Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Gastroenterol ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38775310

RESUMO

INTRODUCTION: Concerns regarding bleeding remain in cold snare polypectomy (CSP) for small pedunculated (0-Ip) polyps. The aim of this study was to compare the risk of CSP and hot snare polypectomy (HSP) for such lesions. METHODS: Data on 0-Ip colorectal polyps ≤10 mm were extracted from a large, pragmatic, randomized trial. Immediate postpolypectomy bleeding (IPPB), defined as the perioperative use of a clip for bleeding, was evaluated through polyp-level analysis. Delayed postpolypectomy bleeding (DPPB), defined as bleeding occurring within 2 weeks postoperatively, was assessed at the patient-level among patients whose polyps were all ≤10 mm, including at least one 0-Ip polyp. RESULTS: A total of 647 0-Ip polyps (CSP: 306; HSP: 341) were included for IPPB analysis and 386 patients (CSP: 192; HSP: 194) for DPPB analysis. CSP was associated with a higher incidence of IPPB (10.8% vs 3.2%, P < 0.001) but no adverse clinical events. The procedure time of all polypectomies was shorter for CSP than for HSP (123.0 ± 117.8 vs 166.0 ± 237.7 seconds, P = 0.003), while the procedure time of polypectomies with IPPB were similar (249.8 ± 140.2 vs 227.4 ± 125.9 seconds, P = 0.64). DPPB was observed in 3 patients (1.5%) in the HSP group, including one patient (0.5%) with severe bleeding, but not in the CSP group. DISCUSSION: Despite CSP being associated with more IPPB events, it could be timely treated without adverse outcomes. Notably, no delayed bleeding occurred in the CSP group. Our findings support the use of CSP for 0-Ip polyps ≤ 10 mm.

2.
Ann Intern Med ; 176(3): 311-319, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802753

RESUMO

BACKGROUND: Although cold snare polypectomy (CSP) is considered effective in reducing delayed postpolypectomy bleeding risk, direct evidence supporting its safety in the general population remains lacking. OBJECTIVE: To clarify whether CSP would reduce delayed bleeding risk after polypectomy compared with hot snare polypectomy (HSP) in the general population. DESIGN: Multicenter randomized controlled study. (ClinicalTrials.gov: NCT03373136). SETTING: 6 sites in Taiwan, July 2018 through July 2020. PARTICIPANTS: Participants aged 40 years or older with polyps of 4 to 10 mm. INTERVENTION: CSP or HSP to remove polyps of 4 to 10 mm. MEASUREMENTS: The primary outcome was the delayed bleeding rate within 14 days after polypectomy. Severe bleeding was defined as a decrease in hemoglobin concentration of 20 g/L or more, requiring transfusion or hemostasis. Secondary outcomes included mean polypectomy time, successful tissue retrieval, en bloc resection, complete histologic resection, and emergency service visits. RESULTS: A total of 4270 participants were randomly assigned (2137 to CSP and 2133 to HSP). Eight patients (0.4%) in the CSP group and 31 (1.5%) in the HSP group had delayed bleeding (risk difference, -1.1% [95% CI, -1.7% to -0.5%]). Severe delayed bleeding was also lower in the CSP group (1 [0.05%] vs. 8 [0.4%] events; risk difference, -0.3% [CI, -0.6% to -0.05%]). Mean polypectomy time (119.0 vs. 162.9 seconds; difference in mean, -44.0 seconds [CI, -53.1 to -34.9 seconds]) was shorter in the CSP group, although successful tissue retrieval, en bloc resection, and complete histologic resection did not differ. The CSP group had fewer emergency service visits than the HSP group (4 [0.2%] vs. 13 [0.6%] visits; risk difference, -0.4% [CI, -0.8% to -0.04%]). LIMITATION: An open-label, single-blind trial. CONCLUSION: Compared with HSP, CSP for small colorectal polyps significantly reduces the risk for delayed postpolypectomy bleeding, including severe events. PRIMARY FUNDING SOURCE: Boston Scientific Corporation.


Assuntos
Pólipos do Colo , Humanos , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/efeitos adversos , Método Simples-Cego , Microcirurgia , Hemorragia Pós-Operatória/epidemiologia
3.
BMC Gastroenterol ; 22(1): 69, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35180851

RESUMO

BACKGROUND: Serum pepsinogen (PG) is recommended as a screening test for premalignant gastric lesions. However, real-world evidence demonstrating its applicability and equivalence between different test brands is limited. METHODS: Mass screening began in 2018 in a high-risk Taiwanese population after eradication of Helicobacter pylori, with the first stage of two PG tests (GastroPanel®, Helsinki, Finland and LZ-Test®, Tokyo, Japan) and the second stage of endoscopy. A positive test was defined as PG-I < 30 ng/mL or PG-I/II ratio < 3 for GastroPanel® and PG-I ≤ 70 ng/mL and PG-I/II ratio ≤ 3 for LZ-Test®. Index lesions included atrophic gastritis and intestinal metaplasia. Test performance was evaluated based on the participation rate, positivity rate, referral rate, positive predictive value (PPV), and the detection rate. RESULTS: Among 7616 eligible participants, 5117 (67.2%) received PG tests and 284 (5.6%) tested positive. Of those who tested positive, 105 (37.0%) underwent endoscopy. Overall PPVs for atrophic gastritis and intestinal metaplasia were 12.4% and 18.9%, respectively, with detection rates of 2.5 and 3.9 per 1000, respectively. Correlations of numerical measures between tests were high and the agreements of test results were substantial. The PPVs (16.3% vs. 16.3% and 23.8% vs. 21.3%, P = 1.00 and 0.71, respectively), detection rates (2.5 vs. 2.5 and 3.7 vs. 3.3 per 1000, P = 1.00 and 0.27, respectively), and the stage distributions of gastritis were all comparable, which were confirmed by multiple regression analyses. CONCLUSIONS: PG testing is effective for mass screening after eradication of H. pylori. Tests from different manufacturers, even using different analytical methods and cutoff criteria, can perform equivalently.


Assuntos
Gastrite Atrófica , Gastrite , Infecções por Helicobacter , Helicobacter pylori , Neoplasias Gástricas , Gastrite/diagnóstico , Gastrite Atrófica/patologia , Infecções por Helicobacter/diagnóstico , Infecções por Helicobacter/patologia , Humanos , Pepsinogênio A , Pepsinogênio C , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/patologia
4.
J Gastroenterol Hepatol ; 36(3): 671-679, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32671873

RESUMO

BACKGROUND AND AIM: The reliable method to stratify the gastric cancer risk after Helicobacter pylori eradication remains an elusive goal. METHODS: Mass eradication of H. pylori began in 2004 in a high-risk population. After eradication, a screening program involving first-stage serological tests (pepsinogen-I, pepsinogen-II, H. pylori immunoglobin G, and gastrin-17) and second-stage endoscopic examination was launched in 2015-2018. Index lesions included gastric cancer or extensive premalignant lesions. We evaluated the performance of the serological tests to "rule in" and "rule out" the risk based on positive and negative likelihood ratios, respectively. The methylation levels of microRNA-124a-3 in the stomach were measured to indicate genetic damage. RESULTS: Among 6512 invited subjects, 3895 (59.6%) participated. Both gastrin-17 and pepsinogen tests were normal in 3560 (91.4%) subjects; 206 (5.3%) gastrin-17 and 129 (3.3%) pepsinogen tests were abnormal. Years after eradication, the severity of gastritis had fallen greatly, and extensive premalignant lesions or gastric cancer frequently occurred in newly non-atrophic-appearing mucosa. Pepsinogen testing could moderately predict atrophic gastritis (positive likelihood ratio: 4.11 [95% confidence interval: 2.92-5.77]; negative likelihood ratio: 0.14 [0.10-0.19]). Gastrin-17 was not useful (0.66 and 1.20, respectively). However, pepsinogen testing poorly predicted the index lesions (2.04 [1.21-3.42] and 0.57 [0.34-0.95]). DNA methylation levels in the post-eradication mucosa were more discriminative for predicting index lesions (3.89 [2.32-6.54] and 0.25 [0.15-0.42]). CONCLUSIONS: After eradication, pepsinogen false-negative results become more frequent because histology is improved but genetic damage may persist. Direct testing for genetic damage offers better discrimination.


Assuntos
Gastrite/tratamento farmacológico , Gastrite/microbiologia , Infecções por Helicobacter , Helicobacter pylori , Medição de Risco/métodos , Neoplasias Gástricas/etiologia , Biomarcadores/metabolismo , Metilação de DNA , Reações Falso-Negativas , Feminino , Mucosa Gástrica/metabolismo , Gastrite/diagnóstico , Gastrite/genética , Humanos , Masculino , MicroRNAs/metabolismo , Pepsinogênio A/metabolismo , Risco , Fatores de Risco , Testes Sorológicos , Índice de Gravidade de Doença
5.
J Gastroenterol Hepatol ; 35(2): 233-240, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31408909

RESUMO

BACKGROUND AND AIM: The reported prevalence of Helicobacter pylori infection in Taiwan was 54.4% in 1992. An updated prevalence of H. pylori infection in asymptomatic adults is lacking in Taiwan. We aimed to assess the updated age-standardized prevalence of H. pylori infection in asymptomatic subjects and in patients with dyspepsia and to assess the accuracy of H. pylori stool antigen (HpSA) test for screening of H. pylori in Chinese population. METHODS: Asymptomatic adult subjects (N = 189) were screened for H. pylori infection using HpSA, serology, and 13 C-urea breath test (13 C-UBT) in 2016-2017. Adult patients with dyspepsia (N = 145) were screened for H. pylori using 13 C-UBT, HpSA, serology, rapid urease test, and histology during 2016-2018. Two types of HpSA, including the Diagnostec HpSA ELISA Kit (HpSA ELISA) and Rapid Test Kit (HpSA Rapid), were used in this study. Sensitivity, specificity, and accuracy of the HpSA tests were calculated using the 13 C-UBT as golden standard test. RESULTS: The unadjusted prevalence of H. pylori was 21.2% in asymptomatic adults and 37.9% in patients with dyspepsia (P < 0.001). The age-standardized prevalence of H. pylori was 28.9% in asymptomatic adults in Taiwan. Of the 334 patients included for analysis, the area under the curve of HpSA ELISA test was 0.978, and the optimal cutoff value of optical density was 0.03. The sensitivity, specificity, and accuracy of the HpSA ELISA were 0.929, 0.983, and 0.967, respectively. The sensitivity, specificity, and accuracy of the HpSA Rapid were 0.929, 0.958, and 0.949, respectively. CONCLUSIONS: The prevalence of H. pylori infection has decreased in Taiwan. HpSA test is an accurate tool for screening of H. pylori in Chinese population.


Assuntos
Antígenos de Bactérias , Gastrite/diagnóstico , Gastrite/microbiologia , Infecções por Helicobacter , Helicobacter pylori , Testes Imunológicos/métodos , Gastrite/epidemiologia , Helicobacter pylori/imunologia , Humanos , Prevalência , Taiwan/epidemiologia
6.
BMC Musculoskelet Disord ; 21(1): 752, 2020 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-33189156

RESUMO

BACKGROUND: Two parallel cannulated screws along with an anterior wire to construct a tension band is a popular approach in transverse patellar fractures. However, the optimal screw proximity, either deep or superficial screw placements, remains controversial. Hence, a new concept of the addition of a third screw to form a triangular configuration along with the original two parallel screws was proposed in this study. Therefore, the biomechanical effect of the additional third screw on the stability of the fractured patella was investigated with finite element (FE) simulation. METHODS: An FE knee model including the distal femur, proximal tibia, and fractured patella (type AT/OTA 34-C) was developed in this study. Four different screw configurations, including two parallel cannulated screws with superficial (5-mm proximity) and deep (10-mm proximity) placements and two parallel superficial screws plus a third deep screw, and two parallel deep screws plus a third superficial screw, with or without the anterior wire, were considered for the simulation. RESULTS: Results indicated that the addition of a third screw increased stability by reducing the dorsal gap opening when two parallel screws were deeply placed, particularly on the fractured patella without an anterior wire. However, the third screw was of little value when two parallel screws were superficially placed. In the existence of two deep parallel screws and the anterior wire, the third screw reduced the gap opening by 23.5% (from 1.15 mm to 0.88 mm) and 53.6% (from 1.21 mm to 0.61 mm) in knee flexion 45° and full extension, respectively. Furthermore, in the absence of the anterior wire, the third screw reduced the gap opening by 73.5% (from 2 mm to 0.53 mm) and 72.2% (from 1.33 mm to 0.37 mm) in knee flexion 45° and full extension, respectively. CONCLUSION: Based on the results, a third cannulated screw superficially placed (5-mm proximity) is recommended to increase stability and maintain contact of the fractured patella, fixed with two parallel cannulated screws deeply placed (10-mm proximity), particularly when an anterior wire was not used. Furthermore, the third screw deeply placed is not recommended in a fractured patella with two parallel superficial screws.


Assuntos
Fraturas Ósseas , Patela , Fenômenos Biomecânicos , Parafusos Ósseos , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Patela/diagnóstico por imagem , Patela/cirurgia
7.
Biomed Eng Online ; 18(1): 4, 2019 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-30606212

RESUMO

Prolonged static sitting in wheelchairs increases the risk of pressure ulcers. This exploratory study proposed three dynamic sitting techniques in order to reduce the risk of developing pressure ulcer during wheelchair sitting, namely lumbar prominent dynamic sitting, femur upward dynamic sitting, and lumbar prominent with femur upward dynamic sitting. The purpose of this study was to analyze the biomechanical effects of these three techniques on interface pressure. 15 able-bodied people were recruited as subjects to compare the aforementioned sitting techniques in a random order. All parameters, including dynamic contact area, dynamic average pressure, and dynamic peak pressure on backrest and seat were measured and compared. In result, when compared with lumbar prominent dynamic sitting, femur upward dynamic sitting and lumbar prominent with femur upward dynamic sitting appeared to yield significantly lower dynamic average and peak pressure on the back part of seat, and significantly higher dynamic average and peak pressure on the front part of seat. This study can serve as a reference point for clinical physicians or wheelchair users to identify a suitable dynamic sitting technique.


Assuntos
Região Lombossacral/fisiologia , Úlcera por Pressão/prevenção & controle , Postura Sentada , Adulto , Fenômenos Biomecânicos , Desenho de Equipamento , Ergonomia , Feminino , Humanos , Masculino , Pressão , Risco , Fatores de Tempo , Cadeiras de Rodas , Adulto Jovem
8.
BMC Musculoskelet Disord ; 20(1): 99, 2019 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-30832645

RESUMO

BACKGROUND: Cannulated screws with an anterior wire are currently used for managing transverse patellar fracture. However, the addition of anterior wiring with various types of screws via open surgery to increase the mechanical stability is yet to be determined. Hence, this study aimed to compare the mechanical behaviors of a fractured patella fixed with various screws types and at various screw locations with and without the anterior wire. The present study hypothesized that using the anterior wire reduces the fracture gap formation. METHODS: A finite element (FE) model containing a fractured patella fixed with various types of cannulated screws and anterior wiring was created in this study. Three types of screws, namely partial thread, full thread, and headless compression screws, and two screw depths, namely 5 and 10 mm away from the anterior surface of the patella, were included. The effect of the anterior wire was clarified by comparing the results of surgical fixation with and without the wire. Two magnitudes and two loading directions were used to simulate and examine the mechanical responses of the fractured patella with various fixation conditions during knee flexion/extension. RESULTS: Compared with partial thread and headless compression screws, the full thread screw increased the stability of the fractured patella by reducing fragment displacement, fracture gap formation, and contact pressure while increasing the contact area at the fracture site. Under 400-N in the direction 45°, the full thread screw with 5-mm placement reduced the gap formation by 86.7% (from 2.71 to 0.36 mm) and 55.6% (from 0. 81 to 0. 36 mm) compared with the partial thread screw with 10-mm placement, respectively without and with the anterior wire. CONCLUSION: The anterior wire along with the full thread screw is preferentially recommended for maintaining the surgical fixation of the fractured patella. Without the use of anterior wiring, the full thread screw with 5-mm placement may be considered as a less invasive alternative; however, simple screw fixation at a deeper placement (10 mm) is least recommended for the fixation of transverse patellar fracture.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Análise de Elementos Finitos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Patela/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Teste de Materiais/instrumentação , Teste de Materiais/métodos , Patela/diagnóstico por imagem , Patela/lesões , Suporte de Carga/fisiologia
9.
J Prosthet Dent ; 122(4): 376-382, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30948302

RESUMO

STATEMENT OF PROBLEM: A unidiameter abutment attached to a large-diameter implant has been reported to result in an unexpectedly high failure rate, inconsistent with the general understanding of dental implant mechanics. PURPOSE: The purpose of this finite element analysis study was to investigate the mechanical mechanism underlying these unexpected failures with the hypothesis that the cold welding or interference fit interface between abutment and implant increases the failure probability of a large-diameter implant system with a unidiameter abutment. MATERIAL AND METHODS: A conical implant system with different abutment gingival heights and implant diameters was analyzed for 3 contact conditions of the abutment-implant interface (bond and frictional coefficients of 0.3 and 0.7). A computer model was created using computed tomography images, and an oblique load of 100 N was applied to the abutment to determine the mechanical effect of the implant diameter and gingival height under the 3 contact conditions. RESULTS: When the abutment-implant interface was bonded, the peak stress of the abutment increased and that of the bone decreased with increasing implant diameter. When friction was applied to the abutment-implant interface, the peak stress of the implant, screw, and bone decreased with increasing implant diameter. Furthermore, the peak stress of the implant system and bone increased when the abutment gingival height increased under all contact conditions. CONCLUSIONS: Cold wielding or interference fit at the abutment-implant interface can prevent a screw fracture; however, it puts high stress on the unidiameter abutment neck when the implant diameter is increased. Screw loosening may lead to a slide between the abutment and implant, considerably increasing the stress of the screw. A system with a narrow diameter implant may cause an implant fracture rather than an abutment fracture when friction is applied to the abutment-implant interface.


Assuntos
Implantes Dentários , Fenômenos Biomecânicos , Dente Suporte , Projeto do Implante Dentário-Pivô , Análise do Estresse Dentário , Análise de Elementos Finitos , Estresse Mecânico
10.
Am J Gastroenterol ; 113(10): 1444-1457, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30171216

RESUMO

BACKGROUND: Whether concomitant therapy is superior to triple therapy of various treatment lengths for the first-line treatment of H. pylori remains controversial. The objective of this study is to compare the efficacy of concomitant therapy and triple therapy given for 5-14 days. METHODS: Randomized control trials (RCTs) comparing the efficacy of concomitant therapy for 5-14 days and proton pump inhibitor-amoxicillin-clarithromycin (PAC)-based triple therapy for 5-14 days in the first-line treatment of adult patients with H. pylori infection published from 1990 to January 2018 were searched from the PubMed, Cochrane Library, and Embase. Abstracts from international annual conferences were also searched. The primary and secondary outcomes were the eradication rate according to the intention-to-treat analysis and the adverse effects, respectively. Subgroup analyses were also performed according to treatment length. This study is registered with PROSPERO, number CRD42017081328. RESULTS: Of the 639 articles identified, 23 RCTs including 3305 patients in the concomitant therapy group and 3327 patients in the triple therapy group were eligible. Overall, concomitant therapy was superior to triple therapy [risk ratio (RR): 1.15; 95% confidence interval (CI): 1.09-1.21; p < 0.001]. However, there were significant heterogeneity (I2 = 74.0%, p < 0.001). In the subgroup analysis, 5-day concomitant therapy was superior to 5-day triple therapy (RR: 1.30; 95% CI: 1.04-1.62; p = 0.02), 5- or 7-day concomitant therapy was superior to 7-day triple therapy (RR: 1.16; 95% CI: 1.12-1.21; p < 0.001), and 5- or 7-, or 10- or 14-day concomitant therapy was superior to 10-day triple therapy (RR: 1.15; 95% CI: 1.08-1.23; p < 0.001). However, 5- or 10-day concomitant therapy was not superior to 14-day triple therapy (RR: 1.02; 95% CI: 0.89-1.16; p = 0.796). The frequency of adverse effects was significantly higher in concomitant therapy than triple therapy (RR: 1.19; 95% CI: 1.06-1.34; P = 0.004). CONCLUSIONS: Concomitant therapy given for 5 or 10 days was superior to 5- or 7-, or 10-day PAC-based triple therapy, but was not superior to 14-day triple therapy.


Assuntos
Antibacterianos/administração & dosagem , Erradicação de Doenças/métodos , Infecções por Helicobacter/tratamento farmacológico , Inibidores da Bomba de Prótons/administração & dosagem , Amoxicilina/administração & dosagem , Amoxicilina/efeitos adversos , Antibacterianos/efeitos adversos , Claritromicina/administração & dosagem , Claritromicina/efeitos adversos , Esquema de Medicação , Quimioterapia Combinada/métodos , Infecções por Helicobacter/epidemiologia , Infecções por Helicobacter/microbiologia , Infecções por Helicobacter/prevenção & controle , Helicobacter pylori/efeitos dos fármacos , Helicobacter pylori/isolamento & purificação , Humanos , Análise de Intenção de Tratamento , Metronidazol/administração & dosagem , Metronidazol/efeitos adversos , Inibidores da Bomba de Prótons/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Tinidazol/administração & dosagem , Tinidazol/efeitos adversos , Resultado do Tratamento
11.
Lancet ; 388(10058): 2355-2365, 2016 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-27769562

RESUMO

BACKGROUND: Whether concomitant therapy is superior to bismuth quadruple therapy or 14-day triple therapy for the first-line treatment of Helicobacter pylori infection remains poorly understood. We aimed to compare the efficacy and safety of 10-day concomitant therapy, 10-day bismuth quadruple therapy, and 14-day triple therapy in the first-line treatment of H pylori. METHODS: In this multicentre, open-label, randomised trial, we recruited adult patients (aged >20 years) with H pylori infection from nine medical centres in Taiwan. Patients who had at least two positive tests from the rapid urease test, histology, culture, or serology or who had a single positive 13C-urea breath test for gastric cancer screening were eligible for enrolment. Patients were randomly assigned (1:1:1) to either concomitant therapy (lansoprazole 30 mg, amoxicillin 1 g, clarithromycin 500 mg, and metronidazole 500 mg, all given twice daily) for 10 days; bismuth quadruple therapy (bismuth tripotassium dicitrate 300 mg four times a day, lansoprazole 30 mg twice daily, tetracycline 500 mg four times a day, and metronidazole 500 mg three times a day) for 10 days; or triple therapy (lansoprazole 30 mg, amoxicillin 1 g, and clarithromycin 500 mg, all given twice daily) for 14 days. A computer-generated permuted block randomisation sequence with a block size of 6 was used for randomisation, and the sequence was concealed in an opaque envelope until the intervention was assigned. Investigators were masked to treatment allocation. The primary outcome was the eradication frequency of H pylori with first-line therapy assessed in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01906879. FINDINGS: Between July 17, 2013, and April 20, 2016, 5454 patients were screened for eligibility. Of these, 1620 patients were randomly assigned in this study. The eradication frequencies were 90·4% (488/540 [95% CI 87·6-92·6]) for 10-day bismuth quadruple therapy, 85·9% (464/540 [82·7-88·6]) for 10-day concomitant therapy, and 83·7% (452/540 [80·4-86·6]) for 14-day triple therapy in the intention-to-treat analysis. 10-day bismuth quadruple therapy was superior to 14-day triple therapy (difference 6·7% [95% CI 2·7-10·7, p=0·001), but not 10-day concomitant therapy. 10-day concomitant therapy was not superior to 14-day triple therapy. The frequency of adverse events was 67% (358/533) in patients treated with 10-day bismuth quadruple therapy, 58% (309/535) in patients treated with 10-day concomitant therapy, and 47% (252/535) in patients treated with 14-day triple therapy. INTERPRETATION: Bismuth quadruple therapy is preferable to 14-day triple therapy in the first-line treatment in the face of rising prevalence of clarithromycin resistance. Concomitant therapy given for 10 days might not be optimum and a longer treatment length should be considered. FUNDING: National Taiwan University Hospital and Ministry of Science and Technology of Taiwan.


Assuntos
Antiácidos/administração & dosagem , Esquema de Medicação , Quimioterapia Combinada/estatística & dados numéricos , Infecções por Helicobacter/tratamento farmacológico , Helicobacter pylori/efeitos dos fármacos , Compostos Organometálicos/administração & dosagem , Amoxicilina/administração & dosagem , Amoxicilina/uso terapêutico , Antiácidos/uso terapêutico , Antibacterianos/administração & dosagem , Antibacterianos/uso terapêutico , Testes Respiratórios , Claritromicina/administração & dosagem , Claritromicina/uso terapêutico , Feminino , Humanos , Lansoprazol/administração & dosagem , Lansoprazol/uso terapêutico , Masculino , Metronidazol/administração & dosagem , Metronidazol/uso terapêutico , Pessoa de Meia-Idade , Compostos Organometálicos/uso terapêutico , Inibidores da Bomba de Prótons/administração & dosagem , Inibidores da Bomba de Prótons/uso terapêutico , Taiwan , Tetraciclina/administração & dosagem , Tetraciclina/uso terapêutico , Ureia/metabolismo
12.
Biomed Eng Online ; 16(1): 108, 2017 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-28851369

RESUMO

BACKGROUND: Reclining wheelchair users often add one or more sitting assistive devices to their wheelchairs, but the effect of these additional sitting assistive devices on the risk of pressure ulcers has rarely been investigated. This study examined the four modes of reclining wheelchair without and with different sitting assistive devices, namely the back reclined mode, the lumbar support with back reclined mode, the femur upward with back reclined mode, and the lumbar support with femur upward with back reclined mode, in terms of their effects on human-wheelchair interface pressure. METHODS: This study recruited 16 healthy participants to undergo the aforementioned four modes in random order and have their human-wheelchair interface pressure measured. The initial setting of experimental reclining wheelchair backrest was pushed backward to reach a 150° recline. The data on interface pressure were collected for 5 s while the participant maintained a stable sitting position. The contact area, average pressure, and peak pressure on the back area, ischial area, and femur area were recorded and calculated. RESULTS: Among all tested modes, the lumbar support with femur upward with back reclined mode provided the most significant reduction in stress load on the ischial area (P ≤ 0.010) and shifted part of the load to the femur area (P ≤ 0.009). CONCLUSIONS: This study quantified the effects of and differences between various reclining wheelchair-sitting assistive device combination modes. These findings are useful for the decision-making processes of rehabilitation physicians, wheelchair users, and manufacturers.


Assuntos
Postura , Pressão , Cadeiras de Rodas , Desenho de Equipamento , Feminino , Humanos , Masculino , Adulto Jovem
13.
Int Orthop ; 41(7): 1471-1480, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28120001

RESUMO

INTRODUCTION: Fracture impaction is a surgical technique used to support the fractured humerus with locking plate or intramedullary nail when treating proximal humeral fractures. However, few studies have investigated the mechanical difference between fracture impaction with locking plate and with intramedullary nail. The mechanism of fracture impaction to increase stability is still unclear. The aim of this study was to use numerical methods to compare the biomechanical effect of treating proximal humeral fracture. METHODS: Six different humerus models, including intact and fractured humeri with various fixation patterns were used in this study. Fracture impaction was simulated by moving the distal fragment of the humeral shift upwards directly until touching the inferior surface of the proximal fragment. We also considered both poor- and normal-quality bone in the simulation. RESULTS: Results confirmed that fracture impaction increases fracture stabilityand decreases peak stress in both implant and bone. Also, fracture impaction and plating with medial shift of the humeral shaft provides the highest stability. The metallic implant shared loading with the bone in the impacted models, while implants sustained all the loading alone in the nonimpacted models. CONCLUSIONS: Based on the results, the technique of fracture impaction is suggested for both nail and plate to reduce stresses on bone and implants and to increase structural stability. Furthermore, impaction with medial shift of the humeral shaft with plate is found to achieve the highest stability when treating proximal humeral fractures.


Assuntos
Pinos Ortopédicos/efeitos adversos , Placas Ósseas/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Fraturas do Ombro/cirurgia , Fenômenos Biomecânicos , Simulação por Computador , Fixação Intramedular de Fraturas/efeitos adversos , Humanos
14.
BMC Musculoskelet Disord ; 17(1): 496, 2016 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-27938365

RESUMO

BACKGROUND: Prolonged static sitting in a wheelchair is associated with an increased risk of lower back pain. The wheelchair seating system is a key factor of this risk because it affects spinal loading in the sitting position. In this study, 7 dynamic sitting strategies (DSSs) are examined: lumbar prominent dynamic sitting (LPDS), back reclined dynamic sitting (BRDS), femur upward dynamic sitting (FUDS), lumbar prominent with back reclined dynamic sitting (LBDS), lumbar prominent with femur upward dynamic sitting (LFDS), back reclined with femur upward dynamic sitting (BFDS), and lumbar prominent with back reclined with femur upward dynamic sitting (LBFDS). The objective of this study was to analyze the biomechanical effects of these sitting strategies on lumbar-pelvic angles. METHODS: Twenty able-bodied participants were recruited for the study. All participants performed LPDS, BRDS, FUDS, LBDS, LFDS, BFDS, and LBFDS in a random order. All lumbar-pelvic angle parameters, including the static lumbar angle, static pelvic angle, lumbar range of motion, and pelvic range of motion were measured and compared. RESULTS: Results show that LBDS and LBFDS enabled the most beneficial lumbar movements, although the difference between the 2 strategies was nonsignificant. BRDS and BFDS enabled the most beneficial pelvic movements, although the difference between the 2 strategies was nonsignificant. Among all the upright DSSs, LPDS and LFDS enabled the most beneficial lumbar and pelvic movements, although no significant difference was observed between these 2 strategies. CONCLUSIONS: We identified the effects and differences among 7 DSSs on lumbar-pelvic angles. Wheelchair users can choose the most suitable DSS that meets their needs. These findings may serve as a reference for practicing physicians or wheelchair users to choose an appropriate dynamic wheelchair seating system. TRIAL REGISTRATION: ISRCTN12389808 , 18th November 2016, retrospectively registered.


Assuntos
Dor Lombar/prevenção & controle , Região Lombossacral/anatomia & histologia , Ossos Pélvicos/anatomia & histologia , Postura , Cadeiras de Rodas/efeitos adversos , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Dor Lombar/etiologia , Masculino , Amplitude de Movimento Articular , Adulto Jovem
15.
Biomed Eng Online ; 14: 14, 2015 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-25880921

RESUMO

BACKGROUND: Back pain is a common complication of wheelchair-bound elderly people. Seating system is a key factor that influences spinal curvature, back muscle activation, interface pressure, and comfortability. A seating system can maintain lumbar lordosis, lower back muscle activity, and decrease ischial tuberosities pressure, which reduces spinal load and directly influences sitting comfort. Our previous study has confirmed that backward thoracic support showed a relatively higher lumbar lordosis and lower back muscle activity. This study intends to evaluate the influence of backward thoracic support on interface pressure and subjective discomfort. METHODS: In this study, 18 elderly men were recruited to participate in a random comparison involving 4 sitting postures. These postures comprised relaxed slouching, flat back support, prominent lumbar support, and backward thoracic support sitting. All parameters, including interface pressure (total contact area, average pressure, and peak pressure on backrest and seat) and subjective discomfort (upper-back, mid-back, lower-back, buttocks, and thighs) were measured and compared. RESULTS: The results showed that compared with other sitting postures, backward thoracic support sitting significantly reduced average pressure and peak pressure on seat and increased average pressure and peak pressure on backrest. Concurrently, subjective discomfort in the upper-back, mid-back, lower-back, and buttocks were reduced. CONCLUSIONS: The results confirmed that backward thoracic support can maintain favorable wheelchair sitting posture, thereby preventing or reducing the risks of back pain. However, this study was no evaluations on shear forces on butts and neck postures. Future studies investigating shear forces on butts and neck postures are required.


Assuntos
Cadeiras de Rodas , Idoso , Idoso de 80 Anos ou mais , Antropometria , Dor nas Costas/fisiopatologia , Dor nas Costas/prevenção & controle , Nádegas , Desenho de Equipamento , Ergonomia , Humanos , Masculino , Músculo Esquelético/fisiopatologia , Cervicalgia/fisiopatologia , Cervicalgia/prevenção & controle , Postura , Pressão/efeitos adversos , Coluna Vertebral/fisiopatologia
16.
Endoscopy ; 46(3): 190-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24573730

RESUMO

BACKGROUND AND STUDY AIMS: Carbon dioxide (CO2) insufflation during colonoscopy can significantly decrease abdominal pain and bloating after the procedure, but its impact on the frequency and duration of toilet use remains unknown. The aim of this study was to assess the impact of CO2 insufflation on toilet use after screening colonoscopy. METHODS: From 138 average-risk individuals who underwent screening colonoscopy during March to August 2013, 120 were enrolled and randomized to receive either CO2 or air insufflation at colonoscopy. Both the colonoscopist and participant were blinded to the type of gas used. Abdominal pain and distension were assessed using a visual analog scoring system. The frequency and duration of toilet visits during a 2-hour postcolonoscopy period were recorded using a radiofrequency identification system. RESULTS: Baseline characteristics were similar in both groups in terms of age, sex, and procedure time. In the 2 hours after colonoscopy, 50 participants (83 %) in the air group and 18 participants (30 %) in the CO2 group (P < 0.001) used the toilet at least once. The mean (± SD) duration of each toilet visit was 5.93 ±â€Š4.65 minutes in the air group and 1.53 ±â€Š2.84 minutes in the CO2 group (P < 0.001). The abdominal discomfort score was lower in the CO2 group than in the air group both at the end of the colonoscopy (P < 0.001) and 2 hours later (P < 0.001). CONCLUSION: Insufflation with CO2 can significantly reduce abdominal discomfort and toilet use after colonoscopy. Use of this technique may help reduce patient burden and allow more efficient use of space in the endoscopy unit.


Assuntos
Dióxido de Carbono , Colonoscopia/métodos , Insuflação/métodos , Banheiros/estatística & dados numéricos , Dor Abdominal/etiologia , Idoso , Ar , Colonoscopia/efeitos adversos , Método Duplo-Cego , Feminino , Humanos , Insuflação/efeitos adversos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Fatores de Tempo
17.
Injury ; 54(12): 111097, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37845172

RESUMO

INTRODUCTION: Elastic nails have been widely used in the diaphyseal fracture fixation of long bones in adolescents. However, high complication rates have been reported in cases involving weights exceeding 55 kg. The existing nails are fabricated with different metals in clinical settings; however, the effect of the materials on the mechanical responses of the fractured bone remains unclear. Hence, the present study is conducted to compare the mechanical responses of typically used metals, namely titanium, stainless, and nickel-titanium, for elastic nails in the fixation of tibial diaphyseal fractures. MATERIAL AND METHODS: A sawbone tube is used to determine the contact force, which is developed after constraining the nail inside the narrow canal using different nail materials. Furthermore, a finite element (FE) model of the tibial diaphyseal fracture is developed to predict the fracture gap deformation based on different nail materials under axial compression and bending loads. The push-out force in the FE simulation is compared with that of a case without an end cap. RESULTS: In the sawbone tube, the results indicate that the contact force developed by the titanium nail is significantly higher than those developed by stainless and nickel-titanium nails. The contact forces developed by the titanium, stainless steel, and nickel- titanium nails are 385 (SD 34), 358 (SD 49), and 258 (SD 42) N, respectively. In the FE simulation, the titanium nail yields the highest push-out force when an end cap is not used, and the push-out forces in axial compression are 201, 183, and 87 N in the titanium, stainless, and nickel-titanium nails under axial compression, respectively. By contrast, the stainless nail yields the smallest gap deformation when an end cap is used. CONCLUSION: Results of the present study show that the end cap is an important factor affecting the mechanical responses of nails fabricated using different materials. Titanium nails are preferred when an end cap is not used, whereas stainless nails are preferred when an end cap is used.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas da Tíbia , Adolescente , Humanos , Fraturas do Fêmur/cirurgia , Titânio , Níquel , Pinos Ortopédicos , Fixação Intramedular de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos
18.
J Orthop Surg Res ; 18(1): 5, 2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36593454

RESUMO

BACKGROUND: A minimally invasive technique with various screw configurations without open surgery is currently used for the fixation of transverse patellar fractures. Percutaneous crossing screw configuration has been reported to have a good bone union rate in patellar fractures. However, the difference in mechanical stability of the fractured patella between different screw-included angles has not been fully investigated. Hence, this study aims to compare the mechanical stability of parallel and crossing screw fixations with different screw-included angles for the fixation of transverse patellar fractures during level walking. METHODS: A finite element knee model containing a patella with a transverse fracture is created. Two headless compression screws with different angles (0°, 30°, 60°, and 90°) are used to fix the fracture. The loading conditions of the knee joint during level walking are used to compare the stability of the fractured patella with different fixation screw configurations. RESULTS: The results indicate that the maximum fracture gap opening distance increased with an increase in the included angle. Two parallel screws yield the smallest gap distance among all screw configurations. The maximum gap opening distances at the anterior leading edge of the fractured patella with two parallel screws and two screws having an included angle of 90° are 0.73 mm and 1.31 mm, respectively, at 15% walking cycle. CONCLUSIONS: Based on these results, the superior performance of two parallel screws over crossing screw fixations in the fixation of transverse patellar fractures is established. Furthermore, the smaller the angle between the crossing screws, the better is the stability of the fractured patella.


Assuntos
Fraturas Ósseas , Traumatismos do Joelho , Humanos , Fixação Interna de Fraturas/métodos , Análise de Elementos Finitos , Parafusos Ósseos , Fraturas Ósseas/cirurgia , Patela/cirurgia , Fenômenos Biomecânicos
19.
Patient Saf Surg ; 16(1): 25, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907905

RESUMO

INTRODUCTION: Partial fibular osteotomy has been recognized as a surgical alternative to treat medial compartment osteoarthritis of the knee. Related peroneal neuropathies are of concern among the relatively few complications after this procedure. In our clinical practice, the osteotomy level has therefore been modified to avoid the above defects. However, a rare case of vascular injury was encountered. Herein we describe an accidental anterior tibial artery pseudoaneurysm as a rare technical complication after this corrective osteotomy. CASE PRESENTATION: A 55-year-old male visited our emergency room, presenting a painful swelling over his right anterolateral shin along with surrounding ecchymosis. Thirteen days ago, he just underwent a corrective fibular osteotomy over his right painful varus knee at our institute, and was discharged after an uneventful postoperative stay. Urgent angiography revealed an out-pouching vascular lesion, pseudoaneurysm, involving his right anterior tibial artery. Prompt endovascular repair with stent insertion and balloon compression successfully stopped the persistent extravasation from the injured artery. Follow-up angiography as well as outpatient review confirmed the regression of this lesion and associated symptoms without sequelae. CONCLUSION: Although corrective fibular osteotomy is a simple surgical procedure, it is not free of complications. The suggested osteotomized level in the pertinent literature predisposes patients to certain neuromuscular deficits, which could be avoided by the modified level of osteotomy. However, our case highlights surgeons' familiarity with certain risky neurovascular structures around the osteotomy site and corresponding technical considerations. A recent surgical history along with alarming symptoms/signs should arouse clinical suspicion, aid in timely identification and make appropriate interventions for potential vascular complications.

20.
J Pers Med ; 12(2)2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35207743

RESUMO

BACKGROUND AND OBJECTIVES: Vertebral compression fracture is a major health care problem worldwide due to its direct and indirect negative influence on health-related quality of life and increased health care costs. Although a percutaneous surgical intervention with balloon kyphoplasty or metal expansion, the SpineJack, along with bone cement augmentation has been shown to efficiently restore and fix the lost vertebral height, 21-30% vertebral body height loss has been reported in the literature. Furthermore, the effect of the augmentation approaches and the loss of body height on the biomechanical responses in physiological activities remains unclear. Hence, this study aimed to compare the mechanical behavior of the fractured lumbar spine with different restored body heights, augmentation approaches, and posterior fixation after kyphoplasty using the finite element method. Furthermore, different augmentation approaches with bone cement and bone cement along with the SpineJack were also considered in the simulation. MATERIALS AND METHODS: A numerical lumbar model with an incomplete burst fracture at L3 was used in this study. Two different degrees of restored body height, namely complete and incomplete restorations, after kyphoplasty were investigated. Furthermore, two different augmentation approaches of the fractured vertebral body with bone cement and SpineJack along with bone cement were considered. A posterior instrument (PI) was also used in this study. Physiological loadings with 400 N + 10 Nm in four directions, namely flexion, extension, lateral bending, and axial rotation, were applied to the lumbar spine with different augmentation approaches for comparison. RESULTS: The results indicated that both the bone cement and bone cement along with the SpineJack could support the fractured vertebral body to react similarly with an intact lumbar spine under identical loadings. When the fractured body height was incompletely restored, the peak stress in the L2-L3 disk above the fractured vertebral body increased by 154% (from 0.93 to 2.37 MPa) and 116% (from 0.18 to 0.39 MPa), respectively, in the annular ground substance and nucleus when compared with the intact one. The use of the PI could reduce the range of motion and facet joint force at the implanted levels but increase the facet joint force at the upper level of the PI. CONCLUSIONS: In the present study, complete restoration of the body height, as possible in kyphoplasty, is suggested for the management of lumbar vertebral fractures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA