Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 26(8): 2446-54, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26630997

RESUMO

OBJECTIVES: To determine the influence of lowering iodinated contrast concentration on confidence of interventional radiologists in diagnosing and treating lesions during endovascular interventions in patients with symptomatic peripheral arterial disease (PAD). METHODS: A randomized controlled non-inferiority trial was performed in 60 patients. Intervention was performed with contrast concentrations (in mg of iodine per mL, mgI/mL) of 300 (standard), 240, or 140 mgI/mL. Primary outcome was confidence (score 0-100 %) of radiologists in diagnosing and treating arterial lesions. Secondary outcomes were procedural iodine load and image quality (i.e. non-diagnostic, limited, diagnostic, exemplary). RESULTS: Median confidence scores in diagnosing lesions were 100 % (range 81-100 %) for the 300 group (n = 21), 100 % (range 82-100 %) for the 240 group (n = 19), and 100 % (range 91-100 %) for the 140 group (n = 20) (both p = 1.00 compared to the 300 group). Median scores for treating lesions in the 240 and 140 groups, 100 % (range 79-100 %, p = 0.40), and 100 % (range 63-100 %, p = 0.25), respectively, were not lower compared to the 300 group (median 100 %, range 78-100 %). Procedural iodine load was lower in the 240 (24.3 ± 7.6 g, p = 0.022) and 140 groups (17.8 ± 5.6 g, p < 0.001) compared to the 300 group (29.7 ± 6.3 g). Image quality was diagnostic for all groups. CONCLUSION: Using iodine contrast of 140 mgI/mL for diagnosis and interventions in PAD patients significantly reduces administered iodine load without compromising image quality. Future use of lower iodine dose is recommended. KEY POINTS: • Lower iodinated contrast concentration during endovascular intervention does not decrease radiologist's confidence. • Image quality of standardized angiographies remains diagnostic using 140 mgI/mL iodinated contrast concentration. • Iodine load during intervention can be decreased by >40 % when using 140 mgI/mL. • Implementing the use of a lower iodinated contrast concentration will reduce the costs of the procedure.


Assuntos
Angiografia/métodos , Meios de Contraste/administração & dosagem , Iodo/administração & dosagem , Doença Arterial Periférica/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Método Duplo-Cego , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Radiology ; 257(2): 532-40, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20807851

RESUMO

PURPOSE: To assess how computer-aided detection (CAD) affects reader performance in detecting early lung cancer on chest radiographs. MATERIALS AND METHODS: In this ethics committee-approved study, 46 individuals with 49 computed tomographically (CT)-detected and histologically proved lung cancers and 65 patients without nodules at CT were retrospectively included. All subjects participated in a lung cancer screening trial. Chest radiographs were obtained within 2 months after screening CT. Four radiology residents and two experienced radiologists were asked to identify and localize potential cancers on the chest radiographs, first without and subsequently with the use of CAD software. A figure of merit was calculated by using free-response receiver operating characteristic analysis. RESULTS: Tumor diameter ranged from 5.1 to 50.7 mm (median, 11.8 mm). Fifty-one percent (22 of 49) of lesions were subtle and detected by two or fewer readers. Stand-alone CAD sensitivity was 61%, with an average of 2.4 false-positive annotations per chest radiograph. Average sensitivity was 63% for radiologists at 0.23 false-positive annotations per chest radiograph and 49% for residents at 0.45 false-positive annotations per chest radiograph. Figure of merit did not change significantly for any of the observers after using CAD. CAD marked between five and 16 cancers that were initially missed by the readers. These correctly CAD-depicted lesions were rejected by radiologists in 92% of cases and by residents in 77% of cases. CONCLUSION: The sensitivity of CAD in identifying lung cancers depicted with CT screening was similar to that of experienced radiologists. However, CAD did not improve cancer detection because, especially for subtle lesions, observers were unable to sufficiently differentiate true-positive from false-positive annotations.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA