Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Zhonghua Wai Ke Za Zhi ; 59(12): 987-993, 2021 Dec 01.
Artigo em Zh | MEDLINE | ID: mdl-34839613

RESUMO

Objective: To investigate the long-term efficacy and safety of alternating double balloon occlusion combined with intra-aneurysm injection of human fibrin binder in the endovascular repair of ruptured abdominal aortic aneurysm (rAAA). Methods: The clinical data of 28 patients with rAAA admitted to Department of Vascular Surgery, the Fourth Affiliated Hospital of Guangxi Medical University from January 2015 to December 2019 were retrospectively analyzed. There were 23 males and 5 females, aged (62±5) years (range: 46 to 88 years).The maximum diameter of the tumors was (65.2±10.5) mm (range: 47.3 to 100.5 mm), all of which were subrenal rAAA. The intraoperative EVAR for abdominal aortic aneurysm was successfully performed under the emergency green channel procedure, and this surgery was assisted used the double balloon occlusion technique in aorta of inferior renal and superior renalcombined with intraoperative human fibrin binder injection technique. Observation indexes included: patients with preoperative preparation, operation time, hospitalization days, surgical treatment success rate and the incidence of postoperative complications, and aortic stent form during the follow-up period, the incidence of leakage, branch stents patency rate and infection rates. Results: The preoperative preparation time of 28 patients was (45.5±8.5) minutes (range:20 to 100 minutes). The operation time was (100.0±15.5) minutes (range:85 to 210 minutes), the ICU stay time was (7±2) days(range:1 to 17 days). The length of hospitalization was (13.5±2.5) days(range:5 to 43 days). The success rate of surgical treatment was 92.9% (26/28). Two patients died, 1 case died of postoperative multifocal lacunar cerebral infarction and massive gastrointestinal hemorrhage, and another elderly patient (84 years old) died of massive abdominal fluid due to preoperative abdominal aortic aneurysm rupture, postoperative complicated with significant abdominal compartment syndrome, and secondary multiple organ failure. Balloon occlusion of the upper renal aorta took (13±2)minutes (range:12 to 30 minutes). The intraoperative injection of fibrin adhesive was (14±2) ml(range:6 to 28 ml) in 22 cases. The incidence of major postoperative complications was 57.1% (16/28). Among the 26 patients who survived the surgery, 69.2% (18/26) completed the 3-year follow-up, and the follow-up time was (30±3) months(range:13 to 36 months). During the follow-up, the aortic stent was in good shape without obvious displacement. The incidence of leakage within 6 months after the operation was 10.7% (3/28), and there was no internal leakage in the patients who were followed up for 36 months after the operation. The patency rate of renal artery and iliac artery branch stents was 16/18. The incidence of stent infection was 7.7% (2/26), 1 case occurred at 1 month and another case at 6 months, respectively. All patients recovered after prolonged intensive anti-infection therapy. Conclusions: Under the standard emergency treatment process, the double balloon alternating occlusion technique combined with the intra-aneurysm injection of human fibrin adhesive technique can assist the successful completion of the endovascular repair of rAAA, effectively improve the success rate of treatment for patients, and reduce the incidence of postoperative leakage and serious complications. The mid-term and long-term results of EVAR for rAAA are good, safe and reliable.


Assuntos
Aneurisma da Aorta Abdominal , Oclusão com Balão , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/cirurgia , China , Feminino , Fibrina , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Stents , Resultado do Tratamento
2.
Phys Rev Lett ; 122(1): 010503, 2019 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-31012688

RESUMO

We experimentally realize a universal set of single-bit and two-bit geometric quantum gates by adiabatically controlling solid-state spins in a diamond defect. Compared with the nonadiabatic approach, the adiabatic scheme for geometric quantum computation offers a unique advantage of inherent robustness to parameter variations, which is explicitly demonstrated in our experiment by showing that the single-bit gates remain unchanged when the driving field amplitude varies by a factor of 2 or the detuning fluctuates in a range comparable to the inverse of the gate time. The reported adiabatic control technique and its convenient implementation offer a paradigm for achieving quantum computation through robust geometric quantum gates, which is important for quantum information systems with parameter-fluctuation noise such as those from the inhomogeneous coupling or the spectral diffusion.

3.
Zhonghua Yi Xue Za Zhi ; 98(12): 930-934, 2018 Mar 27.
Artigo em Zh | MEDLINE | ID: mdl-29665668

RESUMO

Objective: To discuss the feasibility, effect and safety of lower abdominal aorta balloon occlusion technique by ultrasound guiding during caesarean section in patients with pernicious placenta previa. Methods: The clinical data of 40 patients with pernicious placenta previa complicated with placenta accreta from January 2015 to August 2017 in Liuzhou workers hospital were analyzed retrospectively. The study group included 20 cases, which were operated in the way of cesarean section combined lower abdominal aorta balloon occlusion technique by ultrasound guiding, while the control group also included 20 cases, which were operated in the way of the conventional cesarean section without balloon occlusion technique. The bleeding amount, blood transfusion volume, operative total time, hysterectomy and complications of the two groups were compared. Results: The bleeding amount and blood transfusion volume in study group were(850±100)ml and (400±50)ml, which were lower than that of the control group[(2 500±230)ml and (1 500±100)ml], the difference was statistically significant(t=35.624, 16.523, all P<0.05). In addition, the hysterectomy rate in study group was 5%, which was lower than that in the control group(30%), the difference was statistically significant(χ2=8.672, P<0.05). And the total time of operation was (2.0±0.5)h in the study group, which was shorter than that in the control group[(3.5±0.4)h]. The difference was statistically significant(t=11.362, P<0.05). No postoperative complications took place in the study group.The blood pressure, heart rate and blood oxygen fluctuated significantly, and the postoperative renal function was significantly reduced in the control group. Conclusions: The lower abdominal aorta balloon occlusion technique by ultrasound guiding during a caesarean section in patients with pernicious placenta previa can effectively control the bleeding during operation, and preserve reproductive function to the utmost degree.Therefore, the technique is safe, feasible, convenient and cheaper, and worthy of being widely applied in clinic.


Assuntos
Oclusão com Balão , Aorta Abdominal , Perda Sanguínea Cirúrgica , Cesárea , Feminino , Humanos , Histerectomia , Placenta Prévia , Hemorragia Pós-Parto , Gravidez , Estudos Retrospectivos
4.
Phys Rev Lett ; 111(5): 050405, 2013 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-23952373

RESUMO

We report the first experimental demonstration of distillation of quantum nonlocality, confirming the recent theoretical protocol [Phys. Rev. Lett. 102, 120401 (2009)]. Quantum nonlocality is described by a correlation box with binary inputs and outputs, and the nonlocal boxes are realized through appropriate measurements on polarization entangled photon pairs. We demonstrate that nonlocality is amplified by connecting two nonlocal boxes into a composite one through local operations and four-photon measurements.

5.
Phys Rev Lett ; 109(15): 150401, 2012 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-23102277

RESUMO

We report the first state-independent experimental test of quantum contextuality on a single photonic qutrit (three-dimensional system), based on a recent theoretical proposal [Phys. Rev. Lett. 108, 030402 (2012)]. Our experiment spotlights quantum contextuality in its most basic form, in a way that is independent of either the state or the tensor product structure of the system.

6.
Phys Rev Lett ; 110(7): 078902, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25166420
7.
Sci Rep ; 6: 29453, 2016 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-27404561

RESUMO

To construct a quantum network with many end users, it is critical to have a cost-efficient way to distribute entanglement over different network ends. We demonstrate an entanglement access network, where the expensive resource, the entangled photon source at the telecom wavelength and the core communication channel, is shared by many end users. Using this cost-efficient entanglement access network, we report experimental demonstration of a secure multiparty computation protocol, the privacy-preserving secure sum problem, based on the network quantum cryptography.

8.
Nat Commun ; 7: 11736, 2016 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-27240553

RESUMO

With the recent development of optomechanics, the vibration in solids, involving collective motion of trillions of atoms, gradually enters into the realm of quantum control. Here, building on the recent remarkable progress in optical control of motional states of diamonds, we report an experimental demonstration of quantum teleportation from light beams to vibrational states of a macroscopic diamond under ambient conditions. Through quantum process tomography, we demonstrate average teleportation fidelity (90.6±1.0)%, clearly exceeding the classical limit of 2/3. The experiment pushes the target of quantum teleportation to the biggest object so far, with interesting implications for optomechanical quantum control and quantum information science.

9.
Sci Rep ; 5: 12452, 2015 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-26197928

RESUMO

The router is a key element for a network. We describe a scheme to realize genuine quantum routing of single-photon pulses based on cascading of conditional quantum gates in a Mach-Zehnder interferometer and report a proof-of-principle experiment for its demonstration using linear optics quantum gates. The polarization of the control photon routes in a coherent way the path of the signal photon while preserving the qubit state of the signal photon represented by its polarization. We demonstrate quantum nature of this router by showing entanglement generated between the initially unentangled control and signal photons, and confirm that the qubit state of the signal photon is well preserved by the router through quantum process tomography.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA