Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sci Rep ; 12(1): 1256, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35075221

RESUMO

Toxicoepigenetics is an emerging field that studies the toxicological impact of compounds on protein expression through heritable, non-genetic mechanisms, such as histone post-translational modifications (hPTMs). Due to substantial progress in the large-scale study of hPTMs, integration into the field of toxicology is promising and offers the opportunity to gain novel insights into toxicological phenomena. Moreover, there is a growing demand for high-throughput human-based in vitro assays for toxicity testing, especially for developmental toxicity. Consequently, we developed a mass spectrometry-based proof-of-concept to assess a histone code screening assay capable of simultaneously detecting multiple hPTM-changes in human embryonic stem cells. We first validated the untargeted workflow with valproic acid (VPA), a histone deacetylase inhibitor. These results demonstrate the capability of mapping the hPTM-dynamics, with a general increase in acetylations as an internal control. To illustrate the scalability, a dose-response study was performed on a proof-of-concept library of ten compounds (1) with a known effect on the hPTMs (BIX-01294, 3-Deazaneplanocin A, Trichostatin A, and VPA), (2) classified as highly embryotoxic by the European Centre for the Validation of Alternative Methods (ECVAM) (Methotrexate, and All-trans retinoic acid), (3) classified as non-embryotoxic by ECVAM (Penicillin G), and (4) compounds of abuse with a presumed developmental toxicity (ethanol, caffeine, and nicotine).


Assuntos
Código das Histonas , Espectrometria de Massas , Processamento de Proteína Pós-Traducional , Teratogênicos/análise , Testes de Toxicidade/métodos , Humanos , Estudo de Prova de Conceito
2.
Eur J Pharm Biopharm ; 169: 134-143, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34634467

RESUMO

Peritoneal metastasis is an advanced cancer type which can be treated with pressurized intraperitoneal aerosol chemotherapy (PIPAC). Here, chemotherapeutics are nebulized under high pressure in the intraperitoneal (IP) cavity to obtain a better biodistribution and tumor penetration. To prevent the fast leakage of chemotherapeutics from the IP cavity, however, nebulization of controlled release formulations is of interest. In this study, the potential of the thermosensitive hydrogel Pluronic F127 to be applied by high pressure nebulization is evaluated. Therefore, aerosol formation is experimentally examined by laser diffraction and theoretically simulated by computational fluid dynamics (CFD) modelling. Furthermore, Pluronic F127 hydrogels are subjected to rheological characterization after which the release of fluorescent model nanoparticles from the hydrogels is determined. A delicate equilibrium is observed between controlled release properties and suitability for aerosolization, where denser hydrogels (20% and 25% w/v Pluronic F127) are able to sustain nanoparticle release up to 30 h, but cannot effectively be nebulized and vice versa. This is demonstrated by a growing aerosol droplet size and exponentially decreasing aerosol cone angle when Pluronic F127 concentration and viscosity increase. Novel nozzle designs or alternative controlled release formulations could move intraperitoneal drug delivery by high pressure nebulization forward.


Assuntos
Partículas e Gotas Aerossolizadas/farmacologia , Antineoplásicos/farmacologia , Absorção Peritoneal/efeitos dos fármacos , Neoplasias Peritoneais , Poloxâmero/farmacologia , Preparações de Ação Retardada/farmacologia , Composição de Medicamentos/métodos , Excipientes/farmacologia , Humanos , Hidrodinâmica , Hidrogéis/farmacologia , Nanopartículas/uso terapêutico , Nebulizadores e Vaporizadores , Neoplasias Peritoneais/secundário , Neoplasias Peritoneais/terapia , Distribuição Tecidual
3.
Forensic Sci Int Genet ; 38: 204-210, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30448528

RESUMO

The potential and current state-of-the-art of forensic SNP genotyping using nanopore sequencing was investigated with a panel of 16 tri-allelic single nucleotide polymorphisms (SNPs), multiplexing five samples per sequencing run. The sample set consisted of three single-source human genomic reference control DNA samples and two GEDNAP samples, simulating casework samples. The primers for the multiplex SNP-loci PCR were taken from a study which researched their value in a forensic setting using conventional single-base extension technology. Workflows for multiplexed Oxford Nanopore Technologies' 1D and 1D2 sequencing were developed that provide correct genotyping of most SNP loci. Loci that are problematic for nanopore sequencing were characterized. When such loci are avoided, nanopore sequencing of forensic tri-allelic SNPs is technically feasible.


Assuntos
Técnicas de Genotipagem/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Nanoporos , Polimorfismo de Nucleotídeo Único , Análise de Sequência de DNA , Alelos , Primers do DNA , Humanos , Reação em Cadeia da Polimerase Multiplex
4.
Sci Rep ; 9(1): 7341, 2019 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-31089203

RESUMO

The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.


Assuntos
Impressões Digitais de DNA/instrumentação , Genética Forense/instrumentação , Dispositivos Lab-On-A-Chip , Reação em Cadeia da Polimerase/instrumentação , DNA/análise , DNA/genética , Desenho de Equipamento , Humanos , Desnaturação de Ácido Nucleico , Silício/química
5.
Sci Rep ; 8(1): 9853, 2018 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-29959383

RESUMO

The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 µl each. Diluted reference DNA samples (1 ng-31 pg) were amplified on the µPCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62 pg. Occasional allelic dropouts were observed from 31 pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both µPCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17 minutes from as little as 125 pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis.


Assuntos
Impressões Digitais de DNA/normas , Genética Forense/normas , Marcadores Genéticos , Repetições de Microssatélites , Reação em Cadeia da Polimerase/métodos , Silício/química , Genótipo , Humanos
6.
Sci Rep ; 7: 41759, 2017 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-28155888

RESUMO

One of the latest developments in next generation sequencing is the Oxford Nanopore Technologies' (ONT) MinION nanopore sequencer. We studied the applicability of this system to perform forensic genotyping of the forensic female DNA standard 9947 A using the 52 SNP-plex assay developed by the SNPforID consortium. All but one of the loci were correctly genotyped. Several SNP loci were identified as problematic for correct and robust genotyping using nanopore sequencing. All these loci contained homopolymers in the sequence flanking the forensic SNP and most of them were already reported as problematic in studies using other sequencing technologies. When these problematic loci are avoided, correct forensic genotyping using nanopore sequencing is technically feasible.


Assuntos
Genética Forense , Técnicas de Genotipagem , Sequenciamento de Nucleotídeos em Larga Escala , Polimorfismo de Nucleotídeo Único , Alelos , Genética Forense/métodos , Frequência do Gene , Loci Gênicos , Humanos , Repetições de Microssatélites , Análise de Sequência de DNA
7.
Sci Rep ; 7(1): 17189, 2017 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-29215049

RESUMO

The growing interest in liquid biopsies for cancer research and cell-based non-invasive prenatal testing (NIPT) invigorates the need for improved single cell analysis. In these applications, target cells are extremely rare and fragile in peripheral circulation, which makes the genetic analysis very challenging. To overcome these challenges, cell stabilization and unbiased whole genome amplification are required. This study investigates the performance of four WGA methods on single or a limited number of cells after 24 hour of Streck Cell-Free DNA BCT preservation. The suitability of the DNA, amplified with Ampli1, DOPlify, PicoPLEX and REPLI-g, was assessed for both short tandem repeat (STR) profiling and copy number variant (CNV) analysis after shallow whole genome massively parallel sequencing (MPS). Results demonstrate that Ampli1, DOPlify and PicoPLEX perform well for both applications, with some differences between the methods. Samples amplified with REPLI-g did not result in suitable STR or CNV profiles, indicating that this WGA method is not able to generate high quality DNA after Streck Cell-Free DNA BCT stabilization of the cells.


Assuntos
Linfócitos B/metabolismo , Ácidos Nucleicos Livres/análise , Variações do Número de Cópias de DNA , Genoma Humano , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Repetições de Microssatélites , Técnicas de Amplificação de Ácido Nucleico/métodos , Linfócitos B/patologia , Feminino , Humanos , Gravidez , Preservação Biológica , Kit de Reagentes para Diagnóstico , Análise de Sequência de DNA/métodos , Análise de Célula Única/métodos
8.
Sci Rep ; 7(1): 3422, 2017 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-28611458

RESUMO

Whole genome amplification (WGA) has become an invaluable tool to perform copy number variation (CNV) detection in single, or a limited number of cells. Unfortunately, current WGA methods introduce representation bias that limits the detection of small CNVs. New WGA methods have been introduced that might have the potential to reduce this bias. We compared the performance of PicoPLEX DNA-Seq (Picoseq), DOPlify, REPLI-g and Ampli-1 WGA for aneuploidy screening and copy number analysis using shallow whole genome massively parallel sequencing (MPS), starting from single or a limited number of cells. Although the four WGA methods perform differently, they are all suited for this application.


Assuntos
Variações do Número de Cópias de DNA , Técnicas de Amplificação de Ácido Nucleico/métodos , Análise de Célula Única/métodos , Linhagem Celular Tumoral , Humanos , Técnicas de Amplificação de Ácido Nucleico/normas , Análise de Célula Única/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA