Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 281(8): 4121-4131, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38564010

RESUMO

PURPOSE: Cochlear implantation is a prevalent remedy for severe-to-profound hearing loss. Optimising outcomes and hearing preservation, and minimising insertion trauma, require precise electrode placement. Objective monitoring during the insertion process can provide valuable insights and enhance surgical precision. This study assesses the feasibility and performance of an impedance-based method for monitoring electrode insertion, compared to the surgeon's feedback. METHODS: The study utilised the Insertion Monitoring Tool (IMT) research software, allowing for real-time measurement of impedance and evoked compound action potential (eCAP) during electrode insertion in 20 patient implantations. This enabled an impedance-based method to continuously assess the status of each electrode during the insertion process. The feasibility and performance was evaluated and compared to the surgeon's feedback approach. eCAP measurements focused merely on feasibility without searching specific responses. RESULTS: The IMT demonstrated feasibility in measuring real-time impedances and eCAP during the insertion of the electrode array. The impedance-based method exhibited potential for accurately monitoring the insertion depth with a high success rate. However, further development is needed to improve the number of usable contacts. CONCLUSIONS: Objective monitoring with the impedance-based method shows promise as a valuable tool to enhance the precision of cochlear implant electrode insertion respecting insertion distance estimation. The IMT research software proved feasible in recording real-time impedances and eCAP during electrode insertion. While this impedance-based method exhibits high success rates, further improvements are required to optimise the number of usable contacts. This study highlights the potential of objective monitoring techniques to enhance cochlear implantation outcomes.


Assuntos
Implante Coclear , Implantes Cocleares , Impedância Elétrica , Estudos de Viabilidade , Humanos , Implante Coclear/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Criança , Pré-Escolar , Adolescente , Eletrodos Implantados , Potenciais Evocados Auditivos/fisiologia , Adulto Jovem , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/instrumentação
2.
IEEE Trans Biomed Eng ; 71(2): 650-659, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37682654

RESUMO

OBJECTIVE: The current study investigates whether, during a Cochlear Implant (CI) surgery, conditioning (i.e. applying short bursts of electrical stimulation) within a saline solution can have positive effects on subsequent intra-operative measurements. We hypothesize that, based on previous research, the impedance values will be reduced, and that the reproducibility of Electrically Evoked Compound Action Potentials (ECAPs) is improved as a result of conditioning. METHODS: We conditioned half of the electrode contacts, within a saline solution, before CI insertion, using 23 MED-EL implants. Impedance was measured for both the conditioned and non-conditioned groups at five time points. Repeated ECAP recordings were measured and compared between the conditioned and non-conditioned groups. RESULTS: Impedance of the electrode contacts were reduced by 31% after conditioning in saline solution; however, there were no clinically relevant differences after the implantation of the electrode array. The hypothesis that measurement reproducibility would be increased after conditioning could not be confirmed with our data. Within the saline solution, we observed that 44% of the electrode contacts were covered with air bubbles, which most disappeared after implantation. However, these air bubbles limited the effectiveness of the conditioning within the saline solution. Lastly, the effect of conditioning on the reference electrode stimulation was approximately 16% of the total reduction in impedance. CONCLUSION: Our data does not suggest that intraoperative conditioning is clinically required for cochlear implantation with MED-EL implants. Additionally, an in-vivo ECAP recording can be considered as a method of conditioning the electrode contacts. SIGNIFICANCE: We confirm that the common clinical practice does not need to be changed.


Assuntos
Implante Coclear , Implantes Cocleares , Potenciais de Ação/fisiologia , Impedância Elétrica , Reprodutibilidade dos Testes , Solução Salina , Potenciais Evocados Auditivos/fisiologia , Potenciais Evocados , Implante Coclear/métodos , Estimulação Elétrica/métodos
3.
J Vis Exp ; (198)2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37590502

RESUMO

Impedance measurements are routinely performed during cochlear implantation (CI) after finalized electrode insertion. They may allow conclusions on the electrode's and implant's function. In the postoperative setting, the analysis of impedance changes enables the identification of scarring or inflammation processes around the electrode. Recent studies report associations between impedance telemetry and the site of stimulation. Consequently, repeated impedance measurements during cochlear implant electrode insertion may enable objective feedback on whether the electrode is positioned inside the perilymph or outside the inner ear. With the presented novel method, impedances can be measured in real-time during cochlear implantation. This protocol systematically explains how to perform repeated impedance recordings during CI surgery. These repeated measurements are challenging since they depend on multiple intraoperative methodological factors starting with the draping of the patient. Thus, for successful recordings, a standardized procedure is mandatory. In this article, we comprehensively illustrate the system setup and procedure of performing intraoperative measurements during CI surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Impedância Elétrica , Cicatriz , Telemetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA