Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Connect Tissue Res ; 65(4): 279-292, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38781097

RESUMO

INTRODUCTION: To mitigate the post-operative complication rates associated with massive bone allografts, tissue engineering techniques have been employed to decellularize entire bones through perfusion with a sequence of solvents. Mechanical assessment was performed in order to compare conventional massive bone allografts and perfusion/decellularized massive bone allografts. MATERIAL AND METHODS: Ten porcine femurs were included. Five were decellularized by perfusion. The remaining 5 were left untreated as the "control" group. Biomechanical testing was conducted on each bone, encompassing five different assessments: screw pull-out, 3-points bending, torsion, compression and Vickers indentation. RESULTS: Under the experimental conditions of this study, all five destructive tested variables (maximum force until screw pull-out, maximum elongation until screw pull-out, energy to pull out the screw, fracture resistance in flexion and maximum constrain of compression) were statistically significantly superior in the control group. All seven nondestructive variables (Young's modulus in flexion, Young's modulus in shear stress, Young's modulus in compression, Elastic conventional limit in compression, lengthening to rupture in compression, resilience in compression and Vickers Hardness) showed no significant difference. DISCUSSION: Descriptive statistical results suggest a tendency for the biomechanical characteristics of decellularized bone to decrease compared with the control group. However, statistical inferences demonstrated a slight significant superiority of the control group with destructive mechanical stresses. Nondestructive mechanical tests (within the elastic phase of Young's modulus) were not significantly different.


Assuntos
Aloenxertos , Fêmur , Hidróxido de Sódio , Animais , Suínos , Hidróxido de Sódio/farmacologia , Fêmur/patologia , Transplante Ósseo , Perfusão , Estresse Mecânico , Fenômenos Biomecânicos
2.
Sensors (Basel) ; 20(3)2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-32012906

RESUMO

Inertial measurement unit (IMU) records of human movement can be converted into joint angles using a sensor-to-segment calibration, also called functional calibration. This study aims to compare the accuracy and reproducibility of four functional calibration procedures for the 3D tracking of the lower limb joint angles of young healthy individuals in gait. Three methods based on segment rotations and one on segment accelerations were used to compare IMU records with an optical system for their accuracy and reproducibility. The squat functional calibration movement, offering a low range of motion of the shank, provided the least accurate measurements. A comparable accuracy was obtained in other methods with a root mean square error below 3.6° and an absolute difference in amplitude below 3.4°. The reproducibility was excellent in the sagittal plane (intra-class correlation coefficient (ICC) > 0.91, standard error of measurement (SEM) < 1.1°), good to excellent in the transverse plane (ICC > 0.87, SEM < 1.1°), and good in the frontal plane (ICC > 0.63, SEM < 1.2°). The better accuracy for proximal joints in calibration movements using segment rotations was traded to distal joints in calibration movements using segment accelerations. These results encourage further applications of IMU systems in unconstrained rehabilitative contexts.


Assuntos
Técnicas Biossensoriais , Locomoção/fisiologia , Extremidade Inferior/fisiologia , Dispositivos Eletrônicos Vestíveis , Adulto , Fenômenos Biomecânicos , Feminino , Marcha/fisiologia , Humanos , Masculino , Amplitude de Movimento Articular/fisiologia , Adulto Jovem
3.
Eur Spine J ; 26(11): 2906-2916, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28528479

RESUMO

PURPOSE: The goal of this study was to compare the accuracy of a novel intraoperative cone beam computed tomography (CBCT) imaging technique with that of conventional computed tomography (CT) scans for assessment of pedicle screw placement and breach detection. METHODS: Three hundred and forty-eight pedicle screws were inserted in 58 patients between October 2013 and March 2016. All patients had an intraoperative CBCT scan and a conventional CT scan to verify the placement of the screws. The CBCT and CT images were reviewed by two surgeons to assess the accuracy of screw placement and detect pedicle breaches using two established classification systems. Agreement on screw placement between intraoperative CBCT and postoperative CT was assessed using Kappa and Gwet's coefficients. Using CT scanning as the gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated to determine the ability of CBCT imaging to accurately evaluate screw placement. RESULTS: The Kappa coefficient was 0.78 using the Gertzbein classification and 0.80 using the Heary classification, indicating a substantial agreement between the intraoperative CBCT and postoperative CT images. Gwet's coefficient was 0.94 for both classifications, indicating almost perfect agreement. The sensitivity, specificity, positive predictive value and negative predictive value of the CBCT images were 77, 98, 86, and 96%, respectively, for the Gertzbein classification and 79, 98, 88, and 96%, respectively, for the Heary classification. CONCLUSIONS: Intraoperative CBCT provides accurate assessment of pedicle screw placement and enables intraoperative repositioning of misplaced screws. This technique may make postoperative CT imaging unnecessary.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Humanos , Período Pós-Operatório , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fusão Vertebral/estatística & dados numéricos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos
4.
Eur Spine J ; 26(11): 2917-2926, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28631190

RESUMO

PURPOSE: The goals of this study were to assess the accuracy of pedicle screw insertion using an intraoperative cone beam computed tomography (CBCT) system, and to analyze the factors potentially influencing this accuracy. METHODS: Six hundred and ninety-five pedicle screws were inserted in 118 patients between October 2013 and March 2016. Screw insertion was performed using 2D-fluoroscopy or CBCT-based navigation. Accuracy was assessed in terms of breach and reposition. All the intraoperative CBCT scans, done after screw insertion, were reviewed to assess the accuracy of screw placement using two established classification systems: Gertzbein and Heary. Generalized linear mixed models were used to model the odds (95% CI) for a screw to lead to a breach according to the independent variables. RESULTS: The breach rate was 11.7% using the Gertzbein classification and 15.4% using the Heary classification. Seventeen screws (2.4%) were repositioned intraoperatively. The only factor affecting statistically the odds to have a breach was the indication of surgery. The patients with non-degenerative disease had a significantly higher risk of breach than those with degenerative disease. CONCLUSION: Use of intraoperative CBCT as 2D-fluoroscopy or coupled with a navigation system for pedicle screw insertion is accurate in terms of breach occurrence and reposition. However, these rates depend on the classification or grading system used. Use of a navigation system does not decrease the risk of breach significantly. And the risk of breach is higher in non-degenerative conditions (trauma, scoliosis, infection, and malignancy disease) than in degenerative diseases.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Parafusos Pediculares/estatística & dados numéricos , Fusão Vertebral , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Estudos Retrospectivos , Fusão Vertebral/métodos , Fusão Vertebral/estatística & dados numéricos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos
5.
Stat Med ; 35(20): 3563-82, 2016 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-26990871

RESUMO

Resecting bone tumors requires good cutting accuracy to reduce the occurrence of local recurrence. This issue is considerably reduced with a navigated technology. The estimation of extreme proportions is challenging especially with small or moderate sample sizes. When no success is observed, the commonly used binomial proportion confidence interval is not suitable while the rule of three provides a simple solution. Unfortunately, these approaches are unable to differentiate between different unobserved events. Different delta methods and bootstrap procedures are compared in univariate and linear mixed models with simulations and real data by assuming the normality. The delta method on the z-score and parametric bootstrap provide similar results but the delta method requires the estimation of the covariance matrix of the estimates. In mixed models, the observed Fisher information matrix with unbounded variance components should be preferred. The parametric bootstrap, easier to apply, outperforms the delta method for larger sample sizes but it may be time costly. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Neoplasias Ósseas/cirurgia , Modelos Lineares , Distribuição Binomial , Humanos , Tamanho da Amostra
6.
Physiother Theory Pract ; 39(5): 938-953, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35105251

RESUMO

BACKGROUND: Scoliosis curves present transverse plane deviations due to vertebral rotation. The Schroth method supports thoracic derotation by training patients to exert "derotational" breathing based on assumed enhanced ventilation in areas called "humps" in scoliosis and a patient's ability to voluntarily direct ventilation in less ventilated areas called "flats." OBJECTIVE: To assess the asymmetric ventilation distribution and the ability of patients to direct their ventilation to perform derotational breathing. METHODS: Twelve girls with adolescent idiopathic scoliosis and 12 healthy girls performed 3 × 3 min of rest, maximal, and derotational breathing. Electrical impedance tomography was used to record locoregional lung ventilation distribution (LLVD) within 4 thoracic regions of interest: anterior right (ROI 1), anterior left (ROI 2), posterior right (ROI 3), and posterior left (ROI 4) quadrants. Humps and flats were the sums of ROI '2 + 3' and ROI '1 + 4,' respectively. RESULTS: Overall, no difference in LLVD was observed in the flats and humps between groups. At rest, the LLVD in the humps was more elevated than that in the flats (51.5 ± 8.1% versus 43.6 ± 7.9%; p = .021) when considering both groups. Maximal and derotational breathing led to a more homogeneous LLVD between the humps and flats. CONCLUSION: The postulated derotational breathing effect was not confirmed.


Assuntos
Cifose , Escoliose , Adolescente , Feminino , Humanos , Pulmão , Escoliose/terapia , Coluna Vertebral , Tomografia Computadorizada por Raios X
7.
Sci Rep ; 13(1): 18072, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872309

RESUMO

Long bone fractures are a concern in long-duration exploration missions (LDEM) where crew autonomy will exceed the current Low Earth Orbit paradigm. Current crew selection assumptions require extensive complete training and competency testing prior to flight for off-nominal situations. Analogue astronauts (n = 6) can be quickly trained to address a single fracture pattern and then competently perform the repair procedure. An easy-to-use external fixation (EZExFix) was employed to repair artificial tibial shaft fractures during an inhabited mission at the Mars Desert Research Station (Utah, USA). Bone repair safety zones were respected (23/24), participants achieved 79.2% repair success, and median completion time was 50.04 min. Just-in-time training in-mission was sufficient to become autonomous without pre-mission medical/surgical/mechanical education, regardless of learning conditions (p > 0.05). Similar techniques could be used in LDEM to increase astronauts' autonomy in traumatic injury treatment and lower skill competency requirements used in crew selection.


Assuntos
Fraturas Ósseas , Marte , Voo Espacial , Humanos , Voo Espacial/métodos , Astronautas , Utah
8.
J Clin Med ; 12(14)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37510879

RESUMO

Long bone fractures in hostile environments pose unique challenges due to limited resources, restricted access to healthcare facilities, and absence of surgical expertise. While external fixation has shown promise, the availability of trained surgeons is limited, and the procedure may frighten unexperienced personnel. Therefore, an easy-to-use external fixator (EZExFix) that can be performed by nonsurgeon individuals could provide timely and life-saving treatment in hostile environments; however, its efficacy and accuracy remain to be demonstrated. This study tested the learning curve and surgical performance of nonsurgeon analog astronauts (n = 6) in managing tibial shaft fractures by the EZExFix during a simulated Mars inhabited mission, at the Mars Desert Research Station (Hanksville, UT, USA). The reduction was achievable in the different 3D axis, although rotational reductions were more challenging. Astronauts reached similar bone-to-bone contact compared to the surgical control, indicating potential for successful fracture healing. The learning curve was not significant within the limited timeframe of the study (N = 4 surgeries lasting <1 h), but the performance was similar to surgical control. The results of this study could have important implications for fracture treatment in challenging or hostile conditions on Earth, such as war or natural disaster zones, developing countries, or settings with limited resources.

9.
Stud Health Technol Inform ; 176: 322-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22744520

RESUMO

Surgical navigation systems are useful for planning pedicle screw positioning and guiding drilling trajectories. However, it is not yet possible to intraoperatively predict the correction of the scoliotic spine resulting from specific screw and rod configuration and instrumentation maneuvers. In this context, the objective of this study is to develop a novel intraoperative simulator for navigated scoliotic spine surgeries. An instrumentation strategy (pedicle screw insertion, rod attachment and rotation, set screw tightening) was computationally simulated on a synthetic model of a scoliotic spine using the preoperative radiographs in the standing position and various parameters recreating the preoperative conditions. The intraoperative decubitus position was then simulated. The resulting geometry was identified using a navigation system and transferred to the simulator, which enabled the updating of the preoperative planning, computing of clinical indices (Cobb angles, etc.) and simulation of instrumentation maneuvers. The Cobb angle decreased from 34° to 24° between the simulated pre- and intraoperative spine (before the instrumentation). Difference in pedicle screw positioning between the preoperative planning and the intraoperative situation was less than 0.5 mm. The intraoperative simulation of the rod attachment and rotation maneuvers resulted in a 12° Cobb angle. In conclusion, this preliminary study is a first step toward developing an integrated simulator for preoperative planning and intraoperative navigation of scoliotic spine surgeries. Once completed, the new intraoperative simulator will enable the surgeon to obtain real-time biomechanical feedback during the navigated surgery of a scoliotic spine, and may contribute to improve the resulting correction and instrumentation parameters (instrumented levels, surgical maneuvers, generated forces, etc.).


Assuntos
Biomimética/instrumentação , Imageamento Tridimensional/instrumentação , Modelos Biológicos , Monitorização Intraoperatória/instrumentação , Escoliose/cirurgia , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Humanos
10.
Oncology ; 78(2): 115-24, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20357519

RESUMO

OBJECTIVES: The tumor-free margin in bone and soft-tissue cancer is a key factor for subsequent treatment. While flattening and shrinkage of specimens after formalin fixation have been described in breast cancer, there are no data for bone and soft tissue sarcoma. Fixation could interfere with the accuracy of the assessment of the tumor-free margin. METHODS: The influence of formalin fixation was assessed on forelimb specimens in a preclinical porcine model. The specimens were subjected to magnetic resonance imaging before and after formalin fixation. Weight, width and height of the specimen were measured and different consecutive volumes (total, muscles, bones and fatty tissue) were obtained by segmentation. RESULTS: After formalin fixation, the weight increased, total volume and muscle volume slightly increased while bone did not change and fatty tissue decreased. The width of the specimens increased while their height decreased. CONCLUSIONS: Formalin fixation caused slight muscle expansion, fatty tissue shrinkage and flattening of the specimen. These changes could interfere with the assessment of the tumor-free margin in clinical practice.


Assuntos
Neoplasias Ósseas/cirurgia , Fixadores/efeitos adversos , Formaldeído/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Sarcoma/cirurgia , Animais , Automação , Neoplasias Ósseas/patologia , Humanos , Modelos Animais , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/patologia , Sarcoma/patologia , Suínos , Fixação de Tecidos/métodos
11.
Acta Orthop ; 81(2): 250-5, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20175643

RESUMO

BACKGROUND AND PURPOSE: Massive bone allografts are used when surgery causes large segmental defects. Shape-matching is the primary criterion for selection of an allograft. The current selection method, based on 2-dimensional template comparison, is inefficient for 3-dimensional complex bones. We have analyzed a 3-dimensional (3-D) registration method to match the anatomy of the allograft with that of the recipient. METHODS: 3-D CT-based registration was performed to match the shapes of both bones. We used the registration to align the allograft volume onto the recipient's bone. Hemipelvic allograft selection was tested in 10 virtual recipients with a panel of 10 potential allografts, including one from the recipient himself (trap graft). 4 observers were asked to visually inspect the superposition of allograft over the recipient, to classify the allografts into 4 categories according to the matching of anatomic zones, and to select the 3 best matching allografts. The results obtained using the registration method were compared with those from a previous study on the template method. RESULTS: Using the registration method, the observers systematically detected the trap graft. Selections of the 3 best matching allografts performed using registration and template methods were different. Selection of the 3 best matching allografts was improved by the registration method. Finally, reproducibility of the selection was improved when using the registration method. INTERPRETATION: 3-D CT registration provides more useful information than the template method but the final decision lies with the surgeon, who should select the optimal allograft according to his or her own preferences and the needs of the recipient.


Assuntos
Transplante Ósseo/métodos , Imageamento Tridimensional/métodos , Ossos Pélvicos/transplante , Bancos de Ossos , Humanos , Tamanho do Órgão , Ossos Pélvicos/anatomia & histologia , Transplante Homólogo
12.
Sarcoma ; 2010: 125162, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21127723

RESUMO

Pelvic sarcoma is associated with a relatively poor prognosis, due to the difficulty in obtaining an adequate surgical margin given the complex pelvic anatomy. Magnetic resonance imaging and computerized tomography allow valuable surgical resection planning, but intraoperative localization remains hazardous. Surgical navigation systems could be of great benefit in surgical oncology, especially in difficult tumor location; however, no commercial surgical oncology software is currently available. A customized navigation software was developed and used to perform a synovial sarcoma resection and allograft reconstruction. The software permitted preoperative planning with defined target planes and intraoperative navigation with a free-hand saw blade. The allograft was cut according to the same planes. Histological examination revealed tumor-free resection margins. Allograft fitting to the pelvis of the patient was excellent and allowed stable osteosynthesis. We believe this to be the first case of combined computer-assisted tumor resection and reconstruction with an allograft.

13.
J Orthop Surg Res ; 15(1): 247, 2020 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-32631381

RESUMO

BACKGROUND: External fixation improves open fracture management in emerging countries. However, sophisticated models are often expensive and unavailable. We assessed the biomechanical properties of a low-cost external fixation system in comparison with the Hoffmann® 3 system, as a reference. METHODS: Transversal, oblique, and comminuted fractures were created in the diaphysis of tibia sawbones. Six external fixators were tested in three modes of loading-axial compression, medio-lateral (ML) bending, and torsion-in order to determine construction stiffness. The fixator construct implies two uniplanar (UUEF1, UUEF2) depending the pin-rods fixation system and two biplanar (UBEF1, UBEF2) designs based on different bar to bar connections. The designed low-cost fixators were compared to a Hoffmann® 3 fixator single rod (H3-SR) and double rod (H3-DR). Twenty-seven constructs were stabilized with UUEF1, UUEF2, and H3-SR (nine constructs each). Nine constructs were stabilized with UBEF1, UBEF2, and H3-DR (three constructs each). RESULTS: UUEF2 was significantly stiffer than H3-SR (p < 0.001) in axial compression for oblique fractures and UUEF1 was significantly stiffer than H3-SR (p = 0.009) in ML bending for transversal fractures. Both UUEFs were significantly stiffer than H3-SR in axial compression and torsion (p < 0.05), and inferior to H3-SR in ML bending, for comminuted fractures. In the same fracture pattern, UBEFs were significantly stiffer than H3-DR (p = 0.001) in axial compression and torsion, while only UBEF1 was significantly stiffer than H3-DR in ML bending (p = 0.013). CONCLUSIONS: The results demonstrated that the stiffness of the UUEF and UBEF device compares to the reference fixator and may be helpful in maintaining fracture reduction. Fatigue testing and clinical assessment must be conducted to ensure that the objective of bone healing is achievable with such low-cost devices.


Assuntos
Redução de Custos/economia , Diáfises/lesões , Fixadores Externos/economia , Fixação de Fratura/economia , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Fraturas Cominutivas/cirurgia , Tíbia/lesões , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Desenho de Equipamento , Consolidação da Fratura , Humanos , Teste de Materiais , Modelos Anatômicos
14.
J Voice ; 34(4): 609-615, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30658874

RESUMO

INTRODUCTION: Accuracy of thyroid cartilage fenestration during Montgomery thyroplasty (MTIS) is considered a key success factor. The primary aim of the study was to retrospectively evaluate the accuracy of fenestration. Furthermore, recent publications indicate a possible discrepancy in MTIS voice outcomes related to gender. The secondary aim of the study was to investigate whether the fenestration accuracy could explain this discrepancy. MATERIAL AND METHOD: Study was performed by virtually drawing the fenestration on a 3D CT scan as proposed by the MTIS's instructions for use (the "expected window" (EW)), and comparing it to the actually realized fenestration (the "realized window "(RW)). Four position variables, (a) surface overlap (%), (b) the distances between RW and EW centers (mm), (c) the angle between RW and EW (°), and (d) the orientation of RW's center, were studied and compared to MPT (seconds) and VHI-30 scores outcomes. A descriptive statistical analysis and comparison between males and females were performed using a Mann-Whitney U test. Linear regression and multivariate analysis were also performed. RESULTS: The median overlapping surface was 58.8 % [34.6; 75.4]. The median radius was 3.2 mm [1.7; 4.1]. The median angle was 16° [6.8; 21.2]. Results show no significant differences of overlapping surface percentage, distance, or angle by gender. Data show no correlation between voice outcome and percentage overlap, distance, or angle. However, data show better outcomes when fenestration was located in the infero-anterior orientation. All patients of this orientation were males. CONCLUSIONS: Data provided by this study advocate a maximal infero-anterior positioning of the window during MTIS. This position is more difficult to obtain in female patients.


Assuntos
Laringoplastia , Cartilagem Tireóidea/cirurgia , Paralisia das Pregas Vocais/cirurgia , Voz , Pontos de Referência Anatômicos , Feminino , Humanos , Imageamento Tridimensional , Masculino , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores Sexuais , Cartilagem Tireóidea/diagnóstico por imagem , Cartilagem Tireóidea/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Paralisia das Pregas Vocais/diagnóstico por imagem , Paralisia das Pregas Vocais/fisiopatologia
15.
Acta Orthop ; 79(5): 695-702, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18839378

RESUMO

BACKGROUND AND PURPOSE: Osseous pelvic tumors can be resected and reconstructed using massive bone allografts. Geometric accuracy of the conventional surgical procedure has not yet been documented. The aim of this experimental study was mainly to assess accuracy of tumoral resection with a 10-mm surgical margin, and also to evaluate the geometry of the host-graft reconstruction. METHODS: An experimental model on plastic pelvises was designed to simulate tumor resection and reconstruction. 4 experienced surgeons were asked to resect 3 different tumors and to reconstruct pelvises. 24 resections and host-graft junctions were available for evaluation. Resection margins were measured. Several methods were created to evaluate geometric properties of the host-graft junction. RESULTS: The probability of a surgeon obtaining a 10-mm surgical margin with a 5-mm tolerance above or below, was 52% (95% CI: 37-67). Maximal gap, gap volume, and mean gap between host and graft was 3.3 (SD 1.9) mm, 2.7 (SD 2.1) cm3 and 3.2 (SD 2.1) mm, respectively. Correlation between these 3 reconstruction measures and the degree of contact at the host-graft junction was poor. INTERPRETATION: 4 experienced surgeons did not manage to consistently respect a fixed surgical margin under ideal working conditions. The complex 3-dimensional architecture of the pelvis would mainly explain this inaccuracy. Solutions to this might be to increase the surgical margin or to use computer- and robotic-assisted technologies in pelvic tumor resection. Furthermore, our attempt to evaluate geometry of the pelvic reconstruction using simple parameters was not satisfactory. We believe that there is a need to define new standards of evaluation.


Assuntos
Neoplasias Ósseas/cirurgia , Transplante Ósseo , Osteossarcoma/cirurgia , Neoplasias Pélvicas/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Competência Clínica , Simulação por Computador , Humanos , Modelos Anatômicos , Modelos Biológicos , Procedimentos de Cirurgia Plástica/normas
16.
Acta Orthop Belg ; 74(5): 623-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19058695

RESUMO

Prosthesis or allograft selection usually relies on comparison of templates with radiographs of the patient. Radiographic magnification must be evaluated accurately to select the optimal implant. Radiographic magnification was retrospectively assessed in 40 patients by reference to the pelvic height measured on computed tomography scans. Intra-subject variation of the magnification was calculated in 14 patients for whom two different pelvic radiographs were available. A wide range of magnification was observed (112% to 129%) as well as a substantial intra-subject variation (8%). Paired samples t-test showed a systematic error (p < 0.001) in using 110% and 115% as magnification whereas a similar error was not found when using 120%. Mean value for magnification was 119%. Radiographic magnification measurement can be made using the pelvic height method in patients who have undergone thoraco-abdominal, abdominal or pelvic computed tomography.


Assuntos
Pelve/diagnóstico por imagem , Ampliação Radiográfica , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos
17.
Gait Posture ; 61: 141-148, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29353740

RESUMO

PURPOSE: To assess radiological and gait biomechanical changes before, at one and 10 years after surgery in AIS patients. METHODS: This clinical prospective study included fifteen adult women (mean[SD] age: 26 [1] years) diagnosed with thoraco-lumbar/lumbar AIS and operated 10 years ago. Clinical, radiological and gait variables, including kinematics, electromyography (EMG), mechanics and energetics were compared between presurgery (S0), 1 year (S1) and 10 years (S2) postsurgery period using a one way repeated measure ANOVA. RESULTS: The Cobb angle of the scoliosis curve was reduced by 55% at 1 year postsugery but only by 37% at 10 years postsurgery suggesting a loss of 32% over time. Frontal plumb line C7-S1 distance was significantly improved by surgery (-44%) and remained stable at 10 years postsurgery. Lower limb kinematics was not affected by the surgery at long term. Excessive bilateral activation of lombo-pelvic muscles, observed before surgery, decreased significantly at S1 and S2 period. Mechanical energy increased significantly between S0, S1 and S2 session, without any change for the energetic variables. CONCLUSIONS: Between 1 and 10 years post-surgery, thoraco-lumbar/lumbar AIS women showed a few decompensation of the curve without any change of the improved frontal body balance. Lower limbs and pelvic motion, during gait, was not affected by the surgery. But presurgical excessive EMG activity of the lumbo-pelvic muscle and reduced mechanical energy produced to walk get similar to normal patterns. Only the oxygen consumption remained excessive probably due to physical deconditioning or postural instability.


Assuntos
Previsões , Marcha/fisiologia , Vértebras Lombares/cirurgia , Músculo Esquelético/fisiopatologia , Escoliose/fisiopatologia , Fusão Vertebral , Caminhada/fisiologia , Adolescente , Adulto , Eletromiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Escoliose/cirurgia , Adulto Jovem
18.
J Bone Joint Surg Am ; 99(8): e39, 2017 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-28419041

RESUMO

Surgical accuracy is multifactorial. Therefore, it is crucial to consider all influencing factors when investigating the accuracy of a surgical procedure, such as the surgeon's experience, the assistive technologies that may be used by the surgeon, and the patient factors associated with the specific anatomical site. For in vitro preclinical investigations, accuracy should be linked to the concepts of trueness (e.g., distance from the surgical target) and precision (e.g., variability in relation to the surgical target) to gather preclinical, quantitative, objective data on the accuracy of completed surgical procedures that have been performed with assistive technologies. The clinical relevance of improvements in accuracy that have been observed experimentally may be evaluated by analyzing the impact on the risk of failure and by taking into account the level of tolerance in relation to the surgical target (e.g., the extent of the safety zone). The International Organization for Standardization (ISO) methodology enables preclinical testing of new assistive technologies to quantify improvements in accuracy and assess the benefits in terms of reducing the risk of failure and achieving surgical targets with tighter tolerances before the testing of clinical outcomes.


Assuntos
Procedimentos Ortopédicos/normas , Cirurgia Assistida por Computador/normas , Humanos , Procedimentos Ortopédicos/métodos , Cirurgia Assistida por Computador/métodos
19.
Sarcoma ; 2014: 842709, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25100921

RESUMO

Pelvic bone tumor resection is challenging due to complex geometry, limited visibility, and restricted workspace. Accurate resection including a safe margin is required to decrease the risk of local recurrence. This clinical study reports 11 cases of pelvic bone tumor resected by using patient-specific instruments. Magnetic resonance imaging was used to delineate the tumor and computerized tomography to localize it in 3D. Resection planning consisted in desired cutting planes around the tumor including a safe margin. The instruments were designed to fit into unique position on the bony structure and to indicate the desired resection planes. Intraoperatively, instruments were positioned freehand by the surgeon and bone cutting was performed with an oscillating saw. Histopathological analysis of resected specimens showed tumor-free bone resection margins for all cases. Available postoperative computed tomography was registered to preoperative computed tomography to measure location accuracy (minimal distance between an achieved and desired cut planes) and errors on safe margin (minimal distance between the achieved cut planes and the tumor boundary). The location accuracy averaged 2.5 mm. Errors in safe margin averaged -0.8 mm. Instruments described in this study may improve bone tumor surgery within the pelvis by providing good cutting accuracy and clinically acceptable margins.

20.
Sarcoma ; 2014: 967848, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24976785

RESUMO

In 12 patients operated on for bone sarcoma resection, a postoperative magnetic resonance imaging of the resection specimens was obtained in order to assess the surgical margins. Margins were classified according to MRI in R0, R1, and R2 by three independent observers: a radiologist and two orthopaedic surgeons. Final margin evaluation (R0, R1, and R2) was assessed by a confirmed pathologist. Agreement for margin evaluation between the pathologist and the radiologist was perfect (κ = 1). Agreement between the pathologist and an experienced orthopaedic surgeon was very good while it was fair between the pathologist and a junior orthopaedic surgeon. MRI should be considered as a tool to give quick information about the adequacy of margins and to help the pathologist to focus on doubtful areas and to spare time in specimen analysis. But it may not replace the pathological evaluation that gives additional information about tumor necrosis. This study shows that MRI extemporaneous analysis of a resection specimen may be efficient in bone tumor oncologic surgery, if made by an experienced radiologist with perfect agreement with the pathologist.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA