Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 22(1): 57, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35172730

RESUMO

BACKGROUND: Left atrial roof-dependent tachycardias (LARTs) are common macroreentrant atrial tachycardias (ATs). We sought to characterize clinical LARTs using an ultra-high resolution mapping system. METHODS: This study included 22 consecutive LARTs in 21 patients who underwent AT mapping/ablation using Rhythmia systems. RESULTS: Three, 13, 4, and 2 LART patients were cardiac intervention naïve (Group-A), post-roof line ablation (Group-B), post-atrial fibrillation ablation without linear ablation (Group-C), and post-cardiac surgery (Group-D), respectively. The mean AT cycle length was 244 ± 43 ms. Coronary sinus activation was proximal-to-distal or distal-to-proximal in 16 (72.7%) ATs. The activation map revealed 13 (59.1%) clockwise and 9 (40.9%) counter-clockwise LARTs. A 12-lead synchronous isoelectric interval was observed in 10/19 (52.6%) LARTs. The slow conduction area was identified on the LA roof, anterior/septal wall, and posterior wall in 18, 6, and 2 ATs, respectively. Twenty concomitant ATs among 13 procedures were also eliminated, and peri-mitral AT coexisted in 7 of 9 non-group-B patients. In group-B, the conduction gap was predominantly located on the mid-roof. Sustained LARTs were terminated by a single application and linear ablation in 6 (27.3%) and 9 (40.9%), while converting to other ATs in 7 (31.8%) LARTs. Complete linear block was created without any complications in all, however, ablation at the mid-posterior wall was required to achieve block in 4 (18.2%) procedures. During 14.0 (6.5-28.5) months of follow-up, 17 (81.0%) and 19 (90.5%) patients were free from any atrial tachyarrhythmias after single and last procedures. CONCLUSIONS: The LART mechanisms were distinct in individual patients, and elimination of all concomitant ATs was required for the management.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/cirurgia , Taquicardia Supraventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
2.
Heart Vessels ; 37(12): 2049-2058, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35790552

RESUMO

BACKGROUND: Few studies have examined whether catheter ablation for AF patients improves biomarkers other than serum levels of brain natriuretic peptide (BNP) and renal function. This study was to explore whether catheter ablation for atrial fibrillation (AF) patients affects uric acid (UA), glucose and lipid metabolism. METHODS AND RESULTS: A total of 206 patients (66.6 ± 10.4 years; 132 men) who underwent initial AF ablation without changes to oral medications were included. Baseline BNP and UA levels significantly decreased at 1 year after ablation (p < 0.05 each). Changes in UA level correlated significantly with pre-procedural UA level (r = 0.57). In multivariable logistic regression modeling, pre-procedural UA level, persistent AF, and hemoglobin A1c (p < 0.05 each) were independent predictors of post-procedural UA level decline. Significant improvements in both persistent and paroxysmal AF patients were identified, and the magnitude of post-procedural serum UA level decline after ablation (ΔUA) was significantly greater in patients with persistent AF (0.8 ± 1.0 mg/dl) than in those with paroxysmal AF (0.2 ± 0.8 mg/dl, p < 0.001). Of the 48 patients with high UA level before procedure, 28 patients showed improvement in UA level to normal range. CONCLUSIONS: Catheter ablation for AF patients significantly improved serum UA levels without obvious influences of heart failure, renal function, or inflammation, suggesting that AF ablation may be effective for AF patients with hyperuricemia. Trial registration The study was approved by the Research Ethics Committee of University of Fukui (no. 20210132) and clinical trial registration (UMIN000044669).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ácido Úrico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Biomarcadores/sangue , Glucose/metabolismo , Lipídeos/sangue , Resultado do Tratamento , Ácido Úrico/sangue
3.
Int Heart J ; 63(1): 49-55, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35095076

RESUMO

The diagnosis of cardiac amyloidosis is frequently delayed because histological confirmation is often challenging. Few studies have attempted to clarify the utility and safety of abdominal fat pad fine-needle aspiration (FPFNA) for an initial screening test in patients with suspected cardiac amyloidosis.This study included 77 consecutive patients with suspected non-ischemic cardiomyopathy who had left ventricular dysfunction and/or hypertrophy. All patients underwent abdominal FPFNA and an endomyocardial biopsy. In all patients, the abdominal FPFNA could be performed within less than 5 minutes with no complications; however, in 1 patient (1.3%), the obtained specimen was too small to evaluate. Among the remaining 76 patients, 5 (6.6%) were positive for amyloid (FPFNA[+]) and 7 (9.2%), including the 5 FPFNA[+], were diagnosed with cardiac amyloidosis (AL = 1, ATTR = 6) by endomyocardial biopsy. Positive abdominal FPFNAs indicated cardiac amyloidosis with high accuracy (sensitivity, 71.4%; specificity, 100%).Positive abdominal FPFNAs are directly linked to diagnoses of cardiac amyloidosis. Abdominal FPFNA is simple and useful for the initial screening test for cardiac amyloidosis in patients with non-ischemic cardiomyopathy.


Assuntos
Gordura Abdominal/patologia , Amiloidose/diagnóstico , Biópsia por Agulha Fina , Cardiopatias/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Endocárdio/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico
4.
J Cardiovasc Electrophysiol ; 32(5): 1305-1319, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33682247

RESUMO

BACKGROUND: Low voltage areas (LVAs) are most commonly observed on the left atrial (LA) septal/anterior wall. OBJECTIVE: We explored the mechanisms of LA septal/anterior wall reentrant tachycardias (LASARTs) using ultrahigh resolution mapping. METHODS: This study included seven consecutive LASARTs in six patients (75 [62.2-82.8] years, 4 women) who underwent atrial tachycardia (AT) mapping and ablation using Rhythmia systems. RESULTS: The AT cycle length was 266 (239-321) ms. During ATs, 11.0 (9.0-12.9) cm2 of LVAs were identified in all, and 0.8 (0.7-1.7) cm2 of dense scar was identified in four patients. Five ATs rotated around dense scar, while two rotated around functional linear block, which was confirmed during atrial pacing after AT termination. The AT circuit length was 8.7 ± 2.1 cm with a conduction velocity of 30.4 ± 3.7 cm/s. A median of 3.0 (2.0-4.0) slow conduction areas per circuit were identified, and 17/23 (73.9%) areas were present in LVAs, while they were at the border of the LVA and normal voltage areas in the remaining 6/23 (26.1%). Global activation histograms facilitated the identification of the critical isthmus in all. Tailor-made ablation at critical isthmuses successfully eliminated all ATs. However, one patient with AT related to functional linear block experienced recurrent AT related to dense scar, which progressed after the procedure. During a mean 14 ± 13 month follow-up after the last procedure, no patients experienced recurrent ATs without any complications. CONCLUSION: LASARTs consist of not only fixed conduction blocks but also functional conduction blocks. Ultrahigh resolution mapping is highly useful to decide the optimal tailor-made ablation strategy based on the mechanisms.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Feminino , Átrios do Coração/cirurgia , Frequência Cardíaca , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
5.
Heart Vessels ; 36(7): 1027-1034, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33507357

RESUMO

Reported mapping procedures of left atrial (LA) low-voltage areas (LVAs) vary widely. This study aimed to compare the PentaRay®/CARTO®3 (PentaRay map) and Orion™/Rhythmia™ (Orion map) systems for LA voltage mapping. This study included 15 patients who underwent successful pulmonary vein isolation (PVI) for atrial fibrillation. After PVI, PentaRay and Orion maps created for all patients were compared. LVAs were defined as sites with ≥ 3 adjacent low-voltage points < 0.5 mV. LVAs were indicated in 8 (53%) among 15 patients, and the average values of the measured LVAs was comparable between the systems (PentaRay map = 5.4 ± 8.7 cm2; Orion map = 4.3 ± 6.4 cm2, p = 0.69). However, in 2 of 8 patients with LVAs, the Orion map indicated LVAs at the septum and posterolateral sites of the LA, respectively, whereas the PentaRay map indicated no LVAs. In those patients, sharp electrograms of > 0.5 mV were properly recorded at the septum and posterolateral sites during appropriate beats in the PentaRay map. The PentaRay map had a shorter procedure time than the Orion map (12 ± 3 min vs. 23 ± 8 min, respectively; p < 0.01). Our study results showed a discrepancy in the LVA evaluation between the PentaRay and Orion maps. In 2 of 15 patients, the Orion map indicated LVAs at the sites where > 0.5-mV electrograms were properly recorded in the PentaRay map.


Assuntos
Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo/fisiologia , Mapeamento Potencial de Superfície Corporal/métodos , Átrios do Coração/fisiopatologia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia
6.
J Cardiovasc Electrophysiol ; 31(6): 1385-1393, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32249492

RESUMO

BACKGROUND: Few studies have examined the characteristics of catheter ablation vascular complications, and recently physicians increasingly use computed tomography angiography (CTA) for diagnosing. OBJECTIVE: We sought to investigate the incidence of femoral vascular complications in catheter ablation and factors associated with complications in the current era. METHODS: This single-center observational study consisted of 311 consecutive (atrial fibrillation, atrial flutter, paroxysmal supraventricular tachycardia, and ventricular arrhythmias in 222 [71.4%], 7 [2.3%], 43 [13.8%], and 39 [12.5%]) patients who underwent catheter ablation. The detailed patient data and clinical outcomes were obtained from the medical records. RESULTS: Emergent CTA was performed in a total of 8 (2.6%) patients at a median of 4.5 (2.0-12.5) days postprocedure, and the precise diagnosis was obtained in all. Among them, pseudoaneurysms, arteriovenous fistulae (AVF), and actively bleeding hematomas were identified in two, one, and one patient, respectively, and all required readmissions after discharge. AVF was diagnosed by a Doppler ultrasound examination in another patient. In total, 5 (1.6%) patients exhibited major femoral vascular complications including two pseudoaneurysms, two AVFs, and one active bleeding hematoma. The pseudoaneurysms and AVFs were successfully eliminated by direct compression, and extravasation from the femoral circumflex artery required coil embolization. Antiplatelet therapy and the use of larger arterial sheaths (≥7-Fr) increased the major femoral arterial complications, but atrial fibrillation ablation under uninterrupted anticoagulation therapy or the use of larger venous sheaths did not. CONCLUSION: Vascular complications are still not negligible procedure-related complications during catheter ablation in the current era. CTA provides a rapid and precise diagnosis for optimal treatment strategies.


Assuntos
Ablação por Cateter/efeitos adversos , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada , Artéria Femoral/diagnóstico por imagem , Lesões do Sistema Vascular/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral/lesões , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/epidemiologia , Lesões do Sistema Vascular/terapia
7.
J Cardiovasc Electrophysiol ; 31(5): 1075-1082, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32108407

RESUMO

BACKGROUND: Atrial linear lesions are generally created with radiofrequency energy. We sought to evaluate the feasibility of cryothermal atrial linear ablation. METHODS AND RESULTS: Twenty-one atrial fibrillation (AF) patients underwent linear ablation on the left atrial (LA) roof, mitral isthmus (MI), and cavotricuspid isthmus (CTI) with 8-mm-tip cryocatheters following pulmonary vein isolation. The data were compared with those of 31 patients undergoing linear ablation with irrigated-tip radiofrequency catheters. Conduction block was successfully created in 18 of 20 (90%), 9 of 21 (43%), and 20 of 20 (100%) on the LA roof, MI, and CTI by endocardial cryoablation alone with 19.0 (12.0-24.0), 30.0 (23.0-34.0), and 14.0 (14.0-16.0) minute cryo applications, respectively. The presence of either an interposed circumflex artery or pouch at the MI was significantly associated with failed MI block (P = .04). Conduction block was created in 25 of 31 (83.9%), 27 of 31 (87.1%), and 30 of 31 (96.8%) on the roof, MI, and CTI, respectively, by radiofrequency ablation. During the 17.5 (13.0-31.7) months of follow-up, freedom from AF/atrial tachycardia (AT) was significantly higher in the cryo group (P = .05); especially, recurrent AT was more frequent in the RF group (8/31 vs 1/21; P = .03). Conduction block across the roof, MI, and CTI was durable in 6 of 12 (50.0%), 4 of 12 (33.3%), and 9 of 12 (75.0%) patients during second procedures. All nine patients (except one) with recurrent ATs had at least one roof or MI conduction resumption. CONCLUSIONS: Cryoablation is effective for creating a roof and CTI linear block, however, creating MI block by endocardial ablation alone was often challenging. Conduction resumption of LA linear block is common and recurrent arrhythmias, especially iatrogenic ATs, are more frequently observed after radiofrequency linear ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo
8.
Heart Vessels ; 35(2): 246-251, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31440830

RESUMO

Atrial tachyarrhythmias often originate from the superior vena cava (SVC), and right superior (RSPV) and inferior pulmonary veins (RIPV). However, a precise differentiation of those origins is challenging using the standard 12-lead electrocardiogram (ECG) P-wave morphology due to the anatomical proximity. The recently developed synthesized 18-lead ECG provides virtual waveforms of the right-sided chest and back leads. This study evaluated the utility of the synthesized 18-lead ECG to differentiate atrial arrhythmias originating from 3 adjacent structures. Synthesized 18-lead ECGs were obtained during SVC-, RSPV-, and RIPV-pacing in 20 patients with lone paroxysmal atrial fibrillation to develop an algorithm. The P-wave morphologies were classified into 4 patterns: positive, negative, biphasic, and isoelectric. Subsequently, the algorithm's accuracy was validated prospectively in another 40 patients. In retrospective analyses, isoelectric P-waves in synthesized V7 distinguished RIPV-pacing from the others (sensitivity = 81%, specificity = 92%) (first criteria). The P wave morphologies in Leads II (sensitivity = 83%, specificity = 94%) and V1 (sensitivity = 84%, specificity = 80%) distinguished SVC- and RSPV-pacing (second criteria). In a prospective evaluation, the sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV], and accuracy of the first criteria for identifying RIPV-pacing was 97%, 90%, 78%, 99%, and 92%, respectively. The sensitivity, specificity, RPV, NPV, and accuracy of the second criteria (amplitudes > 1 mV in lead II or biphasic P-waves in lead V1) for discriminating SVC- and RSPV-pacing was 66%, 95%, 98%, 50%, and 74%, respectively. The P wave morphology pattern in lead V7 in synthesized 18-lead ECGs is useful for differentiating RIPV origins from RSPV/SVC origins.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Veia Cava Superior/fisiopatologia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Diagnóstico Diferencial , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo
9.
J Cardiovasc Electrophysiol ; 30(10): 1841-1847, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31328311

RESUMO

BACKGROUND: The utility of pressure waveform analyses to assess pulmonary vein (PV) occlusions has been reported in cryoballoon PV isolation (CB-PVI) using first-generation CBs. This prospective randomized study compared the procedural and clinical outcomes of pressure-guided and conventional CB-PVI. METHODS AND RESULTS: Sixty patients with paroxysmal atrial fibrillation underwent CB-PVI with 28-mm second-generation CBs. PV occlusions were assessed either by real-time pressure waveforms without contrast utilization (pressure-guided group) or contrast injections (conventional group) and randomly assigned. Before the randomization, 24 patients underwent pressure-guided CB-PVIs. In the derivation study, a vein occlusion was obtained in 88/96 (91.7%) PVs among which 86 (97.7%) were successfully isolated by the application. In the validation study, the nadir balloon temperature and total freezing time did not significantly differ per PV between the two groups. The positive predictive value of the vein occlusion for predicting successful acute isolations was similar (93 of 103 [90.2%] and 89 of 98 [90.8%] PVs; P = 1.000), but the negative predictive value was significantly higher in pressure-guided than angiographical occlusions (14 of 17 [82.3%] vs 7 of 22 [31.8%]; P = .003). Both the procedure (57.7 ± 14.2 vs 62.6 ± 15.8 minutes; P = .526) and fluoroscopic times (16.3 ± 6.4 vs 20.1 ± 6.1; P = .732) were similar between the two groups, however, the fluoroscopy dose (130.6 ± 97.7 vs 353.2 ± 231.4 mGy; P < .001) and contrast volume used (0 vs 17.5 ± 7.7 mL; P < .001) were significantly smaller in the pressure-guided than conventional group. During 27.8 (5-39) months of follow-up, the single procedure arrhythmia freedom was similar between the two groups (P = .438). CONCLUSIONS: Pressure-guided second-generation CB-PVIs were similarly effective and as safe as conventional CB-PVIs. This technique required no contrast utilization and significantly reduced radiation exposure more than conventional CB-PVIs.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Criocirurgia , Veias Pulmonares/cirurgia , Pressão Venosa , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Meios de Contraste/administração & dosagem , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Feminino , Frequência Cardíaca , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Flebografia , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Radiografia Intervencionista , Reprodutibilidade dos Testes , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento
10.
Heart Vessels ; 34(3): 509-516, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30182157

RESUMO

Experimental data suggest that cryoenergy is associated with less endothelial damage and thrombus formation than radiofrequency energy. This study aimed to compare the impact of pulmonary vein isolation (PVI) on the endothelial damage, myocardial damage, inflammatory response, and prothrombotic state between the two latest technologies, second-generation cryoballoon (CB2) and contact force-sensing radiofrequency catheter (CFRF) ablation. Eighty-six paroxysmal atrial fibrillation (AF) patients (55 men; 65 ± 12 years) underwent PVI with either the CB2 (n = 64) or CFRF (n = 22). Markers of the endothelial damage (L-arginine/asymmetric dimethylarginine [ADMA]), myocardial injury (creatine kinase-MB [CK-MB], troponin-T, and troponin-I), inflammatory response (high-sensitive C-reactive protein), and prothrombotic state (D-dimer, soluble fibrin monomer complex, and thrombin-antithrombin complex) were determined before and up to 24-h post-procedure. The total application time was shorter (1,460 ± 287 vs. 2,395 ± 571 [sec], p < 0.01) and total procedure time tended to be shorter (199 ± 37 vs. 218 ± 38 [min], p = 0.06) with CB2 than CFRF ablation. The amount of myocardial injury was greater (CK-MB: 45 ± 17 vs. 11 ± 3 [IU/l], p < 0.01) with CB2 than CFRF ablation. The L-arginine/ADMA ratio was lower (160 ± 51 vs. 194 ± 38, p = 0.028) after CB2 than CFRF ablation. Inflammatory and all prothrombotic markers were significantly elevated post-ablation; however, the magnitude was similar between the two groups. During a mean follow-up of 20 ± 6 months, the single-procedure AF freedom was similar between the CB2 and CFRF groups (60/64 vs. 20/22, p = 0.82). CB2-PVI produces significantly lesser endothelial damage with greater myocardial injury than CFRF-PVI; however, similar anticoagulant regimens are required during the peri-procedural periods in both technologies.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Endotélio Vascular/fisiopatologia , Veias Pulmonares/cirurgia , Tromboembolia/etiologia , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Tromboembolia/fisiopatologia , Tromboembolia/prevenção & controle , Fatores de Tempo , Vasodilatação
11.
Heart Vessels ; 34(10): 1703-1709, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30953137

RESUMO

Cavo-tricuspid isthmus (CTI) anatomies are highly variable, and specific anatomies lead to a difficult CTI ablation. This study aimed to compare the clinical utility of angiography and intracardiac echocardiography (ICE) in evaluating CTI anatomies, and to investigate the impact of the CTI anatomy on the procedure when the ablation tactic was adjusted to the anatomy. This study included 92 consecutive patients who underwent a CTI ablation. The CTI morphology was assessed with both right atrial angiography and ICE before the ablation, and the ablation tactic was adjusted to the anatomy. The mean CTI length was 34 ± 9 mm. On ICE imaging, 21 (23%) patients had a flat CTI, while 41 (45%) had a concave CTI with a mean depth of 5.6 ± 2.7 mm. The remaining 30 (32%) had a distinct pouch with a mean depth of 6.4 ± 2.3 mm, located at the posterior, middle, and anterior isthmus in 15, 14, and 1 patients, respectively. The Eustachian ridge (ER) was visualized in 46 (50%) patients. On angiography, a pouch and ER were detected in 22 and 15 patients, but not in the remaining 8 and 31, respectively. A complete CTI block line was created in all patients without any complications. The CTI anatomy did not significantly impact any procedural parameters. ICE was superior to angiography in evaluating the detailed CTI anatomy, especially pouches and the ER. An adjustment of the ablation tactic to the anatomy could overcome the procedural difficulties of the CTI ablation in cases with specific anatomies.


Assuntos
Angiografia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Ecocardiografia , Sistema de Condução Cardíaco/anatomia & histologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Idoso , Artérias/anatomia & histologia , Artérias/diagnóstico por imagem , Artérias/patologia , Feminino , Átrios do Coração/anatomia & histologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Sistema de Condução Cardíaco/patologia , Septos Cardíacos/anatomia & histologia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/patologia , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Cuidados Intraoperatórios , Japão , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Resultado do Tratamento , Valva Tricúspide/anatomia & histologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia
12.
Int Heart J ; 60(6): 1315-1320, 2019 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-31735780

RESUMO

Uninterrupted anticoagulation therapy during atrial fibrillation (AF) ablation minimizes the risk of periprocedural thromboembolic events. Although the use of direct oral anticoagulants (DOACs) has rapidly developed in patients undergoing AF ablation, no antidote is available for factor Xa inhibitors. We sought to investigate the feasibility of an uninterrupted DOAC protocol with temporary switching to dabigatran ("dabigatran bridge") for AF ablation.The study consisted of consecutive 137 patients in whom DOACs were interrupted on the procedural day with heparin bridging (interrupted group) and 135 in whom DOACs were uninterrupted with temporary switching to dabigatran during the periprocedural hospitalization period ("dabigatran bridge" group). The coagulation markers were measured just before and after the ablation procedure. The adverse events during and up to 8 weeks after the procedure were compared according to the definition of the International Society on Thrombosis and Hemostasis.The patients were significantly older in the "dabigatran bridge" group; however, the other baseline patient characteristics were similar between the two groups. The incidence of all adverse events was comparable between the two groups (8/137 versus 8/135, P = 0.96); however, one patient from the interrupted group experienced stroke, and another from the "dabigatran bridge" group experienced cardiac tamponade, which was safely managed with an antidote. In the "dabigatran bridge" group, the activated partial thromboplastin time was significantly longer, and coagulation markers (soluble fibrin monomer and thrombin-antithrombin complexes) were significantly lower than in the interrupted group before ablation.The "dabigatran bridge" seems to be a reasonable anticoagulation protocol to minimize the thromboembolic risk while ensuring safety in patients undergoing AF ablation and taking factor Xa inhibitors.


Assuntos
Antitrombinas/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Dabigatrana/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia/prevenção & controle , Administração Oral , Idoso , Protocolos Clínicos , Esquema de Medicação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Tromboplastina Parcial
13.
Heart Vessels ; 33(11): 1301-1310, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29789902

RESUMO

The aim of this study was to evaluate the relationships among the traditional risk factors, lipid profile, and pentraxin-3 in stable angina (SAP). Plasma pentraxin-3 and serum LDL, HDL, and high-sensitivity CRP levels were measured in 163 SAP and 28 non-coronary artery disease (CAD) patients. Their relationships with five risk factors, hypertension (HT), dyslipidemia (DL), diabetes mellitus (DM), obesity (body mass index: BMI > 25 kg/m2), and high age (> 75 years), were evaluated. No significant difference was observed in the pentraxin-3 level between patients in SAP and in non-CAD [2.1 (1.4-3.5) ng/ml versus off 2.6 (1.6-3.8) ng/ml, P = 0.56). In SAP patients, pentraxin-3 levels decreased with more risk factors, according to the number of 3 traditional risk factors (HT, DL, and DM) and the number of 5 expanded risk factors (HT, DL, DM, obesity, and high age) (P for trend = 0.01 and 0.05, respectively). Pentraxin-3 showed a positive association with HDL (rs = 0.229; P = 0.050) and an inverse association with LDL (rs = - 0.224; P = 0.045). On multiple logistic regression, the number of 3 traditional risk factors was a significant predictor of pentraxin-3 levels (odds ratio = 0.444; 95% confidence interval 0.205-0.963, P = 0.040) in SAP patients. In SAP patients, the cardiovascular risk factor burden remained a negative impact on pentraxin-3 levels after multivariate analysis, suggesting that they have distinct roles in atherosclerosis.Trial registration: UMIN000023837.


Assuntos
Angina Estável/sangue , Proteína C-Reativa/metabolismo , Doença da Artéria Coronariana/sangue , Lipídeos/sangue , Medição de Risco , Componente Amiloide P Sérico/metabolismo , Proteínas de Fase Aguda , Idoso , Idoso de 80 Anos ou mais , Angina Estável/epidemiologia , Biomarcadores/sangue , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Estudos Transversais , Feminino , Humanos , Incidência , Japão/epidemiologia , Masculino , Fatores de Risco
14.
J Nucl Cardiol ; 24(5): 1641-1650, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27301963

RESUMO

BACKGROUND: In successfully revascularized acute myocardial infarction (AMI), microvascular function in a myocardial flow-glucose metabolism mismatch pattern has not been reported. We aimed to elucidate myocardial flow reserve (MFR) and myocardial viability in mismatch segments. METHODS: 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and adenosine stress 13N-ammonia PET were performed in eighteen AMI patients to evaluate myocardial glucose metabolism, myocardial blood flow (MBF), and MFR. Infarct segments were classified into 3 groups: normal (preserved resting MBF), mismatch (preserved FDG uptake but reduced resting MBF), and match (reduced FDG uptake and resting MBF). Regional wall motion score (WMS) was assessed immediately after reperfusion and recovery periods. RESULTS: MFR in the mismatch group was significantly lower than that in non-infarct-related segments (1.655 ± 0.516 vs 2.282 ± 0.629, P < .01) and similar to that in the match group (1.635 ± 0.528, P = .999). WMS in the mismatch group was significantly improved (3.07 ± 0.48 vs 2.07 ± 1.14, P = .003); however, in recovery periods, WMS in the mismatch group was significantly higher than that in the normal group (1.05 ± 1.04, P < .01). CONCLUSIONS: In successfully revascularized AMI, microvascular function is impaired despite preserved myocardial glucose metabolism in mismatch segments.


Assuntos
Glicemia/metabolismo , Microcirculação , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Circulação Coronária , Feminino , Fluordesoxiglucose F18 , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reperfusão Miocárdica , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons
15.
Eur J Nucl Med Mol Imaging ; 40(8): 1155-62, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23624765

RESUMO

PURPOSE: Positron emission tomography (PET) with (18)F-fluorodeoxyglucose (FDG) has been reported to be unreliable for identifying viable myocardium in acute myocardial infarction (AMI), especially in areas with discordance in myocardial blood flow (MBF) and glucose metabolism. In myocardium with decreased FDG uptake but preserved MBF, referred to as exhibiting reverse mismatch, myocardial viability remains controversial and little is known about the metabolic state. The aims of this study were to clarify substrate use and to estimate myocardial viability in infarct areas exhibiting reverse mismatch. METHODS: Eighteen AMI patients with successful revascularisation were included in this study. Two weeks after onset, (11)C-acetate and (18)F-FDG PET were performed to evaluate regional oxygen consumption (k mono), MBF and glucose metabolism. Free fatty acid (FFA) metabolism was evaluated with (123)I-15-(p-iodophenyl)-3-(R, S)-methylpentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT). To assess wall motion, movement in left ventricular endocardial surface was calculated using ECG-gated (99m)Tc-tetrofosmin SPECT. RESULTS: The %k mono values in reverse mismatch segments (52.6 ± 13.6%) were not significantly different from those in non-infarct segments (60.4 ± 12.8%, p = 0.071) and normal match segments (preserved MBF and FDG uptake) (58.6 ± 11.6%, p = 0.396), although regional wall motion was more severely impaired (3.06 ± 2.52 mm vs 6.78 ± 3.17 mm, p < 0.0001, and vs 5.30 ± 2.33 mm, p = 0.042, respectively). Compared to segments with reduced match (reduced MBF and FDG uptake), %k mono and %BMIPP uptake were significantly higher in reverse mismatch segments (52.6 ± 13.6% vs 37.4 ± 8.9%, p = 0.0002, and 58.8 ± 10.6% vs 40.2 ± 10.7%, p < 0.0001). CONCLUSION: Reverse mismatch in reperfused AMI patients, high oxygen consumption and FFA metabolism were observed despite decreased glucose metabolism. We conclude that reverse mismatch indicated the myocardium with early restoration of MBF and aerobic FFA metabolism.


Assuntos
Circulação Coronária , Glucose/metabolismo , Infarto do Miocárdio/diagnóstico por imagem , Revascularização Miocárdica , Oxigênio/metabolismo , Idoso , Idoso de 80 Anos ou mais , Ácidos Graxos não Esterificados/metabolismo , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Consumo de Oxigênio , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único
16.
J Arrhythm ; 39(2): 227-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37021023

RESUMO

Don't blindly accept the automated assessment of electrocardiogram. It is important to raise long QT syndrome to the differential diagnosis of repeated syncope.

17.
J Atheroscler Thromb ; 28(7): 754-765, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32981918

RESUMO

AIM: The aim of this study was to examine the effects of evolocumab on favorable limb events in patients with chronic limb-threatening ischemia (CLTI). METHODS: A single-center, prospective observational study was performed on 30 patients with CLTI. The subjects were divided into 2 groups based on evolocumab administration: evolocumab-treated (E) group ( n=14) and evolocumab non-treated (non-E) group (n=16). The primary outcome was 12-month freedom from major amputation. The secondary outcomes were 12-month amputation-free survival (AFS), overall survival (OS), and wound-free limb salvage. The mean follow-up period was 18±11 months. RESULTS: No significant difference was detected between the two groups for the 12-month freedom from major amputation (log-rank p=0.15), while the 12-month AFS rate was significantly higher in the E group than that in the non-E group (log-rank p=0.02). The 12-month OS rate in the E group was shown a tendency for improvement, as compared with that in the non-E group (log-rank p=0.056). Evolocumab administration was not associated with a significant change in freedom from major amputation (HR, 0.23, 95% CI, 0.03-2.07, p=0.19). However, evolocumab administration was related to a tendency for improvement of AFS and OS (HR, 0.13, 95% CI, 0.02-1.06, p=0.056; HR, 0.16, 95% CI, 0.02-1.37, p=0.09, respectively). Moreover, The E group had a higher proportion of wound-free limb salvage at 12 months (92% vs. 42%, p=0.03). CONCLUSION: Evolocumab administration was associated with a better AFS outcome in patients with CLTI. Long-term administration of evolocumab over 12 months contributed to improving proportion of wound-free limb salvage.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Isquemia Crônica Crítica de Membro , Tratamento Conservador/métodos , Idoso , Isquemia Crônica Crítica de Membro/diagnóstico , Isquemia Crônica Crítica de Membro/tratamento farmacológico , Isquemia Crônica Crítica de Membro/epidemiologia , Feminino , Humanos , Japão/epidemiologia , Salvamento de Membro/métodos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Inibidores de PCSK9/administração & dosagem , Doença Arterial Periférica/complicações , Doença Arterial Periférica/epidemiologia , Doença Arterial Periférica/terapia , Estudos Prospectivos , Risco Ajustado/métodos , Análise de Sobrevida
18.
Coron Artery Dis ; 32(4): 309-316, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33196580

RESUMO

BACKGROUND: An association between early repolarization and ventricular fibrillation has recently been reported in patients with vasospastic angina (VSA). However, no studies have clarified whether the presence of early repolarization can predict VSA. METHODS: Participants comprised 286 patients (136 males) with clinically suspected VSA who underwent intracoronary provocation tests using acetylcholine or ergonovine. Patients were divided into a VSA group [n = 94, positive provocation test as induction of coronary arterial spasm (>90% stenosis)] and a non-VSA group (n = 192). Detailed early repolarization data were compared between groups. RESULTS: The VSA group showed a higher frequency of smokers (28.7%) than the non-VSA group (17.2%; P = 0.02). On baseline 12-lead ECG, early repolarization (defined as a J-point elevation ≥0.1 mV from baseline in both or either of inferolateral leads) was found in 39 patients (inferior leads, n = 27; inferolateral leads, n = 12). Early repolarization was found more frequently in the VSA group (28.7%) than in the non-VSA group (6.2%, P < 0.01). Multivariate analysis revealed early repolarization as an independent predictor of VSA (odds ratio, 5.22; 95% confidence interval, 2.41-11.2; P < 0.01). Early repolarization pattern features including inferior lead, higher amplitude, notched type and horizontal/descending ST segments were associated with increased risk of VSA. CONCLUSION: In patients with resting chest pain, early repolarization was a predictor of VSA that could be particularly related to the inferior lead, higher amplitude, notched type and horizontal/descending ST segment.


Assuntos
Angina Pectoris Variante/fisiopatologia , Vasoespasmo Coronário/fisiopatologia , Eletrocardiografia , Acetilcolina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fibrilação Ventricular/fisiopatologia
19.
Intern Med ; 60(22): 3543-3549, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34092728

RESUMO

Objectve To assess the impact of glycemic variability on blood pressure in hospitalized patients with cardiac disease. Methods In 40 patients with cardiovascular disease, the glucose levels were monitored by flash continuous glucose monitoring (FGM; Free-Style Libre™ or Free-Style Libre Pro; Abbott, Witney, UK) and self-monitoring blood glucose (SMBG) for 14 days. Blood pressure measurements were performed twice daily (morning and evening) at the same time as the glucose level measurement using SMBG. Results The detection rate of hypoglycemia using the FGM method was significantly higher than that with the 5-point SMBG method (77.5% vs. 5.0%, p<0.001). Changes in the systolic blood pressure from evening to the next morning [morning - evening (ME) difference] were significantly correlated with night glucose variability (r=0.63, P<0.001). A multiple regression analysis showed that night glucose variability using FGM was more closely correlated with the ME difference [r=0.62 (95% confidence interval, 0.019-0.051); p<0.001] than with the age, body mass index, or smoking history. Night glucose variability was also more closely associated with the ME difference in patients with unstable angina pectoris (UAP) than in those with acute myocardial infarction (AMI) or heart failure (HF) (r=0.83, p=0.058). Conclusion Night glucose variability is associated with the ME blood pressure difference, and FGM is more accurate than the 5-point SMBG approach for detecting such variability.


Assuntos
Automonitorização da Glicemia , Cardiopatias , Glicemia , Pressão Sanguínea , Glucose , Humanos
20.
Heart Rhythm ; 18(2): 189-198, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33007441

RESUMO

BACKGROUND: Perimitral atrial tachycardias (PMATs) are common atrial tachycardias (ATs), yet their mechanisms vary. OBJECTIVE: The purpose of this study was to characterize clinical spontaneous PMATs using an ultra-high-resolution (UHR) mapping system. METHODS: The study included 32 consecutive PMATs in 31 patients who had undergone AT mapping/ablation using a UHR mapping system. RESULTS: Six, 10, 11, and 5 PMATs occurred in cardiac intervention-naïve (group A), post-lateral/posterior mitral isthmus linear ablation (group B), post-atrial fibrillation ablation without mitral isthmus linear ablation (group C), and post-cardiac surgery (group D) patients, respectively. Group A patients tended to be older, more likely were female, and had sinus node or atrioventricular conduction disturbances more frequently. A 12-lead synchronous isoelectric interval was observed in 15 PMATs (46.9%). Coronary sinus activation was proximal to distal or distal to proximal except in 3 PMATs with straight patterns due to epicardial gaps. Left atrial anterior/septal wall (LAASW) low-voltage areas were smallest in group B. Slow conduction areas (SCAs) were identified in 26 PMATs (81.2%) and were located on the LAASW in all group A and group D patients. Conduction velocity in the SCAs was slowest in group B. In group B, all PMATs were terminated by single applications, and the gaps were located epicardially in 5 of 10 (50%). Anterior (n = 23) or lateral/posterior (n = 9) mitral isthmus linear block was successfully created without any complications in all. Twenty-five concomitant ATs among 18 patients (58.1%) also were eliminated. During a median of 20.0 (11.0-40.0) months of follow-up, 28 patients (90.3%) were free from any atrial tachyarrhythmias. CONCLUSION: An UHR mapping-guided approach with identification of the individual tachycardia mechanism should be the preferred strategy given the distinct and complex arrhythmia mechanisms.


Assuntos
Função Atrial/fisiologia , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Imageamento Tridimensional/métodos , Taquicardia Supraventricular/cirurgia , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA