Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39172245

RESUMO

OBJECTIVES: Computer vision (CV) mimics human vision, enabling computers to automatically compare radiological images from recent examinations with a large image database for unique identification, crucial in emergency scenarios involving unknown patients or deceased individuals. This study aims to extend a CV-based personal identification method from orthopantomograms (OPGs) to computed tomography (CT) examinations using single CT slices. METHODS: The study analyzed 819 cranial computed tomography (CCT) examinations from 722 individuals, focusing on single CT slices from six anatomical regions to explore their potential for CV-based personal identification in 69 procedures. CV automatically identifies and describes interesting features in images, which can be recognized in a reference image and then designated as matching points. In this study, the number of matching points was used as an indicator for identification. RESULTS: Across six different regions, identification rates ranged from 41/69 (59%) to 69/69 (100%) across over 700 possible identities. Comparison of images from the same individual achieved higher matching points, averaging 6.32 ± 0.52% (100% represents the maximum possible matching points), while images of different individuals averaged 0.94 ± 0.15%. Reliable matching points are found in the teeth, maxilla, cervical spine, skull bones, and paranasal sinuses, with the maxillary sinuses and ethmoidal cells being particularly suitable for identification due to their abundant matching points. CONCLUSION: Unambiguous identification of individuals based on a single CT slice is achievable, with maxillary sinus CT slices showing the highest identification rates. However, metal artifacts, especially from dental prosthetics, and various head positions can hinder identification. CLINICAL RELEVANCE STATEMENT: Radiology possesses a multitude of reference images for a CV database, facilitating automated CV-based personal identification in emergency examinations or cases involving unknown deceased individuals. This enhances patient care and communication with relatives by granting access to medical history. KEY POINTS: Unknown individuals in radiology or forensics pose challenges, addressed through automatic CV-based identification methods. A single CT slice highlighting the maxillary sinuses is particularly effective for personal identification. Radiology plays a pivotal role in automated personal identification by leveraging its extensive image database.

2.
Nanotechnology ; 35(41)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-38744268

RESUMO

The field of nanoscale magnetic resonance imaging (NanoMRI) was started 30 years ago. It was motivated by the desire to image single molecules and molecular assemblies, such as proteins and virus particles, with near-atomic spatial resolution and on a length scale of 100 nm. Over the years, the NanoMRI field has also expanded to include the goal of useful high-resolution nuclear magnetic resonance (NMR) spectroscopy of molecules under ambient conditions, including samples up to the micron-scale. The realization of these goals requires the development of spin detection techniques that are many orders of magnitude more sensitive than conventional NMR and MRI, capable of detecting and controlling nanoscale ensembles of spins. Over the years, a number of different technical approaches to NanoMRI have emerged, each possessing a distinct set of capabilities for basic and applied areas of science. The goal of this roadmap article is to report the current state of the art in NanoMRI technologies, outline the areas where they are poised to have impact, identify the challenges that lie ahead, and propose methods to meet these challenges. This roadmap also shows how developments in NanoMRI techniques can lead to breakthroughs in emerging quantum science and technology applications.

3.
Nature ; 543(7644): 226-228, 2017 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-28277519

RESUMO

The single-atom bit represents the ultimate limit of the classical approach to high-density magnetic storage media. So far, the smallest individually addressable bistable magnetic bits have consisted of 3-12 atoms. Long magnetic relaxation times have been demonstrated for single lanthanide atoms in molecular magnets, for lanthanides diluted in bulk crystals, and recently for ensembles of holmium (Ho) atoms supported on magnesium oxide (MgO). These experiments suggest a path towards data storage at the atomic limit, but the way in which individual magnetic centres are accessed remains unclear. Here we demonstrate the reading and writing of the magnetism of individual Ho atoms on MgO, and show that they independently retain their magnetic information over many hours. We read the Ho states using tunnel magnetoresistance and write the states with current pulses using a scanning tunnelling microscope. The magnetic origin of the long-lived states is confirmed by single-atom electron spin resonance on a nearby iron sensor atom, which also shows that Ho has a large out-of-plane moment of 10.1 ± 0.1 Bohr magnetons on this surface. To demonstrate independent reading and writing, we built an atomic-scale structure with two Ho bits, to which we write the four possible states and which we read out both magnetoresistively and remotely by electron spin resonance. The high magnetic stability combined with electrical reading and writing shows that single-atom magnetic memory is indeed possible.

4.
Nano Lett ; 22(23): 9766-9772, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36317830

RESUMO

Hyperfine interactions have been widely used in material science, organic chemistry, and structural biology as a sensitive probe to local chemical environments. However, traditional ensemble measurements of hyperfine interactions average over a macroscopic number of spins with different geometrical locations and nuclear isotopes. Here, we use a scanning tunneling microscope (STM) combined with electron spin resonance (ESR) to measure hyperfine spectra of hydrogenated-Ti on MgO/Ag(100) at low-symmetry binding sites and thereby determine the isotropic and anisotropic hyperfine interactions at the single-atom level. Combining vector-field ESR spectroscopy with STM-based atom manipulation, we characterize the full hyperfine tensors of 47Ti and 49Ti and identify significant spatial anisotropy of the hyperfine interactions for both isotopes. Density functional theory calculations reveal that the large hyperfine anisotropy arises from highly anisotropic distributions of the ground-state electron spin density. Our work highlights the power of ESR-STM-enabled single-atom hyperfine spectroscopy in revealing electronic ground states and atomic-scale chemical environments.


Assuntos
Anisotropia , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Sítios de Ligação
5.
Eur Radiol ; 32(1): 424-431, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34327575

RESUMO

OBJECTIVES: The aim of this study was to evaluate the sensitivity of CT-based thermometry for clinical applications regarding a three-component tissue phantom of fat, muscle and bone. Virtual monoenergetic images (VMI) by dual-energy measurements and conventional polychromatic 120-kVp images with modern reconstruction algorithms adaptive statistical iterative reconstruction-Volume (ASIR-V) and deep learning image reconstruction (DLIR) were compared. METHODS: A temperature-regulating water circuit system was developed for the systematic evaluation of the correlation between temperature and Hounsfield units (HU). The measurements were performed on a Revolution CT with gemstone spectral imaging technology (GSI). Complementary measurements were performed without GSI (voltage 120 kVp, current 130-545 mA). The measured object was a tissue equivalent phantom in a temperature range of 18 to 50°C. The evaluation was carried out for VMI at 40 to 140 keV and polychromatic 120-kVp images. RESULTS: The regression analysis showed a significant inverse linear dependency between temperature and average HU regardless of ASIR-V and DLIR. VMI show a higher temperature sensitivity compared to polychromatic images. The temperature sensitivities were 1.25 HU/°C (120 kVp) and 1.35 HU/°C (VMI at 140 keV) for fat, 0.38 HU/°C (120 kVp) and 0.47 HU/°C (VMI at 40 keV) for muscle and 1.15 HU/°C (120 kVp) and 3.58 HU/°C (VMI at 50 keV) for bone. CONCLUSIONS: Dual-energy with VMI enables a higher temperature sensitivity for fat, muscle and bone. The reconstruction with ASIR-V and DLIR has no significant influence on CT-based thermometry, which opens up the potential of drastic dose reductions. KEY POINTS: • Virtual monoenergetic images (VMI) enable a higher temperature sensitivity for fat (8%), muscle (24%) and bone (211%) compared to conventional polychromatic 120-kVp images. • With VMI, there are parameters, e.g. monoenergy and reconstruction kernel, to modulate the temperature sensitivity. In contrast, there are no parameters to influence the temperature sensitivity for conventional polychromatic 120-kVp images. • The application of adaptive statistical iterative reconstruction-Volume (ASIR-V) and deep learning-based image reconstruction (DLIR) has no effect on CT-based thermometry, opening up the potential of drastic dose reductions in clinical applications.


Assuntos
Aprendizado Profundo , Termometria , Algoritmos , Humanos , Músculos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
6.
Eur Radiol ; 31(6): 4298-4307, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33277671

RESUMO

OBJECTIVES: The implant constructs used in scoliosis surgery are often long with a high screw density. Therefore, it is generally believed that magnetic resonance imaging (MRI) should not be carried out after scoliosis surgery, with the result that computed tomography is often preferred despite the ionizing radiation involved. The objective of this study was to evaluate the MRI compatibility of long pedicle-screw-rod constructs at 1.5 T and 3 T using standardized methods of the American Society for Testing and Materials (ASTM). METHODS: Constructs between 130 and 430 mm long were systematically examined according to the ASTM standards F2182 (radio frequency-induced heating), F2119 (susceptibility artifacts), F2213 (magnetically induced torque), and F2052 (magnetically induced displacement force). RESULTS: The maximum heating in the magnetic field was 1.3 K. Heating was significantly influenced by magnetic field strength (p < 0.001), implant length (p = 0.048), and presence of cross-links (p = 0.001). The maximum artifact width for different lengths of the anatomically bent titanium rods with CoCr alloy ranged between 14.77 ± 2.93 mm (TSE) and 17.49 ± 1.82 mm (GRE) for 1.5 T and between 23.67 ± 2.39 mm (TSE) and 27.77 ± 2.37 mm (GRE) for 3 T. TiCP and TiAl showed the smallest and CoCr and CoCr Plus the largest artifact widths. The magnetically induced torque and displacement force were negligible. CONCLUSIONS: MRI following scoliosis surgery with long implant constructs is safe with the patient in supine position. Although susceptibility artifacts can severely limit the diagnostic value, the examination of other regions is possible. KEY POINTS: • Large spinal implants are not necessarily a contraindication for MRI; MR conditional status can be examined according to the ASTM standards F2182, F2119, F2213, and F2052. • A metallic pedicle-screw-rod system could be reliably and safely examined in all combinations of length (130 to 430 mm), configuration, and material in a B0 at 1.5 T and 3 T. • According to ASTM F2503, the examined pedicle-screw-rod system is MR conditional and especially the young patients can benefit from a non-ionizing radiation MRI examination.


Assuntos
Artefatos , Escoliose , Calefação , Humanos , Imageamento por Ressonância Magnética , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Torque
7.
Unfallchirurg ; 124(5): 362-365, 2021 May.
Artigo em Alemão | MEDLINE | ID: mdl-33638014

RESUMO

Due to the airborne transmission of the coronavirus disease 2019 (COVID 19) via aerosols or microdroplets, this study investigated the effect of a mobile air filter system in a surgical examination room. The use of the air filter system led to a significant reduction of aerosols in the room. Therefore the use of a high efficiency air filtration device, in examination rooms with poor ventilation, e.g. lack of windows or local exhaust, is mandatory.


Assuntos
Filtros de Ar , COVID-19 , Aerossóis , Humanos , Pandemias , SARS-CoV-2
8.
Phys Rev Lett ; 124(16): 167202, 2020 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-32383899

RESUMO

The magnetic moment of rare earth elements originates from electrons in the partially filled 4f orbitals. Accessing this moment electrically by scanning tunneling spectroscopy is hampered by shielding of outerlying orbitals. Here, we show that we can detect the magnetic moment of an individual Ce atom adsorbed on a Cu_{2}N ultrathin film on Cu(100) by using a sensor tip that has its apex functionalized with a Kondo screened spin system. We calibrate the sensor tip by deliberately coupling it to a well characterized Fe atom. Subsequently, we use the splitting of the tip's Kondo resonance when approaching a spectroscopically dark Ce atom to sense its magnetic moment.

9.
Nano Lett ; 19(11): 8201-8206, 2019 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-31661282

RESUMO

Spin resonance of single spin centers bears great potential for chemical structure analysis, quantum sensing, and quantum coherent manipulation. Essential for these experiments is the presence of a two-level spin system whose energy splitting can be chosen by applying a magnetic field. In recent years, a combination of electron spin resonance (ESR) and scanning tunneling microscopy (STM) has been demonstrated as a technique to detect magnetic properties of single atoms on surfaces and to achieve sub-microelectronvolts energy resolution. Nevertheless, up to now the role of the required magnetic fields has not been elucidated. Here, we perform single-atom ESR on individual Fe atoms adsorbed on magnesium oxide (MgO) using a two-dimensional vector magnetic field as well as the local field of the magnetic STM tip in a commercially available STM. We show how the ESR amplitude can be greatly improved by optimizing the magnetic fields, revealing in particular an enhanced signal at large in-plane magnetic fields. Moreover, we demonstrate that the stray field from the magnetic STM tip is a versatile tool. We use it here to drive the electron spin more efficiently and to perform ESR measurements at constant frequency by employing tip-field sweeps. Lastly, we show that it is possible to perform ESR using only the tip field, under zero external magnetic field, which promises to make this technique available in many existing STM systems.

10.
Phys Rev Lett ; 122(22): 227203, 2019 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-31283288

RESUMO

Shrinking spintronic devices to the nanoscale ultimately requires localized control of individual atomic magnetic moments. At these length scales, the exchange interaction plays important roles, such as in the stabilization of spin-quantization axes, the production of spin frustration, and creation of magnetic ordering. Here, we demonstrate the precise control of the exchange bias experienced by a single atom on a surface, covering an energy range of 4 orders of magnitude. The exchange interaction is continuously tunable from milli-eV to micro-eV by adjusting the separation between a spin-1/2 atom on a surface and the magnetic tip of a scanning tunneling microscope. We seamlessly combine inelastic electron tunneling spectroscopy and electron spin resonance to map out the different energy scales. This control of exchange bias over a wide span of energies provides versatile control of spin states, with applications ranging from precise tuning of quantum state properties, to strong exchange bias for local spin doping. In addition, we show that a time-varying exchange interaction generates a localized ac magnetic field that resonantly drives the surface spin. The static and dynamic control of the exchange interaction at the atomic scale provides a new tool to tune the quantum states of coupled-spin systems.

11.
Contact Dermatitis ; 80(1): 45-53, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30246346

RESUMO

BACKGROUND: The CARPE registry was set up in 2009 to prospectively investigate the management of patients with chronic hand eczema (CHE). OBJECTIVES: To report comprehensive follow-up data from the CARPE registry. PATIENTS AND METHODS: We investigated sociodemographic and clinical characteristics, provision of medical care, physician-assessed outcomes, and patient-reported outcomes (PROs). Data were collected between 2009 and 2016, with up to 5 years of follow-up, and are reported descriptively. RESULTS: Overall, 1281 patients were included in the registry (53.7% female). Mean age was 47.0 years. Of the patients, 793 and 231 completed the 2-year follow-up and 5-year follow-up, respectively. At baseline, 5.4% had changed or given up their job because of CHE, the average duration of CHE was 6.1 years, and, in 22.4%, the CHE was severe according to physician global assessment. Systemic treatment (alitretinoin, acitretin, and methotrexate) was prescribed at least once to 39.0% of the patients during the course of the follow-up. Disease severity, quality of life and treatment satisfaction improved over time, and the proportion of patients receiving systemic treatments decreased. CONCLUSIONS: Under continued dermatological care, substantial improvements in disease severity and PROs over time was achieved during the course of the CARPE registry, even in patients with long-standing and severe hand eczema.


Assuntos
Dermatite Alérgica de Contato/fisiopatologia , Dermatoses da Mão/fisiopatologia , Sistema de Registros , Acitretina/uso terapêutico , Administração Cutânea , Adolescente , Corticosteroides/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Alitretinoína/uso terapêutico , Doença Crônica , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/terapia , Fármacos Dermatológicos/uso terapêutico , Eczema/fisiopatologia , Feminino , Seguimentos , Dermatoses da Mão/terapia , Humanos , Masculino , Metotrexato/uso terapêutico , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Terapia PUVA , Medidas de Resultados Relatados pelo Paciente , Terapia Ultravioleta , Ureia/uso terapêutico , Adulto Jovem
12.
Sensors (Basel) ; 19(24)2019 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-31842298

RESUMO

A low-drift fiber-optic sensor system, consisting of 24 regenerated fiber Bragg gratings (RFBG), equally distributed over a length of 2.3 m, is presented here. The sensor system can monitor spatially extended temperature profiles with a time resolution of 1 Hz at temperatures of up to 500 °C. The system is intended to be used in chemical reactors for both the control of the production ramp-up, where a fast time response is needed, as well as for production surveillance, where low sensor drifts over several years are required. The fiber-optic sensor system was installed in a pilot test reactor and was exposed to a constant temperature profile, with temperatures in the range of 150-500 °C for more than two years. During this period, the temperature profile was measured every three to five months and the fiber-optic temperature data were compared with data from a three-point thermocouple array and a calibrated single-point thermocouple. A very good agreement between all temperature measurements was found. The drift rates of the 24 RFBG sensor elements were determined by comparing the Bragg wavelengths at a precisely defined reference temperature near room temperature before and after the two-year deployment. They were found to be in the range of 0.0 K/a to 2.3 K/a, with an average value of 1.0 K/a. These low drift rates were achieved by a dedicated temperature treatment of the RFBGs during fabrication. Here, the demonstrated robustness, accuracy, and low drift characteristics show the potential of fiber-optic sensors for future industrial applications.

13.
Int J Legal Med ; 132(2): 563-577, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29335777

RESUMO

Post-mortem body cooling is the foundation of temperature-based death time estimations (TDE) in homicide cases. Forensic science generally provides two types of p.m. body cooling models, the phenomenological and the physical models. Since both of them have to implement important individual parameters like the quantity of abdominal fat explicitly or implicitly, a more exact quantification and localization of abdominal fat is a desideratum in TDE. Particularly for the physical models, a better knowledge of the abdominal fat distribution could lead to relevant improvements in TDEs. Modern imaging methods in medicine like computed tomography (CT) are opening up the possibility to register the quantity and spatial distribution of body fat in individual cases with unprecedented precision. Since a CT-scan of an individual's abdominal region can comprise 1000 slices as an order of magnitude, it is evident that their evaluation for body fat quantification and localization needs fully automated algorithms. The paper at hand describes the development and validation of such an algorithm called "CT-histogram-based fat estimation and quasi-segmentation" (CFES). The approach can be characterized as a weighted least squares method dealing with the gray value histogram of single CT-slices only. It does not require any anatomical a priori information nor does it perform time-consuming feature detection on the CT-images. The processing result consists in numbers quantifying the amount of abdominal body fat and of muscle-, organ-, and connective tissue. As a by-product, CFES generates a quasi-segmentation of the slices processed differentiating fat from muscle-, organ-, and connective tissue. The tool is validated on synthetic data and on CT-data of a special phantom. It was also applied on a CT-scan of a dead body, where it produced anatomically plausible results.


Assuntos
Gordura Abdominal/diagnóstico por imagem , Algoritmos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Adulto , Temperatura Corporal , Patologia Legal , Humanos , Análise dos Mínimos Quadrados , Masculino , Mudanças Depois da Morte
14.
Phys Rev Lett ; 119(22): 227206, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29286811

RESUMO

Quantum spin networks having engineered geometries and interactions are eagerly pursued for quantum simulation and access to emergent quantum phenomena such as spin liquids. Spin-1/2 centers are particularly desirable, because they readily manifest coherent quantum fluctuations. Here we introduce a controllable spin-1/2 architecture consisting of titanium atoms on a magnesium oxide surface. We tailor the spin interactions by atomic-precision positioning using a scanning tunneling microscope (STM) and subsequently perform electron spin resonance on individual atoms to drive transitions into and out of quantum eigenstates of the coupled-spin system. Interactions between the atoms are mapped over a range of distances extending from highly anisotropic dipole coupling to strong exchange coupling. The local magnetic field of the magnetic STM tip serves to precisely tune the superposition states of a pair of spins. The precise control of the spin-spin interactions and ability to probe the states of the coupled-spin network by addressing individual spins will enable the exploration of quantum many-body systems based on networks of spin-1/2 atoms on surfaces.

15.
Phys Rev Lett ; 119(22): 227001, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29286823

RESUMO

We explore a new mechanism for switching magnetism and superconductivity in a magnetically frustrated iron-based superconductor using spin-polarized scanning tunneling microscopy (SPSTM). Our SPSTM study on single-crystal Sr_{2}VO_{3}FeAs shows that a spin-polarized tunneling current can switch the Fe-layer magnetism into a nontrivial C_{4} (2×2) order, which cannot be achieved by thermal excitation with an unpolarized current. Our tunneling spectroscopy study shows that the induced C_{4} (2×2) order has characteristics of plaquette antiferromagnetic order in the Fe layer and strongly suppresses superconductivity. Also, thermal agitation beyond the bulk Fe spin ordering temperature erases the C_{4} state. These results suggest a new possibility of switching local superconductivity by changing the symmetry of magnetic order with spin-polarized and unpolarized tunneling currents in iron-based superconductors.

16.
Int J Legal Med ; 131(3): 699-712, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28091724

RESUMO

Temperature-based death time estimation is based either on simple phenomenological models of corpse cooling or on detailed physical heat transfer models. The latter are much more complex but allow a higher accuracy of death time estimation, as in principle, all relevant cooling mechanisms can be taken into account.Here, a complete workflow for finite element-based cooling simulation is presented. The following steps are demonstrated on a CT phantom: Computer tomography (CT) scan Segmentation of the CT images for thermodynamically relevant features of individual geometries and compilation in a geometric computer-aided design (CAD) model Conversion of the segmentation result into a finite element (FE) simulation model Computation of the model cooling curve (MOD) Calculation of the cooling time (CTE) For the first time in FE-based cooling time estimation, the steps from the CT image over segmentation to FE model generation are performed semi-automatically. The cooling time calculation results are compared to cooling measurements performed on the phantoms under controlled conditions. In this context, the method is validated using a CT phantom. Some of the phantoms' thermodynamic material parameters had to be determined via independent experiments.Moreover, the impact of geometry and material parameter uncertainties on the estimated cooling time is investigated by a sensitivity analysis.


Assuntos
Simulação por Computador , Análise de Elementos Finitos , Mudanças Depois da Morte , Desenho Assistido por Computador , Estudos de Viabilidade , Humanos , Modelos Biológicos , Tomografia Computadorizada Multidetectores , Imagens de Fantasmas
17.
Nano Lett ; 15(8): 5388-92, 2015 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-26121366

RESUMO

Understanding the principles of molecular recognition is a difficult task and calls for investigation of appropriate model systems. Using the manipulation capabilities of scanning tunneling microscopy (STM) we analyzed the chiral recognition in self-assembled dimers of helical hydrocarbons at the single molecule level. After manual separation of the two molecules of a dimer with a molecule-terminated STM tip on a Cu(111) surface, their handedness was subsequently determined with a metal atom-terminated tip. We find that these molecules strongly prefer to form heterochiral pairs. Our study shows that single molecule manipulation is a valuable tool to understand intermolecular recognition at surfaces.

18.
Phys Rev Lett ; 114(7): 076601, 2015 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-25763966

RESUMO

Spin-resolved scanning tunneling microscopy is employed to quantitatively determine the spin polarization of the magnetic field-split Kondo state. Tunneling conductance spectra of a Kondo-screened magnetic atom are evaluated within a simple model taking into account inelastic tunneling due to spin excitations and two Kondo peaks positioned symmetrically around the Fermi energy. We fit the spin state of the Kondo-screened atom with a spin Hamiltonian independent of the Kondo effect and account for Zeeman splitting of the Kondo peak in the magnetic field. We find that the width and the height of the Kondo peaks scales with the Zeeman energy. Our observations are consistent with full spin polarization of the Kondo peaks, i.e., a majority spin peak below the Fermi energy and a minority spin peak above.

19.
Sci Rep ; 14(1): 4195, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38379027

RESUMO

Computer Vision (CV)-based human identification using orthopantomograms (OPGs) has the potential to identify unknown deceased individuals by comparing postmortem OPGs with a comprehensive antemortem CV database. However, the growing size of the CV database leads to longer processing times. This study aims to develop a standardized and reliable Convolutional Neural Network (CNN) for age estimation using OPGs and integrate it into the CV-based human identification process. The CNN was trained on 50,000 OPGs, each labeled with ages ranging from 2 to 89 years. Testing included three postmortem OPGs, 10,779 antemortem OPGs, and an additional set of 70 OPGs within the context of CV-based human identification. Integrating the CNN for age estimation into CV-based human identification process resulted in a substantial reduction of up to 96% in processing time for a CV database containing 105,251 entries. Age estimation accuracy varied between postmortem and antemortem OPGs, with a mean absolute error (MAE) of 2.76 ± 2.67 years and 3.26 ± 3.06 years across all ages, as well as 3.69 ± 3.14 years for an additional 70 OPGs. In conclusion, the incorporation of a CNN for age estimation in the CV-based human identification process significantly reduces processing time while delivering reliable results.


Assuntos
Aprendizado Profundo , Humanos , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Antropologia Forense , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Computadores
20.
ACS Nano ; 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39382840

RESUMO

Recent advances in scanning probe microscopy combined with electron spin resonance have revealed that localized electron spins on or near surfaces can be utilized as building blocks for the bottom-up assembly of functional quantum-coherent nanostructures. In this perspective, we review the recent advances, lay out advantages of this platform and outline the challenges that lie ahead on the way to the application of on-surface atomic spins to quantum information science and quantum computing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA