The development of alpha-emitting radiopharmaceuticals using 211At requires quantitative determination of the time-dependent nature of the 211At biodistribution. However, imaging-based methods for acquiring this information with 211At have not found wide-spread use because of its low abundance of decay emissions suitable for external detection. In this publication we demonstrate the theranostic abilities of the 211At/209At isotope pair and present the first-ever 209At SPECT images. The VECTor microSPECT/PET/CT scanner was used to image 209At with a collimator suitable for the 511 keV annihilation photons of PET isotopes. Data from distinct photopeaks of the 209At energy spectrum (195 keV (22.6%), 239 keV (12.4 %), 545 keV (91.0 %), a combined 782/790 keV peak (147 %), and 209Po x-rays (139.0 %)) were independently evaluated for use in image reconstructions using Monte Carlo (GATE) simulations and phantom studies. 209At-imaging in vivo was demonstrated in a healthy mouse injected with 10 MBq of free [209At]astatide. Image-based measurements of 209At uptake in organs of interest-acquired in 5 min intervals-were compared to ex vivo gamma counter measurements of the same organs. Simulated and measured data indicated that-due to the large amount of scatter from high energy (>750 keV) gammas-reconstructed images using the x-ray peak outperformed those obtained from other peaks in terms of image uniformity and spatial resolution, determined to be <0.85 mm. 209At imaging using the x-ray peak revealed a biodistribution that matched the known distribution of free astatide, and in vivo image-based measurements of 209At uptake in organs of interest matched ex vivo measurements within 10%. We have acquired the first 209At SPECT images and demonstrated the ability of quantitative SPECT imaging with 209At to accurately determine astatine biodistributions with high spatial and temporal resolution.
Assuntos
Astato/metabolismo , Método de Monte Carlo , Imagens de Fantasmas , Compostos Radiofarmacêuticos/metabolismo , Nanomedicina Teranóstica/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Humanos , Processamento de Imagem Assistida por Computador , Camundongos , Camundongos Endogâmicos C57BL , Distribuição TecidualRESUMO
(33)S is a stable isotope of sulfur for which the emission of an α-particle is the dominant exit channel for neutron-induced reactions. In this work the enhancement of both the absorbed and the equivalent biologically weighted dose in a BNCT treatment with 13.5keV neutrons, due to the presence of (33)S, has been tested by means of Monte Carlo simulations. The kerma-fluence factors for the ICRU-4 tissue have been calculated using standard weighting factors. The simulations depend crucially on the scarce (33)S(n,α)(30)Si cross-section data. The presence of a high resonance at 13.5keV was established by previous authors providing discrepant resonance parameters. No experimental data below 10keV are available. All of this has motivated a proposal of experiment at the n_TOF facility at CERN. A setup was designed and tested in 2011. Some results of the successful test will be shown. The experiment is scheduled for the period November to December 2012.