Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Arthroplasty ; 39(5): 1157-1164, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37952739

RESUMO

BACKGROUND: Hip periprosthetic fractures (PPFs) after primary total hip arthroplasty are increasing with the number of primary implants and aging population. Mortality has been reported up to 34% at 1-year. The aim of this study was to evaluate the association of Clinical Frailty Scale (CFS) and 1-year mortality, complication rate, and length of stay (LOS) in surgically managed hip PPFs. METHODS: This was a retrospective study of prospectively collected data from January 2008 to January 2021. A total of 282 surgically managed hip PPFs were identified. Mean age was 79 years (range, 42 to 106). Preoperative scores were analyzed through linear regression to identify significant association with mortality, complication and LOS. Receiver operating characteristic curve and Area Under the Curve (AUC) were generated to evaluate the quality of the models and the discriminatory ability of each clinical score. Significance was considered at P values < .05. RESULTS: Mortality was 7.8% at 3-months and 15.7% at 1-year. Complication rate requiring surgery was 19.5% and mean LOS was 8.9 ± 7 days. The CFS was significantly associated with 3-month (odds ratio 2.23, P < .001) and 1-year mortality (odds ratio 2.01, P < .001). The receiver operating characteristic curve test for 1-year mortality showed a greater AUC for the CFS when compared with American Society for Anesthesiologists score and age-adjusted Charlson Comorbidity Index (AUC 0.80 versus 0.68 versus 0.72, respectively). CONCLUSIONS: Frailty is a syndrome with increased risk of mortality after surgically managed PPF. The CFS can be easily assessed at the time of admission and could be considered as a strong and reliable predictor of 1-year mortality with a greater AUC than the conventionally used American Society for Anesthesiologists score.

2.
J Arthroplasty ; 39(4): 1093-1107.e1, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37871862

RESUMO

BACKGROUND: Secondary patella resurfacing is often performed for dissatisfaction following primary knee arthroplasty where the native patella was retained. The purpose of this meta-analysis was to evaluate outcomes of secondary patella resurfacing. METHODS: The systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies reporting on patients who underwent secondary patella resurfacing after previous primary knee arthroplasty with retention of the native patella were considered eligible. The risk of bias was assessed using the Methodological Index for Non-Randomized studies tool. A random-effects model and the inverse-variance weighting method was used for meta-analysis. There were sixteen retrospective studies including 604 knees (594 patients) with a mean follow up of 42 months (range, 2 to 197). RESULTS: An overall improvement in patient-reported outcomes (PROMs) was achieved in 53% of cases from pooled data available for 293 knees [95% Confidence Interval (CI) (0.44, 0.62), I2=68% - moderate heterogeneity]. The pooled proportion of patients satisfied with the procedure was 59% [95% CI (48, 68), I2 = 70% - moderate heterogeneity] in a sample size of 415. There was a minimal rate (2%) of complication incidence when performing secondary patella resurfacing and a pooled rate of revision surgery of 10%. CONCLUSIONS: An improvement in pain, satisfaction, and PROMs was achieved in slightly more than half of the patients following secondary patella resurfacing. However, studies lacked standardized objective selection criteria for the procedure and the available data was predominantly retrospective, with high heterogeneity and variation in outcome reporting.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Patela/cirurgia , Estudos Retrospectivos , Dor/cirurgia , Reoperação , Resultado do Tratamento , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia
3.
J Arthroplasty ; 30(4): 706-12, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25515944

RESUMO

The effect of factors such as design, alloy and coating type on bony or fibrous tissue ingrowth was evaluated in a study of 423 retrieved cementless acetabular shells representing 16 shell designs. Small-beaded (250µm) porous coatings, either with or without hydroxyapatite (HA) coatings, proved to be the superior porous surface for bone ingrowth. Small-beaded shells that were Duofix coated had predominantly fibrous tissue ingrowth. In addition to bead size, alloy type and surface type have significant effect on bone ingrowth. In contrast, there is no significant association between bone ingrowth and time in situ, with most bone ingrowth occurring early. Although roughened, press-fit shells have acceptable clinical and Registry data, they showed some of the lowest ingrowth/ongrowth scores of all the shells tested.


Assuntos
Acetábulo/cirurgia , Prótese de Quadril , Osseointegração , Cimentação , Remoção de Dispositivo , Feminino , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Hip Int ; : 11207000241256873, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860688

RESUMO

BACKGROUND: Hip periprosthetic fractures (PPF) after total hip arthroplasty (THA) are becoming increasingly prevalent. Their management is secondary to the fracture type and the stability of the implant. This study aimed to provide the outcomes of operatively managed PPF from a high-volume centre to help guide future decision making. METHODS: This was a retrospective study of prospectively collected data from January 2008 to January 2021. Patient demographics, implant specific details, and fixation strategy were collected. Complications including infection, reoperation, re-fracture, re-revision, were collected. Short-term mortality was evaluated at 3 months and 1 year. P-values <0.05 were considered significant. RESULTS: 282 surgically managed PPF were identified. Vancouver B2 were predominant in 52% of the cases. Revision alone and revision with additional fixation were the most frequent strategies in 168 cases (60%). Complications requiring reoperation occurred in 20% of the cases, with infection as the most frequent (8.5%). Mortality rate was 7.8% at 3 months and 15.7% at 1 year, with significantly lower rates in B2 type. B2 fractures treated with cemented stems had a significantly lower 1-year mortality than distal fit revisions. CONCLUSIONS: PPF is associated with a high complication rate. Revision alone and revision with additional fixation remain the preferred method in B2/B3 type fractures, however, cemented revision can yield similar outcomes with lower short-term mortality. Considering the high-risk elderly and frail category of patients, a multidisciplinary team is necessary to improve outcomes and reduce mortality.

5.
J Bone Joint Surg Am ; 105(17): 1373-1380, 2023 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-37494460

RESUMO

➤ Young women who are 15 to 45 years of age and undergo total hip replacements are at increased risk for revision compared with women >75 years of age.➤ Among women of childbearing age with a total hip replacement, 12% to 17% will later have at least 1 pregnancy.➤ Young women who undergo total hip replacement do not have an increased risk of pregnancy complications.➤ Of the 60% of women who experienced pain with a total hip replacement during pregnancy, 21% had persisting pain, and 4% reported the pain as severe.➤ Women who have a total hip replacement and later experience pregnancy and childbirth have no increased risk of pregnancy complications or increased revision rates; there was no effect of the mode of delivery on revision rates or complications including fracture, dislocation, or loosening, according to the limited studies available.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Gravidez , Humanos , Feminino , Artroplastia de Quadril/efeitos adversos , Falha de Prótese , Quadril , Prótese de Quadril/efeitos adversos , Dor/etiologia , Artralgia/etiologia , Reoperação/efeitos adversos , Seguimentos , Estudos Retrospectivos
6.
J Orthop Surg (Hong Kong) ; 31(1): 10225536231153232, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36655735

RESUMO

PURPOSE: Since its introduction in 1988, the double-tapered polished Exeter cemented stem has been widely adopted in primary total hip arthroplasty (THA). Despite the results coming from the arthroplasty registries have proven great survivorship, the aim of this study was to dig deeper and describe the modes of failure of the Exeter stem at 15 years follow-up while reporting the clinical and radiographic outcomes. METHODS: A search of PubMed, MEDLINE, and Embase was performed using the Preferred Reporting Items for Systematic Review and Meta-Analyses since inception of database to January 2022. A meta-analysis was performed on stem's failure rates and clinical outcomes using random effects models. Publication bias was assessed with funnel plots. RESULTS: Overall, ten studies met the inclusion criteria with 2167 hips at mean 14.8 ± 4.1 years follow-up. The meta-effect estimate for revision rate for stem-related reasons was 3.8% (CI 95% 2.1-5.6, p < 0.01). The meta-effect for revision rate for stem aseptic loosening (AL) was 0.22% (CI 95% 0-0.4, p = 0.048) and for periprosthetic fracture was 0.6% (CI95% 0.3-0.9, p < 0.001). The meta effect estimate for Oxford Hip Score (OHS) at final follow-up was 32.4 (moderate; CI 95% 23.2-41.6, p <0.001) with and heterogeneity among the studies of I2 0%. Radiolucent lines were reported in 5.5% of cases, with 1.0% of cases (21 hips) reported to be progressive. CONCLUSION: Current evidence suggests that the Exeter cemented stem not only has proven long-term outstanding reliability with a revision rate of 3.8%, but also incredibly low revision rates for AL (0.22%) and periprosthetic fracture (0.6%). It is suitable for a variety of indications, and the consistent radiological appearances indicate durable fixation and load transmission while being associated with a remarkably low stem-related complication rate.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Fraturas Periprotéticas/cirurgia , Reprodutibilidade dos Testes , Seguimentos , Reoperação , Falha de Prótese , Desenho de Prótese , Fêmur/cirurgia , Artroplastia de Quadril/métodos , Cimentos Ósseos
7.
Hip Int ; 28(1): 74-83, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28967055

RESUMO

INTRODUCTION: Hip abductor tendon (HAT) tearing is commonly implicated in greater trochanteric pain syndrome. Surgical studies are often reported in small cohorts and with limited information on functional improvement. This study reports the clinical and functional outcomes after HAT repair. METHODS: 112 patients with symptomatic HAT tears, diagnosed via magnetic resonance imaging, underwent open bursectomy, V-Y lengthening of the iliotibial band, debridement of the diseased tendon, decortication of the trochanteric foot-plate and reattachment of the tendon with suture anchors, augmented with a LARS ligament through a trans-osseous tunnel. Patients were evaluated pre-surgery and at 3, 6 and 12 months post-surgery using the Harris (HHS) and Oxford (OHS) Hip Scores, SF-12, hip range of motion, 6-minute walk and 30-second single leg stance tests. Maximal isometric hip abduction strength (HAS) was assessed and limb symmetry indices (LSIs) were calculated between the operated and non-operated limbs. Patient satisfaction and perceived global rating of change (GRC) was evaluated. Analysis of variance evaluated improvement over time. RESULTS: There was a significant improvement (p<0.05) in all clinical and functional measures. HAS significantly improved over time (p<0.002) and all LSIs were >85% at 12 months. At 12 months, a mean GRC score of 3.5 (range -1 to 5) was reported, while 96% of patients were satisfied with their surgical outcome. There was a 2.7% (n = 3) failure rate at 12 months. CONCLUSIONS: HAT reconstruction, augmented with a synthetic ligament, demonstrated significantly improved clinical and functional outcomes, high levels of patient satisfaction and a low failure rate to 12 months post-surgery.


Assuntos
Artroplastia/métodos , Lesões do Quadril/cirurgia , Traumatismos dos Tendões/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Fêmur/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Recuperação de Função Fisiológica , Resultado do Tratamento
8.
Orthop J Sports Med ; 5(2): 2325967116688866, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28321422

RESUMO

BACKGROUND: Gluteal tendinopathy is a common cause of lateral hip pain, and existing conservative treatment modalities demonstrate high symptom recurrence rates. Autologous tenocyte injection (ATI) is a promising cell therapy that may be useful for the treatment of gluteal tendinopathy. PURPOSE: To investigate the safety and effectiveness of ATI, specifically in patients with chronic recalcitrant gluteal tendinopathy. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Twelve female patients with a clinical and radiological diagnosis of gluteal tendinopathy were recruited. Patients demonstrated a mean duration of symptoms of 33 months (range, 6-144 months), had undergone a mean 3.2 prior corticosteroid injections (range, 2-5), and had failed to respond to existing conservative treatments including physiotherapy and injections. In an initial procedure, tendon cells were harvested from a needle biopsy of the patella tendon and propagated in a certified Good Manufacturing Practice (GMP) laboratory. In a secondary procedure, a single injection of 2 mL autologous tenocytes (2-5 × 106 cells/mL) suspended in patient serum was injected into the site of the pathological gluteal tendons under ultrasound guidance. Patients were assessed pre- and postinjection (3, 6, 12, and 24 months) using the Oxford Hip Score (OHS), a visual analog pain scale (VAS), the Short Form-36 (SF-36), and a satisfaction scale. Magnetic resonance imaging (MRI) was undertaken at 8.7 months (range, 6-12 months) postinjection. RESULTS: Molecular characterization of autologous tendon cells showed a profile of growth factor production in all cases, including platelet-derived growth factor α, fibroblast growth factor ß, and transforming growth factor ß. The OHS (mean, 24.0 preinjection to 38.9 at 12 months [14.9-point improvement]; 95% CI, 10.6-19.2; P < .001), VAS (mean, 7.2 preinjection to 3.1 at 12 months [4.1-point improvement]; 95% CI, 2.6-5.6; P < .001), and SF-36 (mean, 28.1 preinjection to 43.3 at 12 months [15.2-point improvement]; 95% CI, 9.8-20.5; P < .001) significantly improved to 12 months postinjection, sustained to 24 months. Eight patients were satisfied with their outcomes. Significant MRI-based improvement could not be demonstrated in the majority of cases. CONCLUSION: ATI for gluteal tendinopathy is safe, with improved and sustained clinical outcomes to 24 months.

9.
Hip Int ; 25(1): 15-23, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25198307

RESUMO

Advanced hip imaging and surgical findings have demonstrated that a common cause of greater trochanteric pain syndrome (GTPS) is gluteal tendon tears. Conservative measures are initially employed to treat GTPS and manage gluteal tears, though patients frequently undergo multiple courses of non-operative treatment with only temporary pain relief. Therefore, a number of surgical treatment options for recalcitrant GTPS associated with gluteal tears have been reported. These have included open trans-osseous or bone anchored suture techniques, endoscopic methods and the use of tendon augmentation for repair reinforcement. This review describes the anatomy, pathophysiology and clinical presentation of gluteal tendon tears. Surgical techniques and patient reported outcomes are presented. This review demonstrates that surgical repair can result in improved patient outcomes, irrespective of tear aetiology, and suggests that the patient with "trochanteric bursitis" should be carefully assessed as newer surgical techniques show promise for a condition that historically has been managed conservatively.


Assuntos
Artroscopia/métodos , Lesões do Quadril/cirurgia , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Lesões do Quadril/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Ruptura , Traumatismos dos Tendões/diagnóstico
10.
Arthrosc Tech ; 3(1): e79-81, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24749046

RESUMO

The use of the 70° arthroscope in knee surgery is not a new concept, and it is frequently used in posterior cruciate ligament reconstruction. There are previous reports of its use in anterior cruciate ligament surgery, but it has not achieved routine use. With the move toward anatomic anterior cruciate ligament reconstruction, it is recognized that accurate tunnel placement is vital for a good clinical outcome. Visualization of the femoral and tibial footprints can be variable with the use of only an anterolateral viewing portal, and it may be necessary to create accessory anteromedial portals, which can cause problems with instrument crowding. Overall, the 70° arthroscope provides an excellent view of the femoral and tibial footprints and a view of the full length of the femoral and tibial tunnels through a single anterolateral viewing portal.

11.
Hip Int ; 24(2): 187-93, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24186680

RESUMO

We describe an augmented surgical repair technique for gluteus minimus and medius tears, along with a supportive case series. A consecutive series of 22 patients presenting with clinical and radiological findings consistent with hip abductor tears, who had undergone failed prior conservative treatments, were prospectively recruited. Patients underwent open bursectomy, Y-iliotibial release, debridement of the diseased tendon, decortication of the trochanteric foot-plate and reattachment augmented with a LARS ligament through a trans-osseous tunnel, together with suture anchors. All patients were assessed pre- and postoperatively to 12 months with the Oxford Hip Score (OHS), the Short-Form Health Survey (SF-36) and a Visual Analogue Pain Scale (VAS), while a satisfaction scale was employed at 12 months. A statistically significant improvement (p<0.05) was observed for all patient reported outcome measures, while all patients were at least 'satisfied' with the procedure at 12 months. One patient reported some lateral hip discomfort at 10 months, and removal of the LARS interference screw provided immediate relief. One patient had a urological catheter-related complication. With no other complications and no clinical failures of the repair, we believe the technique to be safe and reliable, whilst reducing the incidence of re-tears as reported in the existing literature.


Assuntos
Bursite/cirurgia , Procedimentos Ortopédicos/métodos , Traumatismos dos Tendões/cirurgia , Idoso , Nádegas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Ruptura , Técnicas de Sutura
12.
Proc Inst Mech Eng H ; 227(8): 875-83, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23722496

RESUMO

The number of total knee replacements being performed worldwide is undergoing an unprecedented increase. Hinged total knee replacements, used in complex salvage and revision procedures, currently account for a small but growing proportion of prostheses implanted. Modern hinged prostheses share the same basic configuration, allowing flexion-extension and tibial rotation. One aspect on which designs differ is the anteroposterior location of the hinge. A more posterior hinge is designed to increase the patellar tendon moment arm, reducing the quadriceps force required for a given activity and benefiting the patient. Five commonly used total knee replacements were evaluated in terms of quadriceps force and patellar tendon moment arm using a laboratory-based rig. Significant differences were identified between the five prostheses in quadriceps force and patellar tendon moment arm. Analysis of the correlation between these two parameters indicates that while patellar tendon moment arm influences quadriceps force, it is not the only factor. Also important is the lever function of the patella, and it is suggested here that the non-physiological nature of the prosthetic patellofemoral geometry may result in unnatural joint function. Thus, a thorough understanding of the resulting kinematic function of hinged total knee replacements is becoming increasingly important in complex revision total knee replacement to meet rising patient expectations and functional demands.


Assuntos
Prótese do Joelho , Amplitude de Movimento Articular/fisiologia , Análise de Variância , Artroplastia do Joelho , Fenômenos Biomecânicos , Humanos , Modelos Biológicos , Ligamento Patelar/fisiologia , Músculo Quadríceps/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA