Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Lab ; 66(1)2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32013347

RESUMO

BACKGROUND: Platelet apheresis is a technique in which whole blood is collected from a donor followed by platelet (PLT) separation. Platelet apheresis has a significant impact on some biochemical indices after donation. This study aimed to investigate the impact of platelet apheresis on complete blood count (CBC) and lymphocyte subsets over a typical interdonation interval. METHODS: Healthy male subjects (n = 10) were recruited to study changes in CBC and lymphocyte subsets before and at three intervals following platelet apheresis. Repeated measures ANOVA was used to compare quantitative variables between different visits. RESULTS: Following platelet apheresis, platelet count decreased 30% at 24 hours after donation (p < 0.001) compared to the baseline count with significant repeated ANOVA across different visits (p < 0.001, Eta = 0.558). No changes were observed in other variables of CBC. The lymphocyte subsets including CD4, CD8, and CD4/CD8 ratio were decreased at 24 hours after donation (-0.6%, -0.4% and -0.7%, respectively) but none was significant. At 24 hours, the proportion of CD19 and CD16-56 were slightly increased (1.6%, 3.3%, p > 0.05, respectively). CONCLUSIONS: The significant reduction in PLT count after 24 hours of plateletpheresis may have adverse health effects on PLT donors. Platelet apheresis has no significant effect on lymphocyte subsets of the donor.


Assuntos
Subpopulações de Linfócitos/citologia , Plaquetoferese/efeitos adversos , Plaquetoferese/estatística & dados numéricos , Adulto , Doadores de Sangue/estatística & dados numéricos , Citometria de Fluxo , Humanos , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Adulto Jovem
2.
PLoS One ; 19(3): e0300028, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527010

RESUMO

BACKGROUND: The establishment of Reference Intervals (RIs) for Hemoglobin A1C and other hemoglobin subfractions (A1A, A1B, F, LA1C, A0) is of utmost importance in screening, diagnosing, and monitoring diabetes and other hemoglobin abnormalities through the application of high-pressure liquid chromatography (HPLC) technique. Because there are no locally established RIs for these parameters, it is essential to establish RIs specific to the Saudi population to accurately diagnose and monitor diabetic individuals and identify abnormal levels in hemoglobin subfractions. METHODS: As part of the IFCC global multicenter study of laboratory reference values, a cross-sectional study was conducted in Saudi Arabia. The study involved recruiting a total of 381 healthy adult subjects (>18 years, BMI 28.3 ± 6 kg/m2). Blood samples were analyzed for A1C, biochemical and other immunoassay parameters. The need for RIs based on sex, age, and BMI was determined using the standard deviation ratio (SDR) through a 3-level nested ANOVA. RESULTS: Based on the threshold of SDR≥0.4, RIs for A1C and other Hb subfractions were not partitioned by sex or BMI, but partitioned by age (<45 & ≥45 years) for A1C, LA1C, A0 and F. Spearman's correlation between glucose, insulin, and C-peptide showed a positive association with different hemoglobin subtractions of A1B, F, A1C, and LA1C. The RIs were obtained by using the parametric method and the latent abnormal values exclusion (LAVE) principle was applied on A1C. CONCLUSION: This study established RIs for A1C and other Hb subfractions for healthy adult Saudis. Age was found to be an important source of variation for most of the parameters including A1C. These findings will enhance the understanding and clinical decision-making concerning A1C and other hemoglobin subfractions. The elevated upper limit of RIs for A1C reflects the high prevalence of diabetes in the Saudi population specially in those with increased age.


Assuntos
Diabetes Mellitus , Hemoglobinas , População do Oriente Médio , Adulto , Humanos , Pessoa de Meia-Idade , Hemoglobinas Glicadas , Arábia Saudita , Estudos Transversais , Valores de Referência
3.
PLoS One ; 18(2): e0281494, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36753498

RESUMO

BACKGROUND: Most of hematology laboratories in Saudi Arabia utilize the reference intervals (RIs) provided by instrument manufacturers. This study aimed to define RIs of hematological parameters for adult population in the western region of Saudi Arabia and to explore their specific features from an international perspective. METHOD: This study was conducted according to the harmonized protocol of IFCC Committee on RIs and Decision Limits. Blood samples collected from 409 healthy Saudi males and females adults were analyzed for complete blood count (CBC) by using Cell-Dyn Sapphire analyzer and for iron profile by using Architect analyzers. The needs for RIs partitioned by sex and age was based on standard deviation ratio (SDR) and/or bias ratio (BR). RIs were derived parametrically with/without application of the latent abnormal values exclusion method (LAVE). RESULTS: Based on thresholds of SDR≥0.4 and/or BR≥0.57, RIs were partitioned by sex for red-blood cell count, hemoglobin, hematocrit, red cell distribution width, erythrocyte sedimentation rate, iron, transferrin, ferritin, eosinophil, platelet, plateletcrit, etc. Partitioning by age was not necessary for any of the analytes. LAVE procedure caused appreciable changes in RI limits for most erythrocyte and iron parameters but not for leukocyte parameters. Comparable to other non-IFCC studies on CBC RIs, the RBC and hematocrit (Ht) ranges have shifted to a higher side in both genders. After applying the LAVE method, the male and female RIs for Hb were 4.56 to 6.22 ×106/µL and 3.94 to 5.25 ×106/µL respectively while RIs for Ht were 40.2 to 52.0% and 33.6 to 44.5% respectively. CONCLUSION: LAVE method contributed to reducing the influence of latent anemia in deriving RIs for erythrocyte related parameters. Using the up-to-date methods, the RIs of CBC determined specifically for Saudis will help to improve the interpretation of test results in medical decision making.


Assuntos
Hematologia , Hemoglobinas , Adulto , Humanos , Masculino , Feminino , Arábia Saudita , Valores de Referência , Sedimentação Sanguínea , Ferro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA