studies. Significant differences in the clinical presentation, treatment, and prognosis of female patients have been described in previous studies. METHODS AND RESULTS: We investigated 88 female patients with SHD undergoing VT ablation (mean age 59 years, 56% nonischemic cardiomyopathy, mean left ventricular ejection fraction 35%, 82% in electrical storm). A case-control study with 88 male patients was performed and the results regarding clinical and procedural characteristics, acute and long-term results of the two groups were compared. The female patients had more arrhythmogenic substrate, as they more commonly presented with electrical storm (p = .016) and had a higher number of inducible VT morphologies during the procedure (p = .018). Moreover, the female patients were less likely to have an optimized heart failure medical treatment at baseline (p = .030) and required more time from the first manifestation of the VT to ablation referral (p = .034). Although fewer epicardial ablations were performed in female patients (p = .019), the two groups showed similar results regarding VT noninducibility as ablation endpoint (p = .844), major procedure-related complications (p = .719) and freedom from VT during follow-up (p = .268). Moreover, the overall mortality in the two groups was similar (p = .176). Advanced NYHA class was associated with worse transplant and assist-device-free survival in the female group. CONCLUSION: Female patients presenting for VT ablation had more arrhythmogenic substrate and were less likely to have an optimized heart failure medical treatment. Nevertheless, the procedural acute and long-term outcomes between the two genders were similar.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores Sexuais , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
8.
Europace ; 23(4): 575-580, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33279992

RESUMO

AIMS: The presence of low-voltage areas (LVAs) in patients with atrial fibrillation (AF) reflects left atrial (LA) electroanatomical substrate, which is essential for individualized AF management. However, echocardiographic anteroposterior LA diameter included into previous LVAs prediction scores does not mirror LA size accurately and impaired left ventricular ejection fraction (LV-EF) is not directly associated with atrial myopathy. Therefore, we aimed to compare a modified (m)APPLE score, which included LA volume (LAV) and LA emptying fraction (LA-EF) with the regular APPLE score for the prediction of LVAs. METHODS AND RESULTS: In patients undergoing first AF catheter ablation, LVAs were determined peri-interventionally using high-density maps and defined as signal amplitude <0.5 mV. All patients underwent cardiovascular magnetic resonance imaging before intervention. The APPLE (one point for Age ≥ 65 years, Persistent AF, imPaired eGFR ≤ 60 mL/min/1.73 m2, LA diameter ≥ 43 mm, and LVEF < 50%) and (m)APPLE (last two variables changed by LAV ≥ 39 mL/m2, and LA-EF < 31%) scores were calculated at baseline. The study population included 219 patients [median age 65 (interquartile range 57-72) years, 41% females, 59% persistent AF, 25% LVAs]. Both scores were significantly associated with LVAs [OR 1.817, 95% CI 1.376-2.399 for APPLE and 2.288, 95% CI 1.650-3.172 for (m)APPLE]. Using receiver operating characteristic curves analysis, the (m)APPLE score [area under the curve (AUC) 0.779, 95% CI 0.702-0.855] showed better LVAs prediction than the APPLE score (AUC 0.704, 95% CI 0.623-0.784), however, without statistically significant difference (P = 0.233). CONCLUSION: The modified (m)APPLE score demonstrated good prognostic value for LVAs prediction and was comparable with the regular APPLE score.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Esquerda
9.
Europace ; 23(3): 409-420, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33253376

RESUMO

AIMS: Conventional His bundle pacing (HBP) can be technically challenging and fluoroscopy-intense, particularly in patients with His-Purkinje conduction disease (HPCD). Three-dimensional electroanatomical mapping (EAM) facilitates non-fluoroscopic lead navigation and HB electrogram mapping. We sought to assess the procedural outcome of routine EAM-guided HBP compared with conventional HBP in a real-world population and evaluate the feasibility and safety of EAM-guided HBP in patients with HPCD. METHODS AND RESULTS: We included 58 consecutive patients (72 ± 13 years; 71% male) who underwent an attempt to conventional (EAM- group; n = 29) or EAM-guided (EAM+ group; n = 29) HBP between June 2019 and April 2020. The centre's learning curve was initially determined (n = 40 cases) to define the conventional control group and minimize outcome bias favouring EAM-guided HBP. His bundle pacing was successful in 26 patients (90%) in the EAM+ and 27 patients (93%) in the EAM- group (P = 0.64). The procedure time was 90 (73-135) and 110 (70-130) min, respectively (P = 0.89). The total fluoroscopy time [0.7 (0.5-1.4) vs. 3.3 (1.4-6.5) min; P < 0.001] and fluoroscopy dose [21.9 (9.1-47.7) vs. 78.6 (27.2-144.9) cGycm2; P = 0.001] were significantly lower in the EAM+ than EAM- group. There were no significant differences between groups in His capture threshold (1.2 ± 0.6 vs. 1.4 ± 1.0 V/1.0 ms; P = 0.33) and paced QRS duration (113 ± 15 vs. 113 ± 17 ms; P = 0.89). In patients with HPCD, paced QRS duration was similar in both groups (121 ± 15 vs. 123 ± 12 ms; P = 0.77). The bundle branch-block recruitment threshold tended to be lower in the EAM+ than EAM- group (1.3 ± 0.7 vs. 1.8 ± 1.2 V/1.0 ms; P = 0.31). No immediate procedure-related complications occurred. One patient (2%) experienced lead dislodgement during 4-week follow-up. CONCLUSION: Implementation of routine EAM-guided HBP lead implantation is feasible and safe in a real-world cohort of patients with and without HPCD and results in a tremendous reduction in radiation exposure without prolonging procedure time or increasing procedure-related complications.


Assuntos
Fascículo Atrioventricular , Exposição à Radiação , Estimulação Cardíaca Artificial , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Resultado do Tratamento
10.
Europace ; 23(12): 1980-1988, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34405874

RESUMO

AIMS: Epicardial ablation has risen to an essential part of the treatment of ventricular tachycardias (VTs). In this study, we report the efficacy, risks, and current trends of epicardial ablation in structural heart disease as reported in a tertiary single centre over a 12-year period. METHODS AND RESULTS: Two hundred and thirty-six patients referred for VT ablation underwent a successful epicardial access and were included in the analysis (89% non-ischaemic cardiomyopathy, 90% males, mean age 60 years, mean left ventricular ejection fraction 38.4%). After performing epicardial ablation the clinical VTs were eliminated in 87% of the patients and 71% of the cohort achieved freedom from VT during 22-month follow-up. Twelve patients (5%) suffered major procedure-related complications. Until the end of follow-up 47 (20%) patients died, 9 (4%) underwent a left ventricular assist device implantation and 10 (4%) patients received a heart transplantation. Antiarrhythmic drugs at baseline and during follow-up were independent predictors of VT recurrence. Atrial fibrillation, renal dysfunction, worse New York Heart Association class, and antiarrhythmic drugs at follow-up were associated with worse survival in our cohort. CONCLUSION: In this large tertiary single-centre experience, percutaneous epicardial access was feasible in the large majority of the cohort with acceptably low complications rates. A combined endo-/epicardial approach resulted in 87% acute and 71% long-term success. Further studies are needed to clarify the role of routine combined endo-/epicardial ablation in these complex cardiomyopathies.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Cardiopatias/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
11.
Europace ; 22(11): 1672-1679, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830252

RESUMO

AIMS: Ablation of ventricular tachycardias (VTs) in patients with structural heart disease has been established in the past decades as an effective and safe treatment. However, the prognosis and long-term outcome remains poor. METHODS AND RESULTS: We investigated 309 patients with ischaemic cardiomyopathy (ICM) and non-ischaemic cardiomyopathy (NICM) (186 ICM, 123 NICM; 271 males; mean age 64.1 ± 12 years; ejection fraction 34 ± 13%) after ≥1 VT ablations over a mean follow-up period of 34 ± 28 months. Electrical storm was the indication for 224 patients (73%), whereas 86 patients (28%) underwent epicardial as well as endocardial ablation. During follow-up, 132 patients (43%) experienced VT recurrence and 97 (31%) died. Ischaemic cardiomyopathy and NICM patients showed comparable results, regarding procedural endpoints, complications, VT recurrence and survival. The Cox-regression analysis for all-cause mortality revealed that the presence of higher left ventricular end-diastolic volume (LVEDV; P < 0.001), male gender (P = 0.018), atrial fibrillation (AF; P < 0.001), chronic obstructive pulmonary disease (COPD; P = 0.001), antiarrhythmic drugs during the follow-up (P < 0.001), polymorphic VTs (P = 0.028), and periprocedural complications (P = 0.001) were independent predictors of mortality. CONCLUSION: Ischaemic cardiomyopathy and NICM patients undergoing VT ablation had comparable results regarding procedural endpoints, complications, VT recurrence and 3-year mortality. Higher LVEDV, male gender, COPD, AF, polymorphic VTs, use of antiarrhythmics, and periprocedural complications are strong and independent predictors for increased mortality. The PAINESD score accurately predicted the long-term outcome in our cohort.


Assuntos
Ablação por Cateter , Cardiopatias , Isquemia Miocárdica , Taquicardia Ventricular , Idoso , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Cardiopatias/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
12.
Europace ; 22(10): 1487-1494, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32820324

RESUMO

AIMS: The aim of the study was to determine the incidence of oesophageal lesions after radiofrequency ablation (RFA) of atrial fibrillation (AF) with or without the use of oesophageal temperature probes. METHODS AND RESULTS: Two hundred patients were prospectively randomized into two groups: the OPERA+ group underwent RFA using oesophageal probes (SensiTherm™); the OPERA- group received RFA using fixed energy levels of 25 W at the posterior wall without an oesophageal probe. All patients underwent post-interventional endoscopy and Holter-electrocardiogram after 6 months. (Clinical.Trials.gov: NCT03246594). One hundred patients were randomized in OPERA+ and 100 patients in OPERA-. The drop-out rate was 10%. In total, 18/180 (10%) patients developed endoscopically diagnosed oesophageal lesions (EDEL). There was no difference between the groups with 10/90 (11%) EDEL in OPERA+ vs. 8/90 (9%) in OPERA- (P = 0.62). Despite the higher power delivered at the posterior wall in OPERA+ [28 ± 4 vs. 25 ± 2 W (P = 0.001)], the average EDEL size was equal [5.7 ± 2.6 vs. 4.5 ± 1.7 mm (P = 0.38)]. The peak temperature did not correlate with EDEL size. During follow-up, no patient died. Only one patient in OPERA- required a specific therapy for treatment of the lesion. Cumulative AF recurrence after 6 (3-13) months was 28/87 (32%) vs. 34/88 (39%), P = 0.541. CONCLUSION: This first randomized study demonstrates that intraoesophageal temperature monitoring using the SensiTherm™ probe does not affect the probability of developing EDEL. The peak temperature measured by the thermoprobe seems not to correlate with the incidence of EDEL. Empiric energy reduction at the posterior wall did not affect the efficacy of the procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
13.
Heart Lung Circ ; 29(1): 69-85, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31262618

RESUMO

INTRODUCTION: Atrial fibrillation (AF) has been recognised as the most prevalent sustained arrhythmia. Recently, a growing body of evidence has suggested that AF might be involved in the progression of cognitive impairment (CIM), potentially extending into types of dementia. Accordingly, the purpose of the present study was to summarise the findings of investigations examining association between AF and cognitive function as well as highlighting the possible causes of discrepancy between the findings and reviewing the probable mechanisms of CIM in patients affected with AF. METHODS: A systematic search in the literature was conducted in the databases of PubMed, Scopus, Cochrane Library, and Google Scholar with no language restrictions, using specified search terms to identify studies published between 1 January 1990 and 1 April 2018. Then, study designs, participant information, diagnostic approaches used for cognitive assessments, and incidence/prevalence rates of CIM and/or dementia were assessed. RESULTS: Out of the initial 2,364 articles retrieved, a total number of 40 studies were selected for data collection. Most studies had suggested a significant relationship between AF and CIM. In this regard, cerebral hypo-perfusion, altered cerebral blood flow, cerebral micro-bleeds, micro-emboli, vascular inflammation, cerebral small vessel diseases, vascular inflammation, and genetic factors were considered as the possible mechanisms of CIM in patients suffering from AF. It seemed that differences in study settings and designs, variations of diagnostic tools for CIM and AF, as well as underlying conditions such as age groups, concurrent chronic diseases, and therapeutic interventions for AF might be amongst probable factors justifying the diversity of findings across the selected articles. CONCLUSION: Although evidence is much more directed towards an association between AF and CIM, the role of AF in CIM needs to be confirmed in-depth via longer prospective and cohort studies at larger scales using accurate neuropsychological and cognitive function assessments. Moreover, the mechanisms involved in the relationship between AF and Alzheimer's disease (AD) require further studies. To conclude, the effect of different therapeutic strategies of AF on CIM should be investigated in more clinical trials.


Assuntos
Doença de Alzheimer , Fibrilação Atrial , Transtornos Cerebrovasculares , Disfunção Cognitiva , Doença de Alzheimer/etiologia , Doença de Alzheimer/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Transtornos Cerebrovasculares/etiologia , Transtornos Cerebrovasculares/fisiopatologia , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/fisiopatologia , Humanos
14.
J Cardiovasc Electrophysiol ; 30(11): 2248-2255, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31512340

RESUMO

INTRODUCTION: The critical question for technological advancement of catheter ablation of atrial fibrillation (AF) is whether a creative new concept can combine and even improve the options of single-tip catheters with the simplicity of the use of balloon catheters. Herein are described the results from the first clinical study of a new multielectrode contact-mapping plus ablation array (Globe) offering such a complete solution. METHODS AND RESULTS: The multielectrode Globe array consists of 16 flat ribs with 122 gold-plated electrodes. Each electrode can record electrograms, ablate, pace, and can measure tissue contact and temperature. Single-shot pulmonary vein isolation (PVI) is possible with temperature-guided ablation of up to 24 electrodes simultaneously with automatic, individual power control of every electrode. Sixty patients with symptomatic AF underwent PVI using the Globe. In all sixty patients, acute PVI was achieved in 232 of 234 attempted PVs (99.1%). In 34 patients treated with "single-hot-shot" ablation, PVI was achieved in 136 of 136 PVs (100%). Single-procedure 12-month freedom from AF off antiarrhythmic drugs in the "single-hot-shot" group was 75.5% and freedom from AF/atrial tachycardia 72.3%. In two patients, pericardial tamponade was observed, one after a transseptal puncture, and one during array insertion with an over-advanced sheath. There were no other device-related serious adverse events, including stroke, PV stenosis, esophageal perforation, or phrenic nerve palsy. CONCLUSIONS: In this first clinical series, the Globe catheter was found to be an easy-to-use system for single-shot PVI. The continuously updated multielectrode voltage and activation mapping data indicate future options for mapping and ablation beyond PVI.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Eletrodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Frequência Cardíaca , Veias Pulmonares/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Resultado do Tratamento
15.
Europace ; 21(9): 1392-1399, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31102521

RESUMO

AIMS: We sought to investigate the overlap between late gadolinium enhancement (LGE) in cardiac magnetic resonance (CMR) and electro-anatomical maps (EAM) of patients with non-ischaemic dilated cardiomyopathy (NIDCM) and how it relates with the outcomes after catheter ablation of ventricular arrhythmias (VA). METHODS AND RESULTS: We identified 50 patients with NIDCM who received CMR and ablation for VA. Late gadolinium enhancement was detected in 16 (32%) patients, mostly in those presenting with sustained ventricular tachycardia (VT): 15 patients. Low-voltage areas (<1.5 mV) were observed in 23 (46%) cases; in 7 (14%) cases without evidence of LGE. Using a threshold of 1.5 mV, a good and partially good agreement between the bipolar EAM and LGE-CMR was observed in only 4 (8%) and 9 (18%) patients, respectively. With further adjustments of EAM to match the LGE, we defined new cut-off limits of median 1.5 and 5 mV for bipolar and unipolar maps, respectively. Most VT exits (12 out of 16 patients) were found in areas with LGE. VT exits were found in segments without LGE in two patients with VT recurrence as well as in two patients without recurrence, P = 0.77. In patients with VT recurrence, the LGE volume was significantly larger than in those without recurrence: 12% ± 5.8% vs. 6.9% ± 3.4%; P = 0.049. CONCLUSIONS: In NIDCM, the agreement between LGE and bipolar EAM was fairly poor but can be improved with adjustment of the thresholds for EAM according to the amount of LGE. The outcomes were related to the volume of LGE.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Técnicas Eletrofisiológicas Cardíacas/métodos , Imagem Cinética por Ressonância Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagem , Complexos Ventriculares Prematuros/diagnóstico por imagem , Adulto , Idoso , Cardiomiopatia Dilatada/fisiopatologia , Ablação por Cateter , Meios de Contraste , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
16.
Int J Sports Med ; 40(10): 657-662, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31342478

RESUMO

Competitive sports and intensive exercise are associated with adverse outcomes in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). This study aimed to assess the role of exercise on long-term results of radiofrequency catheter ablation (RFCA) therapy of ventricular tachycardia (VT) in patients with ARVD/C. Exercise participation was evaluated by telephone or in-person interviews in patients from our ARVD/C registry with previous VT ablation (38 patients, 26 males, age 52.6±14.1years). Of 38 patients, 30 were involved in sports activities before RFCA. Only the minority of our patient population (21.1%) had a sedentary lifestyle before RFCA; 42.1 and 36.8% reported recreational or competitive sports, respectively. During the follow-up period of 52.5±31.4 months, 23 of the total 38 patients with previous RFCA (60.5%) remained free from VT recurrence. In univariate and binary logistic regression analysis, only advanced age was significantly associated with VT recurrence, with a hazard ratio of 1.15, and 95% confidence interval 1.05-1.26 (p=0.004). The results of our observational study indicate that recreational sports do not impair long-term results after RFCA treatment compared with a sedentary lifestyle. Furthermore, the dynamic component of recreational exercise did not affect the outcome of VT ablation in our patient population. Recreational exercise at low to moderate intensity is not associated with an increased risk for VT recurrence after catheter ablation in patients with ARVD/C.


Assuntos
Displasia Arritmogênica Ventricular Direita/cirurgia , Ablação por Cateter , Exercício Físico , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
17.
Int Heart J ; 60(3): 527-538, 2019 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-31105147

RESUMO

Cardiogoniometry (CGM) has been proposed as a new diagnostic tool for coronary artery disease (CAD) in recent years. Although different studies have evaluated the diagnostic value of CGM in CAD diagnosis, no pooled analysis of its diagnostic accuracy has been performed so far. This study aimed to assess the value of CGM in diagnosing CAD in patients with suspected stable ischemic heart disease (SIHD).This was a systematic review and meta-analysis conducted on available literature until May 2018. Studies considered coronary angiography as the reference standard for CAD diagnosis and reported CGM diagnostic value parameters were included. No language and time restrictions for enrolling the studies were considered. Statistical analysis was performed using Meta-DiSc software.The findings of the 10 studies published in 9 articles were enrolled in the meta-analysis. Overall pooled sensitivity was 71.7% (69.1 to 74.1; Cochrane Q = 39.5; P < 0.00001; I2 = 77.3%), and pooled specificity was 78.8% (76.3 to 81.1; Cochrane Q = 37.39; P < 0.00001; I2 = 75.9%). Regarding Egger's regression test (P = 0.32), there was no published bias in the studies.It seems that CGM, as an easy-to-use and non-invasive modality, should be considered as a part of risk stratifying strategies for CAD in patients with SIHD, mainly in patients with contraindications for stress tests. However, further studies with a high quality of methodology are still needed to assess the diagnostic value of CGM for CAD in patients with suspected SIHD.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imageamento Tridimensional/métodos , Vetorcardiografia/métodos , Angiografia Coronária , Teste de Esforço , Feminino , Humanos , Masculino , Isquemia Miocárdica/diagnóstico por imagem , Sensibilidade e Especificidade
18.
Europace ; 20(12): 1952-1958, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29346552

RESUMO

Aims: Efforts to reduce radiation exposure during catheter ablation procedures have included the use of various technological measures. Significant results have been achieved to the point where near lead-free procedures in routine clinical practice has become a realistic goal. The integration of MediGuide technology [non-fluoroscopic catheter visualization technology (NFCV)] and three-dimensional electroanatomical mapping is one of the methods developed in response to radiation reduction initiatives. We aimed to evaluate the impact of this NFCV technology on atrial fibrillation (AF) catheter ablation in terms of reduction in procedural and radiation time as well as safety aspects. Methods and results: Between March 2012 and March 2017, a total of 1000 patients underwent AF ablation using NFCV. Patient and procedural data and complications within the first 3 months were entered into a prospective registry and analysed. We assessed procedure time, fluoroscopy time, and dose and complications. In a cohort of 1000 patients (62.9 ± 11 years; 72% men; left ventricular ejection fraction 57%; and left atrial diameter 43.2 mm), the median procedure time was 120 min, median fluoroscopy time was 0.90 min, and the median fluoroscopy dose of was 345.1 cGy · cm2. Stratification of the first (Group 1) and the last 250 (Group 2) cases showed significant improvement in the median procedure time (140-110 min) and reduction in the median fluoroscopy time (6-0.5 min) and the median dose (2263-151.9 cGy · cm2). The overall complication rate was 2.0%. Conclusion: The use of NFCV technology enables safe, consistent, and 'near lead-free' performance of AF ablation in routine clinical practice.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Fenômenos Eletromagnéticos , Veias Pulmonares/cirurgia , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Segurança do Paciente , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Fluxo de Trabalho
19.
Europace ; 20(7): 1182-1187, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28595345

RESUMO

Aims: This study aimed to assess the impact of supraventricular tachycardia (SVT) on long-term results of radiofrequency catheter ablation therapy of ventricular tachycardia (VT) in a large cohort of patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). Methods and results: Supraventricular tachycardia occurrence has been studied in patients from our ARVD/C registry (70 patients, 48 male, age 53.2 ± 14.0, 45 patients (64.3%) with previous VT ablation). SVT were diagnosed in 26 of 70 patients (37.1%). Atrial fibrillation (AF) was the most frequent atrial arrhythmia, diagnosed in 17 patients (24.3%). In univariate analysis advanced age, clinical symptoms of heart failure, enlarged right atrium, diagnosis of significant tricuspid regurgitation (TR), and inappropriate implantable cardioverters-defibrillators therapy were associated with SVT. In binary logistic regression analysis only heart failure: hazard ratio (HR) 10.89, 95% confidence interval (95% CI) 1.08-109.96 (P = 0.043) and significant TR: HR 4.79, 95% CI 1.35-16.33 (P = 0.015) remained associated with SVT. In patients with previous VT ablation Cox multiple regression survival analysis revealed older age (≥53 years): HR 4.63, 95% CI 1.51-14.24 (P = 0.008) and SVT: HR 3.01, 95% CI 1.15-7.89 (P = 0.025) as predictors for VT recurrence during the follow-up. Conclusion: SVT and older age are associated with the recurrence of VT after catheter ablation in patients with ARVD/C.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Ablação por Cateter , Taquicardia Supraventricular/etiologia , Taquicardia Ventricular/cirurgia , Adulto , Fatores Etários , Idoso , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
20.
J Electrocardiol ; 51(4): 574-576, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29996992

RESUMO

The diagnosis of a Hisian extrasystole is based on simple electrocardiographic features and both an extrasystole arising from the His-Bundle ("true" Hisian extrasystole) and also one from the proximal portion of the bundle branch ("pseudo" Hisian extrasystole) would be diagnosed as Hisian extrasystoles [1]. Here we report a case of "pseudo" Hisian extrasystole arising from the proximal portion of the left bundle branch and the successful catheter ablation was achieved in the right coronary cusp.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Complexos Cardíacos Prematuros , Ablação por Cateter , Eletrocardiografia , Complexos Cardíacos Prematuros/diagnóstico , Complexos Cardíacos Prematuros/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA