Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Microbiol ; 62(2): e0127523, 2024 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-38193685

RESUMO

The mpox pandemic necessitated the rapid development of clinical assays for monkeypox virus detection. While the majority of mpox specimens have high viral loads with corresponding early cycle threshold (CT) values, reports have indicated some specimens with late CT values can represent false positive results. To mitigate this risk, the Centers for Disease Control and Prevention (CDC) published an advisory recommending repeat testing of all specimens with CT values ≥34. However, limited experimental data were available to support this specific cutoff. In this study, we examine whether a more conservative approach in which all specimens with CT values ≥29 are repeated would improve the detection of potential false positive results. Compared to the CDC algorithm, our approach identified an additional 20% (5/25) of potential false positive results. To assess the impact of this cutoff on laboratory workload, we modeled the expected increase in test volume and turnaround time (TAT) relative to the CDC method. Using a lower repeat threshold, test volume increased by 0.7% while mean TAT increased by less than 15 minutes. Overall, a lower threshold than recommended by the CDC for repeating late CT mpox specimens may reduce the number of false positives reported while minimally impacting testing volume and TAT.


Assuntos
Mpox , Estados Unidos , Humanos , Algoritmos , Bioensaio , Centers for Disease Control and Prevention, U.S. , Laboratórios
2.
J Clin Microbiol ; 61(12): e0082923, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38092673

RESUMO

Cytomegalovirus (CMV) resistance testing by targeted next-generation sequencing (NGS) allows for the simultaneous analysis of multiple genes. We developed and validated an amplicon-based Ion Torrent NGS assay to detect CMV resistance mutations in UL27, UL54, UL56, and UL97 and compared the results to standard Sanger sequencing. NGS primers were designed to generate 83 overlapping amplicons of four CMV genes (~10 kb encompassing 138 mutation sites). An open-access software plugin was developed to perform read alignment, call variants, and interpret drug resistance. Plasmids were tested to determine NGS error rate and minor variant limit of detection. NGS limit of detection was determined using the CMV WHO International Standard and quantified clinical specimens. Reproducibility was also assessed. After establishing quality control metrics, 185 patient specimens previously tested using Sanger were reanalyzed by NGS. The NGS assay had a low error rate (<0.05%) and high accuracy (95%) for detecting CMV-associated resistance mutations present at ≥5% in contrived mixed populations. Mutation sites were reproducibly sequenced with 40× coverage when plasma viral loads were ≥2.6 log IU/mL. NGS detected the same resistance-associated mutations identified by Sanger in 68/69 (98.6%) specimens. In 16 specimens, NGS detected 18 resistance mutations that Sanger failed to detect; 14 were low-frequency variants (<20%), and six would have changed the drug resistance interpretation. The NGS assay showed excellent agreement with Sanger and generated high-quality sequence from low viral load specimens. Additionally, the higher resolution and analytic sensitivity of NGS potentially enables earlier detection of antiviral resistance.


Assuntos
Infecções por Citomegalovirus , Citomegalovirus , Humanos , Citomegalovirus/genética , Reprodutibilidade dos Testes , Mutação , Infecções por Citomegalovirus/diagnóstico , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Farmacorresistência Viral/genética
3.
J Clin Microbiol ; 60(7): e0025322, 2022 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-35699434

RESUMO

HIV-1 antiretroviral therapy management requires sequencing the protease, reverse transcriptase, and integrase portions of the HIV-1 pol gene. Most resistance testing is performed with Sanger sequencing, which has limited ability to detect minor variants. Next generation sequencing (NGS) platforms enable variant detection at frequencies as low as 1% allowing for earlier detection of resistance and modification of therapy. Implementation of NGS assays in the clinical laboratory is hindered by complicated assay design, cumbersome wet bench procedures, and the complexity of data analysis and bioinformatics. We developed a complete NGS protocol and companion analysis and reporting pipeline using AmpliSeq multiplex PCR, Ion Torrent S5 XL sequencing, and Stanford's HIVdb resistance algorithm. Implemented as a Torrent Suite software plugin, the pipeline runs automatically after sequencing. An optimum variant frequency threshold of 10% was determined by comparing Sanger sequences of archived samples from ViroSeq testing, resulting in a sensitivity of 98.2% and specificity of 99.0%. The majority (91%) of drug resistance mutations were detected by both Sanger and NGS, with 1.7% only by Sanger and 7.3% only by NGS. Variant calls were highly reproducible and there was no cross-reactivity to VZV, HBV, CMV, EBV, and HCV. The limit of detection was 500 copies/mL. The NGS assay performance was comparable to ViroSeq Sanger sequencing and has several advantages, including a publicly available end-to-end analysis and reporting plugin. The assay provides a straightforward path for implementation of NGS for HIV drug resistance testing in the laboratory setting without additional investment in bioinformatics infrastructure and resources.


Assuntos
Infecções por HIV , Soropositividade para HIV , HIV-1 , Farmacorresistência Viral/genética , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , HIV-1/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Mutação , Software , Carga Viral
4.
J Clin Microbiol ; 58(3)2020 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-31852765

RESUMO

The incidence of tick-borne infections in the United States has risen significantly in the past decade. Ticks can transmit a variety of pathogens, including bacteria, protozoa, and viruses, that can cause serious illnesses. Therefore, the use of rapid, sensitive, and specific multiplex tests is important to identify the pathogen(s) in the acute phase and determine appropriate treatment to minimize the severity of the disease. The purpose of this study was to evaluate ChromaCode's research use only (RUO) nine-target high-definition PCR (HDPCR) tick-borne pathogen (TBP) panel using 379 retrospective, remnant whole-blood and synovial fluid specimens previously submitted to Associated Regional and University Pathologists (ARUP) Laboratories and tested by clinically validated real-time PCR assays for Ehrlichia spp., Anaplasma phagocytophilum, Babesia spp., or Lyme Borrelia spp. The performance characteristics evaluated included positive percent agreement (PPA) and negative percent agreement (NPA) with the ARUP laboratory-developed tests (LDTs). All tested targets had an initial PPA greater than 97.0%, except Ehrlichia ewingii, with a PPA of 88.9%. The NPAs for all targets were between 98.8% and 100%. The TBP panel detected three coinfections, with two of Babesia microti and A. phagocytophilum and one of B. microti and E. chaffeensis, which were confirmed by the LDTs. There were 16 samples with discordant results compared to the LDT results, five of which were resolved by repeat testing on the TBP panel and bidirectional sequencing. Following discrepant resolution, the final PPA and NPA for the TBP panel were 97.7% (95% confidence interval [CI], 95.2% to 99.0%) and 99.6% (95% CI, 99.3% to 99.8%), respectively, with an overall agreement of 99.5% (95% CI, 99.2% to 99.7%) with the LDTs.


Assuntos
Anaplasma phagocytophilum , Babesia microti , Borrelia , Doenças Transmitidas por Carrapatos , Anaplasma phagocytophilum/genética , Animais , Babesia microti/genética , Borrelia/genética , Humanos , Estudos Retrospectivos , Doenças Transmitidas por Carrapatos/diagnóstico
5.
N Engl J Med ; 372(9): 835-45, 2015 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-25714161

RESUMO

BACKGROUND: Incidence estimates of hospitalizations for community-acquired pneumonia among children in the United States that are based on prospective data collection are limited. Updated estimates of pneumonia that has been confirmed radiographically and with the use of current laboratory diagnostic tests are needed. METHODS: We conducted active population-based surveillance for community-acquired pneumonia requiring hospitalization among children younger than 18 years of age in three hospitals in Memphis, Nashville, and Salt Lake City. We excluded children with recent hospitalization or severe immunosuppression. Blood and respiratory specimens were systematically collected for pathogen detection with the use of multiple methods. Chest radiographs were reviewed independently by study radiologists. RESULTS: From January 2010 through June 2012, we enrolled 2638 of 3803 eligible children (69%), 2358 of whom (89%) had radiographic evidence of pneumonia. The median age of the children was 2 years (interquartile range, 1 to 6); 497 of 2358 children (21%) required intensive care, and 3 (<1%) died. Among 2222 children with radiographic evidence of pneumonia and with specimens available for bacterial and viral testing, a viral or bacterial pathogen was detected in 1802 (81%), one or more viruses in 1472 (66%), bacteria in 175 (8%), and both bacterial and viral pathogens in 155 (7%). The annual incidence of pneumonia was 15.7 cases per 10,000 children (95% confidence interval [CI], 14.9 to 16.5), with the highest rate among children younger than 2 years of age (62.2 cases per 10,000 children; 95% CI, 57.6 to 67.1). Respiratory syncytial virus was more common among children younger than 5 years of age than among older children (37% vs. 8%), as were adenovirus (15% vs. 3%) and human metapneumovirus (15% vs. 8%). Mycoplasma pneumoniae was more common among children 5 years of age or older than among younger children (19% vs. 3%). CONCLUSIONS: The burden of hospitalization for children with community-acquired pneumonia was highest among the very young, with respiratory viruses the most commonly detected causes of pneumonia. (Funded by the Influenza Division of the National Center for Immunization and Respiratory Diseases.).


Assuntos
Hospitalização/estatística & dados numéricos , Pneumonia/epidemiologia , Adolescente , Distribuição por Idade , Criança , Pré-Escolar , Infecções Comunitárias Adquiridas/epidemiologia , Infecções Comunitárias Adquiridas/microbiologia , Feminino , Humanos , Lactente , Recém-Nascido , Pulmão/diagnóstico por imagem , Masculino , Metapneumovirus/isolamento & purificação , Mycoplasma pneumoniae/isolamento & purificação , Pneumonia/diagnóstico por imagem , Pneumonia/microbiologia , Pneumonia Viral/epidemiologia , Vigilância da População , Radiografia , Vírus Sinciciais Respiratórios/isolamento & purificação , Tennessee/epidemiologia , Utah/epidemiologia
6.
J Clin Microbiol ; 52(5): 1720-3, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24554756

RESUMO

The accurate detection and typing of high-risk human papillomavirus (HPV) are critical for cervical cancer screening. The Hybrid Capture 2 (hc2) and cobas HPV tests showed high agreement for cervical samples (94.4%, κ=0.72, n=693) and moderate agreement for vaginal samples (κ=0.62, n=108). The HPV16 and HPV18 results were highly consistent between the cobas and Linear Array tests (κ≥0.96, n=197). Three hc2-negative vaginal samples were repeatedly invalid by the cobas test due to ß-globin control failures, highlighting amplification control benefits. No cross-contamination was detected in a challenge experiment.


Assuntos
Colo do Útero/virologia , Papillomavirus Humano 16/genética , Papillomavirus Humano 18/genética , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/virologia , Vagina/virologia , Adulto , Idoso , DNA Viral/genética , Detecção Precoce de Câncer/métodos , Feminino , Genótipo , Testes de DNA para Papilomavírus Humano , Humanos , Pessoa de Meia-Idade , Esfregaço Vaginal/métodos
7.
J Clin Microbiol ; 51(8): 2662-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23761148

RESUMO

The genetic diversity of human immunodeficiency virus type 1 (HIV-1) has significant implications for diagnosis, vaccine development, and clinical management of patients. Although HIV-1 subtype B is predominant in the United States, factors such as global travel, immigration, and military deployment have the potential to increase the proportion of non-subtype B infections. Limited data are available on the prevalence and distribution of non-B HIV-1 strains in the United States. We sought to retrospectively examine the prevalence, geographic distribution, diversity, and temporal trends of HIV-1 non-B infections in samples obtained by ARUP Laboratories, a national reference laboratory, from all regions of the United States. HIV-1 pol sequences from 24,386 specimens collected from 46 states between 2004 and September 2011 for drug resistance genotyping were analyzed using the REGA HIV-1 Subtyping Tool, version 2.0. Sequences refractory to subtype determination or reported as non-subtype B by this tool were analyzed by PHYLIP version 3.5 and Simplot version 3.5.1. Non-subtype B strains accounted for 3.27% (798/24,386) of specimens. The 798 non-B specimens were received from 37 states and included 5 subtypes, 23 different circulating recombinant forms (CRFs), and 39 unique recombinant forms (URFs). The non-subtype B prevalence varied from 0% in 2004 (0/54) to 4.12% in 2011 (201/4,884). This large-scale analysis reveals that the diversity of HIV-1 in the United States is high, with multiple subtypes, CRFs, and URFs circulating. Moreover, the geographic distribution of non-B variants is widespread. Data from HIV-1 drug resistance testing have the potential to significantly enhance the surveillance of HIV-1 variants in the United States.


Assuntos
Infecções por HIV/epidemiologia , Infecções por HIV/virologia , HIV-1/classificação , HIV-1/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Análise por Conglomerados , Feminino , Variação Genética , Genótipo , HIV-1/genética , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Dados de Sequência Molecular , Filogeografia , Prevalência , Análise de Sequência de DNA , Estados Unidos/epidemiologia , Adulto Jovem , Produtos do Gene pol do Vírus da Imunodeficiência Humana/genética
8.
J Clin Microbiol ; 50(7): 2337-42, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22535983

RESUMO

Two FDA-approved (in vitro diagnostic [IVD]) hepatitis B virus (HBV) viral load assays, the manual Cobas TaqMan HBV Test for use with the High Pure System (HP) and the automated Cobas AmpliPrep/Cobas TaqMan HBV Test v2.0 (CAP/CTM), were compared to a modified (not FDA-approved) version of the HP assay by automating the DNA extraction using the Total Nucleic Acid Isolation (TNAI) kit on the Cobas AmpliPrep. On average, CAP/CTM measurements were 0.08 log IU/ml higher than HP results (n = 206), and TNAI results were 0.17 log IU/ml higher than HP results (n = 166). The limit of detection (LOD), as determined by probit analysis using dilutions of the 2nd HBV international standard, was 10.2 IU/ml for CAP/CTM. The data sets for HP and TNAI were insufficient for probit analysis; however, there was 100% detection at ≥ 5 or ≥ 10 IU/ml for TNAI and HP, respectively. Linearity was demonstrated between 60 and 2,000,000 IU/ml, with slopes between 0.95 and 0.99 and R(2) values of >0.99 for all assays. Total precision (log percent coefficient of variance [CV]) was between 0.8% and 2.1% at 4.3 log IU/ml and between 1.4% and 4.9% at 2.3 log IU/ml. Correlation of samples, reproducibility, linearity, and LOD were acceptable and similar in all assays. The CAP/CTM assay and, to a lesser extent, the TNAI assay reduced hands-on time due to automation. There were no instances of contamination detected in negative samples during the course of the study, despite testing several samples up to 9.6 log IU/ml. The incidence of false-positive negative controls in HP and CAP/CTM clinical testing was <0.5% over 6 to 7 months of testing.


Assuntos
Vírus da Hepatite B/isolamento & purificação , Hepatite B/virologia , Carga Viral/métodos , Automação/métodos , Erros de Diagnóstico/estatística & dados numéricos , Humanos , Limite de Detecção , Reprodutibilidade dos Testes
9.
J Clin Microbiol ; 48(8): 2852-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20573864

RESUMO

We evaluated the FDA-approved Roche Cobas AmpliPrep/Cobas TaqMan (CAP/CTM) HIV-1 viral load assay for sensitivity, reproducibility, linearity, HIV-1 subtype detection, and correlation to the Roche Amplicor HIV-1 monitor test, version 1.5 (Amplicor). The limit of detection calculated by probit analysis was 23.8 copies/ml using the 2nd International WHO Standard and 30.8 copies/ml using Viral Quality Assurance (VQA) standard material. Serial dilutions of six patient samples were used to determine inter- and intra-assay reproducibility and linearity, which were very good (<8% coefficient of variation [CV]; between approximately 1.7 and 7.0 log(10) copies/ml). Subtype detection was evaluated in the CAP/CTM, Amplicor, and Bayer Versant HIV-1 bDNA 3.0 (Versant) assays using a commercially available panel. Versant averaged 0.829 log(10) copies/ml lower than CAP/CTM and Amplicor averaged 0.427 log(10) copies/ml lower than CAP/CTM for the subtype panel. Correlation with samples previously tested by Amplicor was excellent (R(2) = 0.884; average difference [Amplicor value minus CAP/CTM value], 0.008 log(10) copies/ml). Of the 305 HIV samples tested, 7 samples generated CAP/CTM titers between 1.0 and 2.75 log(10) copies/ml lower than those for Amplicor. Three of these samples revealed primer and probe mismatches that could account for the discrepancies. Otherwise, the CAP/CTM assay exhibits excellent sensitivity, dynamic range, reproducibility, and correlation with Amplicor in an automated format.


Assuntos
Erros de Diagnóstico , Infecções por HIV/virologia , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/genética , Kit de Reagentes para Diagnóstico , Carga Viral/métodos , Pareamento Incorreto de Bases , Primers do DNA/genética , Genótipo , HIV-1/classificação , HIV-1/genética , Humanos , Sondas de Oligonucleotídeos/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
PLoS One ; 15(10): e0240783, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33057403

RESUMO

BACKGROUND: Understanding and monitoring the demographics of SARS-CoV-2 infection can inform strategies for prevention. Surveillance monitoring has suggested that the age distribution of people infected with SARS-CoV-2 has changed since the pandemic began, but no formal analysis has been performed. METHODS: Retrospective review of SARS-CoV-2 molecular testing results from a national reference laboratory was performed. Result distributions by age and positivity were compared between early period (March-April 2020) and late periods (June-July 2020) of the COVID-19 pandemic. Additionally, a sub-analysis compared changing age distributions between inpatients and outpatients. RESULTS: There were 277,601 test results of which 19320 (7.0%) were positive. The median age of infected people declined over time (p < 0.0005). In March-April, the median age of positive people was 40.8 years (Interquartile range (IQR): 29.0-54.1). In June-July, the median age of positive people was 35.8 years (IQR: 24.0-50.2). The positivity rate of patients under 50 increased from 6.0 to 10.6 percent and the positivity rate for those over 50 decreased from 6.3 to 5.0 percent between the early and late periods. The trend was only observed for outpatient populations. CONCLUSIONS: We confirm that there is a trend toward decreasing age among persons with laboratory-confirmed SARS-CoV-2 infection, but that these trends seem to be specific to the outpatient population. Overall, this suggests that observed age-related trends are driven by changes in testing patterns rather than true changes in the epidemiology of SARS-CoV-2 infection. This calls for caution in interpretation of routine surveillance data until testing patterns stabilize.


Assuntos
Técnicas de Laboratório Clínico/estatística & dados numéricos , Infecções por Coronavirus/epidemiologia , Monitoramento Epidemiológico , Pneumonia Viral/epidemiologia , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , COVID-19 , Teste para COVID-19 , Criança , Pré-Escolar , Técnicas de Laboratório Clínico/normas , Infecções por Coronavirus/diagnóstico , Humanos , Lactente , Pessoa de Meia-Idade , Pandemias , Estados Unidos
11.
Viruses ; 12(2)2020 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-32033422

RESUMO

Infections with HIV-1 group M subtype B viruses account for the majority of the HIV epidemic in the Western world. Phylogeographic studies have placed the introduction of subtype B in the United States in New York around 1970, where it grew into a major source of spread. Currently, it is estimated that over one million people are living with HIV in the US and that most are infected with subtype B variants. Here, we aim to identify the drivers of HIV-1 subtype B dispersal in the United States by analyzing a collection of 23,588 pol sequences, collected for drug resistance testing from 45 states during 2004-2011. To this end, we introduce a workflow to reduce this large collection of data to more computationally-manageable sample sizes and apply the BEAST framework to test which covariates associate with the spread of HIV-1 across state borders. Our results show that we are able to consistently identify certain predictors of spread under reasonable run times across datasets of up to 10,000 sequences. However, the general lack of phylogenetic structure and the high uncertainty associated with HIV trees make it difficult to interpret the epidemiological relevance of the drivers of spread we are able to identify. While the workflow we present here could be applied to other virus datasets of a similar scale, the characteristic star-like shape of HIV-1 phylogenies poses a serious obstacle to reconstructing a detailed evolutionary and spatial history for HIV-1 subtype B in the US.


Assuntos
Infecções por HIV/epidemiologia , Infecções por HIV/transmissão , Soropositividade para HIV/epidemiologia , HIV-1/classificação , Teorema de Bayes , Infecções por HIV/virologia , Soropositividade para HIV/virologia , HIV-1/genética , Humanos , Masculino , Filogenia , Filogeografia , Minorias Sexuais e de Gênero , Estados Unidos/epidemiologia
12.
J Clin Microbiol ; 47(9): 2872-8, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19625475

RESUMO

The accurate and sensitive measurement of hepatitis C virus (HCV) RNA is essential for the clinical management and treatment of infected patients and as a research tool for studying the biology of HCV infection. We evaluated the linearity, reproducibility, precision, limit of detection, and concordance of viral genotype quantitation of the Abbott investigational use only RealTime HCV (RealTime) assay using the Abbott m2000 platform and compared the results to those of the Roche TaqMan Analyte-Specific Reagent (TaqMan) and Bayer Versant HCV bDNA 3.0 assay. Comparison of 216 samples analyzed by RealTime and TaqMan assays produced the following Deming regression equation: RealTime = 0.940 (TaqMan) + 0.175 log(10) HCV RNA IU/ml. The average difference between the assays was 0.143 log(10) RNA IU/ml and was consistent across RealTime's dynamic range of nearly 7 log(10) HCV RNA IU/ml. There was no significant difference between genotypes among these samples. The limit of detection using eight replicates of the World Health Organization HCV standard was determined to be 7.74 HCV RNA IU/ml by probit analysis. Replicate measurements of commercial genotype panels were significantly higher than TaqMan measurements for most samples and showed that the RealTime assay is able to detect all genotypes with no bias. Additionally, we showed that the amplicon generated by the widely used Roche COBAS Amplicor Hepatitis C Virus Test, version 2.0, can act as a template in the RealTime assay, but potential cross-contamination could be mitigated by treatment with uracil-N-glycosylase. In conclusion, the RealTime assay accurately measured HCV viral loads over a broad dynamic range, with no significant genotype bias.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/virologia , Técnicas de Diagnóstico Molecular/métodos , Kit de Reagentes para Diagnóstico , Carga Viral/métodos , Genótipo , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Virol Methods ; 156(1-2): 124-8, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19061916

RESUMO

A multiplex real-time RT-PCR assay that detects influenza A, influenza B and respiratory syncytial virus (RSV) using the MGB Alert Influenza A&B/RSV Detection Reagent RUO (Nanogen, San Diego, CA) was developed. The Nanogen detection reagents consist of PCR primers and minor groove binder-conjugated hybridization probes for each virus and an internal control. Virus typing was determined by post-PCR melt curve analysis. A non-competitive armored RNA internal control was co-extracted with each sample to monitor nucleic acid extraction and RT-PCR. The assay was evaluated using a collection of culture, DFA and RT-PCR (Hexaplex, Prodesse, Waukesha, WI) positive and negative samples. The real-time multiplex assay detected 236 of 237 positive specimens for a 99% correlation. Of 30 Hexaplex negative samples tested, the multiplex real-time assay detected an additional 7 positives confirmed using additional PCR assays. Melt curve analysis for each virus produced average melting peaks of 60.4 degrees C, 66.7 degrees C and 69.4 degrees C for influenza A, influenza B and RSV respectively. Sequence analysis of 7 influenza A samples producing aberrant melt curves, confirmed the presence of a single nucleotide polymorphism beneath the influenza A probe. The limit of detection of each virus in 4 different sample types was measured to be between 7 and 806 copies. Overall, the multiplexed real-time RT-PCR assay was sensitive, robust and easy to use.


Assuntos
Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Vírus Sincicial Respiratório Humano/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Primers do DNA , Humanos , Indicadores e Reagentes/análise , Vírus da Influenza A/genética , Vírus da Influenza B/genética , RNA Viral/análise , Vírus Sincicial Respiratório Humano/genética , Sensibilidade e Especificidade
14.
Indian J Crit Care Med ; 12(4): 145-52, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19742269

RESUMO

BACKGROUND: Herpes simplex-1 virus (HSV-1) reactivation in the respiratory tract is common in intensive care unit (ICU) patients. However, susceptible ICU populations are poorly defined. Clinical recognition of HSV infection of the respiratory tract is difficult and the impact of such reactivation is not understood. MATERIALS AND METHODS: A retrospective analysis of HSV-1 positive patients encountered over a 5-year period at a multispecialty ICU was carried out. HSV-1 was identified in respiratory secretions using a qualitative polymerase chain reaction (PCR) technique. Patient charts were reviewed for clinical features that would typify HSV-1 respiratory involvement, and the morbidity and mortality risks found with HSV-1 respiratory involvement. RESULTS: A review of 48 HSV-1 positive ICU patients showed that patients reactivating HSV in the respiratory tract fell into one of the three categories: (1) septic elderly patients with and without ARDS, (2) immunosuppressed patients, especially those receiving high-dose steroids, and (3) post-thoracotomy patients. Abnormalities suggestive of HSV-1 reactivation in the respiratory tract included, haemorrhagic or excessive respiratory secretions, concomitant orofacial herpes (42%), and bronchoscopic abnormalities (hemorrhagic ulcers and mucosal friability) (83%). Twenty eight percent of the HSV-1 infected patients experienced postextubation stridor. HSV-1 reactivation was associated with extended ventilator stays, significant mortality (42%), and ventilator-associated pneumonias (52%). CONCLUSIONS: Identification of susceptible populations and definition of clinical features of HSV-1 related respiratory disease can enable diagnosis of HSV-1 infection in ICU patients. Although detection by a PCR technique can rapidly diagnose HSV-1 reactivation, prospective studies are required to clarify HSV disease versus mere shedding, and understand the impact of HSV-1 reactivation in hospitalized patients.

15.
Methods Enzymol ; 421: 21-34, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17352912

RESUMO

Essential genes are identified in duplicated regions of the bacterial chromosome. Transposition of a vector that forms operon fusions into a strain carrying a chromosomal duplication allows insertion of the transposon into essential genes because a second copy of the essential gene is present. When the duplication is allowed to segregate, only the segregant that carries the copy of the intact essential gene survives. The transposon insertion in the essential gene is maintained only in the duplication derivatives. A technique is described that uses a Tn10 derivative, Tn10dTc-araC(+), which contains a cloned copy of the Escherichia coli araC(+) gene, as a portable region of homology to generate large duplications of the Salmonella chromosome. The duplication is maintained in the population by growth in the presence of tetracycline. When the lac operon fusion vector, MudJ, is transposed into the duplicated region, removal of tetracycline from the growth media allows segregation of the duplication yielding (Ara(-)) haploid segregants which appear as red colonies or as red/white (Ara(-/+)) sectoring colonies on TTC arabinose indicator plates. However, if the insertion is in an essential gene, only segregants that lose the MudJ insertion in the essential gene survive. In this case, selection for the insertion in the essential gene yields solid white (Ara(+)) colonies in the absence of tetracycline. While the specific design presented uses Mud transposon insertions to generate lac operon (transcriptional) and lacZ gene (translational) fusions to essential genes, this technique can be used to generate transposon insertions of any kind into essential genes.


Assuntos
Genes Bacterianos , Genes Essenciais , Cromossomos Bacterianos/genética
16.
Diagn Microbiol Infect Dis ; 58(3): 333-5, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17376631

RESUMO

Clinicians use molecular tests to detect Herpesviridae from blood without fully appreciating limitations of testing. Studies are needed to enhance our understanding of the impact of Herpesviridae latency on molecular testing. We retrospectively performed quantitative Epstein-Barr virus (EBV) on sera from patients between the ages of 1 and 30 who demonstrated serologic evidence of acute EBV (n = 50) or remote EBV (n = 50) infection. Epstein-Barr virus DNA was detected in 70% of acutely infected and 4% of remotely infected patients. Sera from acutely infected patients had higher EBV copy number than convalescent sera. Our results suggest that serology should be performed as the initial diagnostic test for acute EBV. The role for polymerase chain reaction in immunocompromised patients with impaired antibody responses or as a 2nd-line diagnostic test when serologic results are equivocal deserves further study.


Assuntos
Infecções por Vírus Epstein-Barr/diagnóstico , Herpesvirus Humano 4/genética , Reação em Cadeia da Polimerase , Adolescente , Adulto , Criança , Pré-Escolar , DNA Viral/sangue , Infecções por Vírus Epstein-Barr/virologia , Feminino , Herpesvirus Humano 4/isolamento & purificação , Humanos , Masculino , Estudos Retrospectivos , Testes Sorológicos , Soro/virologia
17.
J Clin Virol ; 90: 26-31, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28324789

RESUMO

BACKGROUND: HCV genotyping remains a critical tool for guiding initiation of therapy and selecting the most appropriate treatment regimen. Current commercial genotyping assays may have difficulty identifying 1a, 1b and genotype 6. OBJECTIVE: To evaluate the concordance for identifying 1a, 1b, and genotype 6 between two methods: the PLUS assay and core/NS5B sequencing. STUDY DESIGN: This study included 236 plasma and serum samples previously genotyped by core/NS5B sequencing. Of these, 25 samples were also previously tested by the Abbott RealTime HCV GT II Research Use Only (RUO) assay and yielded ambiguous results. The remaining 211 samples were routine genotype 1 (n=169) and genotype 6 (n=42). Genotypes obtained from sequence data were determined using a laboratory-developed HCV sequence analysis tool and the NCBI non-redundant database. RESULTS: Agreement between the PLUS assay and core/NS5B sequencing for genotype 1 samples was 95.8% (162/169), with 96% (127/132) and 95% (35/37) agreement for 1a and 1b samples respectively. PLUS results agreed with core/NS5B sequencing for 83% (35/42) of unselected genotype 6 samples, with the remaining seven "not detected" by the PLUS assay. Among the 25 samples with ambiguous GT II results, 15 were concordant by PLUS and core/NS5B sequencing, nine were not detected by PLUS, and one sample had an internal control failure. CONCLUSIONS: The PLUS assay is an automated method that identifies 1a, 1b and genotype 6 with good agreement with gold-standard core/NS5B sequencing and can aid in the resolution of certain genotype samples with ambiguous GT II results.


Assuntos
Genótipo , Técnicas de Genotipagem/métodos , Hepacivirus/classificação , Hepacivirus/genética , Hepatite C/virologia , Proteínas do Core Viral/genética , Proteínas não Estruturais Virais/genética , Automação Laboratorial/métodos , Hepacivirus/isolamento & purificação
18.
Pediatr Infect Dis J ; 24(6): 546-50, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15933567

RESUMO

BACKGROUND: Enterovirus (EV) infections commonly cause fever in infants younger than 90 days of age. The polymerase chain reaction (PCR) has improved our ability to diagnose EV infections. OBJECTIVE: To evaluate the utility of blood and cerebrospinal fluid (CSF) specimens for the diagnosis of EV infections by PCR and to describe a large cohort of EV-infected infants. DESIGN/METHODS: Febrile infants younger than 90 days of age evaluated for sepsis at Primary Children's Medical Center in Salt Lake City, UT, were enrolled in a prospective study designed to identify viral infections from December 1996 to June 2002. All patients had bacterial cultures of blood, urine and CSF. Testing for EV was performed by PCR and/or viral cultures. Patients who were positive for EV were identified for this study. RESULTS: Of 1779 febrile infants enrolled, 1061 had EV testing and 214 (20%) were EV-positive. EV infections were diagnosed by PCR of blood, CSF or both in 93% of infants. PCR testing was positive in blood in 57%, and blood was the only positive specimen for 22% of EV infected infants. PCR of CSF was positive in 74%. The mean age of infants with EV infection was 33 days, with 18% younger than 14 days and 5% younger than 7 days. Fifty percent of EV-positive infants had CSF pleocytosis. Of EV PCR-positive infants, 91% were admitted, and 2% required intensive care. Possible serious EV disease was diagnosed in <1%, and there were no deaths. Twelve infants (5.6%) had concomitant urinary tract infection, and 3 (1%) had bacteremia. CONCLUSIONS: EV infections are common in febrile infants younger than 90 days. Blood and CSF are equally likely to yield positive results by PCR, but the combination of both specimens improved the diagnostic yield.


Assuntos
Infecções por Enterovirus/diagnóstico , Enterovirus/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Sangue/virologia , Líquido Cefalorraquidiano/citologia , Líquido Cefalorraquidiano/virologia , Enterovirus/genética , Infecções por Enterovirus/fisiopatologia , Infecções por Enterovirus/virologia , Febre/virologia , Humanos , Lactente , Recém-Nascido , Viremia/diagnóstico , Viremia/virologia , Cultura de Vírus
19.
J Clin Virol ; 65: 54-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25766989

RESUMO

BACKGROUND: Accurate HCV RNA measurement is required for monitoring treatment. Underquantification has been reported with some genotypes, particularly genotype 4, using version 1 of the Roche COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HCV Test. OBJECTIVES: Compare the viral loads of clinical specimens representing diverse genotypes from across the United States using versions 1 (V1) and 2 (V2) of the Roche COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HCV Test. Assess the frequency of nt145 and nt165 variants in the 5' UTR associated with detection failures and underquantification in a large clinical sample database. STUDY DESIGN: Three hundred archived clinical samples were measured using V1 and V2. Bland-Altman analysis was performed on log-transformed results and compared by genotype. The frequencies of nt145 and nt165 variants from 15,817 sequences were calculated. RESULTS: On average, V2 results were 0.16 logIU/mL lower than V1 results. The average genotype 4 sample was 0.08 logIU/mL higher in V1 than V2. The largest individual sample differences were -2.10 (genotype 2b) and 1.57 (genotype 2a) logIU/mL. For genotype 4 samples, the greatest underquantification by V1 was 1.46 logIU/mL. There were 13 (0.082%) variants at nt145 and 24 variants at nt165 (0.152%), including one sequence with variants at both positions (0.0063%). CONCLUSIONS: Genotype 4 samples from the U.S. are rarely underquantified and not disproportionately so compared to other genotypes using the COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HCV Tests. Variants at the nt145 and nt165 positions are uncommon in the U.S. and double variants are exceedingly rare. Underquantification of HCV samples with the V1 assay is likely a very rare occurrence in U.S.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/virologia , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/sangue , Carga Viral , Regiões 5' não Traduzidas , Genótipo , Hepacivirus/genética , Humanos , Testes Imunológicos/métodos , RNA Viral/genética , Sensibilidade e Especificidade , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA