Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ultrason Imaging ; 46(2): 130-134, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38318708

RESUMO

Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes subharmonic signals from microbubble contrast agents for pressure estimation. Validation of the SHAPE technique relies on synchronous measurements of in vivo pressures using contrast microbubbles and a pressure catheter (reference standard). For the guidance and placement of pressure catheter in vivo, iodinated contrast is used with fluoroscopy. Therefore, during data acquisition for validation studies of the SHAPE technique, both contrast microbubbles and iodinated contrast are present simultaneously within the vasculature. This study aims to elucidate the effects of iodinated contrast (Visipaque, GE HealthCare) on subharmonic signal amplitude from contrast microbubbles (Definity, Lantheus Medical Imaging, Inc.). In an acrylic water tank, 0.06 mL of Definity and varied amounts of Visipaque (0.14, 0.43, 0.85, and 1.70 mL) were added to 425 mL of deionized water. Ultrasound scanning was performed with a SonixTablet scanner (BK Medical Systems) using optimized parameters for SHAPE with Definity (ftransmit/receive = 3.0/1.5 MHz; chirp down pulse). Subharmonic data was acquired and analyzed at 9 different incident acoustic outputs (n = 3). Results showed an increase in subharmonic signal amplitude from Definity microbubbles in the presence of 0.14 mL Visipaque by 2.8 ± 1.3 dB (p < .001), no change with 0.85 mL Visipaque (0.7 ± 1.2 dB; p = .09) and a decrease in subharmonic amplitude in the presence of 1.70 mL Visipaque by 1.9 ± 0.7 dB (p < .001). While statistically significant effect on subharmonic signal amplitude of Definity microbubbles was noted due to the mixture, the magnitude of the effect was minimal (~2.8 dB) and unlikely to impact in vivo SHAPE measurements.


Assuntos
Meios de Contraste , Fluorocarbonos , Ácidos Tri-Iodobenzoicos , Água , Ultrassonografia/métodos
2.
J Transl Med ; 21(1): 477, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37461108

RESUMO

Pulmonary arterial hypertension (PAH) is a multifactorial disease associated with the remodeling of pulmonary blood vessels. If left unaddressed, PAH can lead to right heart failure and even death. Multiple biological processes, such as smooth muscle proliferation, endothelial dysfunction, inflammation, and resistance to apoptosis, are associated with PAH. Increasing evidence suggests that epigenetic factors play an important role in PAH by regulating the chromatin structure and altering the expression of critical genes. For example, aberrant DNA methylation and histone modifications such as histone acetylation and methylation have been observed in patients with PAH and are linked to vascular remodeling and pulmonary vascular dysfunction. In this review article, we provide a comprehensive overview of the role of key epigenetic targets in PAH pathogenesis, including DNA methyltransferase (DNMT), ten-eleven translocation enzymes (TET), switch-independent 3A (SIN3A), enhancer of zeste homolog 2 (EZH2), histone deacetylase (HDAC), and bromodomain-containing protein 4 (BRD4). Finally, we discuss the potential of multi-omics integration to better understand the molecular signature and profile of PAH patients and how this approach can help identify personalized treatment approaches.


Assuntos
Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Humanos , Hipertensão Arterial Pulmonar/genética , Medicina de Precisão , Hipertensão Pulmonar/patologia , Fatores de Transcrição/metabolismo , Proteínas Nucleares/metabolismo , Artéria Pulmonar/metabolismo , Artéria Pulmonar/patologia , Epigênese Genética , Remodelação Vascular/genética , Proteínas de Ciclo Celular/genética
3.
J Magn Reson Imaging ; 58(4): 1191-1197, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36744579

RESUMO

BACKGROUND: Focal nodular hyperplasia (FNH) and hepatic adenoma (HA) are two common benign liver lesions with different management options. In particular, resection is considered for large HA lesions to avoid possible bleeding complications or rarely malignant degeneration. PURPOSE: To determine whether early enhancement of a draining hepatic vein (EDHV) and absence of perilesional enhancement (PLE) on arterial phase MR images are useful for distinguishing FNH from HA. STUDY TYPE: Retrospective. POPULATION: A total of 34 patients: 16 with FNH and 18 with HA lesions. FIELD STRENGTH/SEQUENCE: A1.5 T, axial T1 fat-suppressed arterial postcontrast. ASSESMENT: Four abdominal radiologists blinded to pathologic diagnosis assessed for the presence or absence of EDHV in association with the lesion, definitively characterized by pathology. This was considered present if contrast could be identified in a hepatic vein contiguous with the lesion in question. Secondarily, PLE was evaluated. STATISTICAL TESTS: Fleiss's multirater kappa statistic, Chi-squared statistic, Phi-coefficient. Significance level P < 0.05. RESULTS: Considering all observations obtained from the four readers, an EDHV was identified with FNH 48.5% of the time. EDHV was seen with HA in 8.8% of cases. PLE was seen with significantly greater frequency in HA. The presence of an EDHV was associated with the absence of PLE. DATA CONCLUSION: In a lesion that may be either an FNH or HA, confident identification on arterial phase images of an EDHV should lead the reader to favor FNH, while the presence PLE should dissuade the reader from FNH. EVIDENCE LEVEL: 4. TECHNICAL EFFICACY: Stage 2.


Assuntos
Adenoma de Células Hepáticas , Hiperplasia Nodular Focal do Fígado , Neoplasias Hepáticas , Humanos , Hiperplasia Nodular Focal do Fígado/diagnóstico por imagem , Hiperplasia Nodular Focal do Fígado/patologia , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Veias Hepáticas , Meios de Contraste , Adenoma de Células Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Diagnóstico Diferencial
4.
J Appl Clin Med Phys ; 24(5): e13938, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36995917

RESUMO

Reject rate analysis is considered an integral part of a diagnostic radiography quality control (QC) program. A rejected image is a patient radiograph that was not presented to a radiologist for diagnosis and that contributes unnecessary radiation dose to the patient. Reject rates that are either too high or too low may suggest systemic department shortcomings in QC mechanisms. Due to the lack of standardization, reject data often cannot be easily compared between radiography systems from different vendors. The purpose of this report is to provide guidance to help standardize data elements that are required for comprehensive reject analysis and to propose data reporting and workflows to enable an effective and comprehensive reject rate monitoring program. Essential data elements, a proposed schema for classifying reject reasons, and workflow implementation options are recommended in this task group report.


Assuntos
Radiografia , Humanos , Controle de Qualidade , Padrões de Referência
5.
J Ultrasound Med ; 41(7): 1781-1789, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34724241

RESUMO

OBJECTIVES: Subharmonic aided pressure estimation (SHAPE) has been shown effective for noninvasively measuring hydrostatic fluid pressures in a variety of clinical applications. The objective of this study was to explore potential improvements in SHAPE sensitivity using monodisperse microbubbles. METHODS: Populations of monodisperse microbubbles were created using a commercially available microfluidics device (Solstice Pharmaceuticals). Size distributions were assessed using a Coulter Counter and stability of the distribution following fabrication was evaluated over 24 hours. Attenuation of the microbubble populations from 1 to 10 MHz was then quantified using single element transducers to identify each formulation's resonance frequency. Frequency spectra over increasing driving amplitudes were investigated to determine the nonlinear phases of subharmonic signal generation. SHAPE sensitivity was evaluated in a hydrostatic pressure-controlled water bath using a Logiq E10 scanner (GE Healthcare). RESULTS: Monodisperse lipid microbubble suspensions ranging from 2.4 to 5.3 µm in diameter were successfully created and they showed no discernable change in size distribution over 24 hours following activation. Calculated resonance frequencies ranged from 2.1 to 6.3 MHz and showed excellent correlation with microbubble diameter (R2 > 0.99). When investigating microbubble frequency response, subharmonic signal occurrence was shown to begin at 150 kPa peak negative pressure, grow up to 225 kPa, and saturate at approximately 250 kPa. Using the Logiq E10, monodisperse bubbles demonstrated a SHAPE sensitivity of -0.17 dB/mmHg, which was nearly twice the sensitivity of the commercial polydisperse microbubble currently being used in clinical trials. CONCLUSIONS: Monodisperse microbubbles have the potential to greatly improve the sensitivity of SHAPE for the noninvasive measurement of hydrostatic pressures.


Assuntos
Meios de Contraste , Microbolhas , Determinação da Pressão Arterial , Humanos , Transdutores , Ultrassonografia
6.
J Appl Clin Med Phys ; 23(7): e13664, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35699199

RESUMO

There is no current authoritative accounting of the number of clinical imaging physicists practicing in the United States. Information about the workforce is needed to inform future efforts to secure training pathways and opportunities. In this study, the AAPM Diagnostic Demand and Supply Projection Working Group collected lists of medical physicists from several state registration and licensure programs and the Conference of Radiation Control Program Directors (CRCPD) registry. By cross-referencing individuals among these lists, we were able to estimate the current imaging physics workforce in the United States by extrapolating based on population. The imaging physics workforce in the United States in 2019 consisted of approximately 1794 physicists supporting diagnostic X-ray (1073 board-certified) and 934 physicists supporting nuclear medicine (460 board-certified), with a number of individuals practicing in both subfields. There were an estimated 235 physicists supporting nuclear medicine exclusively (150 board-certified). The estimated total workforce, accounting for overlap, was 2029 medical physicists. These estimates are in approximate agreement with other published studies of segments of the workforce.


Assuntos
Radioterapia (Especialidade) , Diagnóstico por Imagem , Física Médica/educação , Humanos , Física , Radioterapia (Especialidade)/educação , Radiografia , Estados Unidos , Recursos Humanos
7.
Skeletal Radiol ; 50(7): 1399-1409, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33404668

RESUMO

OBJECTIVE: To evaluate adults with history of Osgood Schlatter disease (OSD) for imaging features of lateral patellofemoral maltracking. METHODS: In a span of four years, 10,181 unique non-contrast knee MRIs were performed on patients aged 20-50. Patients with acute trauma, prior surgery, and synovial pathologies were excluded. 171 exams had imaging findings of OSD, and an age-matched control group of 342 patients without OSD was randomly selected. Two radiologists retrospectively reviewed MRIs for features of lateral patellofemoral maltracking. Maltracking was defined as edema in superolateral Hoffa's fat or a tibial tuberosity-trochlear groove (TT-TG) distance ≥20 mm with either patellar tilt/translation. Binomial logistic regression identified predictors of maltracking in OSD. Optimal TT-TG distance to indicate maltracking was determined by receiver operating characteristic curve. RESULTS: 59% (101/171) of the knees with OSD showed findings of maltracking, with patella alta, trochlear dysplasia, and quadriceps tendinosis as significant predictors of maltracking (p < 0.001). Patellofemoral chondrosis was present in 63% (107/171), with maltracking contributing to higher grade chondrosis more so than increasing age (OR 8.4 versus 1.07). 13 mm was the optimal cut-off TT-TG distance to indicate maltracking (sensitivity 83%, specificity 80%). The prevalence of maltracking in the control group was 15% (p < 0.001 compared with the OSD group). CONCLUSION: Adults with sequelae of OSD are at high risk of maltracking and are likely to develop patellofemoral chondrosis. A lower threshold for identifying maltracking patients, including a lower cut-off TT-TG distance can help identify those at risk. Radiologists should maintain a high index of suspicion for maltracking in adults with OSD to guide clinical intervention.


Assuntos
Instabilidade Articular , Osteocondrose , Articulação Patelofemoral , Adulto , Humanos , Imageamento por Ressonância Magnética , Patela , Articulação Patelofemoral/diagnóstico por imagem , Prevalência , Estudos Retrospectivos , Tíbia
8.
AJR Am J Roentgenol ; 213(6): 1267-1273, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31532256

RESUMO

OBJECTIVE. The purpose of this study was to evaluate the utility of T1- and T2-weighted MRI signal-intensity ratios and signal-intensity SDs of renal lesions to determine the feasibility of distinguishing between simple cysts, hemorrhagic renal cysts, clear cell renal cell carcinoma (RCC), and papillary RCC. MATERIALS AND METHODS. Pathology records of 53 cases of papillary RCCs between 1 and 5 cm in size were included. Thirty-eight pathology-proven clear cell RCCs, 54 simple renal cysts seen on abdominal MRI, and 59 hemorrhagic renal cysts seen on abdominal MRI were identified. Lesion location and size, T1- and T2-weighted signal intensity, and corresponding SD values for each renal lesion and psoas muscle (from which lesion-to-muscle ratios were calculated) were collected. RESULTS. Analysis revealed a statistically significant difference (p < 0.001) in T1-weighted lesion-to-muscle signal-intensity ratios between simple cysts (mean ± standard error, 0.54 ± 0.05), clear cell RCCs (0.86 ± 0.06), papillary RCCs (1.17 ± 0.05), and hemorrhagic renal cysts (1.95 ± 0.04). The T2-weighted lesion-to-muscle signal-intensity ratios showed a statistically significant difference between all lesion types (p < 0.02) except between hemorrhagic renal cysts and papillary RCCs, where the difference approached significance (p = 0.075). ROC analysis showed an optimal cutoff of T1-weighted lesion-to-muscle signal-intensity ratio of 1.39 to differentiate hemorrhagic cysts (above this value) from RCCs (below this value). Corresponding sensitivity and specificity were 91.2% and 74.6%, respectively. CONCLUSION. T1-weighted lesion-to-muscle signal-intensity ratio is a useful measure to discriminate mildly hyperintense RCCs from more hyperintense hemorrhagic cysts when contrast enhancement is unavailable.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
J Ultrasound Med ; 36(1): 3-11, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27943411

RESUMO

OBJECTIVES: Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency ie, fo and receiving at half the transmit frequency (ie, fo /2). Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of the microbubbles and the ambient pressure change. METHODS: Eight waveforms with different envelopes were optimized with respect to acoustic power at which the SHAPE study is most sensitive. The study was run with four input transmit cycles, first in vitro and then in vivo in three canines to select the waveform that achieved the best sensitivity for detecting changes in portal pressures using SHAPE. A Logiq 9 scanner with a 4C curvi-linear array was used to acquire 2.5 MHz radio-frequency data. Scanning was performed in dual imaging mode with B-mode imaging at 4 MHz and a SHI contrast mode transmitting at 2.5 MHz and receiving at 1.25 MHz. Sonazoid, which is a lipid stabilized gas filled bubble of perfluorobutane, was used as the contrast agent in this study. RESULTS: A linear decrease in subharmonic amplitude with increased pressure was observed for all waveforms (r from -0.77 to -0.93; P < .001) in vitro. There was a significantly higher correlation of the SHAPE gradient with changing pressures for the broadband pulses as compared to the narrowband pulses in both in vitro and in vivo results. The highest correlation was achieved with a Gaussian windowed binomial filtered square wave with an r-value of -0.95. One of the three canines was eliminated for technical reasons, while the other two produced very similar results to those obtained in vitro (r from -0.72 to -0.98; P <.01). The most consistent in vivo results were achieved with the Gaussian windowed binomial filtered square wave (r = -0.95 and -0.96). CONCLUSIONS: Using this waveform is an improvement to the existing SHAPE technique (where a square wave was used) and should make SHAPE more sensitive for noninvasively determining portal hypertension.


Assuntos
Pressão na Veia Porta/fisiologia , Veia Porta/diagnóstico por imagem , Veia Porta/fisiologia , Ultrassonografia/métodos , Animais , Meios de Contraste , Cães , Compostos Férricos , Aumento da Imagem/métodos , Ferro , Microbolhas , Óxidos , Imagens de Fantasmas , Reprodutibilidade dos Testes
11.
J Vasc Interv Radiol ; 27(4): 593-600, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26948994

RESUMO

PURPOSE: To investigate changes in radiation dose and image quality using phantoms and hepatic embolization procedures performed with a new image processing technology (ClarityIQ) for a single-plane flat-detector-based interventional fluoroscopy system. MATERIALS AND METHODS: Phantom study was performed using acrylic sheets simulating different patient sizes. Air kerma rates (AKRs) were compared for different fluoroscopy modes and magnification modes without and with ClarityIQ. Repeat hepatic embolization procedures performed on the same lobe of the liver in the same patient by the same interventional radiologist between January 2013 and July 2014 without and with ClarityIQ were evaluated retrospectively. This included treatment of 33 hepatic lobes in 26 patients. Cumulative air kerma (CAK), kerma-area product (KAP), and factors affecting radiation dose were extracted from study metadata and compared. Blinded randomized image quality review was performed on arteriograms using a five-point scale. RESULTS: The phantom study revealed a significantly lower AKR (P < .005) with ClarityIQ. Repeated-measures analysis revealed a significant effect of ClarityIQ (P ≤ .001) on CAK and KAP, with reductions ranging between 9% and 85% (median, 67%) and between 5% and 89% (median, 75%), respectively, on a case-by-case basis. Mean reductions in CAK and KAP were 279 mGy and 134,030 mGy·cm(2), respectively. Image quality review scores were significantly lower (P ≤ .001) with ClarityIQ, effecting visualization of tumor vasculature and appearance of noise texture. CONCLUSIONS: ClarityIQ resulted in radiation dose reduction in the phantom study and in the hepatic embolization procedures, but with a decrease in subjective perceptions of image quality.


Assuntos
Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Melanoma/terapia , Imagens de Fantasmas , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/instrumentação , Radiografia Intervencionista/métodos , Neoplasias Uveais/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Melanoma/diagnóstico por imagem , Melanoma/secundário , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Software , Resultado do Tratamento
12.
AJR Am J Roentgenol ; 207(2): 274-81, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27223688

RESUMO

OBJECTIVE: Breast cancer is the most frequent type of cancer among women (25% of all cancers). The angiogenic process that fuels the growth of tumors is a potential early indicator for differentiating between malignant and benign tumors. Recently, the use of microbubble-based contrast agents combined with ultrasound has allowed the development of contrast agent-specific imaging modes that provide visualization of tumor neovascularity. CONCLUSION: Contrast-enhanced Doppler, harmonic, and subharmonic imaging are some of the imaging modes that have been investigated for visualizing and quantifying the vascularity in breast tumors.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Neoplasias da Mama/patologia , Meios de Contraste , Feminino , Humanos , Microbolhas
13.
J Ultrasound Med ; 35(9): 1839-47, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27388814

RESUMO

OBJECTIVES: Different methods for obtaining tumor neovascularity parameters based on immunohistochemical markers were compared to contrast-enhanced subharmonic imaging (SHI). METHODS: Eighty-five athymic nude female rats were implanted with 5 × 10(6) breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) was injected, and SHI was performed using a modified Sonix RP scanner (Analogic Ultrasound, Richmond, British Columbia, Canada) with a L9-4 linear array (transmitting/receiving frequencies, 8/4 MHz). Afterward, specimens were stained for endothelial cells (CD31), vascular endothelial growth factor (VEGF), and cyclooxygenase 2 (COX-2). Tumor neovascularity was assessed in 4 different ways using a histomorphometry system (×100 magnification: (1) over the entire tumor; (2) in small sub-regions of interest (ROIs); (3) in the tumor periphery and centrally; and (4) in 3 regions of maximum marker expression (so-called hot spots). Results from specimens and from SHI were compared by linear regression. RESULTS: Fifty-four rats (64%) showed tumor growth, and 38 were successfully imaged. Subharmonic imaging depicted the tortuous morphologic characteristics of tumor neovessels and delineated small areas of necrosis. The immunohistochemical markers did not correlate with SHI measures over the entire tumor area or over small sub-ROIs (P > .18). However, when the specimens were subdivided into central and peripheral regions, COX-2 and VEGF correlated with SHI in the periphery (r = -0.42; P = .005; and r = -0.32; P = .049, respectively). CONCLUSIONS: When comparing quantitative contrast measures of tumor neovascularity to immunohistochemical markers of angiogenesis in xenograft models, ROIs corresponding to the biologically active region should be used to account for tumor heterogeneity.


Assuntos
Neoplasias da Mama/irrigação sanguínea , Meios de Contraste , Aumento da Imagem/métodos , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/metabolismo , Ultrassonografia , Animais , Biomarcadores/metabolismo , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Ciclo-Oxigenase 2/metabolismo , Modelos Animais de Doenças , Células Endoteliais/patologia , Feminino , Camundongos Nus , Ratos , Fator A de Crescimento do Endotélio Vascular/metabolismo
15.
Radiol Cardiothorac Imaging ; 6(1): e230153, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358329

RESUMO

Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.


Assuntos
Compostos Férricos , Ferro , Microbolhas , Óxidos , Humanos , Coração , Ventrículos do Coração
16.
Radiology ; 268(2): 581-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23525208

RESUMO

PURPOSE: To compare subharmonic aided pressure estimation (SHAPE) with pressure catheter-based measurements in human patients with chronic liver disease undergoing transjugular liver biopsy. MATERIALS AND METHODS: This HIPAA-compliant study had U.S. Food and Drug Administration and institutional review board approval, and written informed consent was obtained from all participants. Forty-five patients completed this study between December 2010 and December 2011. A clinical ultrasonography (US) scanner was modified to obtain SHAPE data. After transjugular liver biopsy with pressure measurements as part of the standard of care, 45 patients received an infusion of a microbubble US contrast agent and saline. During infusion, SHAPE data were collected from a portal and hepatic vein and were compared with invasive measurements. Correlations between data sets were determined by using the Pearson correlation coefficient, and statistical significance between groups was determined by using the Student t test. RESULTS: The 45 study patients included 27 men and 18 women (age range, 19-71 years; average age, 55.8 years). The SHAPE gradient between the portal and hepatic veins was in good overall agreement with the hepatic venous pressure gradient (HVPG) (R = 0.82). Patients at increased risk for variceal hemorrhage (HVPG ≥ 12 mm Hg) had a significantly higher mean subharmonic gradient than patients with lower HVPGs (1.93 dB ± 0.61 [standard deviation] vs -1.47 dB ± 0.29, P < .001), with a sensitivity of 100% and a specificity of 81%, indicating that SHAPE may be a useful tool for the diagnosis of clinically important portal hypertension. CONCLUSION: Preliminary results show SHAPE to be an accurate noninvasive technique for estimating portal hypertension.


Assuntos
Veias Hepáticas , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/fisiopatologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/fisiopatologia , Adulto , Idoso , Biópsia , Doença Crônica , Meios de Contraste , Feminino , Compostos Férricos , Humanos , Ferro , Masculino , Pessoa de Meia-Idade , Óxidos , Projetos Piloto , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia de Intervenção
17.
AJR Am J Roentgenol ; 200(1): 142-5, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255754

RESUMO

OBJECTIVE: The purpose of this study was to extract exposure parameters and dose-relevant indexes of CT examinations from information embedded in DICOM metadata. CONCLUSION: DICOM dose report files were identified and retrieved from a PACS. An automated software program was used to extract from these files information from the structured elements in the DICOM metadata relevant to exposure. Extracting information from DICOM metadata eliminated potential errors inherent in techniques based on optical character recognition, yielding 100% accuracy.


Assuntos
Mineração de Dados , Doses de Radiação , Sistemas de Informação em Radiologia , Tomografia Computadorizada por Raios X , Humanos
18.
Curr Probl Diagn Radiol ; 52(3): 180-186, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36470698

RESUMO

Detection of pulmonary nodules on chest x-rays is an important task for radiologists. Previous studies have shown improved detection rates using gray-scale inversion. The purpose of our study was to compare the efficacy of gray-scale inversion in improving the detection of pulmonary nodules on chest x-rays for radiologists and machine learning models (ML). We created a mixed dataset consisting of 60, 2-view (posteroanterior view - PA and lateral view) chest x-rays with computed tomography confirmed nodule(s) and 62 normal chest x-rays. Twenty percent of the cases were separated for a testing dataset (24 total images). Data augmentation through mirroring and transfer learning was used for the remaining cases (784 total images) for supervised training of 4 ML models (grayscale PA, grayscale lateral, gray-scale inversion PA, and gray-scale inversion lateral) on Google's cloud-based AutoML platform. Three cardiothoracic radiologists analyzed the complete 2-view dataset (n=120) and, for comparison to the ML, the single-view testing subsets (12 images each). Gray-scale inversion (area under the curve (AUC) 0.80, 95% confidence interval (CI) 0.75-0.85) did not improve diagnostic performance for radiologists compared to grayscale (AUC 0.84, 95% CI 0.79-0.88). Gray-scale inversion also did not improve diagnostic performance for the ML. The ML did demonstrate higher sensitivity and negative predictive value for grayscale PA (72.7% and 75.0%), grayscale lateral (63.6% and 66.6%), and gray-scale inversion lateral views (72.7% and 76.9%), comparing favorably to the radiologists (63.9% and 72.3%, 27.8% and 58.3%, 19.5% and 50.5% respectively). In the limited testing dataset, the ML did demonstrate higher sensitivity and negative predictive value for grayscale PA (72.7% and 75.0%), grayscale lateral (63.6% and 66.6%), and gray-scale inversion lateral views (72.7% and 76.9%), comparing favorably to the radiologists (63.9% and 72.3%, 27.8% and 58.3%, 19.5% and 50.5%, respectively). Further investigation of other post-processing algorithms to improve diagnostic performance of ML is warranted.


Assuntos
Nódulos Pulmonares Múltiplos , Radiografia Torácica , Humanos , Raios X , Radiografia Torácica/métodos , Estudos Retrospectivos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Redes Neurais de Computação , Radiologistas
19.
J Clin Transl Hepatol ; 11(3): 534-539, 2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-36969887

RESUMO

Background and Aims: Distinguishing alcoholic steatohepatitis (ASH) and nonalcoholic steatohepatitis (NASH) with biopsy alone is often difficult without a reliable clinical context. A novel finding on liver imaging, perivascular branching heterogeneity, has shown promise in distinguishing between these chronic liver diseases. Our study investigated the role of this finding on imaging to differentiate between ASH and NASH. The aim of this study was to determine the utility and reproducibility of this novel radiographic marker to help distinguish ASH from NASH. Methods: This was a retrospective cohort study conducted between 2016 and 2020 in patients with both liver biopsy-confirmed steatohepatitis/chronic hepatitis and abdominal magnetic resonance imaging within 13 months of each other. Two radiologists, blinded to patient clinical history and diagnosis, categorized the appearance of the liver as: 1- homogeneity, 2- mild heterogeneity, 3- moderate heterogeneity, 4- possible perivascular branching, 5- definite perivascular branching. Results: Of the 90 patients in the study, 60 were identified as NASH and 30 as ASH. The area under the curve (AUC) for both reader 1 and 2 when using the 5-point scale was 0.69 (CI: 0.56-0.82, p=0.006) and 0.72 (CI: 0.60-0.85, p=0.001), respectively. The positive predictive value (PPV) for identification of ASH when scoring 5 was 64.7% and 66.7% for reader 1 and 2, respectively. Interclass correlation coefficient was 0.74 in patients with ASH, indicating moderate reliability among both readers. Conclusions: Identification of this perivascular branching pattern on imaging is a promising novel diagnostic marker that can be used with other methods to help distinguish between ASH and NASH.

20.
Eur J Radiol Open ; 11: 100538, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38028186

RESUMO

Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner. Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa-statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (κ = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p ≤ 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images. Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA