Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Neurol Neurosurg Psychiatry ; 80(8): 900-3, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19336432

RESUMO

BACKGROUND: Most patients with acute vestibular syndrome have vestibular neuritis or labyrinthitis. Some harbour strokes that can only be differentiated on the basis of subtle eye movement findings, including nystagmus. Peripheral nystagmus should be enhanced by removal of visual fixation. Current bedside methods for removing fixation require expensive equipment or technical skill not routinely available. We sought to test a new method for blocking fixation. METHODS: Proof-of-concept study for a new bedside oculomotor diagnostic test using an established physiological measurement of eye movements (electro-oculography (EOG)) as the reference standard. We sampled unselected patients undergoing caloric testing (surrogate model for neuritis) in an academic vestibular clinic. During the brief (30-60 s) decay phase of caloric-induced peripheral vestibular nystagmus, we shone a penlight in the left eye while intermittently occluding the right. We assessed nystagmus intensity (slow-phase velocity) clinically in all subjects and quantified change in two exemplar cases. RESULTS: Caloric responses frequently decayed before the test was complete, and artefacts rendered many EOGs uninterpretable during the short decay period. A clinically evident increase in nystagmus was seen 18 times in 10 patients and corroborated by EOG in 15. In quantified cases, slow-phase velocity increased as expected (mean change +42%) with fixation blocked. CONCLUSION: The penlight-cover test could offer a low-cost, simple means of disrupting visual fixation in clinical settings where differentiating peripheral from central vestibular disorders is crucial, such as the emergency department. Prospective studies are needed to determine the test's utility for excluding dangerous central causes among patients with suspected peripheral lesions.


Assuntos
Nistagmo Fisiológico/fisiologia , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletroculografia , Feminino , Fixação Ocular , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Padrões de Referência , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA