Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Chem Chem Phys ; 17(1): 521-9, 2015 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-25407850

RESUMO

The physicochemical state of a catalyst is a key factor in determining both activity and selectivity; however these materials are often not structurally or compositionally homogeneous. Here we report on the 3-dimensional imaging of an industrial catalyst, Mo-promoted colloidal Pt supported on carbon. The distribution of both the active Pt species and Mo promoter have been mapped over a single particle of catalyst using microfocus X-ray fluorescence computed tomography. X-ray absorption near edge spectroscopy (XANES) and extended X-ray absorption fine structure revealed a mixed local coordination environment, including the presence of both metallic Pt clusters and Pt chloride species, but also no direct interaction between the catalyst and Mo promoter. We also report on the benefits of scanning µ-XANES computed tomography for chemical imaging, allowing for 2- and 3-dimensional mapping of the local electronic and geometric environment, in this instance for both the Pt catalyst and Mo promoter throughout the catalyst particle.

2.
Rev Sci Instrum ; 88(1): 015101, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147643

RESUMO

The complex tribochemical nature of lubricated tribological contacts is inaccessible in real time without altering their initial state. To overcome this issue, a new design of a pin-on-disc tribological apparatus was developed and combined with synchrotron X-ray absorption spectroscopy (XAS). Using the designed apparatus, it is possible to study in situ the transient decomposition reactions of various oil additives on different surfaces under a wide range of realistic operating conditions of contact pressure (1.0-3.0 GPa), temperature (25-120 °C), and sliding speed (30-3000 rpm or 0.15-15 m/s). To test the apparatus, several tribological tests were performed at different shearing times ranging from 2.5 to 60 min. These tests were carried out under helium atmosphere at a temperature of 80 °C, contact pressure of 2.2 GPa, and sliding speed of 50 rpm. The XAS experiments indicate that the zinc dialkyldithiophosphate antiwear additive decomposes in the oil to form a tribofilm on the iron surface at different reaction kinetics from the ones of the thermal film. The tribofilm composition evolves much faster than the one of the thermal film, which confirms that the formation of the tribofilm is a thermally activated process similar to the one of the thermal film but accelerated by shear. Furthermore, the results indicate that the sulfur of the formed film, whether a tribofilm or a thermal film, appears initially in the form of sulfate, with some sulfide, which under heat or shear is reduced into mainly sulfide.

3.
Metallomics ; 6(4): 774-82, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24804302

RESUMO

Large-scale Synchrotron Rapid Scanning X-ray Fluorescence (SRS-XRF) elemental mapping and X-ray absorption spectroscopy are applied here to fossil leaf material from the 50 Mya Green River Formation (USA) in order to improve our understanding of the chemistry of fossilized plant remains. SRS-XRF of fossilized animals has previously shown that bioaccumulated trace metals and sulfur compounds may be preserved in their original distributions and these elements can also act as biomarkers for specific biosynthetic pathways. Similar spatially resolved chemical data for fossilized plants is sparsely represented in the literature despite the multitude of other chemical studies performed. Here, synchrotron data from multiple specimens consistently show that fossil leaves possess chemical inventories consisting of organometallic and organosulfur compounds that: (1) map discretely within the fossils, (2) resolve fine scale biological structures, and (3) are distinct from embedding sedimentary matrices. Additionally, the chemical distributions in fossil leaves are directly comparable to those of extant leaves. This evidence strongly suggests that a significant fraction of the chemical inventory of the examined fossil leaf material is derived from the living organisms and that original bioaccumulated elements have been preserved in situ for 50 million years. Chemical information of this kind has so far been unknown for fossilized plants and could for the first time allow the metallome of extinct flora to be studied.


Assuntos
Fósseis , Metais/análise , Compostos Organometálicos/análise , Folhas de Planta/química , Plantas/química , Compostos de Enxofre/análise , Espectrometria por Raios X , Síncrotrons , Espectroscopia por Absorção de Raios X
4.
Rev Sci Instrum ; 84(8): 083702, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24007068

RESUMO

Here we present a general alignment algorithm for an edge illumination x-ray phase contrast imaging system, which is used with the laboratory systems developed at UCL. It has the flexibility to be used with all current mask designs, and could also be applied to future synchrotron based systems. The algorithm has proved to be robust experimentally, and can be used for the automatization of future commercial systems through automatic alignment and alignment correction.


Assuntos
Laboratórios , Iluminação/instrumentação , Radiografia/instrumentação , Automação , Raios X
5.
Med Phys ; 40(9): 090701, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24007133

RESUMO

PURPOSE: To provide an x-ray phase contrast imaging (XPCI) method working with conventional sources that could be readily translated into clinical practice. XPCI shows potential in synchrotron studies but attempts at translating it for use with conventional sources are subject to limitations in terms of field of view, stability, exposure time, and possibly most importantly, delivered dose. METHODS: Following the adaptation of our "edge-illumination" XPCI technique for use with conventional x-ray sources through the use of x-ray masks, the authors have further modified the design of such masks to allow further reducing the dose delivered to the sample without affecting the phase sensitivity of the method. RESULTS: The authors have built a prototype based on the new mask design and used it to image ex vivo breast tissue samples containing malignant lesions. The authors compared images acquired with this prototype to those obtained with a conventional system. The authors demonstrate and quantify image improvements, especially in terms of microcalcification detection. On calcifications detected also by the conventional system, the authors measure contrast increases from five to nine fold; calcifications and other features were also detected which are completely invisible in the conventional image. Dose measurements confirmed that the above enhancements were achieved while delivering doses compatible with clinical practice. CONCLUSIONS: The authors obtained phase-related image enhancements in mammography by means of a system built with components available off-the-shelf that operates under exposure time and dose conditions compatible with clinical practice. This opens the way to a straightforward translation of phase enhanced imaging methods into clinical practice.


Assuntos
Mamografia/métodos , Doses de Radiação , Humanos , Raios X
6.
Rev Sci Instrum ; 82(7): 073702, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21806184

RESUMO

We discuss the problem of signal diffusion among neighbouring pixels in x-ray phase contrast imaging (XPCi) specifically for coded-aperture (CA) XPCi, but many of the discussed observations are directly transferable to other XPCi modalities. CA XPCi exploits the principle of pixel edge illumination by means of two CA masks. The first mask, placed in contact with the detector, creates insensitive regions between adjacent pixels; the second one, placed immediately before the sample, creates individual beams impinging on the boundaries between sensitive and insensitive regions on the detector, as created by the detector mask. In this way, edge illumination is achieved for all pixels of an area detector illuminated by a divergent and polychromatic beam generated by a conventional source. As the detector mask redefines the resolution properties of the detector, sample dithering can be used to effectively increase the system spatial resolution, without having to apply any post-processing procedure (e.g., deconvolution). This however creates artifacts in the form of secondary fringes (which have nothing to do with phase-related secondary fringes) if there is signal diffusion between adjacent pixels. In non-dithered images, signal diffusion between adjacent pixels causes a reduction in image contrast. This effect is investigated both theoretically and experimentally, and its direct implications on image quality are discussed. The interplay with the sample positioning with respect to the detector pixel matrix, which also has an effect on the obtained image contrast, is also discussed.


Assuntos
Dispositivos Ópticos , Difusão , Polietileno/química , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA