1.
Clin Oral Investig ; 26(2): 1375-1389, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34401947

RESUMO

OBJECTIVES: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. MATERIAL AND METHODS: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. RESULTS: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. CONCLUSIONS: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. CLINICAL RELEVANCE: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Translocação Bacteriana , Coroas , Dente Suporte , Porcelana Dentária
2.
Int J Mol Sci ; 22(2)2021 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-33477311

RESUMO

Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10-4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.


Assuntos
Coroas/microbiologia , Titânio/farmacologia , Zircônio/farmacologia , Carga Bacteriana , Desenho Assistido por Computador , Humanos , Microscopia Eletrônica de Varredura/métodos , Próteses e Implantes/microbiologia
3.
J Esthet Restor Dent ; 31(6): 553-560, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31408272

RESUMO

OBJECTIVE: Late implant placement in volume deficient sites has been considered a challenging situation for the establishment of a natural mucosal topography. Dimensional relations of hard and soft tissues together with the prosthetic components have not been clarified in the literature. The aim of this proof-of-concept case report was to establish the tooth-like appearance with virtual planning prior to surgical intervention and to calculate the ideal amount of desired soft tissue. CLINICAL CONSIDERATIONS: Minimum amount of tissue reconstruction was calculated with computer-aided soft tissue augmentation and a temporary restoration mimicking the emergence profile of a molar was fabricated for guiding the peri-implant mucosa in the early wound healing phase. After 4 months of healing, the final restoration was completed with a screw-retained crown-abutment. The 2-year follow-up period demonstrated a stability of the mucosal margin and peri-implant health. CONCLUSIONS: A natural mucosal contour could be established with the help of virtual planning. The calculation of required tissue quantity may help clinicians for the creation of a natural appearance in late implant placement. CLINICAL SIGNIFICANCE: Virtual soft tissue augmentation may determine the required tissue quantity and therefore, could play an important role in the establishment of natural mucosal contour for late implant placement.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Coroas , Implantação Dentária Endóssea , Dente Molar , Mucosa
4.
BMC Oral Health ; 19(1): 111, 2019 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-31200680

RESUMO

BACKGROUND: The flexibility in designing the submucosal part of CAD/CAM customized implant abutments and the individual positioning of its shoulder line has been suggested to reduce the risk of leaving undetected cement residues, thus preventing adverse effects on peri-implant tissues. A high correlation between excess cement left in the soft tissues and the occurrence of increased biofilm accumulation with sulcular bleeding and/ or suppuration has been reported. This in turn may cause peri-implant inflammation and peri-implant marginal bone loss. The aim of this study was to assess the frequency of cement remnants after the luting of zirconia crowns on CAD/CAM custom molar abutments with different margin levels and to evaluate the impact of the luting material. MATERIAL AND METHODS: A total of 20 titanium molar CAD/CAM implant abutments (BEGO Medical GmbH) with internal taper connection/ internal hex anti-rotation protection, and a convex emergence profile with different margin positions (0, 1, 2 and 3 mm below the mucosa), were virtually designed (Implant Studio, 3Shape) and manufactured. A master cast was scanned, duplicated by a 3D printer and individual gingival masks were produced to simulate peri-implant soft tissues. 20 corresponding zirconia crowns were designed (Cerec 3D, Dentsply Sirona), produced and cemented to the abutments with two different luting materials; a zinc oxide non-eugenol cement (Temp Bond NE) or a methacrylate cement (Panavia V5). To ensure retrievability of the crown/abutment connection, occlusal openings providing access to the abutment screws were designed. Excess cement was thoroughly removed and the crown/abutment units were unscrewed to evaluate the occurrence of cement residues. All the quadrants of each specimen were evaluated for calculation of the ratio between the cement remnant area and the total specimen area using Adobe Photoshop. Spearman analysis was performed to detect correlations between different variables. A two-sided t-test, ANOVA, Mann-Whitney, and Kruskal-Wallis tests were applied to detect differences between the groups. RESULTS: Cement remnants were found in every depth of the crown abutment complex and in almost every area investigated. The amount of cement residues increased as the crown-abutment margin was located more submucosally. Lingual areas were more prone to cement remnants than other surface areas (p = 0.0291). Excess cement was not only found at the margins of the crown-abutment complex, but also underneath (basal) the abutment itself, where cleaning was impossible. No statistical difference in the effect of zinc oxide non-eugenol- and methacrylate cement on the frequency of excess material at the lateral abutment surfaces could be demonstrated in vitro. The proportion of basal abutment aspects covered with cement residues was, however, significantly smaller in Panavia V5 samples with an average of 4.9 ± 3.7% compared to Temp Bond samples with an average of 8.6 ± 5.5%. CONCLUSIONS: Given the results obtained in the present investigation the margin of CAD/CAM molar abutments should be located as coronally as possible to minimize the amount of cement remnants. If an epigingival or supragingival margin location is not feasible due to esthetic concerns, it cannot be recommended to place the margin of molar CAD/CAM abutments deeper than 1.5 mm in the proximal and oral regions.


Assuntos
Cimentação/métodos , Dente Suporte , Projeto do Implante Dentário-Pivô , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Coroas , Cimentos Dentários , Implantes Dentários , Estética Dentária , Humanos , Zircônio
5.
BMC Oral Health ; 18(1): 73, 2018 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-29720149

RESUMO

BACKGROUND: While working on CAD/CAM-customized abutments, the use of standard impression copings with a circular diameter produces inconsistency within the emergence profile. It may begin with a collapse of the supra-implant mucosa during impression taking, then lead to a computer-generated mismatch of the position and outline of the abutment shoulder, and consequently result in a compromised outcome of anticipated treatment. The aim of the study was to compare the virtual and clinical positions of the abutment shoulder in relation to the mucosal margin after the abutment delivery. METHODS: Conventional open-tray impression takings followed uncovering surgery. Master casts were scanned with a desktop scanner. Clinical examinations took place after abutment's insertion and temporization (T1) and prior to cementation of the definitive crown (T2). The distances between the abutment shoulder and marginal soft tissue were measured intraorally in four aspects and juxtaposed with those on the virtual model. RESULTS: The study evaluated 257 dental implants and CAD/CAM-customized abutments. As T1 and T2 showed, there was a positive correlation between the virtually designed abutment shoulder position and matching clinical location relative to the mucosal margin. In 42.1% of cases, the distance between the mucosal margin and the abutment shoulder did not change. It increased in 36.3% of cases while a decrease occurred in 21.6% of them. CONCLUSIONS: Computer-set position of the abutment shoulder in relation to the mucosal margin can be predictably implemented in clinical practice.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Planejamento de Prótese Dentária , Adulto , Idoso , Projeto do Implante Dentário-Pivô , Implantação Dentária Endóssea , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Clin Oral Implants Res ; 28(7): 774-778, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27188407

RESUMO

OBJECTIVE: The aim of this study was to assess the frequency of cement residues after cementation of CAD/CAM monolithic zirconia crowns on customized CAD/CAM titanium abutments. MATERIALS AND METHODS: Sixty premolars and molars were restored on Astra Tech Osseospeed TX™ implants using single monolithic zirconia crowns fixed on two types of custom-made abutments: Atlantis™ titanium or Atlantis™ Gold Hue. Occlusal openings providing access to the abutment screws were designed for retrievability of the crown/abutment connection. After fixation with glass ionomer cement, the crown/abutment units were unscrewed to evaluate the presence of residual cement. Dichotomous assessment of the presence or absence of cement at the crown/abutment unit and peri-implant tissues was performed. RESULTS: Clinically undetected cement excess was visible on 44 of 60 restorations (73.3%). There was no interdependency between residual cement presence and implant location or diameter. However, a dependency between the presence of residual cement and the aspect of the abutment/crown connection could be noted. The majority of the residues were observed on the distal (17.9%) and mesial (15%) aspects. While on the palatal/lingual aspect, the cement was visible in 8.8%; only 3.4% of all surfaces displayed cement residues. CONCLUSIONS: Within the limitations of the study, it can be concluded that the use of customized CAD/CAM abutments do not guarantee avoidance of subgingival cement residues after crown cementation.


Assuntos
Desenho Assistido por Computador , Coroas , Dente Suporte , Cimentos Dentários , Planejamento de Prótese Dentária , Retenção em Prótese Dentária/métodos , Dente Pré-Molar , Feminino , Cimentos de Ionômeros de Vidro/química , Humanos , Masculino , Pessoa de Meia-Idade , Dente Molar , Estudos Prospectivos , Titânio , Zircônio
7.
Int J Implant Dent ; 10(1): 20, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691258

RESUMO

PURPOSE: The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific focus on scan bodies (ISBs). METHODS: Following the PRISMA 2020 guidelines, this study conducted a thorough electronic search across MedLine, PubMed, and Scopus to identify relevant studies. Articles were screened based on titles, abstracts, and full texts for relevance. The Robins I tool assessed the risk of bias in various study types. Data extraction occurred based on predetermined parameters for studying specimens and assessing outcomes. RESULTS: 16 studies met the specified criteria and were consequently included in the systematic review. Due to variations in variables and methods across the selected studies, statistical comparison of results was not feasible. Therefore, a descriptive review approach was chosen, acknowledging the substantial heterogeneity in the reviewed literature. CONCLUSIONS: The precision of virtual scan results is contingent upon diverse characteristics of ISBs and implants. These factors encompass their placement within the dental arch, structural design, shape, material composition, color, and the manufacturing system, all of which contribute to scan accuracy. Additionally, considerations such as the intraoral scanner (IOS) type, scanning technique, use of scan aids, inter-implant distance, scan span, and the number of implants warrant evaluation. In the context of capturing implant positions, intraoral scanning with ISBs demonstrates comparable accuracy to traditional impression methods, particularly in single and short-span scenarios. However, the existing data lacks sufficient information on in vivo applications to formulate clinical recommendations.


Assuntos
Implantes Dentários , Humanos , Imageamento Tridimensional/métodos , Desenho Assistido por Computador , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária/métodos
8.
Int J Oral Maxillofac Implants ; 0(0): 1-24, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38941168

RESUMO

PURPOSE: To retrospectively evaluate the long-term clinical, technical, biological, and esthetic outcomes of implant supported single zirconia crowns (ISCs) intraorally cemented to Ti-base hybrid-abutments up to 16 years after placement. MATERIALS AND METHODS: A total of 63 ISCs (Xive S, Camlog Screw Line, Replace Select TC NP, Branemark MK II, and 3i Osseotite) were evaluated in 36 patients at two different centers. Original Ti-bases were selected and zirconia meso structures and zirconia crowns were designed using CAD/CAM software and then milled from partially stabilized zirconia blocks. After the meso structures were cemented extraorally onto the Ti-bases, the ceramic crowns were intraorally luted to the hybrid abutments. The Ti-base ISC restorations were followed up for up to 16 years, and their clinical, biological, and esthetic outcomes were recorded at distinct time points (T1; T2) at three-year intervals. RESULTS: 36 patients (18 men, 18 women) received 32 ISCs in the anterior region and 31 in the posterior region of the maxilla and mandible. The mean follow-up of the Ti-base ISCs was 6.93 ± 2.60 years. The mean follow-up of the implants amounted to 8.11 ± 3.26 years. No implants were lost during follow-up, resulting in a cumulative implant survival rate of 100%. Abutment screw loosening was observed in two ISCs after one year in service. The overall cumulative restorative survival rate of the Ti-base restorations reached thus 96.83%. At T2 follow-up 24% of the ISCs exhibited an increase in PD despite maintaining clinically healthy peri-implant tissue. An 11% increase in BOP and a 3.17% decrease in PI were recorded. Despite spectrophotometrically measured ΔE values indicating visible discoloration of some restorations and their peri-implant soft tissue, a low incidence of esthetic complications was observed with an average PES/WES score of ≥ 12. No correlation was found between PES (R = -0.25; p = 0.27) and WES (R = -0.18; p = 0.43) scores and digital shade determination. CONCLUSIONS: The results of the present retrospective, multicenter, cohort study indicate satisfactory clinical outcomes for intraorally cemented single zirconia crowns (ISCs) supported by Ti-base hybrid abutments. An overall esthetic superiority of Ti-base ISCs could not be confirmed.

9.
J Adv Prosthodont ; 14(5): 273-284, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36452367

RESUMO

PURPOSE: Computer-aided design and manufacturing (CAD-CAM) of implant abutments has been shown to result in surface contamination from site-specific milling and fabrication processes. If not removed, these contaminants can have a potentially adverse effect and may trigger inflammatory responses of the peri-implant tissues. The aim of the present study was to evaluate the bacterial disinfection and cleaning efficacy of ultrasonic reprocessing in approved disinfectants to reduce the microbial load of CAD-CAM abutments. MATERIALS AND METHODS: Four different types of custom implant abutments (total N = 32) with eight specimens in each test group (type I to IV) were CAD-CAM manufactured. In two separate contamination experiments, specimens were contaminated with heparinized sheep blood alone and with heparinized sheep blood and the test bacterium Enterococcus faecium. Abutments in the test group were processed according to a three-stage ultrasonic protocol and assessed qualitatively and quantitatively by determination of residual protein. Ultrasonicated specimens contaminated with sheep blood and E. faecium were additionally eluted and the dilutions were incubated on agar plates for seven days. The determined bacterial counts were expressed as colony-forming units (CFU). RESULTS: Ultrasonic reprocessing resulted in a substantial decrease in residual bacterial protein to less than 80 µg and a reduction in microbiota of more than 7 log levels of CFU for all abutment types, exceeding the effect required for disinfection. CONCLUSION: A three-stage ultrasonic cleaning and disinfection protocol results in effective bacterial decontamination. The procedure is reproducible and complies with the standardized reprocessing and disinfection specifications for one- or two-piece CAD-CAM implant abutments.

10.
Int J Oral Maxillofac Implants ; 36(4): e91-e96, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34411214

RESUMO

PURPOSE: The objective of this investigation was to assess the extent of mucosal discoloration caused by different CAD/CAM abutment materials and to determine the influence of mucosa thickness on the subsequent color, with a particular focus on titanium nitride. MATERIALS AND METHODS: In a pig maxilla, a trapdoor-shaped mucosa flap was prepared unilaterally. Several CAD/CAM abutment materials were used to assess a number of clinical scenarios. Varying mucosa thicknesses were simulated by connective tissue grafts harvested at the contralateral side of the palate, resulting in layer thicknesses of 1.5, 2, and 3 mm. Titanium (Ti), zirconia (ZrO2), and titanium nitride (TiN) served as test specimens with and without ceramic veneering. Color differences (ΔE) and deviations in brightness (L), chroma (C), and hue (H) were determined spectrophotometrically, comparing the measured value of the native tissue and the results obtained with different materials at varying mucosa thicknesses. RESULTS: All tested specimens caused a mucosa discoloration in comparison to the native tissue, diminishing with increasing mucosa thickness. The use of TiN demonstrated the least mucosa discoloration in thin soft tissue of 1.5 mm, with a mean ΔE value of 1.93 (P = .004). While ZrO2 revealed a comparable ΔE value of 2.13 (P = .022) at a tissue thickness of 1.5 mm, Ti showed the highest mucosa discoloration above the visibility threshold of ΔE = 3.1, with a mean ΔE value of 4.07 (P = .002). Ceramic veneering of the Ti samples led to a considerable reduction in soft tissue discoloration, with a resulting ΔE value of 2.2. The veneering of TiN and ZrO2 samples with porcelain, on the other hand, had no noticeable effect on the mucosa color. CONCLUSION: CAD/CAM abutment materials cause an adverse soft tissue color shift that decreases with increasing mucosa thickness. In thin peri-implant mucosa, titanium nitride and zirconia lead to the least discoloration. Due to their positive optical properties and mechanical superiority compared with ceramic abutments, gold-hue titanium nitride-coated CAD/CAM abutments could be a clinical alternative in cases of thin peri-implant mucosa.


Assuntos
Implantes Dentários para Um Único Dente , Titânio , Animais , Cor , Dente Suporte , Porcelana Dentária , Humanos , Suínos , Zircônio
11.
Int J Oral Maxillofac Implants ; 25(6): 1195-202, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21197498

RESUMO

PURPOSE: The aim of this study was to compare implant-supported restorations placed and loaded immediately or with a delay in a longitudinal case control study. MATERIALS AND METHODS: Seventy-six patients with 222 implants were enrolled in this study. One hundred eleven implants (45 patients) were submitted to immediate functional or nonfunctional loading. These were compared to 111 implants (51 patients) that received delayed loading after submerged healing. The mean observation time was 40.3 months (3.36 years). Implant success was determined, and peri-implant soft tissue parameters and esthetic outcomes for anterior restorations were evaluated. The implants were divided into four groups according to their treatment protocol: immediate (I) or delayed (D) implant placement (P) or function (F), ie: group 1 = IF+IP, group 2 = IF+DP, group 3 = DF+IP, and group 4 = DF+DP. RESULTS: Five implants were lost during healing, giving an overall success rate of 97.7%. Implants with delayed function showed significantly better results (100.0%) than implants that were immediately loaded (95.5%). Four of the five lost implants had been placed immediately postextraction (success rate for delayed implant placement, 99.4%, versus 93.1% for immediate implant placement). Regarding the four treatment protocols, group 1 showed a success rate of 91.3%; group 2 achieved 98.5%; and both delayed function groups showed 100% success. No statistically significant difference was seen between the four groups. Esthetically significant advantages were seen for the implants placed into immediate function. Probing depths and bleeding on probing were significantly lower in the group of implants placed into immediate function. CONCLUSIONS: Implants that are loaded immediately can achieve good outcomes. However, the risk of implant loss appears to be increased in cases where immediate function is combined with immediate implant placement.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários para Um Único Dente , Prótese Dentária Fixada por Implante , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Restauração Dentária Permanente/instrumentação , Restauração Dentária Permanente/métodos , Estética Dentária , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Suporte de Carga , Adulto Jovem
12.
Materials (Basel) ; 13(14)2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32698443

RESUMO

Manufacturing processes of custom implant abutments may contaminate their surfaces with micro wear deposits and generic pollutants. Such particulate debris, if not removed, might be detrimental and provoke inflammatory reactions in peri-implant tissues. Although regulatory guidelines for adequate cleaning, disinfection, or sterilization exist, there does not appear to be a consistent application and data on the amount and extent of such contaminants is lacking. The aim of the present in vitro study was to evaluate the quality and quantity of processing-related surface contamination of computer-aided design/computer-aided manufacturing (CAD/CAM) abutments in the state of delivery and after ultrasonic cleaning. A total of 28 CAD/CAM monotype and hybrid abutments were cleaned and disinfected applying a three-stage ultrasonic protocol (Finevo protocol). Before and after cleaning, the chemical composition and the contamination of the abutments were assessed using scanning electron microscopy (SEM), dispersive X-ray spectroscopy (EDX), and computer-aided planimetric measurement (CAPM). In the delivery condition, monotype abutments showed a significantly higher amount of debris compared to hybrid abutments (4.86 ± 6.10% vs. 0.03 ± 0.03%, p < 0.001). The polishing process applied in the laboratory after bonding the hybrid abutment components reduces the surface roughness and thus contributes substantially to their purity. The extent of contamination caused by computer-aided manufacturing of custom abutments can be substantially minimized using a three-stage ultrasonic protocol.

13.
Environ Toxicol Chem ; 28(10): 2182-90, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19473050

RESUMO

The ventilation amplitude and frequency of silver perch Bidyanus bidyanus, and the ventilation frequency of rainbow fish Melanotaenia duboulayi and rainbow trout Oncorhynchus mykiss, were determined at different temperatures upon exposure to endosulfan and chlorpyrifos, respectively. Silver perch and rainbow fish were tested at 15, 20, 25, 30, and 35 degrees C, while rainbow trout was tested at 10, 15, 20, and 25 degrees C. Although some trend of increasing amplitudes with increasing temperature was evident; there was no significant temperature response of ventilation frequency rates over time in silver perch pre-exposed to 10 microg L(-1) endosulfan for 18 h. The rate of ventilation frequency of rainbow fish pre-exposed to 200 microg L(-1) of chlorpyrifos for 96 h was lower in treatments than in the control at 15 degrees C. However, between 20 and 35 degrees C, rates were significantly higher in the treatments than those of the control. In rainbow trout pre-exposed to 100 microg L(-1) of chlorpyrifos, the rates of frequency were significantly lower than those of controls in temperatures between 10 and 20 degrees C but higher at 25 degrees C. The amplitude of silver perch seemed to increase with the increase in temperature; however, the corresponding temperature quotient values at various temperature regimes and over exposure time showed no significant differences. The ventilation frequency of rainbow fish and rainbow trout significantly increased at the higher test temperatures, and their corresponding temperature quotient values for both fish also increased at the elevated temperatures.


Assuntos
Clorpirifos/farmacologia , Endossulfano/farmacologia , Peixes/fisiologia , Mecânica Respiratória/efeitos dos fármacos , Temperatura , Animais , Técnicas Biossensoriais , Clorpirifos/análise , Biologia Computacional , Simulação por Computador , Endossulfano/análise , Mecânica Respiratória/fisiologia
14.
Int J Implant Dent ; 5(1): 42, 2019 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-31828457

RESUMO

BACKGROUND: There is disagreement about the optimal torque for tightening smartpegs for resonance frequency analysis (RFA). Subjective finger pressure during hand tightening could affect the reliability of the resulting values. The aim of the current study was therefore to assess whether or not the insertion torque of a smartpeg magnetic device influences the implant stability quotient (ISQ) value during RFA. METHODS: Thirty self-tapping screw implants (XiVE S, Dentsply Sirona Implants, Bensheim, Germany) with a diameter of 3.8 mm and a length of 11 mm were inserted in three cow ribs with a bone quality of D1. The RFA value of each implant was measured (Ostell, FA W&H Dentalwerk, Bürmoos, Austria) in two orthogonal directions (mesial and buccal) after tightening the corresponding smartpeg type 45 with a mechanically defined value of 5 Ncm (Meg Torq device, Megagen, Daegu, South Korea) (test). Additionally, 4 different examiners measured the RFA after hand tightening the smartpegs, and the results were compared (control). Insertion torque values were determined by measuring the unscrew torque of hand seated smartpegs (Tohnichi Manufacturing Co. Ltd, Tokyo, Japan). RESULTS: The ISQ values varied from 2 to 11 Ncm by hand tightening and from 2 to 6 Ncm by machine tightening. The comparison of hand and machine tightening of smartpegs displayed only minor differences in the mean ISQ values with low standard deviations (mesial 79.76 ± 2,11, buccal 77.98 ± 2,) and no statistical difference (mesial p = 0,343 and buccal p = 0,890). CONCLUSIONS: Manual tightening of smartpeg transducers allows for an objective and reliable determination of ISQ values during RFA.

15.
In Vivo ; 33(3): 689-698, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31028185

RESUMO

BACKGROUND/AIM: To evaluate the effect of an ultrasonic cleaning and disinfection method for CAD/CAM abutment surfaces on cell viability and inflammatory response in vitro. MATERIALS AND METHODS: Untreated and manually polished surfaces of CAD/CAM generated titanium and zirconia disks were randomly assigned, either to a 3-step ultrasonic cleaning and disinfection process (test: TiUF, TiPF, ZrUF, ZrPF) or to 30 sec steam cleaning (control: TiUS, TiPS, ZrUS, ZrPS). Pre-cleaning surface analyses using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and surface profilometry were performed. Human gingival fibroblasts (HGFs) were cultured on test and control specimens and subsequently examined for cell viability and inflammatory response. Expression of acute inflammatory cytokine interleukin (IL)-6 and vascular endothelial growth factor A (VEGFA) were assessed by means of RT-qPCR. RESULTS: Cells on all specimens exhibited a satisfactory viability, indicating firm attachment. Cells on polished zirconia samples, cleaned by means of sonication (ZrPF), exhibited significantly higher viability than cells on the same material cleaned by steam (ZrPS), p=0.019. For all other three material/ surface treatment combinations (TiU, TiP, ZrU), no such difference was observed between the cleaning methods. The messenger ribonucleic acid (mRNA) levels of IL-6 and VEGFA were between 50 and 105% of that of the control cells on the non-toxic control surface. mRNA levels of IL-6 and VEGFA correlated well with each other. CONCLUSION: Except for higher viability of cells cultured on polished zirconia specimens, no universally applicable advantage could be found for the ultrasonic cleaning procedure for zirconia and titanium abutment surfaces regarding cell viability, IL-6 expression or VEGFA expression. The cleaning procedures did not have any negative effect either.


Assuntos
Sobrevivência Celular , Desenho Assistido por Computador , Desinfecção/métodos , Sonicação , Biomarcadores , Técnicas de Cultura de Células , Desinfecção/instrumentação , Fibroblastos , Expressão Gênica , Humanos , Sonicação/instrumentação , Sonicação/métodos , Propriedades de Superfície
16.
Int J Oral Maxillofac Implants ; 33(4): 808-814, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30024996

RESUMO

PURPOSE: Central manufacturing of two-piece computer-aided design/computer-aided manufacture (CAD/CAM) zirconia abutments may provide a higher accuracy of internal and external adaptation at the expense of delayed restoration delivery. The aim of this study was to compare the fit of two-part zirconia abutments that were either fabricated centrally with the DEDICAM system or at a local laboratory. The field of interest was the marginal, external, and internal luting gap between the titanium insert and CAD/CAM zirconia coping. MATERIALS AND METHODS: Two groups of nine two-piece CAD/CAM zirconia hybrid abutments were subjected to scanning electron microscopy (SEM) to evaluate the precision of fit and thickness of the adhesive joint. Control specimens were fabricated with the CAMLOG DEDICAM system at the manufacturer's site; the test specimens were produced in a local laboratory. After embedding all samples (n = 18) in resin, they were sectioned, and the external, marginal, and internal luting gaps between the titanium base and zirconia coping were measured with SEM. Welch's t test was used for statistical analysis of the obtained data. RESULTS: The overall range of measured gaps between the components of two-piece CAD/CAM zirconia abutments was 0 to 115.5 µm; the mean overall gap size and standard deviation was 45.61 ± 5.88 µm and showed no appreciable difference between the test and control groups. The mean sizes of the marginal/external and internal gaps showed only negligible differences. The internal gap size was generally larger and showed a higher variability than the marginal/external gaps, albeit on a very low level. None of the reported differences between the test and control specimens were statistically significant. CONCLUSION: Luting-gap sizes of CAMLOG DEDICAM- and locally fabricated CAD/CAM zirconia hybrid abutments showed no appreciable difference. Both configurations of two-piece abutments provided a highly precise fit of hybrid components, overmatching the high-quality standards in CAD/CAM implant-based prosthetic dentistry.


Assuntos
Cerâmica , Desenho Assistido por Computador , Dente Suporte , Planejamento de Prótese Dentária , Titânio/química , Zircônio/química , Adaptação Marginal Dentária , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura
17.
J Adv Prosthodont ; 10(3): 197-204, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29930789

RESUMO

PURPOSE: To determine the extent of treatment traces, the roughness depth, and the quantity of titanium nitride (TiN) removed from the surface of CAD/CAM abutments after treatment with various instruments. MATERIALS AND METHODS: Twelve TiN coated CAD/CAM abutments were investigated for an in vitro study. In the test group (9), each abutment surface was subjected twice (150 g vs. 200 g pressure) to standardized treatment in a simulated prophylaxis measure with the following instruments: acrylic scaler, titanium curette, and ultrasonic scaler with steel tip. Three abutments were used as control group. Average surface roughness (Sa) and developed interfacial area ratio (Sdr) of treated and untreated surfaces were measured with a profilometer. The extent of treatment traces were analyzed by scanning electron microscopy. RESULTS: Manipulation with ultrasonic scalers resulted in a significant increase of average surface roughness (Sa, P<.05) and developed interfacial area ratio (Sdr, P<.018). Variable contact pressure did not yield any statistically significant difference on Sa-values for all instruments (P=.8). Ultrasonic treatment resulted in pronounced surface traces and partially detachment of the TiN coating. While titanium curettes caused predominantly moderate treatment traces, no traces or detectable substance removal has been determined after manipulation with acrylic curettes. CONCLUSION: Inappropriate instruments during regular plaque control may have an adverse effect on the integrity of the TiN coating of CAD/CAM abutments. To prevent defects and an increased surface roughness at the transmucosal zone of TiN abutments, only acrylic scaling instruments can be recommended for regular maintenance care.

18.
Environ Toxicol Chem ; 26(7): 1454-9, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17665686

RESUMO

The upper temperature tolerance limits of four freshwater fish species, silver perch Bidyanus bidyanus, eastern rainbowfish Melanotaenia duboulayi, western carp gudgeon Hypseleotris klunzingeri, and rainbow trout Oncorhynchus mykiss, were determined using the critical thermal maximum (CTMaximum) method. The CTMaximum tests were carried out with unexposed fish and fish exposed to sublethal concentrations of endosulfan, chlorpyrifos, and phenol to determine whether or not the CTMaximum was affected. The CTMaximum temperature of B. bidyanus decreased by 2.8, 3.8, and 0.3 degrees C on exposure to endosulfan, chlorpyrifos, and phenol, respectively. Similarly, in M. duboulayi, the CTMaximum was decreased by 4.1, 2.5, and 0 degrees C, while in H. klunzingeri it decreased by 3.1, 4.3, and 0.1degrees C, respectively, and in O. mykiss by 4.8, 5.9, and 0.7 degrees C, respectively. Exposure to sublethal test concentrations of endosulfan and chlorpyrifos caused significant (p < or = 0.0001) reductions in CTMaximum values for all fish species compared to that of unexposed fish. However, exposure to phenol did not cause any significant (p > or = 0.05) change of CTMaximum temperatures.


Assuntos
Adaptação Fisiológica/efeitos dos fármacos , Compostos Orgânicos/toxicidade , Poluentes Químicos da Água/toxicidade , Animais , Peixes , Água Doce , Temperatura
19.
J Periodontol ; 77(1): 73-80, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16579706

RESUMO

BACKGROUND: The aim of the present study in humans was to conduct a comparative immunohistochemical evaluation of vascular endothelial growth factor (VEGF) and nitric oxide synthase (NOS) expression, inflammatory infiltrate, proliferative activity expression, and microvessel density (MVD) in peri-implant soft tissues of titanium and zirconium oxide healing caps. METHODS: Five patients, three men and two women (aged 30 to 66 years; mean: 49 years), participated in this study. All patients received dental implants that were 3.8 mm in diameter and 11 mm in length. All implants were left to heal in a non-submerged (single-stage) mode. Healing caps (3.8 mm in diameter and 3.0 mm in height) were inserted in all implants. Half of the implants were supplied with standard, prefabricated caps of commercially pure titanium, whereas the other half were provided with test zirconium oxide caps. After a 6-month healing period, a gingival biopsy was performed with a circular scalpel (5.5 mm in diameter) around the healing caps of both groups, without unscrewing or removing the healing caps. The dimensions of the gingival biopsies were 1.7 mm (5.5-3.8 mm) in thickness and 3 mm in height. RESULTS: Statistically significant differences were found in the microvessel density between titanium and zirconium oxide healing caps and group II (P < or = 0.0001). Statistically significant differences were likewise found in the low and high intensities of NOS1, NOS3, and VEGF (P < or = 0.0001). In conclusion, the high intensity of NOS1, NOS3, and VEGF were mostly expressed in the titanium group, whereas the low intensity of NOS1, NOS3, and VEGF were mostly expressed in the zirconium oxide group. CONCLUSIONS: In our specimens, the inflammatory infiltrate was mostly present in the titanium specimens. Their extension was much larger than that of the zirconium oxide specimens. Higher values of MVD were observed in the titanium specimens (29.1 versus 15.8). In addition, a higher expression of VEGF intensity was observed in the peri-implant tissues of titanium healing caps, whereas predominantly lower expressions of VEGF intensity were noted around the zirconium oxide healing caps. The Ki-67 expression was higher in the titanium specimens. All these data revealed that the tissues around titanium healing caps underwent a higher rate of inflammation-associated processes, most probably correlated to the higher inflammation processes observed in these tissues. A higher intensity expression of NOS1 and NOS3 was recorded in the tissues around titanium, whereas, on the contrary, a lower intensity of expression was found in the tissues around zirconium oxide specimens. These latter data indicate that the higher expression of these two mediators could be correlated to the higher amount of bacteria present around the titanium samples.


Assuntos
Implantes Dentários , Materiais Dentários , Gengiva/irrigação sanguínea , Antígeno Ki-67/análise , Leucócitos/patologia , Óxido Nítrico Sintase/análise , Titânio , Fator A de Crescimento do Endotélio Vascular/análise , Zircônio , Adulto , Idoso , Biópsia , Proliferação de Células , Implantação Dentária Endóssea/instrumentação , Materiais Dentários/química , Feminino , Seguimentos , Gengiva/patologia , Humanos , Masculino , Microcirculação/patologia , Pessoa de Meia-Idade , Titânio/química , Cicatrização/fisiologia , Zircônio/química
20.
Clin Implant Dent Relat Res ; 8(3): 123-34, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16919020

RESUMO

BACKGROUND: Rigid temporization has been recognized to have a significant impact on the peri-implant tissue response in immediate implant loading since it reduces the mechanical stress exerted on each implant. PURPOSE: A successful protocol for immediate loading of multiple implants depends on an adequate fixation and immobility of the implants to prevent the risk of micromovements in relation to the surrounding bone. The objective of this article was to evaluate a prosthetic concept for an accelerated rigid splinting of multiple implants for same-day immediate loading with metal-reinforced provisional restorations using a technique of welding temporary implant abutments with a prefabricated titanium bar directly in the oral cavity (syncrystallization). MATERIALS AND METHODS: Between June 2004 and January 2005, immediate loading of threaded implants with a metal- reinforced acrylic resin provisional restoration at stage 1 surgery was evaluated in 40 consecutive patients. A total of 192 implants were placed in selected edentulous or partially edentulous patients using the syncrystallization technique. Once the titanium bar was welded intraorally to the abutments, opaque was applied and the provisional restoration was relined and screw-retained the same day. In addition, a comparison of deformations and stress distributions in implant-supported, metal-reinforced and nonmetal-reinforced resin provisional restorations was analyzed in the edentulous mandible by a three-dimensional finite element model (FEM). RESULTS: All of the 192 rigidly temporized immediately loaded implants osseointegrated. An implant success rate of 100% was achieved over a period of 6 months postplacement. No fracture or luting cement failure of the provisional restoration occurred during the observation time. Compared to mere acrylic superstructures, a significant reduction of deformation and strain within metal-reinforced provisional restorations was detected by FEM analysis. CONCLUSION: The results of this study indicate that the syncrystallization technique allows an expedite and adequate rigid splinting of multiple immediately loaded implants. The advantages of the technique are: (1) reduction of treatment time for immediate temporization at stage 1 surgery; (2) predictable fixation and immobility of implants in the early stages of bone healing; and (3) less time for repairing provisional restorations as a result of no or rare fracture.


Assuntos
Resinas Acrílicas , Ligas Dentárias , Implantação Dentária Endóssea/métodos , Implantes Dentários , Prótese Dentária Fixada por Implante , Soldagem em Odontologia/métodos , Planejamento de Dentadura , Resinas Acrílicas/química , Simulação por Computador , Cristalização , Dente Suporte , Ligas Dentárias/química , Restauração Dentária Temporária , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia , Arcada Parcialmente Edêntula/reabilitação , Arcada Parcialmente Edêntula/cirurgia , Mandíbula/fisiopatologia , Osseointegração/fisiologia , Contenções , Estresse Mecânico , Titânio , Resultado do Tratamento