Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Front Neurol ; 15: 1325527, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803648

RESUMO

Background: The primary objective is to evaluate the safety and effectiveness of Stryker second generation Target® Nano Coils in the treatment of ruptured and unruptured small (<7 mm) intracranial aneurysms. Methods: The TARGET Registry is a prospective, two-arm study with independent medical event monitoring and core-lab adjudication. This paper describes the second arm of the TARGET registry. Patients with de novo intracranial aneurysms were embolized with 2nd generation TARGET Nano coils in 12 US centers. The primary efficacy outcome was adequate aneurysm occlusion (RR occlusion grade I-II) on follow-up. Primary safety outcome was treatment-related morbidity and mortality. Secondary outcomes included aneurysm packing density immediately post-procedure, immediate adequate occlusion, aneurysm re-access rate, retreatment rate and clinical outcomes using modified ranking scale. A secondary analysis investigated the influence of using Nano-predominant coils (≥2/3 of total coil-length) vs. non-Nano-predominant coils (<2/3 of total length). Results: 150 patients with 155 aneurysms met the inclusion and exclusion criteria. (31%) patients with ruptured and (69%) with unruptured aneurysms were treated using TARGET coils. Median age was 58.8 (SD 12.7), 74.7% were females, and 80% were Caucasians. Mean follow-up was 5.23 (SD 2.27) months. Peri-procedural mortality was seen in 2.0% of patients. Good outcome at discharge (mRS 0-2) was seen in 81.3% of the cohort. The median packing density (SD) was 29.4% (14.9). Mid-term complete/near complete occlusion rate was seen in 96% of aneurysms and complete obliteration was seen in 75.2% of aneurysms. Patients treated predominantly with Nano coils had higher PD (32.6% vs. 26.1%, p < 0.001). There was no significant difference in clinical and angiographic outcomes. The mid-term mRS0-2 was achieved in 106/109 (97.2%) patients. All-cause mortality was 5/115 (4.3%). Conclusion: In the multicenter TARGET Registry, 75.8% of aneurysms achieved mid-term complete occlusion, and 96% achieved complete/near complete occlusion with excellent independent functional outcome.

2.
J Neurointerv Surg ; 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195248

RESUMO

BACKGROUND: Patients treated with mechanical thrombectomy (MT) for acute ischemic strokes from large vessel occlusion (LVO) have better outcomes with effective reperfusion. However, it is unknown which technique leads to better technical and clinical success. We aimed to determine which technique yields the most effective first pass reperfusion during MT. METHODS: In a prospective, multicenter global registry we enrolled patients treated with operator preferred MT technique at 71 hospitals from January 2019 to January 2022. Three techniques were assessed: SR Classic with stent retriever (SR) and balloon guide catheter (BGC); SR Combination which employed SR with contact aspiration with or without BGC; and direct aspiration (DA) with or without BGC. The primary outcome was achieving an expanded Thrombolysis In Cerebral Infarction (eTICI) score of 2c or 3 on the first pass, with the primary technique as adjudicated by core lab. The primary clinical outcome measure was a 90-day modified Rankin Scale (mRS) score of 0-2. RESULTS: A total of 1492 patients were enrolled. Patients treated with SR Classic or SR Combination were more likely to achieve first pass eTICI 2c or 3 reperfusion (P=0.01). There was no significant difference in mRS 0-2 (P=0.46) or safety endpoints. CONCLUSIONS: The use of SR Classic or SR Combination was more likely to achieve first pass eTICI 2c or 3 reperfusion. There were no significant differences in clinical outcomes and safety endpoints.

3.
Interv Neuroradiol ; 29(4): 481-487, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37455501

RESUMO

Intrasaccular flow disruption is a viable alternative to other endovascular treatments for saccular or wide-necked bifurcation intracranial aneurysms; however, wide neck aneurysms with irregular shapes or shallow depth may not be amenable to treatment currently available intrasaccular devices. Here, we present the first ever case report of the novel Saccular Endovascular Aneurysm Lattice Embolization System (SEAL™). The versatile utility of the SEAL™ device is demonstrated in a patient with acute subarachnoid hemorrhage (SAH) from a ruptured, complex, left middle cerebral artery (MCA) trilobed shallow wide-necked bifurcation aneurysm. Deployment and implantation of the SEAL device were technically feasible, safe, and conformed well to the irregular shape of the complex, ruptured aneurysm. Immediate total aneurysm occlusion was observed after implantation. Importantly, 1-year angiographic follow-up demonstrated durable, complete occlusion with no safety concerns. The SEAL device is a promising new novel technology which has the potential to treat very shallow aneurysms with limited height and irregular, multilobulated aneurysms.


Assuntos
Aneurisma Roto , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Seguimentos , Resultado do Tratamento , Aneurisma da Aorta Abdominal/cirurgia , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Aneurisma Roto/terapia , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , Angiografia Cerebral
4.
Artigo em Inglês | MEDLINE | ID: mdl-33614199

RESUMO

The novel coronavirus SARS-CoV-2 (severe acute respiratory syndrome coronavirus-2) is the cause of the COVID-19 pandemic [5]. SARS-Cov-2 demonstrates partial resemblance to SARS-CoV and MERS-CoV in phylogenetic analysis, clinical manifestations, and pathological findings [6, 7]. Reports emerging from China have described ataxia as a neurological symptom of the SARS-CoV-2 infection [5]. Opsoclonus consists of back-to-back multidirectional conjugate saccades without an inter-saccadic interval [8]. Myoclonus is defined as a sudden, brief, "shock-like", nonepileptic involuntary movement [9], which has been described as a symptom of SARS-CoV-2 infection [10]. Opsoclonus-Myoclonus-Ataxia syndrome (OMAS) associated COVID-19 infection has been reported recently [1112].


Assuntos
COVID-19/fisiopatologia , Síndrome de Opsoclonia-Mioclonia/fisiopatologia , Adulto , COVID-19/complicações , Clonazepam/uso terapêutico , GABAérgicos/uso terapêutico , Humanos , Masculino , Metilprednisolona/uso terapêutico , Fármacos Neuroprotetores/uso terapêutico , Síndrome de Opsoclonia-Mioclonia/tratamento farmacológico , Síndrome de Opsoclonia-Mioclonia/etiologia , Prognóstico , Recuperação de Função Fisiológica , SARS-CoV-2 , Resultado do Tratamento , Ácido Valproico/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA