Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Microencapsul ; 37(7): 517-527, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32783663

RESUMO

AIM: Microneedles (MNs) create micropunctures and deliver drugs or nutrients deep into skin layer. We demonstrated that MNs, coated with electrosprayed nanoparticles loaded with functional molecules, are useful for transdermal delivery. METHODS: Electrospraying was utilised to generate drug-loaded nanoparticles and to create uniform coating on MNs. Process parameters and release kinetics were evaluated in vitro. The in vivo efficacy of insulin-coated MNs was investigated using diabetic rats. RESULTS: Electrosprayed micro/nanoparticles loaded with dye or insulin were coated on MNs with particle size of 515 ± 286 and 522 ± 261 nm, respectively. Optimally coated MNs resulted in >70% transfer rate into porcine skins. Insulin-coated MNs were applied to diabetic rats resulting in reduction of blood glucose levels fluctuations, compared to subcutaneous injections. CONCLUSIONS: Electrospraying is shown to be an effective method to coat MNs with drug-loaded nanoparticles. Coated MNs provide a promising platform for cosmetic, drug and protein delivery applications.


Assuntos
Diabetes Mellitus Experimental/tratamento farmacológico , Sistemas de Liberação de Medicamentos/instrumentação , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Nanopartículas/química , Administração Cutânea , Animais , Hipoglicemiantes/farmacocinética , Hipoglicemiantes/uso terapêutico , Insulina/farmacocinética , Insulina/uso terapêutico , Agulhas , Ratos , Ratos Wistar , Pele/metabolismo , Absorção Cutânea
2.
Biomed Microdevices ; 19(3): 64, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28695382

RESUMO

Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window.


Assuntos
Anticoagulantes/farmacologia , Equipamentos para Diagnóstico , Monitoramento de Medicamentos/instrumentação , Dispositivos Lab-On-A-Chip , Papel , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Idoso , Colódio/química , Custos e Análise de Custo , Equipamentos para Diagnóstico/economia , Monitoramento de Medicamentos/economia , Desenho de Equipamento , Feminino , Humanos , Dispositivos Lab-On-A-Chip/economia , Masculino , Membranas Artificiais , Fitas Reagentes/química
3.
Anal Chem ; 87(18): 9315-21, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26255824

RESUMO

Electrospun polyacrylonitrile (PAN) based carbon nanofibers (CNFs) have attracted intense attention due to their easy processing, high carbon yield, and robust mechanical properties. In this work, a CNF modified glassy carbon (GC) electrode that was coated with Nafion polymer was evaluated as a new electrode material for the simultaneous determination of trace levels of heavy metal ions by anodic stripping voltammetry (ASV). Pb(2+) and Cd(2+) were used as a representative system for this initial study. Well-defined stripping voltammograms were obtained when Pb(2+) and Cd(2+) were determined individually and then simultaneously in a mixture. Compared to a bare GC electrode, the CNF/Nafion modified GC (CNF/Nafion/GC) electrode improved the sensitivity for lead detection by 8-fold. The interface properties of the CNF/Nafion/GC were characterized by electrochemical impedance spectroscopy (EIS), which showed the importance of the ratio of CNF/Nafion on electrode performance. Under optimized conditions, the detection limits are 0.9 and 1.5 nM for Pb(2+) and Cd(2+), respectively.

4.
J Biomed Mater Res B Appl Biomater ; 110(3): 660-667, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34596966

RESUMO

Cerebral spinal fluid (CSF) leakage is a major postoperative complication requiring surgical intervention, resulting in prolonged healing and higher costs. Biocompatible polymers, such as cyanoacrylates, are currently used as tissue adhesives for closing surgical defects and incisions. Coupling these polymers with nanofiber technology shows promising results for generating nanofibers used in wound care, tissue engineering, and drug delivery. Fiber membranes formed by electrospinning of n-octyl-2-cyanoacrylate (NOCA) are investigated for in situ dural closures after neurosurgery to improve the quality of the closure and prevent post-surgical CSF leaks. Electrospun NOCA fiber membranes showed significantly higher sealing capabilities of defects in human dura, with an average burst pressure of 149 mmHg, compared with that of an FDA-approved common dural sealant that had an average burst pressure of 37 mmHg. In this study, microfabrication of NOCA fibers demonstrates a promising technique for dural repairs.


Assuntos
Adesivos Teciduais , Vazamento de Líquido Cefalorraquidiano/prevenção & controle , Vazamento de Líquido Cefalorraquidiano/cirurgia , Cianoacrilatos/farmacologia , Dura-Máter/cirurgia , Humanos , Polímeros , Adesivos Teciduais/farmacologia
5.
ACS Omega ; 5(51): 32890-32898, 2020 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-33403250

RESUMO

We have developed a disposable point-of-care (POC) aptamer-based biosensor for the detection of salivary cortisol. Nonstressful and noninvasive sampling of saliva compared to that of blood makes saliva an attractive biological matrix in developing POC devices for biomarker monitoring. Aptamers are attractive as recognition elements for multiple reasons, including their specific chemical synthesis, high stability, lack of immunogenicity, and cell-free evolution. A duplex aptamer conjugated to the surface of Au nanoparticles (AuNPs) by Au-S bonds is utilized as the sensor probe in a lateral flow assay (LFA) device. The addition of saliva samples containing cortisol makes the cortisol-aptamer undergo conformational changes and dissociate from the capture probe. Increasing cortisol concentration in the dispensed saliva sample results in increased dissociation and leads to increased binding of AuNP conjugate on the test line. Therefore, the color intensity of the test line on the LFA is a direct function of the concentration of cortisol in saliva. This simple and fast method provides detection in the cortisol range of ∼0.5-15 ng/mL, which is in the clinically accepted range for salivary cortisol. The limit of detection was 0.37 ng/mL, and the accuracy was confirmed by enzyme-linked immunosorbent assay (ELISA) testing results. High selectivity was observed for salivary cortisol against other closely related steroids and stress biomarkers present in saliva.

6.
Int J Pharm ; 579: 119164, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32081796

RESUMO

Floating gastro-retentive delivery systems can prolong the gastric residence providing sustained drug release. In this study, we report on self-inflating effervescence-based electrospun nanofiber membranes embedding polyethylene oxide/sodium bicarbonate cast films. In this system, sodium bicarbonate results in an effervescence effect by creating carbon dioxide gas upon contacting an acidic gastric fluid, with the resulting gas bubbles being entrapped within the swollen network of nanofibers. Eudragit RL and RS polymers are utilized as a host material to manipulate release kinetics of incorporated drugs. Pramipexole, a common medication for chronic Parkinson's disease (PD), is used as a model drug. Uniform and bead-free nanofibers with diameters of ~300 nm were obtained. Although floating nanofibers initially exhibited high water contact angles (WCA), water droplets were quickly absorbed into the surface and the WCA decreased to ~0° within 60 s. Floating lag time, total floating time, swelling properties and drug release profiles were investigated both in a simulated gastric fluid (pH 1.2 buffer solution) and in a simulated intestinal fluid (pH 6.8 buffer solution) at 37 °C. All floating nanofiber formulations began to float instantly with nearly zero floating lag time and did not sink into the solution even after 24 h. By comparison, the same formulations without sodium bicarbonate cast films could not maintain continuous floating beyond 15 min. The floating nanofiber pouches presented lower initial release of between 20 and 57 %, compared to that of non-floating nanofiber pouches (40-82% within 2 h). Clearly, floating nanofibers reduced the initial burst release and provided sustained drug release. This demonstrates the potential to result in 'once-a-day' oral introduction of drugs that normally must be taken frequently. Effervescence-based floating nanofibers present a novel and promising prototype delivery system for the drug delivery in the upper gastro-intestinal (GI) tract.


Assuntos
Resinas Acrílicas/química , Preparações de Ação Retardada/química , Nanofibras/química , Polietilenoglicóis/química , Polímeros/química , Pramipexol/química , Bicarbonato de Sódio/química , Composição de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos , Nanofibras/ultraestrutura
7.
Chempluschem ; 84(10): 1453-1497, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31943926

RESUMO

The formation of fibers by electrospinning has experienced explosive growth in the past decade, recently reaching 4,000 publications and 1,500 patents per year. This impressive growth of interest is due to the ability to form fibers with a variety of materials, which lend themselves to a large and rapidly expanding set of applications. In particular, coaxial electrospinning, which forms fibers with multiple core-sheath layers from different materials in a single step, enables the combination of properties in a single fiber that are not found in nature in a single material. This article is a detailed review of coaxial electrospinning: basic mechanisms, early history and current status, and an in-depth discussion of various applications (biomedical, environmental, sensors, energy, catalysis, textiles). We aim to provide readers who are currently involved in certain aspects of coaxial electrospinning research an appreciation of other applications and of current results.

8.
Sci Rep ; 9(1): 17936, 2019 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-31784666

RESUMO

Interstitial chemotherapy plays a pivotal role in the treatment of glioblastoma multiforme (GBM), an aggressive form of primary brain cancer, by enhancing drug biodistribution to the tumor and avoiding systemic toxicities. The use of new polymer structures that extend the release of cytotoxic agents may therefore increase survival and prevent recurrence. A novel core-sheath fiber loaded with the drug carmustine (BCNU) was evaluated in an in vivo brain tumor model. Three-dimensional discs were formed from coaxially electrospun fiber membranes and in vitro BCNU release kinetics were measured. In vivo survival was assessed following implantation of discs made of compressed core-sheath fibers (NanoMesh) either concurrently with or five days after intracranial implantation of 9L gliosarcoma. Co-implantation of NanoMesh and 9L gliosarcoma resulted in statistically significant long-term survival (>150 days). Empty control NanoMesh confirmed the safety of these novel implants. Similarly, Day 5 studies showed significant median, overall, and long-term survival rates, suggesting optimal control of tumor growth, confirmed with histological and immunohistochemical analyses. Local chemotherapy by means of biodegradable NanoMesh implants is a new treatment paradigm for the treatment for brain tumors. Drug delivery with coaxial core-sheath structures benefits from high drug loading, controlled long-term release kinetics, and slow polymer degradation. This represents a promising evolution for the current treatment of GBM.


Assuntos
Implantes Absorvíveis , Antineoplásicos/administração & dosagem , Neoplasias Encefálicas/tratamento farmacológico , Preparações de Ação Retardada/química , Sistemas de Liberação de Medicamentos/métodos , Glioblastoma/tratamento farmacológico , Animais , Antineoplásicos/uso terapêutico , Liberação Controlada de Fármacos , Feminino , Membranas Artificiais , Polímeros/química , Ratos , Ratos Endogâmicos F344
9.
J Agric Food Chem ; 66(22): 5635-5643, 2018 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-29750516

RESUMO

Ethylene is a natural aging hormone in plants, and controlling its concentration has long been a subject of research aimed at reducing wastage during packaging, transport, and storage. We report on packaging membranes, produced by electrospinning, that act as efficient carriers for potassium permanganate (PPM), a widely used ethylene oxidant. PPM salt loaded on membranes composed of alumina nanofibers incorporating alumina nanoparticles outperform other absorber systems and oxidize up to 73% of ethylene within 25 min. Membrane absorption of ethylene generated by avocados was totally quenched in 21 h, and a nearly zero ethylene concentration was observed for more than 5 days. By comparison, the control experiments exhibited a concentration of 53% of the initial value after 21 h and 31% on day 5. A high surface area of the alumina nanofiber membranes provides high capacity for ethylene absorption over a long period of time. In combination with other properties, such as planar form, flexibility, ease of handling, and lightweight, these membranes are a highly desirable component of packaging materials engineered to enhance product lifetime.


Assuntos
Óxido de Alumínio/química , Carbono/química , Etilenos/química , Nanopartículas/química , Permanganato de Potássio/química , Adsorção , Etilenos/metabolismo , Embalagem de Alimentos/instrumentação , Frutas/química , Frutas/metabolismo , Membranas Artificiais , Musa/química , Musa/metabolismo
10.
Biomicrofluidics ; 12(1): 014110, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29430275

RESUMO

Increasing numbers of animals are diagnosed with thromboembolism, requiring anticoagulation treatment to prevent thrombotic events. Frequent and periodic coagulation monitoring is critical to ensure treatment effectiveness and patient safety by limiting blood coagulation ability within the desired therapeutic range. Point-of-care diagnostics is an ideal candidate for frequent coagulation monitoring due to rapid test results and no need for laboratory setting. This article reports the first utilization of no-reaction lateral flow assay (nrLFA) device for simple and low-cost animal blood coagulation monitoring in resource-limited setting. The nrLFA device consists of sample pad, analytical membrane and wicking pad, without conjugate pad, reagent printing or membrane drying. Citrated and heparinized animal blood were utilized to mimic different blood coagulation abilities in vitro by adding reversal agents CaCl2 and protamine sulfate. The travel distance of red blood cells (RBCs) on the nrLFA after a pre-determined test time serves as endpoint marker. Upon adding 500 mM CaCl2 solution to citrated bovine, canine, rabbit and equine blood, the average travel distance decreases from 10.9 to 9.4 mm, 8.8 to 5.7 mm, 12.6 to 9 mm, and 15.3 to 11.3 mm, respectively. For heparinized bovine and rabbit blood, the average distance decreases from 14.5 to 11.4 mm and from 9.8 to 7.2 mm, respectively, when adding 300 mg/l protamine sulfate solution. The effect of hematocrit on RBC travel distance in the nrLFA was also investigated. The nrLFA device will potentially improve treatment efficiency, patient safety, quality of life, and satisfaction for both animal patients and their owners.

11.
ACS Appl Mater Interfaces ; 9(49): 42653-42660, 2017 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-29148700

RESUMO

Core-sheath fibers using different Eudragit materials were successfully produced, and their controlled multi-pH responses have been demonstrated. Core-sheath fibers made of Eudragit L 100 (EL100) core and Eudragit S 100 (ES100) sheath provide protection and/or controlled release of core material at pH 6 by adjusting the sheath thickness (controlled by the flow rate of source polymer solution). The thickest sheath (∼250 nm) provides the least core release ∼1.25%/h, while the thinnest sheath (∼140 nm) provides much quicker release ∼16.75%/h. Furthermore, switching core and sheath material dramatically altered the pH response. Core-sheath fibers made of ES100 core and EL100 sheath can provide a consistent core release rate, while the sheath release rate becomes higher as the sheath layer becomes thinner. For example, the thinnest sheath (∼120 nm) provides a core and sheath release ratio of 1:2.5, while the thickest sheath (∼200 nm) shows only a ratio of 1:1.7. All core-sheath Eudragit fibers show no noticeable release at pH 5, while they are completely dissolved at pH 7. Extremely high surface area in the porous network of the fiber membranes provides much faster (>30 times) response to external pH changes as compared to that of equivalent cast films.


Assuntos
Nanofibras , Concentração de Íons de Hidrogênio , Membranas , Polímeros , Porosidade
12.
Acta Biomater ; 53: 242-249, 2017 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-28216302

RESUMO

Electrospun membranes encapsulating nisin in the core of multi-layer coaxial fibers, with a hydrophobic PCL intermediate layer and a hygroscopic cellulose acetate sheath, have been demonstrated to provide long-term antimicrobial activity combined with a hygroscopic outer layer. Antimicrobial performance has been evaluated using modified versions of the antimicrobial textile test AATCC 100 and AATCC 147 against Staphylococcus aureus. The AATCC 147 tests indicate that antimicrobial activity persists up to 7days. The quantitative analysis from the AATCC 100 test indicates that tri-layer coaxial ("triaxial") electrospun fiber membranes provide >99.99% bacteria kill (4logkill) for up to five days. This indicates that the nisin-incorporated triaxial fibers have excellent biocidal activities for up to 5days and then provide biostatic activity for 2 or more days. Compared with other types of electrospun membranes, such as core-sheath coaxial ("coaxial") and single homogenous fibers, triaxial fiber membranes provided more robust and more sustained antimicrobial activity. Single fibers with nisin showed relatively weak activity and only for one day. Coaxial fiber membranes exhibited antimicrobial activity for a long period, but their biocidal activity was much weaker than that of triaxial fiber membranes, and only exhibited >99% bacteria kill (2logkill) after 1day of exposure. STATEMENT OF SIGNIFICANCE: The increase in drug resistant pathogens has driven the need for alternative treatments that are effective against resistant bacteria and do not contribute to drug resistance. Nisin is an excellent model bacteriocin for antimicrobials because of its size and mode of action, and has been extensively used as FDA-approved food preservatives without any problematic resistance growth in bacteria during past decades. Nisin-containing fibers have been previously reported using conventional electrospinning but sustained antimicrobial effect has not been obtained. Here, we report the encapsulation of nisin into a multi-layered nanofiber construct using triaxial electrospinning in order to obtain a long-term antimicrobial activity. This will be highly beneficial in many applications, such as protective textiles, food packaging and cancer therapy.


Assuntos
Fenômenos Fisiológicos Bacterianos/efeitos dos fármacos , Preparações de Ação Retardada/administração & dosagem , Preparações de Ação Retardada/síntese química , Nanofibras/química , Nisina/administração & dosagem , Antibacterianos/administração & dosagem , Antibacterianos/química , Sobrevivência Celular/efeitos dos fármacos , Galvanoplastia/métodos , Membranas Artificiais , Nanofibras/administração & dosagem , Nanofibras/ultraestrutura , Nisina/química , Rotação , Resultado do Tratamento
13.
ACS Appl Mater Interfaces ; 9(13): 11858-11865, 2017 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-28263054

RESUMO

The first self-immolative polymer (SIP) nanofiber membrane is demonstrated in this report, in which the immolation can be triggered by external stimulus. Electrospun SIP/polyacrylonitrile (PAN) fibers provide depolymerization that is ∼25 times quicker and more responsive (i.e., immolation) than that of a cast film in the triggering condition. Depolymerization of SIP in the SIP/PAN blended fiber membrane results in the transition of the surface properties from hydrophobic (∼110°) to hygroscopic (∼0°). Triggered release of encapsulated functional molecules was demonstrated using coaxially electrospun fiber membrane made of a SIP/PAN blend sheath and polyvinylpyrrolidone/dye core. Coaxial fibers with the SIP/PAN sheath provide minimal release of the encapsulated material in nontriggering solution, while it releases the encapsulated material instantly when the triggering condition is met. Its versatility has been strengthened compared to that of non-SIP coaxial fibers that provide no triggering reaction by external stimulus.

14.
J Vis Exp ; (103)2015 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-26381055

RESUMO

Magnetic beads with ~1.9 µm average diameter were used to transport microliter volumes of liquids between contiguous liquid segments with a tube for the purpose of investigating phase change of those liquid segments. The magnetic beads were externally controlled using a magnet, allowing for the beads to bridge the air valve between the adjacent liquid segments. A hydrophobic coating was applied to the inner surface of the tube to enhance the separation between two liquid segments. The applied magnetic field formed an aggregate cluster of magnetic beads, capturing a certain liquid amount within the cluster that is referred to as carry-over volume. A fluorescent dye was added to one liquid segment, followed by a series of liquid transfers, which then changed the fluorescence intensity in the neighboring liquid segment. Based on the numerical analysis of the measured fluorescence intensity change, the carry-over volume per mass of magnetic beads has been found to be ~2 to 3 µl/mg. This small amount of liquid allowed for the use of comparatively small liquid segments of a couple hundred microliters, enhancing the feasibility of the device for a lab-in-tube approach. This technique of applying small compositional variation in a liquid volume was applied to analyzing the binary phase diagram between water and the surfactant C12E5 (pentaethylene glycol monododecyl ether), leading to quicker analysis with smaller sample volumes than conventional methods.


Assuntos
Magnetismo/métodos , Imãs/química , Éteres/química , Corantes Fluorescentes/química , Interações Hidrofóbicas e Hidrofílicas , Dispositivos Lab-On-A-Chip , Magnetismo/instrumentação , Polietilenoglicóis/química , Tensoativos/química , Água/química
15.
ACS Appl Mater Interfaces ; 6(11): 8066-72, 2014 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-24827028

RESUMO

Magnetic beads (MBs) with ∼1.9 µm average diameter were used to transport specific microliter-scale volumes of liquids between adjacent reservoirs within a closed tube under the influence of a magnetic field. The tube's inner surface is coated with a hydrophobic layer, enabling the formation of a surface tension valve by inserting an air gap between reservoirs. This transfer process was implemented by keeping the MBs stationary with a fixed external magnet while the liquid reservoirs were translated by a computer-controlled syringe pump system. The magnet induces the aggregation of MBs in a loosely packed cluster (void volume ∼90-95%) against the tube's inner wall. The liquid trapped in the MB cluster is transported across the air gap between reservoirs. Fluorescence intensity from a dye placed in one reservoir is used to measure the volume of liquid transferred between reservoirs. The carry-over liquid volume is controlled by the mass of the MBs within the device. The typical volume of liquid carried by the MB cluster is ∼2 to 3 µL/mg of beads, allowing the use of small samples. This technique can be used to study the effect of small compositional variation on the properties of fluid mixtures. The feasibility of this "lab-in-tube" approach for binary phase diagram determination in a water-surfactant (C12E5) system was demonstrated.


Assuntos
Magnetismo , Microfluídica/instrumentação , Corantes Fluorescentes/química , Microscopia Eletrônica de Varredura
16.
ACS Appl Mater Interfaces ; 5(16): 8241-5, 2013 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-23924226

RESUMO

A novel dual drug delivery system is presented using triaxial structured nanofibers, which provides different release profiles for model drugs separately loaded in either the sheath or the core of the fiber. Homogenous, coaxial and triaxial fibers containing a combination of materials (PCL, polycaprolactone; PVP, polyvinylpyrrolidone) were fabricated. The drug release profiles were simulated using two color dyes (KAB, keyacid blue; KAU, keyacid uranine), whose release in physiological solution was measured using optical absorption as a function of time. To reach the level of 80% release of encapsulated dye from core, triaxial fibers with a PCL intermediate layer exhibited a ~24× slower release than that from coaxial fibers. At the same time, the hygroscopic sheath layer of the triaxial fibers provided an initial burst release (~ 80% within an hour) of a second dye as high as that from conventional single and coaxial fibers. The triaxial fiber membrane provides both a quick release from the outer sheath layer for short-term treatment and a sustained release from the fiber core for long-term treatment. The intermediate layer between inner core and outer sheath acts as a barrier to prevent leaching from the core, which can be especially important when the membranes are used in wet application. The formation of tri/multiaxially electrospun nanofibrous membranes will be greatly beneficial for biomedical applications by enabling different release profiles of two different drugs from a membrane.


Assuntos
Sistemas de Liberação de Medicamentos , Membranas/química , Nanofibras/química , Povidona/química , Humanos , Poliésteres/química
17.
ACS Appl Mater Interfaces ; 2(1): 252-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20356242

RESUMO

For the purpose of immunoassay, electrospun membranes can be thought as the threadlike self-assembling of nano/microbeads. Nonwoven membranes of electrospun poly(epsilon-caprolactone) (PCL) fibers display excellent tenacity, flexibility and suitable surface energy. These PCL membranes exhibit easy handling in air, fast spreading, and wetting in aqueous solution, and rapid adsorption of protein molecules by hydrophobic interaction. After a fold-and-press process, the membrane porosity was reduced from approximately 75% to less than 10%, whereas the thickness increased from 5.3 to 280 microm. The resulting fluorescence signal from adsorbed protein increased>120x. With anti-HSA and HSA-FITC as an immunoassay model, a linear detection range from 500 ng/mL down to 1 ng/mL is obtained, with a detection of limit (LOD) of approximately 0.08 ng/mL. By comparison, conventional nitrocellulose and a 24.3 microm PCL fiber electrospun membrane displayed a much higher LOD of approximately 100 ng/mL. Immunoassay on free-standing electrospun membrane successfully combines the low-cost and simplicity of conventional membrane immunoassay, with the fast reaction speed and high sensitivity characteristic of magnetic nano/microbeads bioassays.


Assuntos
Anticorpos/química , Membranas Artificiais , Poliésteres/química , Albumina Sérica/análise , Humanos , Técnicas de Imunoadsorção , Sensibilidade e Especificidade , Albumina Sérica/química
18.
Langmuir ; 25(16): 9454-62, 2009 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-19374456

RESUMO

Control of surface wetting properties to produce strongly hydrophobic or hydrophilic effects is at the heart of many macro- and microfluidic applications. In this work, we have investigated coaxial electrospinning to produce core-sheath-structured nano/microfibers that combine different properties from individual core and sheath materials. Teflon AF is an amorphous fluoropolymer that is widely utilized as a hydrophobic material. Hydrophobic fluoropolymers are normally not electrospinnable because their low dielectric constant prevents sufficient charging for a solution to be electrospun. The first Teflon electrospun fibers are reported using coaxial electrospinning with Teflon AF sheath and poly(epsilon-caprolactone) (PCL) core materials. Using these core/sheath fibers, superhydrophobic and oleophobic membranes have been successfully produced. These coaxial fibers also preserve the core material properties as demonstrated with mechanical tensile tests. The fact that a normally nonelectrospinnable material such as Teflon AF has been successfully electrospun when combined with an electrospinnable core material indicates the potential of coaxial electrospinning to provide a new degree of freedom in terms of material combinations for many applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA