Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Geophys Res Lett ; 46(24): 14421-14429, 2019 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-32139949

RESUMO

Transient seismicity at active volcanoes poses a significant risk in addition to eruptive activity. This risk is powered by the common belief that volcanic seismicity cannot be forecast, even on a long term. Here we investigate the nature of volcanic seismicity to try to improve our forecasting capacity. To this aim, we consider Ischia volcano (Italy), which suffered similar earthquakes along its uplifted resurgent block. We show that this seismicity marks an acceleration of decades-long subsidence of the resurgent block, driven by degassing of magma that previously produced the uplift, a process not observed at other volcanoes. Degassing will continue for hundreds to thousands of years, causing protracted seismicity and will likely be accompanied by moderate and damaging earthquakes. The possibility to constrain the future duration of seismicity at Ischia indicates that our capacity to forecast earthquakes might be enhanced when seismic activity results from long-term magmatic processes, such as degassing.

2.
Int J Artif Organs ; 31(1): 68-75, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18286457

RESUMO

Currently marketed mechanical or biological prosthetic heart valves are regarded as valid substitutes for native heart valves suffering from degenerative pathologies. These devices require strict follow-up due to dysfunctions or post-surgical complications. Potential drawbacks of these medical devices are calcification, tearing of the cusps, thromboembolism and hemolysis. In this context, a tissue engineering approach offers a promising alternative scenario. In this paper, a trileaflet poly(epsilon-caprolactone) (PCL) heart valve scaffold prototype has been manufactured by electrospinning technique using a custom-made rotating target. Process parameters were selected in order to achieve suitable microstructure and mechanical performance. The electrospun heart valve prototype was functionally characterized by means of a pulse duplicator in order to evaluate the mechanical/hydraulic response to the imposed testing conditions. Leaflets synchronously opened in the ejection phase and the proper apposition of the leaflets prevented high leakage volumes in the diastolic phase. This preliminary study suggests a successful perspective for the proposed approach in designing a novel tissue engineered bioresorbable heart valve.


Assuntos
Materiais Biocompatíveis/química , Bioprótese , Próteses Valvulares Cardíacas , Poliésteres , Alicerces Teciduais , Humanos , Teste de Materiais , Estresse Mecânico , Engenharia Tecidual/métodos
3.
J Med Eng Technol ; 31(2): 94-100, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17365433

RESUMO

Three mechanical heart valves (two bileaflet prostheses and a tilting one) were investigated in a basic hardware setup in order to evaluate with a hydrophone their opening and closing action in time and in amplitude of each beat. The recorded signal was then segmented into the series of cycles xi(t) having a temporal duration equal to the working period imposed on the valve. Two return maps were defined, in order to evaluate the degree of dispersion of the resulting scatter plot: (i) the amplitude map xi(t) versus xi+1(t); (ii) the delay map for the closure of the valve within each beat versus the successive ones. To evaluate the results obtained, two indices were proposed based on both the degree of dispersion and the deviation of the regression line of the resulting scatter plot with respect to the bisector of the map plane. The tilting disc valve showed a lower degree of dispersion, both in the amplitude signal and in the closure time delays, with respect to the other two bileaflet heart valves. The methodology proposed here could be regarded as an alternative non-invasive tool to investigate the dynamic behaviour of prosthetic heart valves, especially in the case of their suspected failure.


Assuntos
Algoritmos , Velocidade do Fluxo Sanguíneo , Análise de Falha de Equipamento/métodos , Frequência Cardíaca , Próteses Valvulares Cardíacas , Espectrografia do Som/métodos , Interpretação Estatística de Dados
4.
Int J Artif Organs ; 29(7): 709-18, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16874678

RESUMO

A three-dimensional time dependent numerical simulation was performed in a geometric model of aortic arch complete with a realistic aortic root and major branches originating from the arch, for a peak Reynolds number set at 2200 and Womersley number set at 20.4. The computational fluid dynamic analysis was aimed to provide spatial and temporal distribution of the shear stress all along the entire model together with the velocity patterns, related both to the non planar geometry of the aortic system here considered and to the pulsatility imposed on the numerical model to simulate physiologic conditions. A non-Newtonian evolving fluid was considered to account for the actual rheological nature of blood; a comparison on the incidence of wall shear stress, implementing a Newtonian fluid, was also made as reference. The spatial shear stress pattern, within the cardiac cycle, was shown to have higher values in correspondence to the inner wall of the aortic arch and the sites where the major vessels originated from the arch itself. The velocity patterns, on transversal sections of the aorta, resulted in highly skewed morphology. The resulting complex fluid dynamics, established in the aortic arch and in its branches, can be related to the possible endothelium response to mechanical stimuli, induced by wall shear stress, in the promotion of inflammatory events.


Assuntos
Aorta Torácica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Hemorreologia , Modelos Cardiovasculares , Resistência ao Cisalhamento , Aterosclerose/fisiopatologia , Simulação por Computador , Humanos , Fluxo Pulsátil/fisiologia , Estresse Mecânico
5.
J Biomech ; 35(12): 1599-612, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12445613

RESUMO

Vascular access methods, performed by the insertion of cannulae into vessels, may disturb the physiological flow of blood, giving rise to non-physiological pressure variations and shear stresses. To date, the hydrodynamic behaviour of the cannulae has been evaluated comparing their pressure loss-flow rate relationships, as obtained from in vitro experiments using a monodimensional approach; this methodology neither furnish information about the local fluid dynamics nor the established flow field in specific clinical work conditions. Since the shear stress is a critical factor in the design of artificial circulatory devices, more knowledge should be necessary about the local values assumed by the haemodynamic parameters during cannulation. An alternative way to investigate the fluid dynamic as accurately as possible is given by numeric studies. A 3D model of cannula concentrically placed in a rigid wall vessel is presented, with the finite element methodology used to numerically simulate the steady-state flow field in two different venous cannulation case studies, with two cannulae having a central hole and two or four side holes, respectively, with the same boundary conditions. Lower velocity and shear stress peak values have been computed for the model with four side holes upstream of the central hole, in the region of the cannula where the inlet flows meet and towards cannula's outlet, due to the increased flow symmetry and inlet area with respect to the model with two side holes. Starting from the investigation of different cannula designs, numerically assessing the local fluid dynamics, indications can be drawn to support both the design phase and the device optimal clinical use, in order to limit risks of biomechanical origin. Thus the presence of four side holes implied, as a consequence of the greater inlet area and of the increased symmetry, a less disturbed blood flow, together with reduced shear stress values. Furthermore, results show that the numerical simulations furnished useful informations on the interaction between vessel and cannula, e.g. on the fluid dynamics establishing in the free luminal space left, in the vessel, by the inserted cannula.


Assuntos
Cateterismo Periférico/instrumentação , Cateterismo/instrumentação , Cateterismo/métodos , Simulação por Computador , Modelos Cardiovasculares , Veias/fisiologia , Velocidade do Fluxo Sanguíneo , Cateterismo Periférico/métodos , Desenho de Equipamento/métodos , Análise de Elementos Finitos , Hemodinâmica , Hemorreologia/métodos , Humanos , Sensibilidade e Especificidade , Estresse Mecânico , Pressão Venosa/fisiologia
6.
Int J Artif Organs ; 27(1): 45-54, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14984183

RESUMO

With the aim of enhancing the safety and reliability level of coronary stents, we analyzed data collected from accident reports drawn from the MAUDE database (Manufacturer and User Facility Device Experience Database) of the FDA from 1996 to 2000. This analysis allowed us to highlight problems related to the use of coronary stents by means of the analysis of these reports at different levels, beginning from the causes that can lead to a certain type of accident up to the possible complication related to that event. Moreover we analyzed the procedure outcomes in terms of stent position inside the patient's body and the possible therapies adopted to solve the problems. The results showed that the most probable event that can lead to an accident is the stent separation from the balloon which, alone, turns up in a number of cases equal to the sum of all the others. This result highlights the importance of the technical skill of the operators accomplished by special training and of the importance of clarity and completeness in the instructions for the use of the device. Another critical point is the reliability of the device which must guarantee an adequate safety level when it is used according to the instructions.


Assuntos
Doença das Coronárias/terapia , Stents/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Humanos , Fatores de Risco , Resultado do Tratamento
7.
Int J Artif Organs ; 26(1): 64-72, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12602471

RESUMO

Clinical techniques for the restoration of a failing heart are mainly based on the use of mechanical assist devices. In recent years, with the growing need for mechanical circulatory support, these devices have been shown to be a useful therapeutic tool, thanks to their intrinsic capability to unload the failing ventricle, allowing the heart to recover. Mechanical circulatory support systems (MCSS) require an accurate biomechanical characterization of the complex interaction that occurs between the patient and the mechanical support. A protocol for MCSS testing is proposed which takes into account several working conditions, in a modified test mock loop apparatus able to mimic various pathological conditions. Both physiological and pathological conditions can be replicated to show the actual efficacy of a MCSS device in correctly supporting a wide spectrum of ventricular conditions. The test bench is able to simulate the recovery of the pathological condition quite accurately, showing, at the same time, that this set up can be a reliable choice to characterize cardiac support devices. Thus the results of this experimentation can be useful to clinicians in forecasting the response of the heart affected by a cardiac disease and to set appropriate parameters for suitable assistance.


Assuntos
Coração Auxiliar , Modelos Cardiovasculares , Disfunção Ventricular Esquerda/fisiopatologia , Velocidade do Fluxo Sanguíneo , Desenho de Equipamento , Frequência Cardíaca/fisiologia , Humanos , Software , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/terapia
8.
Int J Artif Organs ; 27(3): 231-42, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15112889

RESUMO

The association between specific blood flow patterns and blood behaviour through medical devices suggests that a Lagrangian study may be a useful instrument for the evaluation of the thrombogenic and/or hemolytic potential of certain devices' geometries and biomaterials. In this study a description of blood particle trajectories in terms of their spiral contents is proposed; such a mathematical description for blood spiral flow, computed along several pathlines, is tested for a quantitative determination of the spiralled motion of blood flow into two three-dimensional numerical models, having different design characteristics, of venous cannula inserted in a vessel. As the influence of vortical flow conditions have been observed to have both beneficial and detrimental influence on blood behaviour in terms of blood-device interaction, of the degradation of its components, and of the efficiency of mass-exchange (in red cells oxygenation and plasma filtration, for example), the herein proposed method for the description of spiral laminar motion may be a helpful instrument to build up a tool to investigate, for example, the existence of correlations between level of spiral flow and geometry (as in the present investigated test case), rather than the effects of blood-surface contact. The results obtained in this test case investigation, confirm the effectiveness of the proposed function for a quantitative analysis of spiral flow in medical devices.


Assuntos
Fenômenos Fisiológicos Sanguíneos , Equipamentos e Provisões , Velocidade do Fluxo Sanguíneo/fisiologia , Desenho de Equipamento , Humanos , Modelos Cardiovasculares
9.
Int J Artif Organs ; 26(11): 1005-14, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14708830

RESUMO

Total cavo pulmonary connection (TCPC) is one of the surgical techniques adopted to compensate the failure of the right heart in pediatric patients. The main goal of this procedure is the realization of a configuration for the caval veins and for the pulmonary arteries that can guarantee as low as possible pressure losses and appropriate lung perfusion. Starting from this point of view, a realistic TCPC with extracardiac conduit (TECPC) is investigated by means of Computational Fluid Dynamics (CFD) to evaluate the pressure loss under different pressure conditions, simulating different vessel resistances, on the pulmonary arteries. A total flow of 3 L/min, with a distribution between the inferior vena cava (IVC) and the superior vena cava (SVC) equal to 6/4, was investigated; three different boundary conditions for the pressure were imposed, resulting in three simulations in steady-state conditions, to the right pulmonary artery (RPA) and to the left pulmonary artery (LPA), simulating a balanced (deltaP(LPA-RPA) = 0 mmHg) and two unbalanced pulmonary resistances to blood flow (a pressure difference deltaP(LPA-RPA) = +/- 2 mmHg, respectively). The geometry for the TECPC was realized according to MRI derived physiological values for the vessels and for the configuration adopted for the anastomosis (the extra-cardiac conduit was inclined 22 degrees towards the left pulmonary artery with respect to the IVC axis). The computed power losses agree with previous in vitro Particle Image Velocimetry investigations. The results show that a higher resistance on the LPA causes the greater pressure loss for the TECPC under study, while the minimum pressure loss can be achieved balancing the pulmonary resistances, subsequently obtaining a balanced flow repartition towards the lungs.


Assuntos
Derivação Cardíaca Direita , Modelos Cardiovasculares , Análise Numérica Assistida por Computador , Artéria Pulmonar/fisiologia , Resistência Vascular/fisiologia , Veia Cava Inferior/fisiologia , Veia Cava Superior/fisiologia , Criança , Biologia Computacional , Humanos , Modelos Anatômicos , Reologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA