Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Emerg Med ; 38(1): 122-126, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31349906

RESUMO

OBJECTIVE: The purpose of this pilot study was to investigate whether use of a guidewire improves successful placement of ultrasound-guided peripheral IVs (PIV) in difficult intravenous access patients in the emergency department (ED). METHODS: This was an unblinded, prospective, randomized trial performed by emergency medicine (EM) clinicians at a single academic ED. Eligible participants were randomized to ultrasound-guided PIV placement with or without the use of a guidewire. PIV access was obtained using the Accucath™ 20 gauge × 5.7 cm catheters by way of deployment or non-deployment of the guidewire. Primary outcome measure was first-pass success rate and secondary outcomes included number of attempts, complication rates, and clinician reported ease of insertion. RESULTS: Seventy patients were enrolled and 69 were included in the final analysis. Thirty-four participants were randomized to use of guidewire and 35 to no guidewire. First-pass success rates were similar with and without guidewire use, 47.1% vs. 45.7%, (p = 0.9). There were no differences found in median number of attempts between the two techniques, 2 (IQR 1-2) vs 2 (IQR 1-2), (p = 0.60). The complication rates were similar, 15% vs. 29% (p = 0.25). Clinicians reported no difference in ease of insertion between methods on a 5-point Likert Scale, mean 2.6 vs 2.7 (p = 0.76). DISCUSSION: In this pilot study comparing ultrasound-guided PIV placement in ED patients using an integrated guidewire versus no guidewire, there was no significant difference in first-pass success, number of attempts, or complication rates. This study provides preliminary data for further investigations.


Assuntos
Cateterismo Periférico/métodos , Serviço Hospitalar de Emergência , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Fatores de Tempo , Ultrassonografia
3.
West J Emerg Med ; 21(4): 1022-1028, 2020 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-32726278

RESUMO

INTRODUCTION: Tricuspid annular plane systolic excursion (TAPSE) is an established echocardiographic marker of right ventricular (RV) systolic function. The objective of this study was to evaluate whether emergency clinicians can visually estimate RV function using TAPSE in a set of video clips compared to a reference standard M-mode measurement. METHODS: Emergency clinicians were shown a five-minute educational video on TAPSE. Participants then viewed 20 apical four-chamber point-of-care ultrasound (POCUS) echocardiography clips and recorded their estimate of TAPSE distance in centimeters (cm), as well as whether TAPSE was normal (>1.9 cm), borderline (1.5-1.9 cm), or abnormal (<1.5 cm). We calculated sensitivity, specificity, and overall accuracy of visual TAPSE categorization using M-mode measurement as the criterion standard. Participants also reported their comfort with assessing TAPSE on a five-point Likert scale before and after participation in the study. RESULTS: Among 70 emergency clinicians, including 20 postgraduate year 1-4 residents, 22 attending physicians, and 28 physician assistants (PA), the pooled sensitivity and specificity for visual assessment of TAPSE was 88.6% (95% confidence interval, 85.4-91.7%) and 81.6% (95% CI, 78.2-84.4%), respectively. The sensitivity and specificity for the clips in which the measured TAPSE was <1.5 cm or >1.9 cm was 91.4% (95% CI, 88.4-94.3%) and 90.8% (95% CI, 87.7-93.9%), respectively. There was no significant difference in sensitivity (p = 0.27) or specificity (p = 0.55) between resident and attending physicians or between physicians and PAs (p = 0.17 and p = 0.81). Median self-reported comfort with TAPSE assessment increased from 1 (interquartile range [IQR] 1-2) to 3 (IQR 3-4) points after participation in the study. CONCLUSION: A wide range of emergency clinicians demonstrated fair accuracy for visual estimation of TAPSE on previously recorded POCUS echocardiography video clips. These findings should be considered hypothesis generating and warrant validation in larger, prospective studies.


Assuntos
Ecocardiografia , Serviços Médicos de Emergência , Valva Tricúspide/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico , Função Ventricular Direita/fisiologia , Ecocardiografia/métodos , Ecocardiografia/normas , Serviços Médicos de Emergência/métodos , Serviços Médicos de Emergência/normas , Humanos , Testes Imediatos , Estudos Prospectivos , Sensibilidade e Especificidade , Valva Tricúspide/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia
4.
Cureus ; 9(4): e1129, 2017 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-28473947

RESUMO

Ultrasound use is rapidly increasing in clinical care and as an educational modality. While there is widespread interest in training health-care professionals to incorporate ultrasound into their daily practice, there are few resources available to guide instructors in the design of impactful and efficient training sessions. We present 10 practical strategies to optimize the educational value of ultrasound workshops for any audience.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA