1.
Magn Reson Med ; 81(1): 220-233, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30058085

RESUMO

PURPOSE: To develop high-spatial-resolution cardiac T2 mapping that allows for a reduced acquisition time while maintaining its precision. We implemented and optimized a new golden-angle radial T2 mapping technique named SKRATCH (Shared k-space Radial T2 Characterization of the Heart) that shares k-space peripheries of T2 -weighted images while preserving their contrasts. METHODS: Six SKRATCH variants (gradient-recalled echo and balanced SSFP, free-breathing and breath-held, with and without a saturation preparation) were implemented, and their precision was compared with a navigator-gated reference technique in phantoms and 22 healthy volunteers at 3 T. The optimal breath-held SKRATCH technique was applied in a small cohort of patients with subacute myocardial infarction. RESULTS: The faster free-breathing SKRATCH technique reduced the acquisition time by 52.4%, while maintaining the precision and spatial resolution of the reference technique. Similarly, the most precise and robust breath-held SKRATCH technique demonstrated homogenous T2 values that did not significantly differ from the navigator-gated reference (T2 = 39.9 ± 3.4 ms versus 39.5 ± 3.4 ms, P > .20, respectively). All infarct patients demonstrated a large T2 elevation in the ischemic regions of the myocardium. CONCLUSION: The optimized SKRATCH technique enabled the accelerated acquisition of high-spatial-resolution T2 maps, was validated in healthy adult volunteers, and was successfully applied to a small initial group of patients.


Assuntos
Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Respiração , Adulto , Idoso , Algoritmos , Suspensão da Respiração , Meios de Contraste , Eletrocardiografia , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Miocárdio , Variações Dependentes do Observador , Imagens de Fantasmas , Reprodutibilidade dos Testes , Pesquisa Translacional Biomédica , Adulto Jovem
2.
Magn Reson Med ; 79(1): 108-120, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28261859

RESUMO

PURPOSE: MRI has been used to noninvasively assess coronary endothelial function by measuring the vasoreactivity in response to handgrip exercise. However, the spatial resolution of MRI is limited relative to the expected vasodilation response of healthy coronary arteries (10%-20%), and the sensitivity of MRI to detect such small cross-sectional area differences has yet to be quantitatively examined. METHODS: Holes of different diameters were drilled in a phantom to simulate a range of physiological responses of coronary arteries to stress. Radial cine MR images with different spatial resolutions were acquired under moving conditions, and different noise levels were simulated. Cross-sectional areas were automatically measured and statistically analyzed to quantify the smallest detectable area difference. RESULTS: Statistical analyses suggest that radial MRI is capable of distinguishing area differences of 0.2 to 0.3 mm2 for high signal-to-noise ratio images, which correspond to a percentage coronary area difference of 3% to 4% for a 3-mm baseline diameter. Furthermore, the smallest detectable area difference was largely independent of the pixel size for the sequence and range of diameters investigated in this study. CONCLUSION: Radial MRI is capable of reliably detecting small differences in cross-sectional areas that are well within the expected physiological range of stress-induced area changes in of healthy coronary arteries. Magn Reson Med 79:108-120, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Vasos Coronários/diagnóstico por imagem , Endotélio Vascular/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Algoritmos , Análise de Variância , Área Sob a Curva , Circulação Coronária , Humanos , Processamento de Imagem Assistida por Computador , Limite de Detecção , Modelos Cardiovasculares , Modelos Estatísticos , Movimento , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Vasodilatação
3.
Magn Reson Med ; 79(4): 2297-2305, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28856720

RESUMO

PURPOSE: Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time sequence. METHODS: A 3D double-echo ultra-short echo time sequence was used to acquire data during free breathing in ten healthy adult subjects. A self-gating method was used to reconstruct respiratory motion suppressed expiratory and inspiratory images. These images were objectively compared to uncorrected data sets using quantitative end-points (pulmonary vessel sharpness, lung-liver interface definition, signal-to-noise ratio). The method was preliminarily tested in two cystic fibrosis patients who underwent computed tomography. RESULTS: Vessel sharpness in expiratory ultra-short echo time data sets with second echo motion detection was significantly higher (13% relative increase) than in uncorrected images while the opposite was observed in inspiratory images. The method was successfully applied in patients and some findings (e.g., hypointense areas) were similar to those from computed tomography. CONCLUSION: Free breathing ultra-short echo time was successfully implemented, allowing flexible image reconstruction of two different respiratory states. Objective improvements in image quality were obtained with the new method and initial feasibility in a clinical setting was demonstrated. Magn Reson Med 79:2297-2305, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Fibrose Cística/diagnóstico por imagem , Imagem Ecoplanar , Pulmão/diagnóstico por imagem , Respiração , Adulto , Algoritmos , Eletrocardiografia , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Movimento (Física) , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
4.
Magn Reson Med ; 79(3): 1293-1303, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28568961

RESUMO

PURPOSE: In respiratory self-navigation (SN), signal from static structures, such as the chest wall, may complicate motion detection or introduce post-correction artefacts. Suppressing signal from superfluous tissues may therefore improve image quality. We thus test the hypothesis that SN whole-heart coronary magnetic resonance angiography (MRA) will benefit from an outer-volume suppressing 2D-T2 -Prep and present both phantom and in vivo results. METHODS: A 2D-T2 -Prep and a conventional T2 -Prep were used prior to a free-breathing 3D-radial SN sequence. Both techniques were compared by imaging a home-built moving cardiac phantom and by performing coronary MRA in nine healthy volunteers. Reconstructions were performed using both a reference-based and a reference-independent approach to motion tracking, along with several coil combinations. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared, along with vessel sharpness (VS). RESULTS: In phantoms, using the 2D-T2 -Prep increased SNR by 16% to 53% and mean VS by 8%; improved motion tracking precision was also achieved. In volunteers, SNR increased by an average of 29% to 33% in the blood pool and by 15% to 25% in the myocardium, depending on the choice of reconstruction coils and algorithm, and VS increased by 34%. CONCLUSION: A 2D-T2 -Prep significantly improves image quality in both phantoms and volunteers when performing SN coronary MRA. Magn Reson Med 79:1293-1303, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Angiografia Coronária/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Algoritmos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Imagens de Fantasmas
5.
MAGMA ; 30(3): 215-225, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27844220

RESUMO

OBJECTIVES: Our objective was to test a data-exclusion strategy for respiratory motion suppression by retrospectively eliminating data acquired at extreme respiratory positions for improved coronary vessel sharpness (VS) of 1-D self-navigated 3-D radial whole-heart coronary angiography acquisitions. MATERIALS AND METHODS: 3-D radial self-navigated acquisitions were performed on a 1.5T scanner in volunteers during free-breathing (n = 8), in coached volunteers (n = 13) who were asked to breathe in a controlled manner to mimic cardiovascular patients presenting with Cheyne-Stokes breathing, and in free-breathing patients (n = 20). Data collected during large respiratory excursions were gradually excluded retrospectively from the reconstruction yielding 14 data sets per subject on average. The impact on VS, blood and myocardium signal-to-noise and contrast-to-noise was measured. From these results, two retrospective gating strategies were defined for the k-line elimination procedure and tested in all groups. RESULTS: Maximum right coronary artery VS improvement was +7.4 and +2.7% in coached volunteers and patients (P < 0.0001 for both), respectively, and 1.6% for the free-breathing volunteers (P = 0.13). The first gating strategy was defined as a fixed undersampling factor of 5 compared to a fully sampled 3-D radial acquisition, yielding significant VS improvement in coached volunteers and patients while myocardial signal-to-noise decreased in these. The second strategy was defined as a fixed gating window of 5.7 mm, leading to similar improvements. CONCLUSION: The presented strategies improve image quality of self-navigated acquisitions by retrospectively excluding data collected during end-inspiration.


Assuntos
Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Cardiopatias/diagnóstico por imagem , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
6.
Magn Reson Med ; 74(5): 1306-16, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25376772

RESUMO

PURPOSE: To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four-dimensional (4D) acquisition. METHODS: A free-running 4D whole-heart self-navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self-navigated electrocardiography (ECG) -triggered coronary MRA. From the 4D datasets, the left-ventricular end-systolic, end-diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images. RESULTS: The 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm(3). Coronary artery image quality was very similar to that of the ECG-triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF. CONCLUSION: The hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Feminino , Coração/anatomia & histologia , Coração/fisiologia , Humanos , Masculino , Razão Sinal-Ruído , Adulto Jovem
7.
Radiology ; 270(2): 378-86, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24471387

RESUMO

PURPOSE: To assess the diagnostic performance of respiratory self-navigation for whole-heart coronary magnetic resonance (MR) angiography in a patient cohort referred for diagnostic cardiac MR imaging. MATERIALS AND METHODS: Written informed consent was obtained from all participants for this institutional review board-approved study. Self-navigated coronary MR angiography was performed after administration of a contrast agent in 78 patients (mean age, 48.5 years ± 20.7 [standard deviation]; 53 male patients) referred for cardiac MR imaging because of coronary artery disease (n = 40), cardiomyopathy (n = 14), congenital anomaly (n = 17), or "other" (n = 7). Examination duration was recorded, and the image quality for each coronary segment was assessed with consensus reading. Vessel sharpness, length, and diameter were measured. Quantitative values in proximal, middle, and distal segments were compared by using analysis of variance and t tests. A double-blinded comparison with the results of x-ray angiography was performed when such results were available. RESULTS: When patients with different indications for cardiac MR imaging were examined with self-navigated postcontrast coronary MR angiography, whole-heart data sets with 1.15-mm isotropic spatial resolution were acquired in an average of 7.38 minutes ± 1.85. The main and proximal coronary segments could be visualized in 92.3% of cases, while the middle and distal segments could be visualized in 84.0% and 55.8% of cases, respectively. Subjective scores and vessel sharpness were significantly higher in the proximal segments than in the middle and distal segments (P < .05). Anomalies of the coronary arteries could be confirmed or excluded in all cases. Per-vessel sensitivity and specificity for stenosis detection were 64.7% and 85.0%, respectively, in the 31 patients for whom reference standard x-ray coronary angiography results were available. CONCLUSION: The self-navigated coronary MR angiography sequence shows promise for coronary imaging. However, technical improvements are needed to improve image quality, especially in the more distal coronary segments.


Assuntos
Cardiopatias/diagnóstico , Angiografia por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Meios de Contraste , Angiografia Coronária , Método Duplo-Cego , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Respiração
8.
Sci Rep ; 8(1): 7886, 2018 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-29760513

RESUMO

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.

9.
Sci Rep ; 7(1): 15540, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29138508

RESUMO

Fast magnetic resonance imaging (MRI) led to the emergence of 'cine MRI' techniques, which enable the visualization of the beating heart and the assessment of cardiac morphology and dynamics. However, established cine MRI methods are not suitable for fetal heart imaging in utero, where anatomical structures are considerably smaller and recording an electrocardiogram signal for synchronizing MRI data acquisition is difficult. Here we present a framework to overcome these challenges. We use methods for image acquisition and reconstruction that robustly produce images with sufficient spatial and temporal resolution to detect the heart contractions of the fetus, enabling a retrospective gating of the images and thus the generation of images of the beating heart. To underline the potential of our approach, we acquired in utero images in six pregnant patients and compared these with their echocardiograms. We found good agreement in terms of diameter and area measurements, and low inter- and intra- observer variability. These results establish MRI as a reliable modality for fetal cardiac imaging, with a substantial potential for prenatal evaluation of congenital heart defects.


Assuntos
Coração Fetal/ultraestrutura , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Técnicas de Imagem Cardíaca/métodos , Feminino , Coração Fetal/anormalidades , Humanos , Gravidez , Reprodutibilidade dos Testes
10.
Int J Cardiovasc Imaging ; 32(12): 1735-1744, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27549804

RESUMO

The border zone of post-infarction myocardial scar as identified by late gadolinium enhancement (LGE) has been identified as a substrate for arrhythmias and consequently, high-resolution 3D scar information is potentially useful for planning of electrophysiological interventions. This study evaluates the performance of a novel high-resolution 3D self-navigated free-breathing inversion recovery magnetic resonance pulse sequence (3D-SN-LGE) vs. conventional 2D breath-hold LGE (2D-LGE) with regard to sharpness of borders (SBorder) of post-infarction scar. Patients with post-infarction scar underwent two magnetic resonance examinations for conventional 2D-LGE and high-resolution 3D-SN-LGE acquisitions (both 15 min after 0.2 mmol/kg Gadobutrol IV) at 1.5T. In the prototype 3D-SN-LGE sequence, each ECG-triggered radial steady-state-free-precession read-out segment is preceded by a non-slice-selective inversion pulse. Scar volume and SBorder were assessed on 2D-LGE and matching reconstructed high-resolution 3D-SN-LGE short-axis slices. In 16 patients (four females, 58 ± 10y) all scars visualized by 2D-LGE could be identified on 3D-SN-LGE (time between 2D-LGE and 3D-SN-LGE 48 ± 53 days). A good agreement of scar volume by 3D-SN-LGE vs. 2D-LGE was found (Bland-Altman: -3.7 ± 3.4 ml, correlation: r = 0.987, p < 0.001) with a small difference in scar volume (20.5 (15.8, 35.2) ml vs. 24.5 (20.0, 41.9)) ml, respectively, p = 0.002] and a good intra- and interobserver variability (1.1 ± 4.1 and -1.1 ± 11.9 ml, respectively). SBorder of border "scar to non-infarcted myocardium" was superior on 3D-SN-LGE vs. 2D-LGE: 0.180 ± 0.044 vs. 0.083 ± 0.038, p < 0.001. Detection and quantification of myocardial scar by 3D-SN-LGE is feasible and accurate in comparison to 2D-LGE. The high spatial resolution of the 3D sequence improves delineation of scar borders.


Assuntos
Cicatriz/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Respiração , Idoso , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
11.
JACC Cardiovasc Imaging ; 7(9): 882-92, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25129517

RESUMO

OBJECTIVES: The purpose of this study was to compare a novel compressed sensing (CS)-based single-breath-hold multislice magnetic resonance cine technique with the standard multi-breath-hold technique for the assessment of left ventricular (LV) volumes and function. BACKGROUND: Cardiac magnetic resonance is generally accepted as the gold standard for LV volume and function assessment. LV function is 1 of the most important cardiac parameters for diagnosis and the monitoring of treatment effects. Recently, CS techniques have emerged as a means to accelerate data acquisition. METHODS: The prototype CS cine sequence acquires 3 long-axis and 4 short-axis cine loops in 1 single breath-hold (temporal/spatial resolution: 30 ms/1.5 × 1.5 mm(2); acceleration factor 11.0) to measure left ventricular ejection fraction (LVEF(CS)) as well as LV volumes and LV mass using LV model-based 4D software. For comparison, a conventional stack of multi-breath-hold cine images was acquired (temporal/spatial resolution 40 ms/1.2 × 1.6 mm(2)). As a reference for the left ventricular stroke volume (LVSV), aortic flow was measured by phase-contrast acquisition. RESULTS: In 94% of the 33 participants (12 volunteers: mean age 33 ± 7 years; 21 patients: mean age 63 ± 13 years with different LV pathologies), the image quality of the CS acquisitions was excellent. LVEF(CS) and LVEF(standard) were similar (48.5 ± 15.9% vs. 49.8 ± 15.8%; p = 0.11; r = 0.96; slope 0.97; p < 0.00001). Agreement of LVSV(CS) with aortic flow was superior to that of LVSV(standard) (overestimation vs. aortic flow: 5.6 ± 6.5 ml vs. 16.2 ± 11.7 ml, respectively; p = 0.012) with less variability (r = 0.91; p < 0.00001 for the CS technique vs. r = 0.71; p < 0.01 for the standard technique). The intraobserver and interobserver agreement for all CS parameters was good (slopes 0.93 to 1.06; r = 0.90 to 0.99). CONCLUSIONS: The results demonstrated the feasibility of applying the CS strategy to evaluate LV function and volumes with high accuracy in patients. The single-breath-hold CS strategy has the potential to replace the multi-breath-hold standard cardiac magnetic resonance technique.


Assuntos
Suspensão da Respiração , Ventrículos do Coração/fisiopatologia , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda , Adulto , Idoso , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA